Spelling suggestions: "subject:"silorane"" "subject:"diborane""
11 |
Análise das propriedades físico-químicas de compósitos auto-adesivos e bulk-fill = Analysis of physical-chemical properties of self-adhering and bulk-fill composites / Analysis of physical-chemical properties of self-adhering and bulk-fill compositesFugolin, Ana Paula Piovezan, 1987- 26 August 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T13:35:05Z (GMT). No. of bitstreams: 1
Fugolin_AnaPaulaPiovezan_D.pdf: 4905643 bytes, checksum: 75a91fcf559fc00359be8feeeb2d2a0c (MD5)
Previous issue date: 2015 / Resumo: Novos compósitos bulk-fill, autoadesivos e de menor contração foram desenvolvidos propondo mudanças na técnica restauradora incremental preconizada. Os objetivos desta pesquisa foram: 1) analisar os compósitos Tetric EvoCeram Bulk Fill (TEC), Surefil SDR (SDR), Vertise Flow (VF), Filtek Low Shrinkage (SIL) e compará-los com o compósito convencional Z100 (Z100) quanto à contração volumétrica, tensão de contração, grau de conversão, cinética, resistência à flexão e módulo de elasticidade; 2) avaliar a profundidade de polimerização e a resistência da união à tração de cavidades de Classe II restauradas com diferentes técnicas e diversas associações de materiais submetidas à ciclagem mecânica; e 3) analisar a adaptação marginal por microscopia eletrônica de varredura de restaurações de Classe II antes e após ciclagem mecânica e resistência coesiva. No capitulo 1, a contração volumétrica foi avaliada por dilatômetro de mercúrio e bonded disc (n=5) e a tensão de contração com Bioman (n=5). O grau de conversão foi analisado com espectroscopia de infravermelho próximo (NIR) (n=5) e a cinética por meio de optical bench (n=5). Resistência à flexão e módulo de elasticidade foram mensurados em ensaio com três pontos de apoio após 10 e 60 minutos da fotoativação. Os dados foram analisados por ANOVA e teste de Tukey (5%). VF apresentou os maiores valores de contração volumétrica e tensão de contração, enquanto que SIL obteve os menores. SDR apresentou a maior taxa de polimerização e os maiores valores de grau de conversão. VF apresentou os maiores valores de resistência à flexão após 10 e 60 minutos e Z100 os maiores valores de módulo de elasticidade. No capítulo 2, cavidades de Classe II ocluso-distais em terceiros molares humanos extraídos foram restauradas usando sistema adesivo convencional ¿ XP Bond (XP) ou à base de silorano (SSA) associado aos compósitos TEC, SDR, VF, SIL e Z100 inseridos por meio da técnica incremental (I) e bulk (B). Os grupos experimentais testados foram: XP-Z-B, XP-Z-I, SSA-Z-B, SSA-Z-I, XP-TEC-B, XP-TEC-I, XP-SDR-Z100, SSA-SDR-Z100, VF-Z-B e SSA-SIL-B (n=8). Metade do total das amostras foi preparada para obtenção de palitos e submetida ao teste de resistência da união à microtração após sete dias de armazenagem, enquanto outra metade foi submetida à ciclagem mecânica antes do ensaio de resistência da união. A profundidade de polimerização foi mensurada em restaurações com 4,0 mm de profundidade removidas da cavidade e submetidas ao ensaio de dureza Knoop (n=3). Os resultados foram analisados por ANOVA e teste de Tukey (5%). Quanto à resistência de união o grupo XP-SDR-Z apresentou os maiores valores em ambas as superfícies (oclusal e cervical) nos grupos ciclados ou não. Os menores valores foram exibidos por VF-Z-B em ambas as superfícies para os grupos não ciclados e SSA-SDR-Z para os ciclados. Em relação à profundidade de polimerização, VF apresentou a maior redução da dureza, enquanto os demais compósitos apresentaram valores de redução menores do que 20%. No capítulo 3, as cavidades de Classe II restauradas seguiram as mesmas etapas dos grupos experimentais apresentados no capítulo 2 (n=5) e foram submetidas ao ensaio de ciclagem mecânica; porém, foram previamente moldadas para obtenção de replicas para análise da integridade marginal em microscopia eletrônica de varredura. As