• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1028
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 88
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Efeito da ciclagem mecânica, material e retorque de parafusos, na estabilidade de próteses múltiplas sobre implantes com dois níveis de desajuste / Effect of mechanical cycling, material and retorque screws, in stability of complete implant-suported prosthesis with two fit levels

Farina, Ana Paula 03 January 2011 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T03:20:12Z (GMT). No. of bitstreams: 1 Farina_AnaPaula_D.pdf: 1605705 bytes, checksum: 829e909eecce5995165949e1b708c7d8 (MD5) Previous issue date: 2011 / Resumo: O afrouxamento dos parafusos protéticos é frequentemente encontrado nos exames de rotina e pode causar complicações. Assim, métodos para sua prevenção devem ser desenvolvidos. O objetivo neste estudo foi avaliar a influência do retorque de parafusos protéticos (titânio ou ouro) na estabilidade de próteses totais implantossuportadas com diferentes níveis de adaptação (passiva ou desadaptada), após simulação da função mastigatória por meio de ciclagem mecânica (6 meses, torque de afrouxamento, reaperto dos parafusos + 6 meses de simulação; ou 1 ano de simulação e torque de afrouxamento). No capítulo 1, 10 próteses mandibulares implantossuportadas e 20 modelos foram confeccionados para duas condições de adaptação: passiva (adaptada) e não-passiva (desadaptada). Também foram avaliadas duas técnicas de aperto em função da aplicação de retorque e materiais do parafuso: 1) sem retorque + parafusos de titânio; 2) sem retorque + parafusos de ouro; 3) com retorque + parafusos de titânio; e, 4) com retorque + parafusos de ouro. Para a técnica de aplicação de retorque, os parafusos foram apertados (10 Ncm) e após 10 minutos, reapertados (10 Ncm). O torque de afrouxamento dos parafusos foi mensurado por meio de torquímetro digital de precisão após simulação de 1 ano da função mastigatória. Os dados foram submetidos à análise de variância (ANOVA) em 2 fatores seguido pelo teste complementar de Tukey em (?=0,05). Os fatores adaptação e técnica de aperto (retorque e tipo de parafuso), e a interação entre os fatores foram estatisticamente significantes. O desajuste diminui o torque de afrouxamento. A aplicação do retorque aumentou a estabilidade da conexão dos parafusos, independente da adaptação ou material dos parafusos. No capítulo 2, próteses passivas e não-passivas foram fabricadas de modo semelhante ao capítulo 1. O torque de afrouxamento foi mensurado após 2 condições de simulação de uso clínico: 1) 6 meses / torque de afrouxamento / reaperto / mais 6 meses / torque de afrouxamento; 2) 1 ano de simulação / torque de afrouxamento. Foram utilizados parafusos de titânio e ouro. O teste estatístico foi similar ao capítulo 1. O fator tempo de ciclagem e condição de uso (nível de ajuste e tipo de parafuso), bem como a interação desses fatores influenciaram os valores de torque de afrouxamento (p<0,05). Após 6 meses + 6 meses de simulação de uso clínico, os parafusos de titânio apresentaram maiores valores de torque de afrouxamento quando comparados aos parafusos de ouro, para o mesmo nível de adaptação. Após 1 ano de simulação de uso clínico, ambos materiais dos parafusos em próteses passivas apresentaram valores mais elevados que em próteses não-passivas. Dessa forma podemos concluir que a desadaptação reduz o torque de afrouxamento dos parafusos e que o retorque após 10 minutos consegue estabilizá-los. Parafusos de titânio apresentaram maior estabilidade que parafusos de ouro após 6 meses de simulação devido a sua menor deformação plástica. Quando o tempo de ciclagem foi analisado, parafusos de titânio apresentaram menor estabilidade após 1 ano de simulação devido à perda de torque frente à desadaptação, necessitando acompanhamento mais criterioso para que mantenham sua estabilidade / Abstract: The prosthesis screw loosening is often found at routine examinations and may cause complications. Therefore, methods to prevent them must be developed. The objective of this study was to evaluate the influence of retorque application on joint stability of prosthetic screws (titanium or gold) in implant-supported dentures under different fit levels (passive or misfit), after masticatory function simulated by means of mechanical cycling (6 months, loosening torque, screws retightening and another 6 months of simulation; or 1 year of simulation). In the first chapter, 10 mandibular implant-supported dentures and 20 cast models were fabricated to two fit levels: passive fit and misfit. Two tightening techniques were also evaluated according to the retorque application and screws material: 1) without retorque + titanium screws; 2) without retorque + gold screws; 3) retorque + titanium screws; and 4) retorque + gold screws. The screws were tightened 10 Ncm and retightened to 10 Ncm after 10 min. The screw joint stability was measured after a one-year clinical function simulation using a digital torque meter. Data were analyzed statistically by ANOVA/Tukey's test (?=0.05). The factors of fit level and tightening technique and the interaction between the factors were statistically significant. The misfit decreases the loosening torque. The retorque application increased joint stability independent of fit level or screw material. In the chapter 2, passive and misfit dentures were fabricated as in chapter 1. The loosening torque was measured after two conditions of clinical use simulating: six months / torque loosening / retightening / further six months / loosening torque; and one year of simulation / loosening torque. Titanium and gold screws were used. The statistical analysis was similar to the first chapter. Therefore, the factor cycling time and condition use (fit level and screw type) as well the interaction between the factors influenced the loosening torque values (p<0.05). After six months another six months of masticatory function simulated, the titanium screws showed higher loosening torque than did gold screws for the same fit level. After one year of clinical use simulation, both material screws in passive dentures showed higher loosening torque values than did misfit dentures. Thus we can conclude that the misfit decreases the loosening torque and retorque application increased joint stability. The stability of titanium screws was higher than gold screws after 6 months of simulation, due to its lower plastic deformation. When the cycling time was analyzed, titanium screws were less stable after 1 year of simulation due to loss of torque in misfit presence, requiring more careful monitoring to maintain stability / Doutorado / Protese Dental / Doutor em Clínica Odontológica
262

Análise tridimensional por elemento finito do comportamento biomecânico de próteses totais fixas implantossuportadas = efeito do tipo de conexão protética, cargas oclusais e número de implantes / Three-dimensional finite element analysis of biomechanics of implant-supported fixed prostheses : effect of connection system, occlusal load, and number of implants

