• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 250
  • 117
  • 51
  • 39
  • 30
  • 10
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 627
  • 627
  • 260
  • 177
  • 163
  • 163
  • 123
  • 115
  • 113
  • 111
  • 109
  • 108
  • 102
  • 92
  • 78
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Caracterização qualitativa do perfil volátil de vinhos espumantes brasileiros elaborados com um assemblage inovador submetidos a diferentes condições de segunda fermentação

Palma, Aline Schwertner January 2014 (has links)
Os vinhos espumantes elaborados pelo método Tradicional são elaborados, comumente, a partir das uvas Chardonnay, Pinot Noir, Chadonnay, Riesling, Viognier, Trebbiano e Pinot Noir e os componentes voláteis destes espumantes já têm merecido a atenção de diversos estudos científicos. Entretanto, vinhos espumantes produzidos a partir de outros varietais de uvas ainda não foram alvo de pesquisas científicas. A segunda fermentação ocorre dentro da garrafa e acaba por conferir uma maior complexidade aromática ao espumante produzido pelo método Tradicional, devido ao contato do vinho com as leveduras em meio redutor, por um determinado período de tempo. Isto acontece devido aos produtos secundários do metabolismo das leveduras, durante a conversão de açúcares em etanol e dióxido de carbono. Esta conversão depende dos nutrientes adicionados, chamados adjuvantes de fermentação, bem como da espécie de levedura utilizada, visto que cada levedura possui um metabolismo diferente para a utilização dos nutrientes e açúcares presentes no vinho base. Assim, objetivou-se, neste trabalho, caracterizar os componentes voláteis de vinhos espumantes de uma vinícola gaúcha, que emprega um assemblage inovador, empregando uvas Chadonnay, Riesling, Viognier, Trebbiano e Pinot Noir. Do assemblage deste vinho base utilizou-se, para segunda fermentação, duas espécies de leveduras comerciais: Saccharomyces cerevisiae e Saccharomyces bayanus. Para cada levedura utilizada na fermentação do vinho base, oito diferentes adjuvantes de fermentação foram empregados. A determinação dos compostos voláteis se deu através da técnica de microextração em fase sólida no modo headspace (HS-SPME) e cromatografia gasosa acoplada a detector de espectrometria demassa quadrupolar (GC/MS). Ao total, 25 compostos foram tentativamente identificados nos vinhos em estudo, sendo os compostos majoritários citados a seguir, com sua possível contribuição para o aroma destes vinhos: octanoato de etila (aroma de fruta), álcool isoamílico (aroma de banana), ácido octanoico (aroma de pimentão) e álcool feniletílico (aroma floral). O fenetil fenilacetato, um dos compostos minoritários tentativamente identificado em alguns dos vinhos, até então não reportado em vinho espumante, é associado a aroma frutado. Não foi possível distinguir subgrupos entre os 16 vinhos em estudo, provenientes de diferentes condições na segunda fermentação, quando as áreas cromatográficas dos compostos voláteis destes 16 vinhos foram submetidas a análise de cluster. Isto implica em que, nas condições experimentais deste estudo, não foi possível distinguir os voláteis dos vinhos fermentados (2ª fermentação) com S. cereviseae e os fermentados com S. bayanus. A mesma análise de cluster mostrou a subdivisão dos compostos voláteis dos 16 vinhos em dois grupos, os quais se distinguiram, provavelmente, devido aos diferentes adjuvantes nutricionais empregados: fosfato e Thiazote. Desta forma, através de análise qualitativa por HS-SPME-GC/MS, foi possível verificar a homogeneidade do perfil volátil dos 16 vinhos espumantes, obtidos a partir de diferentes adjuvantes de fermentação e duas espécies distintas de leveduras Saccharomyces sp, além de comparar os componentes voláteis presentes nestes espumantes com aqueles reportados na literatura para outros vinhos espumantes. / Sparkling wines elaborated by Traditional Method are usually produced by the grapes Chardonnay, Pinot Noir and Riesling, in which the volatile compounds of these sparkling wines have been calling attention to scientific studies. However, sparkling wines produced by other varietal grapes have not been a target of scientific research yet. The second fermentation occurs inside the bottle, in which confer a greater aromatic complexity to the sparkling wine produced by Traditional Method, due to the contact of it with lees in a reducing medium during a certain period of time. This happens due to secondary products of yeast metabolism, during the conversion of sugar in ethanol and carbon dioxide. This conversion depends on the nutrients added, called fermentation adjuvants, as the yeast used, since each one has a different metabolism for using this nutrients and sugars presented in the base wine. Thus, this work aims to characterize the volatile compounds of a south Brazilian winery, which use an innovative assemblage, using the grapes Chardonnay, Riesling, Viognier, Trebbiano and Pinot Noir. To the base wine, two different commercial yeasts were added: Saccharomyces cerevisiae and Saccharomyces bayanus to the performance of second fermentation. To each yeast used for fermenting the base wine, eight different fermentation adjuvants were used. The determination of volatile compounds were performed by Headspace solid-phase Microextraction (HS-SPME) and gas chromatography coupled to a mass quadrupole spectrometry (GC/MS). In total, 25 compounds were tentatively identified in the studied sparkling wines, being the majority listed as it follows, with their possible contribution to these sparkling wines aroma: ethyl octanoate (fruity), isoamyl alcohol (banana), octanoic acid (green pepper), and phenethyl alcohol (flower). Phenethyl phenylacetate, one of the minority compounds tentatively identified in some of the sparkling wines, is associated with fruity aroma. It was not possible to distinguish subgroups from different conditions during the second fermentation, when submitting the chromatographic areas of volatile compounds to cluster analysis. It implies that, under the experimental conditions of these study, it was not possible to differ the volatile compounds of the fermented (2nd fermentation) with S. cerevisiae and those which were fermented with S. bayanus. The same cluster analysis showed a subdivision of volatile compounds of the 16 wines in two groups, in which were probably distinguished due to the different nutritional adjuvants used: phosphate and Thiazote. Thus, throughout qualitative analysis by HS-SPME-GC/MS, it was possible to verify the homogeneity of volatile profile of the 16 sparkling wines, obtained by different fermentation adjuvants and two different yeast species of Saccharomyces sp, besides the comparison of volatile compounds presented in these sparkling wines with those others reported in the literature.
282

Desenvolvimento de fases monolíticas para métodos de extração aplicados a análise LC-UV de herbicidas em amostras de água / Development of monolithic phases for extraction methods applied to LC-UV analysis of herbicides in water samples

