• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 614
  • 24
  • 10
  • 7
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 670
  • 424
  • 152
  • 94
  • 89
  • 87
  • 86
  • 82
  • 66
  • 66
  • 65
  • 62
  • 59
  • 59
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Radioterapia

Carvalho, António Pedro Ferreira de January 1921 (has links)
No description available.
2

Generalidades sobre a curietherapia do cancro

Pinto, João Victor de Macedo January 1925 (has links)
No description available.
3

Desenvolvimento e avaliação de um sistema de cálculo de dose independente para controle de qualidade de IMRT do tipo jaws-only

Silva, Luis Felipe Oliveira e 30 October 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-06-06T17:55:07Z No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-06-15T11:30:22Z (GMT) No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5) / Made available in DSpace on 2016-06-15T11:30:22Z (GMT). No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5) / A radioterapia de intensidade modulada (IMRT, do inglês intensitymodulatedradiotherapy) proporciona distribuições de dose bastante complexas, com regiões de alto gradiente de dose. Essa complexidade representa um desafio maior no controle de qualidade (CQ) quando se compara a IMRT com a radioterapia convencional. O objetivo do presente trabalho foi desenvolver e avaliar um sistema de cálculo de dose independente, chamado SCI, para o controle de qualidade da IMRT do tipojawsonly. O software desenvolvido utiliza um algoritmo de cálculo de dose baseado em correções realizadas no fator de calibração do acelerador linear, por meio de fatores tabelados, derivados de medições e calculados a partir de simples modelagem. Os próprios dados gerados no comissionamento são usados para alimentar o algoritmo.Os cálculos são realizados em um plano de um fantoma retangular. Para validar o SCI, comparações entre as previsões dosimétricas do sistema e outras referências foram realizadas. Foram comparados: doses pontuais no centro de campos assimétricos medidos com câmara de ionização; perfis de campos medidos com filme radiocrômico e com câmara de ionização; distribuições planares de dose de cinco casos de câncer de próstata e cinco de cabeça e pescoço medidas com um arranjo bidimensional de câmaras de ionização e calculadas pelo sistema de planejamento de tratamento (SPT). A avaliação foi realizada utilizando diferenças percentuais de dose, a menor diferença de posição em que se encontra o mesmo valor de dose (DTA, do inglês distancetoagreement) e a avaliação gama com critérios: (i) diferença máxima de dose de 3%, DTA de 3 mm; (ii) diferença máxima de dose 5%, DTA de 3 mm; e (iii) diferença máxima de dose 5%, DTA de 5 mm. As diferenças encontradas nas comparações entre as doses obtidas no centro de campos assimétricos foram menores do que 2,5%.As diferenças nos perfis dos campos quadrados menores do que 30x30 cm2 foram menores do que 2% ou 2mm. Os campos menores, medidos com filme, apresentaram diferenças mais consideráveis (DTAs de até 5 mm foram observadas). Esse resultado já era esperado devido à maior resolução espacial do filme quando comparada à da câmara de ionização (volume sensível de 0,125 cc). As avaliações gama usando tanto as medições quanto o SPT como referência sugerem que o SCI representa a distribuição de dose real segundo o critério de 5% de diferença máxima de dose e 5 mm de DTA, uma vez que a média de pontos aprovados foi superior a 96,5% (p<0,001) em todos os casos quando esse critério foi utilizado. O sistema também apresenta um boa representação segundo o critério de 5% de diferença máxima de dose e 3 mm de DTA (média de pontos aprovados superior a 92,0%; p<0,01). As médias de pontos aprovados com esses dois critérios estão, portanto, de acordo com os valores tipicamente usados como referência por profissionais da área de radioterapia. Desta forma, o sistema desenvolvido no presente trabalho está pronto para ser utilizado para o CQ de IMRT do tipo jawsonly sem custo adicional em relação aos equipamentos já utilizados, reduzindo o fluxo de trabalho comparado a métodos mais tradicionais e sem ocupação adicional da máquina de tratamento. / Intensity modulated radiation therapy (IMRT) provides complex dose distributions with high dose gradient regions. This complexity is a major challenge for quality assurance (QA), specially when comparing IMRT with conventional radiotherapy. In this research, I propose, develop, and evaluate an independent dose calculation system for QA of jaws only IMRT (JOIMRT). The developed software uses a dose calculation algorithm based on corrections performed over the linear accelerator (linac) calibration factor. In order to perform this corrections I used tabulated factors derived from measurements and calculated from simple modeling. Also, I used the linac's commissioning data as input to the algorithm.The developed system then performs the main computations over a rectangular phantom plan. To validate the proposed system, I compared the predictions of the dosimetric system with references that are commonly used in the literature. Specifically, I compared: point doses in the center of asymmetric field measured with an ionization chamber; dose profiles measured with radiochromic film and an ionization chamber; planar dose distributions of five of prostate and five head and neck cases measured with a two-dimensional array of ionization chambers and calculated by the treatment planning system (TPS). The evaluation was performed using percentage dose differences, distance to agreement (DTA) and gamma evaluation with tree criterions: (i) maximum difference dose of 3% and 3 mm DTA, (ii) maximum difference dose of 5% and 3 mm DTA, and (iii) maximum difference dose of 5% and 5 mm DTA. The differences in the comparisons between the doses obtained in the center of asymmetric fields were smaller than 2.5%. Differences in the profiles of square fields up to 30x30 cm2 were smaller than 2% or 2 mm. Smaller fields measured with film showed more significant differences (I measured DTAs up to 5 mm). This result was expected because of the higher spatial resolution of the film, as compared to the ionization chamber that provided the measurements used as inputs to the calculation algorithm (sensitive volume of 0.125 cc). The point approval ratings using both measurements and the TPS as a reference suggest that the independent dose calculation system represents the actual dose distribution according to the criterion of 5 % maximum dose difference and 5 mm DTA, since the average was approved points above 96.5% (<0,001) in all cases when this criterion was used. The system also features a good representation according to the criterion of 5% maximal dose difference and 3 mm DTA (average of approved points above 92.0%; p <0.01). Therefore, the average of approved points obtained with those two criteria satisfies the values typically used as references by radiotherapy professionals. In this way, the system I developed is ready to be used for the JOIMRT QA with no additional cost with respect to equipment already used, reducing the workload compared to more traditional methods and without additional treatment machine occupation.
4

