• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 64
  • 33
  • 13
  • 12
  • 9
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Diferentes horários de arraçoamento sobre o desempenho e qualidade de ovos matrizes de frangos de corte / Different feeding schedules on the parameters and egg quality in broilers breeders

Londero, Angélica 24 February 2015 (has links)
A study was carried out at Poultry Science Laboratory LAVIC at the Federal University of Santa Maria UFSM. The aim was avaluated the effect of different feeding schedules on the performance and eggs quality of broilers breeders Cobb 500. The experimental period was separated into two phases, the first from 28th to 40th week (Phase I) and the second from 40th to 60th week (Phase II) of hen s age. The feeding schedules evaluated were: a single feeding at 08:00 am; twice daily feeding (50% at 08:00 am and 50% at 3:00 pm) and a single feeding at 3:00 pm. At the Phase I, was used 546 females and 63 males allocated in a completely randomized design (CRD) with 7 pens with 26 females and 3 males per repetition and, to the Phase II was used 330 females and 45 males assigned in a CRD with 5 pens with 22 females and 3 males by repetition. The diets were based on corn and soybean meal. At the Phase I, the egg production of hens fed at 3 pm was reduced (P=0.0002). These hens had higher egg and yolk weight than hens fed at 8 am. Hens fed at 3 pm showed better shell quality (egg specific gravity, weight and thickness). The bacterial contamination of the shell was not affected by the diffirent feeding schedules, as well as hatchability, fertility, contaminated and pipped eggs. Embryonic mortality was the lowest in eggs came from hens fed at 8 am. The hatchability of fertile shown to be higher in hens fed once daily in the morning than broiler breeders fed twice daily. At the Phase II, the egg production was not affected by feeding schedules. The hens fed in the afternoon had higher egg and shell weight tham others. The hens fed at 3 pm had higher egg specific gravity and eggshell thickness than eggs come from hens fed at 8 am. Calcium (Ca) and phosphorus (P) plasma levels (21 hours after laying) were higher in hens fed at 3 pm than hens fed at 8 am. The tibia weight was higher in hens fed 8 am than hens fed twice daily feeding. A single feeding at 3:00 pm showed lowest egg production of the 28th to 40th weeks of age. Broiler breeders fed in the afternoon had better egg quality and bacteriological differences were not found in the eggs of hens fed at different schedules. / Um estudo foi conduzido no Laboratório de Avicultura LAVIC da Universidade Federal de Santa Maria (UFSM) com o objetivo de avaliar o efeito de diferentes horários de arraçoamento sobre o desempenho e qualidade de ovos de matrizes de frangos de corte da linhagem Cobb 500. O período experimental foi dividido em duas fases, a primeira da 28ª a 40ª semanas (Fase I) e a segunda da 40ª a 60ª semanas (Fase II) de idade das aves. Avaliaram-se três horários de arraçoamento: único - 8hs; duas vezes ao dia (50% às 8hs e 50% às 15hs) e único - 15hs. Na Fase I foram utilizadas 546 fêmeas e 63 machos distribuídos em um deliamento inteiramente casualizado (DIC) composto por 7 repetições de 26 fêmeas e 3 machos. Na Fase II utilizou-se 330 fêmeas e 45 machos distribuídos em um DIC composto por 5 repetições de 22 fêmeas e 3 machos. As dietas foram à base de milho e farelo de soja. Na Fase I, a taxa de postura de aves alimentadas às 15hs foi reduzida (P=0.0002). Estas aves apresentaram maior peso de ovo e gema em comparação às aves alimentadas às 8hs e, aves alimentadas às 15hs apresentaram melhor qualidade de casca (gravidade específica, peso e espessura) em relação às demais. A contaminação bacteriológica da casca não foi afetada pelos diferentes horários de arraçoamento, bem como eclodibilidade, fertilidade, ovos contaminados e bicados. A mortalidade embrionária foi menor em ovos resultantes de matrizes arraçoadas às 8hs. Estas aves produziram ovos que apresentaram maior taxa de eclodibilidade de ovos férteis em relação às aves alimentadas duas vezes ao dia. Na Fase II, a taxa de postura não foi afetada pelos horários de arraçoamento. Matrizes alimentadas à tarde apresentaram maior peso de ovo e casca em relação às demais. Estas aves apresentaram maior gravidade específica e espessura de casca em relação às aves alimentadas às 8hs. Cálcio (Ca) e fósforo (P) plasmáticos (21 horas após a postura) foram maiores em matrizes arraçoadas às 15hs em relação às aves alimentadas apenas às 8hs. Matrizes alimentadas às 8hs apresentaram maior peso de tíbia do que aquelas alimentadas duas vezes ao dia. O arraçoamento único às 15hs demonstrou menor produção de ovos da 28ª a 40ª semanas de idade. Matrizes alimentadas a tarde apresentam melhor qualidade de ovos, sendo que não foram encontradas diferenças bacteriológicas nos ovos das aves alimentadas em diferentes horários.
52

