• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 9
  • 9
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A quantitative evaluation of surgical fabric permeability - the effects of pressure, dwell time and challenge fluid on the strike through process

Flaherty, Andrew L. 05 1900 (has links)
No description available.
2

Revisão sistemática sobre o uso de aventais cirúrgicos, conforme o material de confecção, no controle da contaminação/infecção do sítio cirúrgico / Systematic revision about the use of surgical gowns, according to the confection material, in the control contamination/surgical site infection

Burgatti, Juliane Cristina 27 August 2007 (has links)
O avental cirúrgico, um dos principais componentes de barreira antimicrobiana, é confeccionado com materiais de tecido e não-tecido. A Sociedade Norte-Americana de Enfermeiros do Centro Cirúrgico - AORN e a Norma Européia - EN 13795-3 recomendam que os aventais cirúrgicos devam prover uma barreira apropriada contra microrganismos, sangue e outros fluidos corpóreos (seco ou molhado). Tais recomendações, no entanto, não definem o que consideram como \"barreira apropriada\". O que ainda não foi comprovado, porém, é se o uso de materiais de não-tecido realmente interfere, isoladamente, tanto na contaminação da ferida operatória, quanto na ocorrência de ISC. O presente estudo teve como objetivo verificar se há evidências científicas, pela revisão sistemática de literatura, que fundamentem a prática do uso de aventais em cirurgias, conforme seu material de confecção. Foram considerados para a revisão sistemática apenas estudos básicos de intervenção, que investigaram a contaminação e ou a infecção do sítio cirúrgico com uso de aventais cirúrgicos reutilizáveis e ou de uso-único, utilizando como população pessoas submetidas a cirurgias, em situações reais ou simuladas, em qualquer período, sem limitação de idioma. Para localizar os estudos, utilizou-se a estratégia: P (pacientes) = pacientes cirúrgicos - surgical patients, I (intervenção) = roupa hospitalar ou roupa de proteção – clothing / protective clothing, C (comparação) = uso-único ou reutilizável - single-use or reusable, O (desfecho) = contaminação ou infecção da ferida operatória – surgical wound infection/contamination. A busca dos estudos orientou-se pelas bases de dados eletrônicas: LILACS, CINAHL, EMBASE, COCHRANE, PubMed/MEDLINE, pesquisa manual na revista da Sociedade Brasileira de Enfermeiros de Centro Cirúrgico (SOBECC) e referências dos estudos incluídos. Os dados analisados foram apresentados em três fases: Fase 1: Caracterização do processo de seleção dos estudos; Fase 2: Caracterização dos estudos incluídos; Fase 3: Avaliação da evidência dos estudos incluídos, a partir de duas escalas de qualidade, sendo uma delas a de Jadad e outra a de Controle de Infecção Cirúrgica (EQCIC), adaptada de Nobre e Bernardo. A amostra desta revisão sistemática constituiu-se de 12 estudos, sendo que apenas um deles investigou o avental isoladamente. Os demais investigaram principalmente os campos cirúrgicos juntamente com os aventais. Constata-se, com isso, dificuldade de isolar o objeto de intervenção de outros inúmeros fatores que podem interferir nos desfechos, em estudos desta natureza. Dois estudos (E1, E2) obtiveram forte evidência de recomendação, concluindo pela não diferença de contaminação e infecção do sítio cirúrgico entre aventais e campos de tecido e não-tecido. Devido à ausência de estudos