• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1027
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 88
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Desenvolvimento de uma nova prótese para substituição de disco da coluna vertebral lombossacra através da metalurgia do pó

Souza, Alexandre Reus Baroni de January 2009 (has links)
O presente trabalho desenvolveu uma nova prótese para substituição de disco da coluna vertebral lombossacra, dividido em três macros etapas. Primeira etapa: conceito biomecânico e projeto assistido por computador (CAD/CAE), simulando estruturalmente o modelo virtual do implante. Segunda etapa: análise dos processos de fabricação, metalurgia do pó convencional (MPC) e por moldagem de pós por injeção (MIM), avaliando seus parâmetros. Terceira etapa: seleção do processo que mais se adaptou ao desenvolvimento de um implante, até a produção do protótipo de um implante. Foi utilizado pó comercialmente puro (99,5% Ti), com morfologia lamelar. A metalurgia do pó convencional (MPC) foi a selecionada para a fabricação do protótipo da nova prótese, compactada a 600 MPa e sinterizada a 1100°C durante 3h, neste patamar. O limite de elasticidade após a sinterização dos corpos de prova foi superior a 600 MPa, com densidade próxima a 4,04g/cm³. A porosidade foi avaliada por comparação volumétrica e imagens obtidas em MEV. Posteriormente foi analisada em software de processamento de imagens em diferentes regiões das amostras. A porosidade foi obtida por dois métodos: o primeiro considerou a imagem de uma superfície da amostra seguida pela variação da densidade em "bulk". O resultado da porosidade ficou entre 100µm e 500µm, faixa considerada adequada para a vascularização e crescimento ósseo. Foi aplicado uma carga de 3400N no modelo virtual do implante e a tensão resultante ficou abaixo de 60MPa. O resultado médio das densidades dos protótipos por Arquimedes do implante fabricados, foi de 4,05g/cm³. / The present study developed a new prosthesis to replace lumbosacral disks. It was divided in three steps. First step: biomechanical concept and computer assisted project (CAD/CAE), simulating the structure of the virtual model of the implant. Second step: analysis of manufacture process, conventional powder metallurgy (PM) and powder molding through injection, evaluating its parameters. Third step: selection of the process which best adapted to the development of an implant, up to the production of the implant prototype. Commercially pure powder (99,5% Ti) with lamellar morphology was used. Conventional powder metallurgy was selected to manufacture the new prosthesis, compacted at 600 MPa and sintered at 1100°C for 3 hours. The limit of elasticity after billets were sintered was above 700 MPa, and the density around 4,04g/cm³. Porosity was evaluated through images obtained in a SEM which were later analyzed by an image processing software in different parts of the billets. The result of porosity was between 100µm and 500µm, an adequate range for vascularization and bone growth. A charge of 3400N was applied to the virtual model of the implant and the resulting tension was under 60MPa. The resulting density in the manufactured prototypes was 4,05g/cm³, on average.
232

Protese ocular individualizada em resina acrílica com esfera oca

Oliveira, Simone Helena Gonçalves de [UNESP] 26 July 1995 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:47Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-07-26. Added 1 bitstream(s) on 2015-12-10T14:28:08Z : No. of bitstreams: 1 000026551.pdf: 1739809 bytes, checksum: 96937536447eb6f4c94bc8e2631f4167 (MD5) / A técnica proposta visa conseguir uma diminuição de peso das próteses oculares individualizadas amplas de resina acrílica, com passos laboratoriais simplificados. Para isso utilizaram-se esferas ocas pré fabricadas de material plástico, que são incluídas dentro da esclera. Compararam-se os pesos médios de escleras maciças convencionais (5,30g) com os de escleras com esferas ocas pré-fabricadas de material plástico (3,91g), respectivamente. A redução de peso foi significante com intervalo de confiança de 95% pelo teste t de Student. Foi também executada a técnica, a título de ilustração, em pacientes do Ambulatório da Disciplina de Prótese Buco-Maxilo-Facial da Faculdade de Odontologia do Câmpus de São José dos Campos-Unesp, tendo cada paciente recebido uma prótese maciça e uma prótese com esfera oca pré-fabricada de material plástico. Concluiu-se que as próteses e as escleras que possuem no seu interior a esfera oca pré-fabricada de material plástico são mais leves que as escleras maciças e que a técnica é viável para cavidades anoftálmicas amplas e é praticada em poucas sessões / The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the Student t test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions
233

