• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 2
  • 2
  • 1
  • Tagged with
  • 36
  • 36
  • 26
  • 16
  • 16
  • 15
  • 13
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Radiografia digital e a tecnica de subtração no monitoramento da desmineralização e remineralização do esmalte dentario / Digital radiography and the subtraction technique for monitoring dental enamel demineralization and remineralization

Bittar-Cortez, Juliana Araujo 25 January 2008 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T07:50:35Z (GMT). No. of bitstreams: 1 Bittar-Cortez_JulianaAraujo_D.pdf: 5858192 bytes, checksum: 3d3d3c7dbc08b34e4b7c483e7316bd88 (MD5) Previous issue date: 2008 / Resumo: O objetivo deste estudo in vitro foi comparar dois protocolos de remineralização em lesões de cárie no esmalte dentário, avaliados por meio de análises de cálcio (Ca) e fósforo (Pi), dureza do esmalte, microscopia de luz polarizada e subtração radiográfica digital (SRD); avaliar a viabilidade da utilização de dois diferentes sistemas de radiografias digitais, placa PSP (photostimulable storage phosphor) e sensor CMOS (complementary metal oxide semicondutor), no diagnóstico de desmineralizações, e a acurácia das radiografias digitais convencionais (RDC) e três métodos de SRD (linear, avançada e logarítmica) no diagnóstico de mudanças minerais; e comparar o ruído e reprodutibilidade das imagens de SRD lineares e logarítmicas produzidas a partir de dois sistemas de radiografias digitais. Para isso, lesões de cárie artificiais foram criadas em 100 superfícies proximais de dentes hígidos. Vinte dentes foram mantidos como controle e oitenta foram submetidos a dois diferentes protocolos de remineralização em 4 e 8 semanas, com a contínua imersão em saliva artificial e um tratamento adicional com flúor. Radiografias digitais foram realizadas antes e depois dos protocolos de remineralização. Cinco examinadores avaliaram a desmineralização e as mudanças minerais nas RDC, dispostas lado a lado, e três métodos da SRD. As análises de Ca / Pi e a colocação dos dentes na solução remineralizante foram considerados como padrão ouro. A média dos tons de cinza e o desvio padrão (DP) no histograma foram também mensurados. As concentrações de Ca e Pi na saliva artificial após os tratamentos foram significativamente menores do que a solução original (p<0,05); e por meio da SRD foi possível verificar diferenças entre as imagens. Entretanto, o teste de dureza e a microscopia de luz polarizada não detectaram nenhuma alteração. O sistema CMOS foi significativamente mais acurado do que a sistema PSP no diagnóstico da desmineralização e mudanças minerais, assim como a SRD linear no diagnóstico de mudanças minerais. Também foram estatisticamente diferentes os valores da média dos níveis de cinza e do DP entre os dois sistemas. Foi concluído que (a) o tratamento adicional de flúor promoveu valores maiores de ganho mineral; (b) a análise de Ca / Pi na saliva artificial foi o método mais sensível na avaliação de alteração mineral; (c) a imagem de SRD linear é um método válido na detecção do aumento de intensidade, como sinal de ganho mineral; e (d) as imagens de SRD utilizando as placas PSP tiveram um menor ruído do que nas imagens geradas pelo sensor CMOS / Abstract: The aim of this in vitro study was to compare two remineralization protocols of artificial carious lesions in enamel, evaluated by Calcium (Ca) and Phosphorus (Pi) analysis, cross-section hardness test, polarized light microscopy and digital subtraction images (DSR); to assess the feasibility of using two different systems of digital radiography, photostimulable storage phosphor (PSP) plate and complementary metal oxide semiconductor (CMOS) sensor on the demineralization diagnosis, and the accuracy of digital conventional radiographs (DCR) and three methods of DSI (linear, advanced and logarithmic) on mineral changes diagnosis; and, to compare noise and reproducibility in linear and logarithmic DSI produced from two digital radiography systems. Artificial caries-like lesions on 100 approximal surfaces of sound teeth were produced. Twenty teeth were kept as control and eighty teeth were subjected to two different remineralization protocols for 4 and 8 weeks, with continuous immersion in artificial saliva, and additional fluoride treatment. Digital radiographs were taken before and after the remineralization protocols. Five examiners assessed demineralization and mineral changes on DCR, placed side by side, and three methods of DSI. Ca / Pi analysis and the placement of the teeth on the remineralization solution was the gold standard. The mean shades of gray and the standard deviation (SD) of the histogram were also assessed. The concentrations of Ca and Pi in the artificial saliva after the treatments were significantly lower than the original solution (p<0.05); and DSR showed differences between the images. However, the Hardness test and polarized light microscopy did not detect any changes. CMOS system was significantly more accurate than PSP system on demineralization and mineral changes diagnosis, and also linear DSR on mineral changes diagnosis. It was also statistically significant different the values of mean shades of gray and SD between both systems. It was concluded that (a) the additional Fluoride treatment provided higher values of mineral gained; (b) Ca / Pi analysis in the artificial saliva were the most sensitive method of mineral change evaluation; (c) linear DSI is a valuable method to disclose an intensity increase, as a sign of mineral gained; and (d) DSR images created from PSP plates had less noise than images produced from CMOS sensor / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
22

