• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1028
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 88
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Análise da distribuição das tensões através de prótese fixa implanto-suportada e dento-implanto-suportada em hemi-mandíbulas de canis familiaris mediante o método de interferometria holográfica de dupla exposição / Stress analysis of tooth-implant and implant supported prosthesis in dog mandibles. Holographic interferometry double exposition method

Rodriguez, José Eduardo Chorres 20 September 2005 (has links)
Este estudo objetivou pesquisar a distribuição das tensões através de próteses fixas implanto-suportadas e dento-implanto-suportadas em hemi-mandíbulas de canis familiaris mediante o método de interferometria holográfica de dupla exposição. Três cães foram selecionados e colocados três implantes em cada um deles (hemi-mandíbula direita: um implante e na hemi-mandíbula esquerda: dois implantes). Após a espera de dois meses, os dois tipos de próteses foram fixados sobre os implantes e os animais sacrificados. A seguir, as hemi -mandíbulas foram extraídas e fixadas no dispositivo especialmente desenhado para tal fim (CAMPOS, 2001). Todo o sistema foi colocado sobre uma mesa holográf ica e carga estática foi aplicada sobre três posições previamente estabelecidas nas próteses (sobre o pilar anterior, ponto médio da barra e pilar posterior). 18 hologramas foram obtidos mediante a técnica holográfica. A análise dos hologramas revelou que de forma geral, as hemi-mandíbulas com próteses dento-implanto-suportadas sofreram maior tensão quando comparadas com as hemi-mandíbulas com próteses implanto-suportadas. Em relação às próteses, as implanto-suportadas foram aquelas que melhor distribuíram os esforços quando comparadas com as dento-implanto-suportadas. / The aim of this study was to investigate the stress distribution of tooth-implant and implant supported prosthesis in dog mandibles by means of holographic interferometry double exposition method. Three mongrel dogs were selectioned and three osseointegrated implants were placed (right hemi-mandible: one implant and in the left hemi-mandible: two implants). After two months, both prostheses were fixed on the implants and the animals were sacrificed. The hemi-mandibles were fixed in a special device (CAMPOS, 2001) and placed on the holographic table. A static load was applied on three different positions on the prosthesis (anterior abutment, midpoint of the bar and posterior abutment) and eighteen holograms were obtained. The hologram analysis revealed that the hemi-mandibles with tooth-implant prosthesis transmitted more tension that the hemi-mandibles with implant supported prosthesis. In addition to, an equal distribution of stress were observed in the implant supported prosthesis when compared with the tooth-implant prosthesis.
302

Análise da força de retenção de cimentos resinosos em modelo representativo da técnica de cimentação passiva para implantes osseointegráveis / Analysis of resin cement retention strength in a representative model of passive cementation technique for osseointegration implants

