• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 11
  • 11
  • 11
  • 11
  • 9
  • 2
  • 1
  • 1
  • Tagged with
  • 313
  • 313
  • 188
  • 184
  • 86
  • 81
  • 74
  • 74
  • 61
  • 53
  • 50
  • 41
  • 38
  • 36
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação da influência da incorporação de substâncias desinfetantes na resistência à compressão e à tração diametral de dois gessos tipo IV

Batista, André Ulisses Dantas [UNESP] 21 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-21Bitstream added on 2014-06-13T19:05:06Z : No. of bitstreams: 1 batista_aud_dr_arafo.pdf: 615250 bytes, checksum: 0ecd726c988be8090372e448348080fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi analisar a influência da incorporação de três desinfetantes (hipoclorito de sódio a 1%, glutaraldeído alcalino a 2% e digluconato de clorexidina a 2%) em duas diferentes porcentagens de substituição da água da espatulação (50 e 100%) de dois gessos tipo IV, FujiRock EP (M1) e Rock Plus (M2), avaliando-se a resistência à compressão e à tração diametral. Os corpos-de-prova foram obtidos a partir de matrizes metálicas bipartidas com 20 mm de diâmetro e 40 mm de altura (resistência à compressão) e 20 mm de diâmetro e 10 mm de altura (resistência à tração diametral). As matrizes foram fixadas sobre uma placa de vidro, o gesso foi manipulado na proporção água/pó recomendada pelos fabricantes (M1:20ml/100g e M2:19 ml/100g), em um espatulador mecânico por 30 segundos, e vazado sob vibração. Para cada ensaio foram confeccionados sete grupos para cada gesso (n=10). Os grupos foram: CONTROLE (Água destilada), G50 (substituição de 50% da água de espatulação por glutaraldeído), G100 (100% de glutaraldeído), C50 (substituição de 50% da água por clorexidina), C100 (100% de clorexidina), H50 (substituição de 50% da água por hipoclorito) e H100 (100% de hipoclorito). Após a presa os corpos-de-prova foram removidos das matrizes e armazenados à temperatura ambiente. Os ensaio de compressão e tração diametral foram realizados 24 horas após o vazamento, em uma máquina de ensaios MTS-810, com célula de carga de 100 KN à velocidade de 0,5mm/min. Os valores médios de resistência à compressão e à tração diametral (MPa) foram submetidos à análise de variância e teste de Tukey, com nível de significância de 95%, permitindo concluir que: (a) a incorporação das substâncias desinfetantes estudadas afetou a resistência à compressão de ambos os gessos analisados; (b) as diferentes proporções de incorporação das substâncias... / The purpose of this study was to evaluate the compressive and diametral tensile strength of two Type IV dental stones, FujiRock EP (M1) e Rock Plus (M2), mixed with three disinfectant solutions (sodium hypochlorite 1%, chlorhexidine digluconate 2% and glutaraldehyde 2%) in two different proportions of gauging water (50% and 100%). Compressive samples consisted of cylindrical specimens, each having a diameter of 20 mm and length of 40 mm, and diametral tensile specimens consisted of discshaped specimens, having a diameter of 20 mm and length of 10 mm, obtained from split metal molds. The stone was mixed with the solutions previously outlined at the water-powder ratio recommended by the manufacturers (M1:20ml/100g e M2:19 ml/100g), mechanically spatulated under vacuum (Turbomix) for 30 seconds, and gently vibrated in the molds. Seven groups were prepared for each test, with 10 samples each, as follows: CONTROL (distilled water), G50 (substitution of 50% of gauging water by glutaraldehyde), G100 (only glutaraldehyde), C50 (substitution of 50% of gauging water by chlorhexidine digluconate), C100 (only chlorhexidine digluconate), H50 (substitution of 50% of gauging water by sodium hypochlorite) and H100 (only sodium hypochlorite). Specimens were removed from the molds after they set. Compressive strength and diametral tensile strength was determined 24 hours the specimens were cast, in an MTS-810 testing machine, with a cross-head speed of 0,5mm/min. Mean compressive and diametral tensile strength was calculated and expressed in megapascals (MPa). Data from both tests were analyzed by ANOVA and Tukey test, showing that: (a) chemical disinfectants incorporation reduced the compressive strength of type IV dental stones evaluated; (b) the use of two different proportions of gauging water substitution by disinfectants (50% and 100%) has affected the compressive strength of only one die stone (M1); (c) chemical disinfectants incorporation did not reduced.
132

Caracterização mecânica e microestrutural do aço MARAGING 300, soldado a plasma e submetidas a reparos

