• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1438
  • 201
  • 65
  • 65
  • 65
  • 64
  • 40
  • 15
  • 15
  • 15
  • 11
  • 10
  • 7
  • 2
  • 2
  • Tagged with
  • 1671
  • 625
  • 519
  • 402
  • 369
  • 313
  • 276
  • 274
  • 234
  • 210
  • 184
  • 163
  • 136
  • 136
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
571

Avaliação da liberação de flúor de resinas compostas em água e ciclagem de pH / Evaluation of the fluoride release from composed resins in water and in pH - cycling system.

Garcez, Rosa Maria Viana de Braganca 01 March 2001 (has links)
O flúor tem um papel importante na estrutura dentária diminuindo a desmineralização e potencializando a remineralização. É fundamental conhecer o comportamento dos materiais restauradores no que diz respeito a liberação de flúor, não só em água deionizada, mas também em condições de desafio ácido. O objetivo desse trabalho foi avaliar a liberação de flúor de 6 materiais restauradores, em dois meios de imersão, água deionizada e sistema de ciclagem de pH entre, por 15 dias. Os materiais utilizados foram o Vitremer(VIT), o Dyract (DYR), o Ariston (A), o Tetric Ceram (TET), o Definite (DEF) e o Z 100. Para cada material foram confeccionados 16 corpos-de-prova na forma de discos (11 mm de diâmetro e 1,5 mm de espessura), os quais foram armazenados individualmente em 4 ml de cada solução, sendo 8 para cada meio de imersão. Na ciclagem de pH, o material era mantido 6 horas na solução desmineralizante e 18 horas na solução remineralizante. As soluções foram trocadas diariamente e os espécimes armazenados durante 15 dias. A liberação de flúor foi medida em 0,5 ml de solução adicionada a igual volume de TISAB II. Para os materiais Z 100, DEF e TET em água deionizada, a liberação de flúor foi obtida pela técnica da difusão facilitada por HMDS, nos períodos de 1, 7 e 15 dias. A análise da concentração de flúor foi medida por eletrodo específico para flúor, acoplado ao aparelho analisador de pH/F¯. Todos os materiais liberaram mais flúor no sistema de ciclagem de pH, exceto o Ariston. O pico de liberação foi maior no 1º dia, declinando do 2º dia em diante, e alcançando níveis baixos e constantes a partir do 7 º ao 15º dia. Os resultados foram submetidos a análise de variância a 3 critérios e ao teste de Tukey (p<0,05), para as comparações múltiplas. A liberação total no período do experimento em ordem decrescente, em água deionizada, em µgF¯/mm2 , foi A (3,6603), VIT (1,7529), DYR (0,2481), TET (0,0140), DEF (0,0086) e Z 100 (0,0020) e em ciclagem de pH, VIT (3,4366), A (2,1422), DYR (1,0691), TET (0,0297), Z 100 (0,0067) e DEF (0,0063). Assim concluímos que os materiais apresentaram padrão semelhante de liberação de flúor, exceto o Ariston, que mostrou comportamento estável e liberação constante durante os 15 dias, nos dois meios de imersão. Na ciclagem de pH, houve uma tendência de liberação de flúor de todos os materiais. / The fluoride has an important function in the dental structure reducing the desmineralization and increase the remineralization. It is fundamental to know the behavior of the restoratives materials relative the fluoride release, not only in deionized water, but also in conditions of acid challenge. The aim of the present study was to determine the fluoride release from 6 restoratives materials, in two storage solutions: deionized water and pH-cycling system solution over 15 days. 16 discs (11 mm diameter and 1,5 mm thickness) of materials, Vitremer (VIT), Dyract (DYR), Ariston pHc (A), Tetric Ceram (TET), Definite (DEF) and Z 100 were prepared and suspended individually in 4 mL of each solution, in number of 8 for each medium which was changed every 24 hours. In the pH-cycling system the specimens were immersed 6 hours in the demineralizing solution (pH 4,3) and 18 hours in remineralizing solution (pH 7,0). The solutions were changed daily during a period of 15 days. The fluoride release was determined after buffering the solutions with an equal volume of TISAB II. For the materials Z 100, DEF, TET in deionized water, the fluoride concentration was obtained by the microdiffusion method (Taves) in the periods of 1, 7 and 15 days. The analysis of the fluoride ion concentration in the solutions was measured using a fluoride ion sensitive electrode and a potent iometer ion-analyzer pH/F¯. The results of fluoride concentration in solutions eretransformed into released fluoride amount per material area (µgF¯/mm 2 ). All the materials released more fluoride in the pH-cycling system, exception Ariston. The release peak was larger in the 1st day, dropped at the 2nd and then remained constant from 7º to 15th day. The Ariston showed stable behavior, with small variations along the experiment. The results were submited to statistical analysis by ANOVA and the diferences between the treatments by the Tukey test (p<0,05). In deionized water, fluoride release in mgF¯/mm 2 was A(3,6603), VIT(1,7529), DYR (0,2481), TET (0,0140), DEF (0,0086) and Z 100 (0,0020) and, in pH-cycling system VIT (3,4366), A (2,1422), DYR (1,0691), TET (0,0297), Z 100 (0,0067) and DEF (0,0063), during the whole experimental period.
572

