• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 90
  • 29
  • 7
  • 1
  • Tagged with
  • 126
  • 48
  • 44
  • 31
  • 29
  • 29
  • 28
  • 25
  • 22
  • 18
  • 17
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

La survie implantaire suite à une réhabilitation par mise en charge immédiate d’une prothèse totale mandibulaire reliée à deux implants non jumelés : une étude pilote expérimentale

Audy, Nicholas 04 1900 (has links)
Problématique : Les connaissances théoriques et pratiques au sujet de la mise en charge immédiate d’implants non jumelés chez les édentés sont limitées. Objectifs : Cette étude avait pour but de : (1) déterminer le taux de survie implantaire de 2 implants non jumelés supportant une prothèse totale mandibulaire suite à une mise en charge immédiate, (2) évaluer les changements des niveaux osseux et de stabilité implantaire survenus sur ces 2 implants durant une période de 4 mois et les comparer à un implant témoin, et (3) décrire les complications cliniques associées à ce mode de mise en charge. Méthodologie : Chez 18 individus édentés (âge moyen de 62±7 ans), cette étude de phase I avec un design pré/post a évalué les résultats cliniques suivant la mise en charge immédiate (<48 heures) de 2 implants non jumelés par une prothèse totale mandibulaire. À l’aide de radiographies périapicales, de sondages osseux et d’analyses de la fréquence en résonnance, les niveaux osseux péri-implantaires (en mm) et les niveaux de stabilité implantairte (en ISQ) de ces 2 implants insérés dans la région parasymphysaire ont été évalués à la chirurgie (T0) et au suivi de 4 mois (T1). Un implant non submergé et sans mise en charge inséré dans la région de la symphyse mandibulaire a été utilisé comme témoin. Les données ont été analysées avec des modèles mixtes linéaires, la méthode de Tukey ajustée, l’analyse de variance de Friedman et des tests de rang signés de Wilcoxon. Résultats : De T0 à T1, 3 implants mis en charge immédiatement ont échoué chez 2 patients. Le taux de survie implantaire obtenu était donc de 91,7% (33/36) et, par patient, de 88,9% (16/18). Aucun implant témoin n’a échoué. Les changements osseux documentés radiologiquement et par sondage autour des implants mis en charge immédiatement étaient, respectivement, de -0,2 ± 0,3 mm et de -0,5 ± 0,6 mm. Les pertes d’os de support implantaire n’ont pas été démontrées statistiquement différentes entre les implants avec mise en charge immédiate et les témoins. Les niveaux moyens de stabilité implantaire ont augmenté de 5 ISQ indépendamment de la mise en charge. Les niveaux moyens d’ISQ n’ont pas été démontrés statistiquement différents entre les implants avec mise en charge immédiate et les témoins à T0 ou T1. Cinq des 18 patients n’ont expérimenté aucune complication clinique, alors que 9 en ont eu au moins deux. Hormis les échecs implantaires, aucune de ces complications n’a entraîné de changements au protocole. Conclusion : Les résultats à court terme suggèrent que : (1) le taux de survie implantaire suite au protocole immédiat est similaire à ceux rapportés lors d’un protocole de mise en charge conventionnel (2) les changements d’os de support implantaire et de stabilité ne sont pas différents comparativement à ceux d’un implant témoin, (3) un niveau élevé d’expérience clinique et chirurgicale est requis pour effectuer les procédures et pour gérer les complications associées. Ces résultats préliminaires devraient être confirmés dans une étude clinique de phase II. / Problem: There is a theoretical and practice knowledge gap in regard to immediate loading of unsplinted implants in edentulous individuals. Objectives: This study aimed to: (1) determine the implant survival rate of 2 unsplinted implants supporting a mandibular complete overdenture following an immediate loading protocol, (2) assess marginal bone level and implant stability changes of these immediately loaded implants in a 4-month period and compared them to a control implant, and (3) describe the clinical complications associated with this mode of loading. Methods: In 18 edentate individuals (mean age 62±7 years), this phase-I trial with a pre/post design assessed the clinical outcomes following the immediate loading (<48 hours) of 2 unsplinted implants supporting a mandibular overdenture. Periapical radiograhs, bone probing measurements and resonance frequency analysis were used to assess marginal bone losses and implant stability changes of these two implants inserted in the mandibular parasymphyseal region, at baseline (T0) and 4-month follow-up (T1). A non-submerged and non-loaded implant inserted in the mandibular symphysis was used as a control. Data were analyzed using linear mixed models, adjusted Tukey tests, Friedman’s analysis of variance and Wilcoxon signed-ranks tests. Results: From T0 to T1, 3 immediately loaded implants failed in 2 patients. This resulted in an implant survival rate of 91.7% (33/36), and, per patient, of 88.9% (16/18). No control implant failed. The marginal bone losses around loaded implants were -0.2 ± 0.3 mm for radiographic measurements and -0.5 ± 0.6 mm for probing measurements. There was no statistically significant difference between immediately loaded and control implants in regard to the supporting marginal bone losses. The implant stability levels increased of 5 ISQ units regardless of loading. There was no statistically significant difference in the mean ISQ levels between immediately loaded and control implants at T0 or T1. Five out of 18 patients experienced no clinical complication, while 9 of them had at least two. Apart from implant failures, none of these clinical complications led to changes in the protocol. Conclusion: The short-term results suggest that: (1) the implant survival rate following the immediate protocol is similar to those reported during a conventional loading protocol, (2) marginal implant supporting bone and stability changes are not different compared to those of a control implant, (3) a high level of clinical and surgical experience is required to perform the procedures and to manage the associated complications. These preliminary results should be confirmed in a phase II clinical trial.
92