Silva, Deivid Ferreira da [UNESP] 25 June 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-25Bitstream added on 2014-12-02T11:21:16Z : No. of bitstreams: 1 000798568.pdf: 2713278 bytes, checksum: 54b323731ba9273bbe179d043c8c0cc5 (MD5) / Este trabalho tem como objetivo avaliar e quantificar as possíveis perdas na resistência mecânica da junta soldada de aço MARAGING 300, após a realização de até três reparos no cordão da solda. O Instituto de Aeronáutica e Espaço (IAE) projeta, desenvolve e fabrica foguetes de sondagem e veículos lançadores de satélites (VLS) utilizando propelente sólido e o envelope metálico é o responsável por suportar a pressão de trabalho durante a queima deste propelente. Atualmente o envelope motor é fabricado em aço 300M-ESR e, devido a uma série de vantagem nas propriedades mecânicas encontradas e no processo de confecção, o IAE estuda a substituição do aço 300M-ESR pelo aço MARAGING 300. O método de soldagem utilizado para a realização do trabalho foi o processo de soldagem a plasma (PLASMA ARC WELDING – PAW) em passe único, utilizando-se a técnica keyhole com metal de adição. Estas juntas soldadas são avaliadas por ensaios não destrutivos, adotando critérios de aceitação de acordo com a norma AWS D17.1. Neste trabalho, a confecção dos reparos foi feita de forma manual, utilizando o método TIG (TUNGSTEN INERT GAS). Foram realizadas as avaliações de resistência mecânica, perfil de dureza Vickers (HV) por microindentações, análises químicas, análises metalográficas e fractográficas da junta soldada nas diversas condições de soldagem. Os resultados mostram que após a solda e reparos, antes do tratamento térmico de envelhecimento, a região fundida e a região adjacente à solda apresentam uma dureza abaixo das outras regiões afetadas termicamente, isto se deve a segregação de solutos na região. Com o envelhecimento há uma elevação nos níveis de dureza de cerca de 200HV, porém a zona fundida e a zona próxima à solda permanece com uma dureza um pouco inferior ao restante do material. As anális... (Resumo completo, clicar acesso eletrônico abaixo) / This study aims to evaluate and quantify the possible losses of mechanical resistance in the welded join of MARAGING 300 steel submitted within three after repairs in the cords of the welded. The Institute of Aeronautics and Space (IAE) designs, develops and manufactures sounding rockets and satellite launcher vehicles (VLS) using solid propellant and the motor case is responsible for supporting the pressure during the burning of this propellant. Currently, the motor case is made of 300M-ESR steel. Due to a number of advantages found in the mechanical properties and the manufacturing process, IAE is studying the replacement of 300M-ESR steel by MARAGING 300 steel. The welding method used for achievement of the work was the process of plasma arc welding (paw) in a single pass, using the keyhole technique with filler metal. The welded joints are evaluated by adopting non-destructive testing acceptance criteria according to AWS D17.1. In this work, the repairs were done, manually, using the tungsten inert gas method (TIG). Measures of mechanical strength, Vickers hardness (HV), chemical analysis, metallographic analysis and fractography of the welded joint were made at the various welding conditions. The results show that after welding and repair and before the aging heat treatment the adjacent region to the weld fusion zone have hardness lower than other regions affected thermally. It is due to segregation of solute in the region. After aging treatment there is an increase in levels of hardness of about 200HV, but the fusion zone and near the weld zone with hardness remain slightly lower than the rest of the material. The analyzes of the fractured surface showed that the rupture of the specimens occurred in the region of the heat affected zone near the weld , and has a appearance of mixed fractures with formation predominantly of microvoid (dimples) ... (Complete abstract click electronic access below)
133

Caracterização mecânica e microestrutural do aço MARAGING 300, soldado a plasma e submetidas a reparos /