Estudo da resistência à tração de cápsulas e troqueis metálicos cimentados, em função de alívio e retenção para o cimento

Pavanelli, Carlos Augusto [UNESP] 08 May 2002 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:24:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-05-08. Added 1 bitstream(s) on 2015-12-10T14:30:39Z : No. of bitstreams: 1 000164795.pdf: 4680235 bytes, checksum: 7ff12a7d0689d90c62b277df5ac9ca92 (MD5) / O objetivo desta pesquisa foi estudar resistência à tração de cápsulas cimentadas sobre troqueis metálicos, com cimento fosfato de zinco, variando quantidade de alívio interno nas cápsulas e sulcos horizontais nas cápsulas e nos troqueis. Foram torneados duzentos e oitenta e oito cilindros de aço inoxidável, representativos de cento e quarenta e quatro troqueis e igual quantidade de cápsulas, semelhantes a preparos e respectivas coroas totais, em Torno tipo CNC (Controle Numérico Computadorizado). As dimensões padronizadas dos troqueis foram: 9mm de diâmetro na base maior (cervical); 8mm de altura cérvico-oclusal: terminação em ombro com um milímetro de largura e 135° de inclinação; e 10° de conicidade nas paredes axiais. As cápsulas foram obtidas por usinagem do interior de outros cilindros, com a forma idêntica e negativa em relação à forma dos troqueis. Quarenta e oito condições experimentais foram estabelecidas e cimentadas, em três réplicas para cada condição. O alívio das cápsulas foi de 2µm (na condição sem alívio), 30µm e 60µm (nas condições com alívio). A confecção de sulcos variou entre zero e três sulcos, nas cápsulas e nos troqueis, com 200µm de profundidade e em quantidades iguais de espécimes para cada condição estudada. Assim, as condições experimentais somente se repetiram nas réplicas. Os corpos-de-prova obtidos das cimentações foram submetidos a teste de tração em máquina universal de ensaios Emic (ltaquaquecetuba-SP), no Departamento de Materiais e Tecnologia da Faculdade de Engenharia de Guaratinguetá, UNESP. Os resultados receberam tratamento estatístico pelos métodos de, Análise de Variância e de Tukey, mostrando diferença significativa ao nível de 5% para as variáveis alívio e sulco nas cápsulas individualmentee quando esses fatores interagiram. Não houve diferença estatística para a variável sulco nos troqueis. A permaneceu sem alteração com os... / The objective of this study was to verify tensile strength of metallic capsules and dies, in stainless steel, cemented with zinc phosphate cement, representative of crowns and full crowns preparations. One hundred and forty four dies and respective capsules were made in Lathe CNC (Computer Numeric Control). The dimensions of the dies were: 9mm of diameter ín the base (gingival); 8mm of height; cervical line in shoulder with one millimeter of width and 135 degrees of inclination; and tapered of 10 degrees. The capsules were excavated in the interior of other cylinders, with the tapered form, identical and negative in relation to the form of the dies. Forty-eight experimental conditions, in three rejoinders each, were made. The changeable were: internal relief in the capsules; and horizontal sulcus in the capsules and the dies. The relief varied between 2µm (in the condition without relief), 30µm and 60µm (in the conditions with relief). The sulcus varied between no sulcus and three sulcus, as much in the capsules as in the dies, with 200 µm depth, in equal amounts of specimens for each condition of sulcus. The capsules and dies were cemented. The experimental conditions were not repeated, except in the rejoinders. The specimens were submitted to traction test in universal test machine of Emic (ltaquaquecetuba-SP) in the Department of Materials and Technology of the College of Engineering of Guaratinguetá, UNESP. The data were submitted to statistic analysis for methods ANOVA and Tukey, showing significant dífference for the variable relief and sulcus in the capsules, and interacting individually and among then. They had not presented difference statistics for changeable the sulcus in the dies. The tensile strength increased with the relief and the amount of sulcus in the capsules, but it remained in the same level with the sulcus in the dies
234

Avaliação do uso de uma estrutura de nylon modificada como reforço de prótese totalmente acrílica implantossuportada