imagens foram analisadas pelo software Image J para verificar a porcentagem de fendas. Os compósitos utilizados para restaurar as cavidades foram submetidos ao teste de resistência coesiva (n=5). Os resultados foram analisados por ANOVA e teste de Tukey (5%). A análise da adaptação marginal qualitativa e quantitativa mostrou alteração significativa antes e após a ciclagem mecânica apenas para todos o grupo SSA-Z-B. Os resultados de resistência coesiva mostraram que Z100, SDR e SIL apresentaram os maiores valores, seguido de TEC. VF apresentou os menores valores. Concluiu-se que os novos compósitos apresentam propriedades comparáveis e, em algumas situações, melhores quando comparado ao compósito convencional / Abstract: New bulk-fill, self-adhering and low shrinkage materials were developed and purposed significant changes in the preconized incremental restorative technique. The aims of this research were: 1) analyze the new composites represented by Tetric EvoCeram Bulk Fill (TEC), Surefil (SDR), Vertise Flow (VF), Filtek Low Shrinkage (SIL) and compare them with the conventional composite Z100 (Z100) in relation to volumetric shrinkage, stress of polymerization, degree of conversion, kinetics, flexural strength and modulus; 2) evaluate depth of cure of different composites and microtensile bond strength of Class II cavities filled by different restorative techniques and materials association submitted to mechanical fatigue-cycling test; and 3) analyze marginal adaptation by scanning electron microscopy (SEM) of Class II restoration before and after mechanical cycling, and ultimate tensile strength. In the charter 1, the volumetric shrinkage was evaluated by mercury dilatometer and bonded-disc techniques (n=5) and stress of polymerization by Bioman instrument (n=5). Degree of conversion was analyzed with NIR-spectroscopy (n=5) and the kinetics by the optical bench (n=5). Flexural strength and modulus were carried out using a three-point bending test after 10 and 60 minutes after photocuring. Results were analyzed by ANOVA and Tukey¿s test (5%). VF showed the highest values of volumetric shrinkage and stresses of polymerization and SIL the lowest ones. SDR obtained the highest rate of polymerization and the highest degree of conversion values. VF presented the highest values of flexural strength in both tested times, and Z100 the highest values of modulus. In the charter 2, Class II occluso-distal cavities (6 x 2 x 4 mm) in extracted human molars were restored using a etch-and-rinse adhesive system ¿ XP Bond (XP) or silorane-based (SSA) associated to TEC, SDR, VF, SIL and Z100 composites placed by incremental (I) or bulk (B) technique. The tested experimental groups were: XP-Z-B, XP-Z-I, SSA-Z-B, SSA-Z-I, XP-TEC-B, XP-TEC-I, XP-SDR-Z100, SSA-SDR-Z100, VF-Z-B e SSA-SIL-B (n=8). Half of the samples were prepared to obtain sticks and submitted to the microtensile bond strength test after 7 days of storage. The other samples were submitted to the mechanical fatigue-cycling test before the microtensile bond strength test. Depth of cure was carried out in restorations with 4.0 mm of depth, removed and submitted to Knoop hardness test (n=3). Results were statistically analyzed by ANOVA and Tukey¿s test (5%). In relation to microtensile bond strength, in overall, XP-SDR-Z showed the highest values in both analyzed surfaces (occlusal and cervical) in cycling and no-cycling groups. The lowest values were exhibited by VF-Z-B in both analyzed surfaces in no-cycling groups and SSA-SDR-Z in cycling groups. In relation to depth of cure, VF obtained the lowest top-to-bottom ratio, while the other tested composites exhibited less than 20% of reduction. In the charter 3, Class II cavities were prepared following the same steps described in charter 2 (n=5) and were carried out to mechanical fatigue-cycling test. However, impressions were made before and after to obtain replicas to SEM analysis