Silva, Deivid Ferreira da, 1978. January 2014 (has links)
Orientador: Antonio Jorge Abdalla / Coorientador: Marcelo dos Santos Pereira / Banca: Tomaz Manabu Hashimoto / Banca: Olivério Moreira de Macedo Silva / Resumo : Este trabalho tem como objetivo avaliar e quantificar as possíveis perdas na resistência mecânica da junta soldada de aço MARAGING 300, após a realização de até três reparos no cordão da solda. O Instituto de Aeronáutica e Espaço (IAE) projeta, desenvolve e fabrica foguetes de sondagem e veículos lançadores de satélites (VLS) utilizando propelente sólido e o envelope metálico é o responsável por suportar a pressão de trabalho durante a queima deste propelente. Atualmente o envelope motor é fabricado em aço 300M-ESR e, devido a uma série de vantagem nas propriedades mecânicas encontradas e no processo de confecção, o IAE estuda a substituição do aço 300M-ESR pelo aço MARAGING 300. O método de soldagem utilizado para a realização do trabalho foi o processo de soldagem a plasma (PLASMA ARC WELDING - PAW) em passe único, utilizando-se a técnica keyhole com metal de adição. Estas juntas soldadas são avaliadas por ensaios não destrutivos, adotando critérios de aceitação de acordo com a norma AWS D17.1. Neste trabalho, a confecção dos reparos foi feita de forma manual, utilizando o método TIG (TUNGSTEN INERT GAS). Foram realizadas as avaliações de resistência mecânica, perfil de dureza Vickers (HV) por microindentações, análises químicas, análises metalográficas e fractográficas da junta soldada nas diversas condições de soldagem. Os resultados mostram que após a solda e reparos, antes do tratamento térmico de envelhecimento, a região fundida e a região adjacente à solda apresentam uma dureza abaixo das outras regiões afetadas termicamente, isto se deve a segregação de solutos na região. Com o envelhecimento há uma elevação nos níveis de dureza de cerca de 200HV, porém a zona fundida e a zona próxima à solda permanece com uma dureza um pouco inferior ao restante do material. As anális... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aims to evaluate and quantify the possible losses of mechanical resistance in the welded join of MARAGING 300 steel submitted within three after repairs in the cords of the welded. The Institute of Aeronautics and Space (IAE) designs, develops and manufactures sounding rockets and satellite launcher vehicles (VLS) using solid propellant and the motor case is responsible for supporting the pressure during the burning of this propellant. Currently, the motor case is made of 300M-ESR steel. Due to a number of advantages found in the mechanical properties and the manufacturing process, IAE is studying the replacement of 300M-ESR steel by MARAGING 300 steel. The welding method used for achievement of the work was the process of plasma arc welding (paw) in a single pass, using the keyhole technique with filler metal. The welded joints are evaluated by adopting non-destructive testing acceptance criteria according to AWS D17.1. In this work, the repairs were done, manually, using the tungsten inert gas method (TIG). Measures of mechanical strength, Vickers hardness (HV), chemical analysis, metallographic analysis and fractography of the welded joint were made at the various welding conditions. The results show that after welding and repair and before the aging heat treatment the adjacent region to the weld fusion zone have hardness lower than other regions affected thermally. It is due to segregation of solute in the region. After aging treatment there is an increase in levels of hardness of about 200HV, but the fusion zone and near the weld zone with hardness remain slightly lower than the rest of the material. The analyzes of the fractured surface showed that the rupture of the specimens occurred in the region of the heat affected zone near the weld , and has a appearance of mixed fractures with formation predominantly of microvoid (dimples) ... (Complete abstract click electronic access below) / Mestre
134

Influência de agentes antiproteolíticos na resistência de união da interface dentina, adesivo e cimento resinoso /

