• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 10
  • 8
  • Tagged with
  • 54
  • 54
  • 33
  • 24
  • 23
  • 15
  • 14
  • 13
  • 13
  • 12
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Método UFRGS de previsão de capacidade de carga em estacas : análise de provas de carga estáticas instrumentadas / UFRGS method for pile bearing capacity prediction : static instrumented load tests

Langone, Marcelo Júlio January 2012 (has links)
Recentemente foi desenvolvido na Universidade Federal do Rio Grande do Sul um método racional para previsão de capacidade de carga em fundações profundas. Denominado de método UFRGS, este procedimento considera conceitos de energias envolvidos durante o ensaio SPT. No presente trabalho, realizou-se estudo da precisão das estimativas fornecidas pela aplicação do método com intuito de compreender, averiguar, ajustar e validar seu uso na prática de engenharia. Para tal, foi gerado um banco de dados de provas de carga estáticas instrumentadas com base na bibliografia nacional e internacional, sendo este constituído de 25 casos em estacas metálicas, 42 em escavadas, 12 do tipo hélice contínua e 10 em prémoldadas. Considerando a resistência mobilizada por atrito lateral, ponta, resistência total e curvas de mobilização, foram gerados gráficos expressando os resultados obtidos pelo método e os resultados medidos nas provas de carga. Adicionalmente, apresenta-se uma comparação com resultados fornecidos por métodos consagrados de previsão de comportamento em estacas: os métodos de Aoki-Velloso, Décourt & Quaresma e interpretação teórica. De maneira geral, o método UFRGS apresentou subestimativas e baixa dispersão para o atrito lateral e uma superestimativa acompanhada de maior dispersão para a ponta das estacas. Da análise dos resultados, verifica-se que o método captura os mecanismos de mobilização de resistência desenvolvidos nas estacas, e reproduz resultados globais compatíveis com os métodos empregados na prática de engenharia. Além disso, apresenta destacada potencialidade haja vista à facilidade de melhoria dos resultados, que através da calibração da energia transferida pelo ensaio SPT, possibilita aplicação e compartilhamento entre diferentes práticas internacionais. Por fim, no âmbito de projeto, destaca-se que dentre todos os métodos empregados, o método estudado forneceu menor dispersão de atrito lateral. Em projetos que envolvem cálculos de risco e probabilidade de ruína, chama-se atenção de que melhorias discretas nos valores de dispersões geram ganho significativo na diminuição dos riscos. / Recently, a rational method for predicting the pile bearing capacity was developed at Federal University of Rio Grande do Sul in Brazil: the so called method UFRGS which considers the concepts of soil dynamics and principles of energy conservation in the interpretation of SPT test results. The present work analyses the accuracy of predicted bearing capacity values with the aim of understanding, verifying, and validating its application in engineering practice. Thus a database of static and instrumented load tests was built from national and international case studies; the data is composed by 25 load tests executed on steel piles, 42 on drilled piles, 12 on continuous flight auger piles and 10 on precast piles. The mobilized contributions of skin friction, tip resistance, and load mobilization curves of each pile were evaluated and compared to actual predictions using the results from UFRGS method. Furthermore, a series of charts were prepared showing comparisons between results of the UFRGS method and those obtained from other predictive methods of pile bearing capacity adopted in the Brazilian engineering practice: Aoki-Velloso and Décourt & Quaresma, as well as a method based on theoretical interpretation of pile response. In general, the UFRGS method underestimated the results for skin friction while slightly overestimate tip resistance and the scatter of predictions is generally lower than other methods. From these analyses, it was possible to conclude that the method captures the mobilization mechanisms developed around piles, and gives predictions which are in the same range as those produced by other methods adopted in Brazil. The UFRGS method has marked potential for being used in design practice given the fact that predictions can be improved by calibrating the SPT energy, which would allow to refine the predictions according to different practices of used worldwide. Finally it is important to stress that the UFRGS method showed the littlest scatter for skin friction assessment which may provide to be significant in risk analysis type of approach.
12

