• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 7
  • 3
  • 2
  • Tagged with
  • 31
  • 11
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Pathogen Reduction on Selected Vegetables Using Hydrogen Peroxide

Atuobi Ampadu, Christiana 28 June 2007 (has links)
No description available.
12

ON DATA UTILITY IN PRIVATE DATA PUBLISHING

Zhang, Yihua 04 May 2010 (has links)
No description available.
13

Frequent Itemset Hiding Algorithm Using Frequent Pattern Tree Approach

Alnatsheh, Rami H. 01 January 2012 (has links)
A problem that has been the focus of much recent research in privacy preserving data-mining is the frequent itemset hiding (FIH) problem. Identifying itemsets that appear together frequently in customer transactions is a common task in association rule mining. Organizations that share data with business partners may consider some of the frequent itemsets sensitive and aim to hide such sensitive itemsets by removing items from certain transactions. Since such modifications adversely affect the utility of the database for data mining applications, the goal is to remove as few items as possible. Since the frequent itemset hiding problem is NP-hard and practical instances of this problem are too large to be solved optimally, there is a need for heuristic methods that provide good solutions. This dissertation developed a new method called Min_Items_Removed, using the Frequent Pattern Tree (FP-Tree) that outperforms extant methods for the FIH problem. The FP-Tree enables the compression of large databases into significantly smaller data structures. As a result of this compression, a search may be performed with increased speed and efficiency. To evaluate the effectiveness and performance of the Min_Items_Removed algorithm, eight experiments were conducted. The results showed that the Min_Items_Removed algorithm yields better quality solutions than extant methods in terms of minimizing the number of removed items. In addition, the results showed that the newly introduced metric (normalized number of leaves) is a very good indicator of the problem size or difficulty of the problem instance that is independent of the number of sensitive itemsets.
14

Retrowrite: Statically Instrumenting COTS Binaries for Fuzzing and Sanitization

Sushant Dinesh (6640856) 10 June 2019 (has links)
<div>End users of closed-source software currently cannot easily analyze the security</div><div>of programs or patch them if flaws are found. Notably, end users can include devel</div><div>opers who use third party libraries. The current state of the art for coverage-guided</div><div>binary fuzzing or binary sanitization is dynamic binary translation, which results</div><div>in prohibitive overhead. Existing static rewriting techniques cannot fully recover</div><div>symbolization information, and so have difficulty modifying binaries to track code</div><div>coverage for fuzzing or add security checks for sanitizers.</div><div>The ideal solution for adding instrumentation is a static rewriter that can intel</div><div>ligently add in the required instrumentation as if it were inserted at compile time.</div><div>This requires analysis to statically disambiguate between references and scalars, a</div><div>problem known to be undecidable in the general case. We show that recovering this</div><div>information is possible in practice for the most common class of software and li</div><div>braries: 64 bit, position independent code. Based on our observation, we design a</div><div>binary-rewriting instrumentation to support American Fuzzy Lop (AFL) and Address</div><div>Sanitizer (ASan), and show that we achieve compiler levels of performance, while re</div><div>taining precision. Binaries rewritten for coverage-guided fuzzing using RetroWrite</div><div>are identical in performance to compiler-instrumented binaries and outperforms the</div><div>default QEMU-based instrumentation by 7.5x while triggering more bugs. Our im</div><div>plementation of binary-only Address Sanitizer is 3x faster than Valgrind memcheck,</div><div>the state-of-the-art binary-only memory checker, and detects 80% more bugs in our</div><div>security evaluation.</div>
15

Qualidade sanitária de hortaliças cultivadas em um distrito sanitário de Salvador-BA e eficiência de soluções antimicrobianas sobre linhagens de escherichia coli.

