• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 1
  • Tagged with
  • 129
  • 129
  • 129
  • 103
  • 101
  • 53
  • 36
  • 35
  • 34
  • 33
  • 32
  • 32
  • 31
  • 31
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo de um inversor fotovoltaico para controle e compensação de reativos e harmônicos / Study of a photovoltaic inverter for reactive and harmonic control and compensation

Souza, Wallace Gabriel de 18 May 2018 (has links)
Submitted by Wallace Gabriel de Souza (wgs.gabriel@hotmail.com) on 2018-07-16T16:35:11Z No. of bitstreams: 1 dissertacao_wgs.pdf: 3537876 bytes, checksum: 56fef2d280007dba43983b71988d997b (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-07-17T13:07:06Z (GMT) No. of bitstreams: 1 souza_wg_me_bauru.pdf: 3537876 bytes, checksum: 56fef2d280007dba43983b71988d997b (MD5) / Made available in DSpace on 2018-07-17T13:07:06Z (GMT). No. of bitstreams: 1 souza_wg_me_bauru.pdf: 3537876 bytes, checksum: 56fef2d280007dba43983b71988d997b (MD5) Previous issue date: 2018-05-18 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta dissertação apresenta o desenvolvimento e as simulações computacionais de um inversor fotovoltaico de 2,0 kVA para o controle da potência reativa na rede de distribuição, de modo que haja compensação ativa do fator de potência e aumento da qualidade da energia no local da instalação da planta. Para atingir este objetivo, por meio do ambiente de desenvolvimento do MATLAB/Simulink®, o controle da potência ativa foi realizado pelo ajuste do ângulo entre a tensão da rede e a tensão gerada pelo inversor, por meio do equilíbrio do potencial do barramento CC (proveniente do gerador fotovoltaico). A potência reativa, por sua vez, foi ajustada pela amplitude da tensão do ponto de acoplamento de uma carga local. Além disto, utilizaram-se controladores proporcionais-ressonantes nas malhas de tensão e corrente do conversor trifásico, com finalidade de mitigar as correntes harmônicas de cargas não-lineares que podem depreciar o fator de potência. Foi implementado, também, um conversor CC-CC isolado full-bridge do tipo boost com potência nominal de 1,8 kW, responsável por rastrear o ponto de máxima potência dos módulos fotovoltaicos. Os resultados obtidos permitiram a avaliação do desempenho dos controladores e a observação da conservação, pelo inversor, do fator de potência da rede próximo da unidade para situações com variações acentuadas da carga e da irradiação solar, bem como para os casos com a presença de cargas não-lineares no sistema. Com isso, o perfil de tensão entregue à carga é aproximadamente senoidal, com baixa distorção harmônica. / This dissertation presents the development and computational simulations of a 2.0 kVA photovoltaic inverter for the control of the reactive power in the distribution network, so that there is active power factor compensation and an increase in the quality of the energy at the installation site plant. In order to reach this objective, the MATLAB/Simulink® development environment was used to control the active power by adjusting the angle between the grid voltage and the voltage generated by the inverter, by means of the potential balance of the DC (from the photovoltaic generator). The reactive power, in turn, was adjusted by the amplitude of the voltage of the coupling point of a local load. In addition, resonant-proportional controllers were used in the voltage and current loops of the three-phase converter, in order to mitigate the harmonic currents of non-linear loads that may depreciate the power factor. A full-bridge, full-bridge boost converter with nominal power of 1.8 kW was also implemented, responsible for tracking the maximum power point of the photovoltaic modules. The results obtained allowed the evaluation of the performance of the controllers and the observation of the conservation by the inverter of the power factor of the network close to the unit for situations with marked variations of the load and the solar irradiation, as well as for the cases with the presence of loads in the system. Thus, the voltage profile delivered to the load is approximately sinusoidal, with low harmonic distortion. / 2016/03734-3
42

Classificação de distúrbios de energia elétrica baseada em sistemas imunológicos artificiais