Biocompatibilidade da resina acrílica de prótese ocular : análise in vitro e in vivo /

Silva, Emily Vivianne Freitas da. January 2018 (has links)
Orientador: Marcelo Coelho Goiato / Coorientador: Sandra Helena Penha de Oliveira / Coorientador: Daniela Micheline dos Santos / Resumo: O objetivo desse estudo foi avaliar a influência de diferentes ciclos e métodos de polimerização da resina acrílica (RA) branca de próteses oculares sobre a biocompatibilidade de células da conjuntiva humana e resposta inflamatória do tecido subcutâneo de ratos. Para isso, foram confeccionados corpos de prova em RA termopolimerizados em água aquecida (RNAA), por energia de microondas (RNTM) e quimicamente ativados (RNQA). Para a análise in vivo, a resposta inflamatória desses 3 grupos (n=20/grupo) foi avaliada no tecido subcutâneo de 20 ratos Wistar por 7, 15, 30 e 60 dias (d). Células inflamatórias foram contadas no tecido adjacente ao corpo de prova após coloração com hematoxilina e eosina. A análise imunohistoquímica foi realizada para a detecção de IL-1β, IL-6, TNFα, IL-17 e CCL20. Para a análise in vitro, diferentes ciclos de polimerização para cada método citado foram avaliados, totalizando 11 grupos (n=8/grupo). Foram realizadas análises de grau de conversão (GC), MTT, Alamar Blue, ELISA, RT-PCR em tempo real e dupla marcação de Anexina V e iodeto de propídio. Dados quantitativos foram submetidos à Análise de Variância e ao teste de Tukey com significância de 5%. Os resultados qualitativos foram comparados visualmente. Na análise in vivo, houve infiltrado inflamatório moderado para os grupos RNTM e RNQA e leve para o grupo RNAA após 7 d. O infiltrado inflamatório e a imunomarcação dos alvos testados diminuiu gradativamente ao longo dos 60 d. O grupo RNTM exibiu mais cé... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of different cycles and methods of white color acrylic resin (AR) for ocular prosthesis on the biocompatibility of human conjunctival cells and on the inflammatory response of rat subcutaneous tissue. For this, AR specimens were prepared in water bath (NRWB), by microwave energy (NRME), and chemically activated (ANR). For in vivo analysis, the inflammatory response of these 3 groups (n=20/group) was assessed in subcutaneous tissue of 20 Wistar rats at 7, 15, 30 and 60 days (d). Inflammatory cells were counted in the tissue adjacent to specimen after staining with hematoxylin and eosin. The immunohistochemical analysis was performed for the detection of IL-1β, IL-6, TNFα, IL-17, and CCL20. For in vitro analysis, different cycles of polymerization for each method were evaluated, with a total of 11 groups (n=8/group). The degree of conversion (DC), MTT, ELISA, real-time RT-PCR and Annexin V and propidium iodide assays were performed. Quantitative data were submitted to Analysis of Variance and Tukey test with a 5% significance. Qualitative data were submitted to visual comparison. In in vivo analysis, there was a moderate inflammatory infiltrate for groups NRME and ANR, and a light infiltrate for the group NRWB after 7 d. The inflammatory infiltrate and the immunolabeling of tested targets decreased gradually during the 60 d. The group NRME exhibited the highest number of inflammatory cells, except for the group NRWB, which pre... (Complete abstract click electronic access below) / Doutor
573

Influência da interposição de diferentes cerâmicas no grau de conversão de agentes cimentantes resinosos /