Santos, Ytana Tadeu Oliveira January 2007 (has links)
p. 1-102 / Submitted by Santiago Fabio (fabio.ssantiago@hotmail.com) on 2013-04-10T18:23:59Z No. of bitstreams: 1 tese seg 01.pdf: 3278405 bytes, checksum: a1f6dce4daf8c8bf747cf356d5aa8b2e (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-04-13T19:54:42Z (GMT) No. of bitstreams: 1 tese seg 01.pdf: 3278405 bytes, checksum: a1f6dce4daf8c8bf747cf356d5aa8b2e (MD5) / Made available in DSpace on 2013-04-13T19:54:42Z (GMT). No. of bitstreams: 1 tese seg 01.pdf: 3278405 bytes, checksum: a1f6dce4daf8c8bf747cf356d5aa8b2e (MD5) Previous issue date: 2007 / O consumo de hortaliças cruas constitui um importante meio de transmissão de várias doenças infecciosas, dentre estas se destacam aquelas provocadas por bactérias patogênicas, ocasionando com freqüência surtos de Doenças Veiculadas por Alimentos (DVA). Deficiências no controle em qualquer uma das etapas da produção podem comprometer a qualidade sanitária das hortaliças. Nas hortas existentes em nosso meio observam-se práticas agrícolas inadequadas durante a produção das hortaliças, dentre estas a utilização de água contaminada, comprometendo a qualidade final dos produtos. Desta forma, torna-se necessário o controle durante todas as etapas que precedem o consumo, incluindo a lavagem e sanitização adequadas destes vegetais. O cloro é um dos principais agentes sanitizantes permitido pela legislação brasileira, porém atualmente, seu uso vem sendo contestado devido à possibilidade da formação de substâncias carcinogênicas. O objetivo deste trabalho foi avaliar a qualidade higiênico-sanitária de hortas, hortaliças e água de irrigação e a eficácia sanitizante de produtos contendo ácidos orgânicos de cadeia curta sobre linhagens de Escherichia coli inoculadas artificialmente em alface. Foram investigadas cinco hortas, 140 amostras de hortaliças distribuídas entre alface, coentro, couve e hortelã, e 45 amostras de água de irrigação. Para avaliação da qualidade sanitária das hortas foi aplicado um “checklist” e para avaliar as hortaliças e águas de irrigação foram conduzidas análises microbiológicas pertinentes. Em etapa posterior, foi investigada a eficácia sanitizante de ácidos orgânicos de cadeia curta sobre duas linhagens de Escherichia coli inoculadas separadamente em alface e em seguida submetidas aos tratamentos por 15 minutos, empregando soluções de vinagre de álcool, suco de limão, mistura suco de limão e vinagre (1:1) e mistura suco de limão,vinagre e água (1:1:1). Os resultados demonstraram que 40% das hortas apresentam condições higiênico-sanitárias totalmente insatisfatórias e as análises microbiológicas revelaram elevados índices de contaminação por coliformes termotolerantes nas hortaliças com 82% de amostras contaminadas, contagens entre < 0,3 a 1500 NMP/g, presença de E. coli em 32% das amostras e ausência de Salmonella spp. Na água de irrigação também foram encontrados índices elevados de coliformes termotolerantes, com 87% de amostras contaminadas, contagens entre < 2 a 2100 NMP/100 mL, e presença de E. coli em 56% das amostras. Um total de 69% das amostras das águas não atendeu ao padrão vigente para coliformes termotolerantes. Os resultados obtidos a partir do check-list não foram condizentes com as análises microbiológicas. Quanto aos tratamentos com as soluções antimicrobianas, verificou-se que não houve diferença estatisticamente significativa (p<0,05) entre os agentes testados, contudo, as maiores reduções decimais (RD) foram obtidas com o tratamento empregando suco de limão e vinagre sobre a cepa E. coli O157: H7, valor médio de 3,25 ciclos logarítimicos. Para a cepa E. coli-Ls o melhor tratamento foi aquele empregando o vinagre, alcançando uma RD de 1,51 ciclos log. Dos resultados apresentados conclui-se que é necessária uma maior atenção por parte das autoridades competente na produção de hortaliças, para o fornecimento de alimentos seguros à população. Quanto ao uso das soluções antimicrobianas, conclui-se que se trata de uma boa opção em substituição ao uso do cloro na sanitização de hortaliças folhosas, necessitando, entretanto de mais estudos para a sua viabilização junto às indústrias de alimentos e serviços de alimentação. / Salvador
16

Utilização de agua ozonizada e radiação ultravioleta C na sanitização de melão minimamente processado / Use of ozonated water and ultraviolet radiation C in the sanitization of fresh-cut melon

