• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 706
  • 29
  • 9
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 756
  • 461
  • 128
  • 90
  • 86
  • 84
  • 77
  • 77
  • 75
  • 67
  • 61
  • 59
  • 56
  • 54
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Impacto do ruído ambiental da unidade de terapia intensiva neonatal sobre as respostas de estresse em recém-nascidos prematuros

BEZERRA, Andrezza de Lemos 15 March 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-28T21:31:36Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Andrezza de Lemos Bezerra.pdf: 2887327 bytes, checksum: 954c2f25345d9c74c453c843d64312e1 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-22T20:12:58Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Andrezza de Lemos Bezerra.pdf: 2887327 bytes, checksum: 954c2f25345d9c74c453c843d64312e1 (MD5) / Made available in DSpace on 2018-11-22T20:12:58Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Andrezza de Lemos Bezerra.pdf: 2887327 bytes, checksum: 954c2f25345d9c74c453c843d64312e1 (MD5) Previous issue date: 2017-03-15 / Unidades de terapia intensiva neonatais são ambientes onde há estimulação excessiva e podem interferir no curso normal de desenvolvimento de prematuros. O presente trabalho teve como objetivo avaliar o nível de pressão sonora de uma unidade de terapia intensiva neonatal de referência e avaliar as respostas fisiológica e motora de recém-nascidos prematuros, desencadeada por um estímulo estressante, através da exposição ao ruído, em uma unidade de terapia intensiva neonatal. Foi realizado um estudo observacional em duas etapas: avaliação do ruído ambiental da unidade e avaliação da resposta neonatal de estresse. Para a primeira etapa, foi utilizado um decibelímetro para mensurar o nível de pressão sonora a cada 5 segundos, por 24h, durante uma semana. Durante o período do estudo foram entrevistados pais e profissionais inseridos na unidade sobre a percepção do ruído. Para a segunda etapa, foram incluídos prematuros com idade gestacional inferior a 37 semanas, de ambos os sexos, com indicação de aspiração naso ou endotraqueal, que estavam em uso do aspirador de ar comprimido, em três momentos: antes, durante e após a exposição ao ruído do aspirador. A avaliação da resposta fisiológica constou dos parâmetros fisiológicos frequência cardíaca (FC),frequência respiratória (FR) e saturação periférica de oxigênio (SpO2). Para aavaliação motora, foram obtidas 3 filmagens do recém-nascido, de 5 minutos cada, para a quantificação de repetições de movimentos relacionados a estresse apresentados pelo recém-nascido pré-termo. Além da resposta motora, também foi aplicada uma escala para avaliação de dor. Os valores médios registrados em todos os períodos (manhã, tarde, noite e madrugada) permaneceram acima de 60 dB (66,5 ± 1,255; 66,0 ± 1,199; 65,5 ± 1,164; 64,2 ± 0,975, respectivamente). Não houve diferença significativa entre o período da manhã, tarde e noite, sendo a madrugada o momento menos ruidoso. Sobre a resposta fisiológica, foi verificado um aumento significativo na FR, quando comparados os momentos antes e durante (47,09 ± 11,97 e 49,49 ± 13,34; p<0,02). Não houve alteração significativa da FC e SpO2 quando comparados os momentos antes, durante e depois. Acerca da resposta motora, foi observado um aumento significativo na contagem total de movimentos, na frequência de extensão de perna e extensão de braço, quando comparados os momentos antes e após a exposição ao ruído (p< 0,05). Porém, não houve variabilidade do percentual de recém-nascidos que apresentaram dor, quando comparados os momentos antes, durante e depois (p=0,704). Os níveis de ruído encontrados em todos os turnos estavam acima do recomendado, o que reforça a necessidade de implementação de medidas de humanização e conscientização para minimizar os efeitos nocivos causados pelo ruído, considerando que os dados das avaliações fisiológica e motora sugerem que, mesmo de curta duração, uma exposição a ruído torna-se um estímulo estressor e pode alterar a FR do prematuro, levando ao seu incremento, além de aumento da frequência de determinados movimentos relacionados a estresse, principalmente extensão de pernas e braços, com consequente aumento do trabalho respiratório, gasto energético e reforço de padrões motores anormais. / Neonatal intensive care units are environments where there are excessive stimuli that may interfere in normal course of the development of premature infant. The present study aimed to evaluate noise level in a neonatal intensive care unit and to assess physiological and motor responses of premature infants due to stressful stimuli, by noise exposure, at a neonatal intensive care unit. A two phase observational study was conducted: unit´s environmental noise level evaluation and assessment of the neonatal stress response. For the first stage, a sound level meter was used to measure the level of sound pressure, every 5 seconds, for 24h, during one week. At this period, parents and professionals of the unit were interviewed about the perception of noise. For the second stage, premature infants, both genders, who had indication of suctioning, were included and evaluated in three moments: before, during and after the suctioning device noise exposure. Assessment of the physiological response consisted of heart rate (HR), respiratory rate (RR) and peripheral oxygen saturation (PO2S). For the motor evaluation, 3 films of the newborn were obtained, 5 minutes each, to quantify repetition of movements related to stress. It was also applied a pain assessment scale. Median registered values of sound pressure level in all periods (morning, afternoon, night, early morning) remained above 60dB (66,5 ± 1,255; 66,0 ± 1,199; 65,5 ± 1,164; 64,2 ± 0,975, respectively). There was not a significant difference among morning, afternoon and night, the less noisy moment was early morning. About the physiological response, there was a significant increase in RR, when compared before and during noise exposure (47,09 ± 11,97 e 49,49 ± 13,34; p<0,02). There was not a significant alteration of HR nor PO₂S among different moments. About motor response, it was observed a significant increase of total movements count, leg extension and arm extension frequencies, when the moments before and after noise exposure were compared (p< 0,05). Nevertheless, there was not variability of the percentage of newborns who presented pain reaction, among moments comparison (p= 0,704). The noise levels found in all periods were above recommended threshold, that reinforces need for implementation of humanization and awareness measures to minimize noxious effects of noise, considering that data of physiological and motor responses suggest that, even a short exposure, to a noise stressor may alter the premature infant’s RR, leading to its rise, beyond the increase in frequency of specific movements related to stress, mainly leg and arm extensions, with consequent increase in work of breath, energy expenditure and reinforcement of abnormal motor patterns.
142