Soares, Francielle Queiroz 08 June 2018 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-06-21T13:56:35Z No. of bitstreams: 2 Tese - Francielle Queiroz Soares - 2018.pdf: 4062174 bytes, checksum: caec2644f4aa247943bf36592f90e826 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-06-27T11:03:01Z (GMT) No. of bitstreams: 2 Tese - Francielle Queiroz Soares - 2018.pdf: 4062174 bytes, checksum: caec2644f4aa247943bf36592f90e826 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-27T11:03:01Z (GMT). No. of bitstreams: 2 Tese - Francielle Queiroz Soares - 2018.pdf: 4062174 bytes, checksum: caec2644f4aa247943bf36592f90e826 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-06-08 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / Monolithic polymers can be defined as continuous porous polymers, synthesized in situ in a mold. These materials have been used in chromatographic applications due to the combination of high surface area with excellent permeability and mass transport properties. In this work, monolithic polymers based on styrene and divinylbenzene were synthesized by thermal initiation via bulk polymerization in the presence of different diluents; and via high internal phase emulsion polymerization in presence and absence of toluene as diluent. The monoliths produced via bulk polymerization, which were synthesized in the presence of binary mixtures tetrahydrofuran/decanol and toluene/decanol as polymerization diluents in the ratio 15:85 (v/v) showed mechanical resistance to be applied as extractive phases. Both formulations produced polymers with macroporous characteristics and the tetrahydrofuran/decanol mixture presented larger channels, resulting in higher permeability, in this way it was used as extraction phase for the technique of preparation of samples based on a device of sorptive extraction of micropipette tip (DPX) applied to the determination of triazines in water samples. Under optimized conditions the absolute recovery for the triazines varied from 28 to 64%. The monoliths produced by high internal phase emulsion polymerization showed macroporosity. We have found that the effect of the solvent is more significant for the increase in surface area and the volume and mean diameter of pores than the effect of the reduction of these by the increase in velocity. With this, the monolith prepared in the presence of toluene at a speed of 3000 rpm obtained a larger surface area and a larger volume and pore diameter, resulting in a higher permeability. The surface of this monolith was modified with polypyrrole, to verify this film on the selectivity of the resulting phase. When submitted to the extraction process using solid phase extraction devices (SPE), the monolith covered with PPY films presented better extraction efficiency and its parameters were optimized for determination of triazines in water samples by the SPE/LC-UV method (SPE/high performance liquid chromatography with UV-vis detection). According to the figures of merit evaluated, the proposed SPE/LC-UV method presented linearity in the concentration range of 0.5-50 ng.mL-1 and absolute recovery of 75 to 105%, with precision demonstrated by the coefficient of variation lower than 15%. The limit of quantification of the method was 0.5 ng.mL-1 for all the analytes. Thus, it was possible to develop new low-cost monolithic phases with chemical and mechanical resistance and physicochemical characteristics suitable for use as extractive phase in the miniaturized technique of preparation of DPX samples, as well as SPE. The developed phases were evaluated for the determination of triazines in water samples with adequate selectivity and sensitivity. Based on the results, the developed phases present themselves as promising alternative to the commercial extractive phases. / Os polímeros monolíticos podem ser definidos como polímeros contínuos altamente porosos, sintetizados in situ em um molde. Esses materiais têm sido empregados em aplicações cromatográficas devido a combinação de alta área superficial com excelentes propriedades de permeabilidade e transporte de massa. Nesse trabalho, polímeros monolíticos a base de estireno e divinilbenzeno foram sintetizados por iniciação térmica, via polimerização em massa na presença de diferentes diluentes; e via polimerização em emulsão de alta fase interna, na presença e na ausência de tolueno como diluente. Os monolitos produzidos via polimerização em massa, que foram sintetizados na presença das misturas binárias tetrahidrofurano/decanol e tolueno/decanol como diluentes de polimerização na proporção 15:85 (v/v) apresentaram resistência mecânica para serem aplicados como fases extratoras. Ambas as formulações produziram polímeros com característica macroporosa e a mistura tetrahidrofurano/decanol apresentou canais maiores, resultando em menor resistência à vazão, desta forma este foi utilizado como fase extratora para técnica de preparo de amostras baseada em dispositivo de extração sortiva em ponteira (DPX) aplicado à determinação de triazinas em amostras de água. Nas condições otimizadas a recuperação absoluta para as triazinas variou de 28 a 64%. Para os monolitos produzidos via polimerização em emulsão de alta fase interna, o efeito do solvente é mais significativo para o aumento da área superficial e do volume e diâmetro médio de poros do que o efeito da redução desses pelo aumento da velocidade de agitação. Com isso o monolito preparado na presença de tolueno na velocidade de 3000 rpm obteve maior área superficial e maior volume e diâmetro de poro, resultando em menor resistência à vazão e sua superfície foi modificada com polipirrol. Quando submetidos ao processo de extração empregando dispositivos de extração em fase sólida (SPE), o monolito recoberto com filmes de PPY, apresentou maior eficiência de extração sendo então seus parâmetros otimizados para determinação de triazinas em amostras de água pelo método SPE/LC-UV (SPE/cromatografia líquida de alta eficiência com detecção UV-vis). Segundo as figuras de mérito avaliadas o método SPE/LC-UV proposto, apresentou linearidade na faixa de concentração de 0,5-50 ng.mL-1 e recuperação absoluta de 75 a 105 %, com precisão demonstrada pelos coeficientes de variação menores que 15%. O limite de quantificação do método foi de 0,5 ng.mL-1 para todos os analitos. Assim sendo, foi possível desenvolver novas fases monolíticas de baixo custo com resistência química e mecânica e características físico-químicas adequadas para emprego como fase extratora em técnica miniaturizada de preparo de amostras DPX, assim como em SPE. As fases desenvolvidas foram avaliadas para determinação de triazinas em amostras de água apresentando seletividade e sensibilidade adequada. Com base nos resultados, as fases desenvolvidas apresentam se como promissora alternativa às fases extratoras comerciais.
283

Desempenho de reator UASB em escala plena no tratamento de esgoto sanitário e adensamento simultâneo de lodo ativado em excesso do pós-tratamento. / Full-scale UASB reactor performance in sanitary sewage treatment and simultaneous thickening of excess activated sludge of post-treatment.