Amaral, Rivia Darla Alvares, 1985- 02 February 2010 (has links)
Orientador: Benedito Carlos Benedetti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-15T14:30:00Z (GMT). No. of bitstreams: 1 Amaral_RiviaDarlaAlvares_M.pdf: 2125836 bytes, checksum: b3ba028f24bb9878b2ec5bdd1f757773 (MD5) Previous issue date: 2010 / Resumo: O sucesso comercial dos produtos minimamente processados depende da manutenção do seu estado fresco, retardando ao máximo a perda de qualidade nutricional. Esses produtos devem ser microbiologicamente seguros e ter vida útil suficiente para tornar viável o seu consumo pelos consumidores. O método mais usado no Brasil para sanitização de frutas e hortaliças minimamente processadas é o químico, por meio de solução com hipoclorito de sódio, mas devido à produção de compostos orgânicos clorados e seu potencial carcinogênico, tem ocorrido a busca por alternativas a esse sanitizante. Duas possibilidades são os métodos físicos água ozonizada e radiação UV-C. Assim, esse trabalho teve como objetivo avaliar estes sanitizantes como possíveis substituintes ao hipoclorito de sódio e foi dividido em duas fases. Na primeira foram definidas as concentrações mais adequadas de água ozonizada e radiação UV-C, além da embalagem para serem usados na segunda fase. Nesta, comparou-se os tratamentos água ozonizada (1,6 mg L-1/1 min), radiação UV-C (11,3 kJ m-2) e hipoclorito de sódio (100 mg L-1/1 min) e água corrente. Melões amarelos previamente resfriados foram minimamente processados passando por seleção, caracterização inicial, lavagem em água corrente, drenagem, corte em fatias com retirada das sementes e cascas, sanitização, drenagem, acondicionamento e armazenagem a 5 ºC ± 2 ºC por 10 dias. Os produtos foram analisados logo após o corte, após a sanitização e aos 3, 6, 8 e 10 dias de armazenamento quanto a análises físico-químicas e microbiológicas. A concentração de água ozonizada e intensidade de radiação UV-C mais efetivas na redução microbiana de melão amarelo minimamente processado foram de 1,6 mg L-1/1 minuto e 11,3 kJ m-2, respectivamente. A maior modificação da atmosfera ocorreu nas fatias embaladas com PEBD, alcançando concentrações de 15,66% e 2,43% de O2 e CO2, respectivamente, no nono dia de armazenamento. Tanto a água ozonizada quanto a radiação UV-C foram eficientes na redução da carga microbiana do melão minimamente processado armazenado a 5 ± 2 ºC por 8 dias e podem ser substitutos do hipoclorito de sódio. Os sanitizantes avaliados não comprometeram a qualidade físico-química dos melões minimamente processados / Abstract:The commercial success of minimally processed products depends on the maintenance of fresh state, avoiding the loss of nutritional quality. These products must be microbiologically safe and an enough shelf life to make feasible its use by consumers. The method most used in Brazil to sanitize fruits and vegetables is the chemical, with a solution of sodium hypochlorite, but due the production of chlorinated organic compounds and its carcinogenic potential, has been occurring the search for alternatives methods. Two possibilities are the physical methods ozonated water and UV-C radiation. Thus, this study aimed to evaluate these sanitizers as possible substitutes for sodium hypochlorite and was divided into two phases. In the first set the concentrations of ozonated water (1,6 mg L-1 , 1,8 mg L-1 and 2,0 mg L-1), UV-C radiation (4,80 kJ m-2 and 11,3 kJ m-2) and packaging (PP, LDPE and PET) to be used in the second phase were defined. In this, it was compared the treatments ozonated water (1,6 mg L-1/1 min), UV-C radiation (11,3 kJ m-2) and sodium hypochlorite (100 mg L-1/1 min) and water. Cooled yellow melons were minimally processed through selection, initial characterization, washing in water, draining, cut into slices, sanitization, drainage (1 minute), packaging and storing at 5 ºC ± 2 ºC for 10 days. The products were analyzed immediately after cutting and at 3, 6, 8 and 10 days of storage on the physical-chemical and microbiological analysis. The concentration of ozonated water and intensity of UV-C radiation more effective in the microbial reduction of fresh-cut melon were 1,6 mg L-1 for 1 minute and 11,3 kJ m-2, respectively. Slices put in PET packages remained the gas composition similar to the atmospheric air, showing that this package is not suitable when the atmospheric modification is required. The higher atmosphere reduction was in slices packaged in LDPE, reaching concentrations of 15,66% and 2,43% of O2 and CO2, respectively, on the nine day of storage. Both UV-C radiation and ozonated water were effecitve in reducing microbial load of fresh-cut melons stored at 5 ºC ± 2 ºC for 8 days and can be substitutes for sodium hypochlorite. The sanitizers evaluated did not affect thephysical-chemical quality of fresh-cut melons / Mestrado / Tecnologia Pós-Colheita / Mestre em Engenharia Agrícola
17

Enterobacter sakazakii (Cronobacter spp.) e Bacillus cereus = quorum sensing, formação de biofilme e ação de sanitizantes / Enterobacter sakazakii (Cronobacter spp.) and Bacillus cereus : quorum sensing, biofilm formation and efficacy of sanitizers

