• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparación in vitro de la resistencia a la compresión de diferentes marcas de cemento ionómero de vidrio autocurable en la técnica de art

Dávila Ramírez, Carolina Melky, Barandiarán Calderón, Bruno 07 November 2018 (has links)
Objetivo: Comparar in vitro, la resistencia compresiva de cinco cementos ionómeros de vidrio: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), Maxxion R (FGM), y KetacTM Universal HM (3M ESPE); tras 24 horas, 7 y 60 días de mezclado. Materiales y métodos: Se seleccionaron tres cementos de ionómero de vidrio de alta viscosidad: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), y dos cementos de ionómero de vidrio convencionales: Maxxion R (FGM), KetacTM Universal HM (3M ESPE), indicados para el Tratamiento Restaurador Atraumático (TRA). La manipulación fue realizada en estricto cumplimiento con las indicaciones del fabricante. La unidad de análisis fue conformada por cilindros de ionómero de vidrio (2 mm de alto x 4 mm de diámetro), elaborados en una matriz metálica. Se crearon 15 especímenes por cada grupo de estudio, obteniendo un total de 225 especímenes. La prueba de resistencia a la compresión se dio mediante la máquina universal Instron® colocando los especímenes uno por uno verticalmente. La carga compresiva inicial tuvo una velocidad de 1mm/min hasta que la muestra se fracturase, y los resultados se registraron en megapascales (MPa). Resultados: El ionómero encapsulado GC EQUIATM Fil (Gc corporation) mostró mayores valores de resistencia compresiva a las 24 horas (299.80 MPa), mientras que a los 7 y 60 días fue el KetacTM Universal HM (3M ESPE), 77.04 MPa y 75.48 MPa, respectivamente. Por otro lado, existen diferencias significativas en la comparación de cada cemento de ionómero de vidrio en los tres tiempos de evaluación. Así como también, existen diferencias significativas en los tres tiempos evaluados: 24 horas: GC GC EQUIATM Fil (Gc corporation), a los 7 y 60 días KetacTM Universal HM (3M ESPE). Conclusión: El ionómero encapsulado GC EQUIATM Fil (Gc corporation) mostró mayores valores de resistencia compresiva a las 24 horas. Existen diferencias significativas en la comparación de cada cemento de ionómero de vidrio a lo largo de los tres tiempos, asimismo en cada tiempo de evaluación: 24 horas: GC EQUIATM Fil (Gc corporation), a los 7 y 60 días KetacTM Universal HM (3M ESPE). Objective: The aim of the present research was to compare in vitro the compressive strength of five glass ionomer cements: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), Maxxion R (FGM), and KetacTM Universal HM (3M ESPE); after 24 hours, 7 days and 60 days after the mixing process. Materials and methods: Three high-viscosity glass ionomer cements were selected for the present in vitro study: KetacTM Molar Easymix (3M ESPE), Gc Fuji IX GP, GC EQUIATM Fil (Gc corporation), and also two conventional glass ionomer cements: Maxxion R (FGM), and KetacTM Universal HM (3M ESPE), recommended for the Atraumatic Restorative Treatment (ART). The mixing process was performed strictly respecting the manufacturer recommendations. The analysis unit was made of glass ionomer cylinders of 2mm high and 4mm in diameter, prepared with a metallic matrix. 15 samples were created for each study group, obtaining a total of 225 samples. The compressive strength was evaluated by Instron® universal machine placing the specimens one by one vertically, with a speed of 1mm / min until the sample fractured, and the results were registered in MPa. Results: The encapsulated ionomer GC EQUIATM Fil (Gc corporation) showed higher values of compressive strength at 24 hours (299.80 MPa), while at 7 and 60 days it was KetacTM Universal HM (3M ESPE), 77.04 MPa and 75.48 MPa, respectively. On the other hand, there are significant differences in the comparison of each glass ionomer cement in the three evaluation times. As well as, there are significant differences in the three times evaluated: 24 hours: GC EQUIATM Fil (Gc corporation), at 7 and 60 days KetacTM Universal HM (3M ESPE). Conclusion: The encapsulated ionomer GC EQUIATM Fil (Gc corporation) showed higher values of compressive strength at 24 hours. There are significant differences in the comparison of each glass ionomer cement over the three times, also at each evaluation time: 24 hours: GC EQUIATM Fil (Gc corporation), at 7 and 60 days KetacTM Universal HM (3M ESPE). / Tesis
2