Hilmo Barreto Leite Falcão Filho 29 June 2009 (has links)
O objetivo deste estudo foi analisar a força de retenção de dois cimentos resinosos utilizados na técnica de cimentação passiva para implantes osseointegráveis, Panavia F e RelyX U100, avaliando essa propriedade na sua aplicação em espécimes de três tipos de diferentes metais, NiCr (Verabond 2, Aalba Dental), NiCrTi (Tilite Ômega, Talladium) e Titânio (Ti c.p., grau 2, Realum), submetidos ou não à termociclagem. Noventa e seis cilindros calcináveis (Conexão Sistemas de Próteses) foram encerados de forma padronizada, fundidos (32 cilindros em cada tipo de liga) e cimentados sobre cilindros de titânio (Conexão Sistemas de Próteses). Os corpos-de-prova foram distribuídos em 12 grupos (n = 8) de acordo com o tipo de liga, cimento e ciclagem térmica. Todos os espécimes foram submetidos a imersão em água destilada a 37º C por 24 horas, entretanto apenas metade deles a um ensaio de termociclagem em uma máquina de simulação de ciclos térmicos MSCT-3 por 5000 ciclos durante 30 dias. Todos os corpos-de-prova foram submetidos a ensaios de tração em uma máquina de ensaios mecânicos EMIC-DL2000 (velocidade = 5mm / min e célula de carga = 500 Kgf ). A análise estatística evidenciou resistência de união à tração do cimento RelyX U100 superior ao cimento Panavia F, independente do tipo de metal utilizado, com médias de até 71,18 Kgf e 55,08 Kgf respectivamente. O ensaio de termociclagem não exibiu interferência na resistência de união de ambos cimentos. / The aim of this study was to analyze the bond strength of two resin cements used in the passive cementation technique for osseointegrated implants, Panavia F and RelyX U100, evaluating this property on its application in specimens of three different metal types, NiCr (Verabond 2, Dental Aalba), NiCrTi (Tilite Omega, Talladium) and Titanium (Ti c.p., degree 2, Realum), submitted or not to termocycling assay. Ninety six calcined cylinders (Conexão Sistemas de Próteses) had been waxed of standardized form, casted (32 in each type of league) and cemented on titanium cylinders (Conexão Sistemas de Próteses). The specimens were distributed enter 12 groups (n = 8) in accordance with the type of metal, cement and thermocycling. All specimens were submitted to an immersion in distilled water at 37ºC for 24 hours, however only half of them to a termocycling assay in a simulation thermal cycles machine MSCT-3 for 5000 cycles during 30 days. All specimens were submitted to a tensile test in a mechanical test machine EMIC-DL2000 (speed = 5mm/min and cell load = 500Kgf). The statistics analysis evidenced tensile strength of the RelyX U100 cement greater than Panavia F cement independent of the metal league type used with averages until 71,18 Kgf and 55,08 Kgf respectively. The termocycling assay did not show interference in the tensile strength of both cements.
303

\"Estudo longitudinal da força de mordida em pacientes portadores de próteses parciais fixas sobre implantes osseointegrados: comparação entre áreas dentadas e implantadas\" / Bite force longitudinal study on patients wearing implant-supported partial prothesis

Fileni, Renan Hollanda 22 March 2007 (has links)
A proposta deste estudo foi analisar o desenvolvimento da força máxima de mordida em um grupo de pacientes que recebeu próteses parciais fixas sobre implantes (PPFSI) nas regiões de molares, pré-molares até caninos e incisivos antagonizando com dentes naturais e comparar os resultados obtidos com as áreas dentadas do mesmo grupo de pacientes, durante um período de 64 meses (5,3 anos). As forças de mordida foram medidas em cinco regiões da boca: molares em ambos os lados, pré-molares ou caninos em ambos os lados e incisivos; nas áreas de próteses sobre implantes e também nas áreas de dentes naturais. Para tanto, foi usado um transdutor medidor de força de mordida, que tem como princípio de funcionamento uma célula de força colada a um garfo de mordida, amplamente usado na literatura e sempre operado pelo pesquisador. As medições foram feitas imediatamente após a instalação das próteses, 3, 30 e 64 meses depois. Comparando o desenvolvimento das forças de mordida entre as áreas implantadas e de dentes naturais encontra-se já no primeiro controle, após 3 meses de instalação, um aumento das forças de mordida nas próteses sobre implantes instaladas na região de molares que supera as forças desenvolvidas por dentes naturais na mesma região. Para as próteses instaladas na área de incisivos, ao contrário, não foi registrado aumento estatístico destas forças, havendo uma tendência em permanecerem menores quando comparadas às forças desenvolvidas nas mesmas regiões por dentes naturais. Na região de pré-molares ou caninos não houve aumento estatístico de força nas PPFSI. Quando analisadas as áreas dentadas dos pacientes, não houve mudança estatística de força de mordida em nenhuma das regiões durante todo o experimento. / This study proposal was to analyse the changes on the maximal bite force on a patients sample who had implant-supported partial fixed prosthesis (FPP) installed and the results were compared to the ones obtained from the dentate areas on the same sample. Sixteen patients were followed for sixty-four months (5.3 years) and the bite forces were measured on the mouth regions which the prosthesis were installed (molars and premolars up to canines and incisors regions). This measured occurred on five regions of the mouth: both side molars, pre-molars or canines and incisives; either on the places it had a implant as well as on the natural teeth area. In order to do that, it was used as a measuring device, a largely used apparatus which consisted of a biting fork provided with a strain gauge. The bite forces recordings were made at the time of prosthesis installation, after 3, 30 and 64 months thereafter. It was found a bite force increase in the initial period of 3 months after the prosthesis installation in the area of FPP in the molar regions. In this period the bite forces became higher than in dentate situation in the same region and it manteined on this level until the final of the experiment. Comparing the bite straight development between the implanted areas and the natural teeth areas, we found a bite force increased on the prostheses installed over the molars region that overcome the straight development for natural teeth on the same area. On the other hand, for the prostheses installed on the incisive areas, we had not found a statistical straight increased. Actually, it was a tendency to keep smaller than the straight developed on the same regions by natural teeth. On premolars regions or canines, there was not a straight statistical increased on PPFSI. When we analyze the patients? teeth areas, there was not a statistical bite increase on any of the premolars or canines regions during the entire experiment.
304