Método UFRGS de previsão de capacidade de carga em estacas : análise de provas de carga estáticas instrumentadas / UFRGS method for pile bearing capacity prediction : static instrumented load tests

Langone, Marcelo Júlio January 2012 (has links)
Recentemente foi desenvolvido na Universidade Federal do Rio Grande do Sul um método racional para previsão de capacidade de carga em fundações profundas. Denominado de método UFRGS, este procedimento considera conceitos de energias envolvidos durante o ensaio SPT. No presente trabalho, realizou-se estudo da precisão das estimativas fornecidas pela aplicação do método com intuito de compreender, averiguar, ajustar e validar seu uso na prática de engenharia. Para tal, foi gerado um banco de dados de provas de carga estáticas instrumentadas com base na bibliografia nacional e internacional, sendo este constituído de 25 casos em estacas metálicas, 42 em escavadas, 12 do tipo hélice contínua e 10 em prémoldadas. Considerando a resistência mobilizada por atrito lateral, ponta, resistência total e curvas de mobilização, foram gerados gráficos expressando os resultados obtidos pelo método e os resultados medidos nas provas de carga. Adicionalmente, apresenta-se uma comparação com resultados fornecidos por métodos consagrados de previsão de comportamento em estacas: os métodos de Aoki-Velloso, Décourt & Quaresma e interpretação teórica. De maneira geral, o método UFRGS apresentou subestimativas e baixa dispersão para o atrito lateral e uma superestimativa acompanhada de maior dispersão para a ponta das estacas. Da análise dos resultados, verifica-se que o método captura os mecanismos de mobilização de resistência desenvolvidos nas estacas, e reproduz resultados globais compatíveis com os métodos empregados na prática de engenharia. Além disso, apresenta destacada potencialidade haja vista à facilidade de melhoria dos resultados, que através da calibração da energia transferida pelo ensaio SPT, possibilita aplicação e compartilhamento entre diferentes práticas internacionais. Por fim, no âmbito de projeto, destaca-se que dentre todos os métodos empregados, o método estudado forneceu menor dispersão de atrito lateral. Em projetos que envolvem cálculos de risco e probabilidade de ruína, chama-se atenção de que melhorias discretas nos valores de dispersões geram ganho significativo na diminuição dos riscos. / Recently, a rational method for predicting the pile bearing capacity was developed at Federal University of Rio Grande do Sul in Brazil: the so called method UFRGS which considers the concepts of soil dynamics and principles of energy conservation in the interpretation of SPT test results. The present work analyses the accuracy of predicted bearing capacity values with the aim of understanding, verifying, and validating its application in engineering practice. Thus a database of static and instrumented load tests was built from national and international case studies; the data is composed by 25 load tests executed on steel piles, 42 on drilled piles, 12 on continuous flight auger piles and 10 on precast piles. The mobilized contributions of skin friction, tip resistance, and load mobilization curves of each pile were evaluated and compared to actual predictions using the results from UFRGS method. Furthermore, a series of charts were prepared showing comparisons between results of the UFRGS method and those obtained from other predictive methods of pile bearing capacity adopted in the Brazilian engineering practice: Aoki-Velloso and Décourt & Quaresma, as well as a method based on theoretical interpretation of pile response. In general, the UFRGS method underestimated the results for skin friction while slightly overestimate tip resistance and the scatter of predictions is generally lower than other methods. From these analyses, it was possible to conclude that the method captures the mobilization mechanisms developed around piles, and gives predictions which are in the same range as those produced by other methods adopted in Brazil. The UFRGS method has marked potential for being used in design practice given the fact that predictions can be improved by calibrating the SPT energy, which would allow to refine the predictions according to different practices of used worldwide. Finally it is important to stress that the UFRGS method showed the littlest scatter for skin friction assessment which may provide to be significant in risk analysis type of approach.
13

Análise de provas de carga estática em estacas pré-moldadas cravadas na cidade de Curitiba e região metropolitana / Analysis of static loading tests in concrete drive pile carried out in Curitiba city and metropolitan area