Comparación del ángulo de convergencia en dientes preparados para coronas según la clínica cursada por estudiantes de odontología de la Universidad Peruana de Ciencias Aplicadas (UPC)

Guevara Álvarez, Maricarmen 03 June 2016 (has links)
El propósito de este estudio fue comparar el ángulo de convergencia (AC) en dientes preparados para coronas según el ciclo académico por estudiantes de Odontología de la Universidad Peruana de Ciencias Aplicadas (UPC). 76 alumnos de 7mo a 10mo ciclo prepararon 152 piezas dentarias entre incisivos y premolares, para recibir una corona metal cerámica. Se capturaron las imágenes de las caras vestibulolingual (VL) y mesiodistal (MD) de los dientes preparados y se midió el AC de dichas caras con la ayuda del software AutoCAD (Autodesk). Se halló una diferencia significativa (p= 0.003) en la pieza 21 en la cara VL, debido a la posición de la pieza en la cavidad oral, visión indirecta y habilidad del operador. El mayor promedio de AC en la pieza 21 fue en la cara VL y MD con 25.27 º + 8.47 y 15.81 º + 4.23 respectivamente. Por otro lado, para la pieza 24 en la VL y MD fue de 14.83 º y 17.45 º respectivamente. No hubo gran diferencia entre los AC de las demás piezas talladas. / The aim of this study was to compare the convergence angle in teeth prepared for crowns for students of School of Dentistry Peruvian University of Applied Sciences (UPC). 76 students in 7th to 10th cycle prepared 152 dental pieces between incisors and premolars, to receive a ceramic metal crown. The images of the vestibulolingual (VL) and mesiodistal (MD) faces of the prepared teeth were measured and the AC of said faces was measured with the aid of AutoCAD software (Autodesk). A significant difference (p = 0.003) was found in part 21 on the VL face, due to the position of the piece in the oral cavity, indirect vision and operator ability. The highest average AC in piece 21 was in the face VL and MD with 25.27 º + 8.47 and 15.81 º + 4.23 respectively. On the other hand, for piece 24 in the VL and MD was 14.83 º and 17.45 º respectively. There was no great difference between the AC of the other carved pieces.
3

Evaluación clínica de 6 meses de restauraciones clase i de resina compuesta en la clínica docente UPC

Arnáez Talavera, Daniela 03 November 2016 (has links)
Objetivo: Evaluar el comportamiento clínico de las resinas compuestas clase I realizadas por alumnos de pregrado en la Clínica Docente UPC después de 6 meses. Materiales y métodos: Se evaluaron, luego de 6 meses, 47 resinas Clase I. Se utilizó la metodología USPHS, describiendo el color, adaptación marginal, rugosidad, tinción marginal, forma anatómica y caries secundaria mediante la codificación Alfa, Bravo y Charlie, es decir, restauraciones en condición excelente, aceptable e inaceptable respectivamente. Resultados: Los pacientes fueron contactados a los 6 meses de haber realizado las restauraciones Clase I. Se encontró que el 100% de las restauraciones se mantuvieron iguales. Al no presentarse variación alguna durante ese periodo, se concluye que tanto en la medida del baseline como en la comparativa a los 6 meses se obtuvo Alfa al 100% (n = 47) para el color, adaptación marginal, rugosidad, tinción marginal y caries secundaria; y se obtuvo Alfa al 87.23% (n = 41) y Bravo al 12.77% (n = 6), para la forma anatómica. Conclusión: Para la evaluación clínica de 6 meses de restauraciones Clase I de resina compuesta, las restauraciones mantuvieron el 100% de similitud durante ese periodo de tiempo, es decir tanto en la medida del baseline como en la comparativa. / Objective: The aim of this study was to evaluate the clinical performance Class I composites performed by undergraduate students at the Teaching Clinic UPC after 6 months. Material and Methods: A total of 47 class I restorations were clinically evaluated 6 months after placement, using USPHS criteria, describing color match, marginal adaptation, roughness, marginal staining, anatomy and secondary caries. Alpha, Bravo and Charlie where the coding, being excellent restorations, acceptable and unacceptable condition respectively. Results: At the 6-month follow-up, all restorations received the same initial scores with respect to each evaluation criterion. Color match, marginal adaptation, roughness, marginal staining and secondary caries scored Alfa at 100% (n = 47), and anatomical shape scored Alfa at 87.23 % (n = 41) and Bravo at 12.77 % (n = 6). Conclusion: All composites were clinically functional after 6 month and received the same initial scores with respect to each evaluation criterion. / Tesis
4