of the marginal integrity. The micrographs were analyzed by Image J software to measure the discontinuity percentage. The composites used in the cavities were submitted to the ultimate tensile strength (UTS) (n=5). Results were statistically analyzed by ANOVA and Tukey¿s test (5%). Marginal adaptation analysis did not show significant alteration before and after cycling for all groups except to SSA-Z-B where cracks and gaps were found in the adhesive interface. In relation to UTS results Z100, SDR and SIL showed the highest results, followed by TEC. VF exhibited the lowest values. It is possible to conclude that new composites show comparable properties and in some situation better than conventional material / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários
|
12 |
Influência da variação da densidade de potência na contração de polimerização e adaptação marginal de resinas compostas à base de metacrilato e siloranoBaseggio, Wagner 16 September 2011 (has links)
Este estudo avaliou quantitativamente a contração de polimerização em função do aumento dos valores de densidade de potência irradiados em compósitos à base de metacrilatos e silorano, e qualitativamente a interface restauradora em relação à abertura de fendas marginais, em função da variação do tipo de substrato dentário. As resinas Filtek Z250 e Filtek P90 foram fotoativadas com 200, 400, 600, 800 e 1000 mW/cm2, em um volume constante de 12 mm3, e os valores de contração aferidos por meio da máquina de ensaios universal. Para análise qualitativa da interface restauradora, preparos cavitários classe V de 2x2x2 mm foram restaurados em incisivos bovinos, fotoativados com os mesmos valores de irradiância, e analisados em microscopia eletrônica de varredura nas interfaces da parede circundante em esmalte, parede circundante em dentina e parede axial. Os resultados quantitativos da contração de polimerização foram analisados pelo teste ANOVA a dois critérios e Tukey (p0,05), enquanto para os dados qualitativos os testes Mann-Whitney, Kruskal-Wallis e Miller foram empregados. O aumento progressivo da densidade de potência influenciou diretamente na contração de polimerização dos materiais estudados, não obstante a resina composta à base de silorano ter demonstrado valores significativamente menores. A integridade marginal sofreu influência do subtrato dentário bem como da densidade de potência utilizada, para as duas resinas estudadas. / Shrinkage is a limitation of resin composite, compromising the clinical longevity of the restorative procedure. In an attempt to reduce their harmful effects, researchers have studied monomers with lower values of contraction. As a result, low-shrinkage composites wer developed. This study evaluated quantitatively the shrinkage by a universal testing machine as a function of power density increase based on methacrylates, comparing them with silorane based resin, and qualitatively regarding gap formation between the adhesive interface as function of tooth substrate. Resin Filtek P90 and Filtek Z250 were polymerized with the device Blue Star 3 with 200, 400, 600, 800 and 1000 mW/cm2 keeping volume constant in 12 mm3. For qualitative analysis of restorative interface, class V cavity preparations in bovine incisors were restored in (2x2x2 mm), photoactivated with the same values of irradiance, and analyzed by scanning electron microscopy at the interface of the wall surrounding enamel, dentin and axial. The quantitative results of the polymerization shrinkage were analyzed by two-way ANOVA and Tukey\'s test (p0,05), while qualitative data for the Mann-Whitney, Kruskal-Wallis and Miller were employed. The progressive increase in power density directly influenced the polymerization shrinkage of the materials studied, despite the silorane based resin have demonstrated significantly lower values. The marginal integrity was influenced by the dental substrate and the power density used.