Proposta de um método de projeto de próteses de membros superiores com a utilização da engenharia e análise do valor. / Proposal of an upper limb prosthesis design method, which uses the value analysis and engineering.

Carvalho, Gustavo Longhi de 18 February 2004 (has links)
As próteses de membros superiores atualmente disponíveis no mercado não atendem a muitos dos requisitos dos seus usuários, em especial devido à funcionalidade insuficiente e a seu alto peso e custo. Este fato, aliado à importância do assunto, foi a motivação deste trabalho, que utiliza a Análise do Valor no projeto deste tipo de próteses. Para isto, propõe uma metodologia de projeto, que utiliza a mencionada Análise, e aplica a mesma às próteses de membros superiores com o objetivo de obter configurações das mesmas que contenham vantagens comparando-se com as disponíveis atualmente. A Análise do Valor trabalha com funções, e por isto, as próteses, neste trabalho, foram vistas através das funções que deveriam executar. Para a obtenção destas funções e das suas especificações, foram consultados usuários de próteses, de quem as opiniões foram consideradas as mais importantes. Após estas consultas, foi executado um brainstorming com voluntários para a obtenção de idéias de novos componentes e novos tipos de próteses. A partir do resultado das entrevistas com usuários e do brainstorming, e com base nas pesquisas realizadas, foram propostas novas configurações de próteses que procurassem atender ao máximo possível das especificações que tinham sido obtidas. Em suma, esta dissertação pretende fornecer mais subsídios para se entender o que é necessário para que as próteses de membros superiores tenham uma aceitação maior e auxiliem mais seus usuários. A metodologia proposta, por sua vez, mostrou que tem potencial para ser útil na obtenção de produtos cada vez melhores, visto que ela pode ser aplicada a produtos em geral, não somente às próteses. / The available upper limb prosthesis in the market at this moment don’t correspond to many of the users’ requirements, mainly because of the insufficient functionality and the high weight and cost. This fact, allied to the importance of the subject, was the motivation of this work, which uses the Value Analysis in this kind of prosthesis design. For this purpose, it proposes a design method, which uses the mentioned Analysis, and applies it to the upper limb prosthesis aiming to obtain this product configurations with advantages, comparing to the available prosthesis at this moment. The Value Analysis works with functions, and, because of that, the prosthesis, in this work, were seen through the functions they should execute. To obtain these functions and its specifications, prosthesis users were consulted – their opinions were considered the most important. After these consultations, it was executed a brainstorming with volunteers to obtain new prosthesis’ kinds and components ideas. With the interviews and brainstorming results, and supported by the research made, they were proposed new prosthesis configurations, which had the goal to correspond to the maximum possible of the obtained specifications. In short, this dissertation intend to provide more subsidies to comprehend what is necessary to the upper limb prosthesis to have a bigger acceptance and help more its users. The proposed design method, at its side, showed that has potential to be useful in the more and more better products obtaining, because it can be applied to the products in general, not only to the prosthesis.
305

Avaliação da percepção estética de prótese óculo-palpebral confeccionada pelo método convencional e pelo sistema CAD/CAM / Evaluation of the aesthetic perception on oculopalpebral prosthesis obtained by the conventional method and by the CAD/CAM system

