• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1438
  • 201
  • 65
  • 65
  • 65
  • 64
  • 40
  • 15
  • 15
  • 15
  • 11
  • 10
  • 7
  • 2
  • 2
  • Tagged with
  • 1671
  • 625
  • 519
  • 402
  • 369
  • 313
  • 276
  • 274
  • 234
  • 210
  • 184
  • 163
  • 136
  • 136
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
581

Reparo em restaurações de resina composta : longevidade clínica e relevância para a odontologia / Repair composite restorations : clinical longevity and relevance to dentistry

Elias, Raquel Viégas 27 February 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T13:31:35Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reparo em restaurações de resina composta longevidade clínica e.pdf: 1079352 bytes, checksum: 9f6c511706af8ca0bce89d106f58b972 (MD5) / Made available in DSpace on 2017-06-21T13:31:35Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reparo em restaurações de resina composta longevidade clínica e.pdf: 1079352 bytes, checksum: 9f6c511706af8ca0bce89d106f58b972 (MD5) Previous issue date: 2016-02-27 / Sem bolsa / O reparo de restaurações com falhas é uma das alternativas de tratamento indicadas por preservar o máximo de tecido dentário sadio. É de fácil execução, baixo custo, confortável para o paciente e capaz de aumentar a longevidade da restauração e do dente. Apesar disso, ainda é pouco utilizado pelos dentistas como alternativa à substituição de restaurações com defeitos. Dúvidas persistem com relação ao protocolo clínico e a longevidade desse procedimento. Este trabalho objetiva revisar na literatura aspectos relevantes sobre reparo em restaurações de resina composta e avaliar, através de um estudo clínico, a influência do reparo sobre a sobrevivência de restaurações de resina composta em dentes anteriores, com acompanhamento de 4 a 15 anos. A revisão foi do tipo narrativa e através das principais bases de dados foram selecionados estudos clínicos prospectivos ou retrospectivos e revisões sistemáticas ou narrativas sobre reparo de restaurações em resina composta. Para o estudo clínico utilizou-se um banco de dados extraídos de 396 prontuários de pacientes atendidos em uma clínica odontológica privada que receberam 628 restaurações de resina composta do tipo híbrida, microhíbrida e microparticulada em dentes anteriores, realizadas entre os anos de 1994 e 2009. Do total de restaurações foram realizados 198 reparos (55 classes III/IV; 143 facetas), dos quais 36 (65.4%) e 91(63.6%), respectivamente, em classes III/IV e facetas, permaneceram íntegros durante o período de avaliação. A sobrevivência das restaurações reparadas foi o desfecho principal do estudo. O teste exato de Fisher foi utilizado para analisar as diferenças nas falhas dentro de cada categoria (a=0.05). O método Kaplan-Meier foi empregado para gerar as curvas de sobrevivência em 15 anos. Regressão de Cox multivariável permitiu investigar a influência das variáveis de interesse (gênero, arco, lado, tipo de dente, tipo de resina composta e cavidade) na sobrevivência das restaurações. A taxa de falha anual das restaurações de classes III e IV, quando o reparo foi considerado sucesso, foi de 3.2% após 15 anos de acompanhamento, subindo para 4.9% quando o reparo foi considerado falha. Para facetas, a taxa de falha anual foi de 10.4% após 10 anos quando o reparo foi considerado sucesso e de 17.8% quando o reparo foi considerado falha. O arco dentário interferiu significativamente na longevidade das restaurações, com taxa de sobrevivência maior quando inseridas no arco inferior. Restaurações realizadas nos incisivos centrais apresentaram significativamente taxa de sobrevivência menor em relação aos incisivos laterais e caninos, exceto quando o reparo foi considerado sucesso em classes III e IV. As facetas realizadas com a associação de uma resina microhíbrida com uma microparticulada, quando o reparo foi considerado sucesso, tiveram maior sobrevivência em relação às realizadas apenas com resinas microhíbridas. Nossos achados com tempo longo de acompanhamento indicam que o reparo em restaurações de resina composta realizadas em dentes anteriores aumenta significativamente a sobrevivência das restaurações sendo uma alternativa viável para o tratamento de restaurações de resina composta com falhas. No entanto, estudos que levem em consideração a causa de falha da restauração, reparo ou substituição e hábitos de vida do paciente são necessários. / The repair of restorations is one of the alternative treatment indicated to preserve healthy tooth tissue. It is a procedure easy to perform, inexpensive, comfortable for the pacient and able of extending the longevity of the restorations and the tooth. However, it is still very little used by dentists as an alternative to replacement of defective restorations. There are still doubt regard the clinical protocol and longevity of this procedure. This study reviewed in the literature relevant aspects of repair in composite restorations and evaluate, through a retrospective clinical study the influence of repair on the survival of composite restorations in anterior teeth with follow-up time of 4 to 15 years. The review narrative selected in the main databases were select prospective and retrospective clinical studies and systematic reviews or narratives about restorations repair in composite. For the clinical study used a database extracted from 396 records of 138 patients seen at a private dental clinical with 628 composites restorations hybrid, mycrohibrid and microfillin anterior teeth carried between the years 1994 and 2009. The survival of repaired restorations was the main outcome of the study. The Fisher’s exact test was used to analyze the differences in failures within each category (a=0.05). Kaplan-Meier method was used to generate survival curves at 15 years. A multivariate Cox regression analysis was used to investigate the influence of the variables of interest (material, age, gender, jaw, tooth, side, cavity) in restoration survival. In all restorations were performed 198 (55 classes III/IV, 143 facets) repairs, of which 36 (65.4 %) and 91 (63.6 %), respectively, in classes III / IV and veneers, remained intact during the evaluation period. The repair interfered significantly in the survival of restorations. Annual failure rate percentage of class III/IV restorations, when repair was considered successful was 3.2% up to 15- years of follow-up, increased to 4.9% when the repair was considered failure. Annual failure rate percentage for veneers was 10.4% after 10 years when repair was considered successful and 17.8% when repair was regarded as failed. The arch interfered significantly in longevity restorations with higher survival rate when fulfilled in the lower arch. Restorations in the central incisors had significantly lower survival rate compared to the lateral incisors and canines, except when the repair was considered successful in class III and IV. The type of resin influenced the survival of the restorations when the repair was considered successful. Restorations class III/IV with hybrid composite resin had a higher survival rate compared to microhybrid and hybrid, while for the veneers microfill resins presented higher survival rates than microhybridan hybrid composites. Our findings with long follow-up indicate that the repair in composite restorations in anterior teeth significantly increases the survival of restorations being a viable alternative to treatment failures in composite restorations. However, studies that take into account the cause of failure of restoration, repair or replacement and patient lifestyle habits are needed.
582

