• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 12
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 30
  • 30
  • 12
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aprimoramento do método de estimação de gordura corporal em um Scanner 3D antropométrico / Improvement of a body fat mass estimation method through a 3D anthropometric Scanner

Lacerda, Michel Alves 03 August 2015 (has links)
Este trabalho apresenta o estudo realizado no aprimoramento de um método de estimação de gordura corpórea por meio de um Scanner antropométrico ALLBODYSCAN 3D® (São Carlos, SP, 2012) que constrói imagens 3D do corpo humano. Procedimentos computacionais de análise de modelo corporal gerado pelo scanner, têm sido desenvolvidos na USP. Este estudo considerou medições em voluntários de vários grupos de interesse, de forma que a estimação de gordura pudesse ter abrangência satisfatória e com poucos fatores de erro, aprimorando a técnica. A pesquisa envolveu aspectos de gênero, etnia e idade de cada um dos voluntários. Os resultados foram comparados com estimações obtidas por Bioimpedância e por Adipometria e apresentaram alta correlação. O Scanner antropométrico apresentou suas medições com certas vantagens, comparado a outras técnicas, principalmente em relação à simplificação de procedimentos com o paciente para se obter medições confiáveis. / The present paper shows the research done in the improvement of a method to estimate the body fat mass using an anthropometric Scanner AllBodyScan3D® (São Carlos, SP, 2012) that builds up 3D images from the human body. Computational procedures for body composition analysis have been developed at USP. The present study has considered measurements in different groups of volunteers, in a way that it can lead to satisfactory coverage, with relatively low error, improving the approach. The research has considered gender, ethnics and age of each volunteer. The results were compared to estimations from Bioimpedance and Adipometry and they presented high correlation. The anthropometric Scanner has shown some advantages in comparison to other techniques, mainly due to its simplified procedures imposed on patients for obtaining reliable measures.
2

Dispositivo de varredura laser 3D terrestre e suas aplicações na engenharia, com ênfase em túneis. / Terrestrial laser scanner and its engineering applications, with emphasis in tunnels.

Gonçales, Rodrigo 18 April 2007 (has links)
Novas tecnologias estão sendo desenvolvidas constantemente para coletar informações de superfícies ou de sólidos para diversas finalidades. Alguns métodos clássicos, como a Topografia e a Fotogrametria terrestre, com o passar dos anos, tiveram uma grande evolução. Na Fotogrametria terrestre todo o processo está sendo feito em meio digital. Na topografia, as estações totais automatizaram a medição de ângulos e distâncias. Essa evolução tecnológica fez com que os levantamentos se tornassem cada vez mais rápidos e precisos, aumentando a produtividade. O mais recente nessa evolução é o levantamento através do sistema de varredura a laser (Laser Scanner) 3D. São muitas as aplicações dessa tecnologia, dentre as quais pode-se citar: túneis, levantamento do como construído (as-built), mineração (principalmente subterrânea), arqueologia, levantamento de monumentos para restauração, refinarias e instalações industriais e outras, caracterizadas pela grande complexidade dos elementos envolvidos. A presente dissertação apresenta os conceitos envolvidos em todos os processos, desde a coleta de dados até o produto final. Desenvolve uma metodologia de uso que possa ser útil em diversas áreas, mostra uma aplicação completa na área de túneis, complementada por uma visão geral da área de plantas industriais e procura apresentar testes para quantificar a precisão que se obtém por essa tecnologia. / New technologies are constantly being developed in order to collect information of surfaces or solids for diverse purposes. Some classic methods such as topography and terrestrial photogrammetry have had a great evolution in the past. For example, all the processes of the terrestrial photogrammetry are made in digital way and the Total Stations have automated the measurements of angles and distances. This technical evolution made the surveying faster and accurate, increasing the productivity. However this evolution does not stop for there; in other words, the last technology in the area of topography is the surveying with the system known as Laser Scanner 3D. The Laser Scanner technology 3D has a lot of applications such as: tunnel, as-built, mining (mainly in the underground); archaeology (for restore monuments), refineries, industrial installations, etc., characterized by the great complexity of the involved elements. This work presents concepts involved in all the processes, since from data collection to the final product. It develops a methodology of use that can be applied in several areas, with emphasis in tunnels surveying area and presents some tests to quantization the accuracy.
3

Dispositivo de varredura laser 3D terrestre e suas aplicações na engenharia, com ênfase em túneis. / Terrestrial laser scanner and its engineering applications, with emphasis in tunnels.