|
13 |
Avaliação da resistência de união entre dentina preparada por laser e um sistema adesivo a base de silorano, variando a técnica de aplicação e umidade do substrato /Oliveira, Rodrigo Simões de. January 2011 (has links)
Orientador: César Rogério Pucci / Banca: Sileno Correa Brum / Banca: Alessandra Bühler Borges / Resumo: O objetivo deste trabalho foi avaliar a resistência de união à dentina do sistema adesivo autocondicionante P-90 System Adhesive Self-Etch Primer e Bond utilizado com a resina composta Filtek P-90, variando a técnica de aplicação (ativa e passiva), a umidade dentinária (dentina úmida ou seca) e a utilização ou não do laser de Er:YAG Kavo Key Laser 3. Foram utilizados 90 incisivos bovinos recém extraídos, limpos e que tiveram as raízes removidas. O esmalte vestibular foi aplainado com a finalidade de expor a dentina. Os espécimes foram embutidos em resina acrílica utilizando uma matriz de silicone. A dentina exposta na superfície vestibular foi desgastada na Politriz para padronização da smear layer. Os espécimes foram divididos aleatoriamente em 9 grupos (10 dentes) divididos de acordo com o material e a técnica de aplicação do sistema adesivo: Nos Grupos 1 (controle), foi utilizado o sistema adesivo P-90 System Adhesive Self-Etch Primer e Bond utilizado com a resina composta Filtek P-90 de acordo com indicação do fabricante. Os demais grupos foram divididos em dois subgrupos com e sem aplicação do laser Er:YAG (60 mJ de energia e 2 Hz de frequência, 30 s) previamente à aplicação do sistema adesivo. Dentro de cada subgrupo o sistema adesivo foi aplicado na dentina úmida e seca de forma ativa e passiva. Sobre a área onde foi aplicado o sistema adesivo foi adaptada uma matriz de silicone, com uma perfuração central de forma quadrada com dimensões 6x6x4 mm onde foi inserida a resina composta, de acordo com o grupo e com as instruções do fabricante. Os corpos de prova foram submetidos à ciclagem termomecânica e seccionados em palitos, os quais foram submetidos ao teste de microtração na Máquina de Ensaios Universais DL-1000. Os dados obtidos foram submetidos à ANOVA e ao Teste de Tukey (α= 5%). As fraturas foram classificadas e apenas as fraturas ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the bond strength to dentin of the system self-etch adhesives P-90 System Adhesive Self-Etch Primer and Bond used with composite resin Filtek P-90, varying the application technique (active and passive), humidity dentin (dentin wet or dry) and use or not of the Er: YAG Laser Kavo Key 3. We used 90 recently extracted bovine incisors, cleaned and had the roots removed. The enamel was flattened in order to expose the dentin. The specimens were embedded in acrylic resin using a silicone matrix. The exposed dentin on the buccal surface was worn on the polisher to standardize smear layer. The specimens were randomly divided into nine groups (10 teeth) divided according to the material and technical application of the adhesive system: In Group 1 (control), the adhesive system used was P-90 System Adhesive Self-Etch Primer and Bond used with composite resin Filtek P-90 according to the manufacturer's specifications. The other groups were divided into two subgroups with and without application of Er: YAG laser (60 mJ energy and 2 Hz frequency, 30 s) prior to application of the adhesive system. Within each subgroup the adhesive system was applied to the wet and dry dentin of active and passive. About the area where it was applied to the adhesive system was adapted a silicone matrix, with a central perforation of square shape with dimensions 6x6x4 mm which was inserted into the composite resin, according to the group and with the manufacturer's instructions. The samples were submitted to thermomechanical cycling and cut into sticks, which were tested for microtensile testing machine Universal DL-1000. The data were subjected to ANOVA and Tukey's test (α = 5%). The fractures were classified and only the adhesive or mixed fractures were observed in a scanning electron microscope. The bond strength values were higher in groups G3, G7 and G8, ... (Complete abstract click electronic access below) / Mestre
|
14 |
Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on siloraneRebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