semelhantes não houve a possibilidade de realizar a metanálise. A verificação isolada de aventais cirúrgicos depende de mais pesquisas bem controladas e delineadas. A contribuição desta investigação para a implementação de prática baseada em evidências mostrou-se relevante não somente para responder especificamente à questão da pesquisa, mas também para identificar qualidade, lacunas, falhas e recomendar aspectos a serem considerados nas próximas pesquisas desta natureza / The surgical gown, one of the main components of the antimicrobial barrier, is confectioned with woven and non-woven materials. The American Operating Room Nursing - AORN and The European Norm - EN 13795-3 recommend that the surgical gowns should provide an appropriate barrier against microorganisms, blood and other organic fluids (dry or wet). These recommendations, however, do not define, yet, what to consider an \"appropriate barrier\".. What has not been proved yet is if the use of non-woven materials influence, in an isolated way, both the contamination of an operation wound, and the occurrence of ISC. It was the objective of this present study to investigate if there is scientific evidence, by means of systematic revision, that founded the practice of use of gowns in surgery, according to its material of confections. Only basic studies of intervention that investigated the contamination and or surgical site infection with the use of surgical gowns reusable or single-use were considered in the systematic revision, which used as population people who underwent surgery, in real or simulated situations, in any period, without idiom limitation. To locate the studies, we used the PICO strategy: P (patients): surgical patients, I (intervention) = clothing/protective clothing, C (comparison) = single-use or reusable, O (outcome) = contamination or surgical wound infection. The search of studies was guided by the following electronic data bases: LILACS, PubMed/MEDLINE, EMBASE, COCHRANE, CINAHL, manual research in the magazine of Brazilian Society Operating Room Nursing (SOBECC) and references of included studies. The data analyses were shown in three phases: Phase 1: characterization of process of select studies; Phase 2: characterization of included studies; Phase 3: evaluation of the evidence found in the included studies, using two quality scales, being one this The Jadad and other Surgical Infection Control (EQCIC), adapted from Nobre and Bernardo. The sample of this systematic revision comprises 12 studies, being only one of them analyzed only gowns. The remainder investigated mainly the surgical fields together with the gowns. We can see thereby the difficulty in isolating the object of intervention from other countless factors that can influence outcomes, in studies of this nature. Two studies (E1, E2) found strong evidence of recommendation, concluding that there is no difference in terms of contamination and surgical wound infection between woven and non-woven gowns and drapes. Due to the absence of similar studies it is not possible to do some metanalysis. The isolated verification of surgical gowns needs more well controlled and delineated research. The contribution of this investigation to the implementation of practices based on evidences in showed relevant not only to answer specifically the question of research, but also to identify quality, gaps and flaws and recommend aspects to be considered in future research of this nature
3