Fixador esquelético externo circular para o tratamento de fraturas rádio e tíbia em cães

Gonzalez, Paula Cristina Sieczkowski January 2013 (has links)
O fixador esquelético externo circular foi desenvolvido durante a guerra fria na Rússia, pelo Professor Gavril Abramovich Ilizarov. Esse tipo de fixação ganhou espaço como alternativa à fixação interna, devido a sua versatilidade e às suas características biomecânicas que otimizam a formação do calo ósseo. O objetivo desse estudo foi avaliar o fixador esquelético externo circular como método de fixação para fraturas metafisárias de rádio e tíbia de cães atendidos no Hospital de Clínicas Veterinárias da UFRGS. Os resultados a respeito do tipo e frequência de complicações associados a essa técnica foram documentados. No total 16 animais cumpriram os critérios para entrar no estudo sendo sete fêmeas e nove machos. A idade média dos animais foi de 50,87 ± 57,01 meses com peso médio dos animais foi de 8,6 ± 6,95kg. Três (18%) animais apresentaram fratura de tíbia e fíbula e treze (82%) fraturas de rádio e ulna. O aparelho de fixação esquelética utilizado consistiu de um aro proximal 5/8 e dois aros distais inteiros, com dois fios em cada anel. Os fios foram colocados de maneira divergente o mais próximo possível de 90°. O aparelho pesou em média 128 ± 49g, representando em média 4,09 ± 3,22% do peso do animal. O tempo médio de cirurgia foi de 115 ± 32 minutos. O tempo médio de permanência com o aparelho de fixação esquelética externa circular foi de 81,69 ± 23,14 dias. Entre as complicações encontradas estão: tratos de drenagem ao redor dos fios (37,5%), miíase (6,25%), encurtamento dos músculos flexores do antebraço (6,25%), hemorragia associada ao local de passagens dos pinos (6,25%) e quebra do fio com deslocamento do fixador levando a necessidade de sua remoção (6,25%). Não houve diferença estatística entre os tempos cirúrgicos necessários para a osteossíntese de rádio e tíbia. Não houve correlação entre as variáveis: tempo decorrido do trauma até a cirurgia e tempo de duração da cirurgia; tempo decorrido do trauma até a cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular; peso do animal e duração da cirurgia; proporção do peso do circular em relação ao peso do animal e o tempo de permanecia com o circular. Houve correlação positiva estatisticamente significativa entre as variáveis: duração da cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular. Essa modalidade de tratamento representa uma opção cirúrgica atrativa para a correção de fraturas de rádio e tíbia em cães, entretanto, devido à possibilidade complicações e necessidade de cuidados pós-operatórios intensivos uma seleção acurada dos pacientes e proprietários deve ser realizada previamente à cirurgia. / The circular external skeletal fixator was developed during the Cold War in Russia, by Professor Gavril Abramovich Ilizarov. This kind of fixation took place as an alternative to internal fixation, due to its versatility and its biomechanical characteristics that improves the formation of callus. The aim of this study was to evaluate the circular external skeletal fixator as a method of fixation for fractures of the radius and tibia of dogs treated at the Veterinary Teaching Hospital of UFRGS, corroborating the results, the type and frequency of complications associated with this technique. Sixteen animals met the criteria to participate on the study, seven females and nine males. The average age of the animals was 50.87 ± 57.01 months. The average weight of the animals was 8.6 ± 6.95 kg. Three (18%) animals showed fracture of tibia and fibula and thirteen (82%) fractures of the radius and ulna. The circular external skeletal fixation frame used consisted of a proximal ring ⅝ and two full distal rings, with two wires in each ring. The wires were placed divergently as close as possible to 90 °. The frame weighed on average 128 ± 49g, representing average 4.09 ± 3.22% of the weight of the animal. The mean time of the surgery was 115 ± 32 minutes. The average time spent with the circular was 81.69 ± 23.14 days. Among the complications found are drainage tracts around the pins (37.5%), myiasis (6.25%), shortening of the forearm flexors (6.25%), hemorrhage associated with the location of pins passages (6, 25%) and breakage of the device wire with displacement of the frame leading to its removal (6.25%). There was no statistical difference between the times required for the surgical fixation of the radius and tibia. There was no correlation between the variables: time elapsed from trauma to surgery and duration of surgery, time elapsed from trauma to surgery and time spent with the circular external skeletal fixation; animal weight and duration of surgery; the proportion of the circular weight in relation to the weight of the animal and the time remained with the circular. There was statistically significant positive correlation between the variables: duration of the surgery and the permanency with the circular external skeletal fixation. This treatment modality represents an attractive surgical option for fractures correction of the radius and tibia in dogs, however, due to possible complications and need for intensive post operative care accurate selection of patients and owners should be performed prior to surgery.
53