Factores asociados a disfunción sexual durante periodo post tratamiento en mujeres con diagnóstico previo de cáncer cervicouterino en el Instituto Nacional de Enfermedades Neoplásicas (INEN) hasta diciembre del año 2020

Chávez Quispe, Daniela Carolina, Ybáñez Gómez, Romina Betsabé 25 November 2020 (has links)
La calidad de vida es un concepto que puede enfocarse desde un punto de vista individual y comunitario, el cual se vincula con el bienestar social de cada persona. En el ámbito de la salud, la calidad de vida se caracteriza por ser multifactorial y por relacionarse con el estado funcional y el estado de salud de los pacientes. Dentro de los diversos factores de la calidad de vida, se hace mención del funcionamiento sexual e imagen corporal. La función sexual es un componente del funcionamiento humano, el cual radica en un conjunto de características físicas y psicológicas. Se ha visto que, si la disfunción sexual es afectada, de igual manera ocurrirá en la calidad de vida. Las enfermedades crónicas son quienes desarrollan un mayor impacto en la vida de una persona y podrían considerarse como una de las principales causantes de alteraciones en la calidad de vida. Este tipo de enfermedades repercuten sobre diferentes aspectos relacionados con la autoestima, la autovaloración y la autoimagen; en consecuencia, suelen aparecer síntomas depresivos. Entre las enfermedades crónicas, es el cáncer quien ocupa el segundo lugar como causa de muerte a nivel mundial con 1,3 millones de muertes. En el Perú, el cáncer cervicouterino es considerado como una de las principales neoplasias que mayor afecta a las mujeres peruanas; es más, el diagnostico suele ser tardío y provoca que el tratamiento sea más degenerativo e invasivo, como lo son la radioterapia y la quimiorradioterapia, quienes podrían relacionarse con la disfunción sexual.
5

Comparación del tratamiento local entre radioterapia intraoperatoria (RIO) y radioterapia externa (RE) convencional luego de cirugía de conservación del cáncer de mama temprano durante los años 2016-2018 en una clínica privada oncológica, Lima-Perú