Gonçalves, Fernanda de Cássia Papaiz [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:15Z : No. of bitstreams: 1 000860671.pdf: 2218695 bytes, checksum: eb80ba359b0f6e3cf6bd8c9c2dcef065 (MD5) / O estudo avalou o comportamento de uma estrutura de nylon experimental com o propósito de ganho na resistência mecânica do material e ainda, na melhor distribuição de forças em toda extensão da prótese ao longo eixo dos implantes diminuindo o risco de fraturas e falhas neste sistema e, consequentemente maior longevidade. Para isso considerou-se próteses do tipo protocolo sem barra metálica, com e sem incorporação de reforço (nylon), variando a extensão da região do cantilever até primeiro molar/ segundo pré-molar (n=6). Os corpos de prova foram submetidos à análise de deformação por extensometria (extensometria s) e carga de 30 kg, e ao teste de carga máxima à fratura na EMIC (1000 kgf, 2 mm/min). Pode-se concluir que a incorporação da estrutura de reforço aumentou os valores de carga máxima independentemente da extensão do cantilever, além de apresentar menores valores de micro deformação ao redor de todos os implantes. As extensões de cantilever em pré-molar (5mm) além de apresentarem os menores valores de micro deformação quando comparadas a extensão em molar (15mm) também mostraram os maiores valores de carga máxima à fratura. / The study evaluated the behavior of a new compound of experimental nylon fiber, with the purpose of increasing the mechanical strength of the material and improving the strain distribution to the fullest extent of the prosthesis to the long axis of the implants reducing the risk of fractures and faults in the system and therefore increasing longevity. For this considered protocol type prostheses without metal bar, with and without incorporating reinforcement (nylon), varying the extent of the region of the cantilever to the first molar / second premolar (n = 6). The samples were subjected to analysis by extensometer strain (extensometria ) and load of 30 kg, and the maximum load test to fracture the EMIC (1000 kgf, 2 mm / min). It can be concluded that the incorporation of reinforcing mesh increased maximum load values regardless of the extent of the cantilever, and exhibit lower values microstrain around all implants. The cantilever extensions in premolar (5 mm) in addition of having the smallest microstrain values compared the extent to molar (15mm) also showed the highest maximum load values to fracture
235

Alterações do tecido mole, espaço faríngeo e estabilidade após avanço maxilo-mandibular xom rotação anti-horária e prótese total de ATM

Pizzol, Karina Eiras Dela Coleta [UNESP] 23 September 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-09-23Bitstream added on 2014-06-13T19:23:12Z : No. of bitstreams: 1 pizzol_kec_dr_arafo.pdf: 688008 bytes, checksum: 35e9164526c1e0e9be53fc6134f7ea9a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a resposta do tecido mole, do espaço faríngeo e a estabilidade após avanço maxilo-mandibular com rotação anti-horária e reconstrução da ATM com próteses totais articulares do tipo TMJ Concepts system®. As mudanças cirúrgicas e pós-cirúrgicas foram analisadas utilizando-se telerradiografias laterais. Com o movimento cirúrgico, houve redução do ângulo do plano oclusal (14,9 ± 8,0°) e aumento do espaço aéreo faríngeo - PASnar (4,9mm). A região anterior da maxila moveu-se para a frente e para cima enquanto a porção posterior, para a frente e para baixo. A mandíbula avançou, e sofreu rotação no sentido anti-horário. No período pós-cirúrgico, a maxila apresentou alterações mínimas no plano horizontal, enquanto todas as medidas mandibulares permaneceram estáveis. A postura da cabeça (OPT/NS) mostrou flexão imediatamente após a cirurgia e extensão em longo prazo, enquanto a curvatura cervical (OPT/CVT) não apresentou mudanças. Os resultados cirúrgicos mostraram ainda aumento das distâncias entre a terceira vértebra cervical (C3) e o mento e desta com o hióide, permanecendo estáveis durante o período de observação. A distância entre o osso hióide e o plano mandibular reduziu durante e após a cirurgia. Já a resposta do tecido mole evidenciou diferentes razões entre tecido duro/mole nos pacientes com e sem genioplastia. As mudanças horizontais na morfologia do lábio superior após avanço, impacção da maxila, sutura em VY e sutura da base alar mostraram maior movimento do que as mudanças observadas em tecido duro. O avanço maxilo-mandibular com rotação anti-horária do plano oclusal associado a próteses totais de ATM (TMJ Concepts system®) mostrou-se estável durante o período de observação. O espaço aéreo faríngeo aumentou... / This study evaluated stability, soft tissue response and oropharyngeal airway space changes after maxillo-mandibular advancement and counter-clockwise rotation with TMJ reconstruction using TMJ Concepts system® total joint prostheses. Lateral cephalograms were analyzed to estimate surgical and post surgical changes. During surgery, the occlusal plane angle decreased 14.9 ± 8.0° and the retroglossal airway space (PASnar) increased 4.9mm. The anterior region of maxilla moved forward and upward while the posterior nasal spine moved downward and forward. The mandible changed forward and rotated in a counter-clockwise direction. At long-term follow-up evaluation the maxilla showed minor horizontal changes, while all mandibular measurements remained stable. Head posture (OPT/NS) showed flexure immediately after surgery and extension long-term post surgery, while cervical curvature (OPT/CVT) had no significant changes. Surgery increased the distances between the third cervical vertebrae (C3) and menton, and C3 and hyoid, remaining stable afterwards. The distance from the hyoid to the mandibular plane decreased during surgery and in the longest follow-up. Soft tissue response indicated different hard/soft tissue ratios between patients with or without genioplasties. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement, than observed in hard tissue. TMJ Concepts total joint prostheses associated with maxillo-mandibular advancement and counter-clockwise rotation showed to be stable during the follow-up observation period. Immediate increase in oropharyngeal airway dimension, was influenced by post-surgical changes in head posture but remained stable over the follow-up period. Soft tissue changes showed a known predictable response.
236

