• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1028
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 88
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Avaliação do uso de uma estrutura de nylon modificada como reforço de prótese totalmente acrílica implantossuportada /

Gonçalves, Fernanda de Cássia Papaiz. January 2015 (has links)
Orientador: Tarcísio José de Arruda Paes Júnior / Co-orientador: Vanessa Cruz Macedo / Banca: Alexandre Luiz Souto Borges / Banca: Estevão Tomomitsu Kimpara / Banca: Eduardo Miyashita / Banca: Mayra Cardoso / Resumo: O estudo avalou o comportamento de uma estrutura de nylon experimental com o propósito de ganho na resistência mecânica do material e ainda, na melhor distribuição de forças em toda extensão da prótese ao longo eixo dos implantes diminuindo o risco de fraturas e falhas neste sistema e, consequentemente maior longevidade. Para isso considerou-se próteses do tipo protocolo sem barra metálica, com e sem incorporação de reforço (nylon), variando a extensão da região do cantilever até primeiro molar/ segundo pré-molar (n=6). Os corpos de prova foram submetidos à análise de deformação por extensometria (extensometria s) e carga de 30 kg, e ao teste de carga máxima à fratura na EMIC (1000 kgf, 2 mm/min). Pode-se concluir que a incorporação da estrutura de reforço aumentou os valores de carga máxima independentemente da extensão do cantilever, além de apresentar menores valores de micro deformação ao redor de todos os implantes. As extensões de cantilever em pré-molar (5mm) além de apresentarem os menores valores de micro deformação quando comparadas a extensão em molar (15mm) também mostraram os maiores valores de carga máxima à fratura. / Abstract: The study evaluated the behavior of a new compound of experimental nylon fiber, with the purpose of increasing the mechanical strength of the material and improving the strain distribution to the fullest extent of the prosthesis to the long axis of the implants reducing the risk of fractures and faults in the system and therefore increasing longevity. For this considered protocol type prostheses without metal bar, with and without incorporating reinforcement (nylon), varying the extent of the region of the cantilever to the first molar / second premolar (n = 6). The samples were subjected to analysis by extensometer strain (extensometria ) and load of 30 kg, and the maximum load test to fracture the EMIC (1000 kgf, 2 mm / min). It can be concluded that the incorporation of reinforcing mesh increased maximum load values regardless of the extent of the cantilever, and exhibit lower values microstrain around all implants. The cantilever extensions in premolar (5 mm) in addition of having the smallest microstrain values compared the extent to molar (15mm) also showed the highest maximum load values to fracture / Doutor
252

Influência do tipo de pilar de resistência mecânica pré-ciclagem, quantidade de toque retido e desajuste vertical pré e pós-ciclagem, com análise estrutural em MEV /

Butignon, Luís Eduardo. January 2011 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Rafael Leonardo Xediek Consani / Banca: Luiz Fernando Pegoraro / Banca: Ana Carolina Pero / Banca: Regnata Garcia Fonseca / Resumo: Problemática: De ocorrência clínica comum, o afrouxamento dos parafusos que compõe uma prótese sobre implante é uma complicação que traz transtornos tanto para o profissional quanto para o paciente. Entre os fatores que interferem na estabilidade da união parafusada destaca-se a pré-carga gerada durante o torque do parafuso, as formas como as forças se dissipam através do conjunto implante/pilar/parafuso e as características dos componentes utilizados. Proposição: O objetivo deste estudo foi analisar comparativamente três tipos de pilares sobre implantes, quanto a resistência mecânica previamente ao ensaio de carga cíclica; a porcentagem de torque retido na união parafusada e os níveis de desajuste vertical entre o pilar e o implante antes e após ciclagem; e alterações estruturais na base de assentamento dos pilares através de microscopia eletrônica de varredura (MEV). Material e método: Quarenta e cinco implantes, com conexão tipo hexágono externo foram incluídos em cilindros de PVC utilizando-se resina epóxica com módulo de elasticidade semelhante à estrutura óssea. Os grupos foram estabelecidos de acordo com o tipo de pilar utilizado (n=15): Titânio (pré-fabricado), Ouro (com cinta metálica pré-fabricada e sobre fundido) e Zircônia (pré-fabricado). Cinco pilares de cada grupo foram submetidos a teste de resistência estática para estabelecimento do valor da força a ser utilizada no ensaio de carga cíclica. Os outros 10 pilares de cada grupo foram fixados sobre os respectivos implantes através de parafuso de titânio, sob torque e retorque de 32 Ncm (pilares metálicos) e 20 Ncm (pilar de zircônia). Os corpos de prova foram submetidos à aferição do torque retido (précarga) e dos níveis de desajuste vertical... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: The aim of this study was to evaluate comparatively three type of abutment in regard to mechanical resistance before cyclic loading, the maintenance of the applied torque and vertical misfit in abutment/implant interface before and after cyclic loading, and damage surface by SEM. Material and Method: Forty five external hex implants were embedded in an epoxy resin and received your respective abutments, randomly divided in three experimental groups (n=15): (A) machined titanium (Ti) abutments; (B) premachined gold (Au) abutments and (C) machined zirconia (ZrO2) abutments. For all groups, only one type of screw was used. The abutment screws were tightened according to the manufacture's recommended torque. Initially, a static bending test was performed using 5 specimens of each group to determine the load applied in the cyclic loading test. Thus, 10 specimens of each group were used to measure the reverse torque value (preload) of the abutment screw and vertical gap between the abutments and implant, before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106 cycles; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were compared using ANOVA and Tukey test. Result: The mechanical strength test showed that the UFL mean for Au abutments was significantly higher than the mean of the other abutments (p<0.001). The analysis of reverse torque (preload) before cyclic loading showed no significant differences among abutment groups. After cyclic loading the lowest decrease in preload was observed in group Ti, whereas the highest was observed in group ZrO2, with significant differences between them. The group Au showed an intermediate decrease, with no significant difference to the other groups. In relation to the vertical misfit... (Complete abstract click electronic access below) / Doutor
253

