Spelling suggestions: "subject:"removable"" "subject:"removeable""
71 |
Ruídos articulares em pacientes parcialmente desdentados (classe I ou II de Kennedy), antes e após a reposição dental com prótese parcial removível: avaliação através da eletrovibratografiaBaleeiro, Renata Porfíria [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T18:35:12Z : No. of bitstreams: 1
baleeiro_rp_me_araca.pdf: 915852 bytes, checksum: eda0ee966910bd8f3eec26386a5fc0fa (MD5) / Universidade Estadual Paulista (UNESP) / As alterações no aparelho estomatognático parecem se originar do desequilíbrio ortopédico da mandíbula. Uma das causas desse desequilibro é a ausência do suporte oclusal que poderia conduzir a uma posição côndilo-disco inadequada na fossa mandibular, diminuição da força dos músculos elevadores da mandíbula, lubrificação deficiente. Essas mudanças podem levar ao desalojamento do disco articular e, conseqüentemente, ao aparecimento de vibrações articulares. Dessa forma, este estudo busca identificar e quantificar a presença de vibrações por meio da eletrovibratografia em articulações temporomandibulares de pacientes Classe I e/ou II de Kennedy, no momento da consulta, um ano e dois anos após o tratamento oclusal. Os resultados indicaram que as vibrações articulares foram mais freqüentes no final da abertura e do fechamento bucal. Entretanto, as vibrações diminuíram no primeiro e no segundo ano, sendo que somente após dois anos a redução foi estatisticamente significante. A redução da vibração articular verificada é sugestiva de que o suporte molar evita o desalojamento do disco e permite um fortalecimento muscular. / The alterations in stomatognathic apparatus can be originate by orthopedical disbalance of the jaw. One of the causes of orthopedical disbalance is the absence of the occlusal support that could lead to a inadequate condyle-disk position related to mandibular fossa, weakness of mandibular elevators muscles, and joints temporomandibulars deficient lubrication. These alterations can contribute to displacement of the articular disk and consequently the forthcoming of articular vibrations. This aim of this study is to identify and quantify the presence of vibrations through the electrovibratography in temporomandibular joint of Kennedy class I and/or II patient, at the initial appointment, one year and two years after the occlusal treatment. The results indicated that the articular vibrations were more frequent at the end of the opening and buccal closing. However, the vibrations decreased in the first and second year. After second years the differences were statistically significant. The reduction of the articular vibration verified is suggestive that the support molar avoids the displacement of the disk and it allows a muscular invigoration.
|
72 |
Perfil das condições sistêmicas e bucais de usuários de próteses removíveis atendidos em um Serviço de Medicina Bucal /Sposto, Maria Regina. January 1996 (has links)
Resumo: A presença de doenças sistêmicas, uso de medicamentos, e uso de próteses removíveis, entre outros fatores, podem alterar o equilíbrio fisiológico da cavidade bucal favorecendo o estabelecimento de diversas alterações e/ou patologias bucais. Assim, o estudo das prevalências destes fatores, nos pacientes odontológicos, tornam-se importantes pois devem ser considerados para elaborar o diagnóstico e definir a conduta terapêutica. Com o objetivo de delinear um perfil, avaliamos os prontuários de 500 usuários de próteses removíveis atendidos no Serviço de Medicina Bucal da Faculdade de Odontologia de Araraquara - UNESP. Analisamos os dados referentes a: características da população e das próteses removíveis, prevalência das doenças sistêmicas, uso de medicamentos e diagnóstico final das patologias ou alterações bucais. Os resultados obtidos nos permitem concluir que a maioria (74%) dos usuários de próteses removíveis eram mulheres brancas; metade da população pertencia a faixa etária de 41 a 60 anos e, quase a metade (49,2%) usava a combinação de prótese total superior e inferior. As doenças sistêmicas foram relatadas por 57,2% da amostra e a prevalência maior foi de doenças do sistema cardiovascular (25,4%). A maioria (60,4%) da população relatou uso de medicamentos e, dentre os mais freqüentes, a prevalência maior foram dos cardiovasculares (26,4%). A prevalência de patologias ou alterações bucais foi de 99,6%, sendo as relacionadas ao uso de próteses removíveis as mais freqüentes. Dentre estas, a candidose crônica atrófica ocorreu em 81,8% da população estudada e a hiperplasia fibrosa em 29,2%. / Abstract: Systemic diseases, the use of drugs and removable prosthetic appliance wearing, among others conditions, can influence the oral health, promoting the development of various oral mucosal disorders. Thus, the study of those informations on the dental patients becomes important and must be considered to estabilish the diagnosis and therapeutic management. The aim of this study was to provide descriptive epidemiologic information. For that task we have collected and analysed data from 500 files of patients, which are wearers of removable prosthetic appliances who attended at the Oral Medicine Service of Araraquara Dental School - UNESP. The results provide information about characteristics of the population and their removable appliances, prevalences of systemic diseases, use of drugs and diagnosis of oral diseases. The results allowed us to draw a profile of the population, concluding that the majority (74%) of the removable appliances wearers were white women, half of the sample with age between 41 to 60 years and almost half using an association of complete maxillary denture and complete mandibular denture. The health questionnaire indicated 57.2% of the population with systemic diseases, and the highest prevalence was of cardiovascular diseases (25.4%).The majority of the sample (60.4%) reported the use of drugs and the cardiovascular drugs were the more frequent (26.4%). The prevalence of oral diseases was 99.6%, the ones which were related with removable prosthetic were the most frequent. Among these, chronic atrophic candidosis was diagnosed in 81.8% of the sample and fibrous hyperplasia in 29.2%.