Células tronco mononucleares autólogas na cicatrização de defeitos tibiais agudos experimentais de cão / Autologous mononuclear stem cells in dogs: experimental acute tibial defect healing

Oliveira, Graziela Kopinits de 07 May 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This research was aimed at evaluating the mononuclear stem cells (MSC) use in experimental bone defect healing, as an alternative to the conventional methods, analyzing the healing speed, and the presence of these cells in the new-born tissue. The bone marrow (BM) was collected from 18 dogs, counted and morphometrically analyzed, through manual count and myelogram. The dogs were separated in three groups (G1, G2, G3) of six animals. A surgical tibial bone defect was made then, in each dog and the wound was treated with gelatin sponge and physiologic solution (G1), gelatin sponge and processed bone marrow (G2) and gelatin sponge, processed BM and morphogenetic bone protein (G3). The healing was then evaluated through radiographic study and the presence of MSC was identified through Qtracker nanocrystal labeler and fluorescent light microscopy one week after the surgery. Cells from the bone lineage were found among the labeled cells. The radiographic evaluations demonstrate speeding in bone growth in the groups G2 and G3, and were significant statistically differences between the G1 and G3 in all studied periods and between G1 and G2 at the 30 and 45 days period. The supplemented or not-supplemented with rhBMP-2 adult mononuclear stem cells use are favorable alternatives to the speed the healing process of acute dog tibial experimental defects. / Nesta pesquisa foi abordada a utilização de células-tronco mononucleares (CTM) na cicatrização de defeito ósseo experimental, como alternativa aos métodos convencionais, analisando-se a velocidade da cicatrização, além da presença dessas células no tecido neoformado. Foram utilizados 18 cães, separados em três grupos de seis, e de cada animal foram colhidas células da medula óssea (MO), contadas e analisadas para morfometria, através da contagem manual e mielograma. Um defeito ósseo tibial foi então criado cirurgicamente, e a lesão tratada com esponja de gelatina embebida em solução fisiológica (G1), esponja de gelatina embebida com aspirado de medula óssea processado (G2) e esponja de gelatina embebida com aspirado de MO processado e proteína óssea morfogenética (G3). A cicatrização foi então avaliada por estudos radiográficos e a presença de CTM foi identificada através de marcadores nanocristais Qtracker em microscopia com luz fluorescente uma semana após a intervenção cirúrgica. Entre as células identificadas pelo marcador, foram encontradas células da linhagem óssea. As avaliações radiográficas demonstram crescimento ósseo acelerado nos grupos G2 e G3, e estatisticamente houve diferenças significativas entre o G1 e G3 em todos os tempos estudados e entre G1 e G2 nos tempos de 30 e 45 dias. A utilização de células-tronco mononucleares adultas suplementadas ou não com rhBMP-2 são alternativas favoráveis ao crescimento ósseo em defeitos experimentais agudos de tíbia de cães.
54

Caracterização do ciclo da marcha em amputado transtibial com prótese inteligente / Gait cycle characterization in transtibial amputation with intelligent prosthesis

Moreira, Fabiano Marques 16 March 2016 (has links)
FINEP; CAPES; CNPQ; Fundação Araucária; ANEEL / O presente trabalho apresenta uma aplicação de sensores à fibra ótica baseados em redes de Bragg encapsulados em compósito de resina polimérica com reforço de fibra de vidro no formato de tubo. O objetivo do trabalho foi projetar, fabricar e caracterizar o dispositivo sensor aplicado ao ciclo da marcha e a mudança do centro de gravidade em amputado transtibial, através da análise de de deformação e resistência do tubo conector da prótese transtibial. Para essa investigação foi produzido um tubo com o material compósito descrito anteriormente através do método de Moldagem por Transferência de Resina (RTM), com quatro sensores óticos. A prótese em que o tubo original foi substituído é classificada como endoesquelético, possui encaixe à vácuo, tem o tubo conector de alumínio e pé com amortecimento de fibra de carbono. O voluntário para os testes foi um homem de 41 anos, 1,65 metros de altura, 72 quilogramas e canhoto. Sua amputação ocorreu devido a trauma (secção cirúrgica nível medial feita abaixo do joelho do membro inferior esquerdo). Ele é usuário de prótese transtibial há dois anos e oito meses A caracterização dos sensores óticos e análise da deformação mecânica e resistência do tubo deu-se pelo ciclo da marcha e a variação do centro de gravidade do corpo através dos seguintes testes: levantar-se, apoiar na perna sem a prótese, apoiar na perna com a prótese, locomoção para frente e locomoção para trás. Os resultados mostram além da caracterização do ciclo da marcha em um amputado transtibial, também um elevado grau de integração das FBGs no compósito e uma alta resistência mecânica do material. / This work presents an application of optical fiber sensors based on Bragg gratings integrated to a transtibial prosthesis tube manufactured with a polymeric composite systrem of epoxy resin reinforced with glass fiber. The main objective of this study is to characterize the sensors applied to the gait cycle and changes in the gravity center of a transtibial amputee, trough the analysis of deformation and strengh of the transtibial prosthesis tube. For this investigation it is produced a tube of the composite material described above using the molding method of resin transfer (RTM) with four optical sensors. The prosthesis in which the original tube is replaced is classified as endoskeletal, has vacuum fitting, aluminium conector tube and carbon fiber foot cushioning. The volunteer for the tests was a man of 41 years old, 1.65 meters tall, 72 kilograms and left-handed. His amputation occurred due to trauma (surgical section is in the medial level, and was made below the left lower limb knee). He has been a transtibial prosthesis user for two years and eight months. The characterization of the optical sensors and analysis of mechanical deformation and tube resistance occurred through the gait cycle and the variation of the center of gravity of the body by the following tests: stand up, support leg without the prosthesis, support in the leg with the prosthesis, walk forward and walk backward. Besides the characterization of optical sensors during the gait cycle and the variation of the gravity center in a transtibial amputated, the results also showed a high degree of integration of the sensors in the composite and a high mechanical strength of the material.
55