Delgado Villaverde, Sandra, Lachira-Yparraguirre, Lizbeth 31 July 2020 (has links)
Objetivo: Comparar la incidencia de recurrencia local ipsilateral, toxicidad y supervivencia en pacientes con cáncer de mama temprano, que fueron sometidas a Radioterapia intraoperatoria (RIO) o a radioterapia externa (RE) convencional adyuvante a la cirugía de conservación durante los años 2016-2018 en una clínica privada oncológica, Lima-Perú. Diseño: Proponemos realizar un estudio observacional, analítico de cohortes retrospectivo. Los estudios de cohortes retrospectivos han sido usados para evaluar efectividad de algunos tratamientos a nivel poblacional, complementando la información extraída de ensayos clínicos (EC) randomizados a nivel individual (32,33). Estos estudios siguen a los pacientes en su centro de atención (prospectivos), u obtienen la información de una base de datos clínica (retrospectivos). Los resultados obtenidos son extrapolables a la población clínica de procedencia, se obtienen más rápido que en los ensayos clínicos, y permiten establecer comparaciones de resultados para distintos tratamientos. Estas comparaciones sólo se limitan por el número de pacientes en cada subgrupo de análisis (34). Sin embargo, se debe tomar en consideración que al no aleatorizar a nuestra población, no se podría esperar que ambos grupos RIO y RE adyuvante hayan presentado un pronóstico similar al inicio, por lo que los resultados deben ser manejados con cautela y como un paso inicial en la investigación del tema. Ante esta limitación, se propone homogeneizar lo más posible la muestra obtenida de las bases de datos disponibles. Finalmente, Sabin et al señalan que los estudios observacionales de cohortes se están usando cada día más para establecer comparaciones de diferentes estrategias de tratamientos (34).
6

Tratamento conservador do carcinoma mamario : estadios I e II

Monti, Carlos Roberto 07 November 2018 (has links)
Orientador : Luiz Guilhermo Bahamondes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-07T17:29:02Z (GMT). No. of bitstreams: 1 Monti_CarlosRoberto_D.pdf: 2200563 bytes, checksum: e9abbe654004fb1865b64a6dd900880b (MD5) Previous issue date: 1990 / Resumo: Durante o período de 1981 a 1988, 265 pacientes portadoras de carcinoma da mama, estádios clínicos I e II (UICC-1987), foram avaliadas após tratamento conservador com quadrantectomia mais axilectomia, radioterapia e quimioterapia. Após o tratamento cirúrgico, as pacientes receberam terapêutica radioterápica na mama com megavoltagem de Cobalto-60 ou acelerador linear de 4 MeV e na dose total de 5.000 cGy em cinco semanas. Um reforço radioterápico na cicatriz da quadrantectomia com 1.000 cGy em uma semana foi realizado com ortovoltagem. A quimioterapia adjuvante foi realizada em 156 (58,8%) pacientes e com esquema de seis ciclos de CMF em intervalos de 21 dias. O tempo médio do seguimento clínico foi de 42,8 meses, com mínimo de 24 e máximo de 99 meses. Seis (2,3%) pacientes tiveram recidiva local e 48 (18,1%) apresentaram metástases a distância. A sobrevida total em cinco anos foi de 89,8% e a sobrevida livre de doença alcançou 75% no mesmo período. O estudo não revelou diferenças significantes entre os estádios clínicos classificados após a cirurgia, e o uso da quimioterapia adjuvante não influenciou os resultados nos diversos estádios. Estudou-se como variável dependente o tempo decorrido até a recidiva da doença e diversas variáveis independentes, como a idade, estado menstrual, tipo histológico, estádio clínico, estádio histopatológico, grau nuclear, uso da quimioterapia, localização do tumor na mama, recidiva local e o tempo decorrido entre a biópsia e a cirurgia. A variável independente associada mais importante durante toda a análise foi o grau histológico (p < 0,003). Cerca de 60% das pacientes tiveram bons resultados cosméticos / Abstract: From 1981 to 1988, 265 patients with breast cancer stages I and II (UICC-1987), were evaluated after conservative treatment with quadrantectomy plus axillectomy, radiotherapy and chemotherapy. After surgical treatment, the patients were submitted to radiation therapy in the breast, receiving megavoltage with cobalt-60 or 4 Me V linear accelerator and a total dose of 5.000 cGy in 5 weeks. The quadrantectomy scar received an extra dose of 1.000 cGy in 1 week on orthovoltage. One hundred and fifty six (58,8%) patienls were submitted to adjuvant chemotherapy, 6 CMF cycles in a 21-day-interval. The median clinical follow-up period was 42.8 months with a minimum of 24 and a maximum of 99 months. Six (2,3%) patients presented local recurrence and 48 (18,1 %) presented distant metastasis. After five years the total survival rate was 89,7% and the disease free survival rate was 75% in the same period. The study did not show significant differences among the clinical stages classified after surgery and the use of adjuvant chemotherapy did not influence the results of the many stages. The period of time until disease recurrence was considered as a dependent variable, and many independent variables such as: age, menstrual condition, histologic type, clinical stage, histopathologic stage, nuclear grade, use of chemotherapy, breast tumor site, local recurrence and the period between biopsy and surgery. The most important independently linked variable during all the analysis was the histologic grade (p < 0,003). About 60% of the patients had good cosmetic results / Doutorado / Doutor em Ciências Médicas
7

