• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 50
  • 10
  • 10
  • 10
  • 8
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 202
  • 202
  • 70
  • 64
  • 58
  • 58
  • 51
  • 42
  • 41
  • 40
  • 35
  • 32
  • 31
  • 30
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

High-efficiency Transformerless PV Inverter Circuits

Chen, Baifeng 01 October 2015 (has links)
With worldwide growing demand for electric energy, there has been a great interest in exploring photovoltaic (PV) sources. For the PV generation system, the power converter is the most essential part for the efficiency and function performance. In recent years, there have been quite a few new transformerless PV inverters topologies, which eliminate the traditional line frequency transformers to achieve lower cost and higher efficiency, and maintain lower leakage current as well. With an overview of the state-of-the-art transformerless PV inverters, a new inverter technology is summarized in the Chapter 2, which is named V-NPC inverter technology. Based this V-NPC technology, a family of high efficiency transformerless inverters are proposed and detailly analyzed. The experimental results demonstrate the validity of V-NPC technology and high performance of the transformerless inverters. For the lower power level transformerless inverters, most of the innovative topologies try to use super junction metal oxide semiconductor field effect transistor(MOSFET) to boost efficiency, but these MOSFET based inverter topologies suffer from one or more of these drawbacks: MOSFET failure risk from body diode reverse recovery, increased conduction losses due to more devices, or low magnetics utilization. By splitting the conventional MOSFET based phase leg with an optimized inductor, Chapter 3 proposes a novel MOSFET based phase leg configuration to minimize these drawbacks. Based on the proposed phase leg configuration, a high efficiency single-phase MOSFET transformerless inverter is presented for the PV micro-inverter applications. The PWM modulation and circuit operation principle are then described. The common mode and differential mode voltage model is then presented and analyzed for circuit design. Experimental results of a 250 W hardware prototype are shown to demonstrate the merits of the proposed MOSFET based phase-le and the proposed transformerless inverter. New codes require PV inverters to provide system regulation and service to improve the distribution system stabilization. One obvious impact on PV inverters is that they now need to have reactive power generation capability. The Chapter 4 improves the MOFET based transformerless inverter in the Chapter 3 and proposed a novel pulse width modulation (PWM) method for reactive power generation. The ground loop voltage of this inverter under the proposed PWM method is also derived with common mode and differential mode circuit analyses, which indicate that high-frequency voltage component can be minimized with symmetrical design of inductors. A 250-W inverter hardware prototype has been designed and fabricated. Steady state and transient operating conditions are tested to demonstrate the validity of improved inverter and proposed PWM method for reactive power generation, high efficiency of the inverter circuit, and the high-frequency-free ground loop voltage. Besides the high efficiency inverter circuit, the grid connection function is also the essential part of the PV system. The Chapter 5 present the overall function blocks for a grid-connected PV inverter system. The current control and voltage control loop is then analyzed, modeled, and designed. The dynamic reactive power generation is also realized in the control system. The new PLL method for the grid frequency/voltage disturbance is also realized and demonstrate the validity of the detection and protection capability for the voltage/frequency disturbance. At last, a brief conclusion is given in the Chapter 6 about each work. After that, future works on device packaging, system integration, innovation on inverter circuit, and standard compliance are discussed. / Ph. D.
112

Power quality improvements in 25kV 50 Hz railway substation based on chopper controlled impedances / Amélioration de la qualité de l'energie electrique dans les sous stations ferroviaires 25kV 50Hz en utilisant des Impedances Controlees par Gradateur MLI