Estudo da resistência à tração de cápsulas e troqueis metálicos cimentados, em função de alívio e retenção para o cimento /

Pavanelli, Carlos Augusto. January 2002 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Eulália Maria Martins da Silva / Banca: Lafayette Nogueira Junior / Banca: Cícero Eleutério da Silva Filho / Banca: Marcos Yasunóri Maekawa / Resumo: O objetivo desta pesquisa foi estudar resistência à tração de cápsulas cimentadas sobre troqueis metálicos, com cimento fosfato de zinco, variando quantidade de alívio interno nas cápsulas e sulcos horizontais nas cápsulas e nos troqueis. Foram torneados duzentos e oitenta e oito cilindros de aço inoxidável, representativos de cento e quarenta e quatro troqueis e igual quantidade de cápsulas, semelhantes a preparos e respectivas coroas totais, em Torno tipo CNC (Controle Numérico Computadorizado). As dimensões padronizadas dos troqueis foram: 9mm de diâmetro na base maior (cervical); 8mm de altura cérvico-oclusal: terminação em ombro com um milímetro de largura e 135° de inclinação; e 10° de conicidade nas paredes axiais. As cápsulas foram obtidas por usinagem do interior de outros cilindros, com a forma idêntica e negativa em relação à forma dos troqueis. Quarenta e oito condições experimentais foram estabelecidas e cimentadas, em três réplicas para cada condição. O alívio das cápsulas foi de 2µm (na condição sem alívio), 30µm e 60µm (nas condições com alívio). A confecção de sulcos variou entre zero e três sulcos, nas cápsulas e nos troqueis, com 200µm de profundidade e em quantidades iguais de espécimes para cada condição estudada. Assim, as condições experimentais somente se repetiram nas réplicas. Os corpos-de-prova obtidos das cimentações foram submetidos a teste de tração em máquina universal de ensaios Emic (ltaquaquecetuba-SP), no Departamento de Materiais e Tecnologia da Faculdade de Engenharia de Guaratinguetá, UNESP. Os resultados receberam tratamento estatístico pelos métodos de, Análise de Variância e de Tukey, mostrando diferença significativa ao nível de 5% para as variáveis alívio e sulco nas cápsulas individualmentee quando esses fatores interagiram. Não houve diferença estatística para a variável sulco nos troqueis. A permaneceu sem alteração com os... / Abstract: The objective of this study was to verify tensile strength of metallic capsules and dies, in stainless steel, cemented with zinc phosphate cement, representative of crowns and full crowns preparations. One hundred and forty four dies and respective capsules were made in Lathe CNC (Computer Numeric Control). The dimensions of the dies were: 9mm of diameter ín the base (gingival); 8mm of height; cervical line in shoulder with one millimeter of width and 135 degrees of inclination; and tapered of 10 degrees. The capsules were excavated in the interior of other cylinders, with the tapered form, identical and negative in relation to the form of the dies. Forty-eight experimental conditions, in three rejoinders each, were made. The changeable were: internal relief in the capsules; and horizontal sulcus in the capsules and the dies. The relief varied between 2µm (in the condition without relief), 30µm and 60µm (in the conditions with relief). The sulcus varied between no sulcus and three sulcus, as much in the capsules as in the dies, with 200 µm depth, in equal amounts of specimens for each condition of sulcus. The capsules and dies were cemented. The experimental conditions were not repeated, except in the rejoinders. The specimens were submitted to traction test in universal test machine of Emic (ltaquaquecetuba-SP) in the Department of Materials and Technology of the College of Engineering of Guaratinguetá, UNESP. The data were submitted to statistic analysis for methods ANOVA and Tukey, showing significant dífference for the variable relief and sulcus in the capsules, and interacting individually and among then. They had not presented difference statistics for changeable the sulcus in the dies. The tensile strength increased with the relief and the amount of sulcus in the capsules, but it remained in the same level with the sulcus in the dies / Doutor
254