|
73 |
Avaliação clinica e radiografica de dentes retentores de protese parcial removivel em pacientes desdentados parciais Classe I de Kennedy / Clinical and radiographic evaluation of abutment tooth periodontal conditions in distal extension removable partial denture wearersMengatto, Cristiane Machado 09 February 2005 (has links)
Orientador: Celia Marisa Rizzati-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T08:23:17Z (GMT). No. of bitstreams: 1
Mengatto_CristianeMachado_M.pdf: 911060 bytes, checksum: 2e1e0d90cd78db26bbc3b3ab221b99f9 (MD5)
Previous issue date: 2005 / Resumo: A maioria dos estudos anteriores a respeito dos efeitos do uso de próteses parciais removíveis (PPRs) sobre as condições periodontais dos dentes retentores demonstraram resultados contraditórios, e variabilidade nos métodos de padronização e avaliação. O objetivo desse estudo foi avaliar clinica e radiograficamente as condições periodontais dos dentes retentores diretos de prótese parcial removível (PPR) em pacientes edêntulas na arcada superior, e parcialmente dentadas (Classe I de Kennedy) na arcada inferior. Foram investigados: Índice Dicotômico de Placa (IPL), Índice de Sangramento à Sondagem (ISS), Mobilidade Dental (MD), Nível Clínico de Inserção Relativo (NCIR), Profundidade de Sondagem (PS), Nível da Margem Gengival (NMG), e Altura da Crista Óssea Percentual (ACOP). As avaliações foram feitas antes (t0) e após seis meses (t1) da instalação das próteses, com auxílio de sonda periodontal eletrônica de pressão controlada, guias para sondagem, registro oclusal em silicone para padronização das radiografias, e de um software (Image Tool®) para mensuração das radiografias periapicais. Para comparações que atenderam as pressuposições das análises paramétricas, utilizou-se o teste-t para amostras pareadas, para as que não atenderam, utilizou-se o teste de Wilcoxon para amostras pareadas, a 5% de significância. Entre t0 e t1, houve aumento estatisticamente significativo do IPL, ISS e MD (p<0,05); diminuição da ACOP distal (p<0,05); perda do NCIR e aumento da PS para as faces mesial, distal e lingual (p<0,05); perda do NCIR e diminuição do NMG para a face vestibular (p<0,05). Não houve diferença estatística significativa entre t0 e t1 para PS na face vestibular, ACOP mesial e NMG para a face lingual, mesial e distal (p>0,05). Considerando as condições deste estudo, concluiu-se que houve piora do acúmulo de biofilme e inflamação gengival, e das condições periodontais clínicas e radiográficas dos dentes retentores diretos após seis meses de uso da PPR de extensão distal / Abstract: Most previous studies about the influence of removable partial dentures (RPD) in periodontal conditions of abutment teeth have shown contradictory results, and variability regarding the methods of standardization and evaluation. Consequently, few comparisons can be made with the literature, as there is little systematic approach about the information reported. The aim of this study was to evaluate periodontal conditions of abutment teeth of 19 female patients (45 to 79 years old) rehabilitated with distal extension mandibular RPD and maxillary complete denture. Initially all were given oral hygiene instructions and motivation. Plaque index (PI), bleeding on probing (BOP), tooth mobility (TM), relative attachment level (RAL), probing depth (PD), gingival margin level (GML), and radiographic height of alveolar bone crest (HAC) were assessed immediately prior to (t0) and six months after (t1) prosthesis setting. Evaluations were carried with electronic periodontal probe, acrylic probing stents, and customized silicone occlusal stents to facilitate standardized periapical radiographs of abutment teeth. Radiographic measurements were taken by special software (Image Tool). Data were submitted either to paired Wilcoxon test or paired t-test, at 5% significance. There were increase in PI, BOP and TM; reduction of HAC for distal surface; attachment loss and increase in PD for mesial, distal and lingual surfaces; attachment loss and reduction in GML for buccal surface (p<0.05). There was no significant statistical difference between t0 and t1 in PD for buccal surface, HAC for mesial surface, and GML for lingual, mesial and distal surfaces (p>0.05). Within the limitations of the present study, it was concluded that biofilm accumulation, gingival inflammation, and periodontal and radiographic conditions of abutment teeth deteriorated six months after prosthesis setting / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
74 |
Efeito da reabilitação protetica removivel bucal na espessura muscular e força de mordida em crianças na dentição mista / Effect of the removable prosthetic rehabilitation on muscle thickness and bite force of children in the mixed dentitionSerra-Vicentin, Marcia Diaz 22 February 2006 (has links)
Orientador: Maria Beatriz Duarte Gavião / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T02:26:00Z (GMT). No. of bitstreams: 1
Serra-Vicentin_MarciaDiaz_M.pdf: 1071000 bytes, checksum: 4ba29129af85ef19f21717f7287f9119 (MD5)