Raimondo, Giuliano 02 February 2012 (has links)
Ce travail est le résultat d'une collaboration entre le laboratoire LAPLACE, la "Seconda Università degli Studi di Napoli" (SUN) et la Société National des Chemins de fer Français SNCF. Le sujet de recherche concerne l'utilisation de dispositifs électroniques de puissance dans les sous stations ferroviaires 25kV/50Hz afin d’améliorer la qualité de l'énergie électrique. Dans le transport ferroviaire, le système d'électrification monophasé 25kV/50Hz est largement diffusé en particulier pour les lignes ferroviaires à grande vitesse. Bien qu'aujourd'hui les systèmes d’alimentation en courant continu soient encore largement utilisés, l'adoption du courant alternatif monophasé offre des avantages économiques pour les infrastructures d'environ 30% en termes d'investissement, d'exploitation et d'entretien. Initialement, compte tenu de la simplicité du circuit, il n'y avait aucune nécessité d'intégrer de l'électronique de puissance dans les sous stations. Toutefois, au cours de la décennie passée, l'intérêt pour ces équipements est apparu car ils peuvent apporter une solution d'optimisation du réseau lorsque le trafic augmente ou lorsqu’une nouvelle sous station est envisagée. Deux principaux types de dispositifs sont installés aujourd'hui sur le réseau ferré français : les compensateurs de puissance réactive et les compensateurs de déséquilibre de tension. Cette thèse présente de nouvelles topologies de compensateurs basées sur le concept d’impédances contrôlées par gradateur MLI. Comparées aux solutions existantes, ces topologies ont des caractéristiques particulièrement intéressantes en termes de pertes dans les semi-conducteurs et de volume des composants réactifs. Le manuscrit contient trois parties principales: La première partie présente le principe de l’électrification en 25kV/50Hz et souligne l’intérêt d’installer des moyens de compensation statique dans les sous stations. Après une description des solutions actuellement utilisées, le concept d’impédance contrôlée par gradateur MLI (CCI : Chopper Controlled Impedance ) est ensuite présenté. La deuxième partie du travail concerne l'utilisation du concept de CCI pour la compensation de puissance réactive. La sous-station SNCF de Revest est considérée comme cas d’étude. Celle-ci est équipée d'un transformateur monophasé de 60MVA dont le primaire est connecté à une ligne de transport 225kV. Deux topologies de compensateur de puissance réactive, basées sur des montages abaisseur ou élévateur de tension sont présentées. Le dimensionnement des gradateurs est effectué sur la base d'une campagne de mesures réalisée à la sous station. Des simulations numériques utilisant des formes d’ondes réelles de courant et de tension sont présentées. Des résultats expérimentaux effectués à la plateforme de test de la SNCF sur un prototype de 1,2MVAR permettent de valider le concept de CCI. La dernière partie du travail concerne le problème du déséquilibre de tension en amont de la sous station. Un circuit de Steinmetz « actif », toujours basée sur des gradateurs MLI, est présenté et étudié. La sous station SNCF d'Evron est alors considérée comme cas étude. Celle-ci comporte un transformateur de 32MVA et est connectée à une ligne de transmission 90kV. Les mesures effectuées sur le site permettent le dimensionnement du compensateur ainsi que l’utilisation des formes d'onde réelles de courant et de tension dans les simulations numériques. Une comparaison avec des solutions classiques basées sur des onduleurs 2 niveaux et 3 niveaux souligne les avantages de la solution proposée. Ainsi, les résultats des calculs et des simulations montrent que l'énergie stockée dans les éléments réactifs est réduite d’un facteur six et que les pertes dans les semi-conducteurs sont réduites de 40%. Des résultats expérimentaux obtenus sur une maquette de 1.5 kVA permettent de valider le principe du circuit de Steinmetz actif. / This work is the result of collaboration between the LAPLACE laboratory, the “Seconda Università degli Studi di Napoli” (SUN) and the French national railways operator SNCF. The research topic treated herein concerns the use of power electronic devices in 25kV/50Hz railways substations to achieve power quality improvements. In railway transportation, single-phase 25kV-50Hz electrification system is widely diffused especially for high-speed railway applications. Although electrified DC systems are still widely applied, the adoption of AC single-phase system offers economical advantages for the infrastructures of about 30% in terms of investment, exploitation and maintenance. In early ages, due to its very simple diagram, there was no necessity to integrate power electronics in substations. However, for the last decade, the interest in power electronic equipments raised since they can provide the solution for network optimization when traffic increases or when a difficulty is foreseen for a substation implementation. Two types of devices are implemented today on the French Railway Network: Reactive Power compensators and Voltage Unbalance compensators. This thesis presents an investigation into new topologies based on the concept of “Chopper Controlled Impedances”(CCI). Compared to existing solutions, the new topologies show interesting features in terms of semi-conductor losses reduction and volume of reactive components. The manuscript is developed through three main parts: Firstly, the French railways system is introduced and the interest in installing power electronic compensators in substations is highlighted. After a brief description of currently used solutions, the CCI concept is presented: the use of Pulse Width Modulated AC Choppers allows achieving structures which behave as variable impedances. In the second part, the use of CCI structures in reactive power compensation is investigated. The SNCF substation of Revest is under study. It is equipped by a 60MVA single phase transformer with the primary side connected to a 225kV transmission line. Based on the step-down or step-up functioning mode of CCIs, two topologies of reactive power compensator are presented. The converter design is developed on the base of a measurement campaign carried out at the substation. Numerical simulations using real current and voltage waveforms are presented. Finally, experimental results carried out at the SNCF test platform on a 1.2MVAR prototype are shown. In the last part, the problem of voltage unbalance is treated. Using the concept of CCI, the feasibility of an active Steinmetz circuit based on AC choppers is explored. As a case study, the substation of Evron is considered. It is a 32MVA substation connected to a 90kV transmission line. Measurements carried out on the substation site allow the compensator design and the possibility to consider real waveforms for current and voltage in numerical simulations. A comparison with classical solution based on two levels VSI and three levels NPC-VSI highlights the advantages of the proposed solution. Calculation and simulation results show that the stored energy in reactive elements is reduced by a factor six whereas the semiconductor losses are 40% lower. Experimental results obtained on a scaled demonstrator (1.5 kVA) validate the principle of the active Steinmetz circuit.
113