Modelo paramétrico para o controle da geometria física dos feixes de íons pesados nos procedimentos de tratamento de câncer de pulmão / A parametric model for the physical geometry control with heavy ion beams in the procedure of cancer treatment in lungs

Chaves, Priscila January 2008 (has links)
No presente trabalho apresenta-se a hadronterapia no contexto do tratamento de radioterapia, que utiliza feixes de íons pesados. Este último tem uma dose ideal para o tratamento de tumores no interior de órgãos humanos ej ou localizados próximos aos órgãos críticos. Além disso, este tipo de terapia aplica-se aos casos em que não há eficiência da radioterapia convencional com fótons ou elétrons. Os feixes de carbono ou prótons são utilizados não só para melhorar a irradiação do tumor, mas também para reduzir efeitos no tecido saudável adjacente a longo prazo, devido a uma menor deposição de energia. Nesta linha foi desenvolvido um modelo paramétrico para o controle físico da geometria dos feixes de íons pesados, utilizando um modelo em 2D para descrever o pulmão, bem como a anatomia tumoral. Além disso, a parametrização prevê um esquema para a varredura do feixe de partículas em três dimensões, que define a trajetória do feixe durante o processo de irradiação. Também foram realizados cálculos para a deposição de energia das partículas pesadas, ou seja, cálculo da energia liberada pelo feixe de partículas (prótons ou íons de carbono), em função da profundidade na penetração do tumor. Sabe-se que fótons ou elétrons depositam maiores doses enquanto "varrem" o tecido biológico, diferente de íons pesados ou prótons, que mostram uma acentuada deposição de energia no final (pico de Bragg) da trajetória das respectivas partículas, o que minimiza os efeitos destrutivos na região de tecidos saudáveis. Este fato é o argumento essencial para a escolha dessas partículas no tratamento de tumores. O controle geométrico do feixe é implementado por uma parametrização unidimensional, que orienta a partículas na superfície do tumor ou no interior de qualquer superfície definida, sendo este, um grau de liberdade suficiente para direcionar os feixes de íons pesados no acelerador. / In the present work we present hadrontherapy in the context of radiotherapy treat- ment, using heavy ion beams. The latter have an ideal dose for tumor treatment in the interior of human bodies and/or in positions close to critical organs. Further this type of therapy applies to cases where conventional radiotherapy with photons or electrons lacks efficiency. The beams of carbon or protons are used not only to improve the irradiation of the tumor but also to reduce effects in the neighboring healthy tissues in the long term. In this line we developed a parametric model for the physical geometry control of heavy ion beams, using a 2D model in order to describe the lung as well as the tumor anatomy. Further the parameterization provides a scheme for the scanning with the particle beam in planes in three dimensions, which defines the trajectory of the beam during the irradiation process. We also performed calculations for the energy deposit of heavy particles, i.e. we calculated the energy released by the particle beam (protons or carbon ions) as a function of penetration depth in the tumor. It is well known that photons or electrons loose larger doses while entering the biological tissue, differently than heavy ions or protons which show a pronounced energy deposit (the Bragg peak) at the end of the respective particle trajectories, which in turn minimizes the destructive effects in the region of healthy tissues. This fact is the essential argument for choosing those particles for tumor treatment. The geometric control of the beam is implemented by a one dimensional param- eterization, which guides the particles among the surface of the tumor or in any defined interior surface, where one degree of freedom is adequate for directing heavy ion beams in the accelerator arrangement.
8