Marinho, Márcio Leandro Von Dreifus. January 2010 (has links)
Orientador: Paulo Henrique dos Santos / Coorientador: Wirley Gonçalves Assunção / Banca: Eduardo Passos Rocha / Banca: Carlos Alberto dos Santos Cruz / Resumo: O objetivo deste estudo foi avaliar o grau de conversão de agentes cimentantes resinosos polimerizados sob diferentes espessuras de cerâmica feldspática e diferentes sistemas cerâmicos de mesma espessura. No primeiro estudo, oitenta amostras dos cimentos resinosos RelyX ARC (3M Espe) e RelyX Veneer (3M Espe) foram confeccionadas sob discos de cerâmica convencional Starlight (DeguDent) com espessuras de 0,5mm, 1,2mm, 1,8mm e 2,4mm. No segundo estudo, oitenta amostras dos cimentos resinosos RelyX ARC (3M Espe) e Maxcem Elite (Kerr) foram confeccionadas sob discos de diferentes sistemas cerâmicos: Starlight (DeguDent), Empress (Ivoclair Vivadent), E-max (Ivoclair Vivadent), In Ceram Alumina (Vita) e In Ceram Zircônia (Vita) com espessuras de 2,0mm. A leitura do grau de conversão dos cimentos resinosos foi realizada 10 minutos, 1 hora e 24 horas após a fotoativação dos cimentos, em espectrofotômetro FTIR Nexus 670 (Nicolet). Os resultados do primeiro estudo mostraram que o cimento resinoso dual RelyX ARC apresentou maior grau de conversão que o cimento fotoativado RelyX Veneer em todas as espessuras de cerâmica, inclusive sem interposição (p<0.0001). Os valores de grau de conversão obtidos após 1 hora e 24 horas não diferiram estatisticamente entre si (p=0.7433), mas foram superiores aos analisados após 10 minutos (p<0.0001). Para o cimento fotoativado, houve aumento gradativo no grau de conversão de 10 minutos até 24 horas (p<0.0001). No segundo estudo, os maiores valores de grau de conversão foram obtidos para as amostras polimerizadas sob as cerâmicas reforçadas por leucita e dissilicato de lítio, sem diferença estatisticamente significante entre si (p=0.1181), enquanto os menores valores do grau de conversão obtidos foram das amostras polimerizadas sob cerâmicas reforçadas por alumina e zircônia, sem diferença entre si (p=0.2374). Com base nos resultados destes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the degree of conversion of resin cements polymerized under different thicknesses of feldspatic ceramic and different ceramic systems with the same thickness. In the first study, eighty samples of RelyX ARC (3M Espe) and RelyX Veneer (3M Espe) were polymerized under conventional ceramic discs (Starlight, DeguDent) with thickness of 0.5 mm 1.2 mm, 1.8 mm and 2.4 mm. In the second study, eighty samples of RelyX ARC (3M Espe) and Maxcem Elite (Kerr) resin cements were polymerized over ceramics systems: Starlight (DeguDent), Empress (Ivoclar Vivadent), E-max (Ivoclar Vivadent), In Ceram Alumina (Vita) and In Ceram Zircon (Vita) with 2.0 mm of thickness. The degree of conversion of the resin cements was calculated 10 minutes, 1 hour and 24 hours after the curing of cements using a Nexus 670 FTIR spectrophotometer (Nicolet). The RelyX ARC showed higher values of degree of conversion than RelyX Veneer considering all the ceramics thickness in the first study. The measurements obtained after 1 hour and 24 hours did not differ significantly (p=0.7433), but were higher than those analyzed after 10 minutes (p<0.0001). Comparing the ceramic systems in the second study, the highest degree of conversion were obtained for samples polymerized under Empress and e.max ceramics, without statistically difference between them (p= 0.1181) and the lower values of conversion were obtained for the samples polymerized under In Ceram Alumina and In Ceram Zircon ceramics (p= 0.2374). Based on the results of these studies, we can conclude that the thickness of feldspatic porcelain as well as the ceramic system itself could influence the degree of conversion of light- and dual-cured resin cements. All the resin cements showed an increase on the degree of conversion after 24 hours, which could create an especial guideline for the clinical procedures using resin cements / Mestre
574

Influência do volume do preparo oclusal para inlays e do material restaurador na distribuição de tensão e resistência à fratura de pré-molares /