Previous issue date: 2006 / Resumo: O objetivo deste estudo foi avaliar a força de mordida e a espessura dos músculos mastigatórios em 25 crianças com perda precoce de dentes decíduos posteriores antes e após reabilitação bucal com prótese parcial removível. Para tanto, o estudo é composto de três capítulos. No capítulo 1, intitulado Maximum bite force ¿ a review of the literature, realizou-se a revisão de literatura sobre força de mordida e discorreu-se sobre as variáveis influenciadoras. A revisão mostrou que a força de mordida tem sido amplamente avaliada e associada às variáveis morfológicas e funcionais do sistema mastigatório. No capítulo 2 intitulado A six-month evaluation of maximum bite force in wearing a removable dental prosthesis avaliou-se a força de mordida das crianças, e no capítulo 3, intitulado Masseter and temporalis muscle thickness of children wearing removable dental prosthesis ¿ a six-month evaluation avaliou-se a espessura dos músculos masseter e porção anterior temporal através da ultra-sonografia. Avaliou-se também as variáveis corporais, representadas por proporções faciais, peso e altura nos capítulos 2 e 3. A força de mordida foi obtida utilizando-se um transmissor constituído de um tubo de fibra reforçada, pressurizado, conectado ao sensor de pressão (MPX 5700 Motorola). A espessura dos músculos foi avaliada nas posições mandibulares de máxima contração e repouso, com o equipamento digital Just Vision 200 (Toshiba Corporation, Japão), com transdutor linear de 56 mm, banda-larga de 10 MHz. As proporções faciais foram determinadas através de mensurações da face em fotografias padronizadas. Na análise dos dados do segundo e terceiro capítulo utilizou-se o teste de Shapiro-Wilk para verificação da normalidade da distribuição dos dados. Os testes t pareado e t independente, Wilcoxon, Mann-Whitney, Correlação de Pearson ou de Spearman e modelos de regressão ajustados foram aplicados quando indicados, com nível de significância de 5%. Os resultados mostraram que não houve diferenças estatísticas entre os sexos para nenhuma das variáveis (p>0,05). Houve aumento significativo de espessura muscular entre contração e repouso; entre força de mordida e espessura do masseter (relaxado e contraído) após 6 meses da instalação do aparelho protético; o músculo temporal relaxado mostrou-se maior antes da instalação do aparelho protético (p<0,05), o que não aconteceu para o temporal contraído (p>0,05). Não foram encontradas correlações entre proporções faciais e espessura muscular ou força de mordida (p>0,05). Considerando as variáveis corporais, houve correlação significativa entre espessura do masseter relaxado e altura corpórea na primeira sessão de exames, e entre espessura do masseter (contraído e relaxado) e todas as variáveis corporais na segunda sessão (p<0,05); com relação ao temporal, foi encontrada correlação significativa entre o músculo contraído e altura corpórea na primeira sessão e entre o músculo relaxado e peso corpóreo na segunda sessão de exames (p<0,05). Com relação à força de mordida foi encontrada correlação com altura corpórea somente segunda sessão de exames (p<0,05). Dentro dos limites deste estudo podemos concluir que a prótese parcial removível influenciou os aspectos morfológicos dos músculos, determinado aumento da espessura muscular, e o aspecto funcional, aumentando a força de mordida / Abstract: The aim of this study was to evaluate the maximum bite force and the thickness of the masseter and anterior portion of the temporalis muscles in twenty-five children with early loss of primary teeth, before and six months after oral rehabilitation with removable dental prosthesis. Three chapters compose the study. In chapter 1, entitled Maximum bite force ¿ a review of the literature, a review of the pertinent literature about maximum bite force was done, and the influencing variables were discussed. The review showed that bite force has been widely evaluated and associated to the morphological and functional variables of the masticatory system. The second chapter, entitled A six-month evaluation of maximum bite force in wearing a removable dental prosthesis it was evaluated the bite force of the children; and in chapter 3, entitled Masseter and temporalis muscle thickness of children wearing removable dental prosthesis ¿ a six-month evaluation evaluated the thickness of the masseter and anterior portion of the temporalis muscles by means of ultrasonography. Also, it was evaluated the body variables, represented by facial proportions, weight and height in chapters 2 and 3. Bite force was determined with a pressurized transducer, which consisted of a pressurized rubber tube connected to a sensor element (MPX 5700, Motorola SPS, Austin, TX, USA). Muscle thickness was measured during relaxation and maximum clenching, using the Just-vision 200 digital ultrasonography system (Toshiba Corporation, Japan) with a high-resolution real-time 56 mm/10-MHz linear-array transducer. Facial proportions were determined through measurements of the face in standard photographs. For data analysis in the second and third chapters, the normality of the distributions was assessed by the Shapiro-Wilks W-test. The t paired or unpaired tests, Wilcoxon, Mann-Whitney, Pearson¿s or Spearman¿s Correlations and linear regression were applied as indicated, with significance level of 5%. The results showed no statistical differences between genders for any of the variables (p>0.05). There was statistical significant increase in muscle thickness from relaxation to clenching; between bite force and masseter muscle thickness both during clenching and relaxation from the first to the second evaluation; the temporalis muscle was thicker in before the placement of the prosthetic device (p<0.05), which did not happen for the contracted temporalis. There were not correlations between facial proportions and muscle thickness or bite force (p>0.05). Considering the body variables, there was a significant correlation between masseter muscle thickness during relaxation and body height in the first evaluation, and between masseter muscle thickness (both contracted and relaxed) and all the body variables in the second evaluation (p<0.05). In relation to the temporalis muscle, it was found a significant correlation between the contracted muscle and height in the first evaluation, and between the relaxed muscle and weight in the second evaluation (p<0.05). In relation to the bite force, there was only a correlation with body height in the second evaluation (p<0.05). Within the limitations of this study, it can be concluded that the removable dental prosthesis influenced the morphology of the muscles, determining an increase in muscle thickness, and the function, increasing the bite force / Mestrado / Odontopediatria / Mestre em Odontologia