Kamozaki, Maria Beatriz Beber January 2016 (has links)
Orientador: Clovis Pagani / Coorientadora: Anuradha Prakki / Banca: Eduardo Bresciani / Banca: Ricardo Amore / Banca: Eron Toshio Colauto Yamamoto / Banca: Graziela Ribeiro Batista / Resumo: O objetivo deste trabalho, foi avaliar a influência de agentes antiproteolíticos, imediatamente e após 12 meses, na cimentação adesiva. Foram utilizadas as porções coronárias de 64 molares humanos hígidos. As amostras foram divididas aleatoriamente em 4 grupos, de acordo com o tratamento da dentina: CT (grupo controle); CXL (grupo clorexidina); EGCG (grupo epigalocatequina-3-galato); AT (grupo antocianina). Para a restauração, foram confeccionados cilindros em resina composta Filtek Z350 XT. Após o condicionamento ácido da dentina, as soluções antiproteolíticas foram aplicadas e mantidas sobre a superfície por 60 s, em seguida as restaurações foram cimentadas às amostras com o adesivo Adper Single Bond 2 + cimento resinoso Variolink II. Todos os grupos foram subdivididos de acordo com o tempo de armazenamento em água destilada para o ensaio mecânico: I (Imediato = após 24 h); A (Armazenado = após 12 meses). As amostras foram cortadas em palitos e submetidas ao teste de microtração. Os dados obtidos foram submetidos ao teste de ANOVA a 2 fatores, seguido do teste de Tukey (α=5%). Foram encontradas diferenças para os fatores Tratamento (p=0,03) e Armazenamento (p=0,00). Os valores em MPa de média e desvio padrão para interação entre os fatores Tratamento X Armazenamento, foram: CT.I: 42.56 (±7,60) A; EGCG.I: 39.6 (±8,99) A; CLX.I: 39.37 (±9,44) A; AT.I: 38.69 (±8,65) A; CT.A: 31.85 (±6,96) A; AT.A: 31.29 (±4,89) AB; EGCG.A: 30.94 (±9,91) AB; CLX.A: 18.68 (±4,53) B. Foram confe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : The aim of this study was to evaluate immediately and longitunally the antiproteolytic agent influence to adhesive cementation. Were used 64 coronary portion of sound human molars. The samples were divided into 4 groups according to the dentin treatment: CG (Control group); CLX (chlorhexidine group); EGCG (epigallocatechin-3- gallate group); AT (anthocyanin group). Cylindrical composite blocks were prepared using a resin composite Filtek Supreme for the restorations. The solutions were applied on the acid-etched dentin and were kept for 60 s. The resin composite blocks were cemented with the adhesive system Adper Single Bond 2 + resin cement Variolink II. All groups were subdivided according to the storage time in distilled water for mechanical testing: I (Immediate = after 24 h); S (Stored = after 12 months). Samples were cut into beams and tested in a universal testing machine at a crosshead speed of 0.5 mm/min until failure. The data were submitted to two-way ANOVA, followed by the Tukey test (α = 5%). Significant differences were found for the Treatment factor (p = 0.03) and Storage factor (p = 0.00). The mean values and standard deviation for interaction between the factors Treatment X Storage, were CG.I: 42.56 (± 7.60) A; EGCG.I: 39.6 (± 8.99) A; CLX.I: 39.37 (± 9.44) A; AT.I: 38.69 (± 8.65) A; CG.S: 31.85 (± 6.96) A; AT.S: 31.29 (± 4.89) AB; EGCG.S: 30.94 (± 9.91) AB; CLX.S: 18.68 (± 4.53) B. Two additional samples from each group were confectioned to descriptive analyses of microhardness knoop of dentin subjacent to the bonding interface and a qualitative interface evaluation with SEM (scanning electron microscope). It can be conclude that EGCG and AT solutions were able to maintain the bond strength stability after 12 months of storage and CLX solution adversely affect the bond strength values compared to other subgroups / Doutor
135

Efeito da espessura oclusal do cimento e da sua união à cerâmica na resistência à fratura de coroas CAD/CAM: método de elementos finitos e testes monotônicos /

May, Liliana Gressler. January 2010 (has links)
Orientador: Marco Antonio Bottino / C0-orientador : Alvaro Della Bona / Banca: Luiz Felipe Valandro / Banca: Renata Marques de Melo Marinho / Banca: Ricardo Marins de Carvalho / Banca : Dolores Ribeiro Ricci Lazar / Resumo: Neste estudo avaliou-se a influência da espessura oclusal do cimento e de sua união à cerâmica na resistência à fratura de coroas CAD/CAM. O software COMSOL Multiphysics® foi utilizado para análise de elementos finitos (AEF) em modelos axi-simétricos bidimensionais de coroas de cerâmica vítrea estilizadas, com espessura oclusal de 1,5 mm, cimentadas à troqueis de material análogo à dentina quanto ao módulo elástico e potencial de união à resina composta (NEMA G-10 International Paper, USA). Variou-se as espessuras oclusais de cimento resinoso de 50 a 500 μm. Uma carga de 500 N foi aplicada com um pistão de extremidade circular plana (2 mm de diâmetro) sobre as coroas. A contração de polimerização do cimento foi simulada através de contração térmica. O contato entre cimento e cerâmica foi configurado para "união" e "ausência de união". O contato cimento-troquel foi sempre do tipo "união". As tensões dadas pela AEF foram utilizadas para o cálculo de cargas para fratura, levando-se em conta os efeitos deletérios da usinagem e do condicionamento ácido relatados na literatura. As coroas (Mark II, Vita Zhanfabrik, Germany) foram usinadas (CEREC InLab, Sirona, Germany), condicionadas e cimentadas (Multilink Automix, Ivoclar, Lietchstein) à troqueis de NEMA G-10 (n=6). Para a produção de corpos-de-prova na condição "ausência de união", aplicou-se uma fina película de poli(dimetilsiloxano) 30,000 cSt na superfície interna das coroas. As coroas foram submetidas à carregamento de 5N/s, com pistão de NEMA G-10, de extremidade plana e 2 mm de diâmetro. As fraturas radiais foram detectadas por sensor acústico. A magnitude das tensões resultantes da contração de polimerização dependeram da condição de união à cerâmica e da espessura oclusal de cimento. As cargas médias para fratura (N) de coroas com "união" ao cimento foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this study the influence of the occlusal cement thickness and its bonding to ceramic on the stresses and failure-loads of CAD/CAM crowns were evaluated. The software used for finite element analysis (FEA) was COMSOL Multiphysics®. Bi-dimensional axially symmetric models simulated stylized feldspathic crowns (1.5 mm occlusal thickness) with resin cement layers of 50 μm, 100 μm, 300 μm and 500 μm on dentin analog (NEMA G-10, International Paper, USA) under 500 N loading (2 mm diameter piston). Polymerization shrinkage of the cement layer was simulated as thermal contraction. Ceramic-cement interface was either bonded or not; cement-dentin was always bonded. Stress data were used for load-to-fracture predictions, using literature strengths accounting for milling and acid etching. Mark II® (Vita Zahnfabrik) crowns were milled (Cerec InLab®, Sirona), etched and cemented (Multilink Automix®, Ivoclar) to dentin analogs (NEMA G-10) (n=6). Non-bonding was achieved by applying a thin layer of 30,000 cSt poly(dimethylsiloxane) on the internal surface of the crowns. Crowns were loaded (5N/s) beneath a 2mm flat G-10 piston and radial cracks were detected acoustically. Stress magnitude resulting after cement shrinkage and loading depended on the bonding condition and on the cement thickness. Average failure loads (N) of bonded crowns were: 673.5 N for 50μm-cement thickness and 300.6 N for 500 μm. For non-bonded crowns, failure loads were 308,3 N, for 50 μm cement thickness and 233,3 N, for 500 μm. Bonded crowns presented failure loads at least two times higher than non-bonded, for 50 μm cement thickness, both experimentally and by FEA-based predictions. The benefit of bonding was lost when the cement was thicker than 500 μm. The resistance to fracture decreased with the cement thickness. Calculated loads based on FEA stresses and experimental data were comparable for the evaluate... (Complete abstract click electronic access below) / Doutor
136