Avaliação instrumental da correspondência de cor de resinas compostas em função de escala de referência, tonalidade, composição e espessura

Portero, Priscila Paiva [UNESP] 26 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-26Bitstream added on 2014-06-13T19:20:03Z : No. of bitstreams: 1 portero_pp_dr_arafo.pdf: 2044562 bytes, checksum: cef64f9c8b79fc9e1bd9e092f4b40fb3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou por meio do espectrofotômetro de reflectância Vita Easyshade® a correspondência de cor entre 3 escalas de referência [Vita Lumin Vacuum (Vita Classical), Vitapan 3D-Master e Chromascop] – Experimento 1, e a correspondência de cor de 2 resinas compostas (4 Seasons® e FiltekTM Supreme XT), nas tonalidades A2E e B2E, em relação a essas 3 escalas de referência por diferirem em sua composição – Experimento 2. Foram confeccionados 5 corpos-de-prova com dimensões de 8 mm de diâmetro e 10 diferentes espessuras (0,2 a 2,0 mm) fotoativados pelo aparelho LED Ultrablue (440 mW/cm2). Em cada amostra foram realizadas 3 mensurações de cor e os valores de diferença de tonalidade (ΔE) obtidos, analisados por regressão quadrática. Os resultados do experimento 1 demonstraram que: houve pouca correspondência de cor entre as tonalidades das 3 escalas avaliadas; no experimento 2, a resina composta nano-aglomerada (FiltekTM Supreme XT) apresentou maior correspondência de cor com as 3 escalas de referência analisadas, quando comparada à resina 4 Seasons®; não houve correspondência de cor entre as resinas compostas avaliadas; as espessuras de resinas compostas que apresentaram maior correspondência de cor com todas as escalas estudadas foram: 1,0; 1,2; 1,4; 1,6; 1,8 e 2,0 mm. Porém, estes corpos-de-prova apresentaram correspondência com a cor de referência (A2E e B2E) e também com outras diferentes tonalidades, demonstrando baixa relação direta entre a cor da escala e a do material restaurador. Concluiu-se de acordo com os resultados que: 1) As escalas de cor Vita Classical, Vitapan 3D-Master e Chromascop não apresentaram correspondência entre suas tonalidades, demonstrando apenas semelhança variada entre si; 2) Composição e propriedades ópticas interferem na correspondência de cor entre... / This study evaluated by the spectrophotometer Vita Easyshade®/Vita, the color correspondence among three shade guides [Vita Lumin Vacuum (Vita Classical), Vitapan 3D-Master/Vita e Chromascop/Ivoclar Vivadent] – experiment 1, and the color correspondence of two composite resins (4 Seasons® and FiltekTM Supreme XT) in the colors A2E and B2E with these three shade guides, for they differ in its composition – experiment 2. Five specimens were made with 8.0 mm in diameter and 10 different thickness (0.2 to 2.0 mm) and light polymerized by LED Ultrablue (440 mW/cm2). The color of specimens were measured 3 times and the values of color difference (ΔE) were obtained, analyzed by analysis of quadratic regression. The results of experiment 1 demonstrated that: there were a little color correspondence among three shade guides; in the experiment 2, the composite resin (FiltekTM Supreme XT) presented higher color correspondence in 3 shade guides than the composite resin 4 Seasons®, there wasn’t color matching between the composite resins analysed; the composite resin thickness that presented larger color correspondence with all shade guides evaluated were: 1.0; 1.2; 1.4; 1.6; 1.8 e 2.0 mm. However, these specimens presented correspondence with the reference color (A2E and B2E) and also with other different shades, showing low direct relationship among the color of the shade guides and of the restoring material. It could be concluded that: 1) The shade guides Vita Classical, Vitapan 3D-Master e Chromascop did’nt presented correspondence among its shades, just demonstrating likeness varied to each other; 2) Composition and optical properties ópticas interfere in the color correspondence between composite resins 4 Seasons® e FiltekTM Supreme XT; 3) The composite resin nanoclusters FiltekTM Supreme XT presented larger color... (Complete abstract click electronic access below)
583