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS) /

Gregolin, Rafael Ferreira. January 2013 (has links)
Orientador: Ruis Camargo Tokimatsu / Banca: João Antonio Pereira / Banca: Cecilia Amelia de Carvalho Zavaglia / Resumo: A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços - engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Abstract: Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it's used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS® / Mestre
255

Precisão de moldagens para implantes inclinados em maxila utilizando diferentes métodos de união de transfrentes e dois tipos de guias multifuncionais /

Araújo, Raphael Ferreira de Souza Bezerra. January 2015 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Pedro Cesar Garcia de Oliveira / Banca: José Maurício dos Santos Nunes Reis / Resumo: Este estudo objetivou analisar a precisão de diferentes métodos de união de transferentes em moldagem sobre implantes utilizando guias multifuncionais em reabilitações orais de maxilas com implantes hexágono externo. Para as técnicas de moldagem com dois tipos de guia multifuncional (com e sem patalo) foi comparado diferentes métodos de união dos transferentes: transferentes unidos com metal e resina acrílica, transferentes unidos apenas com resina acrílica e transferentes sem união. Uma barra metálica passiva fabricada sobre o modelo mestre foi parafusado nos modelos de gesso no análogo A e realizado a mensuração 3 vezes da fenda presente nos análogos C e D. Posteriormente a barra é parafusado no análogo D e realizada a mensuração 3 vezes da fenda nos análogos A e B, utilizando um programa de análise de imagens (Leica QWin) que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa Leica (100X). Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independentemente da técnica de união dos transferentes. Porém, só houve diferenças estatísticas quando comparado à técnica de moldagem OM=203,04µm (guia multifuncional com palato aberto e transferentes unidos com metal e resina acrílica) com às técnicas de moldagem PR=151,61µm (guia multifuncional com cobertura de palato e transferentes unidos com resina acrílica) e com o modelo Mestre (MM=142,78µm). Considerando as limitações desse estudo pode-se sugerir que a utilização da técnica de moldagem OM gera os modelos menos precisos. / Abstract:This study analyze "in vitro" the accuracy of different union transfers methods in impressiom using multifunctional guides for prosthetic rehabilitation in a toothless jaw with external hexagon implants installed. For the impression techniques with two types of multifunctional guide (palate coverage and open palate) it was compared different methods of union of the square transfers: metal splinted transfers, acrylic resin splinted transfers and without splinted transfers. A metal structure fabricated on the master model with passive fit was screwed in the models obtained, on A analogue while measurements were made 3 times on analogs C and D and when screwed into analog D measurements were made 3 times in analogues A and B, by a image analysis software (Leica QWin) that received the images from a video camera attached to a Leica magnifier (100X). After verification of distribution and homoscedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of splint techniques. But only exist statistical differences when compared the impression technique OM = 203,04µm (multifunctional guide with open palate and transfers splinted with metal and acrylic resin) with impression technique PR = 151,61µm (multifunctional guide with coverage palate and transfers splinted with resin acrylic) and the master model (MM = 142,78µm). Considering the limitations of this study may suggest that the use of OM molding technique generates less accurate models. / Mestre
256

Efeito da desinfecção química e do envelhecimento acelerado sobre a estabilidade dimensional, reprodução e manutenção de detalhes e estabilidade de cor do silicone facial Silastic MDX 4-4210 com opacificador /

