• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 297
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 311
  • 158
  • 66
  • 41
  • 33
  • 28
  • 28
  • 25
  • 23
  • 23
  • 23
  • 21
  • 20
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo da melhoria do desempenho de sistemas de resfriamento evaporativo por micro aspersão de água / Study of improvement the evaporative cooling system performance by water misting systems

Cássio Luiz Ianni Zapaterra 29 September 2016 (has links)
Disponibilidade dos recursos energéticos junto com o despertar da consciência ambiental criaram um interesse por uma condição climática sensível compatível com os recursos disponíveis. Dentro desse cenário o trabalho se volta à necessidade de se criarem e manterem ambientes industriais termicamente adequados aos processos de produção para minimizar as interferências que as condições ambientais exercem sobre os custos dos processos de produtivos e sobre o consumo energético. Os sistemas de resfriamento evaporativo, por sua vez, têm sido a ferramenta de maior potencial de aplicação na criação de ambientes termicamente adequados aos processos. Este modelo revisto de conforto térmico nos coloca um passo à frente para o aumento eficiência energética na construção de projeto de climatização vinculados a temperaturas interiores que atendam conjuntamente tanto aos ocupantes como às atividades que desenvolvem no interior da área climatizada. Apesar de esse sistema apresentar vantagens operacionais, quando comparado a outros sistemas convencionais, existem certas limitações no seu desempenho. Uma das maiores dificuldades das instalações destes sistemas reside na existência de incertezas em qualquer resultado. Possibilitar um controle dos parâmetros, minimizando os erros de aplicação, evitando criar no ambiente um desconforto de tal grau que inviabilize sua aplicação, é o fundamento deste trabalho. A busca passa a ser pela garantia da aceitabilidade dos resultados do sistema projetado e seus limites de aplicabilidade. O estudo das variáveis que interferem no processo do resfriamento por micro aspersão permitiu desenvolver um processo que alterara esses parâmetros durante o funcionamento do sistema, interferindo, conforme a necessidade no seu desempenho, garantindo a completa evaporação da água micro aspergida. / Energy resources along with an environmental conscience awakening has created an interest in sensitive climate together with a more understanding regarding the use of available resources. Inside this scenario our work focus on the needs of creating and maintaining industrial environments thermally suited to these production processes that seeking to minimize interference that environmental conditions have on the costs of production processes and energy consumption. Evaporative cooling systems, in turn, has been a interesting tool to be used in the creation of thermally suitable environments to these processes. This new revised thermal comfort model puts us a step forward to increase energy efficiency in elaborating air treatment projects linked to indoor temperatures that meet both the occupants and the activities that develop inside the controlled area. Although this system has operational advantages when compared to other conventional systems, there are some limitations in their performance. A major difficulty of the installation envolving these systems is about the existence of uncertainty in any results. To allow the control of these parameters in order to minimize the errors in this kind of application and to avoid creating environmental discomfort to such a degree that prevent the implementation, it is the foundation of this work. The search is to ensure the acceptability of the results of the system designed and their limits of applicability. The study of the variables that affect the cooling process by misting allowed us to develop a process that altered these parameters during operation of the system, interfering, as required in its performance, ensuring complete evaporation of water applied by misting in the area.
102

Sistema híbrido de resfriamento evaporativo e compressão a vapor para condicionamento do ar em veículos

