• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • Tagged with
  • 66
  • 66
  • 51
  • 42
  • 27
  • 20
  • 20
  • 17
  • 15
  • 13
  • 12
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Efeito do tratamento térmico em microondas e do tempo de armazenamento em água sobre a citotoxicidade de resinas acrílicas para base e reembasamento de próteses

Jorge, Janaina Habib [UNESP] 15 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-15Bitstream added on 2014-06-13T19:45:08Z : No. of bitstreams: 1 jorge_jh_dr_arafo.pdf: 867417 bytes, checksum: c6b45e8ab940eca12be6f09afd58b08f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / A proposta do presente estudo foi avaliar, por meio do teste quantitativo de incorporação de 3H-timidina, o efeito do tratamento térmico em microondas sobre a citotoxicidade de três resinas termopolimerizáveis indicadas para confecção de bases de próteses, em função do tempo de armazenamento em água, e de três resinas autopolimerizáveis indicadas para reembasamento. A hipótese de que o tratamento térmico em microondas poderia diminuir a citotoxicidade de resinas acrílicas foi avaliada. Os materiais testados foram Lucitone 550 (a mufla foi imersa em água à temperatura de 730C permanecendo por 90 minutos, em seguida, à temperatura foi elevada para 1000C e a mufla mantida por mais 30 minutos), QC 20 (a mufla foi imersa em água em ebulição, o aquecimento foi mantido e a mufla permaneceu no recipiente por um período de 20 minutos contados a partir do momento em que a água atingiu novamente à temperatura de ebulição e Acron MC (a mufla foi levada ao forno de microondas durante 3 minutos à potência de 500 W) e os reembasadores Tokuyama Rebase II, Kooliner e New Truliner. Foram confeccionados, em condições assépticas, corpos-de-prova de cada resina em forma de discos medindo 10 mm de diâmetro e 1 mm de espessura. As amostras das resinas termopolimerizáveis foram armazenadas em água destilada por 0, 24 ou 48 horas a 37ºC. Para avaliar o efeito do tratamento térmico em microondas, os corpos-de-prova de todas as resinas foram divididos em dois grupos: 1) sem tratamento térmico e 2) com tratamento térmico em microondas, com as amostras imersas em água, irradiadas durante 3 minutos à 500 W. Os extratos das resinas foram preparados colocando-se três corpos-de-prova de cada grupo experimental, após terem recebido o tratamento térmico, em tubos de ensaio com 9 ml de meio de cultura Eagle e incubados a 37ºC por 24 horas. Um tubo de ensaio, contendo apenas 9 ml de meio... / The aim of the current study was to evaluate the effect of microwave post-polymerization heat-treatments and water storage time on the cytotoxicity of denture base and reline acrylic resins. The hypothesis that post-polymerization treatment could decrease the cytotoxicity of acrylic base resins was tested in this study. The materials tested were Lucitone 550 (water-bath at a temperature of 73ºC for 90 minutes, followed by 30 minutes of heating at 100ºC), QC 20 (boil water, insert flask, return to boil, boil for 20 minutes) and Acron MC (microwave-polymerized, irradiated for 3 minutes at 500 W) and the hard chair-side reline resin Tokuyama Rebase II, Kooliner and New Truliner. Sample disks of the denture base resins were fabricated under aseptic conditions in mold 10 mm in diameter by 1 mm thick. The samples of the denture base acrylic resins were stored in distilled water for 0, 24 and 48 hours at 37ºC. To assess the biologic effect of the heat-treatment on the denture resins, samples fabricated were further divided into two groups: 1) samples without heat-treatment; and 2) sample were treated in microwave, immersed in water, irradiated for 3 minutes at 500 W. Eluates of the materials were prepared by placing three disks into a sterile glass vial with 9 ml of Eagle's medium supplemented with antibiotics and fetal bovine serum. These were incubated for 24 hours at 37ºC. Medium without disks was also incubated and diluted as above to serve as the control. L929 mouse fibroblasts (1 x 104 cell/ml) were cultivated in Eagle's medium supplemented with antibiotics and fetal bovine serum in 96 well culture plates and incubated for 24 hours at 37ºC in an air atmosphere containing 5% CO2. After 24 hours of incubation, the culture medium was replaced by 50 ml of eluate and 50 ml of fresh medium were added to each well of the 96-well culture plate and incubated for more... (Complete abstract, click electronic address below)
52

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química

Moreno, Amália [UNESP] 13 June 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-13Bitstream added on 2015-05-14T16:58:38Z : No. of bitstreams: 1 000821328.pdf: 1693611 bytes, checksum: 2f11602ee222c6ad0cb896f0664f78e8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Considering that ocular prostheses restore esthetics and patient’s self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / FAPESP: 11/05864-8
53