Cimento de ionômero de vidro é melhor do que resina composta em restaurações classe II de dentes decíduos? Uma revisão sistemática com meta-análise / Does glass ionomer cement is better than composite resin in class II primary teeth restorations? A systematic review with meta analysis

Dias, Ana Giselle Aguiar [UNESP] 16 December 2016 (has links)
Submitted by ANA GISELLE AGUIAR DIAS (DINTER) null (anagiselle@saolucas.edu.br) on 2017-02-12T16:16:16Z No. of bitstreams: 1 Tese Ana Giselle Aguiar Dias 11 02 2017.pdf: 1417929 bytes, checksum: a2ee9c1b0b9f679f72dc3d9db75e02d7 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-02-13T18:10:46Z (GMT) No. of bitstreams: 1 dias_aga_dr_arafo.pdf: 1417929 bytes, checksum: a2ee9c1b0b9f679f72dc3d9db75e02d7 (MD5) / Made available in DSpace on 2017-02-13T18:10:46Z (GMT). No. of bitstreams: 1 dias_aga_dr_arafo.pdf: 1417929 bytes, checksum: a2ee9c1b0b9f679f72dc3d9db75e02d7 (MD5) Previous issue date: 2016-12-16 / O objetivo do presente estudo foi realizar uma revisão sistemática e meta-análise (MA) sobre o desempenho clínico do cimento de ionômero de vidro (CIV) comparado ao de resina composta (RC) em restaurações classe II em dentes decíduos. Foi realizada uma busca abrangente nas bases PubMeb, Scopus, Web of Science, LILACS-BBO, Cochrane Library, Clinical Trials e OpenGrey, sem restrições de data ou idioma. Foram utilizados termos Mesh, sinônimos e palavras chave, adaptados para cada base de dados. Também foi feita busca manual na lista de referências dos artigos selecionados. Foram incluídos 5 ensaios clínicos controlados e randomizados e 3 estudos clínicos não randomizados, que compararam o desempenho clínico, avaliado pela presença de lesões de cárie secundária, descoloração marginal, adaptação marginal, forma anatômica e retenção e desgaste do material restaurador de restaurações de classe II realizadas com CIV em comparação com restaurações de RC em dentes decíduos. Quinze estudos completos foram lidos na íntegra, dos quais 8 foram incluídos na síntese qualitativa (risco de viés) e quantitativa (meta-análise). A heterogeneidade variou de baixa a moderada nas 12 MAs realizadas dos 8 estudos, com acompanhamento de 6 a 48 meses (38 a 73%), não havendo diferença significativa entre os dois materiais na análise final (overall effect). A diferença de risco (intervalo de confiança 95%; valor de p) entre RC e CIV quanto a falhas foi de -0,03 (-0,11 – 0,05; p= 0,41); quanto a adaptação marginal, -0, 01 (-0,06 – 0,05; p= 0.8); quanto a descoloração marginal, 0,07 (-0,11 – 0, 26; p=0,44), quanto a forma anatômica, 0,00 (-0,04 – 0,05; p= 0,84); e quanto a presença de lesão de cárie secundária foi de 0,07 (0,02 – 0,12; p= 0,01). A diferença de risco geral para o desempenho clínico foi 0,03 (-0,01 – 0,06; p= 0,17). Para todos os parâmetros analisados, a exclusão de um estudo com menos de 24 meses de acompanhamento e dos estudos não randomizados não influenciou no resultado final da MA. Entretanto, os resultados foram significativamente influenciados pelo tipo de CIV (convencional (n=2) ou modificado por resina (n= 6) e tipo de isolamento (absoluto (n=6) ou relativo (n=2)). Concluiu-se que o CIV modificado por resina apresentou desempenho clínico significativamente superior a RC em relação à prevalência de lesões de cárie secundária, enquanto que o CIV convencional se mostrou semelhante à RC para este parâmetro. Quanto à porcentagem de falhas, adaptação marginal, descoloração marginal e forma anatômica, ambos os materiais apresentaram desempenho semelhante, independente do tipo de CIV. Assim, a possibilidade de fotopolimerização, somada às suas propriedades cariostáticas, indicam que o CIV modificado por resina é o material de escolha para restaurações classe II em dentes decíduos.
584