|
15 |
Avaliação da resistência de união entre dentina preparada por laser e um sistema adesivo a base de silorano, variando a técnica de aplicação e umidade do substratoOliveira, Rodrigo Simões de [UNESP] 08 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-07-08Bitstream added on 2014-06-13T18:51:38Z : No. of bitstreams: 1
oliveira_rs_me_sjc.pdf: 4540691 bytes, checksum: 247942cea62533dbe305681a64b0911c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a resistência de união à dentina do sistema adesivo autocondicionante P-90 System Adhesive Self-Etch Primer e Bond utilizado com a resina composta Filtek P-90, variando a técnica de aplicação (ativa e passiva), a umidade dentinária (dentina úmida ou seca) e a utilização ou não do laser de Er:YAG Kavo Key Laser 3. Foram utilizados 90 incisivos bovinos recém extraídos, limpos e que tiveram as raízes removidas. O esmalte vestibular foi aplainado com a finalidade de expor a dentina. Os espécimes foram embutidos em resina acrílica utilizando uma matriz de silicone. A dentina exposta na superfície vestibular foi desgastada na Politriz para padronização da smear layer. Os espécimes foram divididos aleatoriamente em 9 grupos (10 dentes) divididos de acordo com o material e a técnica de aplicação do sistema adesivo: Nos Grupos 1 (controle), foi utilizado o sistema adesivo P-90 System Adhesive Self-Etch Primer e Bond utilizado com a resina composta Filtek P-90 de acordo com indicação do fabricante. Os demais grupos foram divididos em dois subgrupos com e sem aplicação do laser Er:YAG (60 mJ de energia e 2 Hz de frequência, 30 s) previamente à aplicação do sistema adesivo. Dentro de cada subgrupo o sistema adesivo foi aplicado na dentina úmida e seca de forma ativa e passiva. Sobre a área onde foi aplicado o sistema adesivo foi adaptada uma matriz de silicone, com uma perfuração central de forma quadrada com dimensões 6x6x4 mm onde foi inserida a resina composta, de acordo com o grupo e com as instruções do fabricante. Os corpos de prova foram submetidos à ciclagem termomecânica e seccionados em palitos, os quais foram submetidos ao teste de microtração na Máquina de Ensaios Universais DL-1000. Os dados obtidos foram submetidos à ANOVA e ao Teste de Tukey (α= 5%). As fraturas foram classificadas e apenas as fraturas... / The objective of this study was to evaluate the bond strength to dentin of the system self-etch adhesives P-90 System Adhesive Self-Etch Primer and Bond used with composite resin Filtek P-90, varying the application technique (active and passive), humidity dentin (dentin wet or dry) and use or not of the Er: YAG Laser Kavo Key 3. We used 90 recently extracted bovine incisors, cleaned and had the roots removed. The enamel was flattened in order to expose the dentin. The specimens were embedded in acrylic resin using a silicone matrix. The exposed dentin on the buccal surface was worn on the polisher to standardize smear layer. The specimens were randomly divided into nine groups (10 teeth) divided according to the material and technical application of the adhesive system: In Group 1 (control), the adhesive system used was P-90 System Adhesive Self-Etch Primer and Bond used with composite resin Filtek P-90 according to the manufacturer's specifications. The other groups were divided into two subgroups with and without application of Er: YAG laser (60 mJ energy and 2 Hz frequency, 30 s) prior to application of the adhesive system. Within each subgroup the adhesive system was applied to the wet and dry dentin of active and passive. About the area where it was applied to the adhesive system was adapted a silicone matrix, with a central perforation of square shape with dimensions 6x6x4 mm which was inserted into the composite resin, according to the group and with the manufacturer's instructions. The samples were submitted to thermomechanical cycling and cut into sticks, which were tested for microtensile testing machine Universal DL-1000. The data were subjected to ANOVA and Tukey's test (α = 5%). The fractures were classified and only the adhesive or mixed fractures were observed in a scanning electron microscope. The bond strength values were higher in groups G3, G7 and G8, ... (Complete abstract click electronic access below)