Revisão sistemática sobre o uso de aventais cirúrgicos, conforme o material de confecção, no controle da contaminação/infecção do sítio cirúrgico / Systematic revision about the use of surgical gowns, according to the confection material, in the control contamination/surgical site infection

Juliane Cristina Burgatti 27 August 2007 (has links)
O avental cirúrgico, um dos principais componentes de barreira antimicrobiana, é confeccionado com materiais de tecido e não-tecido. A Sociedade Norte-Americana de Enfermeiros do Centro Cirúrgico - AORN e a Norma Européia - EN 13795-3 recomendam que os aventais cirúrgicos devam prover uma barreira apropriada contra microrganismos, sangue e outros fluidos corpóreos (seco ou molhado). Tais recomendações, no entanto, não definem o que consideram como \"barreira apropriada\". O que ainda não foi comprovado, porém, é se o uso de materiais de não-tecido realmente interfere, isoladamente, tanto na contaminação da ferida operatória, quanto na ocorrência de ISC. O presente estudo teve como objetivo verificar se há evidências científicas, pela revisão sistemática de literatura, que fundamentem a prática do uso de aventais em cirurgias, conforme seu material de confecção. Foram considerados para a revisão sistemática apenas estudos básicos de intervenção, que investigaram a contaminação e ou a infecção do sítio cirúrgico com uso de aventais cirúrgicos reutilizáveis e ou de uso-único, utilizando como população pessoas submetidas a cirurgias, em situações reais ou simuladas, em qualquer período, sem limitação de idioma. Para localizar os estudos, utilizou-se a estratégia: P (pacientes) = pacientes cirúrgicos - surgical patients, I (intervenção) = roupa hospitalar ou roupa de proteção – clothing / protective clothing, C (comparação) = uso-único ou reutilizável - single-use or reusable, O (desfecho) = contaminação ou infecção da ferida operatória – surgical wound infection/contamination. A busca dos estudos orientou-se pelas bases de dados eletrônicas: LILACS, CINAHL, EMBASE, COCHRANE, PubMed/MEDLINE, pesquisa manual na revista da Sociedade Brasileira de Enfermeiros de Centro Cirúrgico (SOBECC) e referências dos estudos incluídos. Os dados analisados foram apresentados em três fases: Fase 1: Caracterização do processo de seleção dos estudos; Fase 2: Caracterização dos estudos incluídos; Fase 3: Avaliação da evidência dos estudos incluídos, a partir de duas escalas de qualidade, sendo uma delas a de Jadad e outra a de Controle de Infecção Cirúrgica (EQCIC), adaptada de Nobre e Bernardo. A amostra desta revisão sistemática constituiu-se de 12 estudos, sendo que apenas um deles investigou o avental isoladamente. Os demais investigaram principalmente os campos cirúrgicos juntamente com os aventais. Constata-se, com isso, dificuldade de isolar o objeto de intervenção de outros inúmeros fatores que podem interferir nos desfechos, em estudos desta natureza. Dois estudos (E1, E2) obtiveram forte evidência de recomendação, concluindo pela não diferença de contaminação e infecção do sítio cirúrgico entre aventais e campos de tecido e não-tecido. Devido à ausência de estudos semelhantes não houve a possibilidade de realizar a metanálise. A verificação isolada de aventais cirúrgicos depende de mais pesquisas bem controladas e delineadas. A contribuição desta investigação para a implementação de prática baseada em evidências mostrou-se relevante não somente para responder especificamente à questão da pesquisa, mas também para identificar qualidade, lacunas, falhas e recomendar aspectos a serem considerados nas próximas pesquisas desta natureza / The surgical gown, one of the main components of the antimicrobial barrier, is confectioned with woven and non-woven materials. The American Operating Room Nursing - AORN and The European Norm - EN 13795-3 recommend that the surgical gowns should provide an appropriate barrier against microorganisms, blood and other organic fluids (dry or wet). These recommendations, however, do not define, yet, what to consider an \"appropriate barrier\".. What has not been proved yet is if the use of non-woven materials influence, in an isolated way, both the contamination of an operation wound, and the occurrence of ISC. It was the objective of this present study to investigate if there is scientific evidence, by means of systematic revision, that founded the practice of use of gowns in surgery, according to its material of confections. Only basic studies of intervention that investigated the contamination and or surgical site infection with the use of surgical gowns reusable or single-use were considered in the systematic revision, which used as population people who underwent surgery, in real or simulated situations, in any period, without idiom limitation. To locate the studies, we used the PICO strategy: P (patients): surgical patients, I (intervention) = clothing/protective clothing, C (comparison) = single-use or reusable, O (outcome) = contamination or surgical wound infection. The search of studies was guided by the following electronic data bases: LILACS, PubMed/MEDLINE, EMBASE, COCHRANE, CINAHL, manual research in the magazine of Brazilian Society Operating Room Nursing (SOBECC) and references of included studies. The data analyses were shown in three phases: Phase 1: characterization of process of select studies; Phase 2: characterization of included studies; Phase 3: evaluation of the evidence found in the included studies, using two quality scales, being one this The Jadad and other Surgical Infection Control (EQCIC), adapted from Nobre and Bernardo. The sample of this systematic revision comprises 12 studies, being only one of them analyzed only gowns. The remainder investigated mainly the surgical fields together with the gowns. We can see thereby the difficulty in isolating the object of intervention from other countless factors that can influence outcomes, in studies of this nature. Two studies (E1, E2) found strong evidence of recommendation, concluding that there is no difference in terms of contamination and surgical wound infection between woven and non-woven gowns and drapes. Due to the absence of similar studies it is not possible to do some metanalysis. The isolated verification of surgical gowns needs more well controlled and delineated research. The contribution of this investigation to the implementation of practices based on evidences in showed relevant not only to answer specifically the question of research, but also to identify quality, gaps and flaws and recommend aspects to be considered in future research of this nature
4