Avaliação da influência do selante de superfície sobre a translucidez de resina composta. Efeito de tempos e soluções /

Rodrigues Neto, Elidio. January 2004 (has links)
Resumo: O presente trabalho teve como objetivo avaliar o efeito do selante de superfície sobre a translucidez da resina composta, em função das soluções e do tempo de imersão. Para isso foram selecionados os seguintes materiais: resina composta Charisma; selante de superfície Fortify; e quatro soluções para imersão, café, Coca-Cola®, chá e Saliva Artificial. Foram confeccionados 8 corpos-de-prova para cada condição experimental, totalizando 64 corpos-de-prova. A partir disso, os mesmos permaneceram imersos em saliva artificial, mantidos em estufa a uma temperatura de 37ºCl 1, e foram retirados da estufa para imersão nas soluções testadas, três vezes ao dia por um período de cinco minutos, e após este período foram lavados em água corrente e novamente imersos em saliva artificial, até o momento determinado para a leitura da translucidez. As leituras foram realizadas em nove níveis: T1 - após a confecção dos corpos-de-prova, T2 - 24 horas após a imersão nas soluções, T3 - 48 horas após, T4 a T9, sendo respectivamente 7, 14, 21, 30, 60 e 90 dias após a imersão. Para a obtenção dos valores de translucidez (em porcentagem) foi utilizado o aparelho "JOUAN". Os resultados obtidos foram submetidos à Análise de Variância e ao Teste de Tukey a 5%. Observou-se que as soluções influenciaram na translucidez dos materiais (p<0,001), sendo que o café apresentou maior ação pigmentante, seguido pelo chá, Coca-Cola® e saliva artificial. Com relação ao tempo notou-se que a partir de T5 houve uma significante alteração (p<0,001) na translucidez da resina até T8. E quanto ao selante o grupo selado apresentou maiores valores de translucidez (p<0,05) do que o grupo não selado. Mediante a metodologia aplicada pode-se concluir que o café foi a solução que promoveu maior alteração de translucidez, a resina composta sofreu alteração significativa... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of the current study was to evaluate the surface sealant effect upon the composite resin translucence, related to different solutions and immersion periods. The following materials were selected: Charisma composite resin; Fortify surface sealant; and four immersion solutions, which are coffee, Coca-Cola®, tea and Artificial Saliva. Eight test specimens were manufactured for each experimental condition, totaling 64 test specimens. All the specimens were immersed in artificial saliva and maintained in a kiln at 37ºCl 1, being then removed for a five-minute immersion period three times a day in the solutions tested, after which they were washed with tap water and immersed in artificial saliva once more until the translucence reading was performed. The readings were performed in nine levels: T1 - after test specimens manufacture, T2 - 24 hours after the immersion in the solutions, T3 - 48 hours after the immersion, T4 to T9, respectively 7, 14, 21, 30, 60 and 90 days after the immersion. In order to achieve translucence scores (in percentage), the appliance "JOUAN" was used. The results obtained were submitted to the Analysis of Variance and to Tukey's test at 5%. It was possible to observe that the solutions influenced on the materials translucence (p<0.001), and that coffee showed the most staining action, followed by tea, Coca-Cola® and artificial saliva. In regard to time, a significant alteration (p<0.001) was noticed in the composite resin from T5 up to T8. Considering the sealant, the sealed group showed higher scores of translucence (p<0.05) than the non-sealed group. According to the methodology applied, it is possible to conclude that coffee was the solution which provided the most intense translucence alteration, the composite resin underwent a significant alteration in translucence after 21 days of... (Complete abstract, click electronic address below). / Orientador: Patrícia Petromilli Nordi Sasso Garcia / Banca: Welingtom Dinelli / Banca: Silmara Aparecida Milori Corona / Coorientador: Regina Guenka Palma Dibb / Mestre
585

Avaliação dos ciclos de polimerização da resina acrílica para base de prótese total /