|
16 |
Efeito do fator cavitário na resistência adesiva à dentina de um sistema restaurador à base de silorano / C factor effect on bond strength of a restorative system based on siloraneRebecca Cruz 07 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar o efeito do fator C na resistência adesiva à dentina humana de um compósito à base de silorano, comparando-o com um compósito à base de metacrilato. Foram utilizados 40 molares humanos hígidos. Em metade da amostra foi realizado um preparo do tipo Classe I, com dimensões de 4x4 mm e 2 mm de profundidade, enquanto na outra metade foi realizado um preparo virtual (flat) com auxílio de uma matriz de teflon branco, com as mesmas dimensões da cavidade (4x4x2 mm), apoiada na superfície de dentina exposta. Cada grupo foi divido em dois, de acordo com o sistema restaurador: Sistema Adesivo P90 e resina Filtek P90; Adper Scotchbond Multiuso e resina Filtek Z350 XT (3M ESPE). Após a aplicação do sistema adesivo segundo as especificações do fabricante, as cavidades (real e virtual) foram preenchidas com as resinas (Z350 XT e P90) em dois incrementos. Foi realizada a fotoativação de cada incremento durante 25s. Após uma semana, as coroas foram seccionadas, obtendo-se espécimes constituídos de resina/dente na forma de um paralelepípedo (palitos). Estes palitos foram utilizados para o teste de microtração (Emic), onde a resistência adesiva na unidade MPa foi calculada. Os resultados foram avaliados estatisticamente pelo teste de análise de variância ANOVA One-Way (p = 0,05), e pelo teste de múltiplas comparações Student Newman Keuls. Foi observada uma diferença estatística entre a resina P90 (flat= 16,137,7 MPa e Cavidade= 16,759,0 MPa) e a Z350 XT (flat= 25,8211,6 MPa e Cavidade=24,4713,5 MPa), independentemente do tipo de cavidade restaurada. E não foi possível observar diferença estatística entre os tipos de cavidades (real ou virtual) restauradas com a mesma resina. Através dos testes realizados, foi possível concluir que: o fator C não afetou a resistência adesiva dos dois sistemas restauradores utilizados, e o tipo de sistema restaurador afeta a resistência adesiva, sendo que o sistema à base de silorano apresenta resultados inferiores ao de metacrilato. / The purpose of this study is to evaluate the effect of the C factor in the bond strength of a composite based on silorane to human dentin, comparing its results with a methacrylate-based composite. A total of 40 human molars were used. In half of this sample was used a Class I standard preparation method, comprising the dimensions of 4x4 mm and 2 mm deep, while with the other half was used a virtual preparation method (flat), being applied a white Teflon matrix, respecting the same dimensions cavity (4x4x2 mm), supported on the surface of exposed dentin. Each group was divided into two parts, in accordance with the 2 different restorative systems: P90 Adhesive System and Filtek P90; Filtek Z350 XT and Adper Scotchbond Multipurpose (3 ESPE). Based on manufacturer's specifications the adhesive system was applied , the cavities (real and virtual) were filled with the resins (Z350 XT and P90) in two increments. Polymerization was performed for each increment during 25 seconds. After one week, the crowns were sectioned, obtaining specimens made of resin / tooth in the form of a parallelepiped (stick-shaped). These sticks were used in a microtensile test (Emic), where the bond strength was calculated in Mpa unit . It was used the analysis of variance One-Way ANOVA (p = 0.05) and also, the Student Newman Keuls test for multiple comparisons to evaluate the results statistically. It was observed a statistical difference between the P90 resin (flat = 16.137.7 MPa and cavity = 16.759.0 MPa) and Z350 XT (flat = 25.8211.6 MPa and cavity = 24.4713.5 MPa), regardless of the cavity restored. And it was not possible to observe a statistical difference between the types of cavities (real or flat) restored with the same composite. The conclusion of the tests is: the C factor did not affect the bond strength of two restorative systems applied, and the type of restorative system affects the bond strength, and the system based on silorano presents inferior results than to methacrylate system.
