• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 6
  • 6
  • 6
  • 6
  • 6
  • Tagged with
  • 39
  • 39
  • 39
  • 33
  • 32
  • 31
  • 30
  • 15
  • 14
  • 11
  • 11
  • 10
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Resistência de união regional de pinos de fibra de vidro fixados com cimentos resinosos experimentais contendo sal de ônio e diferentes aminas terciárias / Regional bond strength of fiber glass posts fixed with experimental resin cements containing onium salts and different tertiary amines

Leite, Thatiana de Vicente, 1988- 04 May 2013 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T21:20:40Z (GMT). No. of bitstreams: 1 Leite_ThatianadeVicente_M.pdf: 962489 bytes, checksum: 384dca92c91450403a7ee6a9653d3bef (MD5) Previous issue date: 2013 / Resumo: O objetivo deste trabalho foi avaliar, in vitro, a resistência de união (push-out) regional (terços cervical, médio e apical) de pinos de fibra de vidro (Reforpost #3, Ângelus Indústria de Produtos Odontológicos S/A, Londrina, PR) fixados com cimentos resinosos experimentais foto-ativados, contendo diferentes concentrações do sal hexafluorfosfato de difeniliodônio (DFI), variando as aminas terciárias entre EDAB e DMAEMA, e compará-los a um cimento resinoso disponível no mercado em sua versão dual e foto-ativável. Foram utilizadas 80 raízes de incisivos inferiores bovinos com 15 mm de comprimento e diâmetro do canal máximo de 2 mm, as quais foram divididas em 8 grupos experimentais (n = 10). Os grupos experimentais são descritos a seguir: G1 - cimento resinoso experimental, sem adição do sal DFI, contendo 2 mol % de EDAB; G2 - cimento resinoso experimental, com adição de 0,5 mol % do sal DFI, contendo 2 mol % de EDAB; G3 - cimento resinoso experimental, com adição de 1 mol % do sal DPI, contendo 2 mol % de EDAB; G4 - cimento resinoso experimental, sem adição do sal DFI, contendo 2 mol % de DMAEMA; G5 - cimento resinoso experimental, com adição de 0,5 mol % de DFI, contendo 2 mol % de DMAEMA; G6 - cimento resinoso experimental, com adição de 1 mol % de DFI, contendo 2 mol % de DMAEMA; G7 - cimento resinoso comercial Variolink II, versão foto-ativável, utilizando apensas a pasta base; G8 - cimento resinoso comercial Variolink II (Ivoclar-Vivadent), versão dualmente ativável, utilizando as pastas base e catalisadora. Para todos os grupos, o protocolo adesivo utilizado foi condicionamento ácido, seguido pela aplicação do primer e bond Scotchbond Multipurpose (3M ESPE). Após a cimentação, o teste de resistência de união push-out foi realizado a uma velocidade de 1 mm/min, utilizando uma célula de carga de 200 N e os valores expressos em MPa. A análise do padrão de fratura foi realizada em lupa estereoscópica (LEICA MZ75 50X). Os dados coletados foram submetidos à Análise de Variância a um critério com parcelas subdivididas e teste de Tukey (?=0.05). Os resultados obtidos demonstraram que não houve diferença estatística entre o comportamento dos cimentos devido à influência das diferentes aminas; os cimentos experimentais resinosos que continham o sal DFI (grupos 2,3,5 e 6) apresentaram os maiores valores de resistência de união para todos os terços estudados (cervical, médio e apical), sendo estes estatisticamente semelhantes ao cimento resinoso comercial Variolink II dual (grupo 8). Os menores valores apresentados foram para os cimentos que não continham o sal DFI (grupos 1 e 4) e para o cimento resinoso comercial Variolink II foto-ativável (grupo 7), sendo estes estatisticamente semelhantes no terço apical. O cimento resinoso experimental foto-ativável contendo sal de DFI se mostrou capaz para a cimentação de pinos de fibra de vidro, sendo estatisticamente semelhantes ao cimento resinoso comercial Variolink II Dual, e superiores ao mesmo cimento em sua versão fotoativável. A região apical demonstrou para todos os grupos os menores valores de resistência de união. O tipo de amina terciária e a concentração do sal de DFI (0,5 e 1 mol %) não influenciaram a resistência de união de pinos de fibra de vidro à dentina radicular / Abstract: The aim of this study was to evaluate, in vitro, the bond strength (push-out) of fiber posts fixed with experimental photo-activated resin cements with the addition of different concentrations of hexafluorophosphate dipheniliodonium salt (DFI), also varies between tertiary amines EDAB and DMAEMA in cementation of fiber posts, and compare them to a resin cement available in the market in its dual and photo-activatable version. A total of 80 bovine incisors roots of similar dimensions were used, which were divided into eight experimental groups (n = 10). Experimental groups are described below: G1 - experimental resin cement without addition of DFI salt, containing 2 mol% EDAB; G2 - experimental resin cement, with addition of 0.5 mol% of DFI salt containing 2 mol % of EDAB; G3 - experimental resin cement with addition of 1 mol% of DFI salt, containing 2 mol% EDAB; G4 - experimental resin cement without addition of DFI salt, containing 2 mol% DMAEMA; G5 - experimental resin cement, with addition of 0.5 mol% DFI salt, containing 2 mol% DMAEMA; G6 - experimental resin cement with the addition of 1 mol% DFI salt, containing 2 mol% DMAEMA; G7 - commercial resin cement Variolink II, photo-activatable version, using the base paste; G8 - commercial resin cement Variolink II, version dually activatable, using the base and catalyst pastes. For all groups, the adhesive protocol used was, etching, followed by application of primer and bond Scotchbond Multipurpose. After cementation, the bond strength test push-out was conducted at a speed of 1 mm / min, using a load cell of 200 N and the values expressed in MPa. The pattern of fractures was performed by stereoscopy magnifier (LEICA MZ75 50X). The collected data were subjected to ANOVA for a split-plot criterion and the Tukey test (? = 0.05). The results showed that there was no statistical difference in the behavior of cements due to influences of the different amines; experimental resin cements containing salt DFI (groups 2,3,5 and 6) showed the highest bond strength for all the studied thirds (cervical, middle and apical), which are statistically similar to the commercial resin cement Variolink II Dual (group 8). The lowest values were submitted to the cements containing no DFI salt (groups 1 and 4) and the commercial resin cement Variolink II photo-activable (group 7), which were statistically similar in the apical third. The experimental resin cements containing DFI salt are capable for fiber glass posts cementation, being statistically similar to the commercial resin cement Variolink II Dual, and even above the cement in the version photo-activable. The variation of tertiary amines did not influence the results of bond strength and there was no statistically difference between the concentrations 0.5 mol% and 1 mol% of DFI salt / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
32