Fixador esquelético externo circular para o tratamento de fraturas rádio e tíbia em cães

Gonzalez, Paula Cristina Sieczkowski January 2013 (has links)
O fixador esquelético externo circular foi desenvolvido durante a guerra fria na Rússia, pelo Professor Gavril Abramovich Ilizarov. Esse tipo de fixação ganhou espaço como alternativa à fixação interna, devido a sua versatilidade e às suas características biomecânicas que otimizam a formação do calo ósseo. O objetivo desse estudo foi avaliar o fixador esquelético externo circular como método de fixação para fraturas metafisárias de rádio e tíbia de cães atendidos no Hospital de Clínicas Veterinárias da UFRGS. Os resultados a respeito do tipo e frequência de complicações associados a essa técnica foram documentados. No total 16 animais cumpriram os critérios para entrar no estudo sendo sete fêmeas e nove machos. A idade média dos animais foi de 50,87 ± 57,01 meses com peso médio dos animais foi de 8,6 ± 6,95kg. Três (18%) animais apresentaram fratura de tíbia e fíbula e treze (82%) fraturas de rádio e ulna. O aparelho de fixação esquelética utilizado consistiu de um aro proximal 5/8 e dois aros distais inteiros, com dois fios em cada anel. Os fios foram colocados de maneira divergente o mais próximo possível de 90°. O aparelho pesou em média 128 ± 49g, representando em média 4,09 ± 3,22% do peso do animal. O tempo médio de cirurgia foi de 115 ± 32 minutos. O tempo médio de permanência com o aparelho de fixação esquelética externa circular foi de 81,69 ± 23,14 dias. Entre as complicações encontradas estão: tratos de drenagem ao redor dos fios (37,5%), miíase (6,25%), encurtamento dos músculos flexores do antebraço (6,25%), hemorragia associada ao local de passagens dos pinos (6,25%) e quebra do fio com deslocamento do fixador levando a necessidade de sua remoção (6,25%). Não houve diferença estatística entre os tempos cirúrgicos necessários para a osteossíntese de rádio e tíbia. Não houve correlação entre as variáveis: tempo decorrido do trauma até a cirurgia e tempo de duração da cirurgia; tempo decorrido do trauma até a cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular; peso do animal e duração da cirurgia; proporção do peso do circular em relação ao peso do animal e o tempo de permanecia com o circular. Houve correlação positiva estatisticamente significativa entre as variáveis: duração da cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular. Essa modalidade de tratamento representa uma opção cirúrgica atrativa para a correção de fraturas de rádio e tíbia em cães, entretanto, devido à possibilidade complicações e necessidade de cuidados pós-operatórios intensivos uma seleção acurada dos pacientes e proprietários deve ser realizada previamente à cirurgia. / The circular external skeletal fixator was developed during the Cold War in Russia, by Professor Gavril Abramovich Ilizarov. This kind of fixation took place as an alternative to internal fixation, due to its versatility and its biomechanical characteristics that improves the formation of callus. The aim of this study was to evaluate the circular external skeletal fixator as a method of fixation for fractures of the radius and tibia of dogs treated at the Veterinary Teaching Hospital of UFRGS, corroborating the results, the type and frequency of complications associated with this technique. Sixteen animals met the criteria to participate on the study, seven females and nine males. The average age of the animals was 50.87 ± 57.01 months. The average weight of the animals was 8.6 ± 6.95 kg. Three (18%) animals showed fracture of tibia and fibula and thirteen (82%) fractures of the radius and ulna. The circular external skeletal fixation frame used consisted of a proximal ring ⅝ and two full distal rings, with two wires in each ring. The wires were placed divergently as close as possible to 90 °. The frame weighed on average 128 ± 49g, representing average 4.09 ± 3.22% of the weight of the animal. The mean time of the surgery was 115 ± 32 minutes. The average time spent with the circular was 81.69 ± 23.14 days. Among the complications found are drainage tracts around the pins (37.5%), myiasis (6.25%), shortening of the forearm flexors (6.25%), hemorrhage associated with the location of pins passages (6, 25%) and breakage of the device wire with displacement of the frame leading to its removal (6.25%). There was no statistical difference between the times required for the surgical fixation of the radius and tibia. There was no correlation between the variables: time elapsed from trauma to surgery and duration of surgery, time elapsed from trauma to surgery and time spent with the circular external skeletal fixation; animal weight and duration of surgery; the proportion of the circular weight in relation to the weight of the animal and the time remained with the circular. There was statistically significant positive correlation between the variables: duration of the surgery and the permanency with the circular external skeletal fixation. This treatment modality represents an attractive surgical option for fractures correction of the radius and tibia in dogs, however, due to possible complications and need for intensive post operative care accurate selection of patients and owners should be performed prior to surgery.
56