Costa, Anna Karina Figueiredo. January 2012 (has links)
Orientador: Alexandre Luiz Souto Borges / Coorientador: Pedro Yoshito Noritomi / Banca: Eduardo Shigueyuki Uemura / Banca: Rander Pereira Avelar / Resumo: O estudo avaliou a influência da dimensão do istmo oclusal do preparo em inlays na distribuição de tensões e resistência à fratura de pré-molares superiores humanos restaurados com diferentes tipos de materiais. Foram selecionados 49 dentes hígidos e separados em 7 grupos (n=7) de acordo com o volume do preparo: conservador ou extenso e material restaurador: cerâmica ou resina, tendo como controle os grupos I (Integro - controle positivo), PC (Preparo Conservador) e PE (Preparo Extenso), ambos controles negativos. Os demais grupos foram separados de acordo com o tipo de mateiral da Restauração: RCR- inlay Conservador + Resina indireta Signum Ceramis (Heraeus); RCC-inlay Conservador + Cerâmica e.max Press; RER-inlay Extensa + Resina composta Signum Ceramis e REC -inlay Extensa + Cerâmica e.max Press. Os dentes preparados foram moldados e os modelos confeccionados e enviados ao laboratório para a confecção das inlays. Todas as restaurações foram cimentadas com cimento resinoso, e armazenadas em ambiente úmido por 24 h. Os corpos de prova foram submetidos ao ensaio de resistência à fratura em máquina de ensaio universal a uma velocidade de 0,5 mm/min, por meio de uma ponta aplicadora de 10 mm de diâmetro que possuia contatos exclusivamente nas vertentes triturantes das cúspides vestibular e lingual. Todos os fraguimentos foram analisados com estereomicroscópio para o mapeamento das fraturas. Os dados obtidos foram submetidos ao teste ANOVA e Tukey em um nível de significância de 5% . Para a análise da distribuição de tensão e deslocamento um pré-molar birradicular foi modelado com dimensões médias da literatura e analisados por elementos finitos. No ensaio in vitro, o grupo I (161,73±22.94) apresentou valores médios de resistência à compressão, seguido... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The porpose of this study was to evaluate the influence of the size of the occlusal isthmus preparation of inlays, stress and displatimant distribution on fracture toughness of upper human premolars restored by two different materials. They were selected 49 intact teeth and separated into seven groups (n = 7). In accordance to the volume of Preparation: Extensive and Conservative, or Restorative material: Ceramic or Resin, with the control groups I (positive control), PC and PE (negative control). The other groups were divided into: RCR-conservative inlay + indirect resin Signum Ceramis (Heraeus), RCC- conservative inlay + e.max Press ceramic; RER-extensive inlay + indirect resin Signum Ceramis and REC- extensive inlay + e.max Press ceramic. The teeth were prepared by special controled device and the model cast was sent to the laboratory for the preparation of inlays. The restorations were cemented with resin cement. All groups were subjected to a resistance to fracture test in a universal testing machine at a cross speed of 0.5 mm / min, by the tip of 10 mm in diameter, only contact teeth . The slices was evaluated by stereomicroscopy and made the mapping of fractures. It was used the statistical analysis of variance and Tukey's test. For the analysis of stress distribuition and displacment of cuspal teeth, one upper premolar was modeled with average dimensions of the literature and analyzed by finite emement method. In the in vitro assay, the group I (161.73±22.94) showed mean values of compressive strength, followed by REC (103.55±15.84), RCC (94.38±12.35), RCR (90.31±6.10), RER (65.42±10.15), PC (65.46±5.37), PE (58.08±9.62). The stress distribution was different in all groups studied, and the tooth with extensive preparation showed higher concentration of tensile stress on the cervical region of the proximal... (Complete abstract click electronic access below) / Mestre
575

Efeito do preenchimento e do material restaurador na resistência à fratura e distribuição de tensões de pré-molares superiores fragilizados /

Souza, Ana Carolina de Oliveira. January 2012 (has links)
Orientador: Alexandre Luiz Souto Borges / Coorientador: Tathy Aparecida Xavier / Banca: Rubens Nisie Tango / Banca: Lucas Villaça Zogheib / Resumo: O objetivo deste trabalho foi avaliar a influência do tipo de preenchimento e material restaurador na distribuição de tensões e resistência à fratura de pré-molares superiores tratados endodonticamente e com cúspides socavadas. Foram selecionados 40 pré-molares superiores humanos hígidos, sendo que 5 foram deixados intactos como controle (Grupo C+) e o restante realizado tratamento endodôntico e socavamento das cúspides. Cinco dentes foram separados para compor o controle negativo (Grupo C-), os demais foram divididos em dois grupos de acordo com o material de preenchimento (cimento de ionômero de vidro e resina composta) e realizados preparos para inlays. Foram então subdivididos em três grupos, sem restauração (PC: preenchimento com ionômero de vidro, PR: preenchimento com resina composta direta), restaurados com resina composta indireta (CS: preenchimento com cimento de iônomero de vidro e RS: preenchimento com resina composta direta) e os restaurados com cerâmica (CE: preenchimento com cimento de ionômero de vidro e RE: preenchimento com resina composta direta). As restaurações foram cimentadas com cimento resinoso dual e armazenadas em água destilada a 37 ºC por 24 h. Cada corpo de prova foi submetido a carga de compressão em máquina de ensaios universal, com velocidade de 1 mm/min. Os dados de resistência à fratura foram submetidos à análise de variância e ao teste de Tukey (5%). Os oito grupos formados foram modelados, importados pelo software Ansys 13.0, os volumes de cada geometria convertidos em elementos tetraédricos e submetidos á análise estática estrutural dentro do limite elástico e linear. Os resultados mostraram que a remoção de estrutura dentária afetou significantemente a resistência à fratura. Os menores valores foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the influence of filling and restorative material on stress distribution and fracture resistance of premolars endodontically treated and weakened cuspal. Were selected 40 premolars healthy humans, 5 were left intact as controls (group C +) and others were performed endodontic treatment and removed the buccal and lingual dentin. Then 5 teeth were left to negative control (Group-C), the others were divided into two groups according to the filling material (glass ionomer and composite resin) and performed inlays prepares. They were then sudivided into three groups, no inlay restoration (PC: fill with glass ionomer, PR: fill with direct composite resin), restored with inlay made of indirect composite resin (CS: Fill glass ionomer (GIC) and RS: fill with resin composite) and restored with ceramic (EC: fill with VSD and RE: fill with resin composite). The restorations were cemented with dual cured resin cement and stored in distilled water at 37ºC/24h. Each specimen was compressed until the fracture in a universal testing machine with a 1mm/min of cross head speed. The eight groups were modeled, imported by software Ansys 13.0, the volume of each geometry were converted into tetrahedric elements and subjected to static structural analysis within the elastic limit and linear. Data fracture resistance were analysed by ANOVA and Tukey's test (5%). The results showed that removal of tooth structure affected significantly the fracture resistance values, the lowest were presented by the negative control group, followed by the groups restored and filled (no statistical difference between them) and all smaller than the control group positive. The different combinations of filling and restorative materials increased... (Complete abstract click electronic access below) / Mestre
576