Haddad, Marcela Filié. January 2010 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Aline Úrsula Rocha Fernandes / Resumo: Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução de detalhes e estabilidade de cor de silicone facial, com adição ou não de pigmento e opacificador; sob influência da desinfecção química e do envelhecimento acelerado. Para isso, foram obtidas 120 amostras, utilizando o silicone Silastic MDX 4-4210, divididas em 4 grupos contendo 30 amostras cada, sendo GI - incolor, GII - pigmentado com pó de cerâmica, GIII - com adição de sulfato de bário (opacificador) e GIV- pigmentado com pó de cerâmica e sulfato de bário. Dez amostras de cada grupo foram desinfetadas com uma das três substâncias a seguir: pastilhas efervescentes a base de peróxido alcalino, sabão neutro ou clorexidina. O processo de desinfecção química foi realizado três vezes por semana, durante 60 dias. Após esse período, todas as amostras foram submetidas ao envelhecimento acelerado. Os testes de estabilidade dimensional, reprodução de detalhes e estabilidade de cor foram realizados no período inicial, após 60 dias de desinfecção e, nos intervalos de 252, 504 e 1008 horas de envelhecimento acelerado. As amostras foram analisadas em computador pelo sistema AutoCAD para verificação da alteração dimensional linear; e observadas em lupa estereoscópica para a análise da reprodução de detalhes. A estabilidade de cor foi verificada por meio de espectrofotometria de reflexão. Os valores obtidos nos testes de estabilidade dimensional e estabilidade cromática foram submetidos à análise de variância e teste de Tukey (p<0,05). Para a análise da reprodução e manutenção de detalhes foi utilizado escore de 0 a 2. O fator desinfecção não influenciou estatisticamente nos valores de estabilidade dimensional, reprodução de detalhes e estabilidade de cor do silicone, independente da... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated aging. 120 samples were obtained, using Silastic MDX 4-4210 elastomer, divided in 4 groups with 30 samples: GI - colorless, GII - pigmented with ceramics, GIII - pigmented with barium sulfate opacifier, and GIV - pigmented with ceramics and barium sulfate opacifier. Ten samples of each group was submitted to the disinfection with effervescent tablets, with neutral soap or 4% chlorhexidine, three times a week during 60 days. After this period all samples were taken to a chamber of accelerated aging for not metallic bodies. The tests of dimensional stability, maintenance of the details, and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated aging (252, 504 e 1008 hours). Samples were analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. The color stability was analyzed by means of spectrophotometer. The dimensional alteration and color stability values had been submitted to the analysis of variance and Tukey test (p<0.05). For the analysis of detail reproduction, the 0 -2 scores were used It can be observed that the factor: chemical disinfection had no influenced statistically on dimensional stability, detail reproduction and color stability values. Accelerated aging had influenced statistically on dimensional stability values after 1008 hours. About detail reproduction, all samples exhibited score 2 for all analyzed periods. Pigment and opacifier association was more stable for chromatic stability test in all analyzed... (Complete abstract, click electronic address below) / Mestre
257

Avaliação biomecânica da fixação das endopróteses com e sem cola biológica e alterações histológicas aórticas. Estudo experimental em porcos

Almeida, Marcelo José de [UNESP] 15 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-09-15Bitstream added on 2014-06-13T19:19:08Z : No. of bitstreams: 1 almeida_mj_dr_botfm.pdf: 527680 bytes, checksum: b40e49ce6cd134912d0e53aa6e29defc (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A migração da endoprótese é uma complicação do tratamento endovascular definida como deslocamento de sua ancoragem inicial. Para avaliação da migração verifica-se a posição da endoprótese em relação à determinada região anatômica. Considerando o aneurisma da aorta abdominal infra-renal, a área proximal de referência consiste na origem da artéria renal mais baixa e, na região distal, situa-se nas artérias ilíacas internas. Os pacientes deverão ser monitorizados por longos períodos a fim de serem identificadas migrações visto que estas ocorrem normalmente após 2 anos de implante. Para se evitarem migrações, forças mecânicas que propiciam fixação e determinadas por características dos dispositivos e a incorporação da endoprótese, devem predominar sobre forças gravitacional e hemodinâmica que tendem a arrastar a prótese no sentido caudal. Angulação, extensão e diâmetro do colo, além da medida transversa do saco aneurismático, são importantes aspectos morfológicos do aneurisma relacionados à migração. Com relação à técnica, o implante de endopróteses com sobredimensionamento excessivo (>30%) não é recomendado por provocar dilatação do colo do aneurisma, além de dobras e vazamentos proximais que também contribuem para migração. Por outro lado, endopróteses com mecanismos adicionais de fixação (ganchos, farpas e fixação supra-renal) parecem estar menos associadas às migrações. O processo de incorporação das endopróteses ocorre parcialmente e parece não ser suficiente para impedir migrações tardias. Neste sentido, estudos experimentais com endopróteses de maior porosidade e uso de substâncias que permitam maior fibroplasia e aderência da prótese à artéria vem sendo realizados e parecem ser promissores. Nesta revisão estes aspectos serão discutidos, em especial o uso da cola de fibrina. / Migration of the endoprosthesis is a complication of the endovascular treatment defined as misplacement of its initial fixation. In order to assess such migration, one shall verify the position of the endoprosthesis in relation to the determined anatomic site. Considering the aneurysm of the infra-renal abdominal aorta, the proximal area of reference consists on the origin of the lowest renal artery and, at the distal region, it is located next to the internal iliac arteries. Patients shall be monitored for long periods so that migrations can be spotted; these migrations usually occur 2 years after the implant. To avoid migration mechanical forces that enable fixation and that are determined by features of devices as well as the incorporation of the endoprosthesis have to predominate over gravitational and hemodynamic forces, which tend to drag the prosthesis toward to caudal direction. Angulation, extension and diameter of the neck, and transversal measure of the aneurysmatic sac, are important morphological aspects related to migration. In relation to technique, the implant of endoprosthesis with excessive oversizing (>30%) is not recommended because it leads to aortic neck dilatation, folds and proximal leaking witch contribute to its migration. On the other hand, endoprosthesis with additional fixation devices (hooks, barbs and supra-renal fixation) seem to be less associated with migration. The process of incorporation of the endoprosthesis occurs partially and does not seem to be enough to prevent later migrations. In this sense, experimental assessment with higher porosity endoprosthesis as well as the use of substances that allow higher fibroplasia and adherence of the prosthesis to the artery have been made and look promising. In this review, such aspects are discussed, specially the use of fibrin glue.
258