Arruda, Bruno Willian de Souza 10 February 2015 (has links)
Submitted by Maria Suzana Diniz (msuzanad@hotmail.com) on 2015-11-06T14:05:54Z No. of bitstreams: 1 arquivototal.pdf: 2092102 bytes, checksum: 1fd93fe1d9dbe62fb49d94dfd1cfdbdb (MD5) / Made available in DSpace on 2015-11-06T14:05:54Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2092102 bytes, checksum: 1fd93fe1d9dbe62fb49d94dfd1cfdbdb (MD5) Previous issue date: 2015-02-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Nowadays, electricity assumes an essential role in the sustainability of modern society. The requirement and consumer demand for power quality are growing along with the advancement of technology and the increasing use of non-linear loads. This paper presents an application of artificial immune systems, focusing on the clonal selection algorithm, for power quality disturbances classification. The algorithm uses an initial population of antibodies to generate high affinity memory cells capable of recognizing antigenic electrical disturbances during each half cycle of the fundamental frequency voltage signal. The results demonstrate the algorithm's ability to classify disturbances such as sag, swell, outage and harmonics, with 100% efficiency rating. Another important feature of this approach is that it can be embedded, since the online stage classification has a low computational complexity with processing time around 103 μs. Based on comparative study with other studies, the results showed up best. / Na atualidade, a energia elétrica assume um papel imprescindível para a sustentabilidade da sociedade moderna. Com o avanço da tecnologia e a utilização cada vez maior de cargas não-lineares, são crescentes a exigência e a demanda dos consumidores em relação à qualidade de energia elétrica. Neste trabalho é apresentada uma aplicação de sistemas imunológicos artificiais, tendo como foco o algoritmo de seleção clonal, para classificação de distúrbios de energia elétrica. O algoritmo utiliza uma população inicial de anticorpos para gerar células de memória de alta afinidade antigênica capazes de reconhecer distúrbios de energia elétrica a cada meio ciclo da frequência fundamental do sinal de tensão. Os resultados obtidos demonstram a capacidade do algoritmo em classificar distúrbios, tais como afundamentos, elevações, interrupções e harmônicos, com 100% de eficiência de classificação. Outra característica importante desta abordagem é que ela pode ser embarcada, uma vez que a fase online de classificação apresenta baixa complexidade computacional com tempo de processamento em torno de 103 μs. Baseado no estudo comparativo com outros trabalhos, os resultados obtidos apresentaram-se melhores.
43

Compensadores estáticos de reativos empregados em redes de baixa tensão com geradores distribuídos de energia / Static var compensators applied in low voltage grids with distributed generators

