• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 11
  • 9
  • 9
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da reprodutibilidade de medidas obtidas com o uso de perineômetro no período gestacional / Evaluation of the reproducibility of measurements obtained with the use of perineometer during pregnancy

Ribeiro, Juliana dos Santos 18 March 2014 (has links)
O objetivo primário deste estudo foi avaliar a reprodutibilidade inter-examinador, na mensuração da pressão intravaginal em gestantes. Participaram do estudo 41 gestantes baixo risco com capacidade de contrair voluntariamente os MAP. Os MAP (músculos do assoalho pélvico) foram avaliados quanto a sua capacidade de contração por meio da palpação vaginal , e em seguida com uso do perineômetro Peritron®. Foram realizadas três contrações máximas com intervalo de descanso entre cada contração de 10 segundos. As avaliações foram realizadas por dois examinadores distintos e cegos em relação aos resultado da avaliação do outro, em dois dias alternados, com intervalo entre as avaliações de 2 a 7 dias, mantendo o mesmo horário entre as avaliações. As gestantes tinham idade entre 18 e 41 anos (26,07±5,69), índice de massa corpórea (IMC) entre 18,32 e 43,43 Kg/m² (26,46±5,77), com paridade entre 0 e 8 partos (1,09±1,65). Na análise estatística foi utilizado Coeficiente de Correlação de Concordância (CCC) para as medidas entre avaliadores e os limites de concordância de Bland e Altman foram utilizados para observar a concordância. Para medir a reprodutibilidade intra-sessão das três medidas para cada avaliador foi utilizado o Coeficiente de Correlação Intraclasse (ICC). Os resultados foram interpretados de acordo com a seguinte classificação: valores abaixo de 0,50 foram considerados de reprodutibilidade pobre, valores 0,50 a 0,75 foram considerados como moderada reprodutibilidade e valores acima de 0,75 foram considerados de boa reprodutibilidade. Foram encontradas boa concordância nas medidas interexaminadores entre os valores da média do pico no período gestacional (0,81) e essa concordância também ocorreu quando os trimestres foram analisados distintamente (0,81, 0,78, 0,86 para primeiro, segundo e terceiro trimestre respectivamente). Quanto a variável pico de contração os resultados mostraram uma concordância que variou de moderada à boa, para a análise das aferições separadamente, com valores que variaram de 0,54 à 0,88. Já as variáveis média e duração da contração apresentaram valores irregulares. A reprodutibilidade das medidas intra-sessão para a variável pico, para o primeiro, segundo, terceiro trimestre gestacional e para o período gestacional geral mostraram valores de concordância moderada para o avaliador 1 (0,72, 0,75, 0,78, 0,74 respectivamente) e valores de forte concordância para o avaliador 2 (0,95, 0,93, 0,97, 0,94 respectivamente). O presente estudo concluiu que o perineômetro é um método com boa reprodutibilidade inter-examinador para avaliar os músculos do assoalho pélvico (MAP) durante o período gestacional, quando as variáveis de média do pico da contração e pico da contração são utilizadas. Esse estudo não encontrou diferença entre os trimestres gestacionais, sugerindo que a reprodutibilidade da média do pico de contração e pico de contração do AP utilizando-se o perineometro Peritron é variável de moderada a boa. / The primary objective of this study was to evaluate the inter-examiner reproducibility in the measurement of intravaginal pressure in pregnant women. The study included 41 low-risk pregnant women. The ability to contract PFM (pelvic floor muscles) was assessed using vaginal palpation and the PFM strength was measured using the perineometer Peritron. Three maximal contractio ns were performed with an interval of rest between each contraction of 10 seconds. The evaluations were performed by two different examiners who were blinded to each evaluation result of the other, on two alternate days, with an interval between assessment s 2-7 days keeping the same time between assessments. The women were aged between 18 and 41 years (26.07 ± 5.69), body mass index (BMI) between 18.32 and 43.43 kg / m² (26.46 ± 5.77), with parity 0 births and 8 (1.09 ± 1.65). For statistical analysis we used the concordance correlation coefficient (CCC) for measurements between examiners. Bland and Altman limits of agreement was used in the analysis. To measure the intra-session reproducibility of the three measures for each examiner the intraclass correlation coefficient (ICC) was used. The results were interpreted according to the following classification: values below 0.50 were considered poor reproducibility, values from 0.50 to 0.75 were considered moderate reproducibility and values above 0.75 were considered good reproducibility. It was found a good concordance of inter-examiner between the values of mean peak during pregnancy (0.81) and this correlation also occurred when the gestational trimesters were analyzed distinctly (0.81, 0.78, 0.86 for first, second and third trimester respectively). As for variable peak contraction results showed a concordance ranging from moderate to good, for the analysis of the measurements separately, with values ranging from 0.54 to 0.88. The average and durati on of contractions showed irregular values . The reproducibility of intra-session measures for the variable peak, for the first, second, and third trimester of pregnancy for general values showed moderate agreement for evaluator 1 (0.72, 0.75, 0.78, 0 , 74 respectively) and values of concordance for evaluator 2 (0.95, 0.93, 0.97, 0.94 respectively). This study concluded that perineometer is a method with good reproducibility inter -examiner to evaluate the pelvic floor muscles during pregnancy, when th e variables of mean peak contraction and peak contraction are used. This study found no difference between gestational trimesters, suggesting that interrater reproducibility of of mean peak contraction and peak contraction of PFM using Peritron perineomet er is variable from moderate to good.
2

Validade e confiabilidade das vers?es original e curta da escala Activities-Specific Balance Confidence (ABC-16 e ABC-6) para idosos brasileiros residentes na comunidade