"Ruído na unidade de cuidado intermediário neonatal de um hospital universitário de Ribeirão Preto-SP" / Noise at the intermediary neonatal care unit of a university hospital in Ribeirão Preto-SP.

Zamberlan, Nelma Ellen 09 June 2006 (has links)
Trata-se de um estudo quantitativo descritivo, exploratório e observacional cujo objetivo foi determinar os níveis de ruído ambiente na unidade de cuidado intermediário neonatal de um hospital universitário de Ribeirão Preto-SP e dimensionar os níveis de pressão sonora (NPS) gerados em decorrência de ar condicionado, lâmpadas da enfermaria e monitor de apnéia ligados; alarme acionado; torneira da pia aberta; manejo da lixeira; conversas entre profissionais (visita médica e passagem de plantão da enfermagem) e ruídos externos (abrir e fechar a porta de acesso à unidade neonatal e conversação na ante-sala). O ruído ambiente foi dimensionado na enfermaria de manipulação mínima da unidade de cuidado intermediário neonatal, em duas semanas consecutivas, sendo 12 horas por dia no período diurno das 7 às 19 horas na primeira semana e 12 horas no noturno, diariamente das 19 às 7 horas, na segunda semana. Utilizou-se o medidor de NPS, o dosímetro Quest-400, posicionado na área central da enfermaria e suspenso a 70 cm do teto. Para dimensionar cada ruído interno e externo, discriminado no segundo objetivo, mantiveram-se na enfermaria os mesmos bebês ali internados e somente a pesquisadora, evitando-se a presença de outros ruídos audíveis. Mensurou-se os NPS por três minutos consecutivos, exceto a passagem de plantão da enfermagem que incluiu três momentos de medida, sendo uma para cada final de turno de trabalho. Para análise dos dados utilizou-se o programa QuestSuiteMR para processar os NPS em respostas numéricas e transportar em planilhas no software Excel 2003 e SPSS (Statiscal Package for the Social Sciences). O nível médio de ruído na unidade foi de 60,8dBA. A variabilidade do Leq na semana foi de 20,8dBA (51,8 a 72,6dBA), Lpeak 23,6dBA (90,1 a 113,7dBA), Lmax 42,8dBA (52,1 a 90,9dBA) e do Lmin foi de 1,4dBA (50,7 a 52,1dBA). As hipóteses de que mesmo em enfermaria de manipulação mínima o ruído é intenso e que a fonte de ruído mais intensa é o abrir e fechar a tampa da lixeira (Leq médio de 59,3dBA) foram confirmadas. A porta aberta da enfermaria permitiu maior entrada de ruído externo gerado na ante-sala, em especial aquele decorrente de abrir e fechar a porta de correr de acesso à unidade neonatal (57,3dBA). Assim, confirmou-se a terceira hipótese, que o ruído ambiente diminui ao fechar a porta de acesso à enfermaria. Confirmou-se também a quarta hipótese, que a conversa entre os profissionais na passagem de plantão da enfermagem e visita médica constitui fonte de ruído intenso, sendo que os maiores Leq foram de 63,8dBA em ambas situações. Concluiu-se que os NPS foram intensos em todos os turnos e dias da semana da coleta de dados, estando acima das recomendações e normas técnicas para níveis de ruído adequados em unidades neonatais. Com base nos resultados e na literatura elaborou-se um protocolo para controlar o excesso de estímulos sonoros ambientais, incluindo um conjunto de ações intersetoriais dirigidas à infra-estrutura física, aos recursos tecnológicos e humanos (profissionais e familiares). / This descriptive, exploratory and observational quantitative study aimed to determine ambient noise levels at the intermediary neonatal care unit of a university hospital in Ribeirão Preto-SP and dimension sound pressure levels (SPL) produced by air-conditioning, lamps at the nursing ward and the functioning of apnea monitors; alarms going off; open water taps; handling of garbage cans; conversations among professionals (medical visit and nursing shift change) and external noise (opening and closing the access door of the neonatal unit and conversation in the antechamber). Ambient noise was dimensioned at the minimal manipulation nursing ward in the intermediary neonatal care unit of the university hospital in Ribeirão Preto-SP for two consecutive weeks. In the first week, ambient noise levels were measured every day for 12 hours, from 7 a.m. to 7 p.m. In the second, ambient noise was measured every night for 12 hours, from 7 p.m. to 7 a.m. A Quest-400 dosimeter was used to measure SPL, placed in the center of the ward and hung from the roof at 70 cm. To dimension each internal and external noise distinguished in the second objective, only the hospitalized babies and the researcher continued at the ward, avoiding the presence of other audible noise. Sound pressure levels were measured for three consecutive minutes, except during nursing shift changes, including three measurement moments, one at the end of each shift. For data analysis, QuestSuiteMR was used to process SPL in numerical answers and move them to Excel 2003 and SPSS (Statistical Package for the Social Sciences) worksheets. The mean sound level at the unit was 60.8dBA. A variability of 20.8dBA (from 51.8 to 72.6dBA) was found for Leq, 23.6dBA (90.1 to 113.7dBA) for Lpeak, 42.8dBA (52.1 to 90.9dBA) for Lmax and 1.4dBA (50.7 to 52.1dBA) for Lmin. The results confirmed the hypotheses that noise is intense, even at a minimal manipulation ward, and that opening and closing the garbage can is the most intense noise source (mean Leq 59.3dBA). The open door of the nursing ward allowed more external noise from the antechamber to enter, especially noise produced by opening and closing the running door that gave access to the neonatal unit (57.3dBA). This confirmed the third hypothesis, that is, that environmental noise decreases when the door of the nursing ward is closed. The fourth hypothesis was also confirmed, i.e. that conversations between professionals during shift changes and medical visits were a source of intense noise. The highest Leq corresponded to 63.8dBA in both situations. Sound pressure levels were intense across all shifts and days of the data collection period, exceeding recommendations and technical standards for adequate noise levels at neonatal units. Based on these results and on literature, a protocol was elaborated to control the excess of ambient noise stimuli, including a set of intersectorial actions directed at physical infrastructure, technological and human resources (professionals and family members).
143

Níveis de ruído de incubadoras em situações experimentais de manejo: subsídios para o cuidado em unidades neonatais / Levels of noise in incubators in experimental handling situations: evidences for care in neonatal units.