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental

Almeida, Carolina Souza [UNESP] 09 February 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-09. Added 1 bitstream(s) on 2015-09-17T15:49:21Z : No. of bitstreams: 1 000843397.pdf: 1823033 bytes, checksum: c39021817bdac57624d83d1107f2cb19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh
54

Influência da pigmentação, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial

Haddad, Marcela Filié [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28Bitstream added on 2014-08-13T18:00:07Z : No. of bitstreams: 1 000764939.pdf: 4285251 bytes, checksum: 9da5ef190038848837a8d33e81f903b8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Próteses maxilofaciais retidas por implantes necessitam de uma infraestrutura acrílica, na qual ficam contidos os sistemas de retenção; contudo, a união resina acrílica-silicone facial não é estável. Assim, este estudo teve como objetivo avaliar a influência da pigmentação com nanopartículas, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial. Para tal, foram confeccionadas 960 amostras que consistiam em uma barra de resina acrílica de ativação química aderida ao silicone facial Silastic MDX 4-4210 incolor ou pigmentado com nanopartículas (tinta a óleo e/ou opacificador a base de sulfato de bário). A adesão entre os dois materiais foi feita pela simples deposição do silicone sobre a resina acrílica (N); por retenções mecânicas, representadas por ranhuras (R); aplicação do primer de uso médico (DC 1205 Prime - DC); primer para material reembasador (Sofreliner Primer MS- SF) ou adesivo de uso médico (Silatic Medical Adhesive Type A - A) isolados ou associados. Desta maneira, as amostras foram divididas em 4 grupos (n=240), de acordo com a nanopartícula adicionada ou não, sendo Grupo 1: Incolor; Grupo 2: Tinta a óleo; Grupo 3: Opacificador; e Grupo 4: Tinta a óleo e opacificador. Estes grupos foram divididos em 12 subgrupos (n=20), de acordo com o meio utilizado para unir a resina acrílica ao silicone, sendo: Subgrupo I: N; Subgrupo II: A; Subgrupo III: DC; Subgrupo IV: DC+A; Subgrupo V: SF; Subgrupo VI: SF+A; Subgrupo VII: R; Subgrupo VIII: R+A; Subgrupo IX: R+DC; Subgrupo X: R+DC+A; Subgrupo XI: R+SF; Subgrupo XII: R+SF+A. Metade das amostras de... / Maxillofacial prosthesis retained by implants use an acrylic framework to fit the attachment systems. However, the bond between acrylic resin and facial silicone is instable. Therefore, this study investigated the influence of nanoparticles pigments, adhesive system and accelerated aging on the bond strength between the acrylic resin and facial silicone. A total of 960 specimens made of selfpolymerized acrylic resin bar adhered to Silastic MDX 4-4210 facial silicone either colorless or pigmented with nanoparticles (oil tint and/or barium sulfate opacifier) were fabricated. The union between the two materials was performed in different ways: no treatment on the acrylic bar (N), mechanical retentions represented by scratches (R), application of prime for medical use (DC 1205 Prime - DC), primer for soft liner material (Sofreliner Primer MS - SF), and adhesive for medical use (Silastic Medical Adhesive Type A - A) alone or in combinations. The specimens were divided into 4 groups (n=240) according to the nanoparticle presence: Group 1: colorless; Group 2: oil tint; Group 3: opacifier; and Group 4: oil tint and opacifier. These groups were divided into 12 subgroups (n=20) according to the surface treatment used to bond the facial silicone to the acrylic resin: Subgroup I: N; Subgroup II: A; Subgroup III: DC; Subgroup IV: DC+A; Subgroup V: SF; Subgroup VI: SF+A; Subgroup VII: R; Subgroup VIII: R+A; Subgroup IX: R+DC; Subgroup X: R+DC+A; Subgroup XI: R+SF; Subgroup XII: R+SF+A. Half of the specimens of each subgroup (n=10) were subjected to bond strength test at the baseline period in a universal testing machine at a crosshead speed of 10 mm/min until failure. The other specimens were exposed to the accelerated... / FAPESP: 10/02937-1
55

Avaliação da reação tecidual de uma resina termoplástica em tecido subcutâneo de ratos