Freitas, Raysa Vanessa de Medeiros 16 February 2018 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-04-02T15:20:07Z No. of bitstreams: 1 RaysaVanessaDeMedeirosFreitas_DISSERT.pdf: 1441664 bytes, checksum: 48e9822af12723aec191fe48069617d7 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-04-06T11:41:38Z (GMT) No. of bitstreams: 1 RaysaVanessaDeMedeirosFreitas_DISSERT.pdf: 1441664 bytes, checksum: 48e9822af12723aec191fe48069617d7 (MD5) / Made available in DSpace on 2018-04-06T11:41:38Z (GMT). No. of bitstreams: 1 RaysaVanessaDeMedeirosFreitas_DISSERT.pdf: 1441664 bytes, checksum: 48e9822af12723aec191fe48069617d7 (MD5) Previous issue date: 2018-02-16 / Introdu??o: a confian?a no equil?brio ? definida como ?a habilidade de um indiv?duo de manter o equil?brio durante a realiza??o das atividades de vida di?ria? e ? afetada pelas cren?as pessoais. Portanto, um sujeito que relata uma baixa confian?a no equil?brio pode apresentar pior desempenho do equil?brio postural. Uma das ferramentas mais utilizadas para quantificar a confian?a no equil?brio de indiv?duos da comunidade ? a escala Activities-specific Balance Confidence (ABC), tanto na vers?o original (ABC-16) quanto na vers?o curta (ABC-6). A escala ABC foi traduzida e adaptada para a popula??o de idosos brasileiros. Entretanto, o estudo de suas propriedades psicom?tricas ainda se faz necess?rio, al?m da defini??o de pontos de corte capazes de diferenciar idosos com e sem d?ficits no equil?brio postural. Objetivos: avaiar as propriedades psicom?tricas das escalas ABC-16 e ABC-6 e determinar pontos de corte capazes de diferencias idosos comunit?rios com d?ficits no equil?brio postural. M?todos: trata-se de um estudo metodol?gico que seguiu as recomenda??es do Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) realizado de abril a novembro de 2017. O n?vel de confian?a no equil?brio foi avaliado pela ABC-16 e ABC-6. Para mensurar a confiabilidade interobservador, duas avalia??es foram realizadas por avaliadores distintos com 30 minutos de intervalo entre elas. Ap?s uma semana, um dos avaliadores reaplicou a escala para verificar a confiabilidade intraobservador. A ordem dos avaliadores foi determinada aleatoriamente. Um terceiro avaliador aferiu o equil?brio postural dos indiv?duos por meio da Escala de Equil?brio de Berg (EEB), as quatro condi??es do modified Clinical Test of Sensory Interaction and Balance (mCTSIB) e o teste de Apoio Unipodal (AU); o medo de cair por meio da Falls Efficacy Scale-International (FES-I), e a mobilidade por meio do teste de caminha de 4 metros (TC4m). O teste de correla??o de Spearman foi utilizado para determinar as validades de construto e crit?rio das escalas ABC-16 e ABC-6. A consist?ncia interna das escalas foi avaliada por meio do coeficiente ? de Cronbach, enquanto que as confiabilidades das escalas ABC-16 e ABC-6 foram mensuradas pelo Coeficiente de Correla??o Intraclasse (CII). Uma an?lise de regress?o linear foi utilizada para identificar as poss?veis vari?veis preditoras da confian?a no equil?brio e o teste de Mann-Whitney foi adotado para testar as diferen?as entre os sexos e entre os idosos com e sem queixas de tontura. Resultados: as escalas ABC-16 e ABC-6 mostraram uma correla??o estatisticamente significativa com a maioria das medidas de equil?brio postural, com a FES-I e o TC4m. A escala ABC-6 tamb?m apresentou correla??o estatisticamente significativa com o padr?o ouro para confian?a no equil?brio, a escala ABC-16 (r=0.958, p<0,001). A consist?ncia interna pelo ? de Cronbach da ABC-16 e da ABC-6 foi de 0.943 e 0.901, respectivamente. Para a ABC-6, observou-se confiabilidades intra e interexaminador de ICC=0.956 e ICC=0.946, respectivamente. J? para a escala ABC-16, encontramos confiabilidades intra e interexaminador de 0.972 e 0.968, respectivamente. A curva Receiver Operating Characteristics (ROC) indicou um valor de ?67% como o melhor ponto de corte para identificar idosos com d?ficits no equil?brio na escala ABC-16 (sensibilidade: 81%; especificidade: 77.4%), e ?44% (sensibilidade: 87.5%; especificidade: 82.1%) na escala ABC-6. Conclus?o: tanto a escala ABC-16 quanto a ABC-6 apresentam, no geral, uma boa validade, e excelentes confiabilidades intra e interobservador e consist?ncia interna. Portanto, estas escalas s?o adequadas para a avalia??o da confian?a no equil?brio de idosos brasileiros residentes na comunidade. Al?m disso, os pontos de corte para as escalas encontrados podem ser ?teis no rastreio de idosos residentes na comunidade com d?ficits no equil?brio postural e maior risco de cair. / Introduction: Balance confidence is described as ?a person?s ability to maintain balance while performing activities of daily living? and is affected by an individual?s beliefs. Therefore, an individual who report a low confidence in balance may present lower postural balance performances. One of the most used tools to quantify the balance confidence of the community-dwelling individual is the Activities-specific Balance Confidence (ABC) scale, in its original (ABC-16) and short (ABC-6) versions. The ABC scale was translated and adapted to the Brazilian older adults. However, the study of the psychometric properties is still required and also cut-off points for both scales have not been provided yet. Objectives: To investigate the psychometric properties of the ABC-16 and ABC-6, and to determine cut-off points capable to identity community-dwelling older adults with deficits in postural balance and higher risk of falling. Methods: This is a psychometric study that followed the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN). This study took place from April 2017 to November 2017. The level of balance confidence was assessed by the ABC-16 and ABC-6. To assess the interrater reliability, two evaluations with a 30-minute interval was performed by distinct evaluators. After one week, one of the evaluators re-applied the ABC-16 to verify the intrarater reliability. The order of the evaluators was chosen randomly. A third examiner assessed the postural balance of the individuals through the Berg Balance Scale (BBS), the modified Clinical Test of Sensory Interaction on Balance (mCTSIB) and the Unilateral Stance (US), the fear of falling through the Falls Efficacy Scale-International (FES-I), and mobility through the 4-m walk test (4MWT). Results: The ABC-16 and ABC-6 showed a statistically significant correlation with most of the measures of postural balance, FES-I and 4MWT. The ABC-6 also presented statistically significant correlation with the gold standard, the ABC-16 (r=0.958, p<0,001). The internal consistency analysis of the ABC-16 and ABC-6 yielded a Cronbach?s ? value 0.943 and 0.901, respectively. Both ABC-16 and ABC-6 presented excellent intra and interrater reliability. The Receiver Operating Characteristics (ROC) curve indicated a value of ?67% as the best cut-off point to identify older adults with balance impairments in the ABC-16 (sensitivity: 81%; specificity: 77.4%), and ?44% (sensitivity: 87.5%; specificity: 82.1%) in the ABC-6. Conclusion: Both ABC-16 and ABC-6 have an overall good validity, and excellent internal consistency, and intra and inter-rater reliability. Therefore, these scales are suitable tools for assessing balance confidence in the Brazilian community-dwelling elderly people.
3