Ana Paula Fontana Vianna 29 June 2000 (has links)
Nesta dissertação são analisadas 34 provas de carga estática realizadas em estacas pré-moldadas de concreto, cravadas em diferentes locais da cidade de Curitiba e região metropolitana, sendo a maioria delas na Formação Guabirotuba. Três métodos de previsão da capacidade foram analisados: Aoki – Velloso (1975), Décourt – Quaresma (1978) e Amaral (1982, 1999). Para cada método foram propostos fatores de correção global e/ou parcial que tornam o valor da capacidade de carga mais próximo do valor da carga última obtida pelo critério de Van der Veen (1953). Com base em quatro provas de carga conduzidas até a ruptura, estudou-se a aplicabilidade do método de Van der Veen (1953) e determinou-se um critério para avaliar a extrapolação da curva carga x recalque em ensaios encerrados sem atingir a ruptura. Finalmente fez-se uma análise dos recalques comparando-se os valores medidos com os calculados, para três níveis de carregamento, além da comparação das curvas carga x recalque ajustadas com as experimentais. / This thesis presents the analysis of 34 static loading tests in concrete drive pile, located at different places of the Curitiba city and metropolitan area, in Guabirotuba Formation. Three methods of the bearing capacity prediction were assessed: Aoki – Velloso (1975), Décourt – Quaresma (1978) and Amaral (1982, 1999). For each method is proposed global correction factors and/or partial that turned the bearing capacity value close to the ultimate load obtained for the Van der Veen criteria (1953). Based on four static loading test carried out to failure, the applicability of the Van der Veen criteria was assessed and was determined a rule to evaluate the extrapolation of the load - settlement curve in tests stopped before of the failure. Finally, it was made an analysis of the settlements, where it was compared the observed values and the predicted values, for three loading level, and also a comparison between the experimental load-settlement curve and the predicted load-settlement curve.
14

Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soils

Márcio Benvenutti 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
15

Dynamic load modeling in power system analysis

Gracia, Joseph Roger 28 July 2010 (has links)
The objective of this thesis is to examine the effect of dynamic induction machine modeling and polynomial static load modeling on the stability of electric power systems and to compare the results with those obtained using constant impedance or constant current load models. A least-squares curve fit algorithm is developed and used in modeling static and quasi-static loads as a function of the bus voltage. A dynamic model for the induction machine which accounts for rotor electrical and mechanical transients is incorporated into the solution algorithm. A test system is analyzed under a variety of loading conditions. The effect of the induction motor .load inertia constants on the system stability are also examined. Plots of load bus voltages during the transient stability period are included. / Master of Science
16

Mecanismos de transferência de carga em estacas escavadas em solos arenosos através de provas de carga instrumentadas