Efeitos da terapia fotodinÃmica mediada por um novo dispositivo de luz comparada a compostos quÃmicos indicados para descontaminaÃÃo da resina acrÃlica / Effects of photodynamic therapy mediated by a new light device compared to chemical compounds indicated for descontamination of acrylic resins

Janaina CÃncio de Holanda Prado 08 July 2015 (has links)
A desinfecÃÃo ou esterilizaÃÃo de dispositivos de resina acrÃlica, como prÃteses imediatas, guias e goteiras cirÃrgicas, à importante na prevenÃÃo da contaminaÃÃo do paciente por micro-organismos potencialmente patogÃnicos. As resinas acrÃlicas sÃo materiais termossensÃveis, podendo somente ser descontaminadas por meios quÃmicos ou frios. Esta dissertaÃÃo teve como objetivos fazer uma revisÃo de literatura sistemÃtica sobre a aÃÃo antimicrobiana de agentes quÃmicos em resinas acrÃlicas, alÃm de realizar um estudo experimental avaliando o efeito da terapia fotodinÃmica, mediada pelo fotossensibilizador azul de metileno a 22 &#956;M, sobre o nÃvel de contaminaÃÃo por micro-organismos presentes em prÃteses totais advindas de diferentes laboratÃrios protÃticos, bem como um novo equipamento composto por diodos emissores de luz (LEDs) de 630 nm e 1W. Para a revisÃo de literatura foram utilizados os descritores ÂÂmicroorganismsÂÂ, ÂÂdental prosthesisÂÂ, e/ou ÂÂdisinfection nas bases de dados Pubmed/ Bireme, com busca no perÃodo de 2004 a 2014, incluindo artigos em inglÃs referentes a pesquisas experimentais, comparando-se agentes quÃmicos sobre mais de uma espÃcie de micro-organismo, na superfÃcie de resinas acrÃlicas. Foi verificado que os mÃtodos apresentaram variaÃÃes nos efeitos antimicrobianos, dependendo do tempo de imersÃo, concentraÃÃo do produto e a espÃcie de micro-organismo presente. O hipoclorito de sÃdio 1%, o digluconato de clorexidina 2% e o Ãcido acÃtico apresentaram maior eficÃcia, em ordem decrescente. No estudo experimental, foram selecionadas 25 prÃteses totais superiores precedendo a instalaÃÃo nos pacientes. Em seguida, as mesmas foram aleatoriamente distribuÃdas por sorteio em quatro grupos: sem tratamento; imersÃo em digluconato de clorexidina 2% por 10 minutos; apenas irradiaÃÃo com LEDs; terapia fotodinÃmica (TFD). O circuito de controle e acionamento do equipamento composto por 8 LEDs de 1W foi desenvolvido em parceria com o LaboratÃrio de Engenharia de Sistema de ComputaÃÃo, na Faculdade de Engenharia de TeleinformÃtica da Universidade Federal do CearÃ. No grupo TFD, a irradiaÃÃo por 1 minuto ocorreu depois de 5 minutos da aplicaÃÃo do fotossensibilizador. ApÃs os tratamentos realizados, as prÃteses foram imersas em 100 ml de BHI caldo e levadas à cuba ultrasÃnica por 15 minutos. Foram coletados 5 ml deste meio de cultura para incubaÃÃo por 48 horas a 37ÂC. Em seguida, 1000 microlitros do caldo foram diluÃdos em 1:10, 1:100, 1:1000 e plaqueados em triplicada, em Ãgar Sangue, Ãgar Sabouraud Dextrose, e Hicrome UTI ÃgarÂ. As placas foram incubadas a 37ÂC por 48 horas, para posterior contagem de unidades formadoras de colÃnia (UFC/ml) e classificaÃÃo dos dados em escala ordinal. Testes de Kruskall-Wallis, Dunn, ANOVA (2 critÃrios) e Bonferroni (&#945;=0,05) foram aplicados. A TFD mostrou reduÃÃo significativa na contagem de bactÃrias totais viÃveis (p=0,0002), quando comparada ao grupo somente irradiado, e reduÃÃo significativa de fungos totais viÃveis, quando comparada aos grupos sem tratamento e somente irradiado (p=0,0002). A TFD teve efeito antimicrobiano semelhante à imersÃo em digluconato de clorexidina 2% por 10 minutos (p>0,05). As espÃcies bacterianas identificadas mais prevalentes nas prÃteses foram P. aeruginosa, K. pneumoniae e E. coli e a TFD promoveu diminuiÃÃo significativa