Evaluierung von OP-Textilien nach hygienischen, ökonomischen und ökologischen Kriterien / Evaluation of Operating Room Textiles according to Hygienic Economic and Ecological Criteria

Günther, Edeltraud, Hoppe, Holger, Jatzwauk, Lutz, Lehmann, Beata, Mucha, Helmut, Pietsch, Kathrin 18 September 2005 (has links) (PDF)
Der zielgerichtete Einsatz innovativer Operationstextilien ist eine wichtige Maßnahme zur perioperativen Infektionsprophylaxe. Operationsmäntel und -abdecktücher sind den Bereichen Mehrweg- und Einwegprodukte zuzuordnen, mit deren Nutzung ein entsprechender Ressourcenverbrauch sowie Schadstoffbelastung verbunden sind. Den Anwendern ist die Auswahl kostengünstiger und umweltfreundlicher Produkte, gleiche Funktionalität vorausgesetzt, zurzeit nicht möglich, da Operationstextilien bislang in dieser Ganzheitlichkeit noch nicht betrachtet und untersucht worden sind. Das interdisziplinäre Verbundvorhaben befasst sich deshalb mit der ganzheitlichen Evaluierung innovativer Operationstextilien unter realen Praxisbedingungen nach funktionalen, hygienischen sowie ökologisch und ökonomischen Aspekten im Verlaufe ihres Lebenszyklus. Das Verbundvorhaben wird in 4 Teilprojekten mit folgenden wissenschaftlichen Zielstellungen bearbeitet: - Entwicklung einer Methode zur ganzheitlichen Evaluierung von OP-Textilien - Bewertung der Barrierewirkung von OP-Textilien hinsichtlich ihrer Struktur-Eigenschafts-Beziehungen in Abhängigkeit von den Nutzungszyklen - Bewertung der Barrierewirkung von OP-Textilien hinsichtlich ihrer Qualität und Konformität in Abhängigkeit von den Nutzungszyklen - Mikrobiologische und physikalische Untersuchungen zum Einfluss der Struktur von Operationstextilien auf deren Dampfsterilisation unter Praxisbedingungen - Ökonomische und ökologische Aspekte beim Erhalt der Barrierewirkung - Verknüpfung der funktionalen, ökonomischen und ökologischen Bewertungen zur Erstellung von Entscheidungsinstrumenten für den indikationsgerechten Einsatz von OP-Textilien. / The specific use of innovative O.R. textiles is an important measure for the perioperative infection prophylaxis. Surgical gowns and drapes are available as single-use and re-usable products. Their use is connected with the corresponding consumption of resources and environmental pollution. At present, the selection of cost-saving and environmental-friendly products with a high level of protection is not possible, because O.R. textiles have not been integral investigated up to now. Hence, the interdisciplinary project is dealing with the holistic evaluation of O.R. textiles according to hygienic, ecological and economic criteria during their life cycle influenced by real conditions in practice. The integrated project consists of 4 sub projects with the following scientific objectives: - developing of a method for the holistic evaluation of O.R. textiles - assessment of the barrier effect of the O.R. textiles in reference to the structure-properties-relations depending on the use cycles - assessment of the barrier effect of the O.R. textiles in reference to the quality and conformity depending on the use cycle - microbiological and physical investigations regarding to the influence of the structure of the O.R. textiles on the steam sterilisation in practice - ecological and economic assessment of reprocessing and preservation of the barrier function depending on the use cycles.
5

Targeted partial finishing of barrier textiles with microparticles, and their effects on barrier properties and comfort