Planejamento protético para pacientes adultos portadores de fissura labiopalatal congênita, que não obtiveram oportunidade de um tratamento reabilitador ideal: execução de casos clínicos para pacientes selecionados

Figueiredo, Aldari Raimundo [UNESP] 24 September 1992 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:24Z (GMT). No. of bitstreams: 0 Previous issue date: 1992-09-24Bitstream added on 2015-01-26T13:30:31Z : No. of bitstreams: 1 000024127.pdf: 3905448 bytes, checksum: 05963652393e1ca7e3f6c0c85b00a99b (MD5) / Embora não se possa prevenir o nascimento de indivíduos fissurados, podemos adotar atitudes e procedimentos vários, plenamente viáveis dentro de um complexo hospitalar-médico-odonto-psico-fono-pedagógico-social para tratamento, reabilitação e recuperação destas pessoas. Visando minorar o sofrimento destes pacientes, é que desenvolvemos este trabalho para provar que, senão de uma maneira “ideal”, mas bastante aceitável, podemos reintegrar estes indivíduos ao convívio de seus familiares e amigos, oferecendo-lhes mais segurança nos seus relacionamentos social, psíquico e humano. Fizemos um levantamento na literatura especializada nas últimas três décadas; encontramos inúmeras possibilidades de recuperação protética, no que concerne à estética, à mastigação e ao relacionamento maxilomandibular, além de permitir a esses pacientes condições de realizarem satisfatoriamente as funções da deglutinação e fala. Selecionamos e executamos cinco casos clínicos em uma mostragem de quinze pacientes previamente triados, procurando uma diversificação nos planejamentos protéticos. Mostramos ainda a enorme contribuição que os implantes osteointegrados podem oferecer na reabilitação e recuperação de pacientes com lesão labiopalatal congênita. Para facilitar o entendimento procuramos discutir os mais variados tipos de próteses em tópicos distintos, abordando cada uma delas isoladamente; mostrando que a especificidade de cada caso condiciona a uma conduta reabilitadora específica e individualizada, embasada em conceitos de estética, oclusão, suporte ósseo, espaço protético, retenção e, acima de tudo, do bom sendo e da honestidade profissional / Although one cannot prevent the birth of human beings with cleft palate lesions one can adopt attitudes and various procedures entirely viable to rehabilitate and recuperate these persons through a team work composed of the facilities of a hospital, physician, dentist, psychotherapist, epeech pathologist, pedagogue and a social worker. In order to reduce the suffering of these patients we took up this work to prove that even if not in an ideal manner nevertheleses in an acceptable one we can reintegrate these persons to their families, friends and social milieu, offering them more security in their social, psychic and human relationships. We have made a review of the literature during the last three decades where we found many possibilities of prosthetic recuperations which concerns esthetics, mastication and maxillomandibular relationships beyond allowing these pacients conditions to perform satisfactory the functions of deglution and speech. We have selected and executed 5 clinical cases out of 15 pacients formely choosen looking to different prosthetic plannings. We have also shown the major contribution that the osseous integrated implants can offer to the rehabilitation and recuperation of pacients whith congenitall labio palatal lesions. To simplify the understanding we tried to discuss the most varied types of prosthesis in well defined subjects having a separate approach for each of them and we still showed that the specificity of each case leads to a specific type of rehabilitation founded om esthetics, occlusion, osseous suport, edentulous space, and above all based in the common sense and Professional integrity
237