Influência do modo de aplicação e viscosidade do ácido fosfórico 37% na adesão de pinos de fibra de vidro em condutos radiculares

Scholz, Maria Fernanda Costa 23 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-31T17:05:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) / Made available in DSpace on 2018-07-31T17:05:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) Previous issue date: 2018-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar a influência da viscosidade do ácido fosfórico e do modo de aplicação nos valores de resistência de união de pino de fibra de vidro cimentados na dentina radicular através do teste de pushout. Raízes de 32 pré-molares foram preparadas endodonticamente e divididas em 4 grupos (n = 8) de acordo com a combinação dos seguintes fatores: viscosidade do ácido e forma de aplicação. Após aplicação do adesivo Universal no interior dos condutos, foram realizadas as cimentações dos pinos com o cimento resinoso RelyX ARC. Em seguida, as raízes foram seccionadas transversalmente em 6 fatias de aproximadamente 1 mm e o teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os resultados de resistência de união foram submetidos a uma análise de variância de três fatores de medidas repetidas e teste de Tukey (alpha = 0.05). A interação dupla modo de aplicação vs. viscosidade do ácido (p = 0,0002) e o terço radicular (p < 0,0001) foram estatisticamente significantes. O maior valor de resistência de união foi observado no grupo condicionado com ácido fosfórico líquido sob o modo de aplicação sônica (p < 0,05) sendo todos os outros grupos semelhantes entre si. Quanto ao terço radicular, observou-se maior valor de resistência de união no terço cervical, seguido do terço médio e do terço apical terço apical (p < 0,05). Pelos resultados pode-se concluir que uma melhor adesão de pinos de fibra de vidro ao conduto radicular pode ser obtida através do condicionamento com ácido fosfórico líquido com aplicação sônica. / The aim of the present study was to evaluate the influence of the etchant viscosity (liquid or gel) and the application mode (passive or sonic) on the pushout bond strength values of fiberglass post to root dentin and the conditioning pattern on the smear-layer covered root dentin before cementation. The roots of premolars were prepared endodontically and divided into 4 groups (n = 8) according to the combination of the main factors: phosphoric acid viscosity (liquid gel) and application mode (passive or sonic). After the application of the universal adhesive into the root canals, the fiberglass posts were cemented with cementation system RelyX ARC. Then, the roots were sectioned transversely 6 slices of approximately 1 mm and the push-out test performed at a speed 0.5 mm/min. The results were submitted to a repeated measures three-way ANOVA and Tukey’s test (alpha = 0.05). The cross-product interaction mode of application vs. etchant viscosity (p = 0.0002) and the main factor root third (p < 0.0001) were statistically significant. The highest bond strength value was observed when the conditioning of the root canal was performed with a liquid phosphoric acid under sonic application mode (p < 0.05), being all other groups similar one another (p < 0.05). Regarding the root third, the highest push-out bond strength value was observed in the cervical third, followed by the medium third and the apical thirds (p < 0,05). The most common fracture pattern was the mixed failure. By the partial results one may conclude that a better bonding of fiberglass posts to root canals can be achieved when the conduits are conditioned with a
33