Kuhr, Marlena, Aibibu, Dilbar, Cherif, Chokri 09 October 2019 (has links)
Woven barrier fabrics for filtration and operating room textiles feature permeable pore channels between yarn interlocking points (mesopores), which create an increased risk of penetration by contaminated fluids and particles. These pore channels can be reduced in size by high-density weaving. This, however, results in deteriorated drapability and performance characteristics. To meet the requirements made on the barrier effect without impairing the physiological properties of the textile, fluid-tight and particle-tight woven fabrics with adjustable porosity are being developed. This research aim could be realized by the targeted and partial application of microparticles into the mesopores. There, they form a meshed structure in the pores, whose size is thus reduced without them being entirely obstructed. The simultaneous retention of the micropores (pores between the individual filaments) in the woven fabric guarantees preservation of the physiological characteristics of the textile. The efficiency of the finishing was examined by an extensive physiological and physical characterization of the woven fabrics before and after particle application. Regarding the test method used to monitor the barrier effect and the channel paths, a test device was modified to simulate the demands of later, practical use.
6

Methods for a permanent binding of functionalized micro-particle on polyester fabric for the improvement of the barrier effect

Kuhr, Marlena, Synytska, Alla, Bellmann, C., Aibibu, Dilbar, Cherif, Chokri 09 October 2019 (has links)
Polyethylene terephthalate multifilament fabrics used as filtration and operating room textiles possess through-thickness pore channels at the yarn intersections (mesopores). These pore channels pose a risk for the penetration of contaminated fluids and particles. The size of pore channels may be reduced by high-density weaving. However, this leads to reduced drapability and thus to degraded application properties of the fabric. To satisfy the requirements without impeding the physiological properties of the textile, fluid- and particle-tight fabrics are developed. This was realized by partial immobilization of functionalized micro particles into the meso-pores. A reduction of the pore size without complete pore-closure is achieved by establishing a net-like particle structure in the meso-pores. To match the requirements of intensive use, permanent particle-bonding to the fiber surface is necessary. This can be achieved by suitable polyethylene terephthalate fabric surface-modification, dependent on the particle functionalization. The investigations have shown that functionalized particles establish a very good inter particle bonding as well as to the fiber surface. An increased permanent bonding can be realized by a modification of the fabric surface which is tuned to the functionalization of the particle.
7

Charakterisierung, Modellierung und Optimierung der Barriereeigenschaften von OP-Textilien