Fixador esquelético externo circular para o tratamento de fraturas rádio e tíbia em cães

Gonzalez, Paula Cristina Sieczkowski January 2013 (has links)
O fixador esquelético externo circular foi desenvolvido durante a guerra fria na Rússia, pelo Professor Gavril Abramovich Ilizarov. Esse tipo de fixação ganhou espaço como alternativa à fixação interna, devido a sua versatilidade e às suas características biomecânicas que otimizam a formação do calo ósseo. O objetivo desse estudo foi avaliar o fixador esquelético externo circular como método de fixação para fraturas metafisárias de rádio e tíbia de cães atendidos no Hospital de Clínicas Veterinárias da UFRGS. Os resultados a respeito do tipo e frequência de complicações associados a essa técnica foram documentados. No total 16 animais cumpriram os critérios para entrar no estudo sendo sete fêmeas e nove machos. A idade média dos animais foi de 50,87 ± 57,01 meses com peso médio dos animais foi de 8,6 ± 6,95kg. Três (18%) animais apresentaram fratura de tíbia e fíbula e treze (82%) fraturas de rádio e ulna. O aparelho de fixação esquelética utilizado consistiu de um aro proximal 5/8 e dois aros distais inteiros, com dois fios em cada anel. Os fios foram colocados de maneira divergente o mais próximo possível de 90°. O aparelho pesou em média 128 ± 49g, representando em média 4,09 ± 3,22% do peso do animal. O tempo médio de cirurgia foi de 115 ± 32 minutos. O tempo médio de permanência com o aparelho de fixação esquelética externa circular foi de 81,69 ± 23,14 dias. Entre as complicações encontradas estão: tratos de drenagem ao redor dos fios (37,5%), miíase (6,25%), encurtamento dos músculos flexores do antebraço (6,25%), hemorragia associada ao local de passagens dos pinos (6,25%) e quebra do fio com deslocamento do fixador levando a necessidade de sua remoção (6,25%). Não houve diferença estatística entre os tempos cirúrgicos necessários para a osteossíntese de rádio e tíbia. Não houve correlação entre as variáveis: tempo decorrido do trauma até a cirurgia e tempo de duração da cirurgia; tempo decorrido do trauma até a cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular; peso do animal e duração da cirurgia; proporção do peso do circular em relação ao peso do animal e o tempo de permanecia com o circular. Houve correlação positiva estatisticamente significativa entre as variáveis: duração da cirurgia e tempo de permanência com o aparelho de fixação esquelética externa circular. Essa modalidade de tratamento representa uma opção cirúrgica atrativa para a correção de fraturas de rádio e tíbia em cães, entretanto, devido à possibilidade complicações e necessidade de cuidados pós-operatórios intensivos uma seleção acurada dos pacientes e proprietários deve ser realizada previamente à cirurgia. / The circular external skeletal fixator was developed during the Cold War in Russia, by Professor Gavril Abramovich Ilizarov. This kind of fixation took place as an alternative to internal fixation, due to its versatility and its biomechanical characteristics that improves the formation of callus. The aim of this study was to evaluate the circular external skeletal fixator as a method of fixation for fractures of the radius and tibia of dogs treated at the Veterinary Teaching Hospital of UFRGS, corroborating the results, the type and frequency of complications associated with this technique. Sixteen animals met the criteria to participate on the study, seven females and nine males. The average age of the animals was 50.87 ± 57.01 months. The average weight of the animals was 8.6 ± 6.95 kg. Three (18%) animals showed fracture of tibia and fibula and thirteen (82%) fractures of the radius and ulna. The circular external skeletal fixation frame used consisted of a proximal ring ⅝ and two full distal rings, with two wires in each ring. The wires were placed divergently as close as possible to 90 °. The frame weighed on average 128 ± 49g, representing average 4.09 ± 3.22% of the weight of the animal. The mean time of the surgery was 115 ± 32 minutes. The average time spent with the circular was 81.69 ± 23.14 days. Among the complications found are drainage tracts around the pins (37.5%), myiasis (6.25%), shortening of the forearm flexors (6.25%), hemorrhage associated with the location of pins passages (6, 25%) and breakage of the device wire with displacement of the frame leading to its removal (6.25%). There was no statistical difference between the times required for the surgical fixation of the radius and tibia. There was no correlation between the variables: time elapsed from trauma to surgery and duration of surgery, time elapsed from trauma to surgery and time spent with the circular external skeletal fixation; animal weight and duration of surgery; the proportion of the circular weight in relation to the weight of the animal and the time remained with the circular. There was statistically significant positive correlation between the variables: duration of the surgery and the permanency with the circular external skeletal fixation. This treatment modality represents an attractive surgical option for fractures correction of the radius and tibia in dogs, however, due to possible complications and need for intensive post operative care accurate selection of patients and owners should be performed prior to surgery.
57