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
34

Efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina

Soares, Luiz Felipe Valandro [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 soares_lfv_dr_sjc.pdf: 2172167 bytes, checksum: afe324626620aad27736c29fa48ab77b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina. As hipóteses desse trabalho são que a resistência adesiva não varia após o teste de fadiga e também não varia em função do tipo de pino de fibra. A parte coronária de 60 dentes humanos unirradiculares foi seccionada, obtendo-se espécimes (sp) de 16mm, que foram submetidos à instrumentação endodôntica e então 30 sp foram preparados (12mm) para receber um pino de fibra de quartzo (D.T. Light-Post) [DT] e 30 foram preparados para um pino de fibra de vidro (FRC Postec Plus) [FRC]. Os pinos foram cimentados (All-Bond + cimento resinoso Duolink) e a parte radicular dos sp foi embutida em resina epóxica até 3mm da porção cervical. Foram constituídos 6 grupos (n=10), considerando o tipo de pino de fibra e o regime de ciclagem mecânica (carga: 50 N; 45° em relação ao longo eixo do sp; freqüência: 8Hz): G1- DT + sem ciclagem; G2- DT + 20.000 ciclos; G3- DT + 2.000.000 ciclos; G4- FRC + sem ciclagem; G5- FRC + 20.000 ciclos; G6- FRC + 2.000.000 ciclos. Os sp foram então seccionados perpendicularmente ao longo eixo do sp,obtendo-se fatias de aproximadamente 2mm (4 secções / sp) que foram submetidas ao ensaio de push-out em máquina de ensaio universal (1mm.min-1). A média de resistência adesiva das repetições de cada espécime foi obtida e os dados (n=10) foram submetidos à análise estatística (a=0,05). A ANOVA mostrou que: (a) as resistências adesivas do pino DT (7,12 l 2,20 MPa) e do pino FRC (6,87 l 2,12 MPa) foram estatisticamente semelhantes entre si (P=0,665); (b) os valores obtidos para a condição sem ciclagem (6,96 l 2,44 MPa), 20.000 (6,99 l 2,08 MPa) e 2.000.000 (7,02 l 2,00 MPa) foram similares estatisticamente (P=0,996); (c) os 6 grupos foram estatisticamente semelhantes entre si (P=1,000)... / This study evaluated the effect of the mechanical cycling on the bond strength of fiber posts resin bonded to root dentin. The tooth crown of the 60 single-rooted human teeth was cut, leaving a 16-mm long root specimens (sp) that were endondontically treated and the space prepared in 12mm. Thirty sp received a quartz fiber post (D.T. Light-Post) and 30 sp received a glass fiber post (FRC Postec Plus). The posts were resin luted in the post space and each sp was embedded with epoxy resin (resin 285, Schaller, Florence, Italy) in a PVC cylinder (height: 25 mm, diameter: 10 mm). Sp were divided into 6 groups, considering the fiber post type and number of the mechanical cycles (load: 50 N; angle of 45°; frequency: 8Hz): G1- DT + without cycling; G2- DT + 20,000 cycles; G3- DT + 2,000,000 cycles; G4- FRC + without cycling; G5- FRC + 20,000 cycles; G6- FRC + 2,000,000 cycles. The sp were cut perpendicular to their long axis, to form 2-mm-thick disk-samples (4 sections / sp), which were submitted to the push-out test (1mm.min-1). The mean bond strength values were calculated for each tooth (n=10) and data were statistical analyzed (a=.05). ANOVA revealed that: (a) the bond strengths of DT (7,12 l 2,20 MPa) and of FRC (6,87 l 2,12 MPa) were statistically similar (P=0,665); (b) the mean values for the without cycling groups (6,96 l 2,44 MPa), 20,000 cycles groups (6,99 l 2,08 MPa) and 2,000,000 cycles groups (7,02 l 2,00 MPa) were not statistically different (P=0,996); (c) the 6 groups were not statistically different (P=1,000). It was concluded that the mechanical cycling did not affect the bond strength of two fiber posts resin bonded to dentin.
35

RESISTÊNCIA À FRATURA DE DENTES COM RAÍZES FRAGILIZADAS RESTAURADOS COM DIFERENTES RETENTORES INTRARRADICULARES / FRACTURE RESISTANCE OF WEAKENED ROOTS RESTORED BY DIFFERENT POST SYSTEMS