Dayrell, Andreza Costa 18 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T05:15:14Z (GMT). No. of bitstreams: 1 Dayrell_AndrezaCosta_D.pdf: 2283239 bytes, checksum: 78a83ffa41273620963821d103b0e585 (MD5) Previous issue date: 2011 / Resumo: A proposta neste estudo foi analisar a distribuição de tensão pelo método de elementos finitos tridimensional em próteses totais fixas inferiores implantossuportadas e região óssea peri-implantar, utilizando-se dois tipos de conexão implante-abutment externa e interna, correlacionadas ao efeito de cargas axiais e número de implantes. Modelos virtuais foram elaborados simulando uma prótese total fixa implanto suportada mandibular, de acordo com o protocolo Branemark, tendo como fatores de estudo as conexões implant-abutment Cone Morse (CM) e Hexágono Externo (HE); quatro e cinco implantes; cargas axiais 100 N bilateral, 300 N bilateral e unilateral. As condições de análise foram: 1. Próteses fixas com conexão interna Cone Morse (CM) submetidas à seis condições experimentais constituindo os modelos M1, M2 e M3 com quatro implantes e cargas de 100 N e 300 N, respectivamente; os modelos M4, M5, e M6 com cinco implantes e cargas similares; 2. Próteses fixas com conexão externa Hex Externo (HE), submetidas às mesmas condições; 3. Comparação entre os dois sistemas de conexão. Os resultados de deformação óssea (??), sob efeito de cargas axiais de 100 N, distribuíram-se homogeneamente nos grupos com CM e concentraram-se nos implantes distais nos grupos com HE. Sob efeito de cargas axiais de 300 N, a distribuição de tensão acompanhou a mesma tendência anterior, com aumento de deformação no osso (??) e implantes (MPa) cerca de 1,5-2 vezes para os grupos com CM e 3 vezes para os grupos com HE. Dentro das condições do estudo concluiu-se que: 1. sob efeito de cargas axiais de 100 N o uso das duas conexões implante-abutment Cone Morse e Hexágono Externo é bem indicado; 2. sob efeito de cargas axiais de 300 N a conexão Cone Morse apresenta melhor indicação; 3. cinco implantes não representam benefício relevante em relação à quatro; 4. com o sistema de conexão Cone Morse, a solicitação mecânica distribui-se por todos os implantes e região óssea, com o sistema Hexágono Externo, concentra-se nos distais e região óssea circundante; 5. a distribuição de tensão na infraestrutura protética é similar com os dois sistemas de conexão, apresentando resistência mecânica satisfatória com a conexão Hexágono Externo e cargas axiais de 100 N e insuficiente para ambas as conexões sob cargas axiais de 300 N / Abstract: The purpose of this study was to analyze the stress and strain distribution by three-dimensional finite element method in implant supported fixed prostheses and peri-implantar bone region, using two types of implant-abutment connection internal and external, correlated to the effect of axial loadings and number of implants. Virtual models were developed by simulating a mandibular implant supported fixed prostheses, according to the Branemark protocol, with study factors: implant-abutment connection Morse taper (MT) and External hexagon (EH); four or five implants; bilateral axial loadings 100 N, bilateral and unilateral axial loadings 300 N. The analysis conditions were: 1. Fixed prostheses with internal connection Morse taper interface (MT) simulating six experimental conditions, making the models M1, M2 and M3 with four implants and loads of 100 N and 300 N, respectively; models M4, M5, M6 with five implants and similar conditions; 2. Fixed prostheses with external connection External hexagon interface (EH), submitted to same conditions; 3. Comparison between the two connection systems. The results of von Mises stress and bone strain, under effect of 100 N axial loadings, were distributed evenly for all implants for groups with MT, focused mainly on the distal implants for groups with EH. Under effect of 300 N axial loadings, the stress and strain distribution followed the same tendency, with values increased of 1.5-2 times for the MT group and 3 times for EH groups. Within the analysis conditions the study concluded that: 1. under effect of axial loadings of 100 N, the use of two implant-abutment connections MT and EH can be well indicated; 2. under effect of axial loadings of 300 N, the Morse taper connection provides a better indication; 3. Five implants do not represent relevant benefit over four; 4. with Morse taper connection system, the mechanical stress is distributed for all implants and bone area, with the External hexagon, focuses on the distal region and surrounding bone; 5. the stress distribution in prosthetic infrastructure is similar with the two connection systems and the mechanical strength is satisfactory for groups with prosthetic connection EH and 100 N axial loadings, and insufficient for both prosthetic connections under effect of 300 N axial loadings / Doutorado / Protese Dental / Doutor em Clínica Odontológica
263

Prevalencia de sinais e sintomas de desordens temporomandibulares em adultos : estudo retrospectivo de pacientes tratados pelo CETASE / Prevalence of signs and symptoms of temporomandibular disorders (TMD) in adults : a retrospective study of patients treated in the CETASE

Cruz, Monica Vieira de Jesus 17 August 2006 (has links)
Orientador: Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T08:54:26Z (GMT). No. of bitstreams: 1 Cruz_MonicaVieiradeJesus_M.pdf: 3981651 bytes, checksum: d422ba303a3055829bdb79090001a499 (MD5) Previous issue date: 2006 / Resumo: As Desordens Temporomandibulares (DTM) constituem uma parcela importante das causas de dor em odontologia, sua etiologia e tratamento são de interesse clínico, assim os estudos de prevalência dos sinais e sintomas são de fato necessários para orientar o diagnóstico e o tratamento desta doença. A proposta deste estudo foi verificar a prevalência de sinais e sintomas de DTM em pacientes tratados no CETASE ¿ Centro de Estudo e Tratamento das Alterações Funcionais do Sistema Estomatognático da FOP-UNICAMP, e a relação de predição de dores musculares e/ou articulares a partir dos sinais ou sintomas de maior prevalência na amostra estudada e contribuir para atualização da ficha clínica do CETASE, de forma a oferecer pesquisas com metodologias padronizadas, que possam ser comparadas com aquelas realizadas em diferentes centros de pesquisa internacionais. Foram avaliadas 1322 fichas clínicas de pacientes que procuraram voluntariamente o CETASE, na Faculdade de Odontologia de Piracicaba ¿ UNICAMP, para tratamento, no período de 1995 a 2004. Dentre elas foram selecionadas 400 fichas de pacientes com idades entre 18 e 80 anos, que tiveram diagnóstico de desordens temporomandibulares e foram tratados pelo CETASE. Foram coletados, em suas fichas clínicas, dados referentes a seguinte sintomatologia: ruídos articulares, travamento nos movimentos da mandíbula, dificuldade na abertura da boca, sensação de surdez, zumbido nos ouvidos, vertigem, cansaço muscular, dores articulares e dores musculares. Os dados foram analisados com auxílio do software Microsoft Office Excel 2003 for Windows XP@ (Microsoft Corporation©, EUA) e apresentados sob a forma de tabelas, para permitir uma análise percentual e descritiva. Na análise estatística foram usados os testes Exato de Fisher e Regressão Logística Múltipla, com valor de P< 0,05. Os resultados obtidos revelaram que: dentre os sinais e sintomas relatados os mais prevalentes foram ruídos e dores articulares, dores nos músculos da mastigação e da face e sensação de surdez. A presença de ruídos articulares, salto condilar e ausência de oclusão posterior, simultaneamente, pode predizer a ocorrência de dores articulares e/ou musculares. A ficha clínica do CETASE mostrou ser um instrumento confiável de coleta de dados, podendo, porém, ser adaptada ao modelo internacional do Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD), com objetivo de aumentar o poder de comparação entre os estudos realizados em diferentes centros de pesquisa no mundo / Abstract: Temporomandibular disorder (TMD) is an important cause of pain in dentistry. Studies aiming at its etiology, treatment, and prevalence are needed for a more accurate diagnosis of this disease. The aim of this study was (a) to evaluate/analyze the prevalence of signs and symptoms of TMD in volunteers treated at the Center of Studies and Treatment for Alterations in the Stomatognathic System (CETASE) at Piracicaba Dental School, University of Campinas ¿ UNICAMP, (b) to verify whether these signs and symptoms can serve as predictors of muscle and/or joint pains, and (c) to modify, or update, the clinical database form used at CETASE. This study evaluated 1.322 clinical forms of patients who looked for dental treatment at CETASE between 1995 and 2004. Among these forms, 400 were selected from volunteers aged 18¿80 years. Data collection involved information on joint noises, limitation of mandibular movements, difficulty with mouth opening, deafness sensation, vertigo, and muscle and joint pains. Fisher¿s Exact Test and Multiple Logistic Regression (p<0.05) were used for statistical analysis. Results showed that joint noises, muscle and joint pains, and deafness sensation were the most prevalent signs and symptoms. Joint noises, condylar displacement and absence of posterior occlusion can result in joint and/or muscle pains. The clinical database form used at CETASE was considered a reliable tool for data assessment; however, adaptations are needed to meet the requirements of the international model ¿ the Research Diagnostic Criteria for Temporomandibular Disorders / Mestrado / Protese Dental / Mestre em Clínica Odontológica
264