Avaliação da reprodutibilidade de medidas obtidas com o uso de perineômetro no período gestacional / Evaluation of the reproducibility of measurements obtained with the use of perineometer during pregnancy

Juliana dos Santos Ribeiro 18 March 2014 (has links)
O objetivo primário deste estudo foi avaliar a reprodutibilidade inter-examinador, na mensuração da pressão intravaginal em gestantes. Participaram do estudo 41 gestantes baixo risco com capacidade de contrair voluntariamente os MAP. Os MAP (músculos do assoalho pélvico) foram avaliados quanto a sua capacidade de contração por meio da palpação vaginal , e em seguida com uso do perineômetro Peritron®. Foram realizadas três contrações máximas com intervalo de descanso entre cada contração de 10 segundos. As avaliações foram realizadas por dois examinadores distintos e cegos em relação aos resultado da avaliação do outro, em dois dias alternados, com intervalo entre as avaliações de 2 a 7 dias, mantendo o mesmo horário entre as avaliações. As gestantes tinham idade entre 18 e 41 anos (26,07±5,69), índice de massa corpórea (IMC) entre 18,32 e 43,43 Kg/m² (26,46±5,77), com paridade entre 0 e 8 partos (1,09±1,65). Na análise estatística foi utilizado Coeficiente de Correlação de Concordância (CCC) para as medidas entre avaliadores e os limites de concordância de Bland e Altman foram utilizados para observar a concordância. Para medir a reprodutibilidade intra-sessão das três medidas para cada avaliador foi utilizado o Coeficiente de Correlação Intraclasse (ICC). Os resultados foram interpretados de acordo com a seguinte classificação: valores abaixo de 0,50 foram considerados de reprodutibilidade pobre, valores 0,50 a 0,75 foram considerados como moderada reprodutibilidade e valores acima de 0,75 foram considerados de boa reprodutibilidade. Foram encontradas boa concordância nas medidas interexaminadores entre os valores da média do pico no período gestacional (0,81) e essa concordância também ocorreu quando os trimestres foram analisados distintamente (0,81, 0,78, 0,86 para primeiro, segundo e terceiro trimestre respectivamente). Quanto a variável pico de contração os resultados mostraram uma concordância que variou de moderada à boa, para a análise das aferições separadamente, com valores que variaram de 0,54 à 0,88. Já as variáveis média e duração da contração apresentaram valores irregulares. A reprodutibilidade das medidas intra-sessão para a variável pico, para o primeiro, segundo, terceiro trimestre gestacional e para o período gestacional geral mostraram valores de concordância moderada para o avaliador 1 (0,72, 0,75, 0,78, 0,74 respectivamente) e valores de forte concordância para o avaliador 2 (0,95, 0,93, 0,97, 0,94 respectivamente). O presente estudo concluiu que o perineômetro é um método com boa reprodutibilidade inter-examinador para avaliar os músculos do assoalho pélvico (MAP) durante o período gestacional, quando as variáveis de média do pico da contração e pico da contração são utilizadas. Esse estudo não encontrou diferença entre os trimestres gestacionais, sugerindo que a reprodutibilidade da média do pico de contração e pico de contração do AP utilizando-se o perineometro Peritron é variável de moderada a boa. / The primary objective of this study was to evaluate the inter-examiner reproducibility in the measurement of intravaginal pressure in pregnant women. The study included 41 low-risk pregnant women. The ability to contract PFM (pelvic floor muscles) was assessed using vaginal palpation and the PFM strength was measured using the perineometer Peritron. Three maximal contractio ns were performed with an interval of rest between each contraction of 10 seconds. The evaluations were performed by two different examiners who were blinded to each evaluation result of the other, on two alternate days, with an interval between assessment s 2-7 days keeping the same time between assessments. The women were aged between 18 and 41 years (26.07 ± 5.69), body mass index (BMI) between 18.32 and 43.43 kg / m² (26.46 ± 5.77), with parity 0 births and 8 (1.09 ± 1.65). For statistical analysis we used the concordance correlation coefficient (CCC) for measurements between examiners. Bland and Altman limits of agreement was used in the analysis. To measure the intra-session reproducibility of the three measures for each examiner the intraclass correlation coefficient (ICC) was used. The results were interpreted according to the following classification: values below 0.50 were considered poor reproducibility, values from 0.50 to 0.75 were considered moderate reproducibility and values above 0.75 were considered good reproducibility. It was found a good concordance of inter-examiner between the values of mean peak during pregnancy (0.81) and this correlation also occurred when the gestational trimesters were analyzed distinctly (0.81, 0.78, 0.86 for first, second and third trimester respectively). As for variable peak contraction results showed a concordance ranging from moderate to good, for the analysis of the measurements separately, with values ranging from 0.54 to 0.88. The average and durati on of contractions showed irregular values . The reproducibility of intra-session measures for the variable peak, for the first, second, and third trimester of pregnancy for general values showed moderate agreement for evaluator 1 (0.72, 0.75, 0.78, 0 , 74 respectively) and values of concordance for evaluator 2 (0.95, 0.93, 0.97, 0.94 respectively). This study concluded that perineometer is a method with good reproducibility inter -examiner to evaluate the pelvic floor muscles during pregnancy, when th e variables of mean peak contraction and peak contraction are used. This study found no difference between gestational trimesters, suggesting that interrater reproducibility of of mean peak contraction and peak contraction of PFM using Peritron perineomet er is variable from moderate to good.
4

Confiabilidade do limiar térmico doloroso por meio do Quantitative Sensory Testing e suas correlações sobre pontos gatilhos miofasciais em indivíduos com dor cervical crônica / Reliability of the thermal pain threshold with Quantiative Sensory Testing and its correlations on myofascial trigger points in individuals with chronic neck pain