Comparación in vitro de la precisión dimensional de dos técnicas de impresión

Céspedes Brea, Bárbara Alisson 26 June 2017 (has links)
Objetivo: Comparar in vitro la precisión dimensional de la silicona por condensación mediante la técnica de impresión de doble mezcla; de doble impresión con alivio del margen y doble impresión con alivio total. Materiales y métodos: Las muestras estuvieron conformadas por 42 impresiones utilizando silicona por condensación Putty- Spedeex de un modelo maestro de acero inoxidable, el cual presentó dos pilares homogéneos que simularon la preparación para una corona. Estas muestras se dividieron en 3 grupos según la técnica de impresión (doble mezcla, doble impresión con alivio del margen y doble impresión con alivio total). Para determinar la precisión dimensional de los modelos definitivos en comparación al modelo maestro, se realizaron 7 mediciones (MD1, MD2, VL1, VL2, AL1, AL2, DI) con una máquina especializada en coordenadas, modelo Contura G2 con tecnología de Scanning por contacto ZEISS. Se realizaron las pruebas estadísticas Kruskal-Wallis y U de Mann-Whitney. Resultados: Se encontraron diferencias estadísticamente significativas (p˂0.001) en las medidas MD1, MD2, AL2 al comparar las 3 técnicas de impresión con el modelo maestro. La técnica de doble impresión con alivio total presentó una mayor cantidad de medidas (MD1, MD2, VL1, AL1, DI) que no mostraron diferencias estadísticamente significativas (p<0.005) en comparación al modelo maestro. Conclusiones: La técnica de doble impresión con alivio total presentó mayor precisión dimensional que las técnicas de doble mezcla y la técnica de doble impresión con alivio del margen utilizando silicona de condensación. / Objective: Compare in vitro the dimensional precision of the polivinil siloxano using the technique of impression of double mixture; double impression with margin relief and double impression with total relief. Materials and methods: The samples were composed of 42 impressions using Putty-Spedeex polivinil siloxano from a master stainless steel model, which presented two homogeneous pillars that simulated the preparation for a crown. These samples were divided into 3 groups according to the printing technique (double mix, double impression with margin relief and double impression with total relief). In order to determine the dimensional accuracy of the final models in comparison to the master model, 7 measurements (MD1, MD2, VL1, VL2, AL1, AL2, DI) were performed with a coordinated machine, Contura G2 model with contact scanning technology ZEISS. Statistical tests were performed Kruskal-Wallis and U of Mann-Whitney. Results: Statistically significant differences (p˂0.001) were found in measures MD1, MD2, AL2 when comparing the three printing techniques with the master model. The double impression technique with total relief presented a greater number of measures (MD1, MD2, VL1, AL1, DI) than did not show statistically significant differences (p <0.005) in comparison to the master model. Conclusions: The technique of double impression with total relief presented greater dimensional accuracy than the techniques of double mixing and the technique of double impression with relief of the margin using silicone of condensation.

Page generated in 0.1104 seconds