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.
23

Experimental Evaluations of ESF Methods For Neutron Radiographic Image Analysis

Butler, Michael Paul January 1980 (has links)
<p> Some experiments designed to test the validity of the edge-spread function (ESF) model for neutron radiographic image formation are described; in addition the experiments are meant to illustrate the application of ESF methods to two areas of practical concern. First, the prediction of optical density curves for specified material and geometric configurations is considered; then, the use of ESF methods in dimensioning irradiated reactor fuel elements is examined. Overall, the results indicate that within the framework of assumptions which ESF theory is based upon, the correlation between theory and experiment is excellent. The results also suggest that in situations which deviate from the theoretical ideal, the ESF method may serve as a good first approximation to more complex models. </p> / Thesis / Master of Engineering (ME)
24

Método computacional automático para correção do efeito \"heel\" nas imagens radiográficas / An automatic computational method for correction of the heel effect in radiographic images

Nascimento, Marcelo Zanchetta do 18 March 2005 (has links)
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito \"heel\". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito \"heel\". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito \"heel\" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD. / The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
25

Calculation of scatter in cone beam CT : steps towards a virtual tomograph /

Malusek, Alexandr, January 2008 (has links)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2008. / Härtill 5 uppsatser.
26

Evaluation of dose and image quality parameters for cone-beam CT localization protocols in radiation therapy

Jacome, Victor Roland. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 152-154.
27

Optimization of image quality and minimization of radiation dose for chest computed radiography

Kong, Xiang. January 2006 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 69-70.
28

Análise densitométrica digital do processo de reparo em dentes de rato reimplantados

Giovanini, Ellen Greves [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T20:13:38Z : No. of bitstreams: 1 giovanini_eg_me_araca.pdf: 1544057 bytes, checksum: 1b518f21ba8bc63249a3f29eb78ba402 (MD5) / A avulsão dentária é caracterizada pelo completo deslocamento do dente do seu alvéolo e a melhor forma de tratar um dente avulsionado é o seu reimplante. Mesmo diante das melhores circunstâncias os reimplantes tardios falham devido à reabsorção radicular que é detectada apenas durante a avaliação radiográfica. A imagem digital surgiu como um recurso diagnóstico rápido e de fácil utilização sendo considerada precisa. Para diminuir a variabilidade de interpretação é sugerida a análise radiográfica quantitativa por meio da densidade radiográfica. O propósito deste trabalho foi analisar comparativamente o processo de reparo do reimplante dental em ratos utilizando a análise densitométrica no sistema digital Digora. Foram utilizados 30 ratos machos, divididos em 3 grupos de 10 animais, que tiveram seu incisivo superior direito extraído e tratado da seguinte forma: grupo I - reimplante imediato, grupo II - reimplante tardio sem tratamento e o grupo III - reimplante tardio com tratamento da superfície radicular utilizando raspagem do ligamento e fluoreto de sódio. Os animais foram sacrificados após 60 dias do ato operatório, suas maxilas foram separadas e as imagens radiográficas obtidas de forma que sobre cada placa óptica ficassem as duas hemimaxilas (tratada e controle), o penetrômetro de alumínio e a identificação. Foram realizadas medidas de densidade em áreas padronizadas no sistema Digora. Os valores densitométricos encontrados foram submetidos à análise de variância e teste de Tuckey, e análise não paramétrica do número de áreas de reabsorção. Podemos concluir que a análise densitométrica constitui um importante exame complementar para o acompanhamento dos reimplantes uma vez que permitiu a detecção de reabsorção radicular em todos os grupos, cuja ordem decrescente de envolvimento foi o grupo do reimplante tardio sem tratamento... / The dental replanted has been considered the best treatment of the tooth avulsion, which is characterized by complete alveolar dislodgment of the tooth. Despite of the adequate clinical situations, the delayed replantation fails due to the root resorption that is detected during the radiographic evaluation. The use of the digital image represent a fast and easy diagnostic resource, furthest more precise. The quantitative radiographic analysis has been suggested to reduce the interpretation variability through the radiographic density. The purpose of this work was to analyze the process of repair of the dental replanted using the digital densitometry in the Digora system. The 30 male rats were divided in 3 groups of 10 animals, and their right superior incisor were extracted and treated agreement with their group: group I - immediate replanted, group II - delayed replanted without treatment and the group III - delayed replanted with treatment of the root surface using fluoride of sodium. The animals were sacrificed after 60 days operative act, your jawbones were separate and the radiographic images obtained so that on each optical plate were the two jawbones (treated and control), the aluminum step wedge and the identification. The radiographic density of radicular standardized area in Digora system was measured. The densitometric values were submitted to the variance analysis and test of Tuckey and analysis non parametric of the number of areas root resoption. We can end that digital densitometry analysis it an important complementary for replanted evaluation once it allowed the detection of root reabsorption in all of the groups, whose decreasing order of involvement was the group of the delayed replanted without treatment, following for the delayed replanted with treatment and last the immediate replanted.
29