Avalia??o quantitativa e qualitativa da rugosidade superficial de resinas compostas com nanoparticulas submetidas a diferentes m?todos de polimento

Costa, Catharina Simoni da 23 September 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:29Z (GMT). No. of bitstreams: 1 452168.pdf: 1481490 bytes, checksum: ac569335421ad138a02a15752e11a756 (MD5) Previous issue date: 2013-09-23 / Introduction : There are many tools on the market dental rotary for use in polishing of a restoration adhesive. As there are many choices, and the same manufacturer have more than one type of rotary apparatus of restoration, does not establish a single conduit to determine which tool to use composites containing nanoparticles. Objective : To evaluate, in vitro, the effect of two different polishing systems, based on a multi steps and on the quality and surface roughness of two composites nanoparticles. Materials and methods : The samples were prepared with nanofilled material resin Filtek Z 350 XT (3M ESPE) and nanoh?brid Tetric N Ceran (Ivoclar Vivadent). The samples were made in cylindrical molds measuring 3 mm X 6 mm. A single operator executed all procedures. Each group consisted of 20 samples: 1) ZXT-control (without polishing); TNC-2) control (without polishing); 3) ZXT Sof-Lex (Orange fine and Superfine); 4) ZXT Optrapol; 5) TNC Optrapol; 6) TNC Sof-Lex (Orange fine and Superfine). The surface roughness was assessed with porfilometry (Ra), SEM and AFM. Statistical analyses : For analysis of mean roughness Ra (um), the data were tested for normality of ANOVA, at a significance level of 5%. Once verified the normal distribution of the results, they were subjected to analysis of variance followed by Tukey's test with a significance level of 5%. Results : The qualitative and quantitative analyzes showed that resins polished with Optrapol showed higher surface roughness and polishing with Sof-Lex showed no statistical difference between the resins tested. The lowest roughness was obtained with the control group, with no statistical difference between the resins. Conclusion : Optrapol promotes greater roughness in the resins tested, and ZXT showed higher roughness. Polishing with Soft-Lex showed no statistically significant differences between the tested resins. The surface roughness of the resins with TNC was lower when compared with Optrapol. The lowest surface roughness was obtained by the control group. / Introdu??o : Existe no mercado odontol?gico muitos instrumentos rotat?rios para serem utilizados no polimento final de uma restaura??o adesiva. Como s?o muitas as op??es, e um mesmo fabricante tem mais de um tipo de instrumento rotat?rio para realizar a finaliza??o da restaura??o, n?o se estabelece uma conduta ?nica que determine qual o instrumento utilizar para resinas compostas que contenham nanopart?culas. Objetivo : Avaliar, in vitro, o efeito de dois diferentes sistemas de polimento, baseados em um e multi etapas, sobre a qualidade e rugosidade da superf?cie de duas resinas com nanopart?culas. Materiais e m?todos : As amostras foram confeccionadas com resina nanoparticulada Filtek Z 350 XT (3M ESPE) e nanoh?brida Tetric N Ceran (Ivoclar Vivadent ). As amostras foram confeccionadas em moldes cil?ndricos medindo 3 mm X 6 mm. Um ?nico operador executou todos os procedimentos. Cada grupo foi composto por 20 amostras: 1) ZXT-Controle (sem polimento); 2)TNC-Controle (sem polimento); 3) ZXT+ Sof-Lex (seq??ncia Laranja fina e superfina); 4) ZXT+ Optrapol; 5) TNC+ Optrapol ; 6) TNC+ Sof- Lex (seq??ncia Laranja fina e superfina ). A rugosidade de superf?cie foi avaliada com rugos?metro (Ra), MEV e AFM. Estat?stica : Para an?lise das m?dias de rugosidade Ra (&#956;m), os dados foram submetidos aos testes de normalidade de ANOVA, ao n?vel de signific?ncia de 5%. Uma vez verificada a distribui??o normal dos resultados, estes foram submetidos ? an?lise de vari?ncia, seguida pelo teste de Tukey com n?vel de signific?ncia de 5%. Resultados : As an?lises qualitativas e quantitativas mostraram que as resinas polidas com Optrapol apresentaram maior rugosidade superficial e o polimento com Sof-Lex n?o mostrou diferen?a estat?stica entre as resinas testadas. A menor rugosidade foi obtida com os grupos controle, sem diferen?a estat?stica entre as resinas. Conclus?o : Optrapol promove maior rugosidade nas resinas testadas, e ZXT apresentou maior rugosidade. O polimento com Soft-Lex n?o mostrou diferen?as estatisticamente significantes entre as resinas testadas. A rugosidade superficial das resinas foi menor com TNC, quando comparado com Optrapol. A menor rugosidade de superf?cie obtida foi pelo grupo controle.
577