Bruno Sidnei da Silva 30 July 2018 (has links)
Este trabalho de pesquisa teve por objetivo avaliar o efeito do descarte de lodo aeróbio no desempenho do reator UASB. Em paralelo, foi verificado o efeito dessa operação na qualidade do efluente final da ETE, no desempenho operacional da unidade de pós-tratamento e nas características do biogás produzido no reator UASB. De modo geral, não houve impacto negativo no processo de digestão anaeróbia em termos de DQO filtrada no efluente, que foi semelhante quando o afluente era composto essencialmente de esgoto bruto, na ordem de 60 a 80 mg/L. Por outro lado, os resultados indicaram uma tendência de redução da qualidade do efluente do reator UASB em termos de DQO total e sólidos em suspensão, quando da alimentação desse reator com excesso de lodo aeróbio. Em 2016, a concentração média de DQO total no efluente foi da ordem de 529 mg/L e a concentração média de SST foi na ordem de 672 mg/L quando o afluente do reator UASB era composto com excesso de lodo aeróbio, ao passo que, sem excesso de lodo aeróbio no afluente, a DQO total média no efluente foi de 269 mg/L e a concentração média de SST foi de 349 mg/L. Porém, essa redução da qualidade pareceu estar relacionada a uma sobreposição de efeitos associado a presença de lodo aeróbio no afluente, e a sistemática adotada na estação para remoção de lodo anaeróbio do reator UASB. Quando não havia remoção de excesso de lodo anaeróbio de fundo do reator UASB, a qualidade do efluente se manteve durante a maior parte do tempo monitorado compatível com os períodos onde o afluente do reator UASB era composto essencialmente de esgoto bruto, indicando que o lodo de fundo, mais concentrado, exerce papel fundamental na retenção do lodo aeróbio na zona de digestão do reator UASB. Essa constatação se mostrou mais explícita quando as operações de descarte de excesso de lodo aeróbio e remoção de lodo anaeróbio do reator UASB ocorriam em períodos distintos. Nessa condição, a concentração média de DQO total no efluente foi de 254 mg/L e a concentração média de SST foi de 314 mg/L, ao passo que sem lodo aeróbio no afluente do reator UASB, a concentração média de DQO total no efluente foi de 191 mg/L e a concentração de SST foi de 258 mg/L. As características do biogás produzido variaram quando o sistema era alimentado com excesso de lodo aeróbio no afluente, apresentando, nessa condição, maior concentração de CO2 e menor concentração de H2S. Não houve, alteração da concentração média de metano quando da presença de excesso de lodo aeróbio no afluente. Outro aspecto observado foi a falta de correlação entre os parâmetros DQO removida e produção volumétrica de biogás quando o afluente do reator UASB continha excesso de lodo aeróbio. Na ausência de excesso de lodo aeróbio no afluente, houve correlação entre essas variáveis, porém uma correlação fraca, na ordem de 0,40, que pode ser explicada por uma captação ineficaz do biogás produzido, devido a vazamentos pela linha de quebra-escuma do separador trifásico, e por perdas de metano dissolvido com o efluente. Com relação ao impacto na unidade de pós-tratamento, a baixa capacidade de remoção de lodo de excesso da ETE devido a dificuldades de ordem operacional e contratual, condicionaram a operação do sistema de lodo ativado com elevadas concentrações de sólidos em suspensão. Nessa condição, o sistema de aeração apresentou baixa eficiência de transferência de oxigênio para o licor misto, o que impactou negativamente no consumo de energia elétrica do processo de lodo ativado, aumentando o custo operacional da ETE. A qualidade do efluente final da ETE, de modo geral, não foi impactada pela operação de descarte de lodo aeróbio no reator UASB, tendo mantido durante a maior parte do tempo DQO média na ordem de 40 mg/L no efluente e concentração de sólidos em suspensão totais em média na ordem de 25 mg/L. A nitrificação e desnitrificação foi variável ao longo do período do estudo, sendo que o processo apresentou eficiência média de remoção de nitrogênio em torno de 66%. / The objective of this research was to evaluate the effect of aerobic sludge discard on UASB reactor performance. In parallel, the effect of this operation on the final effluent quality of the WWTP, the operational performance of the post-treatment plant and the characteristics of the biogas produced in the UASB reactor were verified. In general, there was no negative impact on the anaerobic digestion process in terms of dissolved COD in the effluent, which was similar when the influent was composed essentially of raw sewage, in the order of 60 to 80 mg / L. On the other hand, the results indicated a tendency to reduce the quality of the UASB reactor effluent in terms of total COD and suspended solids when feeding this reactor also with excess aerobic sludge. In 2016, the mean concentration COD in the effluent was of the order of 529 mg / L and the mean concentration SST was 672 mg / L when the UASB reactor inflow was composed of excess aerobic sludge, while, without excess of aerobic sludge in the influent, the mean COD in the effluent was 269 mg / L and the mean concentration of SST was 349 mg / L. However, this quality reduction seemed to be related to an overlap of effects associated with the presence of aerobic sludge in the influent, and the system adopted at the WWTP to remove anaerobic sludge from the UASB reactor. When there was no removal of excess anaerobic bottom sludge from the UASB reactor, the quality of the effluent remained for most of the monitored time consistent with the periods where the UASB reactor inflow was essentially composed of raw sewage, indicating that the sludge from deep, more concentrated, plays a fundamental role in the retention of aerobic sludge in the digestion zone of the UASB reactor. This finding was more explicit when the operations of excess aerobic sludge and anaerobic sludge removal from the UASB reactor occurred at different periods. In this condition, the mean COD concentration in the effluent was 254 mg / L and the mean SST concentration was 314 mg / L, whereas without aerobic sludge in the UASB reactor, the mean total COD concentration in the effluent was 191 mg / L and the concentration of SST was 258 mg / L. The characteristics of the biogas produced varied when the system was fed with excess of aerobic sludge in the influent presenting, in this condition, a higher concentration of CO2 and a lower concentration of H2S. There was, fortunately, no change in the average concentration of methane when there was an excess of aerobic sludge in the influent. Another important aspect observed was the lack of correlation between the COD removal parameters and volumetric biogas production when the UASB reactor inflow contained excess aerobic sludge. In the absence of excess aerobic sludge in the influent, there was a correlation between these variables, but a weak correlation, in the order of 0.40, which can be explained by an inefficient capture of the biogas produced, due to leaks by the three-phase separator, and for losses of methane dissolved with the effluent. Regarding the impact on the post-treatment unit, the low sludge removal capacity of the WWTP due to operational and contractual difficulties, conditioned the operation of the activated sludge system with high concentrations of suspended solids. In this condition, the aeration system presented low oxygen transfer efficiency for the mixed liquor, which negatively impacted the electric power consumption of the activated sludge process, increasing the operational cost of the WWTP. The final effluent quality, in general, was not affected by the aerobic sludge discharge operation in the UASB reactor, having maintained for the most part the average COD in the order of 40 mg / L in the effluent and the solids concentration in suspension on average in the order of 25 mg / L. Nitrification and denitrification were variable throughout the study period, with the average nitrogen removal efficiency around 66%.
284

Caracterização qualitativa do perfil volátil de vinhos espumantes brasileiros elaborados com um assemblage inovador submetidos a diferentes condições de segunda fermentação