Kimpara, Estevão Tomomitsu. January 2001 (has links)
Banca: Maria Auxiliadora Junho de Araujo / Banca: Marco Antonio Bottino / Banca: Antonio Muench / Banca: Simonides Consani / Banca: Zlata Victorovna Hvanov / Resumo: No presente trabalho objetivou-se estudar o desempenho de 4 ciclos de polimerização das RAAT: ciclo I - 65°C por 30 min, 50°C por 23h e 30min e 100°C por 1 h; ciclo II - 50°C por 24h e 1 h a 65°C, 30 min para elevar a 100°C e 1 h a 1 00°C, com outros dois, rotineiramente indicados: ciclo III - 9h a 72°C e o ciclo IV - 1 h a 65°C, 30 min para elevar a 100°C e 1 h a 100°C. As observações, para que pudesse ser analisado o desempenho, foram: verificação do monômero residual, alterações de peso e dimensional linear, porosidade e dureza. Os resultados apontaram quanto ao monômero residual, diferenças significantes estatisticamente no fator ciclo; na alteração de peso, o fator armazenagem e a interação entre os fatores ciclo X armazenagem mostraram diferenças estatisticamente significantes; quanto a alteração dimensional linear, diferenças significantes estatisticamente foram observadas para o fator armazenagem; para a dureza não foram verificadas diferenças significantes e as porosidades não foram observadas nos ciclos I e II, no ciclo III em grau mínimo e em quantidade apreciável no ciclo IV / Abstract: In the present work it was studied the behavior of four water bath curing cycles of heat activated acrylic resin considered as long duration (I - 65ºC for 30 min;50ºC for 23h and 30min; and 100º C for 1h; II- 50ºC for 24h and the rapid cycle), compared to the known long time curing cycle (9 hours for 72ºC) and short curing cycle (1 h for 65ºC; 30 min to elevate at 100º C and 1:00 to 100º C). Analysis consisted of observations and verification of the residual monomer, weight alterations, dimensional, dimensional lineal, porosity and hardness to determine material performance. The results pointed out that residual monomer presented statistical significant differences in the factor storage and interaction among the factors cycle X storage for weight alteration; statistical significant differences for the factor storage for lineal dimensional alterations, without significant differences for hardness. Porosity was verified in minimum degree in the cycle III and in appreciable amount in the cycle IV
586

Influência do selante de superfície em propriedades físicas e mecânicas de resinas compostas submetidas a envelhecimentos artificiais /

Catelan, Anderson. January 2009 (has links)
Resumo: O propósito deste estudo foi avaliar a influência do selante de superfície (Biscover LV, Bisco) na microdureza Knoop, rugosidade de superfície e alteração de cor de resinas compostas microhíbridas e nanoparticulada submetidas a envelhecimentos artificiais. Cem espécimes foram confeccionados para cada resina composta, Supreme XT (3M/Espe), Vit-l-escence (Ultradent) e Opallis (FGM). Após 24h, as superfícies das amostras foram polidas e o selante foi aplicado em 50 amostras de cada compósito. A rugosidade de superfície (Ra) foi determinada com um perfilômetro (SJ-400, Mitutoyo) e cut-off de 0,25mm; a microdureza Knoop foi avaliada em um microdurômetro (HMV-2000, Shimadzu), com carga de 50g durante 15s; e a análise cromática inicial foi avaliada de acordo com o sistema CIE L*a*b* em espectrofotômetro de reflexão (UV-2450, Shimadzu). Após as avaliações iniciais, 10 espécimes de cada grupo foram envelhecidos durante 252h em câmara de envelhecimento acelerado de UV (EQUV, Equilam) ou imersos por 4 semanas em uma das três soluções corantes (refrigerante de cola, suco de laranja ou vinho tinto) ou água destilada como controle. Após os envelhecimentos, as propriedades testadas foram re-avaliadas. Os dados de microdureza, rugosidade, alteração de cor foram analisados pela ANOVA e teste de Fischer (α=0,05). Os envelhecimentos artificiais causaram mudanças de cor em todos os grupos e diminuíram os valores de microdureza para todos os materiais, exceto para os compósitos Vit-l-escence e Supreme XT selados, mas não alteraram os valores de rugosidade. O armazenamento em água destilada teve o menor efeito sobre a microdureza e os menores valores de ΔE comparado com os outros processos de envelhecimento (p<0,05). Os materiais selados apresentaram os menores valores de rugosidade e microdureza comparados aos compósitos não selados. Independente do material estudado... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the influence of surface sealant (Biscover LV, Bisco) on the Knoop microhardness, surface roughness and color alteration of microhybrids and nanofilled composite resins submitted to artificial aging. One hundred specimens were made for each of the composite resins; Supreme XT (3M/Espe), Vit-l-escence (Ultradent) and Opallis (FGM). After 24h, the samples' surfaces were polished and sealant was applied to 50 samples of each composite. The surface roughness (Ra) was determined using a perfilometer (SJ-400, Mitutoyo) and cut-off of 0.25mm; the Knoop microhardness was evaluated in a microdurometer (HMV-2000, Shimadzu), with 50g load during 15s; and the initial chromatic analysis was evaluated in accordance with CIE L*a*b* system in reflection spectrophotometer (UV-2450, Shimadzu). After the initial evaluations, 10 specimens of each group were aged during 252h in a UV-accelerated aging chamber (EQUV, Equilam) or immersed for 4 weeks in one of three staining solutions (cola soft drink, orange juice or red wine) or distilled water as control. After aging, the properties tested were reevaluated. The microhardness, surface roughness and color alteration data were analyzed by ANOVA and Fischer's test (α=0.05). The artificial aging caused color changes in all the groups and decreased the microhardness values for all the materials, except for the Vit-l-escence and Supreme XT sealed composites, but had no effect on the roughness values. The storage in distilled water had the least effect on microhardness and resulted in the lowest values of TE compared with other aging processes (p<0.05). The sealed materials presented the lowest values of surface roughness and microhardness compared to the unsealed composites. Regardless of the material studied, the red wine solution demonstrated the highest level of staining (p<0.0001). Intermediate ΔE values were... (Complete abstract click electronic access below) / Orientador: Paulo Henrique dos Santos / Coorientador: André Luiz Fraga Briso / Banca: Renato Herman Sundfeld / Banca: Flávio Henrique Baggio Aguiar / Mestre
587

