Imagerie multiphotonique de la sérotonine par contraste endogène : vers un outil pour évaluer la concentration de la sérotonine in vivo

Samson, Karen 18 April 2018 (has links)
La sérotonine (5-HT) est un neurotransmetteur régulant plusieurs fonctions fondamentales du corps : la thermorégulation, le comportement sexuel et alimentaire, le cycle éveil-sommeil, la perception de la douleur, l'anxiété, le contrôle moteur, mais elle est surtout connue pour le contrôle de l'humeur. Le manque de sérotonine dans le système nerveux central est associé aux maladies mentales. Ces maladies sont la dépression, le trouble bipolaire, l’anxiété, le trouble de panique, les phobies, les troubles obsessionnel-compulsifs et la schizophrénie. Un outil pour la détection de la sérotonine et de ses précurseurs nous permettrait d'étudier les mécanismes des diverses maladies impliquant un débalancement de la sérotonine. Dans le système nerveux central, la biosynthèse de la sérotonine se fait dans certains neurones du tronc cérébral. La sérotonine, tout comme son précurseur le tryptophane (Trp), est fortement fluorescente en comparaison à d'autres molécules endogènes. L’imagerie multiphotonique a été exploitée dans le cadre de ce projet pour détecter la sérotonine. Cette technique d’imagerie permet d’obtenir une bonne spécificité et d’offrir un sectionnement optique pour l’imagerie dans les cellules et les tissus. Différents processus d’excitation (à 2- et 3- photons) dans différentes conditions (cellules fixées ou non) ont été explorés afin d’optimiser la détection de l’autofluorescence de la sérotonine. Nous avons donc d’abord développé un système d’imagerie capable de détecter la fluorescence des molécules de la biosynthèse de la sérotonine, excluant le tryptophane. Nous sommes capables de détecter ces espèces isolées à des concentrations avoisinant le milli molaire en solutions. La méthode a été testée dans deux modèles contenant de la sérotonine (cellules et tranches). Les mesures ont démontré un manque de spécificité et sensibilité lorsqu’utilisées dans des systèmes plus complexes que les simples solutions. Ce manque de spécificité et de sensibilité est discuté avec des pistes d’amélioration pour les projets futurs, incluant l’utilisation d’autres modèles mieux contrôlés et d’autres techniques optiques plus avancées. / Serotonin (5-HT) is a neurotransmitter regulating several basic functions of the body: thermoregulation, sexual and food behavior, the sleep-wake cycle, perception of pain, anxiety, motor control, but is best known for control of mood. The lack of serotonin in the central nervous system is associated with mental illness. These diseases are depression, bipolar disorder, anxiety, panic disorder, phobias, obsessive-compulsive disorder and schizophrenia. A detection tool of serotonin and its precursors would allow us to study the mechanism of various diseases involving an imbalance of this neurotransmitter. In the central nervous system, the biosynthesis of serotonin occurs in specific neurons of the brainstem. Serotonin, like its precursor tryptophan (Trp), is highly fluorescent in comparison to other endogenous molecules. Multiphoton fluorescence excitation has been used in this project to detect serotonin without exogenous labels. This fluorescence imaging technique provides a good specificity as well as optical sectioning for imaging in cells and tissues. Different excitation processes (two- and three-photon) under different conditions (fixed cells or not) were explored to optimize the detection of autofluorescence of serotonin. We therefore first developed an imaging system capable of detecting the fluorescence of molecules involved in the biosynthesis of serotonin, excluding tryptophan. We are able to detect these isolated species in solution at concentrations near a millimolar. The method was tested in two models containing serotonin (cells and slices). The measurements have shown a lack of specificity and sensitivity when used in systems more complex than simple solutions. This lack of specificity and sensitivity is discussed with possible improvements for future project including the use of other models with better control of serotonin concentrations, of other more advanced optical techniques such as fluorescence lifetime imaging.
12

Multi-skyrmions quasi-BPS et noyaux atomiques : énergie de Coulomb et configurations pleines