Estudo clínico de prevalência de sinais e sintomas de disfunções craniomandibulares e contatos oclusais cêntricos em pacientes portadores de lesão labiopalatal

Silva, Regina Célia Santos Pinto [UNESP] 24 September 1992 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:24Z (GMT). No. of bitstreams: 0 Previous issue date: 1992-09-24Bitstream added on 2015-01-26T13:30:31Z : No. of bitstreams: 1 000024656.pdf: 1495405 bytes, checksum: 564f831ac9396905debbc6230f9e3d95 (MD5) / Foi realizado um estudo em onze pacientes portadores de lesão labiopalatal, quanto a prevalência de sinais e sintomas de disfunções craniomandibulares, associada ao número e distribuição dos contatos oclusais cêntricos, através de questionário, exame clínico e exame dos modelos dos pacientes montados em articulador semi-ajustável, em posição de máxima intercuspidação. Com relação aos sinais e sintomas, os mais frequentes foram ruído articular e sensibilidade à palpação do músculo lateral, seguidos por limitação de abertura e sensação de cansaço. Quanto aos contatos oclusais, o número foi muito reduzido (cerca de 5 contatos por pacientes, em média) e a localização foi considerada atípica pois em 62% dos casos o contato ocorreu em plano inclinado, o que sugere instabilidade oclusal. Foi baixa a frequência dos sinais e sintomas encontrados e todos considerados suaves. Os três sinais mais comuns de disfunções craníomandibulares (ruído articular, sensibilidade muscular à palpação e limitação de abertura) estavam presentes em apenas um dos casos / A clinical investigation was undertaken to find out the prevalence of craniomandibular signs and symptoms in a group of 11 patients with labiopalatal lesions. The number and distribution of occlusal contacts was evaluated through questionnaire, clinical examination and analysis of mounted casts in partially adjustable articulators in the position of maximum inter cuspation. The most frequent signs and symptoms were articular sounds and lateral pterygoid muscle tenderness to palpation followed by restriction of mouth opening and sensation of tiredness. The number of occlusal contacts was small, mean of 5 contacts per patient, and the site was considered as atypical, 62% of them were on inclined plane surfaces , suggesting occlusal instability. The frequency of signs and symptoms was low and they were of a mild character. The most prevailing signs of craniomandibular dysfunction - articular sounds, muscular tenderness to palpation and restriction of mouth opening - was noticed in only one of the patients
238

Desenvolvimento de uma nova prótese para substituição de disco da coluna vertebral lombossacra através da metalurgia do pó

Souza, Alexandre Reus Baroni de January 2009 (has links)
O presente trabalho desenvolveu uma nova prótese para substituição de disco da coluna vertebral lombossacra, dividido em três macros etapas. Primeira etapa: conceito biomecânico e projeto assistido por computador (CAD/CAE), simulando estruturalmente o modelo virtual do implante. Segunda etapa: análise dos processos de fabricação, metalurgia do pó convencional (MPC) e por moldagem de pós por injeção (MIM), avaliando seus parâmetros. Terceira etapa: seleção do processo que mais se adaptou ao desenvolvimento de um implante, até a produção do protótipo de um implante. Foi utilizado pó comercialmente puro (99,5% Ti), com morfologia lamelar. A metalurgia do pó convencional (MPC) foi a selecionada para a fabricação do protótipo da nova prótese, compactada a 600 MPa e sinterizada a 1100°C durante 3h, neste patamar. O limite de elasticidade após a sinterização dos corpos de prova foi superior a 600 MPa, com densidade próxima a 4,04g/cm³. A porosidade foi avaliada por comparação volumétrica e imagens obtidas em MEV. Posteriormente foi analisada em software de processamento de imagens em diferentes regiões das amostras. A porosidade foi obtida por dois métodos: o primeiro considerou a imagem de uma superfície da amostra seguida pela variação da densidade em "bulk". O resultado da porosidade ficou entre 100µm e 500µm, faixa considerada adequada para a vascularização e crescimento ósseo. Foi aplicado uma carga de 3400N no modelo virtual do implante e a tensão resultante ficou abaixo de 60MPa. O resultado médio das densidades dos protótipos por Arquimedes do implante fabricados, foi de 4,05g/cm³. / The present study developed a new prosthesis to replace lumbosacral disks. It was divided in three steps. First step: biomechanical concept and computer assisted project (CAD/CAE), simulating the structure of the virtual model of the implant. Second step: analysis of manufacture process, conventional powder metallurgy (PM) and powder molding through injection, evaluating its parameters. Third step: selection of the process which best adapted to the development of an implant, up to the production of the implant prototype. Commercially pure powder (99,5% Ti) with lamellar morphology was used. Conventional powder metallurgy was selected to manufacture the new prosthesis, compacted at 600 MPa and sintered at 1100°C for 3 hours. The limit of elasticity after billets were sintered was above 700 MPa, and the density around 4,04g/cm³. Porosity was evaluated through images obtained in a SEM which were later analyzed by an image processing software in different parts of the billets. The result of porosity was between 100µm and 500µm, an adequate range for vascularization and bone growth. A charge of 3400N was applied to the virtual model of the implant and the resulting tension was under 60MPa. The resulting density in the manufactured prototypes was 4,05g/cm³, on average.
239