|
75 |
Função mastigatoria em crianças apos a reabilitação protetica removivel bucal / Masticatory function in children after oral rehabilitationGambareli, Flavia Riqueto 24 February 2006 (has links)
Orientador: Maria Beatriz Duarte Gavião / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T08:16:33Z (GMT). No. of bitstreams: 1
Gambareli_FlaviaRiqueto_M.pdf: 685304 bytes, checksum: 895caadd40aaa440b444f7b5a65c183a (MD5)
Previous issue date: 2006 / Resumo: O objetivo deste trabalho foi avaliar a performance mastigatória, a atividade eletromiográfica dos músculos masseter e porção anterior do temporal e a mastigação de alimentos de diferentes consistências em crianças na fase de dentição mista, com perda precoce de dentes decíduos posteriores, antes e após reabilitação protética. Para tanto, o estudo foi composto por três capítulos. No capítulo 1, intitulado Influence of measurement technique, test food, teeth and muscle force interactions in masticatory performance evaluation, realizou-se a revisão de literatura sobre performance mastigatória e discorreu-se sobre as variáveis influenciadoras. A revisão mostrou que a performance mastigatória tem sido amplamente avaliada e associada às variáveis morfológicas e funcionais do sistema mastigatório. No capítulo 2, intitulado Masticatory performance before and after oral rehabilitation in children, avaliou-se a performance mastigatória com alimento teste artificial. No capítulo 3, intitulado The influence of oral rehabilitation on muscle activity and chewing behavior in partially edentulous children, avaliou-se a atividade eletromiográfica dos músculos masseter e porção anterior do temporal e o comportamento mastigatório com alimentos de diferentes consistências. Avaliou-se também as variáveis corporais, peso e altura em ambos os capítulos. A performance mastigatória foi avaliada através da mastigação de um material à base de silicona, utilizando o sistema de peneiragem fragmentada para determinar o tamanho das partículas após mastigação. Para o registro eletromiográfico, foram utilizados o sistema de aquisição de sinais (EMG System do Brasil Ltda.) e o software Aqdados ¿ versão 5.0 da Lynx Eletrônica Ltda. O sinal eletromiográfico foi captado em contração voluntária máxima bilateral tendo o material Parafilm entre os molares e em mastigação habitual com alimento teste artificial. Os alimentos utilizados para avaliação da mastigação foram: goma de mascar (Trident tutti fruit, Adams), cenoura crua, queijo polenghi, banana nanica, torrada industrializada. Na análise dos dados do segundo e terceiro capítulos utilizou-se o teste de Shapiro-Wilk para verificação da normalidade da distribuição dos dados. Os Testes t pareado, Wilcoxon, Kruskal-Wallis e post hoc Dun, Correlação de Pearson e Spearman e regressão linear foram aplicados quando indicados, com nível de significância de 5%. Os resultados mostraram que não houve diferença estatística entre os sexos para nenhuma das variáveis (p>0.05). Houve um decréscimo significativo para o tamanho da partícula mediana antes e após 6 meses da instalação do aparelho protético (p<0,001). A atividade muscular foi significativamente maior na segunda avaliação durante a mastigação do alimento artificial (p<0,05). Considerando as variáveis corporais, houve correlação negativa significativa entre performance mastigatória, altura e peso na primeira sessão de exames (p<0,05), e não houve correspondentes correlações na segunda sessão de exames (p>0,05). Houve diferenças significativas no número de ciclos mastigatórios até a deglutição, duração da mastigação e a quantidade de alimento ingerida tanto para os alimentos duros quanto macios nas duas avaliações. A prótese parcial removível influenciou os aspectos funcionais dos músculos, determinando melhora da eficiência mastigatória e aumento da atividade muscular / Abstract: The aim of this study was to evaluate the masticatory performance, the electromyographic activity of the masseter and temporal anterior muscles and the chewing of foods of different consistency in children in the phase of mixed dentition, with early loss of posterior deciduous teeth, before and six months after oral rehabilitation with removable dental prosthesis. Three chapters compose the study. In chapter 1, entitled Influence of measurement technique, test food, teeth and muscle force interactions in masticatory performance evaluation, a review of the pertinent literature about masticatory performance was done, and the influencing variables were discussed. The review showed that masticatory performance has been widely evaluated and associated to the morphological and functional variables of the masticatory system. The second chapter entitled Masticatory performance before and after oral rehabilitation in children evaluated the masticatory efficiency with artificial test food. The third chapter entitled The influence of oral rehabilitation on muscle activity and chewing behavior in partially edentulous children