Harbour, Louis 19 April 2018 (has links)
Le modèle de Skyrme est une théorie des champs classique non-linéaire qui possède des solitons topologiques comme solutions. De façon innovatrice, ces solutions sont utilisées par Skyrme pour décrire les baryons. Ceci est justifié puisque le modèle est une théorie efficace de la chromodynamique quantique à basse énergie et puisque les solutions possèdent un nombre topologique conservé qu'on associe au nombre baryonique. Le modèle original permet de décrire les propriétés des nucléons avec une précision de 30% ou mieux, mais a de la difficulté à reproduire les caractéristiques des baryons de masse élevé. En effet, l'énergie de liaison des multi-skyrmions est très grande et les densités baryonique possèdent des structures spatiales complexes et de type coquille ce qui s'éloignent des observations expérimentales. On propose alors une extension du modèle afin d'améliorer précisément les deux problèmes précédents. Ce travail introduit le modèle de Skyrme quasi-BPS dont les solutions analytiques saturent presque la borne de Bogomol'nyi améliorant les prédictions de l'énergie de liaison des multi-skyrmions. Le choix d'un potentiel permettant d'obtenir des densités baryonique de configurations pleines et l'ajout de l'énergie de Coulomb et de brisure de symétrie d'isospin à la masse du skyrmion sont les contributions originales de ce travail. Ceci permet d'obtenir des meilleurs prédictions physiques pour les multi-skyrmions de nombre baryonique très élevé que dans le modèle original et l'analyticité des solutions en simplifie le traitement. Pour ces raisons, le modèle de Skyrme quasi-BPS s'avère une bonne théorie efficace pour la descriptions des noyaux atomiques.
13

Applications de résonateurs Fabry-Pérot pour l'imagerie par super-lentilles et pour les réseaux de Bragg à sauts de phase divisés

Tremblay, Guillaume 18 April 2018 (has links)
Le présent travail est divisé en deux sections, chacune étant consacrée à une application particulière des structures de Fabry-Perot dans un domaine spécifique de l'optique moderne. La Section I traite du design de structures d'imagerie par superlentilles, qui servent essentiellement à la génération d'images de champ proche de structures dont les caractères sont plus petits que la demi-longueur d'onde, en utilisant des approches originales et performantes. Ces structures sont constituées de couches de matériaux très minces, dont l'épaisseur est de l'ordre de la dizaine de nanometres, et dont les interfaces font office de miroirs à réflectivité complexe de telle sorte qu'on peut les associer à une cascade de cavités Fabry-Perot. La théorie fondamentale des structures de super-lentilles, qu'elles soient constituées du cas idéal utilisant une couche de matériau d'indice négatif ou de métal, est exposée. Une méthode de design basée sur une étude modale de la super-lentille métallique ainsi qu'une approche de design numérique de super-lentille basée sur un modèle raffiné de la super-lentille qui inclut l'objet à imager sont ensuite proposées. Dans les deux cas, les designs obtenus se comparent avantageusement avec d'autres présentés dans la littérature. La Section II étudie le problème de la division de sauts de phase dans les réseaux de Bragg écrits à l'aide d'un masque de phase dans lequel les sauts de phase sont inscrits. Dans les réseaux comprenant un seul saut de phase de à mi-longueur qu'on appelle filtres Fabry-Perot (FP) basés sur réseaux, la division en deux du saut de phase se manifeste physiquement par l'écriture d'une section de réseau très petite entre chacun des deux demi-sauts de phase causant des erreurs d'asymétrie dans sa réponse spectrale. On modélise les filtres FP à saut de phase divisé comme une succession de trois miroirs à réflectivité complexe variant avec la longueur d'onde séparés par les deux demi-sauts de phase. On constate que pour des filtres FP longs de plus de quelques millimètres, l'effet de la division d'un saut de phase est négligeable.
14