Kawabata, Simone Cristina 13 July 2016 (has links)
O uso do Sistema CAD/CAM já é bastante consagrado na Odontologia, não sendo diferente na reabilitação facial. Traz diversas facilidades, porém poucos trabalhos relatam as reabilitações da região óculo-palpebral. Nesse estudo, a aquisição de imagem tridimensional foi feita com o uso de um escâner de superfície a laser, FARO Edge ScanArm®, protegendo-se o olho contralateral com uso de lente gelatinosa preta; método que demonstrou eficiência na obtenção de imagem de pálpebras abertas para confecção de protótipo reverso. Foram selecionados 10 pacientes com exenteração de órbita, de ambos os gêneros, sendo 5 com mutilação à esquerda e 5 à direita. Todos os pacientes receberam duas próteses óculo-palpebrais, uma confeccionada pelo método convencional e outra pelo sistema CAD/CAM. As reabilitações foram registradas fotograficamente e avaliadas por 30 indivíduos leigos, 3 especialistas em prótese bucomaxilofacial e pelos próprios pacientes, usando-se a Escala VAS. Para avaliar a variação intraexaminador, 15 leigos repetiram a avaliação com intervalo de uma semana, assim como os 3 especialistas. Os resultados demonstraram consistência interna e uma boa reprodutibilidade dos dados em todos os grupos. A percepção estética foi melhor avaliada nas próteses obtidas pelo método convencional; entretanto, a relevância da diferença observada entre os dois métodos foi avaliada como razoável. / The use of CAD/CAM system is already an established method in Dentistry, no different in facial rehabilitation. It brings several facilities, but few studies have already reported the rehabilitations of the orbital area. In this research the acquisition of the three dimensional image was taken using a surface laser scanner, FARO Edge ScanArm®, protecting the contralateral eye with the use of a black gelatinous contact lens; this method has demonstrated effectiveness in getting image with open eyelids for making reverse prototype. 10 patients were select with orbit exenteration, of both genders, 5 with left mutilation and 5 with right. All patients received two oculopalpebral prostheses, one obtained by the conventional method and another by the CAD/CAM system. The rehabilitations were photo registrated and assessed by 30 lay assessors, 3 bucomaxillofacial prosthetic specialists and by the patients themselves using the VAS Scale. To evaluate the intraexaminer variation, 15 lay assessors repeated the evaluation with one week interval, as did the specialists. The results demonstrated good interexaminer variation and reproducibility of data in all groups. The aesthetic perception was better evaluated in prostheses obtained by the conventional method; however, the relevance of difference between the two methods was assessed as a reasonable one.
306

Heterotopic Ossification : Clinical and Experimental Studies on Risk Factors, Etiology and Inhibition by Non-steroidal Anti-inflammatory Drugs

Persson, Per-Erik January 2004 (has links)
<p>In this thesis, occurrence of heterotopic ossification (HO) following total hip arthroplasty (THA) was studied. Preventive effects and complications with non-steroidal anti-inflammatory drugs (NSAIDs) were analyzed. Experimental investigations on bone formation were employed to gain insight to the mechanism of NSAIDs action on bone.</p><p>(I). Fifty-six patients with bilateral THAs were analyzed. We found a strong correlation between HO on the two sides. Incidence and grade of HO were higher in men than in women.</p><p>(II). Sixty-nine patients with bilateral THAs who had been treated with NSAIDs after one or both THAs were analyzed for HO. Widespread HO occurred in untreated THAs, but in none of the treated THAs.</p><p>(III). A consecutive series of THAs were analyzed for HO. No widespread HO occurred in patients treated with NSAIDs for 21 days. In contrast, widespread HO occurred in 23% of patients not treated.</p><p>(IV). A randomized, double-blind, prospective study on 144 patients was performed to determine the efficacy and minimum treatment time with Ibuprofen for prophylaxis of HO after THA. Treatment with Ibuprofen was effective for preventing HO and a treatment time of 8 days was sufficient.</p><p>(V). A ten-year follow-up examination was performed on the patients from study IV. Thirteen patients had been revised. All but one belonged to groups treated with Ibuprofen. However, the prosthetic survival time was not statistically different for patients treated with NSAIDs compared to the control group. Eighty-four more patients underwent radiographic examination10 years after THA. Nine loose prostheses were found. These were equally distributed between NSAIDs-treated and non-treated THAs. When combining complications (revisions and radiographic loosening) no significant effects could be verified.</p><p>(VI). Experimental induction of heterotopic new bone with demineralized allogeneic bone matrix (DABM) and with bone autografts, was used in rats to study effects of NSAIDs on new bone formation. Indomethacin inhibited net bone formation in DABMs and in orthotopic fractured bone. In contrast, a net mineral loss occurred in autografts, but neither mineral content nor <sup>45</sup>Ca incorporation was affected by Indomethacin treatment. The amount of bone formed per mg implanted DABM was linearly correlated to implant size.</p>
307