Broch, Juliana 02 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Taking into account the importance of developing techniques to restore teeth with excessively flared root canals, this study aimed to evaluate the effect of mechanical cycling on the fracture resistance of teeth with weakened roots, restored with different techniques, as well as to analyze the failure modes after fracture testing. Eighty (N=80) bovine lower incisors were selected and the coronal and cervical portions were sectioned to standardize the specimens length at 15 mm. The roots were endodontically treated and prepared to 10 mm in intracanal length. The cervical portion of the root inner surface (5 mm) was enlarged (removing the intracanal dentin) using a diamond drill (KG Sorensen #4138) to produce a radicular wall with 1 mm in thickness. The specimens were embedded with acrylic resin and the periodontal ligament was simulated with a polyether material. Afterwards, the specimens were randomly allocated in 4 intracanal restoring strategies: cast post and core; double-tapered glass fiber post with cervical emerging diameter of 1.8 mm; double-tapered glass fiber post with cervical emerging diameter of 2.2 mm; anatomic posts (fiber posts relined with composite resin). Each restoring method was assessed without or with mechanical cycling, applying the protocol as followed: angle of 45º, 37ºC temperature, load of 88N, frequency of 2.2 Hz, 1.000.000 load-pulses. All of the restored teeth received metal full crown (Ni-Cr). All the specimens were submitted to fracture resistance at 45º and at a cross-head speed of 0.5 mm/min. Two-way ANOVA and Tukey showed that the root post system (p < 0.0004), the mechanical cycling (p < 0.003) and the interaction between the factors (p < 0.02) were statistically significant. The restoring methods with fiber posts did not change after mechanical cycling. Its fracture strength values were similar to that from cast post and core. The anatomic post suffered degradation with the mechanical cycling (the values reduced after aging). Concerning the mode of failure, the most failure from groups restored with cast post and core were catastrophic while the others groups showed a predominance of repairable failures. / Diante da necessidade do desenvolvimento de técnicas capazes de restaurar adequadamente raízes com condutos alargados, este trabalho visou avaliar o efeito da ciclagem mecânica sobre a resistência à fratura de dentes com raízes fragilizadas e restaurados com diferentes retentores intrarradiculares, bem como analisar o padrão de falha destes dentes quando submetidos à carga compressiva. Foram utilizados para este estudo 80 incisivos inferiores bovinos, cujas raízes foram seccionadas em 15 mm de comprimento, tratadas endodonticamente e preparadas até 10 mm de profundidade. Os 5 mm cervicais dos canais radiculares destas raízes foram fragilizados com uma ponta diamantada (4138), de modo a gerar uma espessura de parede radicular de 1 mm. As raízes foram incluídas em resina acrílica autopolimerizável e o ligamento periodontal foi simulado com material elastomérico (poliéter). Após, as raízes foram distribuídas aleatoriamente em quatro sistemas de retentores intrarradiculares: núcleo metálico fundido, pino de fibra de vidro (pinos de dupla conicidade, 1,8 mm de diâmetro cervical), pino de fibra de vidro especial (pinos de dupla conicidade, 2,2 mm de diâmetro cervical) e pino anatômico. Cada um desses sistemas de retentores foi avaliado com e sem ciclagem mecânica, sendo o protocolo de ciclagem o seguinte: angulação de 45°, temperatura de 37°C, força de 88N, freqüência de 2,2 Hz, totalizando 1 milhão de ciclos; durante a mesma os espécimes dos grupos sem ciclagem mecânica ficaram armazenados em água destilada. Em todos os grupos, foram cimentadas coroas totais metálicas de Níquel-Cromo sobre o núcleo. Os corpos de prova de todos os grupos foram submetidos ao teste de resistência à compressão em uma inclinação de 45° e à velocidade de 0,5 mm/mim até ocorrer a falha. A análise de Variância seguida de Tukey mostrou que o tipo de retentor intrarradicular (p < 0,0004), a ciclagem mecânica (p < 0,003) e a interação entre ambos (p < 0,02), foram estatisticamente significantes. Os pinos de fibra de vidro mantiveram-se estáveis após a ciclagem mecânica, com valores de resistência à fratura similares aos núcleos metálicos fundidos. Somente pinos anatômicos sofreram degradação com a ciclagem, reduzindo significativamente os valores de resistência à fratura. Em relação ao padrão de falha, foram fraturas predominantemente irreversíveis nos grupos reconstruídos com núcleo metálico fundido, e nos demais, reversíveis.
36

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
37

Biodinamica restauradora de dentes tratados endodonticamente : analise por elementos finitos / Restorative biomechanical of endodontic treated teeth : finite element analysis