Miranda, Andreza Monforte 20 March 2009 (has links)
Introdução. Pensar nos efeitos nocivos do ruído aos recém-nascidos (RN) com saúde debilitada se torna cada vez mais necessário devido aos avanços tecnológicos, ao aumento da sobrevida dos RNs de baixo peso, com maiores períodos de hospitalização. Objetivo geral. Avaliar os níveis de ruído das incubadoras das unidades neonatais de um hospital universitário de Ribeirão Preto, SP, em situações experimentais de manejo. Método. Trata-se de estudo quantitativo do tipo quase-experimental, realizado com 20 incubadoras das unidades neonatais de um hospital universitário de Ribeirão Preto, SP, que se encontravam disponíveis durante o período de coleta de dados. O período de coleta foi de agosto a setembro de 2008. As incubadoras foram divididas em três grupos (1, 2, 3), conforme a marca, o modelo, tempo de uso e situação de manejo. As medidas foram realizadas sem a presença do RN, em uma sala afastada do fluxo rotineiro das unidades neonatais. Foi utilizado um dosímetro, modelo Quest 400, com o microfone fixado dentro da incubadora para mensurar o Nível de Pressão Sonora (NPS). Foram realizadas as mensurações dos níveis de ruído contínuo (funcionamento do motor, alarme soando, pulso oxímetro e bomba de infusão sobre a cúpula e seus alarmes) e de impacto (manipulação da portinhola e ato de colocar o frasco de álcool gel sobre a cúpula) nas incubadoras. Os ruídos de impacto foram analisados nos modos de manipulação cuidadoso e brusco. As medidas com o pulso oxímetro, bomba de infusão e o ato de colocar o frasco de álcool gel sobre a cúpula foram repetidas com a presença do cueiro sobre a cúpula da incubadora. Os valores mensurados de Leq, Lmax, Lmin dos ruídos contínuos e os valores de Lpeak dos ruídos de impacto foram analisados por meio dos valores medianos, mínimos e máximos. Resultados. Os valores medianos gerais dos três grupos encontrados para ruído contínuos foram: Leq de 55,2dBA para ruído de funcionamento das incubadoras; Leq 65,5dBA de para alarme da incubadora; para pulso oxímetro e alarme e bomba de infusão e seu alarme os Leq foram: 54,7dBA, 58,4dBA, 53,9dBA e 66,1dBA NPS, respectivamente. Com cueiro, os valores nessas situações foram: 54,0dBA, 57,8dBA, 55,1dBA e 61,7dBA NPS, respectivamente. Todos Lmax medianos de cada grupo nas situações anteriormente descritas estiveram acima de 65dBA e os Lmin acima de 47dBA. Os ruídos de manipulação alcançaram valores de Lpeak medianos gerais para os três grupos de 91,2dBA e 97,9dBA NPS para abrir a portinhola nos modos cuidadoso e brusco e 91,5dBA e 109,5dBA NPS ao fechar cuidadoso e brusco a portinhola, respectivamente. Os níveis atingidos ao colocar o álcool gel sobre a cúpula no modo cuidadoso com e sem cueiro variaram de 89dBA a 89,6dBA NPS e no modo brusco com e sem cueiro de 107dBA a 107,7dBA. Conclusão. Os níveis gerados pelas incubadoras e seus alarmes estão abaixo daquele recomendado pelas normas nacionais, mas acima da norma internacional. A presença de equipamentos sobre a cúpula e seus alarmes soando não intensificaram os níveis de ruído nas incubadoras, com exceção do alarme da bomba de infusão. Os níveis de ruído produzidos pela manipulação da incubadora e o ato de colocar o álcool gel sobre a cúpula foram intensos e o modo cuidadoso foi