Eric Ferreira dos Santos 30 September 2011 (has links)
Reunir o condicionamento de ar indireto pela compressão a vapor, usando o fluido refrigerante R134a, ao princípio de resfriamento evaporativo direto, foi o tema foco do trabalho. O resfriamento a compressão de vapor tem como resultado, a entrega do ar condicionado sob condições de conforto que podem ser modificados de modo significativo, se for adicionado aos resultados, o condicionamento por resfriamento evaporativo. A observação dos experimentos se baseou nos processos psicrométricos envolvidos, aliando a saturação adiabática do ar no resfriamento evaporativo conjugado ao efeito frigorífico da diferença de entalpias na entrada e saída do evaporador no ciclo convencional de resfriamento. Foi possível avaliar a redução do coeficiente de desempenho e a capacidade de refrigeração aumentando em função do crescimento da rotação do compressor. No ensaio conjugado, resfriamento evaporativo e compressão a vapor instalados em série, observou-se a redução da efetividade do resfriador evaporativo, quando ocorre o aumento da vazão de ar, além do incremento da capacidade de refrigeração em função da associação dos dois sistemas, sem que houvesse aumento significativo da potência consumida. / Assemble the air conditioning by indirect vapor-compression, using refrigerant R134a, the principle of evaporative cooling direct cooling, was the subject focus of the work. The vapor compression cooling results in the delivery of air conditioning under conditions of comfort that can be changed significantly if we add the results, the conditioning by evaporative cooling. The observation of the experiments are bases on psychometric processes involved, combining the adiabatic saturation of air in the evaporative cooling effect of the combined refrigerator of the difference in enthalpy at the inlet and outlet of the evaporator in the conventional cooling cycle. It was possible to evaluate the reduction of the coefficient of performance and cooling capacity increase due to the increase of compressor speed. During the serial aligned pads evaporative cooling and vapor compression test, there was a decrease of the effectiveness evaporative cooler, when the air flow was added, in addition, it was increased the cooling capacity according to the association of the two systems, with no significant increase the power supplied.
103

Estudo da viabilidade do tratamento eletromagnético para água de resfriamento em indústrias químicas. / Study of the feasibility of electromagnetic treatment for cooling water in chemical industries.

Rita Joseane Oliveira Câmara Schaly 18 September 2015 (has links)
O segmento industrial é um grande usuário de água e, na maior parte das situações, está localizado junto a aglomerações urbanas, caracterizando situação de dificuldade na obtenção deste recurso para as suas operações. As fontes de água estão cada vez mais saturadas e os processos de tratamento mais sofisticados. O objetivo deste estudo foi avaliar a viabilidade técnico-econômica da implantação do tratamento eletromagnético para água de resfriamento em indústrias químicas, substituindo ou complementando o tratamento químico convencional. O texto descreve inicialmente os fundamentos do tratamento de água baseado na aplicação de campo eletromagnético e, em seguida, os efeitos do uso dessa tecnologia sobre custos anuais de resfriamento em um caso típico da indústria química. Neste estudo foi dada ênfase ao efeito sobre os custos anuais da menor adição de produtos químicos, redução na vazão de purga e de reposição de água, além da redução na frequência de limpeza dos equipamentos e redução da carga poluente nos efluentes líquidos. O estudo foi aplicado a uma torre de resfriamento industrial, para a qual foi elaborado um modelo matemático considerando as taxas de consumo e especificações de água de resfriamento, além de parâmetros do processo de tratamento de água convencional e eletromagnético. São apresentados resultados de um estudo de sensibilidade para diferentes cenários, em que são identificados os fatores com maior efeito sobre os custos. Além disso, na aplicação ao sistema proposto, são estimadas condições ótimas de operação, considerando os ciclos de concentração para os quais pode haver maior redução de custos. Utilizando-se o tratamento eletromagnético para a água de resfriamento, há uma economia significativa, pois o número de paradas para a manutenção dos equipamentos pode ser reduzido. Dessa forma, o produto final do trabalho constitui-se em uma estrutura de cálculo voltada à estimação de custo do tratamento físico de água de resfriamento, o qual pode ser aplicado a diferentes cenários e condições de operação industrial. / The industrial sector is a major water user and in most situations is located next to urban areas, in a situation of increasing difficulty in collecting and treating water resources for its operations. The water sources are becoming more saturated and thus demanding more sophisticated treatment processes. The aim of this study was to evaluate the technical and economic feasibility of the implementation of electromagnetic treatment of cooling water in chemical industries, thus replacing or complementing the conventional chemical treatment. The text initially describes the principles of the physical process for water treatment based on the application of an electromagnetic field, and then focuses on the effects of the use of this technology on the annual costs of cooling in a typical case of the chemical industry. The study is focused on the effects of the electromagnetic treatment on the annual cost of cooling in view of the reduced consumption of chemicals, as well as reduction in purge flow and water replacement, reduced frequency of equipment cleaning, and reduction of pollution load caused by wastewater. The study results were applied to an industrial cooling tower for which a mathematical model was developed by considering consumption rates and cooling water specifications, as well as parameters of the electromagnetic and conventional water treatment processes. A sensitivity study was carried out for different scenarios, in which the most important factors affecting the annual cost are identified, and optimal process conditions are estimated for maximum concentration cycles. The study shows that the use of electromagnetic treatment for cooling water results in significant savings due to the reduced number of maintenance periods. The final product of this study is a calculation structure for cost estimation related to the physical treatment of cooling water, which can be applied to different scenarios and industrial operation conditions.
104

Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água. / Presentation and comparison of a model based in high mass transfer and supersaturation in a cooling water tower.

Fernandes, Mariana 20 December 2011 (has links)
Torres de resfriamento são equipamentos muito utilizados na indústria e que muitas vezes operam sob condições adversas, particularmente, temperatura de água acima dos 50°C na entrada da torre. Nesta condição, tem-se alta taxa de evaporação e eventualmente condição de alto transporte de massa, normalmente não considerado no equacionamento de torres de resfriamento. Apresenta-se assim uma análise comparativa de diferentes métodos de cálculo de torres de resfriamento: Merkel, Poppe e o modelo proposto. No modelo proposto neste estudo, consideram-se os balanços diferenciais de massa e energia e os mecanismos de transporte simultâneo de calor e massa, na condição de alto transporte de massa e de supersaturação do ar, caso o vapor de água condense na forma de névoa. Para os casos em que há saturação do ar, os balanços diferenciais de massa e energia passam a contemplar este fenômeno a partir do momento em que ocorre a saturação. O modelo matemático desenvolvido consiste de equações diferenciais ordinárias e equações auxiliares, e foi implementado em uma interface Matlab. Os principais parâmetros investigados foram: as vazões de água e ar, a temperatura de bulbo úmido do ar, a temperatura da água na entrada da coluna e a altura da torre. A partir das simulações matemáticas, foram obtidos resultados de temperaturas do ar, da água e da umidade do ar ao longo da coluna, para os diferentes métodos. / Cooling towers are equipment widely used in industrial plants, where these operate under severe conditions such as cooling water inlet temperatures above 50oC. Under this condition, there are high evaporation of water and high mass transfer, generally not considered in performance analysis of a cooling tower. This work presents and analyzes the differences between the proposed model and the Merkel and Poppe approaches. The proposed model in this work is based on differential equations for energy and mass balances and on the mechanisms of combined heat and mass transfers, at high mass transfer condition and considering the supersaturated air from the height of the tower that the excess of water vapor condenses as a mist. At the point that the air became supersaturated, the differential equations for energy and mass balances start to consider the supersaturation phenomena. The mathematical model developed in this work is composed by ordinary differential equations and auxiliary equations which were solved at Matlab. The parameters investigated were water and air mass flow rates, air wet bulb temperature, water inlet temperature and tower height. The results of air and water temperatures, humidity air across the tower height are presented for each method analyzed.
105

Efeito de cultura probiótica em fermentado a base de soja: resistência ao armazenamento refrigerado, ao estresse gastrointestinal in vitro e atividade antimicrobiana / Effect of probiotic culture in fermented soymilk: resistance to cold storage, stress gastrointestinal in vitro and antimicrobial activity.