Alessandra Kelly de Oliveira 19 April 2017 (has links)
A dor cervical encontra-se entre as disfunções musculoesqueléticas mais prevalentes e estima-se que metade das pessoas que apresentam cervicalgia desenvolvam sintomas crônicos, sendo encaminhados para serviços de reabilitação. Entre as estruturas anatômicas envolvidas no processo patológico da cervicalgia destaque-se o componente miofascial. A dor miosfascial pode conduzir a um distúrbio psicofisiológico envolvendo sistemas centrais reguladores de dor do sistema nervoso, resultando em respostas fisiológicas. Em relação a avaliação da dor miofascial, destacase o uso do Quantitative Sensory Testing (QST) definido como um conjunto de métodos capaz de avaliar as sensações transmitidas pelas fibras sensoriais, entretanto, ainda se faz necessário o respaldo científico quanto à confiabilidade desse instrumento na população com pontos gatilhos em dor cervical crônica. O objetivo deste estudo foi avaliar a confiabilidade intra e interexaminador do QST para avaliação do limiar térmico doloroso sobre pontos gatilhos miofasciais no músculo trapézio fibras descendentes de indivíduos que apresentam cervicalgia crônica e sua correlação com outros instrumentos de avaliação da dor. Foram inseridos 30 voluntários de ambos os gêneros, com faixa etária de 18 e 45 anos que apresentaram ponto gatilho miofascial bilateralmente, ativos e centrais no músculo trapézio fibras descendentes. Foram realizadas duas coletas por cada avaliador com um intervalo de uma semana entre elas, sendo empregadas na avaliação a Escala Numérica de Dor, Neck Disability Index, algometria, Escala de Pensamentos Catastróficos sobre Dor, termografia infravermelha e o QST. A análise dos dados apresentou valores de ICC intra-examinador variaram entre 0,876 e 0,896 e, os valores de ICC inter-examinador variaram 0,917 e 0,954. Assim, constatou-se no presente estudo moderada confiabilidade para a análise intraexaminador enquanto a avaliação inter-examinador apresentou excelente confiabilidade. Em relação às correlações, foram observadas associações significativas, entre a intensidade de dor e limiar térmico doloroso (calor), sendo fraca e negativa à direita; ente a intensidade de dor e limiar térmico doloroso (frio) , sendo fraca e positiva à direita e a esquerda. Com os demais instrumentos de avaliação, não foram observadas correlações significativas. Conclui-se que a mensuração do limiar térmico doloroso sobre pontos gatilhos miofasciais em indivíduos com cervicalgia crônica apresenta valores de confiabilidade aceitáveis respaldando o emprego do QST para a avaliação em pesquisas e no ambiente clínico, no entanto a sua associação com outros instrumentos de avaliação da dor são fracos ou inexistentes. / Neck pain is one of the most prevalent musculoskeletal disorders and it is estimated that half of the people with this disorder develop chronic symptoms and are referred to rehabilitation services. A lot of anatomical structures are involved in the pathological process of the neck pain with a focus on the myofascial component. Myofascial pain can lead to a psychophysiological disorder involving central nervous system pain regulators, resulting in physiological responses. Concerning the evaluation of myofascial pain the use of Quantitative Sensory Testing (QST) which is defined as a set of methods capable of evaluating the sensations transmitted by the sensory fibers has been highlighted, however, it is still necessary the scientific support about the reliability of this instrument in the population with trigger points in chronic neck pain. The objective of this study was to evaluate the intra and inter-rater reliability of the QST for assessing the pain threshold on myofascial triggers in the trapezius muscle fibers of individuals with chronic neck pain and their correlation with other pain assessment instruments. A total of 30 volunteers of both genders, aged 18 and 45 years, who presented myofascial trigger point bilaterally, active and central in the trapezius muscle were included. Two examinations were carried out for each evaluator with an interval of one week between them, using Numerical Pain Scale, Neck Disability Index, Algometry, Catastrophic Thoughts on Pain Scale, infrared thermography and QST. Data analysis showed intra-examiner ICC values ranged from 0.876 to 0.896 and interexaminer ICC values ranged from 0.917 to 0.954. Thus, the present study showed moderate reliability for the intra-examiner analysis while the inter-examiner evaluation presented excellent reliability. Regarding the correlations there were significant associations between pain intensity and pain threshold (heat) being weak and negative on the right, pain intensity and pain threshold (cold) being weak and positive on the right and left. With the other instruments evaluation, no significant correlations were observed. It is concluded that the measurement of the pain threshold on myofascial trigger points in individuals with chronic neck pain presents acceptable reliability values supporting the use of QST for evaluation in research and clinical settings, however, its association with other pain assessment instruments are weak or nonexistent.
5

Confiabilidade do limiar térmico doloroso por meio do Quantitative Sensory Testing e suas correlações sobre pontos gatilhos miofasciais em indivíduos com dor cervical crônica / Reliability of the thermal pain threshold with Quantiative Sensory Testing and its correlations on myofascial trigger points in individuals with chronic neck pain

Oliveira, Alessandra Kelly de 19 April 2017 (has links)
A dor cervical encontra-se entre as disfunções musculoesqueléticas mais prevalentes e estima-se que metade das pessoas que apresentam cervicalgia desenvolvam sintomas crônicos, sendo encaminhados para serviços de reabilitação. Entre as estruturas anatômicas envolvidas no processo patológico da cervicalgia destaque-se o componente miofascial. A dor miosfascial pode conduzir a um distúrbio psicofisiológico envolvendo sistemas centrais reguladores de dor do sistema nervoso, resultando em respostas fisiológicas. Em relação a avaliação da dor miofascial, destacase o uso do Quantitative Sensory Testing (QST) definido como um conjunto de métodos capaz de avaliar as sensações transmitidas pelas fibras sensoriais, entretanto, ainda se faz necessário o respaldo científico quanto à confiabilidade desse instrumento na população com pontos gatilhos em dor cervical crônica. O objetivo deste estudo foi avaliar a confiabilidade intra e interexaminador do QST para avaliação do limiar térmico doloroso sobre pontos gatilhos miofasciais no músculo trapézio fibras descendentes de indivíduos que apresentam cervicalgia crônica e sua correlação com outros instrumentos de avaliação da dor. Foram inseridos 30 voluntários de ambos os gêneros, com faixa etária de 18 e 45 anos que apresentaram ponto gatilho miofascial bilateralmente, ativos e centrais no músculo trapézio fibras descendentes. Foram realizadas duas coletas por cada avaliador com um intervalo de uma semana entre elas, sendo empregadas na avaliação a Escala Numérica de Dor, Neck Disability Index, algometria, Escala de Pensamentos Catastróficos sobre Dor, termografia infravermelha e o QST. A análise dos dados apresentou valores de ICC intra-examinador variaram entre 0,876 e 0,896 e, os valores de ICC inter-examinador variaram 0,917 e 0,954. Assim, constatou-se no presente estudo moderada confiabilidade para a análise intraexaminador enquanto a avaliação inter-examinador apresentou excelente confiabilidade. Em relação às correlações, foram observadas associações significativas, entre a intensidade de dor e limiar térmico doloroso (calor), sendo fraca e negativa à direita; ente a intensidade de dor e limiar térmico doloroso (frio) , sendo fraca e positiva à direita e a esquerda. Com os demais instrumentos de avaliação, não foram observadas correlações significativas. Conclui-se que a mensuração do limiar térmico doloroso sobre pontos gatilhos miofasciais em indivíduos com cervicalgia crônica apresenta valores de confiabilidade aceitáveis respaldando o emprego do QST para a avaliação em pesquisas e no ambiente clínico, no entanto a sua associação com outros instrumentos de avaliação da dor são fracos ou inexistentes. / Neck pain is one of the most prevalent musculoskeletal disorders and it is estimated that half of the people with this disorder develop chronic symptoms and are referred to rehabilitation services. A lot of anatomical structures are involved in the pathological process of the neck pain with a focus on the myofascial component. Myofascial pain can lead to a psychophysiological disorder involving central nervous system pain regulators, resulting in physiological responses. Concerning the evaluation of myofascial pain the use of Quantitative Sensory Testing (QST) which is defined as a set of methods capable of evaluating the sensations transmitted by the sensory fibers has been highlighted, however, it is still necessary the scientific support about the reliability of this instrument in the population with trigger points in chronic neck pain. The objective of this study was to evaluate the intra and inter-rater reliability of the QST for assessing the pain threshold on myofascial triggers in the trapezius muscle fibers of individuals with chronic neck pain and their correlation with other pain assessment instruments. A total of 30 volunteers of both genders, aged 18 and 45 years, who presented myofascial trigger point bilaterally, active and central in the trapezius muscle were included. Two examinations were carried out for each evaluator with an interval of one week between them, using Numerical Pain Scale, Neck Disability Index, Algometry, Catastrophic Thoughts on Pain Scale, infrared thermography and QST. Data analysis showed intra-examiner ICC values ranged from 0.876 to 0.896 and interexaminer ICC values ranged from 0.917 to 0.954. Thus, the present study showed moderate reliability for the intra-examiner analysis while the inter-examiner evaluation presented excellent reliability. Regarding the correlations there were significant associations between pain intensity and pain threshold (heat) being weak and negative on the right, pain intensity and pain threshold (cold) being weak and positive on the right and left. With the other instruments evaluation, no significant correlations were observed. It is concluded that the measurement of the pain threshold on myofascial trigger points in individuals with chronic neck pain presents acceptable reliability values supporting the use of QST for evaluation in research and clinical settings, however, its association with other pain assessment instruments are weak or nonexistent.
6