Esper, Luciana Maria Ramires 04 June 2010 (has links)
Orientadores: Arnaldo Yoshiteru Kuaye, Marcelo Palma Sircili / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-15T20:40:16Z (GMT). No. of bitstreams: 1 Esper_LucianaMariaRamires_D.pdf: 999342 bytes, checksum: 3f9fabfdcb18d73bafce5fd0ce00935e (MD5) Previous issue date: 2010 / Resumo: A contaminação de fórmulas infantis por Enterobacter sakazakii (Cronobacter spp.) e Bacillus cereus pode ter como origem o contato do alimento com biofilmes formados em ambientes, utensílios e equipamentos empregados na sua produção ou posterior reconstituição nos locais de distribuição. A grande preocupação em relação a estas bactérias é a presença das mesmas em fórmulas infantis, produtos estes utilizados como fonte de alimentação para lactentes de forma exclusiva ou em combinação com outros alimentos. A formação de biofilmes, assim como outros mecanismos celulares como por exemplo a produção de bacteriocinas e fatores de virulência, podem ser modulados pelo processo de comunicação célula-célula ou quorum sensing - mecanismo de sinalização célula-célula mediada pelo acúmulo de uma classe ou mais de moléculas sinalizadoras produzidas pela célula e excretadas para o meio externo. Por sua vez, a quebra deste sistema, pela degradação das moléculas sinalizadoras de comunicação, denomina-se quorum quenching. Neste trabalho objetivou-se, primeiramente, a avaliação da dinâmica de formação de biofilmes mono e multi-espécies de E. sakazakii (Cronobacter spp.) e B. cereus em superfície de aço inoxidável utilizando-se como meios de cultivos fórmula Infantil (FI) e caldo Luria Bertani (LB) e a eficácia de soluções de ácido peracético e de hipoclorito de sódio na inativação desses biofilmes. Outro objetivo principal foi pesquisar a ocorrência dos sistemas quorum sensing e quorum quenching em E. sakazakii (Cronobacter spp.) e B. cereus e a possível influência das moléculas sinalizadoras na sensibilidade destas bactérias aos antimicrobianos. A formação de biofilmes ocorreu de forma mais intensa ao utilizar-se a fórmula infantil, quando comparado com o meio de cultivo LB, fato este relevante por ser a fórmula infantil o mais conhecido e importante veículo de transmissão de E. sakazakii (Cronobacter spp.). Tanto em cultivo mono-espécie quanto em cultivo misto, o nível de contagem de E. sakazakii (Cronobacter spp.) superou o de B. cereus e para ambos o maior desenvolvimento ocorreu em cultivos mono-espécie. Em todos os biofilmes de E. sakazakii (Cronobacter spp.) e B. cereus isoladamente e em cultura mista, produzidos em caldo LB e independente do tempo de formação, as contagens foram reduzidas a níveis inferiores a 1 logUFC/cm2 quando em contato com soluções de ácido peracético ([500mg/L]) e hipoclorito de sódio ([100mg/L]) por 15 minutos. No entanto, para os biofilmes produzidos em fórmula infantil ocorreram algumas situações, em que as contagens de microrganismos após o contato com as soluções de sanitizantes, foram superiores a 1 logUFC/cm2, evidenciando assim a ineficácia do procedimento de sanitização para alguns biofilmes formados a 5 dias ou mais e a necessidade da higienização das superfícies ser realizada o mais próximo do término do processamento ou reconstituição destes alimentos. Evidenciou-se a existência dos sistemas quorum sensing e quorum quenching, através dos testes de atividades biológicas das culturas, extratos e suas frações. Os testes com os biossensores revelaram-se positivos para a produção de homoserinas lactonas em cepa de E. sakazakii (Cronobacter spp.) e negativos para a espécie B. cereus. Em cultivo misto de E. sakazakii (Cronobacter spp.) e B. cereus observou-se a redução e/ou a não detecção das homoserinas lactonas fato este possivelmente associado ao fenômeno quorum quenching. A possível presença de moléculas sinalizadoras AI- 2 e AI-3 foi evidenciada, sendo confirmada a presença de moléculas sinalizadoras AI-1. A caracterização do AI-1 realizada por cromatografia gasosa acoplada à espectrometria de massa (CG-EM) revelou a capacidade da cepa de E. sakazakii (Cronobacter spp.) em produzir três compostos, N-heptanoil-HSL, N-dodecanoil- HSL e N-tetradecanoil-HSL, substâncias estas ainda não reportadas na literatura para o microrganismo em