Resistência adesiva de resinas com baixa contração de polimerização após envelhecimento da interface adesiva / Microtensile bond strength of polymerization o flow-shrinkage composite resins after aging

Bárbara Jarreta 19 February 2014 (has links)
Este trabalho avaliou in vitro a resistência à microtração de resinas compostas de baixa contração de polimerização em superfície dentinária após a degradação da interface adesiva. A amostra do experimento foi composta de 78 terceiros molares, sendo que 60 dentes foram divididos aleatoriamente em 6 grupos (n = 10) para o ensaio de microtração e 18 dentes adicionais (três dentes por grupo) foram utilizados para a análise da interface adesiva por meio da microscopia eletrônica de varredura (MEV). As variáveis de resposta quantitativas foram a resistência adesiva por meio do ensaio de microtração (Megapascal) e a classificação e cálculo dos valores percentuais dos tipos de fratura por meio de MEV. A análise estatística demonstrou que nos grupos NTC, o grupo Z250 apresentou diferença estatisticamente significante com os demais grupos K e P90, sendo estes semelhantes entre si. Após a realização da termociclagem observou diminuição nos valores de resistência nos grupos estudados, sendo que o grupo Z250 apresentou diferença estatisticamente significante em comparação ao grupo K e P90, que foram semelhantes entre si. A qualidade da interface adesiva por meio de MEV após o teste de microtração demonstrou que fraturas mistas foram prevalentes em todos os grupos avaliados. Em relação a interface adesiva, quando o sistema adesivo Clearfill SE Bond foi utilizado, pôde-se observar uma camada de adesivo espessa, camada híbrida e tags. No entanto, para o sistema adesivo P90, não foi possível observar camada híbrida, tags e foram observadas fendas interfaciais tanto às 24 horas como após envelhecimento. / This in vitro study evaluated the microtensile bond strength of polymerization of lowshrinkage composite resins in dentin surface after degradation of the adhesive interface. The sample of the study was composed by 78 third molars, 60 teeth were randomly divided into 6 groups (n = 10) for the microtensile testing and 18 additional teeth (three teeth per group) were used for the analysis of adhesive interface by means of scanning electron microscopy (SEM).The quantitative response variables were bond strengths to dentin through the microtensile test (Megapascal) and the classification and calculation of percentage values of theta peso fracture by SEM. Statistical analysis showed that the groups NTC, the Z250 group showed a statistically significant difference with others groups K and P90, which are similar to each other. After the performance of thermo cycling was observed decline in strength values of the studied groups, with the Z250 group showed a statistically significant difference when compared to the K group and P90, which were similar. The analysis showed the presence of mixed and adhesive fractures. Regarding the adhesive interface could be observed in P90 (NTC) and P90 (TC), presence cracks and gaps interfacial group. In the other groups was observed thick and dense layer Clearfill SE Bond and presence of tags into the tubules. Thus, it was concluded that the low polymerization shrinkage resins present lower average microtensile bond strength values both after 24 hours and after aging procedures of the adhesive interface. The quality of the adhesive interface by SEM after the microtensile test showed that mixed fractures were prevalent in groups Z250 (NTC), Z250 (TC), K (NTC), K (TC), P90 (NTC).And adhesive fracture was prevalent in the P90 group (CT).In relation the adhesive interface, when the adhesive system Clearfill SE Bond was used, it was noted a layer of thick adhesive, hybrid layer and tags. However, for the adhesive system P90, it was not possible to observe the hybrid layer, tags and interfacial cracks were observed both after 24 hours and after aging.
578

Avaliação clínica longitudinal de restaurações de uma resina composta bulk-fill em dentes posteriores / Longitudinal clinical evaluation of restorations of a bulk-fill composite on posterior teeth