Santos Filho, Paulo Cesar de Freitas 04 June 2009 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T11:40:25Z (GMT). No. of bitstreams: 1 SantosFilho_PauloCesardeFreitas_D.pdf: 10660151 bytes, checksum: bd3f67697b369623400074dcf22ec01c (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi desenvolver protocolo de modelagem tridimensional para incisivo central superior com aplicabilidade ao método de elementos finitos e avaliar o comportamento biomecânico de incisivo superior tratado endodonticamente e restaurado com retentores e coroa cerâmica por meio de análise por elementos finitos comparado ao dente hígido. Para geração do modelo 3D foi selecionado incisivo central superior hígido. Esmalte e dentina foram degradados em diferentes fases com ácido clorídrico-10%, e mapeados com scanner de contato 3D (Modela, Roland). Para o mapeamento do volume pulpar, a dentina foi seccionada longitudinalmente no sentido mesio-distal e realizado o escaneamento do espaço negativo referente à polpa. Os arquivos *.STL foram exportados para programa Bio-CAD (Rhinoceros-3D). Volumes de cada estrutura dental e técnicas restauradoras foram gerados por meio da associação de superfícies NURBS. Os modelos foram exportados para o programa de elementos finitos (FEMAP-NeiNastran), onde foi realizado o processo de malhagem, inserção das propriedades mecânicas e condições de contorno. Foram gerados 17 modelos, sendo um do dente hígido e 16 modelos de acordo com os 4 fatores em estudo: tipo de retentor em dois níveis: pino de fibra de vidro (PFV) e núcleo moldado fundido (NMF), extensão do retentor em dois níveis: 7,0mm (7,0) e 12,0mm (12,0), remanescente coronário em dois níveis: remanescente de 2,0mm (RE) e ausência de remanescente (ARE), enfraquecimento do canal radicular em dois níveis: ausência de enfraquecimento (AENF) e presença de enfraquecimento (ENF). Foi simulada aplicação de pressão constante no valor de 100N perpendicularmente à superfície palatina do incisivo. Os resultados foram analisados pelo critério de von Mises e tensão máxima principal. Os resultados obtidos mostraram que o modelo geométrico 3D desenvolvido é adequado para a análise por elementos finitos. Concluiu-se que o PFV apresenta distribuição homogênea das tensões mais semelhante ao dente hígido, enquanto o NMF apresentou grande concentração de tensão no interior do canal radicular. O fator extensão do retentor intra-radicular influenciou isoladamente apenas a distribuição de tensões do NMF. A presença de remanescente coronário sempre melhorou a distribuição de tensões. O enfraquecimento do canal radicular teve maior impacto na distribuição de tensões. / Abstract: The aim of this study was develop 3D model generation protocol for upper anterior teeth for finite element analysis and evaluate biomechanical behavior of endodontically treated incisor with finite element analysis compared to sound teeth. It was selected intact upper central incisor. Enamel and dentin were treated in different steps with cloridric acid 2% and scanned with 3D-contact scanner. The stereolithographics archives were exported to Bio CAD program. The volums of each dental structure and restorative techniques were generated by association of NURBS surfaces. The models were exported for finite element software, where were realized the meshed process, mechanical properties insertion and bondary conditions. It were generated 17 models, one was a sound incisor model and 16 models according to 4 studied factors: post type: glass fiber post (GFP) and cast post and core (CPC), post length: 7,0mm (7,0) e 12,0mm (12,0), ferrule: 2,0mm ferrule (FE) and absence of ferrule (AFE), weakness of root canal: absence of weakness (AWR) and weakened root (WR). It was simulated 100N loading application on the palatal surface with 135° angulation. The results were analised by Von Mises criteria and principal maximum tension. Obtained results showed that geometric model developed is appropriated for finite element analysis. It can be concluded that GFP showed homogeneous stress distribution like the sound incisor, while CPC showed stress concentration into root canal. The post length influenced only the CPC stress distribution. The ferrule always showed better stress distribution. The weakness of root showed the highest impact in stress distribution. / Doutorado / Dentística / Doutor em Clínica Odontológica
38

Efeito do tipo de pino, altura do remanescente coronário e carregamento na distribuição de tensões em prótese fixa de três elementos / Effect of post, ferule presence and loading on stress distribution in 3-unit fixed parcial denture