Palma, Aline Schwertner January 2014 (has links)
Os vinhos espumantes elaborados pelo método Tradicional são elaborados, comumente, a partir das uvas Chardonnay, Pinot Noir, Chadonnay, Riesling, Viognier, Trebbiano e Pinot Noir e os componentes voláteis destes espumantes já têm merecido a atenção de diversos estudos científicos. Entretanto, vinhos espumantes produzidos a partir de outros varietais de uvas ainda não foram alvo de pesquisas científicas. A segunda fermentação ocorre dentro da garrafa e acaba por conferir uma maior complexidade aromática ao espumante produzido pelo método Tradicional, devido ao contato do vinho com as leveduras em meio redutor, por um determinado período de tempo. Isto acontece devido aos produtos secundários do metabolismo das leveduras, durante a conversão de açúcares em etanol e dióxido de carbono. Esta conversão depende dos nutrientes adicionados, chamados adjuvantes de fermentação, bem como da espécie de levedura utilizada, visto que cada levedura possui um metabolismo diferente para a utilização dos nutrientes e açúcares presentes no vinho base. Assim, objetivou-se, neste trabalho, caracterizar os componentes voláteis de vinhos espumantes de uma vinícola gaúcha, que emprega um assemblage inovador, empregando uvas Chadonnay, Riesling, Viognier, Trebbiano e Pinot Noir. Do assemblage deste vinho base utilizou-se, para segunda fermentação, duas espécies de leveduras comerciais: Saccharomyces cerevisiae e Saccharomyces bayanus. Para cada levedura utilizada na fermentação do vinho base, oito diferentes adjuvantes de fermentação foram empregados. A determinação dos compostos voláteis se deu através da técnica de microextração em fase sólida no modo headspace (HS-SPME) e cromatografia gasosa acoplada a detector de espectrometria demassa quadrupolar (GC/MS). Ao total, 25 compostos foram tentativamente identificados nos vinhos em estudo, sendo os compostos majoritários citados a seguir, com sua possível contribuição para o aroma destes vinhos: octanoato de etila (aroma de fruta), álcool isoamílico (aroma de banana), ácido octanoico (aroma de pimentão) e álcool feniletílico (aroma floral). O fenetil fenilacetato, um dos compostos minoritários tentativamente identificado em alguns dos vinhos, até então não reportado em vinho espumante, é associado a aroma frutado. Não foi possível distinguir subgrupos entre os 16 vinhos em estudo, provenientes de diferentes condições na segunda fermentação, quando as áreas cromatográficas dos compostos voláteis destes 16 vinhos foram submetidas a análise de cluster. Isto implica em que, nas condições experimentais deste estudo, não foi possível distinguir os voláteis dos vinhos fermentados (2ª fermentação) com S. cereviseae e os fermentados com S. bayanus. A mesma análise de cluster mostrou a subdivisão dos compostos voláteis dos 16 vinhos em dois grupos, os quais se distinguiram, provavelmente, devido aos diferentes adjuvantes nutricionais empregados: fosfato e Thiazote. Desta forma, através de análise qualitativa por HS-SPME-GC/MS, foi possível verificar a homogeneidade do perfil volátil dos 16 vinhos espumantes, obtidos a partir de diferentes adjuvantes de fermentação e duas espécies distintas de leveduras Saccharomyces sp, além de comparar os componentes voláteis presentes nestes espumantes com aqueles reportados na literatura para outros vinhos espumantes. / Sparkling wines elaborated by Traditional Method are usually produced by the grapes Chardonnay, Pinot Noir and Riesling, in which the volatile compounds of these sparkling wines have been calling attention to scientific studies. However, sparkling wines produced by other varietal grapes have not been a target of scientific research yet. The second fermentation occurs inside the bottle, in which confer a greater aromatic complexity to the sparkling wine produced by Traditional Method, due to the contact of it with lees in a reducing medium during a certain period of time. This happens due to secondary products of yeast metabolism, during the conversion of sugar in ethanol and carbon dioxide. This conversion depends on the nutrients added, called fermentation adjuvants, as the yeast used, since each one has a different metabolism for using this nutrients and sugars presented in the base wine. Thus, this work aims to characterize the volatile compounds of a south Brazilian winery, which use an innovative assemblage, using the grapes Chardonnay, Riesling, Viognier, Trebbiano and Pinot Noir. To the base wine, two different commercial yeasts were added: Saccharomyces cerevisiae and Saccharomyces bayanus to the performance of second fermentation. To each yeast used for fermenting the base wine, eight different fermentation adjuvants were used. The determination of volatile compounds were performed by Headspace solid-phase Microextraction (HS-SPME) and gas chromatography coupled to a mass quadrupole spectrometry (GC/MS). In total, 25 compounds were tentatively identified in the studied sparkling wines, being the majority listed as it follows, with their possible contribution to these sparkling wines aroma: ethyl octanoate (fruity), isoamyl alcohol (banana), octanoic acid (green pepper), and phenethyl alcohol (flower). Phenethyl phenylacetate, one of the minority compounds tentatively identified in some of the sparkling wines, is associated with fruity aroma. It was not possible to distinguish subgroups from different conditions during the second fermentation, when submitting the chromatographic areas of volatile compounds to cluster analysis. It implies that, under the experimental conditions of these study, it was not possible to differ the volatile compounds of the fermented (2nd fermentation) with S. cerevisiae and those which were fermented with S. bayanus. The same cluster analysis showed a subdivision of volatile compounds of the 16 wines in two groups, in which were probably distinguished due to the different nutritional adjuvants used: phosphate and Thiazote. Thus, throughout qualitative analysis by HS-SPME-GC/MS, it was possible to verify the homogeneity of volatile profile of the 16 sparkling wines, obtained by different fermentation adjuvants and two different yeast species of Saccharomyces sp, besides the comparison of volatile compounds presented in these sparkling wines with those others reported in the literature.
285

Caracterização de frutos de araçá (Psidium cattleianum Sabine): composição fenólica, atividade antioxidante e inibição de alfa-amilase e alfa-glicosidase / Characterization of araça fruits (Psidium cattleianum Sabine): phenolic composition, antioxidant activity and inhibition of alpha-amylase and alpha-glycosidase.

Pereira, Elisa dos Santos 22 February 2018 (has links)
Submitted by Gabriela Lopes (gmachadolopesufpel@gmail.com) on 2018-08-14T18:13:46Z No. of bitstreams: 1 DISSERTAÇÃO ELISA.pdf: 1165332 bytes, checksum: 954aaa7a7ee1f8fe3819ae5fb2f6f142 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-08-17T12:35:06Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO ELISA.pdf: 1165332 bytes, checksum: 954aaa7a7ee1f8fe3819ae5fb2f6f142 (MD5) / Made available in DSpace on 2018-08-17T12:35:06Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO ELISA.pdf: 1165332 bytes, checksum: 954aaa7a7ee1f8fe3819ae5fb2f6f142 (MD5) Previous issue date: 2018-02-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Dentre as frutas silvestres da mata Atlântica, o araçá destaca-se pela presença de compostos bioativos, com ação antiproliferativa, antimicrobiana, antienvelhecimento e antidiabética (pela inibição de alfa-amilase e alfaglicosidase). Entretanto, a quantificação e caracterização dos compostos presentes no araçá ainda não foram suficientemente elucidadas. Assim, foram identificados e quantificados compostos fenólicos presentes em diferentes extratos da polpa-casca e da semente de três genótipos de araçá, bem como suas atividades antioxidantes e seus potenciais de inibição de alfa-glicosidase e alfa-amilase. Os extratos obtidos foram fracionados por extração em fase sólida e os compostos presentes foram identificados e quantificados por análise cromatográfica. Não foram verificadas diferenças significativas na inibição enzimática entre os três genótipos, e nem mesmo entre polpa-casca e semente. Os compostos presentes na polpa-casca e na semente, independentemente do genótipo, inibiram a alfa-amilase e a alfa-glicosidase. Os compostos presentes na fração III (flavonoides) destacaram-se pela inibição da alfa-glicosidase e também da alfa-amilase, enquanto os compostos presentes na fração IV (antocianinas poliméricas) e no extrato não fracionado, destacaram-se pela inibição da alfa-glicosidase, com pouca inibição da alfaamilase. Nas frações estudadas, e também no extrato não fracionado, verificou-se maior concentração de ácido elágico, e menores concentrações de quercetina, cianidina-3-glicosídeo, malvidina-3-glicosídeo, e de ácidos vanílico, siríngico, p-cumárico e 4-hidroxibenzóico. Em conclusão, os extratos fenólicos de araçá inibiram alfa-amilase e alfa-glicosidase; os genótipos e a parte da fruta não influenciaram a inibição destas enzimas; os compostos presentes no extrato não fracionado e nas frações III e IV resultaram em maior inibição das enzimas estudadas. / Among the wild fruits of the Atlantic forest, araçá stands out for presenting bioactive compounds with antiproliferative, antimicrobial, anti-aging and antidiabetic action (by the inhibition of alpha-amylase and alpha-glucosidase). However, the quantification and characterization of the compounds present in the araçá have not been sufficiently elucidated. Thus, phenolic compounds present in different pulp-peel and seed extracts of three araçá genotypes were identified and quantified. In addition, their antioxidant activities and alphaglucosidase and alpha-amylase inhibition potentials were evaluated. The obtained extracts were fractionated by solid phase extraction and the phenolic compounds were identified and quantified by chromatographic analysis. No significant differences were observed for the enzymatic inhibition between the three genotypes, nor even between pulp-peel and seed. Alpha-amylase and alpha-glucosidase enzymes were inhibited by the compounds present in araçá pulp-peel and seed extracts regardless of genotype. Phenolic compounds present in fraction III (flavonoids) were distinguished by the inhibition of both alpha-glucosidase and alpha-amylase enzymes. However, phenolic compounds present in fraction IV (polymeric anthocyanins) and in the unfractionated extract, were distinguished by the inhibition of alpha-glucosidase, with slight inhibition of alpha-amylase. Ellagic acid was the compound found in higher amounts in the fractions and non-fractionated extract, while quercetin cyanidin-3-glycoside, malvidin-3-glycoside, and vanillic, syringic p-coumaric and 4-hidroxybenzoic acids were present in lower amounts. In conclusion, araçá phenolic extracts inhibited alpha-amylase and alpha-glucosidase; the genotype and the fruit part did not influence the inhibition of these enzymes; the compounds present in the unfractionated extract and fractions III and IV resulted in higher inhibition of the enzymes studie.
286