|
17 |
Influência da variação da densidade de potência na contração de polimerização e adaptação marginal de resinas compostas à base de metacrilato e siloranoWagner Baseggio 16 September 2011 (has links)
Este estudo avaliou quantitativamente a contração de polimerização em função do aumento dos valores de densidade de potência irradiados em compósitos à base de metacrilatos e silorano, e qualitativamente a interface restauradora em relação à abertura de fendas marginais, em função da variação do tipo de substrato dentário. As resinas Filtek Z250 e Filtek P90 foram fotoativadas com 200, 400, 600, 800 e 1000 mW/cm2, em um volume constante de 12 mm3, e os valores de contração aferidos por meio da máquina de ensaios universal. Para análise qualitativa da interface restauradora, preparos cavitários classe V de 2x2x2 mm foram restaurados em incisivos bovinos, fotoativados com os mesmos valores de irradiância, e analisados em microscopia eletrônica de varredura nas interfaces da parede circundante em esmalte, parede circundante em dentina e parede axial. Os resultados quantitativos da contração de polimerização foram analisados pelo teste ANOVA a dois critérios e Tukey (p0,05), enquanto para os dados qualitativos os testes Mann-Whitney, Kruskal-Wallis e Miller foram empregados. O aumento progressivo da densidade de potência influenciou diretamente na contração de polimerização dos materiais estudados, não obstante a resina composta à base de silorano ter demonstrado valores significativamente menores. A integridade marginal sofreu influência do subtrato dentário bem como da densidade de potência utilizada, para as duas resinas estudadas. / Shrinkage is a limitation of resin composite, compromising the clinical longevity of the restorative procedure. In an attempt to reduce their harmful effects, researchers have studied monomers with lower values of contraction. As a result, low-shrinkage composites wer developed. This study evaluated quantitatively the shrinkage by a universal testing machine as a function of power density increase based on methacrylates, comparing them with silorane based resin, and qualitatively regarding gap formation between the adhesive interface as function of tooth substrate. Resin Filtek P90 and Filtek Z250 were polymerized with the device Blue Star 3 with 200, 400, 600, 800 and 1000 mW/cm2 keeping volume constant in 12 mm3. For qualitative analysis of restorative interface, class V cavity preparations in bovine incisors were restored in (2x2x2 mm), photoactivated with the same values of irradiance, and analyzed by scanning electron microscopy at the interface of the wall surrounding enamel, dentin and axial. The quantitative results of the polymerization shrinkage were analyzed by two-way ANOVA and Tukey\'s test (p0,05), while qualitative data for the Mann-Whitney, Kruskal-Wallis and Miller were employed. The progressive increase in power density directly influenced the polymerization shrinkage of the materials studied, despite the silorane based resin have demonstrated significantly lower values. The marginal integrity was influenced by the dental substrate and the power density used.
|
18 |
Análise das propriedades mecânicas de uma resina composta à base de silorano / Analysis of the mechanical properties of a silorane based compositeEloá de Aguiar Gazola 04 June 2014 (has links)
Este estudo investigou propriedades mecânicas do compósito silorano em dois capítulos. Capítulo A Objetivo: avaliou a resistência de união entre a estrutura dental e um composto à base de silorano, após o clareamento dental. Método: Sessenta incisivos bovinos foram distribuídos aleatoriamente em seis grupos (n=10), de acordo com o período de armazenamento entre o tratamento clareador e a restauração com compósito à base de silorano. O tratamento clareador com peróxido de carbamida à 10% seguiu um protocolo de quatro horas diárias durante duas semanas. Após o período de armazenamento, as cavidades foram preparadas e restauradas com uma resina composta à base de silorano. Resultado: Após o tratamento clareador e os devidos períodos de armazenagem, nenhuma diferença significativa foi observada nos resultados de resistência adesiva (p>0,05). Conclusão: a resistência adesiva entre o compósito à base de silorano e o substrato dental não foi afetada pelo tratamento clareador com 10% de peróxido de carbamida. Capítulo B Objetivo: avaliou a resistência coesiva entre as camadas de resinas compostas à base metacrilato e silorano e a microdureza Knoop (KHN) após ciclos de erosão e abrasão. Método: Para a resistência coesiva, vinte amostras foram feitas com cada compósito, metacrilato (MC) e silorano (SC) (n=10). As amostras foram divididas em quatro grupos, de acordo com tipo e quantidade de incrementos de resina composta. O teste de microtração foi realizado 24h após a confecção das amostras. Para a análise da KHN, após os ciclos de erosão/abrasão, foram produzidas quarenta amostras de cada resina composta testada (MC e SC). As amostras foram distribuídas em oito grupos (n=10) de acordo com tipo de compósito e tipo de bebida envolvida no processo de erosão (controle, suco de laranja, Smirnoff Ice e Gatorade) e