Rodrigo Gonçales 18 April 2007 (has links)
Novas tecnologias estão sendo desenvolvidas constantemente para coletar informações de superfícies ou de sólidos para diversas finalidades. Alguns métodos clássicos, como a Topografia e a Fotogrametria terrestre, com o passar dos anos, tiveram uma grande evolução. Na Fotogrametria terrestre todo o processo está sendo feito em meio digital. Na topografia, as estações totais automatizaram a medição de ângulos e distâncias. Essa evolução tecnológica fez com que os levantamentos se tornassem cada vez mais rápidos e precisos, aumentando a produtividade. O mais recente nessa evolução é o levantamento através do sistema de varredura a laser (Laser Scanner) 3D. São muitas as aplicações dessa tecnologia, dentre as quais pode-se citar: túneis, levantamento do como construído (as-built), mineração (principalmente subterrânea), arqueologia, levantamento de monumentos para restauração, refinarias e instalações industriais e outras, caracterizadas pela grande complexidade dos elementos envolvidos. A presente dissertação apresenta os conceitos envolvidos em todos os processos, desde a coleta de dados até o produto final. Desenvolve uma metodologia de uso que possa ser útil em diversas áreas, mostra uma aplicação completa na área de túneis, complementada por uma visão geral da área de plantas industriais e procura apresentar testes para quantificar a precisão que se obtém por essa tecnologia. / New technologies are constantly being developed in order to collect information of surfaces or solids for diverse purposes. Some classic methods such as topography and terrestrial photogrammetry have had a great evolution in the past. For example, all the processes of the terrestrial photogrammetry are made in digital way and the Total Stations have automated the measurements of angles and distances. This technical evolution made the surveying faster and accurate, increasing the productivity. However this evolution does not stop for there; in other words, the last technology in the area of topography is the surveying with the system known as Laser Scanner 3D. The Laser Scanner technology 3D has a lot of applications such as: tunnel, as-built, mining (mainly in the underground); archaeology (for restore monuments), refineries, industrial installations, etc., characterized by the great complexity of the involved elements. This work presents concepts involved in all the processes, since from data collection to the final product. It develops a methodology of use that can be applied in several areas, with emphasis in tunnels surveying area and presents some tests to quantization the accuracy.
4

Aprimoramento do método de estimação de gordura corporal em um Scanner 3D antropométrico / Improvement of a body fat mass estimation method through a 3D anthropometric Scanner

Michel Alves Lacerda 03 August 2015 (has links)
Este trabalho apresenta o estudo realizado no aprimoramento de um método de estimação de gordura corpórea por meio de um Scanner antropométrico ALLBODYSCAN 3D® (São Carlos, SP, 2012) que constrói imagens 3D do corpo humano. Procedimentos computacionais de análise de modelo corporal gerado pelo scanner, têm sido desenvolvidos na USP. Este estudo considerou medições em voluntários de vários grupos de interesse, de forma que a estimação de gordura pudesse ter abrangência satisfatória e com poucos fatores de erro, aprimorando a técnica. A pesquisa envolveu aspectos de gênero, etnia e idade de cada um dos voluntários. Os resultados foram comparados com estimações obtidas por Bioimpedância e por Adipometria e apresentaram alta correlação. O Scanner antropométrico apresentou suas medições com certas vantagens, comparado a outras técnicas, principalmente em relação à simplificação de procedimentos com o paciente para se obter medições confiáveis. / The present paper shows the research done in the improvement of a method to estimate the body fat mass using an anthropometric Scanner AllBodyScan3D® (São Carlos, SP, 2012) that builds up 3D images from the human body. Computational procedures for body composition analysis have been developed at USP. The present study has considered measurements in different groups of volunteers, in a way that it can lead to satisfactory coverage, with relatively low error, improving the approach. The research has considered gender, ethnics and age of each volunteer. The results were compared to estimations from Bioimpedance and Adipometry and they presented high correlation. The anthropometric Scanner has shown some advantages in comparison to other techniques, mainly due to its simplified procedures imposed on patients for obtaining reliable measures.
5

Plant canopy modeling from Terrestrial LiDAR System distance and intensity data / Modélisation géométrique de la canopée des plantes à partir des données d'intensité et de distance fournies par un Système LiDAR Terrestre