Heterotopic Ossification : Clinical and Experimental Studies on Risk Factors, Etiology and Inhibition by Non-steroidal Anti-inflammatory Drugs

Persson, Per-Erik January 2004 (has links)
In this thesis, occurrence of heterotopic ossification (HO) following total hip arthroplasty (THA) was studied. Preventive effects and complications with non-steroidal anti-inflammatory drugs (NSAIDs) were analyzed. Experimental investigations on bone formation were employed to gain insight to the mechanism of NSAIDs action on bone. (I). Fifty-six patients with bilateral THAs were analyzed. We found a strong correlation between HO on the two sides. Incidence and grade of HO were higher in men than in women. (II). Sixty-nine patients with bilateral THAs who had been treated with NSAIDs after one or both THAs were analyzed for HO. Widespread HO occurred in untreated THAs, but in none of the treated THAs. (III). A consecutive series of THAs were analyzed for HO. No widespread HO occurred in patients treated with NSAIDs for 21 days. In contrast, widespread HO occurred in 23% of patients not treated. (IV). A randomized, double-blind, prospective study on 144 patients was performed to determine the efficacy and minimum treatment time with Ibuprofen for prophylaxis of HO after THA. Treatment with Ibuprofen was effective for preventing HO and a treatment time of 8 days was sufficient. (V). A ten-year follow-up examination was performed on the patients from study IV. Thirteen patients had been revised. All but one belonged to groups treated with Ibuprofen. However, the prosthetic survival time was not statistically different for patients treated with NSAIDs compared to the control group. Eighty-four more patients underwent radiographic examination10 years after THA. Nine loose prostheses were found. These were equally distributed between NSAIDs-treated and non-treated THAs. When combining complications (revisions and radiographic loosening) no significant effects could be verified. (VI). Experimental induction of heterotopic new bone with demineralized allogeneic bone matrix (DABM) and with bone autografts, was used in rats to study effects of NSAIDs on new bone formation. Indomethacin inhibited net bone formation in DABMs and in orthotopic fractured bone. In contrast, a net mineral loss occurred in autografts, but neither mineral content nor 45Ca incorporation was affected by Indomethacin treatment. The amount of bone formed per mg implanted DABM was linearly correlated to implant size.
308

Efeito da desinfecção química e do envelhecimento acelerado sobre a, estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore A”, deterioração e estabilidade de cor de silicone para próteses faciais com distintas pigmentações