abrasão com dentifrício de alta abrasividade. Resultado - não foram observadas diferenças na resistência coesiva entre as camadas incrementais dos compósitos estudados (p> 0,05). Os resultados de KHN dos grupos MC apresentaram menor valor para o Smirnoff Ice (p<0,05), no entanto, para os grupos SC nenhuma diferença foi observada (p>0,05). Conclusão: a resistência coesiva entre as camadas incrementais de ambos compósitos testados não foi afetada pelo oxigênio; as bebidas, em conjunto com a abrasão, não tiveram capacidade de interferir na KHN dos compósitos testados, exceto o Smirnoff Ice para o MC. / This study investigated the mechanical properties of the silorane based composite in two chapter. Chapter A Aim: evaluated the bond strength between the dental structure and a silorane-based composite (SC), after bleaching treatment. Method: Sixty bovine incisors were randomly distributed into six groups (n=10) according to the storage period between the bleaching treatment and the SC restoration. The bleaching treatment followed a protocol of 10% carbamide peroxide with one application during four hours per day during two weeks. After the period of storage, cavities were made and filled with SC. Results: After the periods of bleaching treatment, no significant difference was observed in the results of push out bond strength between the SC and the bleached substrate (p>0.05). Conclusion: the bond strength between the SC and the dental substrate was not affected by the bleaching treatment with 10% carbamide peroxide. Chapter B Aim: evaluated the bond strength between incremental layers of methacrylate and silorane composites and the micro hardness Knoop (KHN) after erosion and abrasion cycles. Method: for the bond strength, twenty samples were made with each composite, methacrylate (MC) and silorane (SC) (n=10). The samples were divided into four groups according composite type and quantity of increments. The microtensile test was performed 24 h after the samples were made. For the KHN test, after erosion/abrasion process, forty samples of each composite tested (MC and SC) were made. The samples were distributed into eight groups (n=10) according composite type and beverage type involved in the erosion process (control, orange juice, Smirnoff Ice and Gatorade) and abrasion with high abrasivity detifrice. Results: no differences were observed in the bond strength between increment layers when the same composite was analyzed (p>0.05). The results of KHN in the MC groups showed smaller value for the Smirnoff Ice (p<0.05), however for the SC groups no differences were found (p>0.05). Conclusion: the bond strength between incremental layers of SC was not affected by the oxygen; the others beverages, jointly with the abrasion, have no capacity to interfere in the KHN of the composites tested.
|
19 |
Effect of surface treatments on microtensile bond strength of repaired aged silorane resin compositePalasuk, Jadesada January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Background: A silorane based resin composite, Filtek LS restorative, has been introduced to overcome the polymerization shrinkage of the methacrylate based resin composite. The repair of resin composite may hold clinical advantages. Currently, there is no available information regarding the repair potential of silorane resin composite with either silorane or methacrylate based resin composite. Objectives: The purpose of this study was to compare the repaired microtensile bond strength of aged silorane resin composite using different surface treatments and either silorane or methacrylate based resin composite. Methods: One hundred and eight silorane resin composite blocks (Filtek LS) were fabricated and aged by thermocycling between 8oC and 48oC (5000 cycles). A control (solid resin composite) and four surface treatment groups (no treatment, acid treatment, aluminum oxide sandblasting and diamond bur abrasion) were tested. Each treatment group was randomly divided in half and repaired with either silorane resin composite (LS adhesive) or methacrylate based resin composite (Filtek Z250/Single Bond Plus). Specimens were 12 blocks and 108 beams per group. After 24 hours in 37oC distilled water, microtensile bond strength testing was performed using a non-trimming technique. Fracture surfaces were examined using an optical microscopy (20X) to determine failure mode. Data was analyzed using Weibull-distribution survival analysis. Results: Aluminum oxide sandblasting followed by silorane or methacrylate based resin composite and acid treatment with methacrylate based resin composite provided insignificant differences from the control (p>0.05). All other groups were significantly lower than the control. Failure was primarily adhesive in all groups. Conclusion: Aluminum oxide sandblasting produced comparable microtensile bond strength compared to the cohesive strength of silorane resin composite. After aluminum oxide sandblasting, aged silorane resin composite can be repaired with either silorane resin composite with LS system adhesive or methacrylate based resin composite with methacrylate based dentin adhesive.
|
Page generated in 0.0434 seconds