Balduzzi, Mathilde 24 November 2014 (has links)
Le défi de cette thèse est de reconstruire la géométrie 3D de la végétation à partir des données de distance et d'intensité fournies par un scanner de type LiDAR. Une méthode de « shape-from-shading » par propagation est développée pour être combinée avec une méthode de fusion de données type filtre de Kalman pour la reconstruction optimale des surfaces foliaires.-Introduction-L'analyse des données LiDAR nous permet de dire que la qualité du nuage de point est variable en fonction de la configuration de la mesure : lorsque le LiDAR mesure le bord d'une surface ou une surface fortement inclinée, il intègre dans sa mesure une partie de l'arrière plan. Ces configurations de mesures produisent des points aberrants. On retrouve souvent ce type de configuration pour la mesure de feuillages puisque ces derniers ont des géométries fragmentées et variables. Les scans sont en général de mauvaise qualité et la quantité d'objets présents dans le scan rend la suppression manuelle des points aberrants fastidieuse. L'objectif de cette thèse est de développer une méthodologie permettant d'intégrer les données d'intensité LiDAR aux distances pour corriger automatiquement ces points aberrants. -Shape-From-Shading-Le principe du Shape-From-Shading (SFS) est de retrouver les valeurs de distance à partir des intensités d'un objet pris en photo. La caméra (capteur LiDAR) et la source de lumière (laser LiDAR) ont la même direction et sont placés à l'infini relativement à la surface, ce qui rend l'effet de la distance sur l'intensité négligeable et l'hypothèse d'une caméra orthographique valide. En outre, la relation entre angle d'incidence lumière/surface et intensité est connue. Par la nature des données LiDAR, nous pourrons choisir la meilleure donnée entre distance et intensité à utiliser pour la reconstruction des surfaces foliaires. Nous mettons en place un algorithme de SFS par propagation le long des régions iso-intenses pour pouvoir intégrer la correction de la distance grâce à l'intensité via un filtre de type Kalman. -Design mathématique de la méthode-Les morceaux de surface correspondant aux régions iso-intenses sont des morceaux de surfaces dites d'égales pentes, ou de tas de sable. Nous allons utiliser ce type de surface pour reconstruire la géométrie 3D correspondant aux images d'intensité.Nous démontrons qu'à partir de la connaissance de la 3D d'un bord d'une région iso-intense, nous pouvons retrouver des surfaces paramétriques correspondant à la région iso-intense qui correspondent aux surfaces de tas de sable. L'initialisation de la région iso-intense initiale (graine de propagation) se fait grâce aux données de distance LiDAR. Les lignes de plus grandes pentes de ces surfaces sont générées. Par propagation de ces lignes (et donc génération du morceau de la surface en tas de sable), nous déterminons l'autre bord de la région iso-intense. Puis, par itération, nous propagerons la reconstruction de la surface. -Filtre de Kalman-Nous pouvons considérer cette propagation des lignes de plus grande pente comme étant le calcul d'une trajectoire sur la surface à reconstruire. Dans le cadre de notre étude, la donnée de distance est toujours disponible (données du scanner 3D). Ainsi il est possible de choisir, lors de la propagation, quelle donnée (distance ou intensité) utiliser pour la reconstruction. Ceci peut être fait notamment grâce à une fusion de type Kalman. -Algorithme-Pour procéder à la reconstruction par propagation, il est nécessaire d'hiérarchiser les domaines iso-intenses de l'image. Une fois que les graines de propagation sont repérées, elles sont initialisées avec l'image des distances. Enfin, pour chacun des nœuds de la hiérarchie (représentant un domaine iso-intense), la reconstruction d'un tas de sable est faite. C'est lors de cette dernière étape qu'une fusion de type Kalman peut être introduite. / The challenge of this thesis is reconstruct the 3D geometry of vegetation from distance and intensity data provided by a 3D scanner LiDAR. A method of “Shape-From-Shading” by propagation is developed to be combined with a fusion method of type “Kalman” to get an optimal reconstruction of the leaves. -Introduction-The LiDAR data analysis shows that the point cloud quality is variable. This quality depends upon the measurement set up. When the LiDAR laser beam reaches the edge of a surface (or a steeply inclined surface), it also integrate background measurement. Those set up produce outliers. This kind of set up is common for foliage measurement as foliages have in general fragmented and complex shape. LiDAR data are of bad quality and the quantity of leaves in a scan makes the correction of outliers fastidious. This thesis goal is to develop a methodology to allow us to integrate the LiDAR intensity data to the distance to make an automatic correction of those outliers. -Shape-from-shading-The Shape-from-shading principle is to reconstruct the distance values from intensities of a photographed object. The camera (LiDAR sensor) and the light source (LiDAR laser) have the same direction and are placed at infinity relatively to the surface. This makes the distance effect on intensity negligible and the hypothesis of an orthographic camera valid. In addition, the relationship between the incident angle light beam and intensity is known. Thanks to the LiDAR data analysis, we are able to choose the best data between distance and intensity in the scope of leaves reconstruction. An algorithm of propagation SFS along iso-intense regions is developed. This type of algorithm allows us to integrate a fusion method of type Kalman. -Mathematical design of the method-The patches of the surface corresponding to the iso-intense regions are patches of surfaces called the constant slope surfaces, or sand-pile surfaces. We are going to use those surfaces to rebuild the 3D geometry corresponding to the scanned surfaces. We show that from the knowledge of the 3d of an iso-intensity region, we can construct those sand-pile surfaces. The initialization of the first iso-intense regions contour (propagation seeds) is done with the 3D LiDAR data. The greatest slope lines of those surfaces are generated. Thanks to the propagation of those lines (and thus of the corresponding sand-pile surface), we build the other contour of the iso-intense region. Then, we propagate the reconstruction iteratively. -Kalman filter-We can consider this propagation as being the computation of a trajectory on the reconstructed surface. In our study framework, the distance data is always available (3D scanner data). It is thus possible to choose which data (intensity vs distance) is the best to reconstruct the object surface. This can be done with a fusion of type Kalman filter. -Algorithm-To proceed a reconstruction by propagation, it is necessary to order the iso-intensity regions. Once the propagation seeds are found, they are initialized with the distances provided by the LiDAR. For each nodes of the hierarchy (corresponding to an iso-intensity region), the sand-pile surface reconstruction is done. -Manuscript-The thesis manuscript gathers five chapters. First, we give a short description of the LiDAR technology and an overview of the traditional 3D surface reconstruction from point cloud. Then we make a state-of-art of the shape-from –shading methods. LiDAR intensity is studied in a third chapter to define the strategy of distance effect correction and to set up the incidence angle vs intensity relationship. A fourth chapter gives the principal results of this thesis. It gathers the theoretical approach of the SFS algorithm developed in this thesis. We will provide its description and results when applied to synthetic images. Finally, a last chapter introduces results of leaves reconstruction.
6