Síntese e caracterização de novos materiais compósitos orgânicos/inorgânicos, fotopolimerizáveis, para uso em restaurações odontológicas /

Gatti, Alexandre. January 2008 (has links)
Orientador: Sidney José Lima Ribeiro / Banca: Clóvis Augusto Ribeiro / Banca: Welingtom Dinelli / Banca: Wagner Luiz Polito / Banca: Adhemar Colla Ruvolo Filho / Resumo: O presente trabalho de tese envolveu o estudo de formulações e o desenvolvimento de compósitos orgânicos/inorgânicos, fotopolimerizáveis, para uso em odontologia, tomando-se por base formulações comerciais. Estudou-se o efeito do tipo dos monômeros nas propriedades mecânicas e na cinética de polimerização de compósitos experimentais, utilizando-se como fotoiniciador o BAPO (Irgacure 819®), que foi escolhido com base em resultados de fotocalorimetria. O compósito com a maior resistência e módulo flexural foi obtido utilizando-se como monômeros uma mistura de bisfenol A diglicidil éter dimetacrilato (Bis-GMA), trietilenoglicol dimetacrilato (TEGDMA) e uretano dimetacrilato (UDMA), na proporção mássica de 40:40:20, contendo 50% (m/m) de partículas de sílica funcionalizadas. Foram sintetizadas esferas de sílica opalescentes, monodispersas, com tamanho médio de 160 nm, através da metodologia de Stöber. Estas foram funcionalizadas superficialmente com grupos metacrílicos para serem utilizadas como reforço. Posteriormente, foi preparada uma segunda classe de compósitos contendo oxoclusters de zircônio modificados por grupos metacrílicos, sintetizados pela mistura de alcoóxidos de zircônio, em meio alcoólico, e ácido metacrílico, em diferentes proporções molares. A adição de 5% (m/m) do oxocluster formado pela mistura de 1:5 (mol/mol) de n-butóxido de zircônio (em solução de n-butanol) e ácido metacrílico, respectivamente, fez com que a resistência à flexão do polímero puro aumentasse de 62,70 MPa para 129,9 MPa (aumento de 107%) e seu módulo passasse de 1770 MPa para 3260 MPa (aumento de 84,2%). Resultados de Espalhamento de raios X em Baixo Ângulo (SAXS) levaram à identificação dos oxoclusters no meio polimérico com padrões de dispersão bem definidos. Como resultado tecnológico do trabalho de tese foi proposta uma empresa através... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the present thesis is showed the study and development of experimental dental photopolimerizable organic/inorganic composites, based upon commercial formulations. It was studied the influence of the monomers types on the mechanical and kinetical behavior of some experimental composite formulations, using BAPO (Irgacure 819®) as photoinitiator, that was prior chosen through photocalorimetry measurements. The most resistant composite was obtained using as monomers a mixing of bisphenol A diglycidyl ether dimethacrylate (Bis-GMA), triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) in the mass proportion of 40:40:40, containing 50% (w/w) of functionalized silica particles. It was synthesized monodisperse silica spheres, with an average size of 160 nm, through Stöber's methodology. It receives a methacrylic surface treatment to be used as reinforcement. Afterwards, a second group of composites were prepared using as reinforcement methacrylic modified zirconium oxoclusters prepared through the mixing of zirconium alkoxides, in alcoholic medium, and methacrylic acid, in different molar ratios. The addition of 5% (w/w) of the oxocluster synthesized through the mixture of 1:5 (mol/mol) of the zirconium n-butoxide (in n-butanol solution) and methacrylic acid, respectively, in the polymer, makes it flexural strength raises from 62.70 MPa to 129.9 MPa (increase of 107%) and the Young's modulus changes from 1170 MPa to 3260 MPa (increase of 84.2%). Small Angle X ray Scattering (SAXS) measurements allow the identification of the oxoclusters in the polymeric medium with a well defined dispersion pattern. As result of this thesis a company was proposed through the Program of Innovative Research in the Small Company (PIPE) fomented by the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) that is a government foundation which supports the research in the São Paulo State - Brazil. / Doutor
588