estudo. Os autoindutores sintéticos C7-HSL, C12-HSL e C14-HSL adicionados a cultura de E. sakazakii (Cronobacter spp.) e B. cereus não exerceram efeito sobre a sensibilidade aos antimicrobianos, sugerindo que estas moléculas não estariam envolvidas em mecanismos de resistência a estes antimicrobianos. Em resumo este trabalho representa um importante passo no estudo da formação de biofilmes e dos sistemas quorum sensing e quenching para as bactérias em questão, cujos conhecimentos são de grande interesse na segurança dos alimentos / Abstract: The contamination of infant formulas by Enterobacter sakazakii (Cronobacter spp.) and Bacillus cereus can occur due to contact with biofilms formed in the environment and on equipment used in their production and reconstitution. There is concern about these bacteria due to their presence in foods used as a source of nutrition for infants. Biofilm formation as a wide spectrum of important processes is reported to be regulated by quorum sensing, including, for example, antibiotic production and virulence. Cell-to-cell communication or bacterial quorum sensing is a signaling mechanism that refers to the ability of bacteria to respond to chemical molecules called autoinducers, in response to cell density. Degradation of the signaling molecule prevents it from accumulating in sufficient amounts, leading to disruption of the communication system, known as quorum quenching. The aim of this study was first to evaluate the formation of mono and multi-species biofilms of Enterobacter sakazakii (Cronobacter spp.) and B. cereus on stainless steel surfaces using infant formula (FI) and Luria Bertani (LB) broth as the culture media, and the efficacy of sodium hypochlorite and peracetic acid in inactivating these biofilms. The other objective was to investigate the involvement of Enterobacter sakazakii (Cronobacter spp.) and Bacillus cereus in quorum sensing and quorum quenching systems and the possible influence of the signaling molecules on the sensibility of these bacteria to antimicrobials. The formation of biofilms was greater when using the infant formula than the Luria Bertani broth, this fact being important since the infant formula is considered to be an important vehicle in the transmission of Enterobacter sakazakii (Cronobacter spp.) to infants. In both cases, the growth of the mono species was greater than in the multi species culture. In all the biofilms formed in the Luria Bertani broth, independent of the time of formation, the counts were reduced to less than 1 log CFU/cm2 when in contact with sodium hypochlorite ([100mg/L]) or peracetic acid ([500mg/L]). However for the biofilms produced in the infant formula, many situations occurred, with counts more than1 log CFU/cm2 in some situations after the contact with sanitizers highlighting the need for na efficient sanitization of the surfaces as soon as the processing or reconstitution of these foods has finished. The experiments with biosensors provided evidence of the occurrence of quorum sensing and quorum quenching systems using bioassays with the cultures and extracts of the microorganisms under examination. These bioassays were positive for the production of homoserine lactone by E. sakazakii (Cronobacter spp.) but negative for B.cereus. In the mixed culture a reduction and/or non-detection of the homoserine lactone was observed, a fact that could be associated with quorum quenching. A possible presence of the signaling molecules AI-2 and AI-3 was evident and the presence of AI-1 was confirmed. Gas chromatography-mass spectrometry (GC-MS) analyses allowed for a chemical identification of the production of N-heptanoyl-HSL, N-dodecanoyl- HSL and N-tetradecanoyl-HSLby the E. sakazakii (Cronobacter spp.), a fact not previously reported in the literature. The addition of synthetic signaling molecules (N-heptanoyl-HSL, N-dodecanoyl-HSL and N-tetradecanoyl-HSL) had no significant effect on the sensibility of the E. sakazakii (Cronobacter spp.) and B. cereus strains to antimicrobials. In summary this study represents an important step in biofilm's formation, quorum sensing and quorum quenching in these bacteria that are of great interest in food safety / Doutorado / Doutor em Tecnologia de Alimentos
18