Comportamento mecânico e características de desgaste de diferentes sistemas de encaixe utilizados em sobredentaduras mandibulares /

Mendoza Marin, Danny Omar. January 2017 (has links)
Orientador: Marco Antonio [UNESP] Compagnoni / Resumo: Uma ampla variedade de sistemas de encaixe para sobredentaduras retidas por implantes estão atualmente disponíveis no mercado. Estudos para avaliar o comportamento mecânico desses sistemas de encaixe tornam-se ainda necessários para uma maior compreensão das suas propriedades biomecânicas quando da sua indicação e seleção durante a confecção de sobredentaduras mandibulares. Objetivos: Avaliar a força de retenção inicial, resistência à fadiga, característica de desgaste e a influência da distância entre os implantes (16 mm, 22 mm e 29 mm) de diferentes sistemas de encaixe (O'ring, Bola Mini, Equator) utilizados em sobredentaduras mandibulares retidas por dois implantes. Metodologia: 90 corpos de prova foram confeccionados, os quais foram divididos em 09 grupos experimentais (n=10) de acordo com as distâncias estabelecidas e o sistema de encaixe. Os corpos de prova foram submetidos ao teste de fadiga mecânica utilizando a máquina de ensaios MTS 810 - Material Test System, durante 5500 ciclos de inserção/remoção (f = o,8 Hz), imersas em saliva artificial. Valores de retenção foram obtidos durante 4 períodos (0, 1500, 3000, 5500 ciclos) utilizando uma célula de carga de 1 kN e velocidade constante de 1mm/min. Um espécime de cada sistema de encaixe, utilizando a distância entre os implantes de 22 mm, foi selecionado de maneira aleatória e analisado por meio de um microscópio eletrônico de varredura para avaliação qualitativa da superfície. O teste de ANOVA dois e três fatores e o ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:Several attachment systems for mandibular overdentures retained by implants are currently available in the market. Studies to evaluate the mechanical behavior become necessary for a better understanding of the mechanical properties of these components, helping the surgeon dentist in the correct selection during the fabrication of mandibular overdentures. Objectives: To evaluate the initial retention force, fatigue strength, wear characteristic and the influence of the distance between the implants (16 mm, 22 mm and 29 mm) of different attachment systems (O'ring, Mini Ball, Equator) used in mandibular overdentures retained by two implants. Methodology: 90 specimens were fabricated and divided into 9 groups (n = 10) according to the established distances and the attachment system. A mechanical fatigue test was applied to the specimens using a universal testing machine MTS 810 - Material Test System performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group, using the distance between the implants of 22 mm, was randomly selected and analyzed by scanning electron microscopy for qualitative evaluation of surface. Twoway and Three-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). Results: For the distance of 22 mm, the O'ring system remained stable during all the periods tested and had the lowest retention values than Mini Ball and Equator systems (p<0.05). The Mini Ball system showed a significant increase in the retention force after the fatigue test (0 cycles = 21.04 ± 3.29; 5500 cycles = 24.01 ± 3.30). However, the Equator system showed a significant decrease in the retention...(Complete abstract electronic access below) / Doutor
137