Efeito do Eugenol Sobre o Endurecimento de Resinas Acrílicas Ativadas Quimicamente e Efeitos de Possíveis Tratamentos Paliativos / EFFECT OF EUGENOL ON THE HARDENING OF CHEMICALLY-ACTIVATED ACRYLIC RESINS AND EFFECTS OF A POSSIBLE PALLIATIVE TREATMENT

Milton Lazaro Filho 22 August 2000 (has links)
Foram confeccionados corpos-de-prova para testar a resistência flexural (MF), para testar a sorção de água (Wsp) e material solúvel (Ws) em resina quimicamente ativada (RAAQ), baseados nas especificações no 12 da ADA e ISO 1567 utilizando matrizes especiais à temperatura de 37±1oC. Os espécimes foram preparados em contato com um papel contaminado ou não com 20 mg de eugenol e em cinco condições de tratamento superficial: controle (C), Vaselina (V), PanOxyl 10% (P), PanOxyl 10% + DMT (P10D) e PanOxyl 20% + DMT (P20D). Foram utilizados dois tipos de monômero: MMA, como fornecido pelo fabricante, e com EGDMA. O teste de resistência flexural foi aplicado aos 30 minutos ou com 50 horas a partir do início da mistura. A análise de Wsp e Ws foi aplicada sobre espécimes com 7 dias. A análise dos resultados mostrou que a presença do eugenol afetou a polimerização das RAAQ quando não se utilizou nenhum tratamento paliativo, resultando em queda significativa do módulo flexural aos 30 minutos, enquanto que para a idade de 50 horas, houve apenas uma tendência de diminuição dos valores de módulo flexural. O eugenol, provocou uma diminuição significativa da sorção de água, aumentando porém a solubilidade dos espécimes. Os tratamentos superficiais P10D e P20D aplicados durante a polimerização da resina, conseguiram reverter os efeitos negativos da presença do eugenol sobre o módulo flexural, independentemente da presença do agente de ligação cruzada no monômero. Nesses casos, a sorção de água e solubilização não são afetadas significativamente quando comparadas com os espécimes controle. O tratamento com vaselina provocou uma diminuição significativa do módulo flexural independentemente da idade ou presença de EGDMA, embora não tenha aumentado a sorção de água, nem a solubilidade da resina quando o EGDMA esteve presente. Na ausência de EGDMA, este tratamento aumentou a solubilidade. O tratamento P10 apresentou um comportamento pouco seguro, uma vez que não conseguiu anular os efeitos da presença do eugenol em todas as propriedades e situações estudadas, provocando ainda, uma queda significativa do módulo flexural na idade de 50 horas. / Specimens for flexural strength test (FS), water sorption test (Wsp) and soluble matter test (Ws) were built using a chemically-activated acrylic resin, according to ADA\'s no 12 and ISO 1567 specifications. Using a metallic mould under room temperature of 37±1oC, specimens were prepared with the mould placed on contaminated paper slab or not by 20 mg of eugenol. Five experimental conditions were tested: control (C), petrolatum (P), PanOxyl 10% (P10), PanOxyl 10% + DMT (P10D), PanOxyl 20% + DMT (P20D). Two types of monomer were tested: MMA as supplied by manufacturer and MMA + EGDMA. Flexural test was performed at 30 minutes or at 50 hours, after resin manipulation start. The Wsp and Ws analyses were performed after 7 days. The results showed that eugenol significantly reduced the FS at 30 minutes. At 50 hours, only a trend of decrease was found. The presence of eugenol reduced the water sorption and increased the solubility of the specimens. P10D and P20D applied during polymerization reverted the negative effect of eugenol on FS, regardless of the presence of the crosslinking agent. Wsp and Ws were not significantly altered. Petrolatum application reduced FS significantly, regardless of the storage time or the presence of EGDMA. Nevertheless when EGDMA was present, the petrolatum did not interfere with Wsp and Ws. In the absence of EGDMA, petrolatum increased resin solubility. Treatment with P10 was not reliable, because it was not effective for all the properties studied and, moreover, it led to a significant decrease in FS at 50 hours.
589

Desgaste abrasivo da resina composta Filtek Z250 (4 diferentes cores, fotopolimerizadas por 3 diferentes tempos), através do método do disco retificado / Abrasive wear of Filtek Z250 composite resin (4 different colors, light-cured by 3 different times) through the retified disc method.