Método computacional automático para correção do efeito \"heel\" nas imagens radiográficas / An automatic computational method for correction of the heel effect in radiographic images

Marcelo Zanchetta do Nascimento 18 March 2005 (has links)
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito \"heel\". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito \"heel\". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito \"heel\" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD. / The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
30

Exatidão de filtros de imagem na avaliação radiográfica do nível ósseo peri-implantar / Accuracy of enhancement filters in measuring in-vitro periimplant bone level

Vaz, Sergio Lins de Azevedo, 1984- 20 August 2018 (has links)
Orientador: Paulo Sérgio Flores Campos / Texto do capítulo 1 em inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T12:07:20Z (GMT). No. of bitstreams: 1 Vaz_SergioLinsdeAzevedo_M.pdf: 1201820 bytes, checksum: c01a9a7bcc2ca60b934986c91f46e192 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste trabalho foi identificar a exatidão de alguns filtros de imagem na mensuração do nível ósseo peri-implantar, por meio da radiografia digital. Para isso, vinte implantes de titânio (Titamax, Neodent, Curitiba, PR, Brasil) foram instalados em seis fragmentos de costelas bovinas, nas quais foram criados defeitos do tipo perda óssea. Utilizando um sistema intra-bucal de placas de fósforo (Vista Scan, Dürr Dental, Beitigheim-Bissingen, Alemanha), radiografias periapicais foram realizadas posicionando os implantes segundo a técnica do paralelismo. Após a obtenção das imagens, nove filtros do software DBSWIN foram aplicados: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss e sculpture. Um avaliador mensurou as distâncias entre o ombro do implante à porção mais apical do defeito no software Image J. Os defeitos também foram mensurados nas costelas bovinas utilizando um paquímetro digital. O teste não-paramétrico de Friedman comparou os valores obtidos nas imagens com aplicação dos filtros aos encontrados nas imagens originais e nas costelas bovinas, adotando nível de significância de 5%. Os resultados mostraram diferenças estatisticamente significantes para os filtros caries1, caries2, endo e perio (P < 0.05) tanto em relação às imagens originais, quanto em relação às mensurações obtidas com o paquímetro. As mensurações obtidas com as imagens originais, filtros fine e emboss foram mais próximas às obtidas com o paquímetro. Concluiu-se que os filtros fine e emboss foram os mais exatos na mensuração do nível ósseo peri-implantar, sendo equiparáveis às imagens originais. Os filtros caries1, caries2, endo e perio foram os menos exatos, não sendo indicados para este fim / Abstract: This study aimed to identify the accuracy of some enhancement filters of an intraoral phosphor-plate system for measuring the simulated periimplant bone level. Twenty titanium implants (Titamax, Neodent, Curitiba, PR, Brazil) were placed into six fragments of bovine ribs and defects simulating bone loss were created. Periapical radiographs were taken with a phosphor-plate system (Vista Scan, Dürr Dental, Beitigheim-Bissingen, Germany) according to the paralleling standard technique, and nine enhancement filters were applied: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss and sculpture. An oral radiologist measured on the Image J software the distance from the neck of the implant to the most apical contact of the bone with the implant. The Friedman non-parametric test compared the radiographic measurements to those obtained on the bovine ribs with a digital caliper. The significance level adopted was 5%. The caries1, caries2, endo, and perio filters resulted on measurements statistically different from both the original images and the measures of the digital caliper (P < 0.05). In conclusion, the fine and emboss filters resulted on the most precise filters, with similar measures to the original images. The caries1, caries2, endo, and perio filters were the less accurate for measuring the periimplant bone level / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Page generated in 0.4358 seconds