Silva, Gisele Rodrigues da, 1982- 12 July 2012 (has links)
Orientador: Luís Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T16:51:03Z (GMT). No. of bitstreams: 1 Silva_GiseleRodriguesda_D.pdf: 2969310 bytes, checksum: 065fbdffc0e741bd55d3cb562acde2e8 (MD5) Previous issue date: 2012 / Resumo: O objetivo deste estudo foi investigar a influência do retentor intrarradicular, altura do remanescente coronário e tipo de carregamento virtualmente simulado, no comportamento biomecânico de prótese fixa anterior de 3 elementos. Quatro modelos tridimensionais de elementos finitos foram criados comparando-se o tipo de retentor nos dentes pilares (fibra de vidro ou núcleo metálico fundido) e a altura do remanescente coronário (0 e 2 mm). Para simular o tipo de carregamento foram considerados dois níveis de aplicação da força: 1- simulação de contato protrusivo (PRT): 200 N distribuídos nas cristas marginais palatinas dos incisivos superiores, sendo 50 N em cada crista marginal, a 45o do longo eixo do dente e 2- simulação de contato em lateralidade canina (LAT): 200 N aplicados na palatina do canino a 15º. Todos os materiais foram considerados homogêneos, lineares, elásticos e isotrópicos com exceção do pino de fibra de vidro, que foi considerado transversalmente isotrópico. O problema estrutural foi solucionado computacionalmente pelo Método de Elementos Finitos (MEF), em análise estrutural estática. A coerência da simulação foi observada pela análise do deslocamento e pelas tensões de von Mises. O deslocamento foi analisado de forma qualitativa e quantitativa comparando-se a região de deslocamento máximo sofrido pela prótese. Em seguida, foram comparadas as tensões máximas principais ocorridas na região de conexão entre pôntico e dentes pilares, na raiz do incisivo central, do canino e nas interfaces pino-dentina radicular e núcleo de preenchimento-dentina. Concluiu-se que as tensões de tração são concentradas entre pôntico/ pilar e na palatina dos dentes pilares da prótese fixa anterior. Sendo que a protrusão gera maior concentração de tensão máxima principal de tração nos dentes pilares e gera deslocamento duas vezes maior do que a lateralidade. Ademais, a presença de remanescente coronário melhora a distribuição das tensões e o pino de fibra de vidro mostrou-se adequado em prótese fixa anterior de 3 elementos / Abstract: The aim of this study was to investigate the influence of post, load condition and ferule presence in abutment teeth on the stress distribution in the anterior three-unit fixed dental prosthesis (FDP) made of lithium dissilicate. Four three-dimensional finite element (FE) models were created comparing the type of post using on the abutment teeth in two levels (fiberglass post and cast post-and-core) and the coronal remaining in two levels (with or without ferule presence). Two load conditions were applied: 1- 200 N was distributed on palatine marginal ridge of incisive, with 50 N in each ridge, under a 45o angle with the long axis of the tooth, simulating the protrusive contact or 2- 200N was applied on palatine of canine at 15o. All materials were considered homogeneous, linear elastic, and isotropic, with the exception of the glass fiber post, which was considered transversally isotropic. Analysis by Finite Elements Method (FEM), was performed structural analysis. The displacement and Von Mises stress was applied to analyze the coherence o simulation. The displacement was analyzed by quality and quantity resuts in region of maximum prostheses displacement. Maximum principal stress was used as a criterion to compare the study factors. The stress distribution was compared in a descriptive way in the area of the connector, along the interface post/dentin and core/dentin and on abutment dentin teeth. In conclusion, the highest tensile stress was observed in the connector areas and on palatine abutments roots surfaces. The protrusion causes higher stress and displacement than canine guide. The ferrule presence in the abutment teeth reduced the maximum principal tensile stresses on tooth-restoration complex and the fiberglass post seems to improve the stress distribution on anterior 3-unit fixed-dental prostheses / Doutorado / Dentística / Doutora em Clínica Odontológica
39

Influencia do reembasamento com resina composta na resistencia a extrusão de retentores intra-radiculares de fibra de vidro / Influence of resin composite relining on the extrusion strengh of intraradicular fiber glass posts