Torque de afrouxamento dos parafusos proteticos em proteses implanto-suportadas com diferentes niveis de desajuste / Loosening torque of prosthetic screws in implante-supported dentures with different fit levels

Spazzin, Aloísio Oro, 1984- 02 December 2009 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Campinas / Made available in DSpace on 2018-08-12T19:41:12Z (GMT). No. of bitstreams: 1 Spazzin_AloisioOro_M.pdf: 136206020 bytes, checksum: 3bd1b222bdf09c7c84975da4fc525ca7 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi verificar a influência da composição da liga (titânio ou ouro) e do re-aperto no torque de afrouxamento dos parafusos protéticos, sob diferentes níveis de desajustes (adaptação passiva e desajuste) de próteses mandibulares implantosuportadas. Foram confeccionadas 10 próteses totais mandibulares implanto-suportadas e criados dois níveis de desajustes, confeccionando 20 modelos de gesso (n = 10): próteses com adaptação passiva (G1_controle); e próteses com desajuste (G2). Para G1, as estruturas protéticas foram parafusadas diretamente aos análogos de mini-pilares cônicos. Para G2, os desajustes foram simulados utilizando anéis interpostos entre os cilindros da infra-estrutura e os análogos. O objetivo da interposição dos anéis foi obter média de 250 µm de desajuste no teste do parafuso único. Os análogos de todos os conjuntos montados foram incluídos em gesso utilizando delineador. Um microscópio óptico comparador (120x) foi usado para quantificar os valores de desajuste vertical no teste do parafuso único. As estruturas protéticas foram utilizadas para os dois níveis de desajustes. O torque de afrouxamento (TA) foi avaliado utilizando parafusos fabricados em liga de titânio (Ti) ou ouro (Au), sendo avaliadas também duas técnicas de aplicação de torque (10 Ncm): 1) torque e destorque após 24 horas (SR); e 2) torque, retorque após 10 minutos e destorque após 24 horas (CR). Foi utilizado torquímetro digital (TQ8800; Lutron) para aplicação do torque e leitura do TA. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) seguida do teste de Tukey (a=0,05). Os valores médios de TA (Ncm) para parafusos de Ti foram: G1/SR=6,99(±1,03); G1/CR=7,33(±0,79); G2/SR=5,65(±1,18); G2/CR=7,24(±1,00). Para parafusos de Au foram: G1/SR=5,42(±0,99);G1/CR=5,97(±1,00); G2/SR=5,03(±1,33); G2/CR=5,71(±1,02). No Capítulo-1, os materiais dos parafusos foram comparados sem aplicação do retorque (SR): Ti apresentou valor médio de TA mais elevado, diferindo estatisticamente do de Au no G1; o G2 apresentou menor valor médio de TA, diferindo estatisticamente do G1 para Ti. Não foi encontrada diferença estatística significante entre Ti e Au no G2, ou entre G1 e G2 para Au. No Capítulo-2, o retorque foi avaliado separadamente para Ti e Au. Para parafusos de Ti: o G2/SR apresentou menor valor médio de TA, diferindo estatisticamente do G1/SR; o G2/CR apresentou valor médio de TA mais elevado, diferindo estatisticamente de G2/SR; não foi encontrada diferença no valor médio de TA entre G1/CR e G2/CR, ou entre G1/SR e G1/CR. Para parafusos de Au, os grupos não apresentaram valores médios com diferença estatística entre si. Os materiais dos parafusos protéticos apresentaram comportamento diferente frente aos desajustes e retorque. A estabilidade da conexão dos parafusos de ouro não foi influenciada pelas variáveis avaliadas, enquanto os parafusos de titânio foram mais suscetíveis ao afrouxamento com aumento do desajuste, uma vez que o torque de afrouxamento diminuiu para valores semelhantes aos encontrados para os parafusos de ouro independentemente do nível de desajuste das próteses. Porém, a aplicação do retorque aumentou o torque necessário para afrouxar os parafusos de titânio para valores similares àqueles encontrados em próteses com adaptação passiva. / Resumo: O objetivo neste estudo foi verificar a influência da composição da liga (titânio ou ouro) e do re-aperto no torque de afrouxamento dos parafusos protéticos, sob diferentes níveis de desajustes (adaptação passiva e desajuste) de próteses mandibulares implantosuportadas. Foram confeccionadas 10 próteses totais mandibulares implanto-suportadas e criados dois níveis de desajustes, confeccionando 20 modelos de gesso (n = 10): próteses com adaptação passiva (G1_controle); e próteses com desajuste (G2). Para G1, as estruturas protéticas foram parafusadas diretamente aos análogos de mini-pilares cônicos. Para G2, os desajustes foram simulados utilizando anéis interpostos entre os cilindros da infra-estrutura e os análogos. O objetivo da interposição dos anéis foi obter média de 250 µm de desajuste no teste do parafuso único. Os análogos de todos os conjuntos montados foram incluídos em gesso utilizando delineador. Um microscópio óptico comparador (120x) foi usado para quantificar os valores de desajuste vertical no teste do parafuso único. As estruturas protéticas foram utilizadas para os dois níveis de desajustes. O torque de afrouxamento (TA) foi avaliado utilizando parafusos fabricados em liga de titânio (Ti) ou ouro (Au), sendo avaliadas também duas técnicas de aplicação de torque (10 Ncm): 1) torque e destorque após 24 horas (SR); e 2) torque, retorque após 10 minutos e destorque após 24 horas (CR). Foi utilizado torquímetro digital (TQ8800; Lutron) para aplicação do torque e leitura do TA. Os resultados foram submetidos à análise de variância de dois fatores (ANOVA) seguida do teste de Tukey (a=0,05). Os valores médios de TA (Ncm) para parafusos de Ti foram: G1/SR=6,99(±1,03); G1/CR=7,33(±0,79); G2/SR=5,65(±1,18); G2/CR=7,24(±1,00). Para parafusos de Au foram: G1/SR=5,42(±0,99);G1/CR=5,97(±1,00); G2/SR=5,03(±1,33); G2/CR=5,71(±1,02). No Capítulo-1, os materiais dos parafusos foram comparados sem aplicação do retorque (SR): Ti apresentou valor médio de TA mais elevado, diferindo estatisticamente do de Au no G1; o G2 apresentou menor valor médio de TA, diferindo estatisticamente do G1 para Ti. Não foi encontrada diferença estatística significante entre Ti e Au no G2, ou entre G1 e G2 para Au. No Capítulo-2, o retorque foi avaliado separadamente para Ti e Au. Para parafusos de Ti: o G2/SR apresentou menor valor médio de TA, diferindo estatisticamente do G1/SR; o G2/CR apresentou valor médio de TA mais elevado, diferindo estatisticamente de G2/SR; não foi encontrada diferença no valor médio de TA entre G1/CR e G2/CR, ou entre G1/SR e G1/CR. Para parafusos de Au, os grupos não apresentaram valores médios com diferença estatística entre si. Os materiais dos