Les attentes, la satisfaction et la qualité de vie des édentés suite à une réhabilitation par mise en charge immédiate d'une prothèse totale reliée à deux implants non jumelés : une étude pilote expérimentale

Menassa, Melanie 05 1900 (has links)
Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude. / Statement of problem: Most published research on the immediate loading of a mandibular 2-implant overdenture has only reported on clinical outcomes. Few studies have evaluated patients centered-outcomes but with measurement errors. Consequently, there is a need to assess clinical and patient-reported outcomes in this regard. Objectives: To examine patients’ level of satisfaction, expectations and quality of life with regard to the implants’ immediate loading protocol in edentate individuals. Methods: This phase-I trial used a pre-post design to assess patient-centered outcomes in 18 edentate individuals (mean age 62.39 ± 7.65 years) who have received a 2-implant (unsplinted) mandibular overdenture through an immediate loading protocol. The McGill Denture Satisfaction Instrument, a VAS instrument assessing expectations and the OHIP-20 questionnaire were used to evaluate patients’ outcomes at baseline, 2 weeks, 1 and 4 months. Socio-demographic and personality trait data were obtained using the Revised NEO Personality Inventory and a self-administered questionnaire. Change scores were calculated and non-parametrical tests were used to analyse the data. Repeated measures ANOVAs and paired t-tests were also conducted, and effect size was estimated. Results: The participants had a wide range of expectations regarding the immediate loading protocol. Expectations included short-term positive impact on aesthetics (83.3 %) and social life (55.7 %). Other expectations included negative effects on comfort (5.6%), the ability to chew (11.1 %) and to clean their lower denture (11.1%). At 4 months, the immediate loading protocol had met most patients’ expectations regarding aesthetics (94.4%), the ability to chew (83.3%), ability to speak (61.1%), comfort (94.4%), the ability to clean their lower denture (88.9%) and their social life (88.9%). The statistical analysis showed an overall satisfaction increase with a median change score of 66 (range=7-98), 68 (range=7- 95), and 70 (range= 17- 99), at 2 weeks, 1 month and 4 months respectively. There was a statistically significant improvement in overall satisfaction, comfort, perceived aesthetics, stability of the overdenture, and ability to chew at 2 weeks (p < 0,001). Pairwise comparison (within-subjects comparisons) revealed significant decreases in total OHIP scores (P < 0.001), as well as fewer functional limitations, physical pain, psychological discomfort, physical disability, psychological disability, and handicap (P < 0.01) from baseline to 2 weeks, 1 month and 4 months follow-up. Social disability score decrease significantly only after 1 month follow-up (p = 0.01). These changes remained stable during subsequent follow-ups. The protocol satisfied 94.4% of the participants and improve their quality of life with an estimated effect size of 1.9 (p < 0.001), regardless of socio-demographic and personality profiles. There was 100% agreement among patients on recommending this procedure to their peers. Conclusions: Immediate loading of two unsplinted implants with a mandibular overdenture seemed to fulfill patients’ satisfaction regardless of their expectations and may improve oral health-related quality life of edentate individuals in short-term. Encouraging results from phase I should be confirmed and approved in Phase II clinical trials.
93

Utilisation d'une décharge à barrière diélectrique pour développer une matrice polymère plasma dégradable pour des applications vasculaires / Using a dielectric barrier discharge to develop a degradable plasma polymer matrix for vascular applicationsg