um recurso para diminuir os níveis sonoros. De um modo geral, o uso do cueiro não reduziu o ruído gerado pelos equipamentos sobre a cúpula e nem o ruído gerado pelo ato de colocar o álcool gel sobre a cúpula. / Introduction. Technological advances and increase in survivorship of low birth weight newborns (NB), with longer periods of hospitalization, make each time more necessary to think about the noxious effects of noise to NB with weak health. Objective. to evaluate levels of noise in incubators of neonatal units in experimental handling situations, in a university hospital in Ribeirão Preto, state of São Paulo, Brazil. Method. Quantitative quasiexperimental study, carried out in 20 incubators in neonatal units during the data collection period, from August to September 2008, in a university-hospital in Ribeirão Preto, SP. Incubators were divided into three groups (1,2,3), according to brand, model, usage time and handling situation. Measuring occurred when NB were not in incubators, in a room far from usual neonatal unit routine work. A Quest 400 dosimeter with microphone fixed inside incubator was used to measure Sound Pressure Level (SPL). Levels of continuous noise (motors functioning, alarm sound, pulse oximeter and infusion bombs on the incubator dome and their alarms) and impact noise (manipulation of incubators door and putting the bottle of alcohol gel on the dome) in incubators were measured. Impact noises were analyzed for careful and rough manipulation. Measures with pulse oximeter, infusion bomb and putting the bottle of alcohol gel on the incubator dome were repeated with a swathe placed on the dome. Continuous noise Leq, Lmax, Lmin and impact noise Lpeak values measured were analyzed using mean, minimum and maximum values. Results. General mean values found for continuous noise in the three groups were: Leq intensity of 55,2dBA for incubators functioning noise; Leq 65,5dBA for incubators alarm; for pulse oximeter, alarm, infusion bomb and infusion bombs alarm Leq were: 54,7dBA, 58,4dBA, 53,9dBA and 66,1dBA SPL, respectively. Using a swathe, values in the same situations were: 54,0dBA, 57,8dBA, 55,1dBA and 61,7dBA SPL respectively. All mean Lmax for each group in the previously described situations were over 65dBA and Lmin over 47dBA. Manipulation noises reached Lpeak general mean values for the three groups of 91,2dBA and 97,9dBA SPL for rough and careful opening of incubator door, and 91,5dBA and 109,5dBA SPL for careful and rough closing, respectively. Levels reached for putting alcohol gel on the incubator dome carefully, with or without swathe, varied from 89dBC to 89,6dBC SPL, and roughly, with or without swathe, varied from 107dBC to 107,7dBC. Conclusion. Noise levels generated by incubators and alarms are under national rules, but over international rules. The presence of equipments on the dome and the sound of incubator alarm do not increase the levels of noise in incubators, with exception of infusion bombs alarm. Noise levels produced by incubator manipulation and putting alcohol gel on the incubator dome are intense, careful mode was a way to decrease noise levels. In a general way, the use of a swathe did not reduce noise generated by the equipments on the dome neither noise of putting alcohol gel on the dome.
144