evaluated the electromyographic activities of the masseter and temporal anterior muscles and the chewing of foods of different consistency. Also, it was evaluated the body variables, weight and height, in these two chapters. The masticatory performance was evaluated by the mastication of a silicone impression material, using the fragmented sieving system to determine the size of the chewed particles. For the electromyographic record, were used the system of acquisition of signs (EMG System of Brazil Ltd.) and software Aqdados-version 5.0 of Lynx Eletrônica Ltd. The electromyographic sign was captured in maximum bilateral voluntary contraction having the Parafilm material among the molars and in habitual mastication with artificial tests food. The foods for the chewing evaluation were: chewing gum raw carrot, polenghi cheese, banana and industrialized toast. For data analysis in the second and the third chapters, the normality of the distributions was assessed by the Shapiro-Wilks W-test. The t paired tests, Wilcoxon, Kruskal-Wallis and pos hoc Dun, Pearson¿s or Spearman¿s Correlations and linear regression were applied as indicated, with significance level of 5%. The results showed no statistical differences between genders for any of the variables (p>0.05). There was a significant decrease in the median particle size from first to second evaluation (p=0.000). The muscle activity was significantly greater on the second evaluation during the chewing of the artificial food (p<0.05). Considering the body variables, there was a significant negative correlation between masticatory efficiency, body height and weight in the first session of exams. After 6 months of the placement of the prosthesis no significant correlations were found for these variables (p<0.05). It was observed significant differences in number of cycles until swallowing, chewing duration and amount of food ingested for the soft and hard foods, at the two evaluations. Within the limitations of this study, it can be concluded that the removable dental prosthesis influenced the function of the muscles, determining an increase in the masticatory efficiency and an increasing in the muscle activity. It was considered that the body alterations could have been consequences of the enhancement in the masticatory function determined by the oral rehabilitation / Mestrado / Odontopediatria / Mestre em Odontologia
|
76 |
Avaliação qualitativa das proteses removiveis e sua relação com a qualidade de vida em idososOliveira, Gesiamy Francisco de 31 July 2006 (has links)
Orientador: Eduardo Hebling / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T06:12:52Z (GMT). No. of bitstreams: 1
Oliveira_GesiamyFranciscode_M.pdf: 190517 bytes, checksum: 6ad0ddc8b300886d14c0ba4ff3b17674 (MD5)
Previous issue date: 2006 / Resumo: As alterações funcionais e o estado psicológico podem influenciar a saúde bucal e o uso de próteses removíveis em pacientes idosos. A autopercepção da saúde bucal tende a influenciar a procura por atendimento e a qualidade de vida e autopercepção de saúde bucal dos idosos. O objetivo desse trabalho foi avaliar a qualidade das próteses removíveis, parciais ou totais, e sua relação com a qualidade de vida de idosos institucionalizados de Piracicaba-SP, Brasil. A amostra foi constituída de 40 pessoas, de ambos os gêneros, com média de idade de 75 anos, funcionalmente independentes ou parcialmente dependentes, sem alterações cognitivas significantes. Foi aplicado um questionário sobre as características sócio-econômicas e de saúde sistêmica da amostra. A qualidade de vida foi avaliada com uso do Geriatric Oral Health Assessment Index (GOHAI) e da Escala de Depressão Geriátrica. A qualidade das próteses removíveis foi avaliada pelo índice de Nevalainen. Os dados foram analisados por meio dos testes Qui-quadrado, Kruskal-Wallis e Mann-Whitney (a=0,05). Não houve associação estatísticamente significantes entre as variáveis sócio-econômicas, quando comparadas com a autopercepção em saúde. Quanto ao uso de próteses removíveis, 62,5% usavam em ambas arcadas; 20% somente na arcada superior e 17,5% não usavam nenhuma prótese. Do total da amostra, 62,5% apresentavam depressão. Não foram observadas diferenças estatísticas significantes entre as médias de GOHAI com relação à oclusão, articulação e dimensão vertical. Entretanto, estas médias foram influenciadas pela estabilidade e pela retenção das próteses. Pode-se concluir que as próteses removíveis podem influenciar a qualidade de vida e a autopercepção de saúde bucal em idosos / Abstract: Functional alterations and psychological status influence in the oral health and the use of removable prostheses in elderly patients. The self-perception of oral health influences in the search for oral cares and the quality of life of the aged population. The aim of this study was to assess the quality of removable prostheses, total or partial, and its relation to the quality of life in institutionalized elderly from Piracicaba-SP, Brazil. The sample was constituted for 40 subjects, both gender, mean age of 75 years old, functionally independent or partially dependent, without significant cognitive alterations. A questionnaire with questions about the sociodemographic and systemic health characteristics was applied. The quality of life was assessed using the Geriatric Oral Health Assessment Index (GOHAI) and the Geriatric Depression Scale. Removable prosthesis quality was assessed using the Nevalainen index. The data were analyzed using Chi-Square test, Mann-Whitney test and Kruskal-Wallis test (a=0.05). No significant statistics differences were found in the socioeconomic variables. In relation to the use of removable prostheses, 62.5% used prostheses in both arcades; 20% in only upper arcade, and 17.5% used no prostheses. Of total sample, 62.5% showed depression. No significant statistics differences were found between the GOHAI averages related to the occlusion, articulation, and vertical dimension of the prostheses. However, stabilization and retention of the prostheses influenced these averages. The conclusion is that the quality of life and oral health self-perception in the elderly may be influenced by the quality of removable prostheses used. / Mestrado / Mestre em Saude Coletiva