Toracometria em crianças com distrofia muscular de Duchenne: refinamento de metodologia de avaliação / Thoracic cirtometry in children Duchenne muscular distrophy: refinement of evaluation methodology

Garcia Junior, Agenor 02 February 2012 (has links)
Contextualização: A toracometria é uma técnica simples e acessível para avaliar mobilidade do tórax durante respiração forçada, mas não permite analisar os movimentos compensatórios utilizados por portadores de doenças crônicas, como a distrofia muscular de Duchenne (DMD), caracterizada pela degeneração progressiva e irreversível da musculatura esquelética. Objetivos: Ampliar a técnica de toracometria, permitindo avaliação das compensações posturais, analisar a confiabilidade da ferramenta e, descrever a mobilidade torácica de crianças com DMD, durante respiração profunda. Métodos: Participaram 60 meninos, 30 com DMD (10,1±0,5 anos) e 30 saudáveis (9,5±0,6 anos). Aplicou-se a técnica de toracometria expandida em duas fases: livre movimentação corporal, permitindo avaliação de compensações posturais (toracometria livre) e, bloqueio de movimentos compensatórios, facilitando análise de movimentos do gradil costal (toracometria dirigida). Esta técnica prevê filmagem e observação sistemática dos movimentos, gerando dados numéricos e descritivos permanentes. O estudo de confiabilidade da técnica foi realizado nos dois grupos. Resultados: As medidas de toracometria axial e xifóide (livre e dirigida) apresentaram excelente confiabilidade intra e interexaminadores. As medidas coletadas apresentaram diferenças significantes entre os grupos. Nas crianças com DMD, a toracometria livre apresentou valor de expansibilidade torácica maior, mostrando que as compensações facilitam a mobilidades da caixa torácica. A técnica de toracometria livre apresentada permitiu a descrição de compensações posturais, sendo que as observadas com maior frequência foram os movimentos associados de cabeça, ombro e tórax. Conclusões: A técnica de toracometria expandida apresentou excelente confiabilidade e permitiu descrever os movimentos do tórax e dos arcos costais. Sugere-se sua utilização na avaliação respiratória de crianças com DMD / Background: Thoracic cirtometry is a simple and accessible technique to assess chest mobilization during forced breathing, but does not allow to analyze compensatory movements commonly used by people with chronic diseases, such Duchenne muscular dystrophy (DMD), characterized by progressive degeneration of musculoskeletal system. Objectives: To expand the technique of thoracic cirtometry to allow assessment compensatory movements, to analyze the reliability of the tool and to describe thoracic mobility of children with DMD. Methods: Participated 60 boys, 30 with DMD (10.1 ± 0.5 years) and 30 healthy (9.5 ± 0.6 years). The expanded thoracic cirtometry was organized in two phases: body can move freely, allowing the assessment of postural compensations (free thoracic cirtometry) and with postural movements blocked, facilitating the analysis of movements of the rib cage (conducted thoracic cirtometry). This technique provides systematic observation and recording of body movements, creating descriptive and numeric permanent data. We investigated repeatability and reproducibility. Results: Measures of axial and the xiphoid thoracic cirtometry (free and conducted) showed excellent reliability. All measures showed significant differences between groups. In the DMD boys, free thoracic cirtometry presented a greater value, which probably occurs due to postural compensations. The most commons were movements of head, shoulder and chest. Conclusions: The expanded thoracic cirtometry technique showed excellent reliability and achieved the objectives of determining values related to ribs mobility during deep breath, and to describe compensatory movements. We suggested its use in respiratory evaluation of children with DMD
7

Confiabilidade inter e intraexaminador do diagn?stico de pontos-gatilho miofasciais e limiar de dor ? press?o em m?sculos do ombro