Utilisation d'axicons pour la microscopie à deux photons

Dufour, Pascal 19 April 2018 (has links)
Un des enjeux majeurs de la biochimie et de la biologie cellulaire actuelle est de pouvoir suivre de manière dynamique les événements moléculaires à l'intérieur de la cellule vivante dans son contexte fonctionnel, c'est-à-dire in situ (dans son tissu d'origine). Il ne suffit plus, par exemple, d'identifier une réaction biochimique in vitro pour pouvoir savoir si un enzyme ou un autre rencontrera son substrat à l'intérieur de la cellule. Il apparaît de plus en plus évident que des facteurs spatio-temporels très fins à l'intérieur de la cellule vivante déterminent en grande partie la spécificité des signaux cellulaires. Il suffit de penser aux fluctuations calciques intracellulaires, par exemple, qui participent à une multitude de cascades de signalisation; sans spécificité spatiale et temporelle, la cellule ne pourrait utiliser les signaux calciques de manière utile et efficace. A cette fin, on propose un système de microscopie laser qui incorpore un axicon, lequel a la propriété de focaliser la lumière en un faisceau quasi-Bessel. Le contrôle du profil du faisceau incident sur l'axicon procure une ligne focale sur l'axe longitudinal ayant une intensité constante dans le milieu absorbant ainsi qu'une grande résolution transverse. Conséquemment, nous devons balayer notre échantillon en deux dimensions seulement pour obtenir une image complète de tout le volume, réduisant ainsi considérablement le temps d'acquisition. Nous présenterons les résultats théoriques de la génération d'un faisceau quasi-Bessel dans un échantillon absorbant, les caractéristiques du laser Ti:saphir utilisé ainsi que le schéma proposé pour la microscopie laser avec un axicon. Nous verrons qu'il est possible d'imager des échantillons fluorescents allant jusqu'à 1 mm d'épaisseur avec un seul balayage. Dans cette thèse, nous passerons en revue quelques principes qui sont à la base des avantages de la microscopie par excitation à deux photons afin de mettre en relief certains des défis (résolution spatiale, résolution temporelle, sensibilité, profondeur de pénétration dans le tissu et phototoxicité) pour améliorer l'utilisation de cette approche pour l'imagerie cellulaire fonctionnelle. Les propriétés des faisceaux de Bessel formés par l'axicon seront étudiées en profondeur. Nous décrirons ensuite notre microscope à deux photons avec un axicon et nous présenterons plusieurs résultats obtenus avec ce dernier.
15

Développement de nouveaux dosimètres à scintillateurs plastiques pour des applications in vivo en radiothérapie et curiethérapie à haut débit de dose

Therriault-Proulx, François 19 April 2018 (has links)
Le but de cette thèse est de développer de nouveaux systèmes de dosimétrie par scintillateurs plastiques afin de faciliter leur implémentation comme détecteurs de dose in vivo en temps réel pour la radiothérapie et surtout pour la curiethérapie à haut débit de dose. Dans un premier temps, la nécessité de soustraire la lumière induite dans le guide optique par effet de tige a été démontrée pour cette modalité d'irradiation. Le détecteur développé pour cette étude a ensuite été utilisé afin de démontrer sa capacité à effectuer des mesures de dose en temps réel lors de la délivrance d'un traitement de curiethérapie de prostate à haut débit de dose à l'intérieur d'un fantôme d'eau. La dose déposée à chaque position de source, dans chaque cathéter et pour la fraction entière était comparable à la dose attendue par le système de planification de traitement. Comme les dosimètres à scintillation jusqu’à ce jour nécessitent une fibre optique de transmission par scintillateur, la preuve de faisabilité pour la mesure adéquate de doses de radiation avec un détecteur multi-points utilisant une seule fibre de transmission a été effectuée. Cela a d’abord été effectué pour des détecteurs à 2 et 3 points de mesure exposés à des irradiations externes de haute énergie. Comme l'approche proposée permet la décomposition du signal en ses diverses composantes, une étude sur l'importance du signal de fluorescence dans l'effet de tige a été effectuée pour une multitude de modalités d'irradiation. Finalement, un détecteur à 3 points de mesure et une seule fibre optique collectrice a été utilisé en curiethérapie à haut débit de dose et inséré dans un unique cathéter pour effectuer la mesure de dose dans un fantôme d’eau. Sa capacité de mesurer efficacement la dose en de multiples positions simultanément a été démontrée. Un budget d'incertitude a aussi été effectué afin d'évaluer les limites sous lesquelles ce détecteur peut être utilisé comme potentiel dosimètre in vivo en clinique pour la curiethérapie à haut débit. / The goal of this thesis is to develop new plastic scintillation dosimetry systems to enable the measurement of in vivo doses in real time and the verification of the treatment delivery accuracy for radiation therapy, especially for high dose rate brachytherapy. The necessity to account for the stem effect light produced in the optical guide by radiation was first shown. The detector built for this study was then used to verify its accuracy to measure dose in real time during the delivery of a typical prostate treatment plan in high dose rate brachytherapy. This measurement was performed inside a water phantom. Dose deposited at each dwell position, inside each catheter and for the entire treatment delivery was measured and compared to the treatment planning system. Another part of this research project was on the development of an approach to render possible measurement at multiple positions with the use of multiple scintillating elements and only a single collecting optical guide. Plastic scintillation detectors with 2 and 3 points of measurement were first developed and used under external beam high energy radiation therapy. The approach enabled the calculation of different signal contributions over the total optical signal; a study was then performed to evaluate the importance of the fluorescence component on the total stem effect under a variety of irradiation modalities and conditions. Finally, a 3-point detector was inserted inside a single catheter to perform dosimetry under Ir-192 high dose rate brachytherapy in a water phantom. Its accuracy to measure dose was demonstrated. An uncertainty budget was also calculated in order to evaluate the limitations of this detector for its clinical potential as a real-time in vivo dosimeter.
16