A repercussão periodontal e dentária decorrente da expansão rápida da maxila assistida cirurgicamente: estudo em modelos digitais

Fernandes, Mariana dos Santos 19 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:10Z (GMT). No. of bitstreams: 1 01-Introducao.pdf: 10577 bytes, checksum: 4d03882fe775b4b1c91190db6ba04a21 (MD5) Previous issue date: 2008-02-19 / The rapid maxillary expansion surgically assisted (RMESA) is one of the procedures of choice for the correction of cross-sectional deficiency in adult patients. This study evaluated the changes produced in upper and lower dental arches of 18 patients, being 6 male and 12 female, with mean age of 23,3 years old undergoing RMESA. For each patient were prepared 3 plaster models, that were digitalized with Scanner 3D, obtained in different phases: inicial, before the surgical procedure (T1); 03 months post-expansion (T2); 06 months post-expansion (T3). Were evaluated the cross-sectional distances of upper and lower dental arches, the dental tipping of the upper posterior teeth, the clinical crown height of upper posterior teeth and it was observed if there were correlation between the amount of dental tipping with the development of gingival recessions. For the results analysis were used the Variance Analysis, the Tukey Test and the Pearson Correlation Test, being that for the analysis of systematical error intra-examiner was used the coupled Test t and for the determination of casual error it was used the error calculus of Dahlberg. Based on the methodology used and in the results obtained, it was concluded that: 1. In relaction to the changes produced in cross-sectional sense of the upper arch, it was obtained an increase in all the variants from T2 to T3 showing effectiveness and stability of RMESA; 2. In the lower arch there were not statistically significant cross-sectional changes, with exception of the first molars; 3. In relation to the dental tipping, it was observed its increase from T1 to T2 in all the teeth, however, with statistical significance only for the second molar and first and second premolar on right side and first molar and second premolar on left side; 4. The RMESA did not caused the development of gingival recession in no one of the times; 5. There was not correlaction between the amount of dental tipping and the development of gingival recession.(AU) / A expansão rápida da maxila assistida cirurgicamente (ERMAC) é um dos procedimentos de escolha para correção da deficiência transversal em pacientes adultos. Este estudo avaliou as alterações produzidas nos arcos dentais superiores e inferiores de 18 pacientes, sendo seis do sexo masculino e 12 do sexo feminino, com média de idade de 23,3 anos submetidos à ERMAC. Para cada paciente foram preparados três modelos de gesso, que foram digitalizados por meio do Scanner 3D, obtidos em diferentes fases: inicial, antes do procedimento operatório (T1); três meses pós-expansão (T2); seis meses pós-expansão (T3). Foram avaliadas as distâncias transversais do arcos dentários superior e inferior, a inclinação dentária dos dentes posteriores superiores, a altura da coroa clínica dos dentes posteriores do arco superior e foi observado se havia correlação entre a quantidade de inclinação dentária com o desenvolvimento de recessões gengivais. Para análise dos resultados foram utilizados a análise de Variância, o Teste de Tukey e o Teste de Correlação de Pearson, sendo que para a análise do erro sistemático intra-examinador foi utilizado o teste t pareado e para determinação do erro casual utilizou-se o cálculo do erro de Dahlberg. Com base na metodologia utilizada e nos resultados obtidos, pode-se concluir que: 1. com relação as alterações produzidas no sentido transversal do arco superior, obteve-se um aumento em todas as variáveis de T1 para T2 e uma manutenção dos valores em todas as variáveis de T2 para T3 demonstrando efetividade e estabilidade do procedimento; 2. no arco inferior não houve alterações transversais estatisticamente significantes, com exceção dos primeiros molares; 3. com relação às inclinações dentárias, observou-se um aumento desta de T1 para T2 em todos os dentes, porém, com significância estatística apenas para segundo molar e primeiro e segundo pré-molar do lado direito e primeiro molar e segundo pré-molar do lado esquerdo.; 4. a ERMAC não acarretou o desenvolvimento de recessões gengivais em nenhum dos tempos; 5. não houve correlação entre a quantidade de inclinação dentária e o desenvolvimento de recessões gengivais.(AU)