na contagem destas espÃcies, assim como a clorexidina (p<0,001). A contaminaÃÃo de prÃteses dentÃrias advindas de laboratÃrios protÃticos foi expressiva. A terapia fotodinÃmica empregada no protocolo proposto para dispositivos de resina acrÃlica mostrou efeito antimicrobiano promissor mediante esta contaminaÃÃo. / Disinfection or sterilization of acrylic resin devices, such as immediate prostheses, surgical guides and gutters, is important in preventing the patient from contamination by potentially pathogenic microorganisms. Acrylic resins are heat-sensitive materials, which can only be decontaminated by chemicals or cold means. This study aimed at making a systematic review of literature on the antimicrobial action of chemical agents on acrylic resins. In addition, it was carried out an experimental study evaluating the effect of photodynamic therapy, mediated by methylene blue photosensitizer to 22 &#956;M, on the level of contamination by microorganisms present in dentures coming from different laboratories, and a new device consisting of light emitting diodes (LEDs) 630 nm and 1W. For the literature review, we used the descriptors microorganisms, dental prosthesis, and/or disinfection in Pubmed/ Bireme databases with search from 2004 to 2014, including articles in English on experimental studies comparing chemical agents on more than one species of microorganism in the surface of acrylic resin. It was found that methods show differences in antimicrobial effects depending on the immersion time, product concentration and type of present microorganism. Sodium hypochlorite 1%, chlorhexidine digluconate 2% and acetic acid showed greater efficacy, in decreasing order. In the experimental study, a number of 25 upper dentures were selected and installed in patients. Then, the dentures were randomly distributed into four groups: untreated; immersion in 2% chlorhexidine digluconate for 10 minutes; only irradiation with LEDs; photodynamic therapy (PDT). The control circuit and activation of equipment consisting of 8 LEDs 1W was developed in partnership with the Computer System Engineering Laboratory at the Faculty of Computer Engineering at the Federal University of CearÃ. On the PDT group, irradiation for 1 minute took place 5 minutes after application of the photosensitizer. After the treatment, the prostheses were immersed in 100 ml of BHI broth and then brought to ultrasonic tank for 15 minutes. It was collected 5 ml of this culture for incubation for 48 hours at 37  C. After that, 1000 microliter of the broth were diluted 1:10, 1: 100, 1: 1000 and plated in triplicate, on Blood Agar, Sabouraud Dextrose Agar and HiCrome UTI ÃgarÂ. The plates were incubated at 37ÂC for 48 h and then counting colony forming units (CFU / ml) and classification of data on an ordinal scale. Kruskal-Wallis test, Dunn, ANOVA (2 criteria) and Bonferroni (&#945; = 0.05) were applied. PDT showed significant reduction in count of total viable bacteria (p = 0.0002) compared to only irradiated group, and a significant reduction of total viable fungi, when compared to the only irradiated groups and untreated (p = 0.0002). PDT showed antimicrobial effect similar to immersion in 2% chlorhexidine digluconate for 10 minutes (p> 0.05). The most prevalent bacterial species identified in the prostheses were P. aeruginosa, K. pneumoniae and E. coli and PDT caused a significant decrease in counting of these species as well as chlorhexidine did (p <0.001). The contamination of dental prostheses coming from prosthetic laboratories was significant. Photodynamic therapy used in the proposed protocol for acrylic resin devices showed promising antimicrobial effect by this contamination.
259