Almeida, Felipe Augusto Ferreira de [UNESP] 03 November 2016 (has links)
Submitted by Felipe Augusto Ferreira de Almeida null (felipeafalmeida@gmail.com) on 2016-12-20T16:56:04Z No. of bitstreams: 1 DISSERTACAO_FELIPE_FINAL.pdf: 3666708 bytes, checksum: 18899b06cbe9a7091fd3f037b0656174 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-22T10:53:09Z (GMT) No. of bitstreams: 1 almeira_faf_me_bauru.pdf: 3666708 bytes, checksum: 18899b06cbe9a7091fd3f037b0656174 (MD5) / Made available in DSpace on 2016-12-22T10:53:09Z (GMT). No. of bitstreams: 1 almeira_faf_me_bauru.pdf: 3666708 bytes, checksum: 18899b06cbe9a7091fd3f037b0656174 (MD5) Previous issue date: 2016-11-03 / Instituto Federal de Educação, Ciência e Tecnologia de São Paulo (IFSP) / Este trabalho aborda o emprego do Compensador Estático de Reativos (SVC) em redes de baixa tensão com geração distribuída de energia, tendo como objetivo a compensação de tensão e de fator de potência. Os principais distúrbios de qualidade de energia elétrica em baixa tensão, bem como as normas e os limites operacionais para os principais indicadores foram revisados, visando confrontação com as situações resultantes da integração do SVC no sistema elétrico. O SVC possui operação estabelecida como carga reativa controlável em sistemas de transmissão de energia, fazendo parte dos condicionadores da tecnologia FACTS (Flexible AC Transmission Systems). A exploração desta tecnologia em outro nível de tensão é o objetivo deste trabalho. As análises foram realizadas através de simulações computacionais, desenvolvidas no ambiente MATLAB, contemplando o desenvolvimento de modelos relacionados com aplicações de RCT (Reator Controlado a Tiristor), FC (Capacitor Fixo), do CCT (Capacitor Chaveado a Tiristor) e de um sistema de geração distribuída de energia elétrica trifásico em uma rede de baixa tensão a quatro fios. A metodologia para o dimensionamento dos elementos passivos dos condicionadores é apresentada, bem como a análise dos valores de potência reativa, fator de potência, distorções harmônicas e a avaliação da necessidade de utilização ou não de filtros passivos. A teoria da potência conservativa (TPC) é a metodologia utilizada para definição das grandezas elétricas e fatores de conformidade. Por fim, as características operacionais de um SVC aplicado a uma rede de baixa tensão a quatro fios são exploradas através dos resultados de simulação, com o objetivo de demonstrar a manutenção de suas características operacionais estabelecidas, no nível de baixa tensão, e apontar aspectos diferenciados quanto à regulação de fator de potência e da forma de tensão providos pelo SVC, para servir como informação de confronto frente a outras tecnologias comumente utilizadas neste nível de tensão. / This paper discusses the use of Static Var Compensator (SVC) on low voltage grids with distributed generation with the aim of voltage and power factor compensation. The main electrical power quality disturbances at low voltage as well as the rules and operational limits for the main indicators were reviewed aiming to confront the situations resulting from SVC integration in the electrical system. SVC has established operation as controllable reactive load in power transmission systems, being part of FACTS (Flexible AC Transmission Systems) technology conditioners. The application of this technology in another level of tension is the objective of this work. The analyzes were carried out through computer simulations developed in the MATLAB environment, including the development of models related to RCT (Thyristor Controlled Reactor), FC (Fixed Capacitor), CCT (Thyristor Switching Capacitor) and a threephase electric power distributed generation system in a four-wire low voltage grid. The methodology for the dimensioning of the passive elements of the conditioners is presented, as well as the analysis of the values of reactive power, power factor, harmonic distortions and the evaluation of the need to use passive filters. The conservative power theory (CPT) is the methodology used to define the electrical magnitudes and compliance factors. Finally, the operational characteristics of a SVC applied to a low-voltage four-wire network are exploited through the simulation results, in order to demonstrate the maintenance of its established operational characteristics at the low voltage level and to point out different aspects as well as the power factor regulation and voltage form provided by the SVC, to serve as confronting information.
44

Análise de um compensador estático paralelo monofásico visando a melhoria do fator de potência / Analysis of a parallel phase static compensator

Andrade, Adson íkaro Silva Leite de 17 November 2011 (has links)
Made available in DSpace on 2015-05-08T14:59:37Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2390386 bytes, checksum: 2877d7af65aad5521adb02a684322a1c (MD5) Previous issue date: 2011-11-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work consists of developing a control system power factor through the use of a parallel active filter. To this end, the control system of the filter is composed of an outer voltage loop and an inner current loop, based on PI controllers. For its development, it was observed that the application of parallel active filters offered by the literature, where it was realized that this type of filter is often used to correct the power factor for the development of control technique were made in modeling system and their analysis in steady state, after, the modeled system, the controllers were implemented and validated by numerical simulation using a test bench where he was led via DSP algorithm implemented PWM technique to control and command keys potency. / Este trabalho consiste no desenvolvimento de um sistema de controle do fator de potência através da utilização de um filtro ativo paralelo. Para tal, o sistema de controle do filtro é composto por uma malha externa de tensão e uma malha interna de corrente, baseadas em controladores PI. Para o desenvolvimento do mesmo, observaram-se as aplicações dos filtros ativos paralelos oferecidos pela literatura, onde se percebeu que esse tipo de filtro é bastante utilizado para a correção do fator de potência, para o desenvolvimento da técnica de controle foram feitas as modelagens do sistema e as suas respectivas análises em regime permanente, após, modelado o sistema, os controladores foram implementados via simulação numérica e validados através de uma bancada de teste comandada via DSP onde foi implementado o algoritmo de controle e a técnica PWM para o comando das chaves de potência.
45