Nascimento, Jos? Diego Sales do 10 October 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-02-21T00:25:24Z No. of bitstreams: 1 JoseDiegoSalesDoNascimento_DISSERT.pdf: 1511173 bytes, checksum: ce7fedccdc99136956a48788dedf00c1 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-03-03T23:11:22Z (GMT) No. of bitstreams: 1 JoseDiegoSalesDoNascimento_DISSERT.pdf: 1511173 bytes, checksum: ce7fedccdc99136956a48788dedf00c1 (MD5) / Made available in DSpace on 2017-03-03T23:11:22Z (GMT). No. of bitstreams: 1 JoseDiegoSalesDoNascimento_DISSERT.pdf: 1511173 bytes, checksum: ce7fedccdc99136956a48788dedf00c1 (MD5) Previous issue date: 2016-10-10 / Objetivo: verificar a confiabilidade inter e intraexaminador do diagn?stico de pontos-gatilho miofasciais (PGMs) e do limiar de dor a press?o (LDP) de m?sculos do ombro, em indiv?duos assintom?ticos e sintom?ticos para s?ndrome do impacto subacromial (SIS) unilateral. Metodologia: Trata-se de um estudo de confiabilidade, composto por 52indiv?duos, 26 assintom?ticos (12 homens e 14 mulheres; 33,8?12,02 anos; IMC de 23,99 kg/m2) e 26 sintom?ticos(12 homens e 14 mulheres; 33,77?11,76 anos; IMC de 24,26 kg/m2) para SIS unilateral. Todos os indiv?duos foram avaliados bilateralmente por dois examinadores inexperientes, independentes e cegos quanto ? condi??o cl?nica do indiv?duo. Os procedimentos consistiram de avalia??o dos m?sculos do ombro quanto ? identifica??o e classifica??o de PGMs em seis m?sculos (trap?zio superior e inferior, infraespinal, supraespinal, peitoral menor e delt?ide m?dio) e LDP em seis m?sculos (trap?zio superior e inferior, infraespinal, supraespinal, delt?ide m?dio e tibial anterior), realizados no mesmo dia. Resultados: A confiabilidade intraexaminador e interexaminador de identifica??o de PGMs foi, de maneira geral, moderada a quase perfeita com porcentagem de concord?ncia (PC) >70%, nos dois grupos, com exce??o de tr?s m?sculos na avalia??o intraexaminador e quatro na interexaminador que apresentaram PC<70%, com confiabilidade entre fraca e razo?vel. Na classifica??o dos PGMs, a confiabilidade do examinador 1 foi fraca a razo?vel em 4 m?sculos, apesar do PC<70% em apenas dois m?sculos, e o examinador 2 obteve PC>70% em todos os m?sculos e confiabilidade entre boa a quase perfeita. J? a confiabilidade interexaminador de classifica??o de PGMs, esta variou entre fraca e moderada, com PC>70% em apenas um m?sculo. Para o LDP, a confiabilidade intraexaminador de ambos os examinadores foi boa ou quase perfeita (ICC: 0.73 ? 0.96) para indiv?duos assintom?ticos e sintom?ticos; a confiabilidade interexaminador foi quase perfeita (ICC: 0.85 ? 0.94) para indiv?duos assintom?ticos e entre boa e quase perfeita em sintom?ticos (ICC: 0.77 ? 0.91). Conclus?o: O estudo evidenciou uma confiabilidade intra e interexaminador aceit?vel na pr?tica cl?nica para identifica??o de PGM, independente dos m?sculos avaliados, mas vari?vel entre condi??es cl?nicas. Quanto ao LDP, a confiabilidade intra e interexaminador apresentou-se adequada para o uso em estudos cl?nicos e pr?tica cl?nica, fornecendo valores de refer?ncia para o LDP. / Objectives: To verify the interrater and intrarater reliability of the diagnosis of myofascial trigger points (MTrPs) and pressure pain threshold (PPT) in the shoulder muscles in asymptomatic individuals and individuals with symptoms of unilateral subacromial impingement syndrome (SIS). Methods: This is a reliability study, composed to 52 individuals, 26 asymptomatic (12 men and 14 women; 33,8?12,02 years old; 23,99 kg/m2 of BMI) and 26 with symptoms of unilateral SIS (12 men and 14 women; 33,77?11,76 years old; 24,26 kg/m2 of BMI). All of the individuals were evaluated by two novice raters, independent and blinded to clinical condition of the individual. The procedures consisted of evaluation the shoulder muscles for identification and classification of MTrPs in six muscles (upper trapezius, lower trapezius, infraspinatus, supraspinatus, pectoralis minor, and middle deltoid) and PPT in also six muscles (upper trapezius, lower trapezius, infraspinatus, supraspinatus, middle deltoid, and tibialis anterior), evaluated in the same day. Results: The intrarater and interrater reliability of identification of MTrPs was, generally, moderated to almost perfect with percentages of agreements (PA) >70%, in both groups, in exception of three muscles in the intrarater reliability and four muscles in the interrater reliability that presented PA<70% and reliability between slight and fair. In the classification of MTrPs, the reliability of rater 1was slight and fair in four muscles, despite the PA>70% only in two muscles; and the rater 2 obtained PA> 70% in all muscles and reliability between good almost perfect. For the interrater reliability of the classification of MTrPs, this was between slight and moderate, with PA>70% in only one muscle. About the PPT, the intrarater reliability of both raters was good or almost perfect (ICC: 0.73 ? 0.96) in asymptomatic and symptomatic individuals, the interrater reliability was almost perfect (ICC: 0.85 ? 0.94) in asymptomatic individuals and between good or almost perfect (ICC: 0.77 ? 0.91) in symptomatic individuals. Conclusion: This studyshowed acceptable intrarater and interrater reliability for clinical practicing to identification of MTrPs, independent of muscles evaluated, but variable between clinical conditions. About the PPT, the intrarater and interrater reliability presented proper to using in clinical studies and practice, providing reference values for PPT.
8

Toracometria em crianças com distrofia muscular de Duchenne: refinamento de metodologia de avaliação / Thoracic cirtometry in children Duchenne muscular distrophy: refinement of evaluation methodology