Piazentin, Anna Carolina Meireles 07 December 2016 (has links)
Alimentos funcionais são alimentos que contêm uma ou mais substâncias capazes de atuar no metabolismo ou na fisiologia do ser humano, promovendo benefícios à saúde. A soja é uma excelente matéria-prima para o desenvolvimento de alimentos funcionais, pois proporciona benefícios ao hospedeiro que apresenta intolerância ou alergia associada ao consumo de produtos lácteos. As bactérias láticas probióticas vêm sendo aplicadas na fermentação de alimentos devido aos benefícios que as mesmas propiciam a saúde, como na manutenção do equilibrio da microbiota intestinal, em distúrbios do metabolismo gastrointestinal e como adjuvante na absorção de determinados nutrientes. Nesse contexto, o presente trabalho tem por objetivo desenvolver um fermentado a base de soja utilizando bactérias probióticas. A fermentação da bebida à base soja foi realizada pelos micro-organismos Streptococcus thermophilus (St), Lactobacillus delbrueckii subsp. bulgaricus (Lb) e Lactobacillus paracasei (Lp) Lpc-37 realizada à 37ºC e também em diferentes condições de resfriamento aplicadas nas amostras ao fim da fermentação e durante os 28 dias de armazenamento refrigerado (4ºC). Os resultados demonstraram que em média o tempo de fermentação foi menor na presença de St, Lb e Lp quando comparada a fermentação realizada apenas por Lp. A exposição das amostras a uma temperatura intermediária de resfriamento (25ºC) durante 8 horas aumentou cerca de 2,1% a viabilidade das co-culturas ternárias, apresentando pós acidificação em média de 0,2 unidades de pH a partir do pH final da fermentação (4,5) até d1. O resfriamento intermediário promoveu uma modificação no perfil de ácidos graxos, demonstrando aumento de 14,5% do ácido linoleico após 28 dias de armazenamento a 4ºC assim, como também, promoveu aumento de 14,6% na produção de ácido lático. Outro resultado relevante e bastante expressivo foi o consumo de sacarose (94,9%). Desta forma, o resfriamento intermediário demonstrou ser um procedimento capaz de aumentar a viabilidade das bactérias em modelo in vitro de estresse gastroinstestinal. De acordo com esses resultados, é possível concluir que o uso do resfriamento intermediário promove maiores benefícios em relação ao perfil microbiológico e de ácidos graxos. / Functional foods are foods that contain one or more substances capable of acting on the metabolism or physiology of the human being, promoting health benefits. Soy is an excellent raw material for the development of functional foods, providing benefits to the intolerant and allergic people to the dairy products consumption. The use of probiotic lactic acid bacteria in food fermentation has become quite common due to the beneficial effects provided by these bacteria to the individuals\' health, maintaining the balance of intestinal microflora, in the gastrointestinal metabolic disorders and as an adjunct in the absorption of certain nutrients. In this context, this study aimed to develop a fermented soy base using probiotic bacteria. Fermentation of soy beverage was made by the microorganisms Streptococcus thermophilus (St), Lactobacillus delbrueckii subsp. bulgaricus (LB) and Lactobacillus paracasei (Lp) Lpc-37 at 37°C and evaluated at the end of the fermentation process and during 28 days of storage at 4°C. The results showed that the fermentation time was less on average in the presence of St, Lb and Lp when compared to the fermentation performed only by Lp. The exposure of samples to a cooling intermediate temperature (25°C) for 8 hours increased about 2.1% the viability of ternary cocultures, with post acidification on average of 0.2 pH units from the final pH of the fermentation (4.5) to d1. The intermediate cooling promoted a change in fatty acid profile, showing a 14.5% increase of linoleic acid after 28 days of storage at 4°C as well as also promoted an increase of 14.6% of lactic acid. Another important and very significant result was the sucrose consumption (94.9%). In this way, the intermediate cooling procedure demonstrated to be able of increase bacteria viability in the in vitro model of gastroinstestinal stress. According to these results, it is possible to conclude that the use of the intermediate cooling promotes greater benefits in relation to the microbiological profile and fatty acids.
106

Evolução estrutural e térmica de um batólito sin-cinemático no orógenos Neoproterozóico Araçuaí (leste do Brasil) / Structural and thermal evolution of a synkinematic batholith from the Neoproterozoic Araçuaí hot orogen (eastern Brazil)