Desenvolvimento de metodologia analitica para determinação de codeina em plasma humano utilizando extração solido-liquido "on-line" acoplado ao HPLC-MS/MS / Analytical method development for determination of codeine in human plasma by on-line SPE-HPLC-MS/MS

Cruz, Alessandro de Carvalho 15 August 2018 (has links)
Orientador: Jose Pedrazzolli Junior / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T08:01:40Z (GMT). No. of bitstreams: 1 Cruz_AlessandrodeCarvalho_M.pdf: 6535924 bytes, checksum: 32e397fd65c63f6c293df90358e9eff3 (MD5) Previous issue date: 2010 / Resumo: Neste trabalho, a codeína foi determinada em plasma humano, através de metodologia analítica baseada no acoplamento da extração sólido-líquido "online" HPLC-MS/MS por electrospray positivo. O método foi desenvolvido visando a injeção direta de amostras plasmáticas sem prévio tratamento. O padrão interno utilizado foi o tramadol. O tempo total de análise foi de 3 min./amostra e devido ao sincronismo entre a corrida cromatográfica e a extração "on-line" automatizada o método possibilita a análise de mais de 400 amostras por dia. O uso de coluna monolítica (Chromolith Performance RP-18e, 100 mm x 4.6 mm) e extração em fase sólida automatizada (sistema Prospekt 2) demonstrou ser altamente eficiente em relação à resolução dos picos cromatográficos, tempo de retenção e pressão no interior da coluna cromatográfica. A curva de calibração foi definida com o intervalo de concentração de 5 à 200 ng/mL, atingindo boa linearidade. Excelentes resultados foram alcançados em relação à precisão e exatidão intra e inter-dia apresentando uma variação de 2.33 à 7.25% (CV%) e 2.35 à 9.97% (RE%), respectivamente. A metodologia analítica desenvolvida neste trabalho, baseada no acoplamento "on-line" SPE-HPLC-MS/MS apresentou boa seletividade, robustez, exatidão e precisão, bem como uma alta produtividade nas análises para determinação de codeína em plasma humano / Abstract: A specific LC-MS/MS method was developed and validated for automated determination of codeine in human plasma, using on-line solid-phase extraction (SPE) system coupled with positive ion electrospray ionization tandem mass spectrometry. Method allowed plasma direct injection onto cartridge without sample pre-treatment. Total analysis time per run was 3 min, allowing high-throughput for codeine determination. SPE on-line along monolithic column (Chromolith Performance RP-18e, 100 mm x 4.6 mm) demonstrated to be highly effective in terms of backpressure, separation speed and peak asymmetry. Calibration curves range was linear 5.0-200 ng/mL. Method showed an excellent intra-assay and inter-assay precision ranged from 2.33 to 7.25% (CV%) as well as great intra-assay and inter-assay accuracy, ranging from -2.35 to 9.97% (RE%). SPE-LC-MS/MS method provided selectivity, robustness, accuracy, precision and high-throughput to assess codeine pharmacokinetics in human plasma samples / Mestrado / Mestre em Farmacologia
287

Aplicações forenses do Probe Electrospray Ionization Mass Spectrometry com filme de polipirrol / Forensic aplications of Probe Electrospray Ionization Mass Spectrometry using polypyrrole films

Bernardo, Ricardo Alves 14 July 2017 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-08-09T19:01:05Z No. of bitstreams: 2 Dissertação - Ricardo Alves Bernardo - 2017.pdf: 2682606 bytes, checksum: f8d1278bd90c5b2d1870dc822ba29d59 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-08-10T13:37:03Z (GMT) No. of bitstreams: 2 Dissertação - Ricardo Alves Bernardo - 2017.pdf: 2682606 bytes, checksum: f8d1278bd90c5b2d1870dc822ba29d59 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-08-10T13:37:03Z (GMT). No. of bitstreams: 2 Dissertação - Ricardo Alves Bernardo - 2017.pdf: 2682606 bytes, checksum: f8d1278bd90c5b2d1870dc822ba29d59 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-07-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this study, we developed a solid phase microextraction (SPME) method to extract Cocaine, Lisergic Acid Diethylamide (LSD), Methamphetamine (MA) and [3,4 – Methylenedioxymethamphetamine] (MDMA), which allowed the direct analysis by MS in a Probe Electrospray Ionization Mass Spectrometry (PESI-MS). PPy fibers were deposited on a platinum wire. These fibers were subjected to drug extraction from biological fluids employing SPME principles. After that, the coated platinum wire was positioned in front of the MS and then a high voltage (HV) was applied on it. At the same time, methanol (formic acid 0,1%) was used to assist the analytes desorption, ionization, and detection. Parameters as number of cycles in electrochemical process, pH, temperature of extraction and matrix effect were evaluated. The coated PESI-MS method presented linearity in a concentration range from the limit of quantification (LOQ) to 500 ng.L-1 (ppb). The LOQ values ranged from 2 ng.L-1 to 10 ng.L-1. The interday precision presented values from 0.8 to 9.6% with accuracy ranging from -0.6 to 13.7%. The intraday precision obtained values varied from 1.7 to 10.8% with accuracy ranging from -2.4 to 14.0%. The absolute recovery was also evaluated and presented values from 97.6 to 114.0%. The proposed method is a promising alternative to fast sampling and analysis for avoiding laborious process, and for showing precision and accuracy according to the values proposed by ANVISA. / Para este trabalho foi desenvolvido um sistema SPME para extração e análise direta de Cocaína, Dietilamida do Ácido Lisérgico (LSD), [3,4 – Metilenodioximetanfetamina] (MDMA) e Metanfetamina (MA) por espectrometria de massas (MS) em uma fonte de ionização Probe Electrospray Ionization Mass Spectrometry (PESI-MS). Fibras de polipirrol (PPy) foram eletrodepositadas em um fio de platina, essas fibras foram submetidas à extração de drogas em fluidos biológicos empregando os princípios da SPME. Após a extração, o fio de platina contendo o revestimento de PPy foi posicionado na entrada do espectrômetro de massas, uma diferença de potencial (ddp) foi aplicada ao fio e com auxílio de uma solução de metanol (0,1% de ácido fórmico), observou-se a dessorção e detecção dos analitos previamente extraídos. Parâmetros como o número de ciclos de eletrodeposição e pH de extração foram avaliados. O método se mostrou linear na faixa de concentração do LOQ a 500 ng.L-1 (ppb). Os valores de LOQ variaram de 2 ng.L-1 a 10 ng.L-1. A precisão inter-dias do método foi avaliada e mostrou valores entre 0,8 a 9,6% com exatidão de -0,6 a 13,7%. A precisão intra-dias apresentou valores de 1,7 a 10,8% com exatidão de -2,4 a 14.0%. A recuperação do método também foi avaliada e apresentou valores de 97,6 a 114,0%. O método proposto apresenta-se como alternativa promissora para rápida extração e análise direta sem a realização de procedimentos dispendiosos e laboriosos, com precisão e exatidão dentro dos parâmetros propostos pela ANVISA.
288