Desenvolvimento de uma nova prótese para substituição de disco da coluna vertebral lombossacra através da metalurgia do pó

Souza, Alexandre Reus Baroni de January 2009 (has links)
O presente trabalho desenvolveu uma nova prótese para substituição de disco da coluna vertebral lombossacra, dividido em três macros etapas. Primeira etapa: conceito biomecânico e projeto assistido por computador (CAD/CAE), simulando estruturalmente o modelo virtual do implante. Segunda etapa: análise dos processos de fabricação, metalurgia do pó convencional (MPC) e por moldagem de pós por injeção (MIM), avaliando seus parâmetros. Terceira etapa: seleção do processo que mais se adaptou ao desenvolvimento de um implante, até a produção do protótipo de um implante. Foi utilizado pó comercialmente puro (99,5% Ti), com morfologia lamelar. A metalurgia do pó convencional (MPC) foi a selecionada para a fabricação do protótipo da nova prótese, compactada a 600 MPa e sinterizada a 1100°C durante 3h, neste patamar. O limite de elasticidade após a sinterização dos corpos de prova foi superior a 600 MPa, com densidade próxima a 4,04g/cm³. A porosidade foi avaliada por comparação volumétrica e imagens obtidas em MEV. Posteriormente foi analisada em software de processamento de imagens em diferentes regiões das amostras. A porosidade foi obtida por dois métodos: o primeiro considerou a imagem de uma superfície da amostra seguida pela variação da densidade em "bulk". O resultado da porosidade ficou entre 100µm e 500µm, faixa considerada adequada para a vascularização e crescimento ósseo. Foi aplicado uma carga de 3400N no modelo virtual do implante e a tensão resultante ficou abaixo de 60MPa. O resultado médio das densidades dos protótipos por Arquimedes do implante fabricados, foi de 4,05g/cm³. / The present study developed a new prosthesis to replace lumbosacral disks. It was divided in three steps. First step: biomechanical concept and computer assisted project (CAD/CAE), simulating the structure of the virtual model of the implant. Second step: analysis of manufacture process, conventional powder metallurgy (PM) and powder molding through injection, evaluating its parameters. Third step: selection of the process which best adapted to the development of an implant, up to the production of the implant prototype. Commercially pure powder (99,5% Ti) with lamellar morphology was used. Conventional powder metallurgy was selected to manufacture the new prosthesis, compacted at 600 MPa and sintered at 1100°C for 3 hours. The limit of elasticity after billets were sintered was above 700 MPa, and the density around 4,04g/cm³. Porosity was evaluated through images obtained in a SEM which were later analyzed by an image processing software in different parts of the billets. The result of porosity was between 100µm and 500µm, an adequate range for vascularization and bone growth. A charge of 3400N was applied to the virtual model of the implant and the resulting tension was under 60MPa. The resulting density in the manufactured prototypes was 4,05g/cm³, on average.
260

Análise tridimensional por elementos finitos da biomecânica de próteses implantossuportadas = influência da carga oclusal, tipo de conexão, angulação dos implantes e simplificações de modelagem / Tridimensional finite element analysis of biomechanics of implant-supported prosthesis : influence of occlusal load, implant connection system, implant tilting and modeling simplifications