Laurent, Morgane 03 November 2017 (has links)
Chaque année, environ 1,5 million de patients requièrent un remplacement vasculaire en réponse à une athérosclérose avancée, causant le rétrécissement interne des vaisseaux sanguins. Malheureusement, encore aujourd'hui les matériaux synthétiques utilisés pour remplacer les artères de petits diamètres (inférieurs à 6 mm) restent associés à un haut taux d'échecs, démontrant ainsi un manque de biocompatibilité certain. L'une des principales complications observées est l'hyperplasie néointimale artérielle caractérisée par l'obstruction du vaisseau sanguin due à la prolifération tridimensionnelle de cellules sur la paroi interne de la prothèse. Différentes stratégies visant à limiter cette réaction naturelle sont aujourd'hui envisagées, notamment l'utilisation d'un système à libération contrôlée de médicament intégré localement aux prothèses vasculaires. En parallèle, l'essor des technologies plasma a permis de montrer qu'il était possible de revêtir la surface de matériel biomédical pour améliorer son interaction avec un environnement biologique. La stratégie consiste à utiliser l'énergie et la réactivité d'un plasma pour polymériser un précurseur gazeux. En sélectionnant la structure moléculaire du précurseur et les conditions expérimentales du plasma appropriées, il est possible de déposer un polymère plasma à la surface du matériel sélectionné pour lui conférer des propriétés sur mesure. C'est dans ce contexte que cette thèse a consisté à synthétiser, à l'aide d'un plasma, une matrice polymère plasma biodégradable pour revêtir la paroi interne d'une prothèse vasculaire, dans le but d'y incorporer un médicament choisi de façon à limiter l'hyperplasie néointimale. Ce projet a permis d'une part de réaliser une preuve de concept en déposant un revêtement polymère plasma dégradable par décharge à barrière diélectrique en configuration planaire. En utilisant le lactate d'éthyle en tant que précurseur et après de nombreuses analyses, des conditions de dépôt optimales ont pu être élues pour leur potentiel dans le cadre d'applications vasculaires. D'autre part, grâce à une caractérisation approfondie de la décharge, une corrélation étroite entre la physico-chimie du plasma et les dépôts dégradables obtenus a pu être établie. Afin d'élargir les possibilités de vitesse de dégradation, l'influence d'une alimentation impulsionnelle sur la décharge et sur le dépôt a de plus été étudiée. Si la manière d'apporter l'énergie a eu une forte influence sur la décharge, aucune influence majeure n'a été notée sur la chimie et la morphologie des dépôts faits à partir de lactate d'éthyle. Enfin, la construction d'un réacteur plasma tubulaire permettant de déposer la matrice développée à l'intérieur de prothèses artérielles a permis de s'étendre aux conditions réelles de dépôt. Dans l'ensemble, ce projet de recherche a mis en évidence le potentiel des procédés plasma pour le développement de matrices polymères plasma dégradables, notamment dans le cadre de systèmes à libération contrôlée et locale de médicaments pour des applications en chirurgie vasculaire. D'un point de vue de la physique des plasmas, ce travail a de plus souligné l'importance de l'étude de la décharge dans de véritables conditions de dépôt de couches minces. / Every year, about 1.5 million patients need a vascular replacement due to advanced arteriosclerosis, which causes the internal narrowing of blood vessels. Unfortunately, even today the synthetic materials used to replace small diameter arteries (below 6 mm) remain associated with low patency rate, which demonstrates an evident lack of biocompatibility. One of the main observed complications is arterial neointimal hyperplasia, which is characterized by the blood vessel obstruction due to the tridimensional proliferation of cells on the graft internal wall. Different strategies aiming at limiting this body reaction are currently considered, in particular the use of a drug delivery system locally integrated to the vascular grafts. Concurrently, the rise of plasma technologies enabled to demonstrate the possibility to coat the surface of biomedical devices to improve their interaction with a biological environment. The strategy consists in using the plasma energy and reactivity to polymerize a gaseous precursor. By selecting the appropriate precursor molecular structure and plasma experimental conditions, one can build up a plasma polymer with tailored properties. It is in this context that this thesis consisted in synthesizing, using plasma, a biodegradable polymeric plasma polymer matrix to coat the internal wall of a vascular graft, with the goal to incorporate a drug chosen to limit neointimal hyperplasia. On one hand, this project acted as proof of concept by developing a degradable plasma polymer coating using a planar dielectric barrier discharge. After extensive studies using ethyl lactate as precursor, optimal chemical vapor deposition conditions were elected for their potential in terms of vascular applications. On the other hand, thanks to an extended discharge characterization, a strong correlation was established between the plasma physico-chemistry and the properties of the degradable coatings synthesized. In addition, to broaden possibilities in terms of degradation rate, the influence of a squared pulse power supply on the discharge and the coating was studied. If changing the way to bring the energy had a strong influence on the discharge, no major influence was noticed on the ethyl lactate-based coatings' chemistry and morphology. Finally, a tubular plasma reactor was build up to empower the internal wall of vascular prosthesis to be coated, which enabled to extend this project to the deposition conditions of its final application. Overall, this research project highlighted the potential of plasma processes for the development of degradable plasma polymer matrices, particularly for local drug delivery systems for vascular applications. On a physics perspective, this work emphasized the importance of studying the discharge under actual thin layer deposition conditions.
94

Within-subject comparison of two- versus three-implant-assisted mandibular overdenture : patient-based outcomes

Alesawy, Aminah 02 1900 (has links)
No description available.
95

Développement de nouveaux matériaux céramiques à base de zircone pour application dentaire / Development of new zirconia based ceramics for dental application