A methodology for noise prediction of turbofan engines.

Gustavo Di Fiore dos Santos 29 May 2006 (has links)
A computional model is developed for prediction of noise emission from na existing or new turbofan engine. This model allows the simulation of noise generation from high bypass ratio turbofan engines, appropriate for use with computational programs for gas turbine performance developed at ITA. Analytical and empirical methods are used for spectrum shape, spectrum level, overall noise and free-field directivity noise. The most significant noise sources in turbofan engines are modeled: fan, compressor, combustion chamber, turbine, jet (separate streams or mixed jet), with corrections for forward speed, atmospheric attenuation, ground reflection, and nacelle acoustic treatment (perforate liners). The procedures for component noise prediction are combined to yield total turbofan engine noise emission, as a funtion of engine operation condition and of observer (distance and directivity angle).
145

Estimativa de ruído gerado por turbinas a gás em operação utilizando modelos empíricos.

Daniel Jonas Dezan 28 January 2011 (has links)
Modelos para a previsão de ruído gerado por motores a jato, como turbofan de alta razão de bypass, são utilizados neste trabalho. Estes modelos, em conjunto com programas computacionais desenvolvidos no ITA, simulam a geração de ruído em cada componente do motor e, então, determinam o ruído total irradiado. Métodos empíricos são utilizados na determinação do nível de pressão sonora para cada banda de 1/3 de oitava, em função da direcionalidade da fonte de ruído e da distância do observador até a fonte. A importância da previsão de ruído gerado por motores aeronáuticos é ressaltada, sobretudo nos critérios que tangem a certificação de aeronaves comerciais. Os componentes principais a serem estudados são: fan/compressor, câmara de combustão, turbina e bocal propulsor (jato simples). Resultados para jatos simples são comparados com dados da literatura e para um motor tipo turbojato novo são obtidos. A simulação de funcionamento do motor completo, para gerar dados do escoamento para o cálculo do ruído, é comentada. Os dados de propriedades do escoamento e de projeto do motor são feitos de modo a obterem as informações necessárias a cada modelo de previsão de ruído. Os modelos utilizados para previsão de ruído de compressor, de câmara de combustão, de turbina e de jato simples são respectivamente NASA TM-195480, SAE ARP-876D, NASA-ANOPP e ESDU Item 98019. Um módulo capaz de calcular o nível de ruído produzido por um motor é incorporado ao programa de simulação numérica de funcionamento de turbinas a gás, sendo capaz de predizer os níveis de ruído em condições de operação fora do ponto de projeto. Espera-se, com isto, obter informações importantes sobre ruído, na fase de projeto do motor e/ou para subsidiar proposições para a sua redução.
146