parafusos protéticos apresentaram comportamento diferente frente aos desajustes e retorque. A estabilidade da conexão dos parafusos de ouro não foi influenciada pelas variáveis avaliadas, enquanto os parafusos de titânio foram mais suscetíveis ao afrouxamento com aumento do desajuste, uma vez que o torque de afrouxamento diminuiu para valores semelhantes aos encontrados para os parafusos de ouro independentemente do nível de desajuste das próteses. Porém, a aplicação do retorque aumentou o torque necessário para afrouxar os parafusos de titânio para valores similares àqueles encontrados em próteses com adaptação passiva. / Abstract: The aim of this study was to verify the influence of alloy composition (titanium or gold) and retightening of the prosthetic screws on the loosening torque of these screws under different misfit levels (passive fit and misfit) of mandibular implant-supported prostheses. Ten mandibular implant-supported prostheses were fabricated. Two misfit levels of the prostheses were obtained fabricating twenty cast models using the prosthetic structures (n=10): prostheses with passive fit (G1_control); and prostheses with misfit (G2). For G1, the prosthetic structures were screwed directly to the analogs. For G2, the misfits were simulated using rings placed between the framework cylinders and the analogs. The analogs of all assembled sets were casted using delineator. The goal of the rings was to obtain mean of 250-µm misfit at one-screw test. An optic microscopic (120x) were used to quantifier the vertical misfit values at the one-screw test. The prosthetic frameworks were used in two misfit levels. The loosening torque (LT) was evaluated using screws made of titanium (Ti) or gold (Au) alloy, two techniques of torque application (10 Ncm) were also evaluated: 1) torque and loosening torque after 24 hours (wR); and 2) torque, retorque after 10 minutes and torque loosening after 24 hours (R). A digital torque meter (TQ8800; Lutron) was used to torque application and to measure the LT. Data were separately analyzed by two-away ANOVA followed by Tukey's test (a=0,05). The LT mean values (Ncm) for titanium screws were: G1/wR=6.99 (±1.03); G1/R=7.33(±0.79); G2/wR=5.65(±1.18); and G2/R=7.24(±1.00). For gold screws were: G1/wR=5.42(±0.99); G1/R=5.97(±1.00); G2/wR=5.03(±1.33); and G2/R=5.71(±1.02). In the Chapter-1, the screw materials were compared without retorque application (wR): Ti showed significant higher LT than Au in the G1; and G2 presented significant lower LT than G1 for Ti. No significant statistic difference was found between Ti and Au in the G2, or between G1 and G2 for Au screws. In the Chapter-2, the retorque was evaluated separately to Ti and Au. For titanium screws: the G2/wR showed lower LT than G1/wR; the G2/R presented higher LT than G2/wR; no significant difference on the LT between G1/R and G2/R; or between G1/wR and G1/R. For gold screws, the groups did not show mean values with statistic difference between each other. The prosthetic screw materials presented different behavior for the misfits and the retorque. The joint stability of the gold screw was not influenced by variables tested. While the titanium screws were more susceptible to the loosening with the misfit increase, once the loosening torque decreased to similar values those found for the gold screws regardless of the prosthetic fit level. However, the torque application increased the loosening torque of the titanium screws to similar values those found to the prostheses with passive fit. / Abstract: The aim of this study was to verify the influence of alloy composition (titanium or gold) and retightening of the prosthetic screws on the loosening torque of these screws under different misfit levels (passive fit and misfit) of mandibular implant-supported prostheses. Ten mandibular implant-supported prostheses were fabricated. Two misfit levels of the prostheses were obtained fabricating twenty cast models using the prosthetic structures (n=10): prostheses with passive fit (G1_control); and prostheses with misfit (G2). For G1, the prosthetic structures were screwed directly to the analogs. For G2, the misfits were simulated using rings placed between the framework cylinders and the analogs. The analogs of all assembled sets were casted using delineator. The goal of the rings was to obtain mean of 250-µm misfit at one-screw test. An optic microscopic (120x) were used to quantifier the vertical misfit values at the one-screw test. The prosthetic frameworks were used in two misfit levels. The loosening torque (LT) was evaluated using screws made of titanium (Ti) or gold (Au) alloy, two techniques of torque application (10 Ncm) were also evaluated: 1) torque and loosening torque after 24 hours (wR); and 2) torque, retorque after 10 minutes and torque loosening after 24 hours (R). A digital torque meter (TQ8800; Lutron) was used to torque application and to measure the LT. Data were separately analyzed by two-away ANOVA followed by Tukey's test (a=0,05). The LT mean values (Ncm) for titanium screws were: G1/wR=6.99 (±1.03); G1/R=7.33(±0.79); G2/wR=5.65(±1.18); and G2/R=7.24(±1.00). For gold screws were: G1/wR=5.42(±0.99); G1/R=5.97(±1.00); G2/wR=5.03(±1.33); and G2/R=5.71(±1.02). In the Chapter-1, the screw materials were compared without retorque application (wR): Ti showed significant higher LT than Au in the G1; and G2 presented significant lower LT than G1 for Ti. No significant statistic difference was found between Ti and Au in the G2, or between G1 and G2 for Au screws. In the Chapter-2, the retorque was evaluated separately to Ti and Au. For titanium screws: the G2/wR showed lower LT than G1/wR; the G2/R presented higher LT than G2/wR; no significant difference on the LT between G1/R and G2/R; or between G1/wR and G1/R. For gold screws, the groups did not show mean values with statistic difference between each other. The prosthetic screw materials presented different behavior for the misfits and the retorque. The joint stability of the gold screw was not influenced by variables tested. While the titanium screws were more susceptible to the loosening with the misfit increase, once the loosening torque decreased to similar values those found for the gold screws regardless of the prosthetic fit level. However, the torque application increased the loosening torque of the titanium screws to similar values those found to the prostheses with passive fit. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
265