Algoritmo híbrido e inteligente para o diagnóstico das condições operativas de  transformadores de potência no contexto da qualidade da energia elétrica / Hybrid intelligent algorithm for the diagnosis of operating conditions of power transformers in the context of power quality

Breda, Jáder Fernando Dias 12 July 2012 (has links)
Esta pesquisa teve como objetivo o desenvolvimento de um algoritmo computacional capaz de diagnosticar as condições operativas de transformadores de potência. As variáveis tomadas como base para classificar as condições apresentadas se referem às usualmente empregadas pela lógica de proteção diferencial, ou seja, a corrente diferencial e o conteúdo harmônico presente nos sinais em análise. Além disto, foi também verificada a relação entre alguns dos fenômenos associados à falta de qualidade da energia elétrica originados pelos consumidores conectados no secundário e refletidos ao primário do transformador. O algoritmo desenvolvido utilizou-se da Transformada Wavelet e de técnicas de inteligência artificial (Lógica Fuzzy e Redes Neurais Artificiais), com o objetivo de inferir sobre os relacionamentos supracitados. Todos os testes para validação da metodologia proposta foram realizados dispondo de um sistema elétrico simulado no software ATP (Alternative Transients Program). Os resultados encontrados denotam que, frente às condições analisadas, correntes diferenciais e conteúdo harmônico indesejado podem vir a surgir, fazendo com que a lógica implementada venha a diagnosticar erroneamente a condição de operação enfrentada. Os resultados avaliam ainda a propagação destas condições do secundário para o primário do transformador em análise. / This research aimed to develop an algorithm able to diagnose the operating conditions of power transformers. The variables considered to classify the presented conditions were the normally used by differential protection logic, i.e., the differential current and the harmonic content in the signals in analysis. Moreover, the relationship between some phenomena associated to a poor power quality originated from consumers connected to the secondary and reflect to the primary side of the transformer was also verified. In order to infer the relationships above mentioned, the developed algorithm used the Wavelet Transform and artificial intelligence techniques (Fuzzy Logic and Artificial Neural Networks). All the tests applied to validate the proposed methodology were performed making use of the ATP (Alternative Transients Program). In face of the analyzed conditions, the results show that differential currents and undesired harmonic content can arise and the implemented logic will erroneously diagnose the operation condition addressed. The results also illustrate the propagation of these conditions from secondary to primary side of the analyzed transformer.
46

Estudo investigativo da análise modal aplicada a sistemas de distribuição frente às distorções harmônicas / Investigative study of modal analysis applied to distribution systems within the scope of harmonic distortions

Golfieri, Carolina Iovance 25 September 2018 (has links)
Esta pesquisa apresenta um estudo investigativo da análise modal aplicada a Sistemas de Distribuição (SDs) frente às distorções harmônicas, no contexto da Qualidade da Energia Elétrica (QEE). A partir do método de análise da ressonância modal, foi conduzido um estudo investigativo para apontar quais barramentos são mais sensíveis e permitem uma melhor observação frente às distorções harmônicas. Vale adiantar que o método de análise de ressonância modal, o qual é fundamentado na decomposição espectral da matriz de admitância do sistema elétrico, já apresenta interessantes trabalhos voltados para sistemas de transmissão. O desafio desta pesquisa foi então investigar a sua aplicação para SDs com um direcionamento às distorções harmônicas, bem como ao seu monitoramento. Dentre os resultados encontrados no desenvolvimento da pesquisa, destaca-se um melhor entendimento do problema das distorções harmônicas, o qual permitiu evidenciar a sensibilidade e a observabilidade dos SDs testes frente ao problema definido no contexto da QEE. / This research presents an investigative study of the modal analysis applied to Distribution Systems (DSs) in the context of Power Quality (PQ) considering the harmonic distortions. From the modal resonance analysis, an investigative study was conducted to indicate which bus bars are more sensitive and allow better observation in face of harmonic distortions. It is worth mentioning that the method of modal resonance analysis, which is based on the spectral decomposition of the admittance matrix of the electric system, already presents interesting applications focused on transmission systems. The challenge of this research was to investigate its application to DSs focusing on harmonic distortions, as well as their monitoring. Among the observed results of the research development, a better understanding of the harmonic distortions problem was achieved, which made it possible to highlight the sensitivity and observability of the DSs tests against the problem defined in the context of the PQ.
47