Avaliação do efeito do laser infravermelho de 780 nm no tecido ósseo submetido à radioterapia- estudo experimental em ratos

Cunha, Samantha Seara da 29 May 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-05-27T17:30:59Z No. of bitstreams: 1 Tese_ODONTO_Samantha Cunha.pdf: 2228434 bytes, checksum: d2bf33eb26ebc041ecd7767439f4088a (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-05-30T00:46:01Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Samantha Cunha.pdf: 2228434 bytes, checksum: d2bf33eb26ebc041ecd7767439f4088a (MD5) / Made available in DSpace on 2013-05-30T00:46:01Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Samantha Cunha.pdf: 2228434 bytes, checksum: d2bf33eb26ebc041ecd7767439f4088a (MD5) / CAPES / O efeito biomodulador do Laser em tecido duro normalmente vascularizado já foi comprovado cientificamente, no entanto seu efeito sobre o tecido ósseo submetido à radioterapia ainda não foi estudado na literatura consultada. O presente estudo teve como finalidade avaliar o efeito da Laserterapia (=780 nm) sobre o tecido ósseo de ratos submetidos à radioterapia. Vinte e dois ratos Wistar foram aleatoriamente divididos em quatro grupos: Grupo I -Controle (n=4), recebeu apenas radioterapia; Grupo II- Laser um dia antes da radioterapia (n=6); Grupo III- Laser logo após a radioterapia (n=6); Grupo IV- Laser quatro semanas após a radioterapia (n=6). A radiação ionizante utilizada teve como fonte o Cobalto 60 e foi aplicado em dose única de 3000 cGy no fêmur. Os grupos experimentais, que foram submetidos ao Laser, receberam sete irradiações com intervalos de 48 h. O Laser foi aplicado em todos os grupos experimentais em quatro pontos com densidade de energia de 100 J/cm2, potência de 40 mW, tempo de 100 segundos, área de spot de 0,04 cm², por sessão. Todos os animais foram sacrificados seis semanas após a radioterapia. Clinicamente foi possível observar erosões cutâneas, iniciadas na sexta semana após a radioterapia, nos animais que receberam Laser (grupos II, III e IV). Radiograficamente observou-se uma quantidade significativamente maior (p<0,05) de tecido ósseo nos grupos II e IV, quando comparado com o grupo controle; o mesmo fato não ocorreu com o grupo III. Histologicamente foi possível observar no tecido ósseo um aumento da celularidade medular, do número de osteócitos e canais de Harvers nos grupos II e IV (p<0,05). Ocorreu ainda um aumento estatisticamente significante da atividade osteoblástica nos grupos II, III e IV (p<0,05). Pode ser concluído com esse estudo que a Laserterapia determinou uma resposta positiva na biomodulação do tecido ósseo irradiado, principalmente quando iniciada antes da radioterapia ou após quatro semanas. A utilização do Laser nos parâmetros acima, no entanto deve ser utilizado com cautela, devido às lesões cutâneas evidenciadas. / Salvador
9

Avaliação do efeito da laserterapia em baixa intensidade na reparação óssea após radioterapia externa – estudo experimental em ratos