Analise fotoelastica da distribuição de tensão em diferentes sistemas de overdentures sobre implantes osseointegrados / Photoelastic analysis of the distribution of stress in different systerms of overdentures on osseous-integrated implants

Machado, Ana Carolina Masarolo 13 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T03:34:41Z (GMT). No. of bitstreams: 1 Machado_AnaCarolinaMasarolo_M.pdf: 6585345 bytes, checksum: 5509254e08a517d153fa1da25652f8e0 (MD5) Previous issue date: 2009 / Resumo: A proposta deste estudo in vitro, foi avaliar comparativamente por meio da fotoelasticidade, os padrões de tensões geradas ao redor dos implantes e rebordo residual variando-se os sistemas de retenção em overdentures. O estudo foi baseado em três sistemas de retenção para prótese tipo overdenture, a saber: sistema o'ring com 2 implantes (GI), barra-clipe com 2 implantes (GII) e barra-clipe e o'rings distais com 4 implantes (GIII). Sobre protótipos de mandíbulas humanas desdentadas, confeccionados por meio do processo de prototipagem pelo CTI (Centro de Tecnologia da Informação, Campinas, SP) foram fixados 2 ou 4 análogos de pilares Micro-Unit (GI e GII) e análogos de implantes (GI) (Master, Conexão - São Paulo - SP) dispostos nas regiões de caninos e primeiros pré-molares inferiores. Em seguida, foram obtidos moldes dos protótipos mandibulares utilizando silicone para duplicação (Silicone Master - Talladium do Brasil), e técnica de moldagem de transferência com transferentes quadrados unidos com resina acrílica (GC Pattern - GC Dental). A partir destes moldes foram obtidas três matrizes em resina fotoelástica Araldite (Araltec Produtos Químicos Ltda., Hunstman, Guarulhos, São Paulo) com 2 ou 4 implantes osseointegrados (Master - Conexão) incorporados e/ou pilares Micro-Unit. Foram confeccionados modelos de trabalho, nos quais foram realizados os procedimentos de soldagem a laser das barras metálicas, através da moldagem de transferência do posicionamento dos implantes no protótipo mandibular. Após a adaptação de cada sistema de overdentures sobre o modelo fotoelástico, foram aplicadas cargas oclusais de 100N alternadas nas regiões posteriores e anteriores. A análise fotoelástica foi realizada com o auxílio de polariscópio plano acoplado a câmera digital Sony Cybershot a100 (Sony Corp, Japão) que permitiu visualizar as franjas e registrar as imagens em fotografias digitais. Os resultados demonstraram maior concentração de tensão no GIII, apresentando menor distribuição ao rebordo residual e sobrecarga dos implantes posteriores. O GI mostrou o menor nível de tensão, o GII intermediário nível de tensão e houve distribuição da tensão ao rebordo posterior nestes dois grupos. Palavras-chave: Implante Osseointegrado, Overdentue, Sistema Barra-clipe, Sistema O'ring, Análise Fotoelástica / Abstract: The aim of this study was to evaluate through photoelastic analysis, the distribution of generated stress around implants and adjacent bone tissue, using differents implant-retained overdentures designs. Over an edentulous human mandible, achieve from a human model, 2 or 4 micro-unit replications abutments were embedded (Master, Conexao - Sao Paulo - SP) settled in the interforaminal region. Three models of photoelastic resin (Araltec Chemicals Ltda. Hunstman, Guarulhos, Sao Paulo, Brazil), with 2 or 4 incorporated implants (Master - Conexao) and Micro-Unit abutments, were obtained from mulds using silicone for duplication (Silicone Master - talladium do Brazil). Inclusion, finishing and polishing procedures were applied on the frameworks. This study was based on three different mechanisms of implant-retained mandibular overdentures: ball attachment (GI), bar attachment (GII) (both with 2 implants) and their association (GIII) (with 4 implants). After the adaptation of each overdenture system on the photoelastics models, 100N alternates oclusals charges were applied on backside and frontside regions. The photoelastic analysis was made with the aid of a plain polariscope (Measurements Group, USA) linked to a digital camera Sony Cybershot a100 (Sony Corp, Japan) that allowed visualize the fringes and register images on digital photos. The results demonstrated higher tension concentrated over the Group III, with a flat distribution of stress to the posterior ridge and overload on the posterior implants. Group I showed the smaller stress level and Group II intermediate level, there was distribution of stress to the posterior ridge in this two groups. Key words: Osseointegrated Implant, Overdenture, Bar System, Ball System, Photoelastic Analysis / Mestrado / Protese Dental / Mestre em Clínica Odontológica
266

Estudo comparativo da adaptação marginal entre copings metalicos, In-Ceram alumina e e.max Press, antes e apos a cimentação / Comparative study of the adaptation between metallic copings, In-Cream alumina and e.max Press, before and after cementation