7

Avaliação Comparativa dos Scanners 3D Artec MHT e Cyberware WBX para aplicações em Antropometria e Ergonomia / Comparative assessment of Artec MHT and Cyberware WBX 3D Scanners for applications in Anthropometry and Ergonomic Studies

Denise Silva Batista 29 January 2014 (has links)
A partir das dimensões dos indivíduos pode-se definir dimensionamentos adequados para os produtos e postos de trabalho, proporcionando segurança e conforto aos usuários. Com o avanço da tecnologia de digitalização de imagens (escaneamento) 3D, é possível tirar algumas medidas de maneira mais rápida e com a redução da presença do entrevistado durante o processo. No entanto, faltam estudos que avaliem estas tecnologias no Brasil, sendo necessária a realização de uma comparação das tecnologias e das respectivas precisões para que seu uso em pesquisas. Com o objetivo de oferecer métodos comparativos para escolha dos marcadores e equipamentos a serem utilizados em uma pesquisa antropométrica tridimensional da população brasileira, no presente estudo estão comparadas duas tecnologias de escaneamento: o sistema a laser WBX da empresa norte americana Cyberware e o sistema MHT da empresa russa Artec Group. O método para avaliação da precisão dimensional dos dados advindos desses equipamentos de digitalização de imagens 3D teve cinco etapas: Estudo dos processos de escaneamento; Escaneamento dos marcadores de pontos anatômicos; Escaneamento utilizando um corpo de prova cilíndrico; Escaneamento de um manequim; Escaneamento de um voluntário que teve seus pontos anatômicos marcados para a retirada de medidas. Foi feita uma comparação entre as medidas retiradas manualmente, por meio de antropômetro e virtualmente, com o auxílio do software de modelagem tridimensional Rhinoceros. Em relação aos resultados obtidos na avaliação do manequim e do voluntário, concluiu-se que a magnitude do erro absoluto é semelhante para ambos os scanners, e permanece constante independentemente das dimensões sob análise. As principais diferenças são em relação às funcionalidades dos equipamentos. / Only from the dimensions of individuals it is possible to define appropriate sizing for products and workplaces, providing security and comfort to users. With the evolution of 3D digital imaging technology (3D scanning), it is possible to take some measurements faster and reduce the need of the interviewee during the process. However, there are few studies that evaluate these technologies in Brazil. It is necessary to compare these equipments in order to know their precision so they can be used in researches. In order to choose anatomical markers and equipments, this study compares two different equipments: Cyberware WBX laser scanner and Artec Group MHT white light scanner. The method for assessing the dimensional accuracy of the data obtained from those scanning 3D imaging equipment had five steps: Study of the scanning processes; Scanning using a cylindrical object; Scanning a mannequin; Scanning a volunteer who had his anatomical points marked for taking measurements. The comparison was made between the measurements taken manually with an anthropometer and virtually using the 3D modeling software Rhinoceros. Based on results obtained in the evaluation of the mannequin and volunteer, it was concluded that the absolute error is similar for both scanners and remains constant regardless of the size under consideration. The main differences are the features of each equipment.
8