Avaliação e desenvolvimento de um método para extração seletiva de cromo utilizando a luffa cylindrica como bioadsorvente / Evaluation and development of a method for selective extraction of chromium using luffa cylindrica as bioadsorbent

Sousa Neto, J. A. 20 April 2016 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2016-11-10T16:41:38Z No. of bitstreams: 2 Dissertação - José Alistor de Sousa Neto - 2016.pdf: 3187623 bytes, checksum: f99ac51c255f7fe2bb7330340f92c0e9 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2016-11-10T16:41:50Z (GMT) No. of bitstreams: 2 Dissertação - José Alistor de Sousa Neto - 2016.pdf: 3187623 bytes, checksum: f99ac51c255f7fe2bb7330340f92c0e9 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-11-10T16:41:50Z (GMT). No. of bitstreams: 2 Dissertação - José Alistor de Sousa Neto - 2016.pdf: 3187623 bytes, checksum: f99ac51c255f7fe2bb7330340f92c0e9 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-04-20 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / This work describes the development of a method in solid phase extraction for Cr (III) determination in food and environmental samples using Luffa cylindrica as bioadsorbent. In the first chapter, a characterization study to evaluate the use of Luffa cylindrica "in natura" as bioadsorbent for chromium ions (III and VI) adsorption in aqueous systems was conducted. Through characterization, specifically in relation to the determination of pH(PCZ), it became clear that the material has positively charged surface in solutions with pH below 6.0 and above this value, the surface is negatively charged. From this evidence, a study was conducted to evaluate the effect of pH solution on the chromium inorganic species adsorption has been noted that from pH = 4.0 it is possible to separate the chromium species (III and VI) and trivalent species exclusively adsorbed. Thus, we conducted several characterization tests such as Infrared Spectroscopy, X-rays Diffraction by the powder method, Elemental Analysis, Scanning Electron Microscopy and Energy Dispersive Spectroscopy to evaluate the physicochemical characteristics of Luffa cylindrica. The results of the kinetic study and the adsorption isotherms showed that the chromium III ions adsorption of Luffa cylindrica possibly occurs through an interaction of the chemical type. Furthermore, the parameters as stirring time and adsorbent mass were evaluated to obtain the best conditions of the adsorption process. Quantification of chromium before and after the adsorption process was performed by Flame Atomic Absorption Spectrometry. From the results, it was observed that requires 30 minutes to achieve sorption equilibrium and adsorption kinetics followed a pseudo-second-order. Study of possible interferences Ba2+, Co2+, Cu2+, Fe3+ and Mn2+ ions were performed in order to observe the selectivity of the material relative to the analyte of interest. The second chapter was developed a flow method of solid phase extraction for selective extraction and determination of Cr (III) ions in food and environmental samples. Multivariate techniques were used to evaluate the chemical variables and extraction flow system: adsorbent mass, separation flow rate, concentration and volume of eluent, through a 24factorial design. The results showed that the adsorbent mass and eluent volume was significantly influence in the flow system and has been used for optimization a Doehlert design of these variables indicating optimal values as 170 mg of adsorbent mass and 1348μL eluent (HNO3 1 mol L-1). The other variables, separation flow rate and eluent concentration were maintained at the values 2 mL min-1 and 1 mol L-1, respectively. The possible presence of interfering ions, Cu2+, Fe3+, Mn2+, Zn2+, Ca2+, Mg2+, Na+, K+, Cr6+ was studied in order to verify the selectivity of the analysis method. Through the calculated values for the interfering factor (IF) was determined good selectivity of the proposed method. The analytical performance was evaluated by the parameters, detection limit (LOD), quantification limit (LOQ), accuracy (D.P.R) and the values were 19.2 ug L-1; 63.99 ug L-1 and 0.19%, respectively, with the linear range of the method equal to 63.90 to 2000 ug L-1. Finally, the accuracy of the method was evaluated from analysis of water certificate reference material (APS-1071) and sediment (APS-1066). Recovery tests were performed on samples of water, energy and isotonic values having been found in the range from 87.60 to 107.35%. Keywords:Chromium, Luffa cylindrica, solid phase extraction. / Nesse trabalho é descrito o desenvolvimento de um método de extração em fase sólida para determinação de Cr(III) em amostras de interesse ambiental e alimentício utilizando Luffa cylindrica como bioadsorvente. No primeiro capítulo, um estudo de caracterização a fim de avaliar o uso da Luffa cylindrica “in natura” como bioadsorvente para adsorção de íons cromo III e VI em sistemas aquosos foi realizado. Através da caracterização, especificamente em relação à determinação do pH(pcz), ficou evidente que o material apresenta superfície carregada positivamente em soluções com pH abaixo de 6,0 e acima deste valor, a superfície se encontra carregada negativamente. A partir dessa evidência, foi realizado um estudo, a fim de avaliar o efeito do pH da solução na adsorção das espécies inorgânicas de cromo, tendo sido observado que a partir de pH= 4,0 é possível separar as espécies de cromo (III e VI), sendo a espécie trivalente exclusivamente adsorvida. Dessa forma, foram realizados diversos ensaios de caracterização tais como Espectroscopia de Infravermelho Médio, Difração de Raios-X pelo método do pó, Análise elementar, Microscopia Eletrônica de Varredura e Espectroscopia de Energia Dispersiva a fim de avaliar as características físico-químicas da Luffa cylindrica. Os resultados do estudo cinético e das isotermas de adsorção evidenciaram que a adsorção dos íons cromo III pela Luffa cylindrica “in natura”, possivelmente, ocorre através de uma interação do tipo química. Além disso, os parâmetros tempo de agitação e massa do adsorvente foram avaliados, visando obter as melhores condições do processo de adsorção. A quantificação do teor de cromo, antes e após o processo de adsorção, foi realizada por Espectrometria de Absorção Atômica por Chama. Através dos resultados, observou-se que são necessários 30 minutos para atingir o equilíbrio da sorção e que a adsorção obedece a uma cinética de pseudo-segunda-ordem. Estudo dos possíveis interferentes Ba2+, Co2+, Cu2+, Fe3+ e Mn2+ foram realizados a fim de se observar a seletividade do material em relação ao analito de interesse. No segundo capítulo foi desenvolvido um método de extração em fase sólida em fluxo para a extração seletiva e determinação de Cr(III) em amostras de interesse alimentício e ambiental. Técnicas multivariadas foram utilizadas para avaliar as variáveis químicas e de fluxo do sistema de extração: massa do adsorvente, vazão de separação, concentração e volume do eluente, através de um planejamento fatorial 24. Os resultados apontaram que as variáveis massa do adsorvente e volume do eluente influenciam significativamente no sistema em fluxo, tendo sido utilizado um planejamento Doehlert para otimização destas variáveis, indicando como valores ótimos 170 mg de adsorvente e 1348μL de eluente (HNO3 1 mol L-1). As demais variáveis, vazão de separação e concentração do eluente foram mantidas nos valores 2 mL min-1 e 1 mol L-1, respectivamente. A presença de possíveis íons interferentes, Cu2+, Fe3+, Mn2+, Zn2+, Ca2+, Mg2+, Na+, K+, Cr6+, foi estudada, a fim de verificar a seletividade do método de análise em fluxo. Através dos valores calculados para o fator de interferência (FI) foi determinada a boa seletividade do método proposto. O desempenho analítico foi avaliado por meio dos parâmetros, limite de detecção (LD), limite de quantificação (LQ), precisão (D.P.R) e os valores encontrados foram 19,2 μg L-1; 63,99 μg L-1 e 0,19%, respectivamente, sendo a faixa linear do método igual a 63,90 – 2000 μg L-1. Por fim, a exatidão do método foi avaliada a partir de análise de material certificado de referência de água (APS-1071) e sedimento (APS-1066). Testes de recuperação foram realizados em amostras de água, energético e isotônico, tendo sido encontrados valores na faixa de 87,60 – 107,35%. Palavras-chave: cromo, Luffa cylindrica, extração em fase sólida.
289