Mondou, Mathieu 20 October 2010 (has links)
A faixa Araçuaí, de idade neoproterozóica, caracteriza-se por apresentar em seu domínio alóctone, uma grande quantidade de intrusões magmáticas, uma crosta parcialmente fundida e rochas de facies granulítica, características de uma geoterma elevada, configurando trata-se de um orógeno quente. A suíte tonalítica Galiléia, alojada em metassedimentos, deformada no estado magmático, representa um grande batólito que influenciou de maneira significativa o comportamento mecânico desta crosta mediana. A Anisotropia de Suscetibilidade Magnética (ASM) medida nesse batólito e usada para um estudo de petrotrama, combinado com uma investigação detalhada sobre a mineralogia magnética, permitiu caracterizar o comportamento paramagnético da Suíte Galiléia e, adicionalmente, trazer informações sobre uma deformacão complexa em 3D. As estruturas observadas se desenvolveram em um magma viscoso resultado de uma combinação da tectônica tangencial induzidas por compressão e forças gravitacionais devido ao peso da crosta sobrejacente. A cinemática do batólito é compatível com aquela descrita para as rochas dúcteis da faixa. Datações U/PB em zircões e monazitas e 40Ar/39Ar em anfibólios, moscovitas e biotitas permitiram definir a evolução termal do batólito Galiléia e de seus metassedimentos hospedeiros e trazer informações sobre o período deformacional. O batólito Galiléia colocouse durante um importante evento magmático, termal e tectônico a ~ 580 Ma. A temperatura permaneceu alta durante os primeiros ~ 50Ma da evolução termal, promovendo uma deformação quase constante do batólito no estado magmático durante várias dezenas de milhões de anos. Tais condições de alta temperatura e cinemática deformacional, estável durante períodos prolongados de tempo, são característicos de orógenos quentes. A taxa de resfriamento vagarosa de ~ 10°C/Ma sugere que após ~500Ma a taxa de exumação foi muito lenta, provavelmente ocasionada apenas pela erosão. / The allochtonous domain of the Neoproterozoic Araçuaí belt involves large amounts of magma, widespread partial melting, granulitic facies and high geotherm, characterising this belt as a hot orogen. The Galiléia tonalitic suite, emplaced within host metasediments and deformed at magmatic state, represents a huge batholith that strongly influenced the mechanical behaviour of this middle crust. The anisotropy of magnetic susceptibility (AMS) measured through this batholith and used as a petrofabric proxy, combined to a detailed magnetic mineralogy investigation, permitted to characterize the paramagnetic behaviour of the Galiléia suite and therefore to highlight a complex 3D strain deformation. The observed structures developed within the viscous magma resulted from a combination of tangential tectonics induced by the compression, and gravitational forces arising from the load of the overlying crust. The kinematics of the batholith is compatible with that already described for ductile rocks of hot orogens. U/Pb dating on zircons and monazites together with 40Ar/39Ar dating on amphiboles, muscovites and biotites permitted to define the thermal evolution of the Galiléia batholith and its host metasediments and constrain the timing of the deformation. The Galiléia batholith emplaced during an important magmatic, tectonic and thermal event at ~580 Ma. Temperature remained high during the first ~50 Ma of the thermal evolution, promoting a seemingly constant deformation of the batholith at magmatic state during several tens of millions years. Such high temperature conditions and stable deformation kinematics during protracted periods of time are supposed to be characteristic of hot orogen. The slow cooling rate of ~10°C/Ma evidenced after ~500 Ma probably indicate a very slow exhumation probably only conducted by erosion.
107

Photoassociation and vibrational cooling of Rb2 molecules with a high-power laser / Fotoassociação e resfriamento vibracional de moléculas de Rb2 com um laser de alta potência