Projeto e construção de um scanner tridimensional baseado no método de triangulação a laser utilizando softwares livres /

Moreira, Sandro Silva January 2016 (has links)
Orientador: Ruis Camargo Tokimatsu / Resumo: A modelagem tridimensional muito já contribuiu com a indústria do entretenimento e agora tem sido amplamente utilizada na manufatura e criação de novos produtos. A possibilidade de se ter um modelo de um produto a um preço menor e com uma maior rapidez tem feito essa técnica ser cada vez mais aceita em todas as áreas da engenharia. Quando já se tem um modelo real e deseja-se realizar alguma modificação, simulação ou mesmo replicar o produto, a engenharia reversa muito pode contribuir, pois permite a obtenção do modelo tridimensional a partir do objeto real. Os equipamentos de digitalização tridimensional têm um alto custo de investimento, mesmo os de baixa precisão. A comunidade de entusiastas de software e hardware livre busca também distribuir e popularizar o conhecimento compartilhando suas descobertas e contribuindo abertamente com outras iniciativas. Buscamos nesse projeto construir um scanner 3D utilizando software e hardware livre utilizando componentes de baixo custo e fácil aquisição, estabelecendo seus limites técnicos, estimulando assim a adoção de técnicas de engenharia reversa. O processo de calibragem, captura e pós tratamento da nuvem de pontos obtidas foi detalhado na construção de modelos para comparação de dimensões e levantamento de características da superfície do material. / Mestre
9

Projeto e construção de um scanner tridimensional baseado no método de triangulação a laser utilizando softwares livres / Design and construction of a three-dimensional scanner based in laser triangulation method using free software

Moreira, Sandro Silva [UNESP] 06 December 2016 (has links)
Submitted by Sandro Moreira (moreira.sandro@gmail.com) on 2017-01-18T18:23:17Z No. of bitstreams: 1 SandroMoreira-DissertacaoMestradoFinal.pdf: 12934831 bytes, checksum: a63cb94b201b877dc272a7bccad284bc (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-23T19:48:34Z (GMT) No. of bitstreams: 1 moreira_ss_me_ilha.pdf: 12934831 bytes, checksum: a63cb94b201b877dc272a7bccad284bc (MD5) / Made available in DSpace on 2017-01-23T19:48:34Z (GMT). No. of bitstreams: 1 moreira_ss_me_ilha.pdf: 12934831 bytes, checksum: a63cb94b201b877dc272a7bccad284bc (MD5) Previous issue date: 2016-12-06 / A modelagem tridimensional muito já contribuiu com a indústria do entretenimento e agora tem sido amplamente utilizada na manufatura e criação de novos produtos. A possibilidade de se ter um modelo de um produto a um preço menor e com uma maior rapidez tem feito essa técnica ser cada vez mais aceita em todas as áreas da engenharia. Quando já se tem um modelo real e deseja-se realizar alguma modificação, simulação ou mesmo replicar o produto, a engenharia reversa muito pode contribuir, pois permite a obtenção do modelo tridimensional a partir do objeto real. Os equipamentos de digitalização tridimensional têm um alto custo de investimento, mesmo os de baixa precisão. A comunidade de entusiastas de software e hardware livre busca também distribuir e popularizar o conhecimento compartilhando suas descobertas e contribuindo abertamente com outras iniciativas. Buscamos nesse projeto construir um scanner 3D utilizando software e hardware livre utilizando componentes de baixo custo e fácil aquisição, estabelecendo seus limites técnicos, estimulando assim a adoção de técnicas de engenharia reversa. O processo de calibragem, captura e pós tratamento da nuvem de pontos obtidas foi detalhado na construção de modelos para comparação de dimensões e levantamento de características da superfície do material. / The three-dimensional modeling has contributed much to the entertainment industry and has now been widely used in manufacturing and creating new products. The possibility of having a model of a product at a lower price and a higher speed have made this technique is increasingly accepted in all fields of engineering. When there is already a real model and you want to make any changes, simulation or even replicate the product, reverse engineering can greatly contribute, as it allows to obtain three-dimensional model from the real object. The three-dimensional scanning equipment have a high investment cost, even low accuracy. The community of enthusiasts of open source and open hardware also distribute and popularize knowledge sharing his findings and openly contribute to other initiatives. We seek in this study, build a scanner 3D using free software and hardware components using low-cost and easy acquisition, establishing its technical limits, stimulating the adoption of reverse engineering techniques. The calibration, capture and post-treatment process of the cloud of points obtained was detailed in the construction of models for comparison of dimensions and survey of surface characteristics of the material.
10