Takahashi, Jessica Mie Ferreira Koyama 17 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:47:37Z (GMT). No. of bitstreams: 1 Takahashi_JessicaMieFerreiraKoyama_D.pdf: 2653820 bytes, checksum: 9f12264a20dcd2dbebcecc54655dd900 (MD5) Previous issue date: 2011 / Resumo: O objetivo nos presentes estudos foi avaliar, por meio de análise tridimensional de elementos finitos, os efeitos nos valores e padrões de distribuição de tensões de modelo virtuais de próteses implantossuportadas na presença de: 1) Simplificações de modelagem das geometrias de superfícies com rosca; 2) Variação do padrão de cargas oclusais e tipo de conexão de implantes; 3) Inclinação do implante e necessidade do uso de componentes angulados. No primeiro estudo foram confeccionados modelos virtuais simulando a interface entre o osso de uma seção posterior de mandíbula e um implante, e a interface entre o componente protético e o parafuso protético. As interfaces foram simuladas com variação da geometria das roscas e tipo de contato entre as estruturas. Os modelos da interface osso/implante receberam carga oblíqua de 180N, e os da interface abutment/parafuso carga de 41N. Foi observado, na interface implante/osso, que os valores de tensão variam de acordo com a geometria modelada e o contato entre as estruturas e que tensões artificialmente elevadas podem ser observadas em regiões pontuais. Na interface abutment/parafuso, a geometria modelada não influenciou os resultados obtidos. No segundo estudo, foram confeccionados modelos virtuais simulando próteses fixas suportadas por implantes de conexão do tipo hexágono externo, hexágono interno, e cone morse; submetidos à aplicação de cargas axiais ou oblíquas sobre a superfície da infraestrutura modelada (180N em primeiro pré-molar e primeiro molar; 280N em segundo pré-molar). Foi observado que mediante aplicação de cargas oblíquas os valores de tensão apresentaram aumento significativo, e que o local de concentração das tensões também foi alterado para regiões mais inferiores nas estruturas avaliadas. Os modelos de montagens com implantes de conexão interna apresentaram padrão de distribuição de tensão mais favorável aos tecidos de suporte. No terceiro estudo, modelos virtuais de próteses fixas implantossuportadas foram simulados com implantes distais posicionados de maneira inclinada. Os modelos foram confeccionados utilizando conexões do tipo hexágono externo e cone morse, sendo utilizados componentes com 17o de angulação. Os modelos foram submetidos às mesmas condições de carregamento citadas no estudo anterior. Foi observado que mediante inclinação dos implantes distais, não há diferença significativa nos valores de tensão nos tecidos de suporte, havendo apenas alteração na área de concentração de tensão. A tensão foi mais concentrada no osso trabecular ao redor do implante posicionado verticalmente. As conexões avaliadas apresentaram valores de tensão semelhantes nos tecidos de suporte, enquanto os modelos de conexão cone morse apresentaram maior tensão nos componentes protéticos. Desta maneira, concluiu-se que: 1) a simplificação da geometria de roscas para análise utilizando o método de elementos finitos gera valores e padrão de distribuição de tensão confiáveis; 2) a aplicação de cargas oblíquas gera aumento significativo na tensão nas estruturas ósseas; 3) o tipo de conexão do implante pode interferir na tensão em componentes protéticos e osso; 4) a inclinação de implantes não gera maior tensão nos tecidos de suporte. / Abstract: The aim of the following studies was to evaluate with finite element analysis, the effect on stress values and distribution pattern of virtual models of implant-supported prostheses in the presence of: 1) Modeling simplification of threaded surfaces geometry; 2) Variation of occlusal load pattern and implant connection type; 3) Implant inclination and the use of angled abutments. On the first study, virtual three-dimensional models were obtained simulating the interface between bone of a posterior section of the lower jaw and a dental implant, and the interface between an abutment and a prosthetic screw. The screwed interfaces were simulated with variation of thread geometry and contact between the structures. Bone/implant models were loaded with 180N oblique force, while abutment/screw models were loaded with 41N force. It was observed, on the implant/bone interface that stress values depend of the modeled geometry and the amount of contact between the surfaces; and that artificially high stress might be observed in located areas. On the abutment/screw interface, modeled geometry did not influence the results. For the second study, virtual models were obtained simulating three-element fixed partial dentures supported by two implants of external-hexagon, internal-hexagon or morse-taper connection. The models were submitted to axial or oblique loading (180N on first premolar and first molar, 280N on second premolar). It was observed that oblique loading significantly increased stress values, and changed stress concentration areas. Also, the models with internal connection implants presented stress distribution pattern more favorable to the supporting structure. On the third and final study, virtual models of implant-supported frameworks were obtained with inclined distal implants with external-hexagon or morse-taper connection and 17o angled abutment. All models were submitted to the same loading conditions previously described. It was observed that inclined implants do not significantly increase stress on supporting tissue, with changes only on stress concentration area. Higher stress was concentrated at trabecular bone around the straight implant. The evaluated connection systems presented similar stress values on the supporting tissue, while morse-taper models presented higher stress on the prosthetic components than the external-hexagon. Thus, it was concluded that: 1) finite element models, with simplified representation of the thread interface present reliable stress values and distribution patterns; 2) oblique loading of the framework increases stress values on the supporting tissues; 3) implant connection system may interfere on stress on prosthetic components and bone; 4) implant inclination does not increase stress on supporting tissue. / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.2126 seconds