• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 4
  • Tagged with
  • 13
  • 13
  • 9
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Contribution des technologies CPL et sans fil à la supervision des réseaux de distribution d'électricité / Contribution of PLC and wireless technologies to supervision of electric distribution networks

Lefort, Romain 03 February 2015 (has links)
Le déploiement d'une infrastructure de supervision permet une gestion plus intelligente des réseaux de distribution d'électricité comparé à un renforcement traditionnel pour répondre aux nouveaux enjeux de la maitrise de l'énergie (Consommations, EnR, VE, ...). Pour acheminer les données, les Courants Porteurs en Ligne (CPL) possèdent un atout majeur. En effet, cette technologie permet de superposer un signal de plus haute fréquence au signal électrique 50/60 Hz. Toutefois, le support de transmission est difficile et non maîtrisable. Ces travaux de recherche ont pour objectif d'apporter une contribution à cette problématique par l'élaboration d'une plateforme de simulation des réseaux pour des fréquences allant jusqu'à 1 MHz dans un but de transmission de données. Des éléments clés des réseaux sont traités de façon séparés puis assemblés pour estimer les performances des CPL « Outdoor » actuels. La variation du comportement des réseaux en fonction du temps et de la fréquence, en particulier des perturbations en tête d'installation clients sur 24h est étudiée. Les transformateurs entre les réseaux HTA et BT sont modélisés sous la forme d'un « modèle à constantes localisées » et d'un « modèle boite noire ». Les deux modèles sont appliqués sur un transformateur H61 100 kVA. Par la suite, une modélisation des câbles de distribution est proposée sous forme d'un « modèle cascadé ». Celle-ci est appliquée sur un câble souterrain BT. Chaque modèle est obtenu à l'aide de mesures d'impédances, et validé par des mesures de transmissions. Pour compléter, une étude préliminaire sur les communications radio mobile est réalisée pour la supervision des réseaux de distribution. / Establishing a supervisory infrastructure allows a better smart management than an expensive strengthening of distribution network to respond to new constraints at the energies control (Consumption, REN, EV ...). To transmit data, Power Line Communication (PLC) technologies present an advantage in this context. In fact, it enables a superposition of High Frequency (HF) signals on electrical signal 50/60 Hz. However, electric networks have not been developed to this application because of difficult propagation conditions. This research work makes a contribution to develop a simulation platform in objective to transmit data to 1 MHz. In first time, each network element is studied singly and in second time, together, to estimate "Outdoor PLC" transmission performance. The first element studied is the networks variation in function of frequency and time. Several 24h disturbance measurements on LV customers are presented. The second element is the transformers which established connection between Medium Voltage (MV) and Low Voltage (LV). The proposed modeling method is based on a "lumped model" and a "black box model". These models are applied to a 100 kVA H61 transformer most commonly used by French distribution system operator in rural and suburban networks. The third element is the power line used in MV and LV networks. The proposed modeling method is based on a "cascaded model" from the theory of transmission line. This model is applied to one power line used in LV underground network. Each model is obtained from various impedance measurements. To complete, an introductory study on mobile radio communication is performed to remote network distribution.
12

GPU-enhanced power flow analysis / Calcul de Flux de Puissance amélioré grâce aux Processeurs Graphiques