Aibibu, Dilibaier 26 October 2006 (has links) (PDF)
Durch die systematischen und umfangreichen experimentellen Untersuchungen werden in dieser Arbeit erstmalig die Einflüsse der textiltechnologischen Parameter des Garn- und Gewebebildungsprozesses auf die Porenstruktur und die davon abhängige Barrierewirkung von marktrelevanten OP-Geweben grundlegend analysiert. Daraus resultiert der Schwerpunkt der Arbeit – die Erarbeitung von Modellen – mit denen die Zusammenhänge zwischen strukturbedingten Einflussgrößen von Geweben und deren Barrierewirkung gegenüber kontaminierten Flüssigkeiten charakterisiert werden kann. Aufgrund des maßgeblichen Einflusses der Mikrostruktur auf das makroskopische Materialverhalten wird ein hierarchisches Strukturmodell eingeführt, welches zwischen der Makro-, Meso- und Mikroebene unterscheidet. Diese Strukturebenen erfassen die Gewebestruktur in unterschiedlichen Modellierungsniveaus. Die Systematisierungskriterien Garnfeinheit, Gewebebindung und Fadendichte beschreiben die Mesoebene. Die Filamentfeinheit und der Filamentquerschnitt sind wesentliche Kenngröße der Mikroebene. Das anhand des Darcy-Gesetzes entwickelte Modell für die Beschreibung der Mesoebene ist anschaulicher und beinhaltet den Einfluss der Bindung und der Formänderungen der Filamentgarne bei der Gewebeherstellung. Bei der Analyse der Porenstruktur werden mit Hilfe der optischen Methode – Bildanalyse – systematische Untersuchungen an der Morphologie des Gewebes durchgeführt, die bisher noch nicht realisierbar waren. Hier besteht die Möglichkeit, in das Gewebeinnere „hineinzusehen“ und sich nicht nur auf die funktionalen Parameter zu beschränken. Um die Transportmechanismen von Mikroorganismen unter praxisrelevanten Bedingungen zu simulieren, wird ein Verfahren entwickelt. Die Entwicklung erstreckt sich auf die Simulation des Drucks und der Reibung sowie die Simulation der im OP-Saal vorhandenen Flüssigkeiten mit synthetischem Blut und mit Mikrokugeln kontaminiertem Wasser. Das Verfahren ergänzt die optischen Untersuchungen und trägt zur Interpretation bei. Die qualitativen mikroskopischen Untersuchungen durch die Betrachtung der Gewebeoberfläche und -querschnitte unterstützen die Lokalisierung der Partikel im und auf dem Gewebe. Sie liefern interessante Aussagen und Informationen über die Durchgangsmechanismen von partikelbeladenen Flüssigkeiten durch das Gewebe. Der experimentelle Teil befasst sich mit der kritischen Auswahl und Charakterisierung repräsentativer OP-Textilien. Die wissenschaftlichen Fragestellungen werden an 6 repräsentativen PES-Filamentgeweben von 23 marktrelevanten PES-Filamentgeweben für OP-Textilien untersucht und beantwortet. Diese werden hinsichtlich des Einflusses der textiltechnologischen Parameter – Filamentfeinheit, -querschnitt, und Filamentgarnfeinheit sowie der webtechnischen Parameter – auf die strukturbedingte Barrierewirkung anhand der entwickelten Modelle und des Penetrationsversuches evaluiert. Auf diesen Ergebnissen aufbauend werden die Ansätze für die Optimierung der Gewebestruktur hinsichtlich der Barrierewirkung erstellt. Durch die Kombination von feinen Garnen mit hoher Fadendichte unter Ausnutzung von technologischen Möglichkeiten werden Mustergewebe aus PES-Mikrofilamentgarnen mit hoher Barrierewirkung hergestellt. Die experimentelle Untersuchung der am Institut für Textil- und Bekleidungstechnik entwickelten Mustergewebe und die theoretischen Modellrechnungen bestätigen das vorhandene textiltechnische Potenzial zur Optimierung von Mikrofilamentgeweben, d. h., einer weiteren Erhöhung der Widerstandsfähigkeit gegenüber partikelbeladenen Flüssigkeiten. Die Porenweiten in der Mesoebene können wirkungsvoll durch den Einsatz von feinen Filamentgarnen und das Erreichen der hohen Fadendichten in beiden Fadensystemen um die 50 % reduziert werden. Im Vergleich zu marktrelevanten OP-Geweben weisen die Mustergewebe eine erheblich hohe Barrierewirkung gegenüber synthetischem Blut und mit Mikrokugeln kontaminiertem Wasser auf. Diese Arbeit zur grundlegenden Analyse der strukturbedingten Barriereeigenschaften bietet Grundlagen für künftig notwendige Entscheidungen in der Produktentwicklung, Produktion, Produktnormung sowie Produktevaluierung. Sie kann in unterschiedliche Richtung fortgesetzt werden und die Optimierung flüssigkeits- und partikeldichter Gewebe im Gesundheitswesen, Reinraumtechnik im Speziellen oder von Schutztextilien im Allgemeinen, aber auch die Konkretisierung und Übertragung der Modellansätze betreffen.
8

Evaluierung von OP-Textilien nach hygienischen, ökonomischen und ökologischen Kriterien: Methodische Herangehensweise bei der Evaluierung unter realen praktischen Bedingungen