Meta-heurísticas aplicadas ao modelo AC no planejamento da expansão de sistemas de transmissão /

Melchor Gutiérrez, José Nicolás January 2019 (has links)
Orientador: Rubén Augusto Romero Lázaro / Resumo: Os sistemas elétricos do futuro próximo terão um comportamento dinâmico porque grandes fontes renováveis de geração, principalmente geração eólica e solar, serão construídas nos sistemas de potência de vários países do mundo incluindo o Brasil. A incerteza introduzida pelas fontes renováveis de energia é um problema que deve ser solucionado. Para resolver o problema da incerteza é necessário criar uma rede mais flexível. A alocação de armazenadores de energia no sistema de potência será necessária para lidar com as novas incertezas e para manter o funcionamento adequado do sistema. Adicionalmente, o sistema de transmissão deve-se tornar muito mais ativo através do uso de novas tecnologias flexíveis que permitirão ter um controle ótimo do sistema. As novas tecnologias incluem Sistemas Flexíveis de Transmissão em Corrente Alternada (FACTS), sistemas de transmissão de corrente continua (HVDC) e outras tecnologias que permitirão controlar as direções dos fluxos de potência sem alterar a geração ou demanda do sistema. Portanto, nesta tese são estudadas diferentes representações matemáticas para os problemas de fluxo de potência ótimo (FPO), planejamento da transmissão de longo prazo (PERT) e alocação de fontes de reativos (AFR) usando as equações de fluxo de potência de corrente alternada (CA). Adicionalmente, são propostas novas formulações para representar os problemas de fluxo de potência ótimo multiperíodo para sistemas de transmissão ativos que incluem FACTS, sistemas HVDC e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The future power systems will have a dynamic behaviour due to a significant amount of renewable generation, especially wind and solar generation, will be installed in the power systems of many countries in the world including Brazil.The uncertainty introduced by the renewable energy resources is a problem that has to be solved. The development of a flexible network is necessary to solve the aforementioned problem. The installation of energy storage in the power system will be necessary to manage the new uncertainties and to maintain the adequate system’s operation. Additionally, the transmission system will become more active though new flexible technologies, which allows having an optimal control of the power system. The new technologies include Flexible AC Transmission System (FACTS), High Voltage Direct current (HVDC) transmission systems and other technologies, which allow controlling the power flow direction without changing the power injections of generation or demand. Therefore, in this thesis are studied different mathematical formulations using the AC power flow equations for the optimal power flow (OPF) problem, the transmission expansion planning (TEP) problem and the reactive power planning (RPP) problem. Furthermore, two additional contributions have been made. The first contribution is the development of new mathematical formulations for the multiperiod optimal power flow for active transmission systems that includes FACTS, HVDC and batteries. The second contrib... (Complete abstract click electronic access below) / Doutor
114