Silva, Ligia Luzia Buarque e 02 October 2010 (has links)
Orientador: Alexandre Brait Landulpho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:55:15Z (GMT). No. of bitstreams: 1 Silva_LigiaLuziaBuarquee_D.pdf: 1564989 bytes, checksum: 2ab1092a979d410002dd2a5d9a0cc0b8 (MD5) Previous issue date: 2010 / Resumo: Esse estudo avaliou a adaptação marginal entre copings metálicos, In-Ceram e e.max Press, antes e após cimentação em preparos sobre dentes bovinos, utilizando dois tipos de cimento resinosos. Noventa incisivos bovinos foram fixados em resina acrílica ativada quimicamente e as porções coronárias foram preparadas para coroa total, com expulsividade de 8o e término cervical em ombro. Trinta copings foram confeccionados para cada tipo de material, onde foram adaptados sobre os preparos com carga estática de 9 Kgf por 1 minuto e a discrepância marginal foi medida com microscópio de mensuração (STM). Em seguida, 15 amostras para cada tipo de coping foram cimentadas sobre os dentes com agente resinoso convencional, e mais 15 amostras para cada coping foram cimentadas com agente autoadesivo com uma carga estática de 9 Kgf por 7 minutos e novamente a discrepância marginal foi medida. Os resultados mostraram que antes da cimentação, houve diferenças significativas (p<0,05) no desajuste marginal entre os sistemas, sendo que o e.max Press apresentou maior desajuste. Após a cimentação os copings de metal e In-Ceram não apresentaram diferenças significativas (p>0,05) entre os cimentos. O sistema e.max Press apresentou um maior desajuste (p<0,05) quando cimentado com agente resinoso convencional. Quando os sistemas foram cimentados com agente resinoso convencional, o menor desajuste foi encontrado no metal (p<0,05), sendo que não houve diferenças significativas (p>0,05) entre os outros dois sistemas. Quando cimentados com o agente autoadesivo, não apresentaram diferenças significativas (p>0,05) / Abstract: This study evaluated the marginal adaptation of metal copings, In-Ceram and Press, before and after cementation in preparations on bovine teeth using two types of resin cement. Ninety bovine incisors were embedded in resin and the coronal portions of the teeth were prepared to receive complete crowns with 8o of tapering and right shoulder. Thirty crowns were fabricated for each coping. The crowns were then seated on the teeth with 9 Kgf static loads for 1 minute and the marginal discrepancy was mensured using a microscopic (STM). Afterwards, the copings were removed and fifteen samples of each coping were luted on the teeth with resin cement, and fifteen with self-adhesive resin cement applied 9 Kgf static loads for 7 minutes and the marginal discrepancy was mensured again. The results showed that before to cementation, there were significant differences (p <0.05) in the marginal fit between the systems, and the e. max Press show higher discrepancy. After cementing the metal copings and In-Ceram showed no significant differences (p>0.05) between the cements. The system e.max Press showed a significant discrepancy higher (p <0.05) when cemented with conventional resin. When the systems were cemented with resin conventional, the lowest discrepancy was found in the metal (p <0.05), with no significant differences (p> 0.05) between the other two systems. When cemented with the self agent adhesive, no significant differences (p> 0.05) / Doutorado / Protese Dental / Doutor em Clínica Odontológica
267

Avaliação de diferentes materiais utilizados no selamento da íris protética em relação à tinta acrílica utilizada em sua pintura / Evaluation of different materials used in prosthetic iris painting sealing and their relation to the acrylic paint

Shanon Leite Pereira 18 December 2007 (has links)
Na confecção de uma prótese ocular a íris artificial é a estrutura responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a interação tinta e selamento utilizados na pintura da íris protética, verificando as falhas e insucessos na fase de prensagem da íris no corpo escleral. Para este estudo, foram confeccionados quatro tipos de corpos de prova sendo, dez calotas lisas utilizando cianoacrilato como selante, dez calotas lisas utilizando polímero de acetato de vinila como selante, dez calotas despolidas utilizando cianoacrilato como selante e dez calotas despolidas utilizando polímero de acetato de vinila como selante. Os corposde- prova foram submetidos a uma análise em uma lupa estereoscópica para verificação da presença de falhas, e um corpo de prova de cada grupo foi levado a um microscópio eletrônico de varredura para estudo morfológico. Nenhum corpo de prova apresentou alteração macroscopicamente, comprovando que o protocolo utilizado é eficaz podendo-se concluir que as falhas que ocorrem na confecção de próteses oculares são decorrentes de falhas em alguma fase do protocolo. Entretanto foram observados defeitos microscópicos nos grupos selados com cola de cianoacrilato. / In the manufacturing of ocular prosthesis, the artificial iris is the structure responsible for its dissimulation and esthetic. The aim of this study was to evaluate interaction between paint and sealing material used in prosthetic iris painting, attempting to failures on packing of iris shell in sclera resin. It were studied four different groups, ten smooth shells sealed with cianoacrylate, ten smooth shells sealed with vinyl acetate polymer, ten rough shells sealed with ciaoacrylate and ten rough shells sealed with cianoacrylate. Specimens were analyzed with a stereoscopic magnifying glass for detection of failures, and one specimen of each group was analyzed in a scanning electron microscope for morphological analysis. None of the specimens presented failures macroscopically, which demonstrates that the protocol employed in the present study is effective; it can be concluded that failures in manufacturing of ocular prosthesis are consequence of mistakes in one of the steps of the protocol. However, it was detected microscopic defects in specimens of the groups sealed with cianoacrylate adhesive.
268

Estudo biomecânico do comportamento de diferentes espessuras de capa de cimento ósseo em novo modelo de prótese modular diafisária femoral em cão submetidas a ensaio de torção / Biomechanical analysis in the use of different cement layers in a new model of modular diaphyseal femoral implant relative to torsion forces