|
77 |
Protese parcial removivel de extremidade livre associada a um implante osseointegrado : estudo atraves do metodo dos elementos finitosRocha, Eduardo Passos 25 June 2001 (has links)
Orientador: Altair A. Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:43:29Z (GMT). No. of bitstreams: 1
Rocha_EduardoPassos_D.pdf: 4550295 bytes, checksum: 68320e2f849e4ffbb6731204012d540e (MD5)
Previous issue date: 2001 / Resumo: Os dados sobre a associação entre os implantes osseointegrados e a prótese parcial removível de extremidade livre (PPREL) são poucos e inconclusivos. Devido a isso, foi objetivo deste trabalho avaliar através do método dos elementos finitos bidimensional (MEF) a distribuição das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado - Sistema Branemark - de 10,0 x 3,75 mm, localizado na porção distal do rebordo alveolar, atuando como suporte para a base da PPREL. Para isto, foram criados 3 modelos, que em corte sagital representaram: Modelo A (MA) - Hemiarcada contendo os dentes naturais 33 e 34, e ausência dos dentes 35, 36 e 37; Modelo B (MB) - Semelhante ao MA, com uma PPREL convencional, substituindo os dentes ausentes; Modelo C (MC) - Semelhante ao MB, com um implante na região posterior do rebordo, servindo como suporte. Com o auxílio do programa de elementos finitos, ANSYS 5.5, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. O mapa de tensões evidenciou máxima e mínima concentração de tensões de (MPa): MA (39,668 e 0,005); MB (72,430 e 0,736) e MC (205,662 e 0,057). O deslocamento máximo foi (em mm): MA (0,064); MB (0,107) e MC (0,099). A presença da PPREL (MB) solicitou mais as estruturas de suporte em comparação ao MA; a presença do implante (MC) permitiu níveis de tensão Menores na parte posterior do rebordo alveolar e níveis semelhantes no dente 34, suporte da PPREL, quando comparados aos valores do MB; com níveis elevados de tensão no corpo do implante. Conclui-se Que a presenca da PPREL proporcionou maiores valores de tensão para as estruturas de suporte e Que a presenca do implante osseointearado proporcionou suporte para a base da PPREL. diminuindo a intrusão desta sobre a fibromucosa. promovendo menores níveis de tensão na porcão posterior do rebordo / Abstract: Little is know about the association of osseointegrated implant with a distal extension removable partial denture (DERPD). In view of that, a two-dimensional finite element analysis (FEA) was carried out to study the association of Branemark implant 10. O x 3.75 mm with DERPD, located in the dista! portion of the alveolar edge, acting as support. For this, 3 plane strain models were created, represented in sagital cut: Model A (MA) - Hemiarc containing the natural teeths 33 and 34, and absence of the teeths 35. 36 and 37; Model B (MB) - Similar to MA, with a conventional DERPD; Model C (MC) Similar to MB, with one implant in the retromolar area. The models were loaded with vertical forces of 50 N in finite element program, ANSYS 5.5. The stresses map showed for the maximum and the minimum von Mises stresses, the following values (Mpa), respectively: MA (39.668 and 0.005); MB 72.430 and 0.736) and MC (205.662 AND 0.057). The maximum displacement were (mm): MA (0.064); MB (0.107) and MC (0.099). The presence of DERPD (MB) requested more the support structures in comparison with the MA; the presence of implant (MC) allowed smaller stresses levels in the alveolar edge and similar levels in the tooth 34, support of RPD, when compared to the values of MB; and high levels of stress in the implant body. Thus. the presence of DERPD provided laraer stresses values for the support structures and that the presence of the implant provided support tor the DERPD base. reducina the intrusion on the fibromucosa. promotina smaller stresses levels in the subseauent portion of the edae / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
78 |
Avaliação de satisfação dos usuários e qualidade das Próteses Parcial Removível instaladas na clínica de graduação da FOUSP entre 2010-2014 / Satisfaction evaluation and quality of removable partial dentures in the FOUSP undergraduate clinic between 2010-2014Marcelli Soares de Souza Camargo 06 June 2016 (has links)