Efeito da excitação ultrasônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro, após diferentes períodos de armazenamento

Azevedo, Elcilaine Rizzato [UNESP] 31 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-31Bitstream added on 2014-06-13T18:56:30Z : No. of bitstreams: 1 azevedo_er_me_arafo.pdf: 268574 bytes, checksum: 3acb7b065102ea435408134a95258b11 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo investigou o efeito da excitação ultra-sônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro (CIV), após 24 horas ou 30 dias de armazenamento em água destilada à 37ºC, por meio do teste de microtração. Os materiais utilizados foram o CIV de alta viscosidade Fuji IX GP, Ketac Molar e o modificado por resina, Vitremer. Foram confeccionados 12 corpos de prova para cada material, dos quais 6 formaram o grupo controle e 6 receberam tratamento com US, por 30 segundos. Para o experimento de resistência de união à dentina, trinta e seis terceiros molares foram divididos aleatoriamente entre os grupos experimentais já descritos. Em ambos os experimentos, após o período de armazenamento, os corpos de prova foram seccionados em espécimes com área adesiva média de 0,91mm2 (± 0,1) e 0,93 mm2 (± 0,09), respectivamente para o experimento de resistência à tração e de união. Os dados foram analisados pela análise de variância com a correção de Welch (p<0,001) e teste de Tamhane (α = 0,05). O cimento Fuji IX (24 horas) apresentou aumento significativo na resistência máxima à tração e o Ketac Molar (24 horas) na resistência de união à dentina, após a aplicação do US. Os grupos controle destes materiais também apresentaram aumento da resistência após 30 dias de armazenamento. Em todos os outros grupos experimentais não houve alteração significativa após a aplicação de US ou após diferentes períodos de armazenamento. A aplicação do ultra-som aumentou a resistência máxima à tração e de união à dentina, após 24 horas de armazenamento, quando se utilizou respectivamente, os cimentos Fuji IX e Ketac Molar. / This study investigated the GICs ultimate tensile strength and bond to dentine after ultrasonic excitation and after periods of the 24 hours and 30 days storage in distilled water at 37ºC, using microtensile test. Two high viscosity GICs, Fuji IX GP and Molar Ketac, and the resin modified GIC Vitremer were used. Twelve specimens for each material were prepared, 6 formed the control group and 6 received treatment with US, por 30 seconds. For the ultimate tensile strength experiment, a cross-sectional area of 0.91mm2 (± 0.1) in the specimens were obtained. For the tensile bond strength to dentine test, 36 third molar were selected and randomly divided into groups, with a cross-sectional area of 0.93 mm2 (± 0.09). All specimens were tested in a microtensile test machine. The data were evaluated by analysis of variance and corrected by Welch (p<0.001) and Tamhane tests (α = 0.05). Fuji IX (24 hours) had significant increase in the ultimate tensile strength and Ketac Molar (24 hours) had significant increase in the tensile strength of union to dentine, after the application of the US. The control groups of the Fuji IX and Ketac Molar had increase in the tensile strength after 30 days of storage. All the other groups, did not show significant difference neither when US application was used nor between different storage times. The ultrasound application increased the ultimate tensile strength and bond to the dentine, after 24 hours of storage, when if it used respectively, the Ketac Molar and Fuji IX cements.
138

Inter-relação do comprimento dos prolongamentos resinosos (tags) e da espessura da camada híbrida de adesão, com a resistência de união de sistemas adesivos ao tecido dentinário