Agenor Garcia Junior 02 February 2012 (has links)
Contextualização: A toracometria é uma técnica simples e acessível para avaliar mobilidade do tórax durante respiração forçada, mas não permite analisar os movimentos compensatórios utilizados por portadores de doenças crônicas, como a distrofia muscular de Duchenne (DMD), caracterizada pela degeneração progressiva e irreversível da musculatura esquelética. Objetivos: Ampliar a técnica de toracometria, permitindo avaliação das compensações posturais, analisar a confiabilidade da ferramenta e, descrever a mobilidade torácica de crianças com DMD, durante respiração profunda. Métodos: Participaram 60 meninos, 30 com DMD (10,1±0,5 anos) e 30 saudáveis (9,5±0,6 anos). Aplicou-se a técnica de toracometria expandida em duas fases: livre movimentação corporal, permitindo avaliação de compensações posturais (toracometria livre) e, bloqueio de movimentos compensatórios, facilitando análise de movimentos do gradil costal (toracometria dirigida). Esta técnica prevê filmagem e observação sistemática dos movimentos, gerando dados numéricos e descritivos permanentes. O estudo de confiabilidade da técnica foi realizado nos dois grupos. Resultados: As medidas de toracometria axial e xifóide (livre e dirigida) apresentaram excelente confiabilidade intra e interexaminadores. As medidas coletadas apresentaram diferenças significantes entre os grupos. Nas crianças com DMD, a toracometria livre apresentou valor de expansibilidade torácica maior, mostrando que as compensações facilitam a mobilidades da caixa torácica. A técnica de toracometria livre apresentada permitiu a descrição de compensações posturais, sendo que as observadas com maior frequência foram os movimentos associados de cabeça, ombro e tórax. Conclusões: A técnica de toracometria expandida apresentou excelente confiabilidade e permitiu descrever os movimentos do tórax e dos arcos costais. Sugere-se sua utilização na avaliação respiratória de crianças com DMD / Background: Thoracic cirtometry is a simple and accessible technique to assess chest mobilization during forced breathing, but does not allow to analyze compensatory movements commonly used by people with chronic diseases, such Duchenne muscular dystrophy (DMD), characterized by progressive degeneration of musculoskeletal system. Objectives: To expand the technique of thoracic cirtometry to allow assessment compensatory movements, to analyze the reliability of the tool and to describe thoracic mobility of children with DMD. Methods: Participated 60 boys, 30 with DMD (10.1 ± 0.5 years) and 30 healthy (9.5 ± 0.6 years). The expanded thoracic cirtometry was organized in two phases: body can move freely, allowing the assessment of postural compensations (free thoracic cirtometry) and with postural movements blocked, facilitating the analysis of movements of the rib cage (conducted thoracic cirtometry). This technique provides systematic observation and recording of body movements, creating descriptive and numeric permanent data. We investigated repeatability and reproducibility. Results: Measures of axial and the xiphoid thoracic cirtometry (free and conducted) showed excellent reliability. All measures showed significant differences between groups. In the DMD boys, free thoracic cirtometry presented a greater value, which probably occurs due to postural compensations. The most commons were movements of head, shoulder and chest. Conclusions: The expanded thoracic cirtometry technique showed excellent reliability and achieved the objectives of determining values related to ribs mobility during deep breath, and to describe compensatory movements. We suggested its use in respiratory evaluation of children with DMD
9

Avaliação da função de membros superiores: desafios na reabilitação física de pacientes pós-AVC / Upper limb functional outcomes: challenges in stroke patients rehabilitation

Terranova, Thaís Tavares 22 July 2016 (has links)
INTRODUÇÃO: O acidente vascular cerebral (AVC) ocupa as primeiras posições entre as principais causas de incapacidade no mundo, sendo que 45% dos sobreviventes permanecem com perda persistente da função motora de membro superior. Diversos estudos relacionados à reabilitação de pacientes pós-AVC têm como objetivo avaliar intervenções para melhora da função motora de membros superiores. Assim, é fundamental que os resultados sejam avaliados de maneira confiável a fim de se garantir dados objetivos que facilitem a comparação entre as diferentes intervenções. No presente trabalho, discutimos as dificuldades inerentes ao contexto de seleção e administração de diferentes instrumentos de avaliação, e sugerimos uma nova metodologia com o objetivo de oferecer maior confiabilidade e sensibilidade ao processo de avaliação da funcionalidade de membros superiores em pacientes pós-AVC. MÉTODOS: Dividimos o conteúdo deste trabalho em duas etapas: I) revisão da bibliografia, na qual foram identificados diferentes instrumentos de avaliação funcional e discutidas suas propriedades psicométricas; II) análise estatística exploratória para detectar possível relação de dependência entre as variáveis obtidas pelo instrumento Wolf Motor Function Test (WMFT) e as variáveis obtidas pelo dispositivo robótico para membro superior coletadas em uma amostra de 41 pacientes em programa de reabilitação. RESULTADOS: Selecionamos 62 publicações que avaliaram as propriedades psicométricas dos instrumentos de avaliação da função de membros superiores pós-AVC. Pela análise dos artigos, identificamos 22 instrumentos e classificamos pelos níveis de funções e estruturas do corpo, e atividade de acordo com a Classificação Internacional da Funcionalidade (CIF). Comparamos os parâmetros das propriedades psicométricas dos 22 instrumentos e selecionamos o WMFT como um instrumento de referência, factível e bem conceituado, para testar a relação de dependência com as variáveis do dispositivo robótico. A partir da análise estatística exploratória, verificamos relação de dependência entre três das variáveis robóticas e a pontuação do WMFT tempo, demonstrada pela significância no teste LIS (p < 0.05), porém a correlação não foi demonstrada pela representação gráfica. CONCLUSÕES: Embora o WMFT seja bem avaliado quanto às propriedades psicométricas, ele apresenta aspectos negativos que impactam na qualidade dos dados coletados, como, por exemplo, subjetividade durante a observação, tempo de aplicação, treinamento dos avaliadores, além de não fornecer informações sobre a coordenação. Por outro lado, dispositivos robóticos produzem variáveis cinéticas e cinemáticas, as quais fornecem variáveis contínuas, objetivas e precisas sobre diferentes aspectos da função de membros superiores como velocidade, coordenação e força. Portanto, tais equipamentos são alternativas eficazes com relação à aplicação de instrumentos de avaliação do desempenho atual como o WMFT. Futuramente, sugerimos estudos que incluam uma amostra mais robusta e diversificada quanto ao grau de incapacidade, para que análise possa ser ampliada para uma modelagem estatística das variáveis / INTRODUCTION: Stroke occupies the first position among the leading causes of disability worldwide, with 45% of survivors remain with persistent loss of motor function of the upper limb. Several studies related to stroke rehabilitation evaluates interventions to improve motor function of upper limbs. Thus, it is fundamental that results are evaluated reliably in order to ensure objective data to facilitate comparison between different interventions. In this paper, we discuss the difficulties inherent in the context of selection and management of different evaluation tools and suggest a new methodology in order to provide greater reliability and sensitivity in the evaluation process of the functionality of the upper limbs in poststroke patients. METHODS: We divided the contents of this work in two steps: I) review of the literature in which identified different functional assessment tools and discussed its psychometric properties; II) exploratory statistical analysis to detect possible relationship of dependency between variables obtained by the instrument Wolf Motor Function Test (WMFT) and the variables obtained by the robotic device for upper limb collected in a sample of 41 patients in rehabilitation program. RESULTS: We selected 62 publications evaluating the psychometric properties of upper limb assessment tools. For the analysis of the articles, we identified 22 instruments and classified by levels of functions and structures of the body and activity according to the International Classification of Functioning (ICF). We compared the parameters of the psychometric properties of the 22 instruments and selected the WMFT as a reference tool, feasible and well-regarded, to test the dependency relationship with the variables of the robotic device. From the exploratory statistical analysis verified dependence between three of the robotic variables and the score WMFT time, demonstrated the significance in test LIS (p < 0.05), but the correlation was not shown by the graphical representation. CONCLUSIONS: Although WMFT has excellent psychometric properties, it has negative aspects that impact in quality of data collected, for example, subjectivity during observation, application time, training of evaluators, besides it does not provide information on the coordination. On the other hand, robotic devices produce kinetic and kinematic variables which provide continuous, accurate and objective variables on different aspects of the upper limb function such as speed, coordination and strength. Therefore, such devices are effective alternatives regarding to assessment tools of current performance as WMFT. In the future, we suggest studies that include a more robust and diverse sample with respect to the degree of disability, so that analysis can be extended to a statistical modeling of the variables
10