Rodrigues, Roger Borges January 2016 (has links)
Objetivos: O objetivo deste ensaio clínico randomizado foi avaliar o comportamento de restaurações de resina composta bulk-fill em dentes posteriores (classes I e II). Metodologia: Dezessete pacientes que necessitavam de restaurações em pelo menos dois dentes posteriores foram selecionados para participar do estudo. As causas para indicação das restaurações foram: substituição de restauração deficiente de amálgama ou resina composta e/ou lesão de cárie. Em cada paciente foram realizadas duas restaurações. Randomicamente, uma cavidade foi restaurada com a resina nanohíbrida Esthet-X HD (grupo controle) e a outra restaurada com a resina Esthet-X HD associada à resina de baixa contração Surefil SDR Flow (grupo teste). Em ambos os grupos, um sistema adesivo convencional de dois passos (XP Bond) foi utilizado. Todos os pacientes receberam tratamento global para a atividade cariosa. Após um período de quatro anos, a qualidade das restaurações foi avaliada por 1 examinador previamente calibrado, através de uma modificação do método USPHS e através do método FDI. Os dados obtidos foram submetidos à análise estatística pelo teste não-paramétrico Mann-Whitney (p<0,05) e a concordância intra-observador avaliada através de teste Kappa. Resultados: No quarto ano de acompanhamento, 26 dentes (18 restaurações classe I e 8 classe II) foram avaliadas, e não foram observadas diferenças estatisticamente significantes entre as restaurações dos grupos controle e teste para os métodos de avaliação utilizados. Não houve falhas em nenhuma das restaurações ao longo do tempo. Conclusão: A qualidade das restaurações classe I e II com resina bulk-fill foi semelhante à das restaurações com resina nanohíbrida convencional. A técnica com resina bulk-fill mostrou bom desempenho clínico tão bom quanto a convencional durante os 4 anos de acompanhamento. / Objectives: The objective of this randomized clinical trial was to evaluate the behavior of bulk-fill composite restorations in posterior teeth (classes I and II). Methodology: Seventeen patients who required restorations on at least two posterior teeth were selected to participate in the study. The causes for indication of restorations were: replacement of deficient amalgam or composite resin restoration and/or caries lesion. In each patient, two restorations were performed. Randomly, one cavity was restored with Esthet-X HD nanohybrid composite (control group) and the other was restored with Esthet-X HD resin associated with the bulk-fill composite Surefil SDR Flow (test group). In both groups, a two-step total-etch adhesive system (XP Bond) was used. All patients received global treatment for carious activity. After a period of four years, the quality of the restorations was evaluated by a previously calibrated examiner, through a modification of the USPHS method and through the FDI method. The data were submitted to statistical analysis by the non-parametric Mann-Whitney test (p <0.05) and the intra-observer agreement was evaluated by Kappa test. Results: At the 4-year follow-up, 26 teeth (18 class I and 8 class II restorations) were evaluated, and no statistically significant differences between control and test groups were observed for both evaluation methods used. There were no failures in any of the restorations over time. Conclusion: The quality of class I and II restorations with bulk-fill resin was similar to that of conventional nanohybrid resin. The bulk-fill composite technique showed good clinical performance as well as the conventional one during the 4 years of follow-up.
579

Avaliação da resistência à fratura de dentes tratados endodonticamente com pinos pré-fabricados e resinas compostas variando a quantidade de remanescente dentário coronal / Fracture strength assessment of teeth endodontically treated, restored with prefabricated posts and compound resins, and varying amount of remaining coronal dental structure

Melo, Murilo Pereira de 17 February 2003 (has links)
O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l – com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll – com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III – sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV – sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável. / The aim of this study was to evaluate the remaining coronal dental structure influence of endodontically treated teeth, restored with prefabricated posts and two different types of resin filling cores, a dual cure resin (Enforce Core) and a photopolymerizing resin (Z-250). 40 extracted upper canine human teeth were used, divided into four groups of 10 specimens each: Group I – with coronal dental structure of 3mm restored with Enforce Core; Group II – with coronal dental structure of 3mm restored with Z-250; Group III – without any remaining coronal dental structure restored with Enforce Core; Group IV – without any remaining coronal dental structure restored with Z-250. After the complete restoration, the teeth were taken to a universal test machine, and then submitted to compression forces at 45º, until reaching the fracture of the restoration. The analysis of the results (ANOVA, p>0,05) showed no statistically significant difference between the teeth with or without coronal dental structure. In relation to the material used for the coronal filling, there has been a statistically significant difference. Higher fracture strength values were found in the group restored with photopolymerizing resin.
580

Avaliação da profundidade de polimerização através de testes de microdureza de duas resinas compostas de matrizes distintas em diferentes densidades de energia e períodos, utilizando LED como fonte fotoativadora / Evaluation of depth of cure by testing microhardness of two resin composites of different matrices in different energy densities and periods, using LED as a source photopolymerization