[en] COSTS ALLOCATION OF REACTIVE POWER DEVICES / [pt] IDENTIFICAÇÃO DOS BENEFICIÁRIOS E ALOCAÇÃO DE CUSTOS DE FONTES DE POTÊNCIA REATIVA

GISELA APARECIDA SILVA N BARROS 20 May 2003 (has links)
[pt] No atual modelo econômico do setor elétrico, é necessário identificar os agentes beneficiados pelos serviços ancilares à transmissão de potência de forma a alocar adequadamente os custos de investimento, de operação e manutenção do equipamento necessário para a prestação do serviço. Entre os serviços ancilares, destaca-se o suporte de potência reativa para a regulação de tensão. Este trabalho apresenta um método baseado nos multiplicadores de Lagrange de um problema de otimização associado ao cálculo das medidas corretivas necessárias para lidar com níveis de tensão inadequados. Dois critérios de otimização são definidos: mínimo corte de carga e mínima alocação de potência reativa. Os multiplicadores de Lagrange definem a responsabilidade de cada barra quando ocorrem violações de tensão no sistema. O método permite não só identificar as barras beneficiadas pelo equipamento de compensação de potência reativa como também alocar os custos entre elas. É priorizada a confiabilidade do sistema, analisando as contingências possíveis e considerando suas respectivas probabilidades de ocorrência. O programa computacional NH2, desenvolvido pelo CEPEL, é a ferramenta básica para o desenvolvimento deste trabalho. O método é aplicado, a título de ilustração, ao sistema IEEE - RTS de 24 barras e ao sistema da Área Rio. Os resultados obtidos são comparados com um método já existente, que define fatores de alocação de custos medindo os benefícios às barras devido ao suporte de potência reativa. Esta comparação, benefício x responsabilidade, e a própria teoria dos dois métodos, mostram que o método proposto identifica mais adequadamente as barras e os respectivos fatores para a repartição dos custos. / [en] It is important to identify the agents that take advantage of the ancillary services for system operation in the nowadays electricity market. The actual economic design requires that the costs of investment, operation and maintenance of the necessary equipment should be properly allocated between these agents. Among the ancillary services, the reactive power support for voltage regulation is quite important. It is presented a method that identifies the buses that take advantage of the reactive power equipment and allocates the costs between each one of them. The power system reliability is taken into account. The analysis considers possible contingencies and their respective probability of occurrence. The computer program NH2, developed by CEPEL, is the main tool for the development of this work. The method is based on the Lagrangian multipliers of an optimal power flow problem (OPF) associated to corrective measures necessary to deal with voltage violations. Two different objective functions are used: minimum load shedding and minimum reactive power injection. The Lagrangian multipliers define the responsibility of each bus when system voltage violations occur. For the purpose of illustration, the method is applied on the 24 bus IEEE Reliability Test System and on Área Rio system. Results are compared with those produced by other existing method that defines cost allocation factors measuring the benefit due the reactive support. This comparison, benefit x responsibility, and the theory used by both methods, show that the proposed method identifies more appropriately the buses and the corresponding factors to allocate the costs.
115

[en] REACTIVE POWER SUPPORT COST ALLOCATION METHOD BASED ON CIRCUIT LAWS / [pt] MÉTODO DE ALOCAÇÃO DE CUSTOS DE SUPORTE DE POTÊNCIA REATIVA BASEADO EM LEIS DE CIRCUITOS