Sestrem, Liamara Paglia January 2018 (has links)
A experiência acumulada quanto à análise do comportamento de fundações, em relação aos diversos perfis de solos, vem confirmando a necessidade de realizar ensaios em verdadeira grandeza para avaliação de desempenho desses elementos. Aplicação de metodologias empíricas e semi-empíricas, limitadas à prática construtiva regional e às condições específicas que contemplaram o seu estabelecimento, resultam em incertezas nos métodos de previsão e dispersão entre valores de capacidade de carga medidos e previstos. Com base nessas evidências, os ensaios de prova de carga representam a técnica mais comumente empregada para previsão e avaliação da capacidade de suporte em estacas. Como resultado, obtém-se uma curva carga versus deslocamento a partir de um carregamento estático no topo do elemento. Quando executadas em estacas instrumentadas ao longo do fuste, permitem avaliar a mobilização (transferência) de resistências (cargas) ao longo da profundidade e dos carregamentos. Alternativamente, o uso de células expansivas bidirecionais, comumente denominadas de “O-cell”, vem crescendo em nível internacional e confirmando seu potencial de aplicação, embasado por vantagens que incluem a ausência de um sistema de reação e a obtenção de forma direta da resistência de ponta e atrito lateral durante os carregamentos. No intuito de contribuir para uma melhor compreensão dos mecanismos de transferência de carga envolvidos em ensaios estáticos, o presente estudo comparou resultados dessas duas metodologias através de três de ensaios estáticos convencionais e um bidirecional realizados em duas estacas escavadas de grande diâmetro em areia. A distribuição dos carregamentos medidos em função do deslocamento em termos de carga total e de atrito lateral ao longo desses quatro ensaios caracterizou-se por resultados similares. Pequenas diferenças foram observadas entre o ensaio de topo e bidirecional executados em um mesmo elemento de fundação e estão possivelmente associadas aos diferentes níveis de deformação obtidos com as duas técnicas. As condições de limpeza e integridade da ponta em estacas moldadas in loco estão associadas a incertezas ainda que os procedimentos usuais de controle e limpeza tenham sido executados. Divergências entre a parcela de contribuição de ponta ao longo dos ensaios avaliados podem estar associadas a esses fatores e a pequenas variações da geometria descritas em detalhes no trabalho. Deformações medidas pelos strain gages instalados ao longo do fuste da estaca permitiram avançar no entendimento dos mecanismos de transferência de carga existentes durante os carregamentos impostos. Os resultados indicam que o atrito começa a ser mobilizado desde os primeiros incrementos de carga e permanece se desenvolvendo com o aumento das deformações que não são constantes ao longo da profundidade. O comportamento medido ao longo do fuste varia em função do nível de confinamento e ainda da densidade relativa do solo subjacente. Os resultados permitem concluir também que ainda que existam esforços residuais atuantes, sua ordem de grandeza não reflete mudanças importantes no comportamento de elementos de fundação moldados in loco. / The gained experience in foundations behavior analysis on different soil profiles confirms the need to perform tests on full-scale elements to evaluate pile performance. Application of empirical and semi-empirical methodologies, limited to the regional constructive practice and the specific conditions that led to its establishment, result in uncertainties in the prediction and dispersion methods between measured and predicted load capacity values. Based on these evidences, the load tests represent the most commonly used technique for predicting and evaluating pile capacity. As a result, a load versus displacement curve is obtained from a static load at the top of the element. When carried out in piles instrumented along the shaft, it is possible to evaluate the mobilization (transfer) of resistances (loads) along the depth and the loads. Alternatively, the use of bidirectional expansive cells, commonly referred to as "O-cell", has been growing internationally, which confirms its potential, based on advantages that include the absence of a reaction system and obtaining the toe resistance and lateral friction directly during loading. In order to contribute to a better understanding of the load transfer mechanisms involved in static loading tests, the present study compared the results of these two methodologies through three conventional and one bidirectional load tests carried out on two large diameter bored piles. The distribution of loadings measured as a function of the displacement in terms of total load and lateral friction over these four tests was characterized by similar results. Small differences were observed between conventional top-down and bidirectional tests performed on the same foundation member and are possibly associated with the different deformation levels obtained with the two techniques. Cleaning conditions and pile toe integrity in bored piles are associated with uncertainties even though the usual control and cleaning procedures have been performed. Divergences between the contributions of the pile toe resistance along the evaluated tests may be associated with these factors and small variations of the geometry. Deformations measured by the strain gages installed along the pile shaft allowed improving the understanding of the load transfer mechanisms during the loading procedures. The results indicate that shaft friction begins to be mobilized since the first load increments and continues to increase with the strains, which are not linear along the pile shaft. The behavior measured along the shaft is a function of vertical effective stress and relative density. The results also show that although there are active residual stresses, their magnitude does not reflect important changes in the behavior of bored piles.
17

Análise da influência de diferentes tipos de cargas no desempenho da proteção anti-ilhamento de geradores distribuídos / Analysis of influence of different types of loads on the performance of anti-islanding protection of distributed generators