Efeitos da infusão de Heteropterys aphrodisiaca (O.Mach) associada ao treinamento fisico no sistema musculoesqueletico de ratos Wistar / Effect of Heteropterys aphrodisiaca infusion associated with endurance training on the muscle-skeletal system of Wistar rats

Monteiro, Juliana Castro 15 August 2018 (has links)
Orientador: Mary Anne Heidi Dolder / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-15T21:18:52Z (GMT). No. of bitstreams: 1 Monteiro_JulianaCastro_D.pdf: 3195959 bytes, checksum: df90aa1ceb6206d4b8d1a040083df0c7 (MD5) Previous issue date: 2010 / Resumo: Este estudo investigou os efeitos da infusão de Heteropterys aphrodisiaca no músculo esquelético, tendão e osso de ratos submetidos ao treinamento de endurance. Ratos Wistar machos foram agrupados da seguinte maneira: CS-controle sedentário, HS-H. aphrodisiaca sedentário, CT-controle treinado, HT-H. aphrodisiaca treinado. O protocolo de treinamento consistiu de corrida em esteira motorizada, cinco vezes por semana, com aumento semanal de velocidade e duração. Os animais dos grupos controle receberam água, enquanto HS e HT receberam infusão de H. aphrodisiaca, diariamente, por gavagem durante 8 semanas, correspondente ao período de treinamento. O sangue foi coletado para dosagem de testosterona. O músculo extensor longo dos dedos (EDL), tendão calcanear e a tíbia foram congelados para análises histoquímicas, bioquímicas, biomecânicas e para Western Blot, ou preservados em fixador Karnovsky, sendo posteriormente processados para análises morfométricas e estereológicas utilizando microscopia de luz e eletrônica. O conteúdo de hidroxiprolina, a tensão máxima e o módulo de elasticidade aumentaram (p<0,05) nos tendões dos animais do grupo HT. A atividade da metalopeptidase-2 foi reduzida significativamente nos tendões dos animais do grupo HT. A região de compressão dos tendões dos animais do grupo HT apresentou intensa metacromasia, o que sugere aumento na concentração de glicosaminoglicanos nessa região tendão. Foi observada intensa birrefringência nas regiões de tensão e compressão dos tendões dos animais do grupo HT, o que pode indicar maior nível de organização dos feixes de colágeno. Os níveis de testosterona plasmáticos e a concentração de receptores de andrógeno no músculo esquelético aumentaram significativamente nos animais do grupo HS. A área média de secção transversa das fibras musculares dos animais do grupo HT foi semelhante à área das fibras dos animais sedentários, e aumentou significativamente quando comparados com os animais do grupo CT. A vascularização intramuscular e a densidade volumétrica de mitocôndria foram significativamente maiores nos animais do grupo HT. Nenhuma alteração foi observada nos tipos de fibras musculares para todos os grupos. Os animais do grupo HT mostraram significativo aumento de força e tensão no limite elástico durante o teste biomecânico da tíbia. O conteúdo de colágeno e os dados morfométricos da tíbia não foram alterados nos diferentes grupos. A força e tensão máxima, rigidez e módulo de elasticidade da tíbia foram semelhantes em todos os grupos experimentais. As microscopia eletrônica de varredura mostrou aumento de lacunas e canais de Havers nos ossos dos animais treinados, além disso, os ósteons estavam mais desorganizados quando comparados com os ossos dos animais sedentários. Essas alterações podem indicar que os ossos dos animais treinados estavam sendo remodelados. Portanto, com oito semanas de treinamento não foi possível verificar alterações nas medidas morfométricas, composição e nas propriedades mecânicas (rigidez e módulo de elasticidade) dos ossos dos animais treinados e/ou tratados com a infusão da planta. Por outro lado, a associação do treinamento de endurance com H. aphorodisiaca resultou em tendões mais resistentes para suportar as altas cargas geradas pelas contradições musculares repetidas, aumentou a área de secção transversa das fibras musculares, a densidade volumétrica de mitocôndrias e a vascularização do músculo, assim, sugerindo um aumento da capacidade de endurance dos animais. / Abstract: This study investigated the effects of Heteropterys aphrodisiaca infusion on the skeletal muscle, tendon and bone of rats under endurance training. Male Wistar rats were grouped as follows: CS- control sedentary, HS- H. aphrodisiaca sedentary , CT-control trained, HT- H. aphrodisiaca trained. The training protocol consisted in running on a motorized treadmill, five times a week, with weekly increase in treadmill velocity and duration. Control groups received water while the HS and HT groups received H. aphrodisiaca infusion, daily, by gavage for the 8 weeks of training. The blood was collected for testosterone dosage. Extensor digitorum longus (EDL) muscle, Achilles tendons and tibiae were frozen for histochemical, Western Blotting, biochemical and biomechanical analylis or preserved in Karnovsky's fixative, then processed for morphological analysis by light microscopy and electron microscopy. Biomechanical analysis showed significant increase (p<0.05) in maximum stress and modulus of elasticity of the tendons of the HT animal. The metalloproteinase-2 activity was reduced in the HT tendons. The compression region of tendons of HT animals had a stronger and more intense metachromasy, which suggests increase in glycosaminoglycan concentration in this region of the tendon. The most intense birefringence was observed in both compression and tesion regions of the tendon of HT animals, which may indicate a higher organizational level of collagen bundles. The tendon hidroxyproline content increased significantly is HS animals. The EDL mean cross-section area of HT group was similar to sedentary groups and increased significantly when compared with CT group. The intramuscular vascularization and mitochondria volume density were significantly greater in the HT group compared with other groups. No alterations were observed in the muscle fiber composition for all groups. The HT group showed significantly higher yield load and yield stress in the tibiae three-point bending test. The tibiae collagen content, morphometrical data were not significantly different for the four groups. The maximum load, stiffness, maximum stress and elastic modulus were statistically similar for all for the experimental groups. Scanning electron microscopy showed more lacunae and Havers canals in the bone of trained animals, moreover the osteons were more disorganized, when compared with sedentary groups. These alterations may indicate that the bone of trained animals was being remodeled. Possibly, the duration of training in this study was not sufficient to alter the bone morphometrical measurements, composition and mechanical properties (stiffness and modulus of elasticity) of the trained and treated animals. On the other hand, the association of endurance training with H. aphrodisiaca resulted in more resistant tendons to support high loads from repeated muscle contraction. Also, the association of H. aphrodisiacaI and the exercise protocol increased the mean area of muscle fiber, mitochondrial volume density and muscular vascularization , suggesting an increase of the endurance capacity of these animals. / Doutorado / Biologia Celular / Doutor em Biologia Celular e Estrutural
58