MARCELO DE MELO ARAUJO 06 September 2007 (has links)
[pt] Com a implantação do novo modelo econômico nos sistemas de potência, a justa remuneração das empresas provedoras de serviços ancilares tem se tornado um assunto grande importância. O suporte de potência reativa, por se tratar também de um serviço ancilar, está inserido neste contexto. Desta forma, a factível identificação dos agentes beneficiários pelo suporte, bem como as proporções deste beneficiamento podem implicar em um mecanismo viável de remuneração para os custos de cada fonte provedora. Este trabalho apresenta um método de alocação de custos pelo suporte de potência reativa baseado nos princípios fundamentais da teoria de circuitos elétricos, buscando determinar a contribuição de potência reativa de cada fonte para cada barra de carga. Para isto, é sugerida uma modelagem de fontes de tensão, que permite levar em conta a natureza local da relação Q-V, proporcionando uma abordagem simples e clara do problema. Complementarmente é apresentado um método de alocação das perdas reativas em cada ramo de transmissão entre as fontes provedoras de potência reativa. Para validar o método proposto, são realizados testes em sistemas de potência de pequeno e médio porte, apresentado as parcelas de contribuição de cada fonte de potência reativa para cada carga, e adicionalmente para as perdas reativas em cada ramo de transmissão. Comparações são estabelecidas com um método existente, onde é constatado que o método proposto apresenta maior coerência com as propriedades elétricas dos sistemas de potência, destacando-se a verificação clara da natureza local do consumo de potência reativa. Em relação aos resultados da alocação de perdas reativas, verifica-se que o método serve como indicativo sobre o uso da rede de transmissão por parte de cada fonte de potência reativa. / [en] After implantation of power systems` new economic model, a fair remuneration strategy of ancillary services suppliers had became an important issue. Reactive power support is also an ancillary service, thus, it belongs to this context. Then, identification of service beneficiaries as well as the benefit proportions may take a feasible remuneration mechanism for each source. This work presents a reactive power support cost allocation method based on fundamental principles of circuit theory, where reactive power contribution from each source to each load is calculated. This method suggests a modeling of voltage sources, which takes into account the Q-V relationship, providing a simple and clear treatment of the problem. Additionally, a reactive loss allocation method to each branch is presented. To validate the proposed method, tests with small and medium size systems are realized. So, there are presented results of reactive power demand and transmission losses allocation into systems` sources. Comparisons with an existent method are established, when we can verify that the proposed method brings more coherence with the electrical properties of power systems and the local nature of reactive power consumption. In the other hand, results of reactive losses allocation can indicate the transmission network usage by each reactive power source.
116

Proposta de uma estrutura híbrida de controle para sistemas de excitação de geradores síncronos distribuídos / Proposal of a hybrid control scheme for excitation systems of distributed synchronous generators

Piardi, Artur Bohnen 21 November 2017 (has links)
Com o advento da geração distribuída foi permitido aos sistemas de distribuição a possibilidade de operação de forma ilhada dos sistemas interligados de grande porte. Apesar de suas vantagens, do ponto de vista técnico, ainda existe uma série de desafios que necessitam ser superados para a plena aplicação desse conceito. Um desses desafios é definido pela transição dos modos operativos dos geradores distribuídos durante o processo de ilhamento. Da forma em que é reportada na literatura, infere-se que tal transição é realizada de um modo inadequado, amplificando os transitórios observados nas grandezas do gerador distribuído - e por consequência, da rede em que o mesmo se conecta - durante o processo de ilhamento, o que não é desejável. No contexto apresentado, a principal contribuição desta pesquisa está em propor uma estrutura híbrida de controle a ser aplicada aos sistemas de excitação de geradores síncronos que operam em sistemas de distribuição que permitem a operação ilhada de determinadas porções de suas redes. A principal característica da estrutura proposta está em atenuar os transitórios das variáveis do gerador controlado durante o processo de ilhamento. Além disso, o arranjo da estrutura proposta estabelece um compromisso entre a potência reativa e a tensão terminal do gerador controlado, quando o mesmo opera em paralelo com os sistemas interligados de grande porte. Nessa condição, o sistema de controle mantém a potência reativa próxima da referência ajustada atendendo a uma faixa adequada de valores de tensão terminal. / With the advent of distributed generation, the possibility of autonomous operation regarding the bulk power systems was allowed to the distribution systems. Despite its advantages, from the technical point of view, there are lots of challenges that need to be overcome for the full application of this concept. One of these challenges is the transition of distributed generators operating modes during the islanding process. Based in the literature survey, it is inferred that transition is performed in a wrong way, which amplifies the transients in controlled generator quantities and consequently, of the network connected to it during the islanding process, which is undesirable. In this context, the main contribution of this research is the proposal of a hybrid control structure to be applied to the excitation systems of synchronous generators that operate in distribution systems whose islanded operation of determined portions of its grids is permitted. The main characteristic of the proposed structure is the attenuation of transients of the controlled generator quantities during the islanding process. Furthermore, the design of this structure provides a compromise between the generator reactive power and terminal voltage when it operates in parallel with the bulk power systems. That way, the control system maintains the reactive power close to the adjusted reference attending an appropriate range of terminal voltage values.
117