Courtois, Nicolas 06 December 2011 (has links)
Les céramiques polycristallines pour application dentaire sont aujourd’hui majoritairement des zircones dopées à l’yttrium (Y-TZP). Ce matériau présente des avantages indéniables en terme de résistance à la rupture, de propriétés esthétiques ou encore de ténacité grâce au phénomène de renforcement par transformation de phase. Les problèmes de stabilité de la Y-TZP en présence d’eau peuvent être limités par un travail d’optimisation des poudres, mais la sensibilité intrinsèque du matériau vis-à-vis de l’eau ou des fluides biologiques demeure et représente un risque, spécialement dans le cadre d’applications cliniques. Les matériaux à base de zircone dopée au cérium (Ce-TZP) présentés dans cette étude ont été développés afin de répondre au triple objectif de ténacité, résistance et stabilité. A partir de la Ce-TZP, connue pour sa ténacité et sa stabilité en présence d’eau importantes, un travail d’optimisation de la microstructure a été réalisé afin d’obtenir une résistance à la rupture maximale. Différentes voies ont été explorées afin d’élaborer des microstructures permettant une augmentation de la résistance mécanique de la Ce-TZP, notamment le frittage SPS ou l'élaboration de composites par mélange de poudres commerciales. Parmi les résultats présentés, le plus marquant est sans doute l’élaboration de composites dans le système 10Ce-TZP/MgAl2O4, caractérisés par une combinaison de propriétés mécaniques inédite (Sigma R = 900 MPa, KIc >15MPa.m1/2), et une stabilité à très long terme en présence d’eau . La mise en forme de ce matériau par des procédés industriels de pressage a été rendue possible grâce à une étape de granulation par atomisation ultrasonique. Enfin, un axe de recherche a été dédié à l’élaboration de poudres composites à base de Ce-TZP en une seule étape, par synthèse chimique. Ces travaux plus prospectifs montrent qu’un mélange très intime de deux phases peut-être obtenu par des méthodes de chimie douce dans une poudre composite. Ces poudres permettent l’élaboration de matériaux nanostructurés, dont les propriétés pourraient dépasser celles des composites conventionnels. / Yttria-doped tetragonal zirconia ceramics (often referred as Y-TZP) are today of major interest in biomedical and particularly dental applications, due to their excellent combination of strength and aesthetic features. Nevertheless, the moderate toughness of 3Y-TZP, and its still possible low temperature degradation (LTD) leaves space for new materials development. The purpose of this study is to assess the potential benefit of using ceria-doped zirconia (Ce-TZP) based ceramics as an tough, strong and stable alternative to Y-TZP. Ce-TZP generally possesses high toughness, but moderate strength when compared to 3Y-TZP, which is related to a larger grain size. In order to improve the strength of Ce-TZP, three microstructural optimizations have been carried out. First, Spark Plasma Sintering (SPS) has been used, showing a good potential for the development of nanostructured materials, which can be dense and mainly tetragonal, but aesthetically incompatible with a dental application. Cerium reduction effects on color and phase repartition have been studied. Adding a second step of conventional sintering in air has led to fully dense submicron 12Ce-TZP with acceptable color, but unsufficient strengthening. In a second step, a conventional composite approach has been used, by mixing commercial powders. The most striking result is certainly the uncommon combination of mechanical properties (Sigma R = 900 MPa, KIc > 15MPa.m1/2) obtained in the system 10Ce-TZP/MgAl2O4, together with a long term stability in presence of water. Pilot scale processing of this material has been set up by mean of ultrasonic spray-drying. Finally, a third research axis has been devoted to the synthesis of composite powders based on Ce-TZP, in one step. This work has shown that a very close mix of two phases can be obtained par soft chemistry methods in a composite powder. Nanostructured materials can be obtained from these powders, which properties could exceed those of conventional composites.
96

Nouvelles prothèses intervertébrales en composite céramique : Etude des matériaux, mise en place d'un test multiphysique in vitro et analyse de performances / New ceramic composite intervertebral prostheses : Materials study, set up of a new in vitro assessment and performance analysis