Rahal, Vanessa [UNESP] 06 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-06Bitstream added on 2014-06-13T19:10:17Z : No. of bitstreams: 1 rahal_v_me_araca.pdf: 1283772 bytes, checksum: 8c48fcbb5450bb565918794bd4285d39 (MD5) / O objetivo deste estudo foi analisar a correlação da espessura da camada híbrida de adesão e do comprimento dos prolongamentos resinosos (tags), com a resistência de união em tecido dentinário hígido, de um sistema adesivo convencional e de outro autocondicionante. Após a realização “in vivo” dos procedimentos restauradores, os dentes foram extraídos e seccionados no sentido mésio/distal. Em uma secção dental foi realizada a análise microscópica dos prolongamentos resinosos e da camada híbrida de adesão. Para tanto, os espécimes foram descalcificados, incluídos em parafina e cortados a uma espessura de 6 μm. Os cortes foram corados pelo método Brown e Brenn, para posterior análise e mensuração em microscópio óptico comum Axiophot Zeiss em 1000× (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). O remanescente dental foi acoplado à cortadeira metalográfica ISOMET 1000 (Buehler, Lake Bluff, IL, USA), de forma a permitir a realização de secções transversais, destinados ao teste de microtração (Instron modelo 4411 - Instron Inc., Canton, MA, EUA), sendo tracionados a 0,5 mm/min até sua ruptura. A superfície fraturada foi classificada segundo o padrão de fratura após análise sob lupa estereoscópica Stemi SV 11 (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden-Württemberg, Germany) em aumento de 40×. Os valores obtidos no teste de microtração, na análise dos tags e da camada híbrida correspondentes a cada espécime e grupo de estudo, foram submetidos à análise estatística, com a realização do teste de Correlação de Pearson, não sendo verificada correlação entre os valores de resistência de união e a espessura da camada híbrida e comprimento dos tags resinosos em nenhum dos sistemas adesivos estudados. / The purpose of this study was to evaluate the possibility of the correlation between the hybrid layer thickness, the resin tag length, and the resin bond strength of a conventional and a self-etching adhesive system into sound dentin tissue. After “in vivo” restorative procedures were performed, each specimen was extracted and sectioned in a mesiodistal direction. One of the dental sections was then analyzed on a light microscope where the hybrid layer thickness and resin tag length were measured. For this experiment, the specimens were decalcified, embedded in paraffin and serially sectioned at a thickness of 6 μm. The sections were subsequently stained using Brown and Brenn stain for posterior analysis and for the measurement of the hybrid layer thickness and the resin tag length on a Zeiss Axiophot light microscope at 1000× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The other section was mounted onto a metallographic cutter ISOMET 1000 (Buehler, Lake Bluff, IL, USA) and was sectioned. A microtensile test was subsequently performed (Instron modelo 4411 - Instron Inc., Canton, MA, USA) with a crosshead speed of 0.5 mm/min. The fractured surfaces were analyzed and the fracture pattern was characterized using a stereoscopic magnifying glass Stemi SV 11 at a 40× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The results were subjected to Pearson Correlation Test and verified that the hybrid layer thickness and the resin tag length did not correlate with the bond strength of the adhesives systems.
139

Resistência de união de um sistema adesivo irradiado com laser Nd:YAG em dentina tratada com laser de Er:YAG

Malta, Daniel Alexandre Menezes Pedrosa [UNESP] 27 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-27Bitstream added on 2014-06-13T19:51:20Z : No. of bitstreams: 1 malta_damp_me_arafo.pdf: 3852992 bytes, checksum: d55fbc5b212b5a71eaa602dda984e5e6 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A proposta deste estudo foi avaliar por meio do teste de microtração a resistência de união de um sistema adesivo irradiado com laser de Nd:YAG em dentina preparada com laser de Er:YAG. Estudos prévios têm demonstrado que a irradiação com laser após a aplicação do sistema adesivo é eficiente em alcançar alta força de união à tensão e ao cisalhamento. O laser de Er:YAG (Twinlight, Fotona, Eslovênia) com fluência de 60 J/cm2 foi usado para o tratamento da dentina. A irradiação do adesivo foi realizada usando o laser de Nd:YAG (Twinlight, Fotona, Eslovênia) com fluência de 100 J/cm2. As restaurações foram executadas com Adper Single Bond 2/Z250 (3M/ESPE, EUA). Vinte terceiros molares recentemente extraídos e livres de cárie foram empregados. Os dentes foram divididos em quatro grupos experimentais (n = 5): (G1) grupo controle onde não houve irradiação; (G2) irradiação do sistema adesivo com laser de Nd:YAG; (G3) tratamento da dentina com laser de Er:YAG; (G4) tratamento da dentina com laser de Er:YAG mais irradiação do sistema adesivo com laser de Nd:YAG. Um dente de cada grupo foi preparado para avaliação da interface adesiva sob microscopia eletrônica de varredura (MEV). Adicionalmente foi realizada a análise do padrão de fraturas, resultante dos ensaios mecânicos, sob microscopia óptica digital. Os testes de microtração foram realizados em uma máquina de ensaios mecânicos com célula de carga de 1 kN a uma velocidade de 0,5 mm/min. A análise estatística (ANOVA e teste de Tukey), dos dados referentes aos ensaios mecânicos, evidenciaram diferença estatística significante entre os grupos G1 e G3, G1 e G4, G2 e G3, e G2 e G4 e semelhança entre os grupos G1 e G2, e G3 e G4. As fraturas adesivas foram predominantes em todos os grupos experimentais. / The purpose of this study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine treated with Er:YAG laser. Previous studies had shown that laser irradiation after the application of an adhesive system is efficient in achieving higher shear bond and tensile bond strength. Er:YAG laser (Twinlight, Fotona, Slovenia) with fluency of the 60 J/cm2 was used for the treatment of the dentine. The irradiation of the adhesive was performed using the Nd:YAG laser (Twinlight, Fotona, Slovenia) with the fluency of the 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250 (3m/ESPE, USA). Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group where there was no irradiation; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) treatment of the dentin with Er:YAG laser; (G4) treatment of the dentin with Er:YAG laser plus irradiation of the adhesive system with Nd:YAG laser. One tooth of each group was prepared for evaluation of adhesive interface under scanning electron microscopy (SEM). In addition was performed an evaluation of the bond failures under digital optic microscopy. The micro tensile bond tests were performed in a MTS universal testing machine with 1 kN load cell at cross-head speed 0,5 mm/min. The statistical analysis (ANOVA and Tukey test) showed difference significant statistics between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all experimental groups.
140