Desenvolvimento de um método de extração e pré-concentração em fluxo para determinação de cádmio em amostras de interesse alimentício utilizando a palha do café como adsorvente / Development of a method of extraction and pre-concentration in flow for determination of cadmium in samples of food interest using the coffee straw as adsorvent

Soares, Maria Dalva Americano 29 March 2017 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-05-15T20:03:44Z No. of bitstreams: 2 Dissertação - Maria Dalva Americano Soares - 2017.pdf: 2532503 bytes, checksum: 8d316e6aedc3fa70ec38c43e074d3bb3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-16T12:11:30Z (GMT) No. of bitstreams: 2 Dissertação - Maria Dalva Americano Soares - 2017.pdf: 2532503 bytes, checksum: 8d316e6aedc3fa70ec38c43e074d3bb3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-16T12:11:30Z (GMT). No. of bitstreams: 2 Dissertação - Maria Dalva Americano Soares - 2017.pdf: 2532503 bytes, checksum: 8d316e6aedc3fa70ec38c43e074d3bb3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-29 / The present work presents a study on the use of dry coffee straw and straw from sticky coffee, also known as "bark" of the coffee as adsorbent for metallic ions. Initially, the experiments were carried out in batch and the metal quantification before and after the adsorption experiments was done using Atomic Flame Absorption Spectrometry (FAAS). The adsorption of the ions Cd (II), was evaluated and the results indicated that the coffee straw dried in natura, presented an outstanding performance. The optimization parameters studied in the adsorption of the corresponding ion were the pH of the solution and time of contact, presenting the maximum adsorption occurrence in the pH value between 5 to 9 and better contact time starting from 60 minutes. The physical-chemical characterization of the material was done through the use of Infrared Spectroscopy, X-ray Dispersive Energy Analysis, X-Ray Diffraction Analysis, EDX Elemental Analysis and the zero load point determination. The adsorption kinetics best fit the pseudo-second order model and the adsorption isotherms developed with the objective of determining the maximum adsorptive capacity showed a better fit to the Langmuir model. From data obtained in the batch experiments, the dry coffee straw was used in the development of a solid phase extraction method for adsorption of cadmium. In order to evaluate the chemical and flow variables that possibly influence the system, the multivariate method was used. The variables studied were adsorbent mass, eluent concentration, eluent volume and pre-concentration flow, through a factorial design 24, indicating the eluent volume and pre-concentration flow as the significant variables, which were studied later by means of Doehlert planning. Thus, the best conditions for flow system operation were: adsorbent mass 25 mg, (HCl) eluent concentration 1.0 mol L-1, eluent volume 250 μL and pre-concentration flow 2.0 mL min-1. For the purpose of analyzing the selectivity of the method, a study of the possible interferences was done, based on the calculation of the interference factor (IF). The Cu+2, Fe+2, Mn+2, Zn+2, Ca+2, Mg+2, Na+1, K+1, Cr+3 ions were analyzed in different proportions. The pre-concentration factor was calculated as being equal to 20.4; Limit of detection (LD) 7,86 μg L-1, Limit of quantification (LQ) 26,20 μg L-1, precision (DPR) 0,11, linear range between 26,20 - 2000 μg L-1. The accuracy of the method was tested through the analysis of the certified water reference material (APS - 1071).The recovery tests were carried out on samples of cashew, pineapple, orange and guava juices, and the values found were ranged from 100,72 to 109,7%. The method developed was satisfactory for pre-concentration of Cd (II) ions, for the simplicity, efficiency, low cost. Also, the used adsorbent can be easily found in nature and it can be reused. / O presente trabalho apresenta um estudo sobre o uso da palha do café seca e palha do café melosa, também conhecida como “casca” do café como adsorvente para íons metálicos. Inicialmente os experimentos foram realizados em batelada e a quantificação dos metais antes e após os experimentos de adsorção foi feita utilizando Espectrometria de Absorção Atômica por Chama (FAAS). A adsorção dos íons Cd(II), foi avaliada e os resultados apontaram que a palha do café seca in natura, apresentou melhor desempenho. Os parâmetros de otimização estudados na adsorção do referido íon foram, pH da solução e tempo de contato, sendo que a máxima adsorção ocorre no valor de pH entre 5 a 9 e melhor tempo de contato a partir de 60 minutos. A caracterização físico-química do material foi feita através do uso da Espectroscopia de Infravermelho, Análise por Energia Dispersiva de Raios-X, Análise de Difração de Raios-X, Análise Elementar por EDX e determinação do ponto de carga zero. A cinética de adsorção ajusta melhor ao modelo de pseudo-segunda ordem e as isotermas de adsorção desenvolvidas com o objetivo de determinar a capacidade máxima adsortiva apresentou melhor ajuste ao modelo de Langmuir. A partir dos dados obtidos nos experimentos em batelada, a palha do café seca foi utilizada no desenvolvimento de um método de extração em fase sólida para adsorção de cadmio. Com objetivo de avaliar as variáveis químicas e de fluxo que possivelmente influenciam o sistema foi empregado o método multivariado. As variáveis estudadas foram, massa do adsorvente, concentração do eluente, volume do eluente e vazão de pré-concentração, por meio de um planejamento fatorial 24, apontando o volume do eluente e vazão de pré-concentração como sendo as variáveis significativas, sendo estudadas posteriormente por meio de um planejamento Doehlert. Assim, as melhores condições para o funcionamento do sistema em fluxo foram: massa do adsorvente 25 mg, concentração do eluente (HCl) 1,0 mol L-1, volume do eluente 250 μL e vazão de pré-concentração 2,0 mL min-1. A fim de analisar a seletividade do método, foi feito um estudo dos possíveis interferentes, a partir do cálculo do fator de interferência (FI). Tendo sido analisados os íons Cu+2, Fe+2, Mn+2, Zn+2, Ca+2, Mg+2, Na+1, K+1, Cr+3 em diferentes proporções. O fator de pré-concentração foi calculado como sendo igual a 20,4; Limite de detecção (LD) 7,86 μg L-1, Limite de quantificação (LQ) 26,20 μg L-1, precisão (DPR) 0,11, faixa linear entre 26,20 - 2000 μg L-1. A exatidão do método foi testada através da análise do material certificado de referência de água (APS – 1071). Os testes de recuperação foram desenvolvidos em amostras de sucos de caju, abacaxi, laranja e goiaba, sendo que os valores encontrados apresentaram-se na faixa de 100,72 – 109,7%. O método desenvolvido mostrou-se satisfatório para pré-concentração de íons Cd(II), pela simplicidade, eficiência, baixo custo e o adsorvente utilizado ser encontrado na natureza com facilidade bem como o seu reaproveitamento.
290