Preiss, Laura 04 May 2016 (has links)
Ce travail de thèse a porté sur de nouveaux implants intervertébraux en céramique. Au cours du projet dans son ensemble (projet européen Longlife), un nouveau matériau et de nouveaux designs d’implants ont été développés, ainsi qu’un nouveau test destiné à simuler les sollicitations subies in vivo par les implants afin d’estimer leur durée de vie. Le nouveau matériau développé est un composite triphasé composé d’une matrice de zircone dopée à l’oxyde de cérium (pour sa résistance au vieillissement), d’une phase globulaire d’alumine α (pour affiner la microstructure) et d’une phase allongée composée d’aluminates de strontium (pour augmenter la ténacité). La première partie du travail a consisté à caractériser ce matériau afin de connaître son comportement en termes de résistance mécanique, stabilité thermique, et de résistance à la stérilisation. Une deuxième partie a été consacrée au développement d’un test multiphysique regroupant les différentes sollicitations attendues par une prothèse in vivo (fatigue axiale, micro-séparation, vieillissement et usure). Il a fallu pour cela s’appuyer sur des simulations numériques qui ont permis de développer le système. Les données de la littérature ont été utilisées afin de choisir les paramètres du test (durée, fréquence, milieu d’essai). Enfin, la dernière partie de ce travail a été la mise à l’épreuve de différents prototypes à travers le test multiphysique et leur caractérisation en cours d’essai. Les principaux résultats de ce travail de thèse sont les suivants : le composite montre un comportement pseudo-plastique sous charge, avec une nette transformation de phase avant rupture, ce qui est positif dans le cadre de son utilisation. De plus, il ne semble pas affecté par la stérilisation. Du point de vue des implants développés, peu passent le test multiphysique. Le design, ainsi que la géométrie (notamment la clearance des échantillons) sont des leviers d’amélioration qui permettront d’augmenter la fiabilité des implants. / This work deals with the development of new intervertebral prostheses, made with ceramics. A whole European project, Longlife, was dedicated to the development of such implants. To achieve this goal, several axes have been followed: the synthesis of a new material, the development of new designs of intervertebral bodies, and the set-up of a new test aimed at reproducing in vitro the different solicitations undergone by an intervertebral implant in vivo. The new material developed is a triphasic composite composed of a matrix of ceria-doped zirconia (insensitive to ageing), a secondary globular phase of α-alumina (to reduce the grain size), and a third, elongated phase composed of strontium aluminates platelets (in order to improve fracture toughness). The first part of this work was to characterize this new material in order to forecast its behaviour under mechanical solicitation, thermal stability and resistance to sterilization. Secondly, the set-up of the new test is exposed. Different steps were chosen (axial fatigue, micro-separation, ageing and wear) in order to reproduce the “real-life” solicitations. To achieve this goal, Finite Elements simulations were performed, allowing the development of specific specimen holders that mimic the fixation of the implants in the vertebrae. The parameters of the test (duration, frequency, medium) were chosen after a details survey of the literature and of standards. At the end, we tested different prototypes trough this new multiphysic assessment set up. As a main result of this thesis, the chosen ceramic composite exhibits a pseudo-plastic behaviour, with a large deformation due to phase transformation before fracture, which is a positive result in the framework of the forecast applications. Moreover, the material doesn’t seem degraded by the sterilization processes. Concerning the multiphysic test, only a few implants resisted it. The design of the implants is a key-point, as well as the geometry (in particular, clearance seems to be critical).
97

La survie implantaire suite à une réhabilitation par mise en charge immédiate d’une prothèse totale mandibulaire reliée à deux implants non jumelés : une étude pilote expérimentale

Audy, Nicholas 04 1900 (has links)
Problématique : Les connaissances théoriques et pratiques au sujet de la mise en charge immédiate d’implants non jumelés chez les édentés sont limitées. Objectifs : Cette étude avait pour but de : (1) déterminer le taux de survie implantaire de 2 implants non jumelés supportant une prothèse totale mandibulaire suite à une mise en charge immédiate, (2) évaluer les changements des niveaux osseux et de stabilité implantaire survenus sur ces 2 implants durant une période de 4 mois et les comparer à un implant témoin, et (3) décrire les complications cliniques associées à ce mode de mise en charge. Méthodologie : Chez 18 individus édentés (âge moyen de 62±7 ans), cette étude de phase I avec un design pré/post a évalué les résultats cliniques suivant la mise en charge immédiate (<48 heures) de 2 implants non jumelés par une prothèse totale mandibulaire. À l’aide de radiographies périapicales, de sondages osseux et d’analyses de la fréquence en résonnance, les niveaux osseux péri-implantaires (en mm) et les niveaux de stabilité implantairte (en ISQ) de ces 2 implants insérés dans la région parasymphysaire ont été évalués à la chirurgie (T0) et au suivi de 4 mois (T1). Un implant non submergé et sans mise en charge inséré dans la région de la symphyse mandibulaire a été utilisé comme témoin. Les données ont été analysées avec des modèles mixtes linéaires, la méthode de Tukey ajustée, l’analyse de variance de Friedman et des tests de rang signés de Wilcoxon. Résultats : De T0 à T1, 3 implants mis en charge immédiatement ont échoué chez 2 patients. Le taux de survie implantaire obtenu était donc de 91,7% (33/36) et, par patient, de 88,9% (16/18). Aucun implant témoin n’a échoué. Les changements osseux documentés radiologiquement et par sondage autour des implants mis en charge immédiatement étaient, respectivement, de -0,2 ± 0,3 mm et de -0,5 ± 0,6 mm. Les pertes d’os de support implantaire n’ont pas été démontrées statistiquement différentes entre les implants avec mise en charge immédiate et les témoins. Les niveaux moyens de stabilité implantaire ont augmenté de 5 ISQ indépendamment de la mise en charge. Les niveaux moyens d’ISQ n’ont pas été démontrés statistiquement différents entre les implants avec mise en charge immédiate et les témoins à T0 ou T1. Cinq des 18 patients n’ont expérimenté aucune complication clinique, alors que 9 en ont eu au moins deux. Hormis les échecs implantaires, aucune de ces complications n’a entraîné de changements au protocole. Conclusion : Les résultats à court terme suggèrent que : (1) le taux de survie implantaire suite au protocole immédiat est similaire à ceux rapportés lors d’un protocole de mise en charge conventionnel (2) les changements d’os de support implantaire et de stabilité ne sont pas différents comparativement à ceux d’un implant témoin, (3) un niveau élevé d’expérience clinique et chirurgicale est requis pour effectuer les procédures et pour gérer les complications associées. Ces résultats préliminaires devraient être confirmés dans une étude clinique de phase II. / Problem: There is a theoretical and practice knowledge gap in regard to immediate loading of unsplinted implants in edentulous individuals. Objectives: This study aimed to: (1) determine the implant survival rate of 2 unsplinted implants supporting a mandibular complete overdenture following an immediate loading protocol, (2) assess marginal bone level and implant stability changes of these immediately loaded implants in a 4-month period and compared them to a control implant, and (3) describe the clinical complications associated with this mode of loading. Methods: In 18 edentate individuals (mean age 62±7 years), this phase-I trial with a pre/post design assessed the clinical outcomes following the immediate loading (<48 hours) of 2 unsplinted implants supporting a mandibular overdenture. Periapical radiograhs, bone probing measurements and resonance frequency analysis were used to assess marginal bone losses and implant stability changes of these two implants inserted in the mandibular parasymphyseal region, at baseline (T0) and 4-month follow-up (T1). A non-submerged and non-loaded implant inserted in the mandibular symphysis was used as a control. Data were analyzed using linear mixed models, adjusted Tukey tests, Friedman’s analysis of variance and Wilcoxon signed-ranks tests. Results: From T0 to T1, 3 immediately loaded implants failed in 2 patients. This resulted in an implant survival rate of 91.7% (33/36), and, per patient, of 88.9% (16/18). No control implant failed. The marginal bone losses around loaded implants were -0.2 ± 0.3 mm for radiographic measurements and -0.5 ± 0.6 mm for probing measurements. There was no statistically significant difference between immediately loaded and control implants in regard to the supporting marginal bone losses. The implant stability levels increased of 5 ISQ units regardless of loading. There was no statistically significant difference in the mean ISQ levels between immediately loaded and control implants at T0 or T1. Five out of 18 patients experienced no clinical complication, while 9 of them had at least two. Apart from implant failures, none of these clinical complications led to changes in the protocol. Conclusion: The short-term results suggest that: (1) the implant survival rate following the immediate protocol is similar to those reported during a conventional loading protocol, (2) marginal implant supporting bone and stability changes are not different compared to those of a control implant, (3) a high level of clinical and surgical experience is required to perform the procedures and to manage the associated complications. These preliminary results should be confirmed in a phase II clinical trial.
98