Alfenas, Elizabeth Rodrigues [UNESP] 31 July 1995 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-07-31Bitstream added on 2015-01-26T13:30:30Z : No. of bitstreams: 1 000022881.pdf: 1385395 bytes, checksum: efffbbc6c72ead3e8277aa26da7979ee (MD5) / A reação tecidual do subcutâneo de ratos foi avaliada por meio da implantação de corpos de prova de uma resina termoplástica (T AK Hydroplastic-DFL). A resina termoplástica foi testada em suas diferentes cores (rosa, amarela, azul e branca). Utilizamos como grupo controle a resina acrílica termicamente ativada incolor. Os corpos de prova em forma de pastilhas, com aproximadamente 8 mm de diâmetro por 1 mm de espessura, foram inseridos em lojas cirúrgicas preparadas no dorso dos animais, que foram sacrificados após os períodos de observação de 2, 3, 6, e 12 semanas. Os tecidos adjacentes aos implantes foram removidos, receberam tratamento histológico de rotina, coloração pela hematoxilina e eosina e pelo tricrômio de Mallory. Os resultados foram analisados por microscopia óptica, e o tecido subcutâneo adjacente aos implantes de resina termoplástica exibiu reação inflamatória moderada nos períodos iniciais de observação (2 e 3 semanas) com reparação da área e formação de cápsula fibrosa envolvendo todos os corpos de prova no período final de 12 semanas. Os resultados obtidos nos permitiram concluir que: • a resina termoplástica nas cores rosa, amarela, azul e branca, não determinou reação tecidual desfavorável em 12 semanas de implantação; • a resina do Grupo controle e a resina termoplástica azul determinaram uma resposta tecidual menos favorável do que a da resina termoplástica nas cores rosa, amarela e branca / Subcutaneous rat tissue reaction was evaluated using samples of a thermoplastic resin(TAK Hydroplastic-DFL) of different colours: pink, yellow, blue and white. As control, a transparent thermally activated acrylic resin was used. Samples with a diameter of approximately 8 mm and thickness of 1 mm were implanted in surgical wounds on the back of rats, which were then sacrificed at periods of 2, 3, 6, and 12 weeks. The adjacent tissue was removed and prepared histologically using hematoxilin-eosin and Mallory trichrorne techniques. Through optical microscopy, it was observed that the subcutaneous adjacent to the resin implants showed a moderate inflammatory reaction during the weeks 2 and 3. At the end of week 12, tissue recovery and capsular formation surrounding the resin implant were observed. It was concluded that: • the thermoplastic resin in pink, yellow, b1ue and white colours didn't determine unfavourable tissue reaction in the 12 weeks of implantation; • the resin of the control group and the blue thermoplastic resin determined a tissue response that was less favourable than the thermoplastic resin in pink, yellow and white colours
56

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses

Chuqui, Roberta [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T18:38:57Z : No. of bitstreams: 1 chuqui_r_me_arafo.pdf: 5214724 bytes, checksum: 7fcde9af460bda49c5c01007a97620cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)... / This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below)
57

Efeito da irradiação por microondas sobre as propriedades viscoelásticas de resinas para base de prótese e reembasamento

Lombardo, Carlos Eduardo Leão [UNESP] 25 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-25Bitstream added on 2014-06-13T19:38:22Z : No. of bitstreams: 1 lombardo_cel_me_arafo.pdf: 3996119 bytes, checksum: c7eb8e08977bab50ee60b2bacfeaab4e (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da irradiação por microondas e da armazenagem em água sobre as propriedades viscoelásticas de duas resinas para base de prótese (Lucitone 550- L e Vipi Wave- VW) e duas resinas para reembasamento imediato (Kooliner- K e Tokuyama Rebase Fast II- TR II). Oito corpos-de-prova (40 x 10 x 3,3 mm) de cada material foram avaliados por meio de análise térmica dinâmico-mecânica (DMTA) após: acabamento (controle 1), armazenagem em água por 7 dias (controle 2), um (MW1) e 7 ciclos de irradiação por microondas (MW7). Para cada corpo-de-prova, ciclos de DMTA foram realizados dentro de intervalos de temperatura diferentes. Os valores do módulo de armazenamento (E’) e de amortecimento mecânico (tan δ) a 37ºC foram obtidos no primeiro e último ciclos de DMTA. A partir do último ciclo, os valores de E’ na temperatura de transição vítrea (Tg) e o máximo de tan δ também foram obtidos. Os dados foram submetidos à análise de variância a dois critérios e ao teste de Student-Newman-Keuls (α=0,05). Além disso, mensurações de temperatura no interior de corpos-de-prova de cada material, durante a irradiação por microondas (650 W/ 3 min), foram realizadas por meio da utilização de sensor de fibra óptica. Seis corpos-de-prova de cada material foram avaliados. Durante a irradiação por microondas, todos os corpos-de-prova atingiram a temperatura de ebulição da água em aproximadamente 130 s. A partir do primeiro ciclo de DMTA, MW 1 e controle 2 aumentaram significantemente os valores de E’ e reduziram os valores de tan δ de K a 37ºC (P<0,05). No último ciclo de DMTA, o tan δ de K e TR II foi significantemente reduzido após MW1 (P<0,05). MW7 reduziu os valores de tan δ de K (P<0,05). Os valores de E’ de L e VW foram semelhantes entre si e superiores aqueles produzidos por K e TR II (P<0,05). Na Tg, K produziu o menor E’ e seu máximo... / This study evaluated the effect of microwave irradiation and water storage on the viscoelastic properties of two denture base resins (Lucitone 550-L and Vipi Wave-VW) and two reline resins (Kooliner-K and Tokuyama Rebase Fast II-TR II). Eight specimens (40x10x3.3mm) of each material were evaluated by dynamic mechanical thermal analysis (DMTA) after: processing, water storage for 7 days (WS), one (MW1) and 7 cycles of microwave irradiation (MW7). For each specimen, DMTA runs were carried out within different temperature intervals. Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. From the last run, values of E’ at the glass transition temperature (Tg) and maximum tan δ were also recorded. Data were analyzed by 2-way ANOVA followed by Student-Newman-Keuls test (α=0.05). In addition, measurements of the inside temperature of each specimen during microwave irradiation (650W/3min) were conducted using a fiber optic temperature sensor. Six specimens of each material were evaluated. During microwave irradiation, all specimens reached the boiling temperature of water at approximately 130 s. From the first DMTA run, MW1 and WS significantly increased the E’ and decreased the tan δ of K at 37°C (P<0.05). From the last run, the tan δ of K and TR II was significantly decreased after MW1 (P<0.05). MW7 decreased the tan δ of K (P<0.05). The E’ of L and VW was similar and higher than K and TR II (P<0.05). At Tg, K produced the lowest E’ and its maximum tan δ was increased after MW1 (P<0.05). The Tg mean values were arranged as: L>VW>TR II>K (P<0.05). Microwave irradiation and WS did not detrimentally affect the viscoelastic properties of the denture base and reline resins evaluated.
58