Cardia, Guilherme Saintive 31 May 2011 (has links)
O presente estudo objetivou avaliar a profundidade de polimerização através de testes de microdureza em dois tipos de resina composta com matrizes distintas utilizando um aparelho fotoativador do tipo LED, empregando-se diferentes densidades de energia, sendo avaliados no período inicial (baseline) e após 7 dias. O método utilizado foi o teste de dureza Knoop em amostras de dois compósitos fotoativáveis (P 90, 3M/ESPE, cor A2; Z 250, 3M/ESPE, cor A2). Os corpos-de-prova foram subdivididos em 8 grupos (n=10), metade realizado com cada resina testada. Cada grupo foi definido através de diferentes densidades de energia (600 mW/cm2 x 40s; 1000 mW/cm2 x 40s; 1000 mW/cm2 x 20s; 1400 mW/cm2 x 20s), cada corpo-de- prova obtinha 4 medidas, diferentes profundidades (0, 1, 2 e 3 mm). Cada corpo-de-prova foi confeccionado com o auxilio de uma matriz metálica, constituída por 3 partes, superior, intermediaria e inferior, cada uma com 1 mm de espessura e orifício central com diâmetro de 5 mm. Sobre cada parte preenchida com resina, era colocado um pedaço de tira de poliéster, sobre o qual, com uma lâmina de vidro era exercida uma pressão para promover uma superfície lisa e plana. A unidade fotoativadora utilizada foi LED, para conseguir as diferentes densidades de potência, anéis de plástico foram acoplados na ponta do aparelho fotoativador. A fotoativação foi realizada com a ponta da unidade fotoativadora em contato com a tira de poliéster colocada na parte superior do corpo-de-prova (0 mm). Assim , cada espécime era composto por três partes, cada uma com 1 mm de espessura. Logo após a fotoativação, as partes dos espécimes eram separadas e realizavam-se 5 impressões de dureza Knoop (dureza inicial), com carga de 50g durante 30s, em 4 superfícies, que eram: 1ª) superfície superior da parte superior do espécime, voltada para a fonte de luz (0 mm); 2ª) superfície inferior da parte superior do espécime (1 mm); 3ª) superfície inferior da parte intermediária do espécime (2 mm); e 4ª) superfície inferior da parte inferior do espécime (3 mm). Após 7 dias de estocagem numa estufa a 37ºC, novas leituras de dureza eram realizadas (dureza final). Verificou-se que: 1) A resina composta P 90 obteve menores médias dos valores de dureza Knoop em relação à outra resina composta estudada, Z 250; 2) Quanto maior a profundidade, menores alores de dureza Knoop foram mensurados; 3) Valores de dureza Knoop final foram maiores após 7 dias em comparação a dureza Knoop inicial; 4) De acordo com o aumento da densidade de potência, maiores médias dos valores de dureza Knoop foram mensurados. Esses resultados permitem concluir que: 1) A resina melhora sua propriedade de dureza num período de 7 dias; 2) Quanto maior a profundidade, menor a dureza; 3) quanto maior a densidade de potência utilizada neste trabalho, maior dureza foi avaliado; 4) a resina P 90 obteve valores inferiores a resina Z 250 avaliadas nas mesmas condições. / This study aimed to evaluate the depth of cure through microhardness tests on two types of resin composite with different matrices using LED curing unit, using different energy densities and are assessed during the initial (baseline) and after 7 days. Knoop hardness test was performed in samples made of two light cured composites (P 90, 3M/ESPE, A2; Z 250, 3M/ESPE, A2). The specimens were divided into 8 groups (n=10), and half of them were made with each composite resin tested. Each group was defined by different power densities (600 mW/cm2 x 40s, 1000 mW/cm2 x 40s, 1000 mW/cm2 x 20s; mW/cm2 1400 x 20s), each specimens obtained four measures, different depths (0, 1, 2 and 3 mm). Each specimens was made with the aid of a metal matrix, consisting of 3 parts, superior, intermediate and bottom, each with 1 mm thickness and center hole diameter of 5 mm. On each side filled with resin, was placed a piece of polyester strip, on which, with a glass slide was exerted pressure to promote a flat surface. A unit LED curing was used and to achieve different power densities, plastic rings were attached at the tip of the curing unit. The polymerization was carried out with the tip of the curing unit in contact with the polyester strip placed on top of the specimen (0 mm). Thus, each specimen was composed of three parts, each part with 1 mm thick. Immediately after curing, the parts of the specimens were separated and held up five impressions of Knoop hardness (initial hardness), with a load of 50g for 30s on 4 surfaces, which were: 1) the upper surface of the upper specimen directed to the light source (0 mm), 2) lower surface of the upper specimen (1 mm); 3) lower surface of the middle section of the specimen (2 mm) and 4) lower surface of the bottom of the specimen (3 mm). After 7 days of storage in an oven at 37°C, new hardness re adings were made (final hardness). It was found that: 1) The composite P 90 had lower average values of Knoop hardness in relation to the other studied composite, Z 250, 2) The greater the depth, lower Knoop hardness values were measured, 3) Final values of Knoop hardness were higher after 7 days compared with initial hardness, 4) In accordance with the increase of power density, higher average values of Knoop hardness were measured. These results indicate that: 1) The resin improves the hardness property over a period of 7 days, 2) The greater the depth, the lower the hardness, 3) the higher the power density used in this study, higher hardness was evaluated; 4 ) P 90 resin obtained values less than Z 250 resin, evaluated under the same conditions.

Page generated in 0.0328 seconds