Análise isocinética do tornozelo e das forças de reação de solo em corredores de longa distância e triatletas / Ankle isokinetic analysis and ground reaction forces of long distance runners and triathletes

Natalia Mariana Silva Luna 15 December 2010 (has links)
Introdução: A associação da fadiga muscular com o aumento da força vertical de reação do solo representa risco para a fratura por estresse de tíbia em esportes como a corrida de longa distância e o triatlo. Objetivos: analisar e comparar parâmetros do componente vertical das forças de reação do solo e parâmetros musculares isocinéticos da flexão-plantar (FP) e dorsiflexão (DF) do tornozelo entre corredores de longa distância, triatletas e indivíduos não-atletas. Materiais e Métodos: foram avaliados 75 indivíduos do sexo masculino, divididos em: Grupo Triatleta (GT) (n=26), Grupo Corredores de Longa Distância (GCL) (n=26) e Grupo Controle de não- atletas (GC) (n=23). Para avaliação da força vertical foi utilizada uma plataforma de força, onde os indivíduos realizaram passos de corrida em uma distância pré-determinada. Foram coletados dez passos (cinco com o membro direito e cinco com o esquerdo). A avaliação isocinética foi realizada no modo concêntrico/excêntrico e excêntrico/concêntrico da flexão-plantar (FP) e dorsiflexão (DF) do tornozelo direito e esquerdo. Foram feitas cinco repetições na velocidade de 60º/s e 30 repetições a 180º/s, com repouso de 10 segundos entre as séries. Resultados: O GC e o GT apresentaram forças verticais menores e maior tempo de contato com o solo e de aplicação da força na aceleração vertical máxima que o GCL. O tempo de aplicação de força foi maior no GC que o GT. A avaliação isocinética (180º/s) mostrou: maiores valores da DF excêntrica e FP concêntrica no GC e GT quando comparados com o GCL; maiores valores para DF concêntrica no GC comparado do GT e GCL e GT maior GCL; TA foi maior na DF excêntrica do GCL que GC; a maior relação agonista-antagonista FP e DF foi no modo concêntrico-excêntrico do GC quando comparado com GT e GCL. Na avaliação a 60º/s, maior PT durante a FP excêntrica e DF concêntrica no GC que GT e GCL e maior FP concêntrica no GT e GC. Conclusões: Os atletas mostraram menor força e resistência isocinéticas e maiores valores de impacto que os controles. Os triatletas tiveram menor impacto e melhor desempenho na variável de resistência muscular. / Introduction: The association of fatigue with increasing vertical force of ground reaction represent a risk for Tibial stress fracture in sports like long distance running and triathlon. Objectives: To analyze and compare the parameters of the vertical component of ground reaction forces and the parameters of muscle isokinetic ankle flexion-plantar (PF) and dorsiflexion (DF) among long distance runners, triathletes and non-athletes. Materials and Methods: total of 75 males, divided into three groups: Triathletes (GT) (n=26), Long Distance Runners (GR) (n=23) and nonathletes Controls (GC) (n=26) participated in the study. The force platform were used to record vertical forces and the subjects were instructed to perform race steps for a predetermined distance and to complete ten practical experience (five with the right limb and five with the left), which consisted of consistent landing from one of his feet in the center of the platform. The isokinetic evaluation was performed in the concentric/eccentric and eccentric/concentric ankle plantar-flexion (PF) and dorsiflexion (DF) (60°/s and 180°/s). Results:The GC and GT showed lower vertical forces, increased total time ground support and time of application of force at maximum vertical acceleration than GR. In this last variable, the GC had a time of application of force even greater than GT. To isokinetic evaluation at 180 ° / s, GT and GC presented TW significantly higher than GR, during DF eccentric and PF concentric; in DF concentric, the GC was higher than GR and GT and GT higher than GR; GR presented TA significantly higher than GT and GC, during DF eccentric; GC presented agonist-antagonist ratio for PF and DF in the concentriceccentric mode, higher than GT and GCL. For evaluation at 60 °/s, the GC presented s PT significantly higher than GT and GR, during PF eccentric and DF concentric; FP concentric GC higher than GT. Conclusions: The athletes presented lower isokinetics strength and endurance and higher impact values than the controls. The triathletes had less impact and better performance in variable muscular endurance.
59