Márcia Furtado Antunes de Freitas 24 May 2007 (has links)
O objetivo neste trabalho foi avaliar a influência da variação do tempo de fotopolimerização para diferentes cores (I, B1, B3 e C4) de uma resina composta (FiltekTM Z250, da 3M ESPE), sobre a taxa de desgaste abrasivo através do método do disco retificado. Cada espécime de resina composta fotopolimerizada estava contido numa cavidade semicircular localizada na periferia de um disco constituído por polimetilmetacrilato (PMMA), denominado disco estático, sendo que a superfície curva da resina no disco sofria desgaste por um rebolo de porcelana, denominado tecnicamente de disco dinâmico, sob carga padronizada e velocidade controlada, criando no espécime uma cavidade de aspecto semicircular. O deslocamento vertical do disco estático, ao ser desgastado, era detectado por um palpador, o qual transferia estes dados a um computador e criava os arquivos de desgaste, em função do tempo. Os dados obtidos foram tratados estatisticamente. Pôde-se concluir que 1) a resistência à abrasão do PMMA foi a maior de todas e 2) a resina de cor C4, a mais resistente de todas. / The aim at this study was estimate the influence of light-curing time variation of different colors (I, B1, B3 and C4) of composite resin (FiltekTM Z250, 3M ESPE), upon abrasive wear through the retified disc method. The porcelain existent in the named dynamic disc promoted a wear of each resin specimen located in the polimethylmetacrylate (PMMA) static disc, under a standardized charge and with controlled velocity. Vertical displacement of static disc was detected by a sensor that send data to a computer where wear arquives were plotted in function of time. After data statistical analysis, it could be concluded that: 1) PMMA resistance was greater than anyone of resins and 2) C4 was more resistant than all the other colors.
590

Microinfiltração cervical imediata de dois sistemas adesivos em restaurações ocluso-proximais de resina composta em molares decíduos : estudo in vitro

Brayner, Rosângela Gomes January 2001 (has links)
O objetivo deste estudo foi de avaliar in vitro a microinfiltração cervical imediata em restaurações ocluso-proximais de resina composta, onde foram utilizados dois sistemas adesivos (Scotchbond Multi Purpose - 3M; Clearfil Mega Bond - Kuraray) através de uma técnica de baixa intensidade de luz polimerizável. Em cada um dos 11 molares decíduos foram confeccionados dois preparos cavitários ocluso-proximais padronizados (um ocluso-mesial e outro ocluso-distal), com o auxílio de uma ponta diamantada cilíndrica de extremidade plana n°2094, (KG Sorensen), fixada a uma caneta de alta rotação sob refrigeração ar/água. Os sistemas adesivos foram aplicados seguindo as instruções do fabricante, um na cavidade ocluso-mesial e outro na ocluso distal, sendo inserida, posteriormente, uma resina composta híbrida (Z250 - 3M) pela técnica incremental LUTZ (1986). O primeiro incremento foi inserido na parede cervical da caixa proximal (sentido horizontal) e fotopolimerizado (fotopolimerizador VIPTM - Bisco) a uma intensidade de 100 mW/cm2 por 60 segundos. Dois outros incrementos foram inseridos diagonalmente na porção vestibular e lingual/palatina, a uma intensidade de 200 mW/cm2, também pelo tempo de 60 segundos. As restaurações foram submetidas a acabamento e polimento com o auxílio de um bisturi lâmina n°12 e com discos Sof-lex Pop-on (3M). Após o acabamento, foi realizada a impermeabilização, em seguida os dentes foram imersos em solução azul de metileno a 0,5% por um período de 24 horas, sendo posteriormente seccionados longitudinalmente no sentido mésio-distal para avaliação da penetração do corante, usando para tal o estereo-microscópio. Os resultados foram submetidos à análise estatística através dos testes Qui-quadrado e o teste não-paramétrico U de Mann-Whitney. Os resultados demonstraram não haver diferença estatisticamente significante entre os dois sistemas adesivos testados, podendo-se concluir que a utilização deste protocolo restaurador de cavidades ocluso-proximais com resina composta em molares decíduos resultou em baixos níveis de microinfiltração cervical imediata.

Page generated in 0.0376 seconds