Um algoritmo para detecção, localização e classificação de distúrbios na qualidade da energia elétrica utilizando a transformada wavelet / Detection, localization and classification algorithm for power quality disturbances using wavelet transform

Delmont Filho, Odilon 07 May 2007 (has links)
A Qualidade da energia elétrica é caracterizada pela disponibilidade da energia através de uma forma de onda senoidal pura, sem alterações na amplitude e freqüência. No entanto situações transitórias em sistemas de potência são comuns e estas podem provocar inúmeras interferências indesejáveis. Neste contexto, este trabalho tem como objetivo desenvolver um algoritmo para detectar, localizar no tempo e classificar diversos distúrbios que ocorrem no sistema elétrico através da aplicação da transformada wavelet (TW). Foi realizado um estudo teórico desde a origem até os recentes avanços sobre a TW. Para a detecção e localização no tempo foi utilizada apenas a TW. Com relação à classificação foram comparadas três ferramentas matemáticas: TW, TRF (Transformada Rápida de Fourier) e RNA (Redes Neurais Artificiais). Através do software ATP (Alternative Transients Program) foi modelado um sistema de distribuição, cujas características seguem um sistema real. Todos os distúrbios de tensão gerados e analisados puderam ser detectados e localizados no tempo através da técnica de análise multiresolução. Em relação à classificação, foi realizada uma comparação entre a TW, a TRF e RNA com resultados satisfatórios, destacando dentre elas a TRF e a RNA. Pode-se concluir que os resultados obtidos através do algoritmo mostraram-se eficientes tanto no aspecto da detecção, localização e classificação, assim como na estimação da amplitude do distúrbio e da duração do distúrbio. / A perfect power supply would be one that is always available, maintaining the supply voltage and frequency within certain limits, and supplying pure noise free sinusoidal waveform. Nevertheless, transient events are usual in power systems, resulting in several interferences. The purpose of this study is for detecting, locating in time and to classifying with wavelet transform (WT) several disturbances that occur on power systems. A WT theoretical revision, referring to the first mention in wavelet up to the recent research advances is presented. Only WT was used in order to detect and locate in time the power system disturbances. For classification, three mathematical tools were compared: WT, FFT (Fast Fourier Transform) and ANN (Artificial Neural Networks). A distribution System, with identical characteristics as the real distribution system, was performed with ATP software (Alternative Transients Program). The results showed that multiresolution analysis technique is able to detect and locate all the generated and analyzed voltage disturbances. For classification the results were similar for the WT, FFT and ANN, however FFT and ANN results presented a better performance. The results conclude that the WT algorithm is efficient at detecting, localizing and classifying power system disturbances, as well as, at estimating the amplitude and duration of the voltage disturbance.
48

Influência do sistema de aterramento na presença de distorção harmônica / Influence of the grounding system in the presence of harmonic distortion