Günther, Edeltraud, Hoppe, Holger, Jatzwauk, Lutz, Lehmann, Beata, Mucha, Helmut, Pietsch, Kathrin 18 September 2005 (has links)
Der zielgerichtete Einsatz innovativer Operationstextilien ist eine wichtige Maßnahme zur perioperativen Infektionsprophylaxe. Operationsmäntel und -abdecktücher sind den Bereichen Mehrweg- und Einwegprodukte zuzuordnen, mit deren Nutzung ein entsprechender Ressourcenverbrauch sowie Schadstoffbelastung verbunden sind. Den Anwendern ist die Auswahl kostengünstiger und umweltfreundlicher Produkte, gleiche Funktionalität vorausgesetzt, zurzeit nicht möglich, da Operationstextilien bislang in dieser Ganzheitlichkeit noch nicht betrachtet und untersucht worden sind. Das interdisziplinäre Verbundvorhaben befasst sich deshalb mit der ganzheitlichen Evaluierung innovativer Operationstextilien unter realen Praxisbedingungen nach funktionalen, hygienischen sowie ökologisch und ökonomischen Aspekten im Verlaufe ihres Lebenszyklus. Das Verbundvorhaben wird in 4 Teilprojekten mit folgenden wissenschaftlichen Zielstellungen bearbeitet: - Entwicklung einer Methode zur ganzheitlichen Evaluierung von OP-Textilien - Bewertung der Barrierewirkung von OP-Textilien hinsichtlich ihrer Struktur-Eigenschafts-Beziehungen in Abhängigkeit von den Nutzungszyklen - Bewertung der Barrierewirkung von OP-Textilien hinsichtlich ihrer Qualität und Konformität in Abhängigkeit von den Nutzungszyklen - Mikrobiologische und physikalische Untersuchungen zum Einfluss der Struktur von Operationstextilien auf deren Dampfsterilisation unter Praxisbedingungen - Ökonomische und ökologische Aspekte beim Erhalt der Barrierewirkung - Verknüpfung der funktionalen, ökonomischen und ökologischen Bewertungen zur Erstellung von Entscheidungsinstrumenten für den indikationsgerechten Einsatz von OP-Textilien. / The specific use of innovative O.R. textiles is an important measure for the perioperative infection prophylaxis. Surgical gowns and drapes are available as single-use and re-usable products. Their use is connected with the corresponding consumption of resources and environmental pollution. At present, the selection of cost-saving and environmental-friendly products with a high level of protection is not possible, because O.R. textiles have not been integral investigated up to now. Hence, the interdisciplinary project is dealing with the holistic evaluation of O.R. textiles according to hygienic, ecological and economic criteria during their life cycle influenced by real conditions in practice. The integrated project consists of 4 sub projects with the following scientific objectives: - developing of a method for the holistic evaluation of O.R. textiles - assessment of the barrier effect of the O.R. textiles in reference to the structure-properties-relations depending on the use cycles - assessment of the barrier effect of the O.R. textiles in reference to the quality and conformity depending on the use cycle - microbiological and physical investigations regarding to the influence of the structure of the O.R. textiles on the steam sterilisation in practice - ecological and economic assessment of reprocessing and preservation of the barrier function depending on the use cycles.
9

Charakterisierung, Modellierung und Optimierung der Barriereeigenschaften von OP-Textilien