Marin, Manuel 11 December 2015 (has links)
Cette thèse propose un large éventail d'approches afin d'améliorer différents aspects de l'analyse des flux de puissance avec comme fils conducteur l'utilisation du processeurs graphiques (GPU). Si les GPU ont rapidement prouvés leurs efficacités sur des applications régulières pour lesquelles le parallélisme de données était facilement exploitable, il en est tout autrement pour les applications dites irrégulières. Ceci est précisément le cas de la plupart des algorithmes d'analyse de flux de puissance. Pour ce travail, nous nous inscrivons dans cette problématique d'optimisation de l'analyse de flux de puissance à l'aide de coprocesseur de type GPU. L'intérêt est double. Il étend le domaine d'application des GPU à une nouvelle classe de problème et/ou d'algorithme en proposant des solutions originales. Il permet aussi à l'analyse des flux de puissance de rester pertinent dans un contexte de changements continus dans les systèmes énergétiques, et ainsi d'en faciliter leur évolution. Nos principales contributions liées à la programmation sur GPU sont: (i) l'analyse des différentes méthodes de parcours d'arbre pour apporter une réponse au problème de la régularité par rapport à l'équilibrage de charge ; (ii) l'analyse de l'impact du format de représentation sur la performance des implémentations d'arithmétique floue. Nos contributions à l'analyse des flux de puissance sont les suivantes: (ii) une nouvelle méthode pour l'évaluation de l'incertitude dans l'analyse des flux de puissance ; (ii) une nouvelle méthode de point fixe pour l'analyse des flux de puissance, problème que l'on qualifie d'intrinsèquement parallèle. / This thesis addresses the utilization of Graphics Processing Units (GPUs) for improving the Power Flow (PF) analysis of modern power systems. Currently, GPUs are challenged by applications exhibiting an irregular computational pattern, as is the case of most known methods for PF analysis. At the same time, the PF analysis needs to be improved in order to cope with new requirements of efficiency and accuracy coming from the Smart Grid concept. The relevance of GPU-enhanced PF analysis is twofold. On one hand, it expands the application domain of GPU to a new class of problems. On the other hand, it consistently increases the computational capacity available for power system operation and design. The present work attempts to achieve that in two complementary ways: (i) by developing novel GPU programming strategies for available PF algorithms, and (ii) by proposing novel PF analysis methods that can exploit the numerous features present in GPU architectures. Specific contributions on GPU computing include: (i) a comparison of two programming paradigms, namely regularity and load-balancing, for implementing the so-called treefix operations; (ii) a study of the impact of the representation format over performance and accuracy, for fuzzy interval algebraic operations; and (iii) the utilization of architecture-specific design, as a novel strategy to improve performance scalability of applications. Contributions on PF analysis include: (i) the design and evaluation of a novel method for the uncertainty assessment, based on the fuzzy interval approach; and (ii) the development of an intrinsically parallel method for PF analysis, which is not affected by the Amdahl's law.
13

Reduced Order Modeling for Smart Grids’ Simulation and Optimization / Modélisation à ordre réduit pour la simulation et l'optimisation des réseaux intelligents

Malik, Muhammad Haris 28 February 2017 (has links)
Cette thèse présente l'étude de la réduction de modèles pour les réseaux électriques et les réseaux de transmission. Un point de vue mathématique a été adopté pour la réduction de modèles. Les réseaux électriques sont des réseaux immenses et complexes, dont l'analyse et la conception nécessite la simulation et la résolution de grands modèles non-linéaires. Dans le cadre du développement de réseaux électriques intelligents (smart grids) avec une génération distribuée de puissance, l'analyse en temps réel de systèmes complexes tels que ceux-ci nécessite des modèles rapides,fiables et précis. Dans la présente étude, nous proposons des méthodes de réduction de de modèles à la fois a priori et a posteriori, adaptées aux modèles dynamiques des réseaux électriques.Un accent particulier a été mis sur la dynamique transitoire des réseaux électriques, décrite par un modèle oscillant non linéaire et complexe. La non-linéarité de ce modèle nécessite une attention particulière pour bénéficier du maximum d'avantages des techniques de réduction de modèles.Initialement, des méthodes comme POD et LATIN ont été adoptées avec des degrés de succès divers. La méthode de TPWL, qui combine la POD avec des approximations linéaires multiples, a été prouvée comme étant la méthode de réduction de modèles la mieux adaptée pour le modèle dynamique oscillant.Pour les lignes de transmission, un modèle de paramètres distribués en domaine fréquentiel est utilisé. Des modèles réduits de type PGD sont proposés pour le modèle DP des lignes de transmission. Un problème multidimensionnel entièrement paramétrique a été formulé, avec les paramètres électriques des lignes de transmission inclus comme coordonnées additionnelles de la représentation séparée. La méthode a été étendue pour étudier la solution du modèle des lignes de transmission pour laquelle les paramètres dépendent de la fréquence. / This thesis presents the study of the model order reduction for power grids and transmission networks. The specific focus has been the transient dynamics. A mathematical viewpoint has been adopted for model reduction. Power networks are huge and complex network, simulation for power grid analysis and design require large non-linearmodels to be solved. In the context of developing “SmartGrids” with the distributed generation of power, real time analysis of complex systems such as these needs fast,reliable and accurate models. In the current study we propose model order reduction methods both a-priori and aposteriori suitable for dynamic models of power grids.The model that describes the transient dynamics of the power grids is complex non-linear swing dynamics model. The non-linearity of the swing dynamics model necessitates special attention to achieve maximum benefit from the model order reduction techniques. In the current research, POD and LATIN methods were applied initially with varying degrees of success. The method of TPWL has been proved as the best-suited model reduction method for swing dynamics model ; this method combines POD with multiple linear approximations.For the transmission lines, a distributed parameters model infrequency-domain is used. PGD based reduced-order models are proposed for the DP model of transmission lines. A fully parametric problem with electrical parameters of transmission lines included as coordinates of the separated representation. The method was extended to present the solution of frequency-dependent parameters model for transmission lines.

Page generated in 0.0807 seconds