Avaliação da eficiência da aplicação do ozônio na cadeia de produção do queijo minas frescal / Efficiency evaluation of ozone application in the production chain of minas frescal cheese

Cavalcante, Daniel Augusto 19 August 2018 (has links)
Orientador: Marcelo Cristianini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-19T13:21:34Z (GMT). No. of bitstreams: 1 Cavalcante_DanielAugusto_D.pdf: 1728563 bytes, checksum: 5b1a221ac77adab02aa5448549adb1b0 (MD5) Previous issue date: 2012 / Resumo: O leite, por ser um alimento nutritivo e completo, é altamente consumido em todo o mundo, tanto na sua ingestão direta como através de seus derivados. Muitas ações são colocadas em prática para garantir sua qualidade, desde cuidados com a saúde dos animais leiteiros até a utilização de tratamentos para garantir uma maior vida de prateleira dos produtos lácteos. O ozônio por estar sendo estudado, atualmente, na indústria de alimentos, e, por ser um produto utilizado nas formas líquida e gasosa foi o sanitizante utilizado para a efetivação dos experimentos. O presente estudo buscou avaliar a eficiência da aplicação do ozônio na indústria de laticínios, analisando suas características frente à: desinfecção da pele do teto das vacas antes da ordenha, inativação microbiana no leite in natura, aumento na estabilidade de queijo minas frescal e sanitização de equipamentos e ar ambiente de câmaras frigoríficas de estocagem de queijo minas frescal. Foi utilizado o sanitizante na forma líquida (água ozonizada), na concentração de 2,0mg.L-1, para os estudos de sanitização da pele do teto das vacas e para imersão do queijo minas frescal; e na forma gasosa para borbulhamento no leite e para sanitização da câmara fria, nas concentrações de 1,5 e 0,03 mg.L-1, respectivamente. Foi realizado delineamento inteiramente casualizado e os dados foram avaliados quanto à normalidade dos resíduos e homogeneidade das variâncias. Os microrganismos aeróbios mesófilos e Staphylococcus sp. na pele do teto das vacas apresentaram reduções de 2,36 e 2,03 ciclos logarítmicos, para clorexidina e 2,52 e 1,99 ciclos logarítmicos para a água ozonizada, respectivamente. Para estes tratamentos não foi verificado diferenças estatísticas significativas (P>0,05). As enterobactérias apresentaram reduções de 1,16 e 1,50 ciclos logarítmicos para a clorexidina (sanitizante utilizado para fins de comparação) e água ozonizada, sendo que estes resultados foram significativamente diferentes para P<0,05. A utilização do ozônio, na concentração de 1,5mg.L-1, no tempo de exposição de 15 minutos, apresentou reduções de 0,61; 0,97; 0,13; 1,04 e 0,48 ciclos logarítmicos, respectivamente, para os microrganismos aeróbios mesófilos, psicotróficos, enterobactérias e Staphylococcus sp.e bolores e levedura no leite in natura. Não foi observada a presença de enterobactérias, coliformes totais e termotolerantes e Staphylococcus sp., nas amostras de queijo minas frescal analisadas. As reduções decimais para as populações de aeróbios mesófilos, bactérias lácticas e bolores e leveduras em queijo minas frescal, imediatamente após a aplicação da água ozonizada na concentração de 2,0mg.L-1, durante 2 minutos foi de 1,53, 1,90 e 2,34 ciclos logaritmos, respectivamente; Observou-se uma redução de microrganismos aeróbios mesófilos e bolores e leveduras de 0,81 e 1,01 ciclos logarítmicos, respectivamente, no ar ambiente da câmara fria de estocagem de queijo minas frescal, após a aplicação do gás ozônio na concentração de 0,03 mg.L-1 / Abstract: Milk, as a complete and nutritious food, is highly consumed worldwide, both in its direct ingestion and through its derivatives. Many actions are put into practice to ensure its quality, since health care of the dairy cattle to the use of treatments to ensure a longer shelf life of dairy products. Ozone has been studied nowadays in the food industry and was used in liquid and gaseous forms as sanitizer for the experiments described here. This study tried to evaluate the effectiveness of ozone application in the dairy industry, analyzing its characteristics according to: the teat skin disinfection before milking the cows, microbial inactivation in raw milk, stability increase of minas frescal cheese, equipment, maturation and cold-storage sanitizing. The sanitizer was used in liquid form (ozonated water) at a concentration of 2.0 mg L-1 for the teat skin sanitizing studies and to immerse the minas frescal cheese; and gaseous form for bubbling milk and cold chamber sanitizing, at concentrations of 1.5 and 0.03 mg L-1, respectively. It was considered completely randomized design and the data were evaluated for normality of residuals and homogeneity of variances. The mesophilic aerobic microorganisms and Staphylococcus sp. on the teat skin had reductions of 2.36 and 2.03 logarithmic cycles, for chlorhexidine and 2.52 and 1.99 log-cycles for ozonated water, respectively. For these treatments, statistically significant differences were not observed (P> 0.05). The Enterobacteriacea had reductions of 1.16 and 1.50 logarithmic cycles for chlorhexidine and ozonated water, and these treatments showed statistically significant differences (P<0.05). The ozone sanitizer at a concentration of 1.5 mg L-1and exposure time of 15 minutes showed reductions of 0.61, 0.97, 0.13, 1.04 and 0.48 logarithmic cycles, respectively, for the mesophilic aerobic microorganisms, psychotropic, Enterobacteriaceae and Staphylococcusp., molds and yeast in the raw milk. We did not observe the presence of Enterobacteriaceae, total coliforms, thermotolerants and Staphylococcus spp. in the minas frescal cheese samples analyzed. The decimal reductions for the populations of aerobic mesophiles,lactic bacteria, yeasts and molds in the minas frescal cheese, immediately after the application of ozonated water at a concentration of 2.0 mg.L-1 for 2 minutes were 1, 53, 1.90 and 2.34 log-cycles, respectively. There was a reduction of mesophilic aerobic, yeast and mold of 0.81 and 1.01 log-cycles, respectively, in the minas frescal cheese cold storage and maturation, after application of ozone gas concentration of 0.03 mg.L-1 / Doutorado / Tecnologia de Alimentos / Doutor em Tecnologia de Alimentos
19

Avaliação de eficácia da sanitização de um sistema de purificação de água. Esterilização de artigos médicos, dissipação residual do óxido de etileno e uso da proteína verde fluorescente (GFP) como inidicador de controle do processo / Evaluation of effectiveness of the sanitization of a water purification system. Sterilization of medical devices, residual dissipation of ethylene oxide and the use of green fluorescent protein (GFP) as an indicator of process control