Avaliação da função de membros superiores: desafios na reabilitação física de pacientes pós-AVC / Upper limb functional outcomes: challenges in stroke patients rehabilitation

Thaís Tavares Terranova 22 July 2016 (has links)
INTRODUÇÃO: O acidente vascular cerebral (AVC) ocupa as primeiras posições entre as principais causas de incapacidade no mundo, sendo que 45% dos sobreviventes permanecem com perda persistente da função motora de membro superior. Diversos estudos relacionados à reabilitação de pacientes pós-AVC têm como objetivo avaliar intervenções para melhora da função motora de membros superiores. Assim, é fundamental que os resultados sejam avaliados de maneira confiável a fim de se garantir dados objetivos que facilitem a comparação entre as diferentes intervenções. No presente trabalho, discutimos as dificuldades inerentes ao contexto de seleção e administração de diferentes instrumentos de avaliação, e sugerimos uma nova metodologia com o objetivo de oferecer maior confiabilidade e sensibilidade ao processo de avaliação da funcionalidade de membros superiores em pacientes pós-AVC. MÉTODOS: Dividimos o conteúdo deste trabalho em duas etapas: I) revisão da bibliografia, na qual foram identificados diferentes instrumentos de avaliação funcional e discutidas suas propriedades psicométricas; II) análise estatística exploratória para detectar possível relação de dependência entre as variáveis obtidas pelo instrumento Wolf Motor Function Test (WMFT) e as variáveis obtidas pelo dispositivo robótico para membro superior coletadas em uma amostra de 41 pacientes em programa de reabilitação. RESULTADOS: Selecionamos 62 publicações que avaliaram as propriedades psicométricas dos instrumentos de avaliação da função de membros superiores pós-AVC. Pela análise dos artigos, identificamos 22 instrumentos e classificamos pelos níveis de funções e estruturas do corpo, e atividade de acordo com a Classificação Internacional da Funcionalidade (CIF). Comparamos os parâmetros das propriedades psicométricas dos 22 instrumentos e selecionamos o WMFT como um instrumento de referência, factível e bem conceituado, para testar a relação de dependência com as variáveis do dispositivo robótico. A partir da análise estatística exploratória, verificamos relação de dependência entre três das variáveis robóticas e a pontuação do WMFT tempo, demonstrada pela significância no teste LIS (p < 0.05), porém a correlação não foi demonstrada pela representação gráfica. CONCLUSÕES: Embora o WMFT seja bem avaliado quanto às propriedades psicométricas, ele apresenta aspectos negativos que impactam na qualidade dos dados coletados, como, por exemplo, subjetividade durante a observação, tempo de aplicação, treinamento dos avaliadores, além de não fornecer informações sobre a coordenação. Por outro lado, dispositivos robóticos produzem variáveis cinéticas e cinemáticas, as quais fornecem variáveis contínuas, objetivas e precisas sobre diferentes aspectos da função de membros superiores como velocidade, coordenação e força. Portanto, tais equipamentos são alternativas eficazes com relação à aplicação de instrumentos de avaliação do desempenho atual como o WMFT. Futuramente, sugerimos estudos que incluam uma amostra mais robusta e diversificada quanto ao grau de incapacidade, para que análise possa ser ampliada para uma modelagem estatística das variáveis / INTRODUCTION: Stroke occupies the first position among the leading causes of disability worldwide, with 45% of survivors remain with persistent loss of motor function of the upper limb. Several studies related to stroke rehabilitation evaluates interventions to improve motor function of upper limbs. Thus, it is fundamental that results are evaluated reliably in order to ensure objective data to facilitate comparison between different interventions. In this paper, we discuss the difficulties inherent in the context of selection and management of different evaluation tools and suggest a new methodology in order to provide greater reliability and sensitivity in the evaluation process of the functionality of the upper limbs in poststroke patients. METHODS: We divided the contents of this work in two steps: I) review of the literature in which identified different functional assessment tools and discussed its psychometric properties; II) exploratory statistical analysis to detect possible relationship of dependency between variables obtained by the instrument Wolf Motor Function Test (WMFT) and the variables obtained by the robotic device for upper limb collected in a sample of 41 patients in rehabilitation program. RESULTS: We selected 62 publications evaluating the psychometric properties of upper limb assessment tools. For the analysis of the articles, we identified 22 instruments and classified by levels of functions and structures of the body and activity according to the International Classification of Functioning (ICF). We compared the parameters of the psychometric properties of the 22 instruments and selected the WMFT as a reference tool, feasible and well-regarded, to test the dependency relationship with the variables of the robotic device. From the exploratory statistical analysis verified dependence between three of the robotic variables and the score WMFT time, demonstrated the significance in test LIS (p < 0.05), but the correlation was not shown by the graphical representation. CONCLUSIONS: Although WMFT has excellent psychometric properties, it has negative aspects that impact in quality of data collected, for example, subjectivity during observation, application time, training of evaluators, besides it does not provide information on the coordination. On the other hand, robotic devices produce kinetic and kinematic variables which provide continuous, accurate and objective variables on different aspects of the upper limb function such as speed, coordination and strength. Therefore, such devices are effective alternatives regarding to assessment tools of current performance as WMFT. In the future, we suggest studies that include a more robust and diverse sample with respect to the degree of disability, so that analysis can be extended to a statistical modeling of the variables

Page generated in 0.5069 seconds