Retalho súpero-lateral da perna: descrição anatômica e aplicação clínica de um novo retalho / The superolateral leg flap: an anatomical study and clinical applications of a new flap

Teng Hsiang Wei 08 August 2006 (has links)
O autor realizou um estudo anatômico da região lateral e proximal da perna por meio de dissecção anatômica em cadáver, de exame arteriográfico e de mapeamento com Doppler em pacientes, visando a descrição da artéria denominada fibular superior, que se origina no tronco tíbio-fibular em 70% dos casos, da artéria fibular, em 20% e da artéria tibial anterior, em 10% e participa na irrigação do músculo sóleo e gastrocnêmio. Este vaso possui características adequadas para a realização de micro-anastomose. Após a conclusão da parte anatômica-descritiva, o autor aplicou o retalho derivado da artéria fibular superior, denominado retalho súpero-lateral da perna, na reconstrução de defeitos cutâneos e defeitos complexos tridimensionais, localizados no pé e tornozelo, em 10 pacientes, obtendo bons resultados / The author performed an anatomical study of the proximal and lateral aspect of the leg, consisting of cadaver dissection, arteriogram and Doppler mapping, in order to disclose the features of a new vessel, denominated superior peroneal artery. It originates from the tibiofibular trunk in 70 % of times, from the peroneal artery, 20%, and from the anterior tibial artery, 10%. It contributes to nourish the soleous and the lateral gastrocnemius muscle. The superior peroneal vessels are also suitable for microanastomosis. Therefore, the flap derived from the superior peroneal artery, called superolateral leg flap (SLL), was used for lower leg reconstructions in 10 patients, in two of them as chimeric flap for complex tridimensional defects, with good results
60

"Análise das propriedades biomecânicas dos tendões dos músculos tibial anterior e tibial posterior : estudo experimental em cadáveres humanos" / Biomechanical analysis of anterior and posterior tibialis tendons : experimental study in human cadavers

Viegas, Alexandre de Christo 08 May 2003 (has links)
O autor estudou as propriedades biomecânicas dos tendões dos músculos tibial anterior e tibial posterior congelados a -20°C e a -86°C extraídos de cadáveres humanos frescos. Foram realizados ensaios mecânicos de tração até a ruptura e determinadas as seguintes propriedades: resistência máxima, coeficiente de rigidez, módulo de elasticidade e alongamento máximo relativo. Os dados obtidos foram comparados aos existentes na literatura relativos ao ligamento cruzado anterior, ligamento da patela e aos tendões dos músculos grácil e semitendíneo / The author studied the mechanical properties of the anterior and posterior tibialis muscle tendons frozen at -20°C and -86°C obtained from fresh-frozen human cadavers. The tendons were submitted to axial traction until failure and the following properties were determined: ultimate load, stiffness, modulus of elasticity and relative strain. Data obtained were compared to those from the literature related to the anterior cruciate ligament, patellar tendon, gracilis and semitendinous tendons

Page generated in 0.2619 seconds