Aibibu, Dilibaier 02 November 2005 (has links)
Durch die systematischen und umfangreichen experimentellen Untersuchungen werden in dieser Arbeit erstmalig die Einflüsse der textiltechnologischen Parameter des Garn- und Gewebebildungsprozesses auf die Porenstruktur und die davon abhängige Barrierewirkung von marktrelevanten OP-Geweben grundlegend analysiert. Daraus resultiert der Schwerpunkt der Arbeit – die Erarbeitung von Modellen – mit denen die Zusammenhänge zwischen strukturbedingten Einflussgrößen von Geweben und deren Barrierewirkung gegenüber kontaminierten Flüssigkeiten charakterisiert werden kann. Aufgrund des maßgeblichen Einflusses der Mikrostruktur auf das makroskopische Materialverhalten wird ein hierarchisches Strukturmodell eingeführt, welches zwischen der Makro-, Meso- und Mikroebene unterscheidet. Diese Strukturebenen erfassen die Gewebestruktur in unterschiedlichen Modellierungsniveaus. Die Systematisierungskriterien Garnfeinheit, Gewebebindung und Fadendichte beschreiben die Mesoebene. Die Filamentfeinheit und der Filamentquerschnitt sind wesentliche Kenngröße der Mikroebene. Das anhand des Darcy-Gesetzes entwickelte Modell für die Beschreibung der Mesoebene ist anschaulicher und beinhaltet den Einfluss der Bindung und der Formänderungen der Filamentgarne bei der Gewebeherstellung. Bei der Analyse der Porenstruktur werden mit Hilfe der optischen Methode – Bildanalyse – systematische Untersuchungen an der Morphologie des Gewebes durchgeführt, die bisher noch nicht realisierbar waren. Hier besteht die Möglichkeit, in das Gewebeinnere „hineinzusehen“ und sich nicht nur auf die funktionalen Parameter zu beschränken. Um die Transportmechanismen von Mikroorganismen unter praxisrelevanten Bedingungen zu simulieren, wird ein Verfahren entwickelt. Die Entwicklung erstreckt sich auf die Simulation des Drucks und der Reibung sowie die Simulation der im OP-Saal vorhandenen Flüssigkeiten mit synthetischem Blut und mit Mikrokugeln kontaminiertem Wasser. Das Verfahren ergänzt die optischen Untersuchungen und trägt zur Interpretation bei. Die qualitativen mikroskopischen Untersuchungen durch die Betrachtung der Gewebeoberfläche und -querschnitte unterstützen die Lokalisierung der Partikel im und auf dem Gewebe. Sie liefern interessante Aussagen und Informationen über die Durchgangsmechanismen von partikelbeladenen Flüssigkeiten durch das Gewebe. Der experimentelle Teil befasst sich mit der kritischen Auswahl und Charakterisierung repräsentativer OP-Textilien. Die wissenschaftlichen Fragestellungen werden an 6 repräsentativen PES-Filamentgeweben von 23 marktrelevanten PES-Filamentgeweben für OP-Textilien untersucht und beantwortet. Diese werden hinsichtlich des Einflusses der textiltechnologischen Parameter – Filamentfeinheit, -querschnitt, und Filamentgarnfeinheit sowie der webtechnischen Parameter – auf die strukturbedingte Barrierewirkung anhand der entwickelten Modelle und des Penetrationsversuches evaluiert. Auf diesen Ergebnissen aufbauend werden die Ansätze für die Optimierung der Gewebestruktur hinsichtlich der Barrierewirkung erstellt. Durch die Kombination von feinen Garnen mit hoher Fadendichte unter Ausnutzung von technologischen Möglichkeiten werden Mustergewebe aus PES-Mikrofilamentgarnen mit hoher Barrierewirkung hergestellt. Die experimentelle Untersuchung der am Institut für Textil- und Bekleidungstechnik entwickelten Mustergewebe und die theoretischen Modellrechnungen bestätigen das vorhandene textiltechnische Potenzial zur Optimierung von Mikrofilamentgeweben, d. h., einer weiteren Erhöhung der Widerstandsfähigkeit gegenüber partikelbeladenen Flüssigkeiten. Die Porenweiten in der Mesoebene können wirkungsvoll durch den Einsatz von feinen Filamentgarnen und das Erreichen der hohen Fadendichten in beiden Fadensystemen um die 50 % reduziert werden. Im Vergleich zu marktrelevanten OP-Geweben weisen die Mustergewebe eine erheblich hohe Barrierewirkung gegenüber synthetischem Blut und mit Mikrokugeln kontaminiertem Wasser auf. Diese Arbeit zur grundlegenden Analyse der strukturbedingten Barriereeigenschaften bietet Grundlagen für künftig notwendige Entscheidungen in der Produktentwicklung, Produktion, Produktnormung sowie Produktevaluierung. Sie kann in unterschiedliche Richtung fortgesetzt werden und die Optimierung flüssigkeits- und partikeldichter Gewebe im Gesundheitswesen, Reinraumtechnik im Speziellen oder von Schutztextilien im Allgemeinen, aber auch die Konkretisierung und Übertragung der Modellansätze betreffen.

Page generated in 0.0596 seconds