Carvalho, Marcelo Moreira de 04 September 2014 (has links)
A conexão de geradores distribuídos nas redes de subtransmissão e de distribuição de energia elétrica se mostra cada vez mais crescente devido aos inúmeros benefícios técnicos e econômicos alcançados com essa tecnologia. No entanto, há importantes implicações técnicas que precisam ser analisadas antes que um gerador distribuído seja conectado em paralelo ao sistema elétrico. Um aspecto a ser analisado, e que é comum entre as concessionárias de energia elétrica é a adequação da proteção anti-ilhamento, a qual tem a função de detectar essa condição e, automaticamente, desconectar os geradores distribuídos, dentro de um tempo pré-determinado, e assim mantê-los até que o fornecimento de energia seja restabelecido. Neste contexto, este trabalho analisará o desempenho dos relés de proteção anti-ilhamento em face de diferentes tipos de cargas que acabam afetando o tempo de detecção do ilhamento. Com isso, pretende-se obter subsídios para que os ajustes desses relés sejam calculados de forma eficiente. Os relés estudados são o relé de sub/sobrefrequência e o relé de taxa de variação da frequência, e o gerador distribuído é do tipo síncrono equipado com controle de tensão. As análises mostraram que no instante em que ocorre um ilhamento os fatores que mais influenciam no desempenho dos relés de proteção anti-ilhamento são as condições de carga e geração, tempo de detecção estabelecido, tipo do relé adotado, ajuste do mesmo e modelo de carga utilizado. / The connection of distributed generators to power subtransmission and distribution networks has been increasing recently due to the technical and economic benefits that such technology can provide. However, there are important technical issues that need to be carefully analyzed before a distributed generator is connected to electrical systems. One issue to be analyzed, which is common sense among utility companies, is the anti-islanding protection, whose main goal is to detect unintentional islanding and, automatically, disconnect the distributed generators within a required time-interval. In this context, this work will analyze the performance of anti-islanding protection relays in face of different load types. With this study, one intend to get support for adjusting these relays efficiently. The relays studied in this work are the under/over frequency and the rate of change of frequency relays, and the distributed generator is a synchronous machine equipped with an automatic voltage regulator. The analyzes showed that the moment a islanding occurs the most important factors influencing the performance of relays anti-islanding protection are the conditions of load and generation, detection time set, type and relay setting adopted and load model.
18

Metodologia para a determinação da eficiência do ensaio SPT através de prova de carga estática sobre o amostrador padrão / Methodology to determine the SPT efficiency through static load test over the sampler

Neves, Luis Fernando de Seixas 23 March 2004 (has links)
O ensaio de simples reconhecimento de solos (SPT) é a ferramenta de investigação de solos mais utilizada no mundo. Devido ao grande número de parâmetros que influenciam os seus resultados, a medida de sua eficiência passa a ser indispensável à transposição de experiências entre as práticas desenvolvidas em diferentes locais. Infelizmente, a medida da eficiência através da instrumentação do impacto do martelo é economicamente inviável para a maioria das empresas de sondagem no Brasil. Este trabalho apresenta uma metodologia para a determinação da eficiência do SPT baseada no princípio de Hamilton e na realização de prova de carga estática sobre o amostrador, que pode ser uma alternativa para sanar esta situação. / The standard penetration test (SPT) is the most used soil investigation tool in the world. Due to the great number of variables that influences its results, the measurement of the efficiency becomes imperative to the transposition of experiences between developed practices in different places. Unfortunately, the measurement of the efficiency through the instrumentation of the hammer impact is economically inpracticable to most of the soil investigation firms in Brazil. This work presents a methodology to determinate the SPT efficiency based on the Hamilton\'s principle and on the execution of static load test over the sampler, what seems to be a good alternative to end this situation.
19

Análise da influência de diferentes tipos de cargas no desempenho da proteção anti-ilhamento de geradores distribuídos / Analysis of influence of different types of loads on the performance of anti-islanding protection of distributed generators