Gamito, Marcos Aparecido Ruiz 13 October 2016 (has links)
Com o surgimento das novas tecnologias aplicadas aos equipamentos e arranjos geométricos das fontes renováveis de energia, o sistema de aterramento passou a operar com correntes de várias frequências, diferentes da componente fundamental. Estas correntes são provenientes das novas cargas não lineares conectadas e das condições de falta, tornando mais difícil a equipotencialização do sistema de aterramento, devido, principalmente, ao seu tamanho e sua geometria. Neste cenário, esta pesquisa tem como objetivo o estudo do comportamento de um sistema de aterramento operando na presença de correntes com distorção harmônica. Para a modelagem do sistema de aterramento teste, foi utilizada a teoria de linhas de transmissão, considerando parâmetros distribuídos, pela qual o condutor foi modelado em porções ao longo de seu comprimento. Para a modelagem e análise do sistema de aterramento foram utilizados o programa ATP (Alternative Transients Program) e uma ferramenta computacional comercial, com o intuito de validar os valores da resistência da malha de aterramento observados. Pelos resultados encontrados, têm-se argumentos para alertar os projetos futuros de sistemas de aterramento para a necessidade e uma melhor análise das situações operacionais passíveis de ocorrência no sistema elétrico que venham a apresentar uma composição harmônica diferente e não desprezível em relação ao componente fundamental. / With the rise of new technology applied to devices and geometric arrangements related to renewable energy sources, grounding systems have started to operate with currents of multiple frequencies, deviating from its fundamental component. These currents come from the connection of new nonlinear loads and fault conditions, which makes the equipotential bonding harder for the grounding system, mainly due to its size and geometry. In this scenario, this research aims to study the behavior of a grounding system operating in the presence of harmonically distorted currents. The transmission line theory was used to model the testing grounding system, based on distributed parameters, through which the conductor was modeled in increments along its length. For modeling and studying the grounding system, the ATP (Alternative Transients Program) and a commercial software tool were used in order to validate the resistance values observed in the grounding grid. Based on the results found, there are arguments to alert future grounding system projects about the need for a better assessment of operational scenarios likely to occur in the electrical system, which may display a different harmonic composition that is not negligible in relation to the fundamental component.
49

Desenvolvimento do sistema de potência elétrica em uma unidade móvel de irradiação por feixe de elétrons para tratamento de águas residuárias e efluentes industriais / Developing an electrical power system of a mobile electron beam accelerator to treatment of industrial wastewaters and effluents

Gaspar, Renato Rache 27 September 2018 (has links)
O tratamento de águas residuárias e efluentes industriais por irradiação com feixe de elétrons é uma técnica promissora, porém pouco difundida em território Brasileiro. O projeto e a construção de uma unidade móvel contendo um acelerador industrial de elétrons de 700 keV e 20 kW, pelo Instituto de Pesquisas Energéticas e Nucleares (IPEN), é inovador para demonstrar os efeitos e resultados positivos dessa tecnologia. O propósito é deslocar a unidade móvel às diversas empresas com interesse em tratamento dos resíduos líquidos, conectar-se ao sistema elétrico da mesma e iniciar o processo de tratamento por ionização, por meio da irradiação com feixe de elétrons. A conexão da unidade móvel ao sistema elétrico local pode representar um desafio, pela grande diversidade de tensões e distâncias envolvidas, e também pelas grandes injeções de conteúdo harmônico gerado pelo acelerador de elétron que podem afetar as cargas do sistema industrial, comumente sensíveis. Neste trabalho realizou-se uma análise do sistema de potência da unidade móvel, quanto à capacidade de interrupção, seletividade da proteção e níveis de curto-circuito adequados de forma a assegurar uma maior confiabilidade na operação. Ao final, projetou-se e construiu-se o painel elétrico de controle da unidade móvel de irradiação. Além disso, na obtenção de parâmetros operacionais à unidade móvel, realizaram-se simulações e medições no acelerador industrial de elétrons de 1,5 MeV e 37,5 kW, instalado no Laboratório de Fontes Intensas de Radiação, do Centro de Tecnologia das Radiações, as quais demonstraram a necessidade da inserção de um filtro para redução dos índices de distorção nos harmônicos dessa instalação radiativa fixa no IPEN. / The treatment of wastewater and industrial effluents by electron beam irradiation is a promising technique, however, not very widespread in Brazilian territory. The design and a construction of a mobile unit containing an electron beam accelerator of 700 KeV and 20kW, by the Nuclear and Energy Research Institute (IPEN) is innovative to demonstrate the effects and positive results of this technology. The aim is to move the mobile unit to several companies with interest in liquid waste treatment, and connect to the industry electrical system and start the ionization treatment process through electron beam. The mobile unit\'s connection to the local electrical system can be a challenge in behalf of the great diversity of voltages and distances involved, as well as the large injections of harmonic content generated by the electron beam accelerator that can affect sensitive loads in the industrial system. In this work, an analysis was made of the power system of the mobile unit, regarding interruption capacity, selectivity protection and adequate short circuit levels in order to assure a greater reliability in the operation. At the end, the control panel of the mobile unit, simulations and measurements were carried out at the 1.5 MeV and 37.5 kW electron beam accelerator, installed at the Intensive Radiation Technology Center, which demonstrated the necessity of applying of a filter to reduce the measured harmonic distortion.
50