Design and Development of a Passive Prosthetic Ankle

January 2017 (has links)
abstract: In this work, different passive prosthetic ankles are studied. It is observed that complicated designs increase the cost of production, but simple designs have limited functionality. A new design for a passive prosthetic ankle is presented that is simple to manufacture while having superior functionality. This prosthetic ankle design has two springs: one mimicking Achilles tendon and the other mimicking Anterior-Tibialis tendon. The dynamics of the prosthetic ankle is discussed and simulated using Working model 2D. The simulation results are used to optimize the springs stiffness. Two experiments are conducted using the developed ankle to verify the simulation It is found that this novel ankle design is better than Solid Ankle Cushioned Heel (SACH) foot. The experimental data is used to find the tendon and muscle activation forces of the subject wearing the prosthesis using OpenSim. A conclusion is included along with suggested future work. / Dissertation/Thesis / Masters Thesis Mechanical Engineering 2017
240

Avaliação clínica e microbiológica da secreção conjuntival em usúarios de prótese ocular em resina acrílica

Neves, Ana Christina Claro [UNESP] 14 June 2000 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-06-14. Added 1 bitstream(s) on 2018-07-27T18:29:53Z : No. of bitstreams: 1 000127134.pdf: 1653433 bytes, checksum: a86ba2adfc63a2d23fea7089b1555de7 (MD5) / Este trabalho objetivou avaliar a microbiota bacteriana e fúngica das cavidades anoftálmicas, próteses oculares e olhos contralaterais de 43 usuários de prótese ocular em resina acrílica, unilateral, e relacionar a quantidade de secreção conjuntival presente nessas cavidades com a microbiota conjuntival, frequência de limpeza, tempo de uso e tempo decorrido desde o último polimento da prótese. Todos os pacientes apresentavam secreção conjuntival e microbiota Gram positiva nas cavidades anoftálmicas, Os microrganismos mais frequentemente isolados das 43 cavidades anoftálmicas, por ordem decrescente de freqüência, foram: Staphyfococcus coagulase negativos, Staphylococcus aureus, Candída albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Microbiota Gram negativa foi isolada de oito cavidades e fúngica, de três. O estudo estatístico dos dados evidenciou relação não significativa entre a quantidade de secreção conjuntival e a presença de microbiota Gram negativa• nas cavidades; e entre a quantidade de secreção conjuntival e a frequência de limpeza da prótese ocular. Correlação, estatisticamente significativa, foi constatada entre a quantidade de secreção conjuntiva! e o tempo de uso e o tempo decorrido desde o último polimento da prótese / The purpose of this work was to evaluate the bacterial and fungic microbiota of the anophthalmic sockets, ocular prosthesis and fellow eyes of forty three acrylic resin prosthesís carrying patients, and thereby relate the amount of conjunctival discharge to the presence of organisms, frequency of prosthesis cleaning, time of use and elapsed time since the last prosthesis polishing. All patients showed conjunctival discharge and Gram positive organisms in the anophthalmic sockets. The predominant organisms in the anophthalmic sockets were Staphylococcus coagulase negative, Staphylococcus aureus, Candida albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Gram negative bacteria were found in eight anophthalmic sockets and fungi in three. No relation was found between the amount of the conjunctival discharge and the presence of Gram negative bacteria in the anophthalmic socket, nor with the frequency of prosthesis cleaning. However, there was a significant relation between the amount of conjunctival discharge and time of prosthesis use, as well as time elapsed since the last prosthesis polishing

Page generated in 0.0659 seconds