Paixão, Darcy de Almeida 09 September 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-09-09T17:09:31Z No. of bitstreams: 1 Tese_ODONTO_Darcy de Almeida.pdf: 3141974 bytes, checksum: 09c37949fd5905f717b7cc5222840f79 (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-09-09T17:34:56Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Darcy de Almeida.pdf: 3141974 bytes, checksum: 09c37949fd5905f717b7cc5222840f79 (MD5) / Made available in DSpace on 2013-09-09T17:34:56Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Darcy de Almeida.pdf: 3141974 bytes, checksum: 09c37949fd5905f717b7cc5222840f79 (MD5) / CAPES / Esse estudo teve como objetivo avaliar o efeito da Laserterapia em baixa intensidade na reparação de feridas cirúrgicas produzidas no tecido ósseo de ratos da raça Wistar. Para isso, foi artificialmente produzido um orifício no fêmur dos ratos e quatro dias após, os ratos foram submetidos a radioterapia externa com fonte de cobalto radioativo na dosagem de 3000 cGys. O grupo experimental recebeu adicionalmente sete sessões de Laserterapia de 780 hm, 40 nW, 100 J/cm2, por 100 seg. (quatro pontos ao redor da ferida cirúrgica) a cada 48 h, iniciadas imediatamente após a cirurgia. Esses animais foram sacrificados em três e cinco semanas. Os resultados foram baseados nas análises clínica, radiográfica digital e histológica. Clinicamente, embora os ratos tenham ganhado massa corporal com o decorrer do experimento (p< 0,05), aqueles submetidos à Laserterapia apresentaram reações inflamatórias cutâneas. Na avaliação radiográfica observou-se que em todos os casos, à exceção do grupo não submetido à Laserterapia e sacrificado em cinco semanas, a média dos níveis de cinza da perna submetida à radioterapia foi menor que a da perna contra-lateral, embora não tenha havido diferença estatística (p> 0,05). Em relação aos achados histológicos, o número de osteócitos (p< 0,0001) e de canais de Harvers (p< 0,0001) foi significativamente maior nos grupos irradiados com Laser, em todos os tempos de sacrifício. Em relação aos osteoblastos, pode-se observar que existiu associação entre sua presença e os grupos submetidos à Laserterapia (p< 0,05). Pode-se concluir então que, com as doses aplicadas e protocolo seguido no presente estudo, a radioterapia determinou reabsorção do tecido ósseo, que tendeu a normalizar com tempo e que Laserterapia aumentou a atividade de remodelação óssea e irrigação sanguínea local, embora tenha provocado reações cutâneas adversas. / Salvador
10

Avaliação das reações agudas da pele e seus fatores de risco em pacientes com câncer de mama submetidas a radioterapia / Evaluation of the acute skin reaction and the risk factors in patients irradiated for breast cancer

Pires, Ana Maria Teixeira [UNIFESP] January 2007 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:47:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2007 / Objetivos: avaliar e classificar as reações de pele segundo os critérios Radiation Therapy Oncology Group (RTOG) e caracterizar fatores que possam interferir nessas reações (incidência e/ou gravidade da reação de pele). Métodos: estudo prospectivo, com 86 mulheres com câncer de mama operadas, estadios iniciais, submetidas à radioterapia adjuvante na Universidade Federal de São Paulo e no Hospital Alemão Oswaldo Cruz. A radioterapia foi realizada em região da mama, campos tangentes e paralelos opostos, dose total de 5040 cGy (180 cGy dose/dia), com Acelerador Linear de 6 MV. Os dados foram coletados conforme instrumento de avaliação e TCLE assinado. Além dos dados pessoais, foi medido o tamanho da mama, a partir do desenho do contorno da mesma. Mediu-se a distância entre a separação dos campos e a altura da mama. A avaliação da pele da área de tratamento foi realizada semanalmente e as reações foram classificadas a partir do RTOG. Resultados: a medida da altura da mama e a técnica de tratamento foram significantes na análise univariada, para incidência de reação de pele grau 3. Porém, apenas a altura da mama foi fator significante na análise multivariada para a gravidade da reação de pele. Observamos que a chance de ocorrer reação grau 3 aumenta 2,61 vezes à cada aumento de 1 unidade da altura (cm). Estes achados permitem ao enfermeiro programar condutas mais adequadas e individualizadas para cada paciente e contribuir para a otimização do tratamento. Conclusão: Quanto maior a altura da mama, a chance da ocorrência de reação de pele grau 3 é significantemente maior. / Purpose: to evaluate and classify the skin reactions under the Radiation Therapy Oncology Group (RTOG) criteria and characterize factors that can intervene with these reactions. Methods: prospective study, with 86 women submitted to adjuvant radiotherapy to the breast with a total dose of 5040 cGy, in a 6 MV Linear Accelerator. Personal data were collected and the breast size was measured (distance between the fields separation and breast height). The skin treatment area was carried out weekly. Results: breast height and treatment technique were significant factors in the univarieted analysis, for the incidence of skin reaction grade 3. However, only the breast height was a significant factor in the multivarieted analysis for the severity of the skin reaction. The possibility to occur reaction degree 3 increases 2.61 times to each increase of 1 unit of height in cm. These findings allow the nurse program specific approaches concerning to the skin care to each patient and contribute for the treatment otimization. Conclusion: the breast height was a significant factor for the severity of the skin reaction. / BV UNIFESP: Teses e dissertações

Page generated in 0.068 seconds