Les attentes, la satisfaction et la qualité de vie des édentés suite à une réhabilitation par mise en charge immédiate d'une prothèse totale reliée à deux implants non jumelés : une étude pilote expérimentale

Menassa, Melanie 05 1900 (has links)
Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude. / Statement of problem: Most published research on the immediate loading of a mandibular 2-implant overdenture has only reported on clinical outcomes. Few studies have evaluated patients centered-outcomes but with measurement errors. Consequently, there is a need to assess clinical and patient-reported outcomes in this regard. Objectives: To examine patients’ level of satisfaction, expectations and quality of life with regard to the implants’ immediate loading protocol in edentate individuals. Methods: This phase-I trial used a pre-post design to assess patient-centered outcomes in 18 edentate individuals (mean age 62.39 ± 7.65 years) who have received a 2-implant (unsplinted) mandibular overdenture through an immediate loading protocol. The McGill Denture Satisfaction Instrument, a VAS instrument assessing expectations and the OHIP-20 questionnaire were used to evaluate patients’ outcomes at baseline, 2 weeks, 1 and 4 months. Socio-demographic and personality trait data were obtained using the Revised NEO Personality Inventory and a self-administered questionnaire. Change scores were calculated and non-parametrical tests were used to analyse the data. Repeated measures ANOVAs and paired t-tests were also conducted, and effect size was estimated. Results: The participants had a wide range of expectations regarding the immediate loading protocol. Expectations included short-term positive impact on aesthetics (83.3 %) and social life (55.7 %). Other expectations included negative effects on comfort (5.6%), the ability to chew (11.1 %) and to clean their lower denture (11.1%). At 4 months, the immediate loading protocol had met most patients’ expectations regarding aesthetics (94.4%), the ability to chew (83.3%), ability to speak (61.1%), comfort (94.4%), the ability to clean their lower denture (88.9%) and their social life (88.9%). The statistical analysis showed an overall satisfaction increase with a median change score of 66 (range=7-98), 68 (range=7- 95), and 70 (range= 17- 99), at 2 weeks, 1 month and 4 months respectively. There was a statistically significant improvement in overall satisfaction, comfort, perceived aesthetics, stability of the overdenture, and ability to chew at 2 weeks (p < 0,001). Pairwise comparison (within-subjects comparisons) revealed significant decreases in total OHIP scores (P < 0.001), as well as fewer functional limitations, physical pain, psychological discomfort, physical disability, psychological disability, and handicap (P < 0.01) from baseline to 2 weeks, 1 month and 4 months follow-up. Social disability score decrease significantly only after 1 month follow-up (p = 0.01). These changes remained stable during subsequent follow-ups. The protocol satisfied 94.4% of the participants and improve their quality of life with an estimated effect size of 1.9 (p < 0.001), regardless of socio-demographic and personality profiles. There was 100% agreement among patients on recommending this procedure to their peers. Conclusions: Immediate loading of two unsplinted implants with a mandibular overdenture seemed to fulfill patients’ satisfaction regardless of their expectations and may improve oral health-related quality life of edentate individuals in short-term. Encouraging results from phase I should be confirmed and approved in Phase II clinical trials.
99