Pedrosa Filho, Celso de Freitas 24 November 2006 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T21:42:27Z (GMT). No. of bitstreams: 1 PedrosaFilho_CelsodeFreitas_D.pdf: 1514708 bytes, checksum: 68479f75bac6f0d3bdbb5ec943719f31 (MD5) Previous issue date: 2006 / Resumo: Neste estudo avaliou-se a resistência ao cisalhamento por extrusão de pinos de fibra de vidro, reembasados ou não com compósito, cimentados com cimento resinoso em dentina intra-radicular, avaliando os segmentos cervical, médio e apical. Selecionaram-se 20 incisivos bovinos com dimensões semelhantes, removendo a porção coronária, padronizando o comprimento das raízes em 16 mm. Após, incluiu-se as raízes em resina acrílica, realizando tratamento endodôntico e, então o preparo dos espaços para os pinos, dividindoas, em seguida, aleatoriamente em dois grupos com dez amostras cada. Os elementos do grupo 1 receberam pinos de fibra de vidro somente cimentados, e do grupo 2 pinos de fibra de vidro reembasados com compósito e posteriormente cimentados. Ao término dos procedimentos de cimentação, realizou-se a secção dos segmentos radiculares, submetendo, então, os corpos-de-prova ao teste push-out em máquina de ensaios universal, através de ponta ativa cilíndrica com 1 mm de diâmetro, à velocidade de 0,5 mm/min, até extrusão do retentor. Obteve-se os seguintes valores médios de resistência de união, em MPa: grupo 1, terços cervical = 6,24 ± 2,68(b), médio = 4,27 ± 2,00(b) e apical = 4,46 ± 2,82(b); grupo 2, terços cervical = 11,83 ± 1,69(a), médio = 11,81 ± 3,86(a) e apical = 10,39 ± 2,44(a). Submeteram-se os valores à análise de variância e ao teste de Tukey com nível de significância de 5%, indicadas acima através de letras diferentes. Os pinos de fibra de vidro reembasados com compósito apresentaram valores estatisticamente superiores de união em todos os segmentos radiculares quando comparados com pinos somente cimentados. Observou-se também a ausência de diferença significativa entre os terços radiculares avaliados para cada grupo distintamente. Os resultados demonstraram que a técnica de reembasamento mostrou-se efetiva em melhorar a retenção do pino de fibra de vidro estudado / Abstract: This study evaluated the bond strength of fiber posts, relined or not with composite resin, luted with resinous cement to radicular dentin, evaluating cervical, median and apical root segments. Twenty bovine incisors, with similar dimensions, were selected and cut 16 mm from the apical limit. The roots were embedded in acrylic resin and the radicular canals were root treated and post space prepared with a depth of 9 mm. Samples were randomly assigned to two groups of ten roots each. Group 1 received glass fiber posts (Fibrekor) luted with dual-cure resin cement (RelyX ARC) in association with a bonding system (Adper Single Bond). In Group 2 the same type of posts were relined with composite (P-60) for further cementation with the same materials used in Group 1. After cementation procedures roots were sectioned transversally and three sections, from cervical, medium and apical thirds were obtained. Push-out test was performed in a universal testing machine with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion. Collected data was statistically analyzed by twoway ANOVA and Tukey HSD test (p<0,05). The measured retention strengths for cervical, medium and apical thirds were: Group 1, 6.24 ± 2.68(b), 4.27 ± 2.00(b) and 4.46 ± 2.82(b) ; Group 2, 11.83 ± 1.69(a), 11.81 ± 3.86(a) and 10.39 ± 2.44(a). Glass fiber composite relined posts presented statistically higher retention values in cervical, medium and apical thirds when compared to non-relined posts. Within each group, no differences were found among radicular thirds. The results indicate that the tested technique showed effective improvement of glass fiber post retention strength / Doutorado / Dentística / Doutor em Clínica Odontológica

Page generated in 0.1144 seconds