Amélioration du calcul de dose TG-43 en curiethérapie à bas débit par un algorithme de dose primaire et diffusée sur processeur graphique

Bourque, Alexandre 19 April 2018 (has links)
Les calculs de dose en curiethérapie à bas débit reposent depuis 1995 sur un formalisme qui considère le milieu irradié comme étant homogène et constitué d’eau afin de mieux accommoder les temps de calcul clinique. Ce travail présente une amélioration de ce formalisme dosimétrique issu du protocole TG-43 de l’AAPM (American Association of Physicists in Medicine), utilisé actuellement dans les systèmes de planification de traitement (SPT) clinique. Avec l’ajout d’un tracé radiologique pour tenir compte des hétérogénéités et en séparant la dose primaire de la dose diffusée, il est possible de raffiner les calculs dosimétriques. Or, cette modification au calcul le rendant plus complexe était coûteuse en temps d’exécution jusqu’à très récemment. Elle se voit matérialisée dans ce travail avec l’arrivée récente de la technologie GPGPU, les calculs scientifiques sur périphériques graphiques. En exploitant le parallélisme des calculs de dose en curiethérapie à bas débit pour les implants permanents, l’algorithme baptisé TG-43-RT pour TG-43 avec tracé de rayons (Ray-Tracing en anglais) permet d’obtenir des facteurs d’accélération de l’ordre de 103 par rapport au CPU. Seulement 0.5 s par source est requis dans une géométrie de 1003 voxels, et les dosimétries d’anatomies hétérogènes sont sensiblement améliorées. Le TG-43-RT corrige les dépôts de dose en aval des hétérogénéités et réduit les effets indésirables de l’atténuation inter-sources. Des écarts de dose de plus de 80% au-delà d’une calcification avaient de quoi influencer les HDV, or, le TG-43-RT ramène ces déviations en-deçà de l’incertitude de 8.7% (2σ) concédée par les SPT, tel qu’établi dans le TG-138. Les simulations Monte Carlo ont été employées pour servir de référence absolue à la méthode développée et quantifier les améliorations dosimétriques relatives à l’actuel calcul de dose. L’algorithme a été testé d’un point de vue clinique dans un fantôme de prostate avec des sources d’125I et dans un fantôme de sein avec des sources de 103Pd pour unifier les corrections apportées. / Brachytherapy dose calculations have been relying since 1995 on a formalism that considers the whole geometry as a homogeneous water tank. This gives the opportunity to compute dose distributions within a reasonable clinical timeframe, but with considerable approximations that can influence or even change the treatment. This work presents an upgraded version of this formalism derived from the TG-43 protocol (AAPM), currently used in actual treatment planning systems. The new algorithm includes a primary and scatter dose separation using ray-tracing operation to account for heterogeneities through the medium. These modifications to the dose calculation are very power consuming and too long for the clinical needs when executed on modern CPUs. With the GPGPU technology, a GPU-driven algorithm allows a complex handling of the anatomic heterogeneities in the dose calculation and keeps execution times below 0.5 s/seed. The algorithm was named TG-43-RT for TG-43 with Ray-Tracing and accelerations factors of three order of magnitude were obtained over a regular CPU implementation. The TG-43-RT algorithm adequatly corrects dose deposition along heterogeneities and it reduces interseed attenuation effects. Dose is scored in the medium instead of water, which also applies a severe correction for high heterogeneous medium like the breast. Deviations of more than 80% in dose deposition were obtained over calcification inside the prostate when compared to Monte Carlo simulations. This kind of deviation influences DVH shape. However, the TG-43-RT was keeping those deviations within the 8.7% uncertainty range (2σ) associated with a regular TG-43 evaluation as stated in the TG-138. Monte Carlo simulations were used as a gold standard to get an absolute dose calculation reference. The algorithm was also tested in a prostate phantom with 125I seeds and in a breast phantom with 103Pd seeds to mimic real anatomic geometries and unify the applied corrections.
17