\"Estudo da eficiência do tratamento de efluentes domésticos da cidade de Araraquara-SP na remoção de hormônios sexuais\" / \"Study of the efficiency of the treatment of domestic effluents of the city of Araraquara-SP in the removal of sexual hormones\"

Juliana Coutinho de Araujo 24 March 2006 (has links)
Nos últimos anos, a pesquisa ambiental tem se defrontado com a questão dos chamados disruptores endócrinos (EDCs). A estes compostos, tais como: produtos farmacêuticos, hormônios naturais e sintéticos, pesticidas, substâncias tensoativas, polímeros de baixa massa molecular e diversos outros contaminantes orgânicos presentes em efluentes municipais e industriais, atribui-se à capacidade de alterar o funcionamento do sistema endócrino. Estrogênios e progestogênios, naturais ou sintéticos, são excretados pela urina de mamíferos, e uma pequena porção nas fezes, e via efluentes de estações de tratamento de esgoto (ETE) entram em vias aquáticas, podendo causar alterações em organismos aquáticos, tais como feminização ou hermafroditismo. Neste contexto, no presente trabalho foi descrito uma metodologia analítica para a extração em fase sólida empregando cartucho C18, dos hormônios naturais, estrona (E1) e 17?-estradiol (E2), e dos hormônios sintéticos, levonorgestrel e 17?-etinilestradiol (EE2) (presentes em anticoncepcionais orais), a partir de uma matriz de esgoto sintético. Foram utilizados dois sistemas cromatográficos neste estudo, ambos de mesmo modelo (SLC-10A, Shimadzu), os quais consistiram em um injetor manual (seringa), com um volume de injeção ajustado para 20µL, e duas bombas modelo LC-10ADVP (Shimadzu). Foram utilizados dois tipos de detectores, um sistema DAD modelo SPD-M10AVP (Shimadzu) e um espectrofluorímetro modelo RF-551 versão 2.4 (Shimadzu). A separação foi feita em coluna C18 (250 X 4,6 mm, 5 µm) com um fluxo de 1 mL min-1. A condição ideal para separação foi o modo isocrático: 48/52 ACN:H2O. O comprimento de onda selecionado para quantificação no sistema de detecção DAD foi: 240nm para o levonorgestrel e 280nm para E1, E2 e EE2. No detector espectrofluorímetro, os comprimentos de onda selecionados para a excitação e emissão dos analitos E1, E2 e EE2 foram: 280nm e 306nm, respectivamente. Para se efetuar o estudo de recuperação, uma matriz simulando esgotos sanitários foi utilizada com o intuito de se ter uma amostra controle (testemunha) livre dos analitos de interesse, devido à dificuldade em se obter uma amostra de esgoto “real” livre destes hormônios. As amostras de esgoto sintético foram fortificadas em três níveis de concentração. Tomou-se 5 replicatas de 100,0mL de amostra testemunha (esgoto sintético) para cada nível de fortificação, estas amostras foram dopadas com os hormônios estudados. Após adaptações de metodologias descritas na literatura, a extração foi feita segundo o procedimento: condicionamento do cartucho (500mg/6mL) com 7mL de acetonitrila, 5mL de metanol e 5mL de água em uma razão de fluxo de 3mL min-1; percolagem de 250,0mL de amostras de esgoto bruto e efluentes tratados pela ETE-Araraquara com fluxo de 1mL min-1; secagem do cartucho por 1 hora a vácuo; eluição dos analitos com 6mL de acetonitrila com fluxo de 1mL min-1; secagem do extrato eluído em corrente de nitrogênio; reconstituição da amostra em 0,5mL de metanol. As amostras de esgoto sintético foram dopadas com os padrões estudados, para análise realizada no sistema DAD, a 0,250?g L-1 para levonorgestrel e 2,50?g L-1 para E1, E2 e EE2 (nível 1); 0,375 ?g L-1 para levonorgestrel e 3,75 ?g L-1 para E1, E2 e EE2 (nível 2); 0,500?g L-1 para levonorgestrel e 5,00?g L-1 para E1, E2 e EE2 (nível 3). Para análise realizada no sistema fluorescente, as amostras de esgoto sintético foram dopadas com os padrões estudados a 0,750?g L-1 para E1; 0,150?g L-1 para E2 e 0,250?g L-1 para EE2 (nível 1); 1,00 ?g L-1 para E1; 0,150?g L-1 para E2 e 0,200?g L-1 para EE2 (nível 2); 1,25?g L-1 para E1; 0,250?g L-1 para E2 e 0,300 ?g L-1 para EE2 (nível 3). Valores de recuperação entre 83-123% com coeficientes de variação menores do que 13,5% foram obtidos para todos os hormônios analisados pelos dois sistemas de detecção (DAD e Fluorescente). Esses dados demonstram a eficiência do método quanto à exatidão e precisão para os níveis de fortificação estudados. O método proposto foi utilizado para avaliar a presenças dos hormônios em afluentes (esgoto bruto) e efluentes da ETE-Araraquara. As amostras coletadas na ETE foram analisadas em triplicata. Foi identificado e quantificado o hormônio natural E2 (31ng L-1) em amostras obtidas antes do tratamento de esgoto. Não foram detectadas concentrações dos analitos em amostras obtidas após o tratamento. / In recent years environmental research has been faced with the issue of the endocrine disrupting chemicals (EDCs). Such compounds, such as: pharmaceutical products, natural and synthetic hormones, pesticides, tensive active substances, low mass molar polymers and many other organic contaminants that appear in municipal and industrial effluents, have the capacity of altering the manner in which the endocrine system works. Natural or synthetic estrogens and progestogens are excreted through the urine of mammals, and a small portion through faeces, and via effluents from sewage treatment plants (STP) flow into aquatic ducts, with the possibility of causing alterations in the aquatic organisms, such as feminization or hermaphroditism. Within this context, the present work describes an analytic methodology for solid phase extraction (SPE) using C18 cartridge of the natural hormones, estrone (E1) and 17?-estradiol (E2), and the synthetic hormones levonorgestrel and 17?-ethinylestradiol (EE2) (found in oral contraceptives) from a synthetic waste matrix. Two chromatographic systems were used in this study, both from the same model (SLC-10A, Shimadzu), a DAD system model SPD-M10AVP (Shimadzu) and a spectrofluorimeter model RF-551 type 2.4 (Shimadzu). Separation was performed in column C18 (250 X 4,6 mm, 5 ?m) with a flux of 1 mL min-1. The ideal separation condition was the isocratic mode: 48/52 ACN:H2O. To carry out the recuperation study, a matrix simulating sewers was used with the objective of having a control sample (witness) free of the samples under scrutiny of the difficulty in obtaining a “real” sewage sample free of these hormones. The samples of synthetic sewage were boosted in three levels of concentration. Recuperation values between 83-123% with variation coefficients lower than 13,5% were obtained for all studied hormones by both systems of detections (DAD and Fluorescent). These data demonstrate the efficiency of the method concerning the accuracy and precision for the fortification levels that were studied. The proposed method was used to assess the presence of hormones in inffluents (raw sewage) and effluents of Araraquara-STP. The natural hormone E2 (31ng L-1) was identified and quantified in samples obtained prior to sewage treatment. No concentrations of analytes in the samples were obtained after the treatment.

Page generated in 0.0521 seconds