Fabio Nunes Dias 22 August 2007 (has links)
A água exerce papel fundamental nas diferentes fases do processo de fabricação de artigos para saúde (médico-hospitalares, farmacêuticos, e clínicos), exigindo elevado grau de pureza, que certifique a sua inocuidade. Portanto, se faz necessário maior controle dos sistemas de purificação de água e suas etapas de tratamento, onde a formação de biofilmes pode contaminar os artigos para saúde e, consequentemente, causar injúria a pacientes submetidos à aplicação dos mesmos. Embora os artigos médicos sejam esterilizados por óxido de etileno (ETO), seu processo de manufatura deve prever o mínimo acréscimo possível de contaminantes. Considerando que a água purificada e a esterilização dos artigos para saúde são fatores determinantes para o sucesso de sua aplicação, este trabalho foi dividido em duas partes distintas. A primeira parte aborda o controle das etapas de purificação da água, que é destinada à lavagem de componentes termoplásticos, que são utilizados na fabricação de artigos para saúde. Os níveis máximos de carga microbiana (expressos em ciclos de log10 UFC/100mL) encontrados ao longo do sistema de purificação de água foram: 3,48 log10 na água de entrada; 3,57 log10 nos filtros multimeios; 3,75 log10 nos abrandadores; 4,97 log10 no filtro de carvão ativado; 2,53 log10 na osmose reversa; 2,70 log10 no tanque de estocagem e distribuição; 2,56 log10 na lâmpada ultravioleta; 2,53 log10 nos filtros 0,05 &#181;m; 1,98 log10 nos pontos de uso. Flavimonas oryzihabitans e Micrococcus luteus foram as bactérias Gram-negativa e Grampositiva, respectivamente, isoladas e identificadas com maior freqüência na água, em diferentes estágios do sistema, inclusive após a passagem dessa através das membranas de osmose reversa. A segunda parte do estudo teve como objetivo determinar o tempo de aeração necessário para que os oxigenadores de sangue e conjuntos de tubos de PVC, após esterilização por ETO, permaneçam em aeração, para dissipação dos resíduos de ETO. Avaliou-se também a potencialidade da proteína verde fluorescente (GFP) como biossensor no processo de esterilização. O processo de esterilização destes artigos médicos foi monitorado com indicadores biológicos Bacillus atrophaeus, proteína verde fluorescente (GFP) e controles de temperatura, pressão e umidade em ciclos de 2 h (ciclo curto), 4 h (meio ciclo) e 8 h (ciclo longo). As curvas de dissipação, determinadas por cromatografia gasosa, confirmaram níveis residuais menores que 25 ppm para ETO e etileno cloridrina (EC); e inferiores a 250 ppm para etileno glicol (EG), ao final do processo de esterilização para os oxigenadores; e, após 221 horas de aeração, para os conjuntos de tubos de PVC. Nos ciclos de esterilização, as reduções na intensidade de fluorescência da GFP ocorreram em função do tempo de exposição ao ETO; enquanto germinação de esporos e/ou crescimento de B. atrophaeus não foi observado. / The water exerts important paper in different phases of critical items manufacture in the health care units, pharmaceutical industries, hospitals and clinics, becoming necessary a rigorous control of the water purification systems, storage and distribution, in order to prevent biofilms formation and cross-contamination between devices and patients, who are submitted to critical articles and parenteral solution application. The sterilization of critical devices by ethylene oxide (ETO) should predict minimum addition of possible contaminants and residues. Considering that the purified water and the sterilization are crucial factors for medical devices, this work was divided in two parts. The first part evaluated continuously the stages of the system for the purification of the water, which purity level is critical and determines the quality of the washing of thermoplastic components used in the manufacture of critical items. The maximum levels of heterotrophic load (log10 UFC/100mL) found throughout the water purification system were: 3.48 log10 in the water inlet; 3.57 log10 in the multimedium filters; 3.75 log10 in the softeners; 4.97 log10 in the activated carbon filter; 2.53 log10 in the reverse osmosis; 2.70 log10 in the tank of storage and distribution; 2.56 log10 in the UV lamp; 2.53 log10 in the 0.05&#181;m filters; 1.98 log10 in the consumption points. Flavimonas oryzihabitans and Micrococcus luteus were the main Gram-negative and Grampositive bacteria, respectively found in the purified water after reverse osmosis. The second part of this study had as objective the determination of the needed aeration time for blood oxygenators and sets of PVC tubing must be kept in aeration room for dissipation of ETO residues; and also evaluated the possibility of GFP as biosensor. ETO is used as in a mixture (10% ETO and 90% CO2). Residual levels of ETO and its derivatives, ethylene chloridrin (ECH) and ethylene glycol (EG), which remain in these devices, must be controlled to prevent serious injuries to the patients. The sterilization process of the oxygenators and sets of PVC tubing was monitored with Bacillus atrophaeus and fluorescent green protein (GFP). The temperature, pressure and humidity were controlled in the sterilization cycles of 2 h (short cycle), 4 h (half cycle) and 8 h (long cycle). The dissipation curves of the residues were determined by gaseous chromatography and the residual concentrations were lower than 25 ppm of ETO and ECH and lower than 250 ppm of EG immediately after the sterilization processes for oxygenators and after 221 hours of aeration for the sets of PVC tubing. Reductions in the fluorescence intensity of GFP were observed as a function of the exposition time to the ETO. No growth of B. atrophaeus spores was observed after cycles.
20

Avaliação de eficácia da sanitização de um sistema de purificação de água. Esterilização de artigos médicos, dissipação residual do óxido de etileno e uso da proteína verde fluorescente (GFP) como inidicador de controle do processo / Evaluation of effectiveness of the sanitization of a water purification system. Sterilization of medical devices, residual dissipation of ethylene oxide and the use of green fluorescent protein (GFP) as an indicator of process control