A randomized follow-up study of the general health and quality of life of an elderly edentulous population wearing either mandibular two-implant overdentures or conventional dentures

Emami, Elham 12 1900 (has links)
L’augmentation de la population âgée dans la société indique que les systèmes de soins de la santé font face à de nouveaux défis. Les hauts niveaux d’incapacité qui en résultent peuvent être réduits par les nouvelles technologies, la promotion de la santé ainsi que des stratégies de prévention. Les écrits scientifiques récents soulignent la supériorité des prothèses dentaires implanto-portées par rapport aux prothèses conventionnelles en termes de satisfaction et de qualité de la vie des patients. Cependant, il n'est toujours pas clair si ces avantages ont des effets positifs à long terme sur la santé orale et générale ainsi que sur la qualité de vie des populations âgées. Objectifs, Hypothèses : Notre but était de mesurer l’impact des prothèses mandibulaires retenues par 2 implants sur la qualité de vie associée à la santé bucco-dentaire et générale ainsi que sur la santé orale et la qualité du sommeil des aînés édentés. Nous avons évalué les hypothèses nulles suivantes : il n'y a aucune différence entre les individus portants des prothèses mandibulaires retenues par 2 implants (IODs) et ceux qui portent des prothèses conventionnelles (CDs), par rapport à la qualité de vie reliée à la santé bucco-dentaire et générale, la santé orale et la qualité du sommeil, un an après avoir reçu leurs nouvelles prothèses. Méthodes : Dans cette étude randomisée contrôlée, 255 aînés ont reçu au hasard IODs ou les CDs, les deux types de prothèses étant opposés à des prothèses maxillaires conventionnelles. La qualité de la vie reliée à la santé bucco-dentaire (OHRQoL) et la santé générale subjective ont été mesurées avec les questionnaires Oral Health Impact Profile (OHIP-20) et Short Form-36 (SF-36) en condition pré-traitement et après un an. La qualité du sommeil et la somnolence diurne ont été mesurées à l’aide du questionnaire Qualité de Sommeil de Pittsburg et de l'Échelle de Somnolence Epworth. La santé orale a été évaluée par un examen clinique. Les variables indépendantes étaient le sens de cohérence et le type de prosthèse, ainsi que des variables socio-démographiques. En utilisant des analyses statistiques bi et multi-factorielles, des comparaisons à l’intérieur d’un même groupe et entre deux groupes ont été effectuées. Résultats : Les différences pré et post traitement pour les cotes OHIP étaient significativement plus grandes pour le groupe IOD que le groupe CD (p<0.05). Le type de traitement et la cote pré-traitement étaient des facteurs significatifs à OHRQoL (p < 0.0001). Dans le groupe CD, il y avait une diminution significative par rapport aux cotes de «Physical Component Scores (PCS)», le fonctionnement physique, le rôle physique et la douleur physique entre les données pré-traitement et un an après le traitement, ce qui indique une diminution au niveau de la santé générale subjective. Dans le groupe IOD, une diminution statistiquement non significative a été remarquée par rapport à toutes les cotes des sous-échelles de SF-36, sauf pour la douleur physique. Le modèle final de régression a démontré qu’après ajustement pour les variables âge, sexe, statut marital et type de traitement, la cote totale finale d’OHIP et les données de bases de PCS prédisaient la cote finale de PCS (p < 0.0001). Aucune corrélation significative entre sens de cohérence et OHRQoL n'a été détectée (r =-0.1; p > 0.05). Les aînés porteurs des prothèses conventionnelles avaient presque 5 fois plus de chance d’avoir une stomatite prothétique que ceux portant des prothèses mandibulaires hybrides retenues par 2 implants (p < 0.0001). Les aînés ayant subjectivement une mauvaise santé générale avaient une qualité de sommeil moins bonne que ceux avec une meilleure santé générale subjective (p < 0.05). Les personnes qui avaient une OHRQoL moins bonne étaient presque 4 fois plus somnolentes pendant le jour que celles avec une meilleure OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). L'analyse de régression a montré que la santé générale subjective et OHRQoL prévoient la qualité du sommeil (p=0.022 et p=0.001, respectivement) et la somnolence diurne (p=0.017 et p=0.005, respectivement). Conclusions: Les résultats de cette étude suggèrent que, chez les aînés édentés, des prothèses mandibulaires hybrides retenues par deux implants amènent une amélioration significative de la qualité de vie reliée à la santé bucco-dentaire et maintiennent la sensation d’une meilleure santé physique. Des prothèses hybrides implanto-portées peuvent contribuer à la santé orale en réduisant les traumatismes infligés à la muqueuse orale et en contrôlant la stomatite prothétique. Les aînés édentés dont le niveau de qualité de vie reliée à la santé bucco-dentaire est bas, peuvent aussi avoir des troubles de qualité du sommeil. / The global greying of society indicates that health care systems face new challenges. High levels of disability can be reduced through new technologies, health promotion and preventive strategies. Recent literature has underlined the superiority of mandibular implant overdentures over conventional dentures for patient satisfaction and quality of life. However, it is still not clear whether this benefit has any long-term positive effects on oral and general health, as well as on the quality of life of elderly populations. Objectives, Hypotheses: We aimed to measure the impact of mandibular two-implant overdentures on the general and oral health quality of life, as well as on oral health and sleep quality of edentulous elders. We tested the null hypothesis that there is no difference in the general and oral health quality of life, as well as, on oral health and sleep quality of those wearing mandibular two-implant overdentures (IODs) and those who wear conventional dentures (CDs), one year following prosthesis delivery. Methods: In this randomized controlled trial, 255 elders randomly received IODs or CDs, both opposed by conventional maxillary dentures. OHRQoL and perceived general health were measured with the Oral Health Impact Profile (OHIP-20) and the Short Form-36 (SF-36) at baseline and after one year. Sleep quality and daytime sleepiness were measured with the Pittsburg Sleep Quality global score and the Epworth Sleepiness Scale. Clinical exams were conducted to evaluate oral health. Independent variables included sense of coherence and prosthesis type, as well as socio-demographic variables. Between and within group comparisons were performed using bivariate and multivariate statistical tests. Results: Pre/post treatment differences in OHIP scores were significantly greater for the IOD than the CD group (p<0.05). Type of treatment and pre-treatment scores were significant contributors to OHRQoL (p<0.0001). In the CD group, there was a statistically significant decrease in physical component scores (PCS), physical functioning, role physical and bodily pain from baseline to one year follow up, indicating decreased perceived general health. In the IOD group, no statistically significant decrease was seen in SF-36 subscale scores from baseline to one year, except for bodily pain. The final regression model demonstrated that, after controlling for age, sex, marital status and type of treatment, the OHIP total final and the PCS baseline scores predict PCS final scores (p<0.0001). No significant correlation between sense of coherence and OHRQoL was detected (r= -0.1; p> 0.05). Elders wearing conventional dentures were almost 5 times more likely to have denture stomatitis than those wearing mandibular two-implant retained overdentures (p < 0.0001). Elders with low perceived general health had poorer sleep than those with high perceived general health (p<0.05). Those with low oral health related quality of life were almost 4 times sleepier during the day than those with high OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). Regression analysis showed that perceived general health and OHRQoL predict sleep quality (p=0.022 and p=0.001, respectively) and daytime sleepiness (p=0.017 and p=0.005, respectively). Conclusions: The results of this study suggest that, in edentulous elders, mandibular two-implant overdentures provide significant improvement in oral health related quality of life and maintain perceived physical health. Implant overdentures may contribute to oral health by reducing oral mucosa trauma and control denture stomatitis. Edentulous elders whose oral health related quality of life is low may also have poor sleep quality.
100