Développement du modèle de performances de SITELLE, spectromètre imageur à transformée de Fourier

Mandar, Julie 18 April 2018 (has links)
SITELLE est le nouveau spectromètre imageur à transformée de Fourier qui doit être installé au Télescope Canada-France-Hawaii. Le développement de son modèle de performance a permis d’évaluer les paramètres instrumentaux qui sont critiques par rapport aux exigences scientifiques. D’une part, une configuration hors-axe à miroirs plans a été sélectionnée pour répondre plus facilement à l’exigence de haute efficacité dans le proche ultraviolet. D’autre part, les critères d’asservissement ont été définis afin de concevoir un instrument limité par le bruit de photons pour une scène pertinente donnée. Ces performances doivent être maintenues pendant une acquisition totale de 4h sous des vibrations opérationnelles et toute vibration extérieure comme des bourrasques de vent sur le télescope. Enfin, le modèle de performance de SITELLE est au cœur du simulateur de rapport signal sur bruit qui permettra aux astrophysiciens d’évaluer les bénéfices potentiels de l’utilisation de ce spectromètre imageur pour leurs sujets d’études. / SITELLE is a new imaging Fourier transform spectrometer to be installed at the Canada-France- Hawaii Telescope. The development of its dedicated performance model drives the design of the instrument and the flow down of the science cases requirements into system requirements. First, the selected configuration with off-axis flat mirrors makes the achievement of a high efficiency in the near ultra violet easier. Secondly, servomechanism’s desirable performances were defined in order to design a photon noise limited instrument, based on a relevant scene. These performances should be maintained during a 4 hours data-cube acquisition, under operational vibrations and external effects such as wind gust hitting the telescope. Ultimately, this instrument performance model is the core of the signal to noise ratio simulator that will help observers to evaluate the potential benefits of SITELLE for their target.
18

Analyse des aberrations optiques du télescope de l'Observatoire du Mont-Mégantic

Laberge, Jonathan 18 April 2018 (has links)
Le télescope de l'Observatoire du Mont-Mégantic est utilisé depuis la fin des années 70. La grande variété d'instruments qui y est disponible en fait un télescope très polyvalent. Cependant, très peu de données existent par rapport à ses aberrations optiques. Il est important de connaître ces aberrations si on désire améliorer la performance optique du télescope. Pour évaluer ces aberrations, deux méthodes de reconstruction de front d'onde ont été utilisées : le senseur de front d'onde de type Shack-Hartmann et le senseur de courbure. L'analyse des fronts d'ondes reconstruits permet d'identifier les aberrations dominantes ainsi que plusieurs paramètres influençant ces aberrations. De plus, les méthodes sont comparées afin de vérifier si elles peuvent permettre un alignement des miroirs primaire et secondaire.
19