O objetivo deste trabalho foi avaliar a qualidade e satisfação das próteses parciais removíveis instaladas na clínica da graduação da disciplina de prótese removível no período de 2010-2014. Os pacientes que participaram da clínica nesse período foram contactados por telefone e convidados a participar da clínica de retorno da disciplina e ao mesmo tempo verificar a qualidade das próteses e a satisfação do paciente. Do total de 284 próteses instaladas nesse período, 50 foram avaliadas neste trabalho. Os pacientes que aceitaram participar da pesquisa preencheram 4 questionários: 1) TCLE, 2) Mini-mental; 3) GOHAI e 4) Anamnese da Prótese. Das próteses presentes no estudo classificaram-se em Perfeitas (sem queixa) e Problemáticas (com queixa). Após preenchido os questionários, relacionou-se a queixa principal com arco restaurado, análise da oclusão presente na prótese em função na boca, qualidade da sela, higienização da prótese e o momento em que a falha é decorrente. Como conclusão, teve-se que a queixa \"soltar sozinha\" foi a de maior destaque e está relacionada ao momento da falha pós- instalação. As próteses mal adaptadas estão relacionadas com uma qualidade de vida prejudicada e isto reforça que os retornos periódicos para controle da prótese são fundamentais para o sucesso clínico da prótese. / The objective of this study was to evaluate the quality and satisfaction of removable partial dentures installed in removable prosthesis undergraduate clinic in the 2010-2014 period. Patients attending the clinic during this period were contacted by telephone and invited to participate in the discipline of clinical and return at the same time check the quality of prosthetics and patient satisfaction. Of the total of 284 implants installed during this period, 50 were evaluated in this study. Patients who agreed to participate completed 4 questionnaires: 1) TCLE, 2) MiniMental, 3)GOHAI and 4) anamnesis of the prosthesis. Prostheses present in the study were classified in Optimal (without complaint) and Problematic (complaining). Thus, the complaint related to restored arch, occlusal analysis in the function of the prosthesis, saddle quality, denture cleaning and the time when the failure is due. In conclusion, it was that the complaint \"drop alone\" was the most prominent and is related to the time of after installation failure. Poorly adapted prostheses are associated with impaired quality of life and this reinforces that the periodic returns to the prosthesis control are fundamental for clinical success of the prosthesis.
|
79 |
\"Avaliação comparativa por meio de eletromiografia de superfície do padrão de comportamento dos músculos masseter e temporal em pacientes parcialmente edentados antes e após a reabilitação com próteses parciais removíveis\" / Comparative evaluation through surface electromyograph of the temporal and masseter muscles behaviour pattern in partially edentulous patients before and after removable partial denture rehabilitation.Jéssica Nery Navarro 15 March 2007 (has links)
Como um procedimento de avaliação, a eletromiografia clínica de superfície, envolve a detecção e o registro de potenciais elétricos de fibras musculares esqueléticas, fornecendo um instrumento útil para documentar o papel do músculo na atividade física e para avaliar a integridade do sistema neuromuscular. Tendo em vista sua utilidade, somada a relatos na literatura da existência de comprometimento muscular nos pacientes parcialmente edentados, e ainda a inexistência de relatos literários sobre a modificação do padrão de atividade muscular nos pacientes parcialmente edentados após a reabilitação; nosso objetivo nessa pesquisa foi registrar e comparar eletromiograficamente, as atividades musculares, de pacientes classe I e II de Kennedy (edentados posteriores uni ou bilaterais) em um dos arcos, antes e de 2 a 3 semanas após a instalação de próteses parciais removíveis (PPRs) e assim verificar o comportamento dos músculos masseter direito e esquerdo e temporal (feixe anterior) direito e esquerdo nessas duas situações durante a execução de abertura máxima, contração isométrica máxima voluntária (CIMV), repouso e mastigação. Após a realização desse estudo, pudemos concluir que a utilização das PPRs, restabelece os contatos oclusais posteriores perdidos e desta forma, modifica para melhor as atividades eletromiográficas da musculatura em questão (masseter e temporal). Os pacientes monitorados apresentaram um aumento extremamente significante (p < 0,0001) da eficiência da musculatura estudada durante a mastigação e ainda uma diminuição, também extremamente significante (p < 0,0001), da atividade elétrica dos masseteres e temporais durante o período de repouso e na execução da abertura máxima. / As an evaluation proceeding, the clinical surface electromyograph, envolves the detection and the registration of electric potential of muscular skinny fibers, being an useful instrument to verify the hole of the muscle in the physical activity and to evaluate the neuromuscular system condition. Keeping in mind its usefulness, added up to literature reports of the existence of muscular compromising in the partially edentulous patients, and also, the non-existence of literary articles reporting modification of muscular activity pattern in partially edentulous patients after the oral rehabilitation; our purpose in doing this research is register and compare by electromyographic study, the muscular activities, of Kennedy class I or II patients (uni or bilateral partially edentulous) in one of the arches, before and after the installation of removable partial dentures (RPDs) and also, check the behaviour of the elevator muscles: right and left masseter and right and left anterior temporal in these two situations during the execution of maximal opening, maximal isometric voluntary contraction (MIVC), rest and mastication. At the end of this study, we could conclude that the use of the RPDs, restores the oclusal contats (previously lost) and in this way, modifies the electromyographic activities of the evaluated muscles (masseter and anterior temporal). The monitored patients presented an increase extremely significant (p < 0,0001) of the musculature efficiency during the mastication and also, an extremely significant reduction (p <0,0001), of the electric activity of the four muscles during the period of rest and during the maximal opening movement.