Avaliação Comparativa dos Scanners 3D Artec MHT e Cyberware WBX para aplicações em Antropometria e Ergonomia / Comparative assessment of Artec MHT and Cyberware WBX 3D Scanners for applications in Anthropometry and Ergonomic Studies

Denise Silva Batista 29 January 2014 (has links)
A partir das dimensões dos indivíduos pode-se definir dimensionamentos adequados para os produtos e postos de trabalho, proporcionando segurança e conforto aos usuários. Com o avanço da tecnologia de digitalização de imagens (escaneamento) 3D, é possível tirar algumas medidas de maneira mais rápida e com a redução da presença do entrevistado durante o processo. No entanto, faltam estudos que avaliem estas tecnologias no Brasil, sendo necessária a realização de uma comparação das tecnologias e das respectivas precisões para que seu uso em pesquisas. Com o objetivo de oferecer métodos comparativos para escolha dos marcadores e equipamentos a serem utilizados em uma pesquisa antropométrica tridimensional da população brasileira, no presente estudo estão comparadas duas tecnologias de escaneamento: o sistema a laser WBX da empresa norte americana Cyberware e o sistema MHT da empresa russa Artec Group. O método para avaliação da precisão dimensional dos dados advindos desses equipamentos de digitalização de imagens 3D teve cinco etapas: Estudo dos processos de escaneamento; Escaneamento dos marcadores de pontos anatômicos; Escaneamento utilizando um corpo de prova cilíndrico; Escaneamento de um manequim; Escaneamento de um voluntário que teve seus pontos anatômicos marcados para a retirada de medidas. Foi feita uma comparação entre as medidas retiradas manualmente, por meio de antropômetro e virtualmente, com o auxílio do software de modelagem tridimensional Rhinoceros. Em relação aos resultados obtidos na avaliação do manequim e do voluntário, concluiu-se que a magnitude do erro absoluto é semelhante para ambos os scanners, e permanece constante independentemente das dimensões sob análise. As principais diferenças são em relação às funcionalidades dos equipamentos. / Only from the dimensions of individuals it is possible to define appropriate sizing for products and workplaces, providing security and comfort to users. With the evolution of 3D digital imaging technology (3D scanning), it is possible to take some measurements faster and reduce the need of the interviewee during the process. However, there are few studies that evaluate these technologies in Brazil. It is necessary to compare these equipments in order to know their precision so they can be used in researches. In order to choose anatomical markers and equipments, this study compares two different equipments: Cyberware WBX laser scanner and Artec Group MHT white light scanner. The method for assessing the dimensional accuracy of the data obtained from those scanning 3D imaging equipment had five steps: Study of the scanning processes; Scanning using a cylindrical object; Scanning a mannequin; Scanning a volunteer who had his anatomical points marked for taking measurements. The comparison was made between the measurements taken manually with an anthropometer and virtually using the 3D modeling software Rhinoceros. Based on results obtained in the evaluation of the mannequin and volunteer, it was concluded that the absolute error is similar for both scanners and remains constant regardless of the size under consideration. The main differences are the features of each equipment.

Page generated in 0.0486 seconds