Estimação de ruído de motores turbofan instalados em aeronaves de transporte

Daniel Amado Muraro 22 June 2009 (has links)
A importância de se desenvolver aeronaves com baixos níveis de ruído interno e externo já é uma cultura generalizada na comunidade aeronáutica e de aviação. Aeronaves ruidosas podem ser simplesmente banidas de operar em determinados aeroportos ou pagar taxas maiores para poder operar em vários outros. Neste contexto, para auxiliar o projeto de aeronaves menos ruidosas, o presente trabalho ocupa-se com o desenvolvimento de uma ferramenta numérica para estimação de ruído externo gerado por motores turbofan instalados em aeronaves. Um código computacional foi desenvolvido seguindo a metodologia de alguns relatórios NASA TM-X para fornecer uma estimativa de ruído em volta da aeronave em distâncias desejadas pelo usuário. Cada relatório aborda um componente específico do motor, a saber, entrada de ar, câmara de combustão, turbina e bocal de exaustão. O código foi implantado na plataforma MATLAB visando à integração com rotinas de projeto e otimização já existentes, escritas nesta linguagem. O código foi validado com uma comparação com a metodologia ESDU e com um trabalho semelhante desenvolvido na Universidade de Berlin, e suas aplicações em projeto de aeronave são exemplificadas e discutidas no presente trabalho.
147

Otimização de trajetória de decolagem para a minimização do ruído externo

Juliano de Melo Lustosa 13 April 2010 (has links)
A redução dos impactos ambientais ocasionados pela operação de aeronaves vem sendo alvo de interesse. Neste contexto, insere-se a redução dos níveis de ruído permitidos em pousos e decolagens devido ao crescimento do número de residências próximas a aeroportos. Nessas regiões, há sensores estrategicamente localizados capazes de medir o ruído, acarretando pesadas multas aos operadores caso desrespeitem certos limites. Isto exige que sejam encontradas alternativas para aeronaves cujos projetos são antigos, quando limites impostos pelas autoridades aeronáuticas eram mais brandos. Uma medida é atuar sobre os comandos da aeronave, executando procedimentos de decolagem e pouso com nível de ruído percebido EPNL (&quot;Effective Perceived Noise Level&quot;) em dB reduzido. Neste trabalho analisa-se a trajetória de decolagem em busca de uma solução ótima que minimiza o ruído no ponto de interesse nesta fase de vôo. A dinâmica do problema é modelada através de equações diferenciais de movimento tridimensional e massa da aeronave concentrada, sem levar em conta sua dinâmica de corpo rígido já que esta não influencia no modelo de predição de ruído. Considera-se como fonte de ruído apenas os motores. Através de restrições não lineares, garante-se que a trajetória otimizada respeita limites físicos da aeronave. A atmosfera é modelada sem vento e segue o modelo de atmosfera padrão da ICAO, amplamente utilizado pela indústria em cálculos de desempenho. Por sua vez, o modelo dos motores é construído com curvas de tração em função de altitude e Mach de vôo, as quais provêm de dados conhecidos de motores reais, cujos valores serviram para ajustar um modelo termodinâmico teórico de motor turbojato. Parâmetros do modelo como a massa da aeronave, suas dimensões e suas características aerodinâmicas foram tomadas de um avião bimotor a jato de pequeno porte, cujos dados foram encontrados na literatura. Isto torna o modelo fisicamente similar à aeronave Bombardier Learjet 25.
148

O ruído aeronáutico como fator de perda de valor dos imóveis residenciais: o caso do aeroporto internacional de São Paulo.