Dias, Fabio Nunes 22 August 2007 (has links)
A água exerce papel fundamental nas diferentes fases do processo de fabricação de artigos para saúde (médico-hospitalares, farmacêuticos, e clínicos), exigindo elevado grau de pureza, que certifique a sua inocuidade. Portanto, se faz necessário maior controle dos sistemas de purificação de água e suas etapas de tratamento, onde a formação de biofilmes pode contaminar os artigos para saúde e, consequentemente, causar injúria a pacientes submetidos à aplicação dos mesmos. Embora os artigos médicos sejam esterilizados por óxido de etileno (ETO), seu processo de manufatura deve prever o mínimo acréscimo possível de contaminantes. Considerando que a água purificada e a esterilização dos artigos para saúde são fatores determinantes para o sucesso de sua aplicação, este trabalho foi dividido em duas partes distintas. A primeira parte aborda o controle das etapas de purificação da água, que é destinada à lavagem de componentes termoplásticos, que são utilizados na fabricação de artigos para saúde. Os níveis máximos de carga microbiana (expressos em ciclos de log10 UFC/100mL) encontrados ao longo do sistema de purificação de água foram: 3,48 log10 na água de entrada; 3,57 log10 nos filtros multimeios; 3,75 log10 nos abrandadores; 4,97 log10 no filtro de carvão ativado; 2,53 log10 na osmose reversa; 2,70 log10 no tanque de estocagem e distribuição; 2,56 log10 na lâmpada ultravioleta; 2,53 log10 nos filtros 0,05 &#181;m; 1,98 log10 nos pontos de uso. Flavimonas oryzihabitans e Micrococcus luteus foram as bactérias Gram-negativa e Grampositiva, respectivamente, isoladas e identificadas com maior freqüência na água, em diferentes estágios do sistema, inclusive após a passagem dessa através das membranas de osmose reversa. A segunda parte do estudo teve como objetivo determinar o tempo de aeração necessário para que os oxigenadores de sangue e conjuntos de tubos de PVC, após esterilização por ETO, permaneçam em aeração, para dissipação dos resíduos de ETO. Avaliou-se também a potencialidade da proteína verde fluorescente (GFP) como biossensor no processo de esterilização. O processo de esterilização destes artigos médicos foi monitorado com indicadores biológicos Bacillus atrophaeus, proteína verde fluorescente (GFP) e controles de temperatura, pressão e umidade em ciclos de 2 h (ciclo curto), 4 h (meio ciclo) e 8 h (ciclo longo). As curvas de dissipação, determinadas por cromatografia gasosa, confirmaram níveis residuais menores que 25 ppm para ETO e etileno cloridrina (EC); e inferiores a 250 ppm para etileno glicol (EG), ao final do processo de esterilização para os oxigenadores; e, após 221 horas de aeração, para os conjuntos de tubos de PVC. Nos ciclos de esterilização, as reduções na intensidade de fluorescência da GFP ocorreram em função do tempo de exposição ao ETO; enquanto germinação de esporos e/ou crescimento de B. atrophaeus não foi observado. / The water exerts important paper in different phases of critical items manufacture in the health care units, pharmaceutical industries, hospitals and clinics, becoming necessary a rigorous control of the water purification systems, storage and distribution, in order to prevent biofilms formation and cross-contamination between devices and patients, who are submitted to critical articles and parenteral solution application. The sterilization of critical devices by ethylene oxide (ETO) should predict minimum addition of possible contaminants and residues. Considering that the purified water and the sterilization are crucial factors for medical devices, this work was divided in two parts. The first part evaluated continuously the stages of the system for the purification of the water, which purity level is critical and determines the quality of the washing of thermoplastic components used in the manufacture of critical items. The maximum levels of heterotrophic load (log10 UFC/100mL) found throughout the water purification system were: 3.48 log10 in the water inlet; 3.57 log10 in the multimedium filters; 3.75 log10 in the softeners; 4.97 log10 in the activated carbon filter; 2.53 log10 in the reverse osmosis; 2.70 log10 in the tank of storage and distribution; 2.56 log10 in the UV lamp; 2.53 log10 in the 0.05&#181;m filters; 1.98 log10 in the consumption points. Flavimonas oryzihabitans and Micrococcus luteus were the main Gram-negative and Grampositive bacteria, respectively found in the purified water after reverse osmosis. The second part of this study had as objective the determination of the needed aeration time for blood oxygenators and sets of PVC tubing must be kept in aeration room for dissipation of ETO residues; and also evaluated the possibility of GFP as biosensor. ETO is used as in a mixture (10% ETO and 90% CO2). Residual levels of ETO and its derivatives, ethylene chloridrin (ECH) and ethylene glycol (EG), which remain in these devices, must be controlled to prevent serious injuries to the patients. The sterilization process of the oxygenators and sets of PVC tubing was monitored with Bacillus atrophaeus and fluorescent green protein (GFP). The temperature, pressure and humidity were controlled in the sterilization cycles of 2 h (short cycle), 4 h (half cycle) and 8 h (long cycle). The dissipation curves of the residues were determined by gaseous chromatography and the residual concentrations were lower than 25 ppm of ETO and ECH and lower than 250 ppm of EG immediately after the sterilization processes for oxygenators and after 221 hours of aeration for the sets of PVC tubing. Reductions in the fluorescence intensity of GFP were observed as a function of the exposition time to the ETO. No growth of B. atrophaeus spores was observed after cycles.

Page generated in 0.0972 seconds