Pesqueira, Aldieris Alves [UNESP] 13 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-13Bitstream added on 2014-06-13T20:58:51Z : No. of bitstreams: 1 pesqueira_aa_me_araca.pdf: 540641 bytes, checksum: 5dfe2f80d73fb4a9cb52016d432619cf (MD5) / Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore A”, deterioração e estabilidade de cor, de um silicone facial, com distintas pigmentações, sob a influência da desinfecção e do envelhecimento acelerado. Para isso foram obtidos 60 corpos-de-prova, utilizando o silicone Silastic MDX 4- 4210, divididos em 3 grupos: sem pigmentação, pigmentado com pó de maquiagem e pigmentado com cerâmica. Metade dos corpos-de-prova de cada grupo foram submetidas à desinfecção com Efferdent e a outra metade com sabão neutro por 60 dias. Após esse período todos os corpos-de-prova (n=10) foram levados a uma câmara de envelhecimento acelerado para corpos não metálicos. Os ensaios de deterioração, estabilidade dimensional, reprodução e manutenção de detalhes, dureza Shore A e estabilidade de cor foram realizados após sua confecção, desinfecção e nos intervalos de cada ciclo de envelhecimento acelerado (252, 504 e 1008 horas). Os corpos-de-prova foram analisados, em computador pelo sistema AutoCAD para verificação da alteração dimensional linear e observados, em lupa estereoscópica para a análise da reprodução de detalhes. A dureza dos materiais foi analisada em durômetro Shore A e pesados em balança digital de precisão para análise da deterioração. A estabilidade de cor foi analisada por meio de espectrofotometria. Os valores encontrados dos testes de estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore a“ e estabilidade de cor foram submetidos à análise de variância e teste de Tukey em nível de 1% de probabilidade. Para a análise da reprodução e manutenção de detalhes foi utilizado escore. Pôde-se observar que os fatores desinfecção química e o envelhecimento acelerado influenciaram estatisticamente na deterioração, estabilidade dimensional, dureza... / The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details, Shore A hardness, deterioration and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated wheatering. 60 samples were obtained, using silicone Silastic MDX 4-4210, divided in 3 groups: nonpigmented, pigmented with make-up powder and pigmented with ceramics. The half of the samples of each group was submitted to the disinfection with Efferdent and another one with neutral soap per 60 days. After this period all the samples were taken to a chamber of accelerated wheatering for not metallic bodies (n=10). The tests of deterioration, dimensional stability, maintenance of the details, Shore A hardness and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated wheatering (252, 504 e 1008 horas). Samples were weighty in digital balance for analysis of deterioration. Analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. Materials hardness was analyzed in Shore A durometer and the color stability by means of spectrophotometer. The values had been submitted to the analysis of variance and Tukey test (1%). It can be observed that the factors: chemical disinfection and the accelerated wheatering had influenced statistically in deterioration, dimensional stability, Shore A hardness and color stability of the materials independently of the pigmented. With relation to the reproduction and maintenance of details, the values did not change independently of the pigmented, disinfection and accelerated wheatering.
309

Proposta de um método de projeto de próteses de membros superiores com a utilização da engenharia e análise do valor. / Proposal of an upper limb prosthesis design method, which uses the value analysis and engineering.

Gustavo Longhi de Carvalho 18 February 2004 (has links)
As próteses de membros superiores atualmente disponíveis no mercado não atendem a muitos dos requisitos dos seus usuários, em especial devido à funcionalidade insuficiente e a seu alto peso e custo. Este fato, aliado à importância do assunto, foi a motivação deste trabalho, que utiliza a Análise do Valor no projeto deste tipo de próteses. Para isto, propõe uma metodologia de projeto, que utiliza a mencionada Análise, e aplica a mesma às próteses de membros superiores com o objetivo de obter configurações das mesmas que contenham vantagens comparando-se com as disponíveis atualmente. A Análise do Valor trabalha com funções, e por isto, as próteses, neste trabalho, foram vistas através das funções que deveriam executar. Para a obtenção destas funções e das suas especificações, foram consultados usuários de próteses, de quem as opiniões foram consideradas as mais importantes. Após estas consultas, foi executado um brainstorming com voluntários para a obtenção de idéias de novos componentes e novos tipos de próteses. A partir do resultado das entrevistas com usuários e do brainstorming, e com base nas pesquisas realizadas, foram propostas novas configurações de próteses que procurassem atender ao máximo possível das especificações que tinham sido obtidas. Em suma, esta dissertação pretende fornecer mais subsídios para se entender o que é necessário para que as próteses de membros superiores tenham uma aceitação maior e auxiliem mais seus usuários. A metodologia proposta, por sua vez, mostrou que tem potencial para ser útil na obtenção de produtos cada vez melhores, visto que ela pode ser aplicada a produtos em geral, não somente às próteses. / The available upper limb prosthesis in the market at this moment don’t correspond to many of the users’ requirements, mainly because of the insufficient functionality and the high weight and cost. This fact, allied to the importance of the subject, was the motivation of this work, which uses the Value Analysis in this kind of prosthesis design. For this purpose, it proposes a design method, which uses the mentioned Analysis, and applies it to the upper limb prosthesis aiming to obtain this product configurations with advantages, comparing to the available prosthesis at this moment. The Value Analysis works with functions, and, because of that, the prosthesis, in this work, were seen through the functions they should execute. To obtain these functions and its specifications, prosthesis users were consulted – their opinions were considered the most important. After these consultations, it was executed a brainstorming with volunteers to obtain new prosthesis’ kinds and components ideas. With the interviews and brainstorming results, and supported by the research made, they were proposed new prosthesis configurations, which had the goal to correspond to the maximum possible of the obtained specifications. In short, this dissertation intend to provide more subsidies to comprehend what is necessary to the upper limb prosthesis to have a bigger acceptance and help more its users. The proposed design method, at its side, showed that has potential to be useful in the more and more better products obtaining, because it can be applied to the products in general, not only to the prosthesis.
310