Produção de água eletrolisada ácida para uso em odontologia

Campregher, Ulisses Bastos January 2011 (has links)
O objetivo desse trabalho foi desenvolver um aparelho experimental de baixo custo para produção de água eletrolisada ácida (AEA) e verificar sua eficácia na desinfecção de resina acrílica termo polimerizável (RA). Além disso, verificou-se a influência da AEA nas seguintes propriedades da RA. Sorção, Solubilidade, Resistência Flexural, Microdureza Knoop e Rugosidade Superficial. A AEA foi produzida através do processo de eletrólise de uma solução de NaCl a 5% numa célula eletrolítica de dois compartimentos separados por uma membrana semipermeável. Foram utilizados eletrodos de grafite e a diferença de potencial aplicada entre eles foi de 30 V, gerada por um alimentador com capacidade máxima de corrente de 2 A. Após 20 minutos de eletrólise a solução anódica (AEA) apresentou os seguintes parâmetros: pH 3,0 e potencial de óxi-redução de 1150 mV. O tempo de imersão na solução para o ensaios de desinfecção bem como os de propriedades características da RA foi de 10 minutos. A AEA foi eficaz na desinfecção da RA pois os corpos desinfectados não provocaram a turvação dos meios de cultura. A imersão em AEA aumentou estatisticamente (p<0,05) a sorção e a solubilidade da resina acrílica, porém os valores permaneceram dentro dos parâmetros estabelecidos pela ISO 1567. As demais propriedades da resina ficaram inalteradas (p>0,05). / The aim of this research was to develop a low cost experimental apparatus able to produce Electrolyzed Acidic Water (EAW) and verify its efficacy for disinfection of a denture base acrylic resin (AR). It was also verified the influence of EAW on the following properties of AR: Sorption, Solubility, Flexural Strength, Knoop Hardness and Superficial Rugosity. EAW was produced through an electrolysis process of an aqueous NaCl solution (5%) in an electrolytic two chambers cell with a separation membrane between the chambers. Graphite electrodes were used and the potential difference between them was 30 V, provided by a power supply with maximum amperage capacity of 2 A. 20 minutes after the begging of the electrolysis process the anodic solution (EAW) showed the following parameters: pH 3.0 and oxidation-reduction potential (ORP) of 1150 mV. The immersion time in the solution for the disinfection test and also for the evaluation of AR properties was 10 min. EAW was able to disinfect AR as the infected specimens did not cause turbidity of the culture medium. Immersion in EAW increased the sorption and decreased the solubility of the AR in a statistically significant way (p<0.05) but it was within the range required by ISO 1567. All the other AR properties suffered no changes (p<0.05)
59

Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superiores

Shibayama, Ricardo [UNESP] 19 September 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-09-19Bitstream added on 2014-06-13T19:37:38Z : No. of bitstreams: 1 shibayama_r_me_araca.pdf: 3106543 bytes, checksum: c84fd00a6f34341aaf54e2572db11b66 (MD5) / Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four.
60

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas

Basso, Michael Frederico Manzolli [UNESP] 27 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-27Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 basso_mfm_dr_arafo.pdf: 618642 bytes, checksum: a30b4dfd3eaaae29f0c670dfb57dbd55 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... / Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below)

Page generated in 0.0481 seconds