Proposta de uma estrutura híbrida de controle para sistemas de excitação de geradores síncronos distribuídos / Proposal of a hybrid control scheme for excitation systems of distributed synchronous generators

Artur Bohnen Piardi 21 November 2017 (has links)
Com o advento da geração distribuída foi permitido aos sistemas de distribuição a possibilidade de operação de forma ilhada dos sistemas interligados de grande porte. Apesar de suas vantagens, do ponto de vista técnico, ainda existe uma série de desafios que necessitam ser superados para a plena aplicação desse conceito. Um desses desafios é definido pela transição dos modos operativos dos geradores distribuídos durante o processo de ilhamento. Da forma em que é reportada na literatura, infere-se que tal transição é realizada de um modo inadequado, amplificando os transitórios observados nas grandezas do gerador distribuído - e por consequência, da rede em que o mesmo se conecta - durante o processo de ilhamento, o que não é desejável. No contexto apresentado, a principal contribuição desta pesquisa está em propor uma estrutura híbrida de controle a ser aplicada aos sistemas de excitação de geradores síncronos que operam em sistemas de distribuição que permitem a operação ilhada de determinadas porções de suas redes. A principal característica da estrutura proposta está em atenuar os transitórios das variáveis do gerador controlado durante o processo de ilhamento. Além disso, o arranjo da estrutura proposta estabelece um compromisso entre a potência reativa e a tensão terminal do gerador controlado, quando o mesmo opera em paralelo com os sistemas interligados de grande porte. Nessa condição, o sistema de controle mantém a potência reativa próxima da referência ajustada atendendo a uma faixa adequada de valores de tensão terminal. / With the advent of distributed generation, the possibility of autonomous operation regarding the bulk power systems was allowed to the distribution systems. Despite its advantages, from the technical point of view, there are lots of challenges that need to be overcome for the full application of this concept. One of these challenges is the transition of distributed generators operating modes during the islanding process. Based in the literature survey, it is inferred that transition is performed in a wrong way, which amplifies the transients in controlled generator quantities and consequently, of the network connected to it during the islanding process, which is undesirable. In this context, the main contribution of this research is the proposal of a hybrid control structure to be applied to the excitation systems of synchronous generators that operate in distribution systems whose islanded operation of determined portions of its grids is permitted. The main characteristic of the proposed structure is the attenuation of transients of the controlled generator quantities during the islanding process. Furthermore, the design of this structure provides a compromise between the generator reactive power and terminal voltage when it operates in parallel with the bulk power systems. That way, the control system maintains the reactive power close to the adjusted reference attending an appropriate range of terminal voltage values.
118

Modelling of utility-scale PV systems and effects of solar irradiance variations on voltage levels. / Modelagem de sistemas fotovoltaicos de grande escala e efeitos das variações na radiação nos níveis de tensão.

Cristian Fernando Torres Montenegro 13 May 2016 (has links)
This work presents a dynamic model for utility-scale PV systems. The model is based on a centralized converter topology, which uses a voltage-sourced converter (VSC) to facilitate the exchange of energy between PV generators and the utility grid. The related control system regulates active and reactive power injected by the PV system, based on a current control strategy. Moreover, the model includes a Maximum Power Point Tracking (MPPT) scheme, implemented with the incremental conductance method. Dimensioning of the model is presented as well as simulation cases to validate its performance. Subsequently, the model was used to analyze the effect of variations in solar radiation on a test network with high penetration of photovoltaic generation. Results showed that without proper compensation of reactive power, variations in solar radiation can cause voltage fluctuations outside allowable limits. Thus, in order to mitigate these fluctuations, local control strategies were implemented to allow the exchange of reactive power between the solar farm and the utility grid. Simulations showed that the proposed strategies can mitigate voltage fluctuations at the point of common coupling, improving voltage regulation in the network. / Este trabalho apresenta um modelo dinâmico de sistemas fotovoltaicos de grande escala. O modelo é baseado em uma topologia de conversor centralizado, que usa um conversor de fonte de tensão (VSC) para facilitar a troca de energia entre os geradores fotovoltaicos e a rede elétrica. O sistema de controle relacionado regula a energia ativa e reativa injetada pelo sistema fotovoltaico, com base em uma estratégia de controle de corrente. Além disso, o modelo inclui um sistema de rastreamento de ponto de potência máxima (MPPT), implementado com o método da condutância incremental. O dimensionamento do modelo é apresentado, bem como vários casos de simulação para validar o seu desempenho. Posteriormente, o modelo foi utilizado para analisar o efeito das variações na radiação solar sobre uma rede de teste com uma elevada penetração de geração fotovoltaica. Os resultados mostraram que sem uma adequada compensação de energia reativa, as variações na radiação solar podem causar flutuações de tensão fora dos limites permitidos. Assim, a fim de mitigar estas flutuações, estratégias de controle local foram implementadas para permitir a troca de potência reativa entre os sistemas fotovoltaicos e a rede. As simulações mostraram que as estratégias propostas podem mitigar as flutuações de tensão no ponto de acoplamento comum, melhorando a regulação de tensão na rede.
119