Avaliação da percepção estética de prótese óculo-palpebral confeccionada pelo método convencional e pelo sistema CAD/CAM / Evaluation of the aesthetic perception on oculopalpebral prosthesis obtained by the conventional method and by the CAD/CAM system

Simone Cristina Kawabata 13 July 2016 (has links)
O uso do Sistema CAD/CAM já é bastante consagrado na Odontologia, não sendo diferente na reabilitação facial. Traz diversas facilidades, porém poucos trabalhos relatam as reabilitações da região óculo-palpebral. Nesse estudo, a aquisição de imagem tridimensional foi feita com o uso de um escâner de superfície a laser, FARO Edge ScanArm®, protegendo-se o olho contralateral com uso de lente gelatinosa preta; método que demonstrou eficiência na obtenção de imagem de pálpebras abertas para confecção de protótipo reverso. Foram selecionados 10 pacientes com exenteração de órbita, de ambos os gêneros, sendo 5 com mutilação à esquerda e 5 à direita. Todos os pacientes receberam duas próteses óculo-palpebrais, uma confeccionada pelo método convencional e outra pelo sistema CAD/CAM. As reabilitações foram registradas fotograficamente e avaliadas por 30 indivíduos leigos, 3 especialistas em prótese bucomaxilofacial e pelos próprios pacientes, usando-se a Escala VAS. Para avaliar a variação intraexaminador, 15 leigos repetiram a avaliação com intervalo de uma semana, assim como os 3 especialistas. Os resultados demonstraram consistência interna e uma boa reprodutibilidade dos dados em todos os grupos. A percepção estética foi melhor avaliada nas próteses obtidas pelo método convencional; entretanto, a relevância da diferença observada entre os dois métodos foi avaliada como razoável. / The use of CAD/CAM system is already an established method in Dentistry, no different in facial rehabilitation. It brings several facilities, but few studies have already reported the rehabilitations of the orbital area. In this research the acquisition of the three dimensional image was taken using a surface laser scanner, FARO Edge ScanArm®, protecting the contralateral eye with the use of a black gelatinous contact lens; this method has demonstrated effectiveness in getting image with open eyelids for making reverse prototype. 10 patients were select with orbit exenteration, of both genders, 5 with left mutilation and 5 with right. All patients received two oculopalpebral prostheses, one obtained by the conventional method and another by the CAD/CAM system. The rehabilitations were photo registrated and assessed by 30 lay assessors, 3 bucomaxillofacial prosthetic specialists and by the patients themselves using the VAS Scale. To evaluate the intraexaminer variation, 15 lay assessors repeated the evaluation with one week interval, as did the specialists. The results demonstrated good interexaminer variation and reproducibility of data in all groups. The aesthetic perception was better evaluated in prostheses obtained by the conventional method; however, the relevance of difference between the two methods was assessed as a reasonable one.

Page generated in 0.0576 seconds