Marcos Ishimoto Della Nina 17 December 2008 (has links)
A viabilidade da utilização de próteses modulares cimentadas em diáfises de fêmur em cães foi demonstrada, porém diversos autores relatam a falha de aderência entre as próteses e os ossos como uma das principais complicações. O presente trabalho teve como objetivo investigar biomecanicamente a interface implante metálico, osso e capa de cimento ósseo de com diferentes espessuras de cimento ósseo utilizadas para a estabilização da prótese. Para tanto foram utilizados fêmures bilaterais de 24 cadáveres de cães com peso acima de 15 quilos que foram divididos em quatro grupos, o primeiro grupo composto por oito fêmures utilizou uma espessura de capa de cimento de 1,0 a 1,5 mm, o segundo grupo, composto por oito fêmures, utilizou uma capa de cimento de 2,0 a 2,5 mm e o terceiro grupo, composto por oito fêmures, utilizou uma capa de cimento compreendida entre o intervalo de 3,0 a 3,5 mm de espessura. Os fêmures foram submetidos a ensaios destrutivos de torção onde foram avaliados a rigidez à torção e torque máximo suportado pela interface implante metálico, osso e capa de cimento ósseo. O quarto grupo, denominado de controle, composto pelos fêmures contralaterais íntegros, foram submetidos ao mesmo ensaio de torção que as peças onde foram utilizadas as próteses. Os resultados encontrados foram que nas condições apresentadas neste estudo não foi encontrada diferença biomecânica estatisticamente significante, em relação à rigidez à torção e torque máximo, na utilização de capas de cimento na faixa de 1 mm e 2,5 mm e entre 2 mm e 3,5 mm. Porém houve diferença quando comparado as faixas de espessura de cimento entre os grupos de 1 mm a 1,5mm e de 3 mm a 3,5 mm. / The feasibility of modular cemented prosthesis in the femoral diaphysis was demonstrated in dogs, but several authors report loosening of bone, cement and implant interface as a major complication. The objective of this study was to evaluate the stabilization of the prosthesis using different thicknesses of cement layer. For this study 48 femurs from 24 dogs weighing over 15 kilograms were used. They were separated in four groups, the first group with eight femurs used a cement mantle from 1.0 to 1.5 mm, the second group, with eight femurs, used a cement mantle from 2.0 to 2.5 mm and the third group, with eight femurs, used a cement layer from 3.0 to 3.5 mm. The femurs were submitted to destructive torsion tests where they were evaluated due to the values of torsional rigidity and maximum torque shown by the implant, bone and bone cement interface. In the fourth group were the remaining intact femurs, they were evaluated using the same torsion test used on the other groups. The results were that under the present conditions we found no biomechanical differences relative to torsional rigidity and maximum torque, using cement layers between 1 mm and 2.5 mm and between 2 mm and 3.5 mm. But we found biomechanical differences between groups of 1 mm to 1.5 mm and 3 mm to 3.5 mm.
269

Influência da nitretação de superfície de titânio sobre a formação e desenvolvimento de biofilmes multiespécie = Influence of titanium nitride by cold-plasma on formation and development of multiespecies biofilms / Influence of titanium nitride by cold-plasma on formation and development of multiespecies biofilms

Cavalcanti, Indira Moraes Gomes, 1988- 22 August 2018 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T21:13:35Z (GMT). No. of bitstreams: 1 Cavalcanti_IndiraMoraesGomes_M.pdf: 1420347 bytes, checksum: 8abf0fb5ddb8408095a6916cf3badd0a (MD5) Previous issue date: 2013 / Resumo: Tratamentos que alteram propriedades de superfície de titânio são realizados em implantes odontológicos visando uma melhor sinalização celular e a neoformação óssea. Porém, em determinadas situações clínicas, as superfícies de titânio expostas ao meio oral recobertas por película adquirida (PA) podem se tornar substratos para o desenvolvimento de biofilmes associados às doenças inflamatórias, como a peri-implantite. Diante desta observação, os objetivos deste estudo foram (i) caracterizar a superfície de titânio nitretada por plasma a frio quanto às propriedades de rugosidade, topografia, composição química e energia livre de superfície (ELS); (ii) determinar o perfil protéico da PA adsorvida às superfícies (iii) avaliar a influência do tratamento de superfície na formação e desenvolvimento de biofilmes multiespécies. Para o estudo, discos de titânio grau IV receberam polimento e acabamento e foram divididos aleatoriamente no grupo controle (Ti) e experimental TiN (nitretado por plasma a frio). As superfícies foram caracterizadas através da microscopia eletrônica de varredura (MEV) e a rugosidade e topografia determinadas pela Microscopia de Força Atômica (n = 4). A ELS foi avaliada pela técnica ácido-base e leitura em goniômetro (n = 9) e a composição química da superfície foi determinada por Espectroscopia Fotoeletrônica de Raios-X (XPS) (n = 4). Em seguida, os discos foram imersos em saliva para formação de PA por 2 horas e novamente a ELS foi determinada (n = 6). O perfil protéico da PA foi determinado por espectrometria de massas LC-MS/MS (n = 18). Um biofilme composto por um fungo e seis bactérias (Candida albicans, Veillonella dispar, Streptococcus mutans, Streptococcus oralis, Fusubacterium nucleatum e Actinomyces naeslundii), foi desenvolvido durante 64,5 horas sobre os discos com película. Após este período, os micro-organismos e o biofilme total foram quantificados em células viáveis (n = 12). A topografia e a organização dos biofilmes foram analisadas por MEV e pela microscopia confocal a laser. Os dados de células viáveis e perfil protéico foram avaliados estatisticamente pelo Teste t de Student e os dados de ELS pela análise de variância (ANOVA) de dois fatores seguida pelo teste de Tukey com nível de significância de 5 %. Os resultados demonstraram não haver diferença entre as propriedades de rugosidade e topografia entre os grupos e um maior pico de nitrogênio foi detectado na composição química da superfície nitretada. O tratamento não alterou a ELS, que aumentou apenas na presença de PA (p < 0.001). Diferentes proteínas se adsorveram a superfície nitretada. A quantidade de células viáveis do biofilme formado nas duas superfícies foi semelhante (p = 0.416), confirmado pelas microscopias, porém Fusobacterium nucleatum e Streptococcus oralis foram quantificados em maior número nos biofilmes do grupo TiN. Conclui-se que a nitretação por plasma a frio não alterou as propriedades de superfície de titânio e não influenciou a quantidade de biofilme formado. Porém, a superfície nitretada aumentou as contagens de Fusobacterium nucleatum e Streptococcus oralis e selecionou diferentes proteínas na PA / Abstract: Surface treatments that alter titanium properties titanium are performed on dental implants in order to improve the cell signalization and bone formation. Although, in certain clinical situations, the surfaces exposed to oral cavity covered by acquired-pellicle (AP) may become substrates for development of biofilms associated with inflammatory diseases as periimplantitis. Given this observation, the aims of this study were (i) to characterize the surface properties of titanium nitride by cold plasma as roughness, topography, chemical composition and surface free energy (SFE), (ii) determine the protein profile of AP adsorbed to the surfaces (iii) evaluate the influence of surface treatment on formation and development of multispecies biofilms. For the study, titanium discs grade IV received polish and finish and were randomly allocated to control (Ti) and experimental TiN (nitride by cold-plasma) groups. The surfaces were characterized by scanning electron microscopy (SEM) and roughness and topography determined by Atomic Force Microscopy (n = 4). The SFE was evaluated using the acid-base technique and read in goniometer (n = 9). The surface chemical composition was determined by x-ray photo-electron spectroscopy (XPS) (n = 4). Then, the discs were immersed in saliva for AP formation per 2 hours and again the SFE was determined (n = 6). The AP protein profile was determined by mass spectrometry LC-MS/MS (n = 18). A biofilm composed by five bacteria and one fugal (Candida albicans, Veillonella dispar, Streptococcus mutans, Streptococcus oralis, Actinomyces naeslundii and Fusobacterium nucleatum) was conducted for 64.5 hours on coated-discs. After this period, the viable cells of biofilms were determined (n = 12). The biofilms topography and organization were analyzed by SEM and by confocal laser microscopy. The data of viable cells and protein profile were evaluated statistically by Student's t test and SFE data by two-way ANOVA followed by Tukey's test with a significance level of 5%. The results showed no difference between the properties of roughness and topography in groups. A high peak of nitrogen was detected in the chemical composition of the nitride surface. The treatment did not alter the SFE, that increased in the presence of AP (p <0.001). Different protein adsorbed to nitride surface. The amount of viable cells in the biofilm formed on both surfaces was similar (p = 0.416), confirmed by microscopies. The number of viable cells of Streptococcus oralis and Fusobacterium nucleatum were higher in TiN. It was concluded that the cold plasma nitriding did not alter the titanium surface properties and did not affect the amount of biofilm. However, it increased the counts of Fusobacterium nucleatum and Streptococcus oralis and selected different proteins in AP / Mestrado / Protese Dental / Mestra em Clínica Odontológica
270