Modelling of utility-scale PV systems and effects of solar irradiance variations on voltage levels. / Modelagem de sistemas fotovoltaicos de grande escala e efeitos das variações na radiação nos níveis de tensão.

Montenegro, Cristian Fernando Torres 13 May 2016 (has links)
This work presents a dynamic model for utility-scale PV systems. The model is based on a centralized converter topology, which uses a voltage-sourced converter (VSC) to facilitate the exchange of energy between PV generators and the utility grid. The related control system regulates active and reactive power injected by the PV system, based on a current control strategy. Moreover, the model includes a Maximum Power Point Tracking (MPPT) scheme, implemented with the incremental conductance method. Dimensioning of the model is presented as well as simulation cases to validate its performance. Subsequently, the model was used to analyze the effect of variations in solar radiation on a test network with high penetration of photovoltaic generation. Results showed that without proper compensation of reactive power, variations in solar radiation can cause voltage fluctuations outside allowable limits. Thus, in order to mitigate these fluctuations, local control strategies were implemented to allow the exchange of reactive power between the solar farm and the utility grid. Simulations showed that the proposed strategies can mitigate voltage fluctuations at the point of common coupling, improving voltage regulation in the network. / Este trabalho apresenta um modelo dinâmico de sistemas fotovoltaicos de grande escala. O modelo é baseado em uma topologia de conversor centralizado, que usa um conversor de fonte de tensão (VSC) para facilitar a troca de energia entre os geradores fotovoltaicos e a rede elétrica. O sistema de controle relacionado regula a energia ativa e reativa injetada pelo sistema fotovoltaico, com base em uma estratégia de controle de corrente. Além disso, o modelo inclui um sistema de rastreamento de ponto de potência máxima (MPPT), implementado com o método da condutância incremental. O dimensionamento do modelo é apresentado, bem como vários casos de simulação para validar o seu desempenho. Posteriormente, o modelo foi utilizado para analisar o efeito das variações na radiação solar sobre uma rede de teste com uma elevada penetração de geração fotovoltaica. Os resultados mostraram que sem uma adequada compensação de energia reativa, as variações na radiação solar podem causar flutuações de tensão fora dos limites permitidos. Assim, a fim de mitigar estas flutuações, estratégias de controle local foram implementadas para permitir a troca de potência reativa entre os sistemas fotovoltaicos e a rede. As simulações mostraram que as estratégias propostas podem mitigar as flutuações de tensão no ponto de acoplamento comum, melhorando a regulação de tensão na rede.
120

A new method for calculating the economic benefits of varying degrees of power factor correction for industrial plant loads

Ishaque, Mohammed 01 January 1992 (has links)
A comparative study of the economic benefits that can be obtained from different degrees of power factor correction for medium and small scale industrial installations is shown. A new approach for precise calculation of kws and kvars required at different power factors is presented. These calculated values are used to find the return on investments for the capacitors needed for power factor correction. The developed method is easy to use, cost effective, accurate and will help electrical engineers with minimum knowledge of power systems to precisely determine the savings available by improving the power factor of an industrial load.

Page generated in 0.0451 seconds