Rogéria de Arantes Gomes Eller 00 December 2000 (has links)
A preocupação com condições adequadas de manejo de questões ambientais está presente em diversos setores da atividade econômica. O caráter multidisciplinar associado aos problemas ambientais propõe desafios a diversas áreas do conhecimento. As características de bem público associada aos recursos naturais dificultam sobremaneira a tarefa de mensurar economicamente este tipo de bem. Todavia, existem casos em que dados do próprio mercado oferecem condições para tal avaliação. É o caso das perdas de valor de imóveis situados em áreas de ruído aeronáutico. Essas perdas vem sendo estudadas nas áreas de entorno de diversos aeroportos do mundo desde a década de 60 e, atualmente, os instrumentos econômicos, sob a forma de taxas ou tarifas, têm sido largamente utilizados com o objetivo de incentivar as companhias aéreas a utilizarem aeronaves mais silenciosas, bem como em medidas de mitigação de impacto. No caso brasileiro, em que pese o volume de tráfego aéreo em alguns aeroportos ser igual ou até mesmo superior ao de outros aeroportos do mundo, ainda não é aplicada nenhuma tarifa de ruído. Esta questão, agravada significativamente pela observada falta de integração entre os Planos de Zoneamento de Ruído e os Planos de Zoneamento Municipais, impõe às populações que residem em área de ruído uma piora na qualidade de vida, que se torna evidente quando se verifica a perda de valor dos imóveis que estão situados nessas áreas. Utilizando conceitos de teoria econômica neoclássica, este trabalho apresenta as razões pelas quais esses prejuízos, que não são assimilados pelo mercado de transporte aéreo, precisam ser considerados com vistas à sua internalização pelo sistema de custos. Os proprietários daqueles imóveis podem ser compensados por suas perdas por meio da criação de um fundo apropriado a ser utilizado para ressarcir as perdas causadas pelo ruído aeronáutico, alem de desencorajar a operação de aeronaves mais ruidosas. Este trabalho apresenta pesquisa realizada junto às imobiliárias da cidade de Guarulhos, a qual aponta perdas no valor de mercado dos imóveis residenciais situados na área de ruído gerado pelas aeronaves operando no Aeroporto Interancional de São Paulo/Guarulhos (AISP). A já prevista construção de mais uma pista aumentará a área sob ruído, agravando os problemas de qualidade de vida da população atingida. Os resultados desta pesquisa são considerados consistentes, uma vez que confirmam os dados obtidos por meio de levantamento bibliográfico e podem, assim, ser utilizados como subsídios para a elaboração de uma taxa de ruído a ser aplicada naquele aeroporto.
149

Otimização de trajetória de decolagem com recolhimento de dispositivos hipersustentadores visando ruído mínimo

Pedro Alberto Godinho Ciloni 23 September 2011 (has links)
Atualmente durante a certificação de ruído de decolagem Part36 não é permitido se alterar a configuração aerodinâmica da aeronave, ou seja, com exceção do trem de pouso que deve ser recolhido, a posição dos dispositivos hipersustentadores deve permanecer constante durante toda a decolagem. Com isso, o desempenho da aeronave fica prejudicado, de forma que tanto a altitude final da aeronave quanto a redução de tração poderiam ser maiores caso ocorresse recolhimento de dispositivos hipersustentadores durante a subida, melhorando a eficiência aerodinâmica. O objetivo deste trabalho é estudar as possíveis melhorias em ruído aeronáutico de sobrevôo que possam advir do recolhimento de dispositivos hipersustentadores durante o procedimento de certificação de ruído. O estudo é feito através de otimização de trajetória e os resultados são comparados a uma trajetória de referência para quantificar a diminuição de ruído obtida. Os resultados indicam que um ganho significativo do ponto de vista de ruído pode ser obtido somente com esta mudança de procedimento, sem precisar alterar a aeronave propriamente dita.
150

Percepção do ruído hospitalar em funcionários de uma maternidade do município de São Bernardo do Campo / Employees perception of hospital noise in a maternity hospital in São Bernardo do Campo