Influência da concentração do ácido hidrofluorídrico e da ciclagem térmica na resistência da união entre cerâmica e cimento resinoso / Influence of the concentration of hydrofluoric acid and thermal cycling on bond strength between ceramic and resin cement

Sicoli, Eliseu Augusto, 1960- 07 November 2011 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T17:46:05Z (GMT). No. of bitstreams: 1 Sicoli_EliseuAugusto_D.pdf: 4658696 bytes, checksum: ce260af08392da02937030d7837080d4 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar o efeito do condicionamento com ácido hidrofluorídrico ( 5 e 10%) e ciclagem térmica na resistência ao microcisalhamento da interface cimento resinoso RelyX ARC - IPS E.max Press. Foram confeccionadas 20 amostras com cerâmica IPS E.max Press de acordo com a recomendação do fabricante. As amostras foram incluídas em tubos de PVC com resina epóxi e divididas em 4 grupos (n=40). Todas as amostras após o condicionamento ácido por 20 segundos foram silanizadas e a confecção dos corpos-de-prova seguiu o mesmo procedimento padrão para a cimentação com RelyX ARC. Os grupos foram separados em: 1- Cerâmica condicionada com ácido hidrofluorídrico a 10%; 2 - Cerâmica condicionada com ácido hidrofluorídrico a 10% e termociclada com 3000 ciclos; 3 - Cerâmica condicionada com ácido hidrofluorídrico a 5% e 4 -Cerâmica condicionada com ácido hidrofluorídrico a 5% e depois termociclada com 3000 ciclos. Após tratamento da superfície da cerâmica foi realizada aplicação de silano RelyX Ceramic Primer. Matrizes de silicone por adição com quatro perfurações de 1 mm de altura por 1 mm de diâmetro foram posicionadas sobre a cerâmica e preenchidas com o cimento RelyX ARC conforme os grupos citados. A fotoativação foi realizada com o aparelho LED UltraLume 5 com 1100 mW/cm2 de irradiância por 40 segundos. As amostras foram mantidas em 100% de umidade relativa a 37°C por 24 horas e levadas a máquina de ensaios Instron para o teste de microcisalhamento com velocidade de 0,5 mm/minuto. Os resultados em MPa (G1: 35,34±5,03; G2: 21,80±6,39; G3: 33,28±7,57; G4: 19,39±5,06) foram submetidos a análise de variância e as médias ao teste de Tukey (p<0,05). A análise estatística mostrou valor de resistência de união ao microcisalhamento significativamente superior para os grupos 1 e 3 (sem ciclagem térmica). Houve diferença estatisticamente significante em relação à concentração do ácido hidrofluorídrico com menor resistência ao microcisalhamento na concentração 5%. Não houve diferença estatística na interação entre os grupos. A análise do padrão de fratura mostrou predominância de fraturas adesivas em todos os grupos; embora os grupos 1 e 3 apresentassem fraturas do tipo coesiva no cimento em maior porcentagem quando comparados aos grupos 2 e 4. Assim concluiu-se que a ciclagem térmica diminuiu a resistência ao microcisalhamento da união adesiva, independentemente da concentração do ácido hidrofluorídrico e as falhas foram predominantemente adesivas / Abstract: The aim of this study was to evaluate the resistence to microshear bond strength from the bonding of cement ceramic IPS E.max Press with resin cement Rely X ARC under etching surface effect with hydrofluoridric acid in concentrations of 5% and 10%. The problems faced in the groups were also analysed. Twenty samples of ceramic were produced according to the manufacturer recommendation. The samples were included in PVC tubes with epoxi resin and separated in 4 groups (n=40). After the etching with acid for 20 seconds, the samples were silanized and the same cementing procedure was done with Rely X ARC. The groups were separated in: 1- Ceramic conditioned with hydrofluoridric acid in 10%; 2- Ceramic conditioned with hydrofluoridric acid in 10%, thermocycled in 3000 cycles with temperature between 5°C and 55°C and baths of 30s in each temperature; 3- Ceramic conditioned with hydrofluoridric acid in 5% and 4- Ceramic conditioned with hydrofluoridric acid in 10%, thermocycled in 3000 cycles with temperature between 5°C and 55°C and baths of 30s in each temperature. After the ceramic surface etching it was applied silane RelyX Ceramic Primer using microbrush. Silicone rubber matrices with four perfurations, 1 mm of thickness by 1 mm of diameter each, were put on the ceramic and fulfilled with Rely X ARC cement. The light activation was done using LED UltraLume 5 with 1100 mW/cm2 irradiation acting for 40 seconds. The samples were stored in environment with 100% relative humidity and 37°C for 24 hours. After this period they were submitted to the resistence test of microshear bond strength in the Instron equipament under 0,5 mm/minute of speed. The results in MPa (G1: 35.34±5.03; G2: 21.80±6.39; G3: 33.28±7.57; G4: 19.39±5.06) were submitted to analysis of variance and Tukey's test (p<0,05). The microshear bond strength resistence was significantly bigger for groups 1 and 3 (without thermocycling). There was statistically significant difference as to hydrofluoridric acid concentration. The concentration with 5% presented lower resistence to the microshear bond strength. The standard fracture analysis showed predominance of adhesive problems in all groups although groups 1 and 3 showed cohesive fractures in the cement with the biggest percentage when compared to groups 2 and 4. This way in conclusion the thermocycling decrease the resistence to microshear of the Bond union,independent of the hydrofluoridric acid concentration and the adhesive failures was predominant / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários

Page generated in 0.1293 seconds