Silva, Paulo Cesar Ventura da 14 February 2017 (has links)
We have developed a technique to produce, manipulate and trap Rb2 molecules with a single optical beam. This beam is generated by a high-power fiber amplifier (50 W of total output power) in the 1060 to 1070 nm range, which is seeded by two light sources: a sharp-band laser and a broadband superluminescent diode. The laser source is tuned to produce Rb2 molecules from an ultracold 85Rb sample via photoassociation. The broadband spectrum vibrationally cool the molecules by optical pumping. This source is spectrally shaped in order to populate the molecules at the fundamental vibrational state ν = 0. The molecular sample is probed by two-photon ionization, promoted by a pulsed dye laser in the 475 to 480 nm range. By scanning the photoassociation laser frequency, we have obtained a photoassociation spectrum of the ν\' = 138 state of the 0+u potential, confirming previous observations. We have also obtained two vibrational spectra of the molecules by varying the ionization laser frequency, in the presence and absence of the broadband source. The comparison between the two spectra, along with ab-initio data, provides evidences that the molecules are optically pumped to the fundamental vibrational state. / Desenvolvemos uma técnica para produzir, manipular e aprisional moléculas de Rb2 com um único feixe óptico. Esse feixe é gerado por um amplificador de alta potência (50 W de potência total de saída) na faixa de 1060 a 1070 nm, que é alimentado por duas fontes de luz: um laser banda estreita e um diodo superluminescente banda larga. O laser é sintonizado para produzir moléculas de Rb2 a partir de uma amostra ultrafria de 85Rb via fotoassociação. O espectro banda larga resfria vibracionalmente as moléculas, por bombeamento óptico. Essa fonte de luz tem seu espectro formatado de modo a deixar as moléculas em seu estado vibracional fundamental ν = 0. A amostra molecular é testada por ionização de dois fótons, promovida por um laser de diodo pulsado na faixa de 475 a 480 nm. Variando a frequência do laser de fotoassociação, obtivemos um espectro de fotoassociação do estado ν\' = 138 do potencial 0+u, confirmando observações anteriores. Obtivemos também dois espectros vibracionais das moléculas variando a frequência do laser de ionização, com e sem a fonte banda larga. Uma comparação entre os dois espectros, junto de dados ab-initio, fornece evidências de que as moléculas são opticamente bombeadas para o estado vibracional fundamental.
108

Análise da influência da concentração e temperatura nas características de resfriamento das soluções do sal AWS-20 usados na têmpera / not available

Messias, Francisco Egidio 12 August 1998 (has links)
A determinação das curvas de resfriamento como alternativa para análise do meio de resfriamento usado nos tratamentos térmicos de têmpera, mostra-se como um dos métodos mais poderosos e eficientes para avaliar e/ou quantificar a severidade de têmpera do meio refrigerante. Assim as soluções de sal AWS-20 testadas como meio de têmpera, tiveram o seu desempenho avaliado pelos métodos tradicionais como perfil da distribuição de dureza em corpos de prova e análise metalográfica e também através das suas curvas de resfriamento. Os resultados obtidos permitiram a sugestão de uma faixa de trabalho para temperatura e concentração com excelente rendimento e sendo confirmado pelo método de análise das curvas de resfriamento. / The determination of the cooling curves as alternative for analysis of the quenching media used in the heat treatments of hardening, is shown as one of the most powerful and efficient methods to evaluate and/or to quantify the quench severity of the quenchant.. Thus, the solutions of salt AWS-20 tested as quenching media, had its, acting evaluated by the traditional methods as profile of the distribution of hardness in test bodies and analysis metallographic and also through its cooling curves. The obtained results allowed the suggestion of a work strip for temperature and concentration with excellent revenue and being confirmed by the method of analysis of the cooling curves.
109

Classificação dos óleos de têmpera nacionais / Classification of national quench oils

Ruggieri, Juliano Emílio 06 April 1998 (has links)
A têmpera, que consiste no resfriamento rápido do aço, após austenitização, é um dos tratamentos térmicos mais utilizados. O objetivo desse tratamento é a obtenção da estrutura martensítica, que oferece ótimas propriedades de dureza e resistência. A água, as soluções de polímeros e os óleos minerais são os meios refrigerantes mais comuns, sendo os óleos responsáveis pelo resfriamento em 80% dos casos. Verificou-se, no Brasil, o desconhecimento, dos mercados produtor e consumidor, quanto ao universo dos óleos de têmpera comercialmente disponíveis e de suas respectivas características de resfriamento. Assim, atentou-se para a necessidade de apresentar aos mercados já descritos, uma classificação dos óleos de têmpera nacionais,relacionando-os como rápidos, intermediários e lentos, destacando ainda, aspectos importantes nos parâmetros de resfriamento. / Quenching of steels, which consist of very fast cooling from austenitizing temperatures, is the most used heat treatment. The aim of this treatment is the obtation of martensitic microstructure. This microstructure confer excellent hardness and strength properties. The most common quenchants are water, polymer solutions and mineral oils, and the oils themselves are responsible by the 80% of the quenchants used during quenching. In Brazil, it was verified consumer lack of knowledge of the oils available as quenchants and their characteristics. Therefore, in this work as attempt was made to present the quenchants available and their classification as fast, intermediary and slow quenchants.
110