A randomized controlled trial evaluating the quality of life and the sense of coherence in seniors wearing complete conventional dentures or mandibular two-implant overdentures

Jabbour, Zaher 12 1900 (has links)
La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs. / ABSTRACT The superiority and stability of the effect of mandibular two-implant retained overdentures (IODs) over conventional dentures (CDs) in relation to the oral health-related quality of life (OHRQoL) remain to be clarified. Furthermore, the influence of psychological factors, such as the sense of coherence (SOC), on the perception of treatment outcomes is still unknown. The aim of this study was to determine the magnitude of the effect of IODs and CDs on the OHRQoL and assess the stability of the treatment over time taking into account the level of SOC. METHODOLOGY: Edentulous participants (n = 172, mean age 71, SD = 4.5) wearing CDs or IODs were followed up for two years. The OHRQoL was assessed at baseline and both follow-ups using the « Oral Health Impact Profile (OHIP-20) » questionnaire. The SOC was only assessed at both follow-ups using « The Orientation to Life (SOC-13) » questionnaire. Statistical analyses were conducted to evaluate between and within treatment differences (descriptive, bivariate and multivariate statistical analyses). RESULTS: A significant pre-/post-treatment improvement in the OHRQoL for both treatment groups was found (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). The magnitude of the effect in the IOD group was 1.5 times larger than that in the CD group. These outcomes were stable over the two-year study period and the SOC did not influence any of these results. CONCLUSION: IODs provide better long-term OHRQoL than CDs regardless of SOC level. The results are clinically meaningful and confirm the superiority of IODs over CDs.

Page generated in 0.0728 seconds