Avaliação da microinfiltração marginal e da resistência adesiva em dentes restaurados com inlays de resina composta. Efeito da hibridização imediata do preparo cavitário

Freitas, Cláudia Regina Buainain de [UNESP] 27 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-27Bitstream added on 2014-06-13T20:51:31Z : No. of bitstreams: 1 freitas_crb_me_arafo.pdf: 1243419 bytes, checksum: 9b17396cab68dbc46f7018d3bc8aec44 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o procedimento de hibridização imediata em restaurações indiretas de resina composta. A hipótese nula foi duplicada: os resultados dos adesivos de condicionamento total e auto-condicionante são similares; e a hibridização imediata produz microinfiltração e resistência adesiva similares à cimentação convencional. Foram selecionados 20 terceiros molares humanos recém extraídos e isentos de cárie, nos quais foram realizados preparos cavitários MOD, padronizados para restaurações indiretas. Os dentes foram divididos aleatoriamente em 4 grupos experimentais: (G1) hibridização com adesivo de condicionamento total (SB, Single Bond, 3M ESPE) imediatamente após o preparo cavitário e antes da cimentação, (G2) hibridização com adesivo de condicionamento total antes da cimentação (SB), (G3) hibridização com adesivo auto-condicionante (AP, Adper Prompt, 3M ESPE) imediatamente após o preparo cavitário e antes da cimentação, (G4) hibridização com adesivo auto-condicionante (AP) antes 157 da cimentação. Os espécimes foram restaurados com inlays de Targis (Ivoclar/Vivadent), cimentados com cimento resinoso Rely X ARC (3M ESPE). Todos produtos foram manipulados de acordo com as instruções do fabricante. Após termociclagem, os espécimes foram imersos em solução de nitrato de prata 50%, seccionados para avaliação da microinfiltração com escores pré-determinados de 0 a 3. Em seguida, os espécimes foram novamente seccionados com 0,8mm x 0,8mm para realização dos testes de microtração. Os resultados obtidos foram submetidos à análise estatística (p<0,05). Os escores da microinfiltração foram submetidos ao teste de Mann-Whitney indicando nenhuma diferença na técnica de hibridização (p>0,05). Os resultados da microtração foram submetidos à análise de variância que revelou... . / An analysis was carried out to determine the behavior of immediate hybridization on indirect composite resin restorations. The null hypothesis was two fold: were whether total etch or self-etch (SEA) adhesives result in similar; and whether immediate hybridization produces similar microleakage and æTBS than conventional cementation. Twenty sound extracted teeth were selected and 20 standardized MOD inlay preparations were made. The prepared teeth were randomly assigned in four experimental groups: (G1) hybridization with total-etch adhesive (SB, Single Bond, 3M ESPE) immediately after preparation and prior cementation, (G2) hybridization with total-etch adhesive prior cementation (SB), (G3) hybridization with SEA (AP, Adper Prompt, 3M ESPE) immediately after preparation and prior cementation; and (G4) hybridization with SEA (AP) prior cementation. The specimens were restored with Targis (Ivoclar/Vivadent) inlays, cemented with composite resin cement (RelyX ARC, 3M ESPE). All products were used according with manufacturer's instructions. The specimens were 160 thermocycled and immersed in 50%w/w silver nitrate. The specimens were sectioned and the microleakage evaluated with predetermined scores (0-3). Then, the specimens were sectioned in 0,8mm x 0,8mm and æTBS tested in a MTS-810 machine. The obtained data were submmited to statistical analysis (p< .05). The microleakage scores were submmited to Mann-Whitney non-parametric test showing no statistical differences among the adhesives and technique (p> .05). The æTBS results submitted to ANOVA parametric test reveled that G1 performed better than G2, and G3 superior to G4. The null hypotheses were partially rejected. None of the adhesives eliminate microleakage. Hybridization immediately after the preparation is done and before cementation improved the bond strengths with... (Complete abstract, click electronic address below).

Page generated in 0.0811 seconds