Marcelo Moreira de Carvalho 04 September 2014 (has links)
A conexão de geradores distribuídos nas redes de subtransmissão e de distribuição de energia elétrica se mostra cada vez mais crescente devido aos inúmeros benefícios técnicos e econômicos alcançados com essa tecnologia. No entanto, há importantes implicações técnicas que precisam ser analisadas antes que um gerador distribuído seja conectado em paralelo ao sistema elétrico. Um aspecto a ser analisado, e que é comum entre as concessionárias de energia elétrica é a adequação da proteção anti-ilhamento, a qual tem a função de detectar essa condição e, automaticamente, desconectar os geradores distribuídos, dentro de um tempo pré-determinado, e assim mantê-los até que o fornecimento de energia seja restabelecido. Neste contexto, este trabalho analisará o desempenho dos relés de proteção anti-ilhamento em face de diferentes tipos de cargas que acabam afetando o tempo de detecção do ilhamento. Com isso, pretende-se obter subsídios para que os ajustes desses relés sejam calculados de forma eficiente. Os relés estudados são o relé de sub/sobrefrequência e o relé de taxa de variação da frequência, e o gerador distribuído é do tipo síncrono equipado com controle de tensão. As análises mostraram que no instante em que ocorre um ilhamento os fatores que mais influenciam no desempenho dos relés de proteção anti-ilhamento são as condições de carga e geração, tempo de detecção estabelecido, tipo do relé adotado, ajuste do mesmo e modelo de carga utilizado. / The connection of distributed generators to power subtransmission and distribution networks has been increasing recently due to the technical and economic benefits that such technology can provide. However, there are important technical issues that need to be carefully analyzed before a distributed generator is connected to electrical systems. One issue to be analyzed, which is common sense among utility companies, is the anti-islanding protection, whose main goal is to detect unintentional islanding and, automatically, disconnect the distributed generators within a required time-interval. In this context, this work will analyze the performance of anti-islanding protection relays in face of different load types. With this study, one intend to get support for adjusting these relays efficiently. The relays studied in this work are the under/over frequency and the rate of change of frequency relays, and the distributed generator is a synchronous machine equipped with an automatic voltage regulator. The analyzes showed that the moment a islanding occurs the most important factors influencing the performance of relays anti-islanding protection are the conditions of load and generation, detection time set, type and relay setting adopted and load model.
20

Full-Scale Testing of Blast-Induced Liquefaction Downdrag on Driven Piles in Sand

Kevan, Luke Ian 01 July 2017 (has links)
Deep foundations such as driven piles are often used to bypass liquefiable layers of soil and bear on more competent strata. When liquefaction occurs, the skin friction around the deep foundation goes to zero in the liquefiable layer. As the pore pressures dissipate, the soil settles. As the soil settles, negative skin friction develops owing to the downward movement of the soil surrounding the pile. To investigate the magnitude of the skin friction along the shaft three driven piles, an H-pile, a closed end pipe pile, and a concrete square pile, were instrumented and used to measure soil induced load at a site near Turrell, Arkansas following blast-induced liquefaction. Measurements were made of the load in the pile, the settlement of the ground and the settlement of piles in each case. Estimates of side friction and end-bearing resistance were obtained from Pile Driving Analyzer (PDA) measurements during driving and embedded O-cell type testing. The H-pile was driven to a depth of 94 feet, the pipe pile 74 feet, and the concrete square pile 72 feet below the ground surface to investigate the influence of pile depth in response to liquefaction. All three piles penetrated the liquefied layer and tipped out in denser sand. The soil surrounding the piles settled 2.5 inches for the H-pile, 2.8 inches for the pipe pile and 3.3 inches for the concrete square pile. The piles themselves settled 0.28 inches for the H-pile, 0.32 inches for the pipe pile, and 0.28 inches for the concrete square pile. During reconsolidation, the skin friction of the liquefied layer was 43% for the H-pile, 41% for the pipe pile, and 49% for the concrete square pile. Due to the magnitude of load felt in the piles from these tests the assumption of 50% skin friction developing in the liquefied zone is reasonable. Reduced side friction in the liquefied zone led to full mobilization of skin friction in the non-liquefied soil, and partial mobilization of end bearing capacity. The neutral plane, defined as the depth where the settlement of the soil equals the settlement of the pile, was outside of the liquefied zone in each scenario. The neutral plane method that uses mobilized end bearing measured during blasting to calculate settlement of the pile post liquefaction proved to be accurate for these three piles.

Page generated in 0.0739 seconds