Étude par transport électrique de points quantiques colloïdaux

Lachance-Quirion, Dany 19 April 2018 (has links)
Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2012-2013. / Les points quantiques colloïdaux (cQD) sont des nanocristaux semiconducteurs permettant, d'un point de vue fondamental, l'étude des effets du confinement quantique. L'étude de ces effets dans les cQD se fait généralement par spectroscopie optique. Les quasi-particules alors étudiées sont des excitons, chacun composé d'une paire électron-trou en interaction. Il est alors a priori impossible de sonder optiquement les niveaux énergétiques des électrons et des trous séparément. La spectroscopie par transport électrique permet d'accéder aux niveaux d'énergie des quasi-particules uniques. De plus, comparativement à la spectroscopie par effet tunnel, il est possible de contrôler la charge du cQD par blocage de Coulomb. Ceci ouvre la porte à des études sur l'effet de charges excédentaires sur les propriétés optiques de cQD par la combinaison de la spectroscopie optique et celle par transport. La spectroscopie par transport électrique d'un cQD peut être réalisée à l'aide d'un transistor à un électron composé d'un cQD unique [l]. Dans ce but, des échantillons possédant la structure à trois terminaux d'un transistor sont fabriqués sur des substrats de silicium sur lesquels une couche d'oxyde de silicium est présente. La source et le drain sont séparés d'une distance nanométrique, nommée nanogap, par gravure à l'aide d'un faisceau focalisé d'ions de gallium. Une grille locale, permettant le contrôle électrostatique du cQD, est située à environ 100 nm du nanogap, où le cQD est connecté. Les fuites de courant entre les terminaux des dispositifs sans cQD sont de l'ordre de 100 GQ, ce qui est suffisant pour permettre l'étude des cQD par transport électrique. Des mesures de transport à deux terminaux sont effectuées à température de la pièce après l'incorporation de cQD de CdSe et de CdSe/CdS à coquille épaisse d'environ 4.2 nm et 12.7 nm de diamètre respectivement. Les tensions de seuil à partir desquelles le courant circule dans le dispositif correspondent approximativement à celles prédites par un modèle de confinement quantique fini. De plus, les mesures de transport révèlent la présence de bruit télégraphique montrant de deux à trois paliers de courant avec des variations relatives aussi grandes que ±20% par rapport à la valeur moyenne du courant. Le bruit télégraphique en transport et le phénomène de clignotement observé en photoluminescence ont potentiellement comme origine commune la présence de charges capturées dans des états de pièges à la surface des cQD.
20

Neutral dissociation of superexcited molecules in a strong laser field

Azarm, Ali 19 April 2018 (has links)
L'objectif principal de cette thèse est de rendre compte d'une étude expérimentale sur la dissociation neutre de molécules simples dans un champ laser intense créé par un cristal titane saphir. Ces excitations fortement non linéaires nous indiquent que les molécules peuvent être peuplées dans les états hyperexcités. Dans ce travail, un laser titane saphir femtoseconde est utilisé pour amener les molécules de H₂, 0₂, NO, CH₄, C₂H₄, C₃, H₆, 1 — C₄H₈ et cis — 2 — C₄H₈ dans les états très excités. En utilisant une méthode de spectroscopic, on arrive à détecter des signaux de fluorescence. Le diagramme d'énergie des fragments excités et molécules neutres supporte l'excitation des états hyperexcités dans les molécules que nous avons étudiées. La dépendance hautement non linéaire du rendement produit selon la puissance du laser a été observée. En outre, les résultats soutiennent le mécanisme d'hyperexcitation multiphotonique. En utilisant la technique de pompe (800 nm) et sonde (1338 nm) et aussi de la technique de spectroscopie par fluorescence, nous confirmons le mécanisme de hyperexcitation multiphotonique des molécules en présence d'un champ laser intense. Nous arrivons à déterminer la durée de vie des états hyperexcités en regardant l'atténuation des signaux de fluorescence observée à l'aide du faisceau sonde. Nos observations expérimentales ont été également vérifiées à l'aide des calculs semi—empiriques. Nous constatons que certaines impulsions laser provoquent la dissociation neutre de nombreuses molécules.