Previsão de distorção harmônica em cargas residenciais utilizando redes neuro-fuzzy / Prediction of harmonic distortion in residential loads using neurofuzzy networks

MORAIS JÚNIOR, Albino Moisés Faro de 11 July 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-10-01T14:39:49Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Previsaodistorcaoharmonica.pdf: 4236129 bytes, checksum: bb47a1edb3151361639a5867d6c2c545 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-10-01T14:40:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Previsaodistorcaoharmonica.pdf: 4236129 bytes, checksum: bb47a1edb3151361639a5867d6c2c545 (MD5) / Made available in DSpace on 2018-10-01T14:40:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Previsaodistorcaoharmonica.pdf: 4236129 bytes, checksum: bb47a1edb3151361639a5867d6c2c545 (MD5) Previous issue date: 2018-07-11 / Este trabalho apresenta uma modelagem para DHTv%, DHTi% e harmônicos individuais utilizando previsões de um sistema ANFIS que aprende com dados medidos e prevê o comportamento da rede para valores futuros. Estas previsões podem ajudar a atender as normas nacionais de DHTv% estipuladas pela Agência Nacional de Energia Elétrica (ANEEL) através dos Procedimentos de Distribuição (PRODIST), como as normas internacionais de DHTi%., desta forma se antecipando às normas que atualmente são recomendativas, mas em um futuro próximo serão punitivas. A modelagem é realizada por meio de um sistema Neuro-Fuzzy denominado ANFIS, o qual utiliza rede neural para aprender o comportamento do sistema e ajuste dos parâmetros e regra Fuzzy para a determinação dos valores de saída do sistema levando em consideração o aprendizado da rede Neural. A grande vantagem desta ferramenta é o poder de se modelar padrões utilizando uma previsão de estado harmônico das cargas conectadas na baixa tensão, o que ajuda na criação de pseudomedidas para as redes de distribuição, onde é difícil e oneroso a obtenção de medições reais. Entre as aplicações práticas para esta ferramenta pode-se destacar a utilização dos valores previstos em substituição a valores anômalos medidos, a utilização em medidores de energia para prever e evitar a ultrapassagem dos valores de Distorção Harmônico estipulados em norma e a utilização como base para a previsão de harmônicas individuais, que podem ser utilizadas em estudos de fluxo de carga harmônicos. / This work presents a modeling for THDv%, THDi% and individual harmonics using predictions from an ANFIS system that learns with measured data and predicts the behavior of the network for future values. These forecasts can help meet national THDv% standards stipulated by the Agência Nacional de Energia Elétrica (ANEEL) through Distribution Procedures (PRODIST), such as THDi% international standards, thus anticipating the currently recommended standards, but in the near future will be punitive. The modeling is performed by means of a Neuro-Fuzzy system called ANFIS, which uses neural network to learn the behavior of the system and adjustment of the parameters and Fuzzy rule for the determination of the system output values taking into account the learning of the Neural network. The great advantage of this tool is the power of modeling standards using a prediction of the harmonic state of the connected loads in the low voltage, which helps in the creation of pseudomedidas for the distribution networks, where it is difficult and costly to obtain real measurements. Among the practical applications for this tool is the use of the predicted values instead of measured anomalous values, the use in energy meters to predict and avoid exceeding the values of Harmonic Distortion stipulated in standard and the use as a basis for the prediction of individual harmonics that can be used in harmonic load flow studies.

Page generated in 0.1049 seconds