|
80 |
Análise fotoelástica das cargas aplicadas em próteses parciais removíveis nas grandes perdas de maxila / Photoelastic analysis of the loads applied to removable partial dentures in large ressections of maxillaGiorgia Borges de Carvalho 12 December 2012 (has links)
Este trabalho teve a finalidade de avaliar pela técnica fotoelástica, o efeito que a prótese parcial removível teria, em aliviar as tensões sobre as raízes dos dentes. Para tanto preparamos um modelo com três tipos de desenhos de próteses parciais removíveis, simulando uma reabilitação nas grandes perdas de maxila. Todos os modelos de desenhos apresentaram planos guias em incisivo central e segundo molar, e se diferenciaram da seguinte forma: modelo 01, grampo circunferencial simples em canino, grampo gêmeo entre primeiro e segundo pré-molar e grampo gêmeo entre primeiro e segundo molar; modelo 02, utilizamos os mesmos grampos colocados no modelo 01 incluindo neste modelo um recobrimento palatino, modelo 03, grampo gêmeo entre canino e primeiro pré-molar, grampo gêmeo entre segundo pré-molar e primeiro molar e grampo circunferencial simples em mesial de segundo molar. Foram aplicadas cargas verticais de 10 kg, 15 kg e 20 kg em canino, segundo pré-molar e primeiro molar. Os resultados permitiram concluir que: Os planos guia comprovaram sua efetividade através do contato pleno nos dentes preparados para o seu assentamento. O recobrimento palatino não amenizou as cargas nas raízes dos dentes. Os grampos gêmeos, colocados em uma posição mais anterior, indicam uma distribuição melhor das tensões. Os grampos circunferenciais simples, colocados mais posteriormente, indicam uma melhor distribuição das tensões. Os modelos 01 e 02 apresentaram maiores tensões em incisivo central comparados com o modelo 03. O modelo 03 foi o que melhor distribuiu as cargas de forma mais equilibrada mostrando tensões de menor magnitude. Os melhores modelos de próteses parciais removíveis, pela perspectiva de transferência de tensão foram primeiramente o modelo 03, depois o modelo 01 e por fim o modelo 02. A mudança do desenho da PPR alterou a distribuição das tensões nos dentes dos modelos avaliados. / This study aimed to evaluate by the photoelastic technique, the effect that the partial denture would have to reduce tensions on the roots of teeth. For this reason, was prepared a model with three types of removable partial dentures designs, simulating rehabilitations in large ressections of maxilla. All models presents guide-planes on central incisor and second molar, and was differentiated as follows: Model 01, simple circumferential clasp in canine, twin clasps between first and second premolar and twin clasps between first and second molar; model 02, we use the same clasps as model 01 only including a palatal covering in this model, model 03, twin clasps between canine and first premolar, twin clasps between second premolar and first molar and simple circumferential clasp at mesial of second molar. Were applied vertical loads of 10 kg, 15 kg and 20 kg in canine, second premolar and first molar. The results showed that: The guide-planes proved its effectiveness through full contact in the teeth prepared for their settlement. The palatal covering failed to alleviate the stress on the roots of teeth. Twins clasps, placed in a more anterior position, indicating a better distribution of stresses. Simple circunferencial clasp, placed in a more posterior position indicating a better distribution of stresses. Models 01 and 02 had higher tensions in central incisor compared with the model 03. The Model 03 was the best considering equilibrated load distribution showing stress of lesser magnitude. The best models of removable partial dentures, from the perspective of stress transfer were first model 03, followed by the model 01 and then finally the model 02. The change os design of RPD changed the distributions os tensions in teeth of evaluated models.
|
Page generated in 0.0419 seconds