Ferreira, Aidilma Silva 31 July 2013 (has links)
Made available in DSpace on 2016-04-27T18:12:01Z (GMT). No. of bitstreams: 1 Aidilma Silva Ferreira.pdf: 1574476 bytes, checksum: 6b240b6332f8c9109f21e4896d438d70 (MD5) Previous issue date: 2013-07-31 / Noise is an important public health problem. Hospitals, that should provide adequate conditions for acoustic comfort to its patients and employees, are not considered quiet environments, which can bring harm to their health. Objective. To verify the newborn assistance health professionals exposure to occupational noise and to investigate their auditory and non-auditory complaints. Method. The sample consisted of 34 nursing technicians and 32 nursing assistants, all female. The age ranged from 24 to 56 years, with a mean of 37.4. The study of the noise perception was performed using a questionnaire. Sound levels were measured by noise dosimetries on employees during their working hours in day and night shifts. Two Wed007 type 2 dosimeters of the 01dB trademark were used. Statistical analysis was performed using chi-square test to assess the relations between the variables. Results. Most professionals considered the environment to be noisy (98.4%) and believed they, somehow, contributed to ambient noise. The main noise sources reported were equipment and monitoring alarms and people talking. The discomfort, stress, fatigue and irritability were complaints that affected the professionals in a greater degree because of the sense of ambient noise. Statistically significant associations (p <0.05) with stress, fatigue and discomfort in individuals who had the perception that the environment was noisy were found. Professionals who felt more stressed because of the environmental noise perception believed that the noise interfered with their work efficiency (p = 0.002) and thinking (p = 0.010), and reported to be very or extremely annoyed by noise (p = 0.000), bad mood (p = 0.000) and irritability (p = 0.000), being harder to understand others speech (p = 0.000). The most common effects were headache and sensitivity to loud noise. LAeq levels ranged from 70.3 dB (A) to 82.5 dB (A). The minimum levels were in the range of 42.3 dB (A) and 55 dB (A). The maximum levels ranged from 81.3 dB (A) to 94.2 dB (A). Conclusions. Sound levels were higher than those recommended by the acoustic comfort standards. Important statistical associations between the noisy environment and the professionals health complaints were found. The noise can affect oral communication aspects and workers task performance / O ruído representa um importante problema de saúde pública. Os hospitais, que deveriam fornecer adequadas condições de conforto acústico aos seus pacientes e funcionários, não são considerados ambientes silenciosos, o que pode trazer prejuízo à saúde destes. Objetivo. Verificar a exposição a ruído ocupacional da equipe de profissionais de saúde que atua em setores de assistência a recém-nascido e investigar suas queixas auditivas e não auditivas. Método. A amostra foi composta por 34 técnicas de enfermagem e 32 auxiliares de enfermagem, todas do sexo feminino. A idade variou de 24 a 56 anos, sendo a média igual a 37,4. O estudo da percepção do ruído foi realizado por meio da aplicação de um questionário. Os níveis sonoros foram medidos por meio de dosimetrias de ruído nos funcionários durante a jornada de trabalho, nos turnos diurno e noturno. Foram utilizados dois dosímetros do tipo 2, modelo Wed007, marca 01dB. A análise estatística foi realizada por meio de teste qui-quadrado, para verificar as associações entre as variáveis de estudo. Resultados. A maioria dos profissionais considerou o ambiente ruidoso (98,4%) e acredita que contribui com o barulho. As principais fontes de ruído relatadas foram os equipamentos e alarmes de monitoramento e as pessoas conversando. O incômodo, o estresse, o cansaço e a irritabilidade foram as queixas que afetaram os profissionais em maior grau devido à sensação do ruído ambiente, sendo encontradas associações estatisticamente significantes (p<0,05) com o estresse, o incômodo e o cansaço em indivíduos que tinham a percepção de que o ambiente é barulhento. Os profissionais que se sentiam mais estressados pela percepção do ruído do ambiente acreditavam que o ruído atrapalhava sua eficiência no trabalho (p=0,002) e o raciocínio (p=0,010), bem como sentiam que o ruído incomodava bastante ou extremamente (p=0,000), causava mau-humor (p=0,000) e irritabilidade (p=0,000), atrapalhando entender a fala dos outros (p=0,000). Os sintomas mais relatados foram cefaleia e incômodo a sons fortes. Os valores de LAeq variaram de 70,3 dB(A) a 82,5 dB(A). Os níveis mínimos se encontravam na faixa entre 42,3 dB(A) e 55 dB(A). Os níveis máximos encontrados variaram de 81,3 dB(A) a 94,2dB(A). Conclusões. Os níveis sonoros encontrados estavam acima dos recomendados pelas normas de conforto acústico. Foram encontradas importantes associações estatísticas entre o ambiente barulhento e queixas de saúde dos profissionais. O ruído pode prejudicar aspectos relacionados à comunicação oral e afetar na execução das atividades destes profissionais

Page generated in 0.0345 seconds