Termorregulação em cavalos submetidos a diferentes métodos de resfriamento pós-exercício / Thermoregulation in horses undergoing three different post exercise cooling methods

Etchichury, Mariano 12 December 2008 (has links)
O presente trabalho teve como objetivo comparar dois métodos alternativos de resfriamento pós-exercício em eqüinos, consistentes no uso de água a temperatura ambiente e de gelo nas extremidades, com o método de hiperresfriamento, usado habitualmente nos cavalos de esporte. A necessidade de métodos de resfriamento mais efetivos se baseia no grande quantidade de cavalos eliminados em provas de resistência no país, relacionada à temperaturas ambiente e umidade relativa elevadas. Para comparações foram usados nove cavalos de lida, três machos castrados e seis fêmeas, mestiços, de 8±2,5 anos e peso médio de 462±33 kg, em dois experimentos, um no mês de maio e outro em julho, de 4 dias de duração cada um, com delineamento em cross-over. Os cavalos foram exercitados com protocolo pré-estabelecido em picadeiro durante 30 minutos, e os tratamentos foram aplicados em Câmara Bioclimática. As variáveis estudadas foram: freqüência cardíaca (FC), freqüência respiratória, temperatura retal (TR), taxa de sudação (SUD), temperatura superficial do pescoço (TSP), temperatura superficial do tórax (TST), temperatura superficial da garupa (TSG), temperatura auricular (TAu) e temperatura da base da cauda (TBC). Foram mensurados valores basais pré-exercício, imediatamente pós-exercício sem tratamento, 5, 10, 15 e 20 minutos após o exercício com tratamento, e 5 e 10 minutos pós-tratamento. Os dados foram analisados por regressão linear, e as médias comparadas tempo a tempo pelo teste T de Student. Houve diferença significativa (p<0,05) entre tratamentos nas variáveis TSP, TST, TSG nos dois experimentos, e na TAu no experimento de maio, mas esta diferença foi somente durante o resfriamento, no final do teste ao minuto 30, 10 minutos após serem interrompidos os tratamentos, não houve diferença em nenhuma variável em nenhum dos dois experimentos. Os dois métodos de resfriamento alternativos aqui propostos não apresentaram diferença alguma com o hiper-resfriamento no minuto 30 do teste. / This study was aimed to compare two alternative cooling methods in horses with hyper cooling method, used usually spot horses. Alternatives method consists in tepid water bath of the entire body, and the use of ice in the limbs. The need of alternatives methods of cooling post exercising horses is based in the huge amount of competitors eliminated from endurance rides in Brazil, related to high humidity and hot environments. Nine Standarbred horses were used, three gelding and six mares, aging 8±2,5 years and weighing 462±33 kg, in two experimental sets, performed in May and in July, during four days each, in a cross over experimental design. Horses were exercised in a planned schedule for 30 minutes, after this were placed in a climatic chamber, were treatments were applied. Heart rate, respiratory rate, rectal temperature, sweating, neck skin temperature, thorax skin temperature, croup skin temperature, auricular temperature and tail skin temperature were measured for comparison. Time used in measurements were pre-exercise, immediately post exercise without cooling, 5, 10, 15 and 20 minutes post exercise with cooling, and 5-10 minutes post cooling. Data was processed using linear regression test, and means at each time were compared using T test. Significant difference (p<0,05) was detected in neck skin temperature, thorax skin temperature and croup skin temperature in both experimental sets, and in auricular temperature in May set, although this difference appeared only during cooling treatments. At the end of the test, in minute 30, no difference among treatments were detected in any measurement at any experimental set. Both alternative cooling methods here proposed made no difference in post exercise body cooling terms, when compared with hyper-cooling method, at minute 30 of the test.

Page generated in 0.0783 seconds