• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1015
  • 29
  • 28
  • 28
  • 28
  • 27
  • 17
  • 11
  • 5
  • 4
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1068
  • 564
  • 280
  • 216
  • 190
  • 129
  • 127
  • 111
  • 103
  • 97
  • 89
  • 87
  • 81
  • 77
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Projecto de câmara para fusão de ligas reactivas com cadinho frio

Silva, Luís Pedro Freitas da 21 February 2014 (has links)
Documento confidencial. Não pode ser disponibilizado para consulta / Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
262

Desenvolvimento e otimização de materiais nanocristalinos para células solares sensibilizadas

Trino, Luciana Daniele [UNESP] 17 February 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-17Bitstream added on 2014-08-13T18:01:35Z : No. of bitstreams: 1 000744019.pdf: 2471053 bytes, checksum: d8143f4bf876872ec3917c9172aa9624 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Considerando a crescente demanda por energia elétrica e as mudanças ambientais causadas pela utilização de fontes energéticas não renováveis, a energia solar apresenta-se como uma boa alternativa aos combustíveis fósseis. Dentre os dispositivos fotovoltaicos, as células solares sensibilizadas (DSSC's) utilizam materiais abundantes na natureza e de baixo custo. No entando, é necessário um aperfeiçoamento das mesmas para aumentar sua eficiência e torná-las comercializáveis. Para se obter uma boa eficiência no dispositivo, é também essencial um controle das propriedades estruturais e ópticas dos semicondutores empregados. Nestes dispositivos, o dióxidode titânio é utlizado como semicondutor nas DSSC's por possuir um band gap larg que absorve luz em comprimentos de onda capazes de gerar pares elétron-buraco. Já o óxido de zinco é empregado como óxido semicondutor transparente por apresentar alto grau de transmitância optica. Filmes finos de TiO2 e ZnO foram sintetizados pela técnica sol-gel e depositadas por spin-coating em substratos de vidro com a finalidade de estudar as condições de deposição e investigar suas propriedades estruturais e ópticas. Os espécimes preparados foram caracterizados por difração de raios X, microscopia eletrônica de varredura, microscopia óptica confocal, microscopia de força atômica e espectroscopia na região do UV-Vis. As análises estruturais mostraram que a concentração de surfactante, os parâmetros de deposição dos filmes e as temperaturas de tratamento térmico empregadas têm grande influência sobre algumas propriedades dos filmes, sedo estas a aderência dos filmes no substrato vítreo, a fase cristalina formada, o tamanho de partícula e a uniformidade superficial dos filmes. Os estudos ópticos dos filmes de ZnO apresentaram um valor de band gap em acordo com os da literatura (3,3 e V) transmitância acima de 80%. Já os filmes de TiO2 apresentaram absorção em... / Considering the rising demand for electricity and the environmental changes caused by the use of non-renewable energy sources, solar energy is presented as a good alternative to fossil fuels. Among the photovoltaic devides, dye sensitized solar cells (DSSC'S) use abundant in nature and low cost materials. Nevertheless, is necessary to improve the DSSC's by increasing their efficiency and making them marketable. To obtain a good efficiency in the device, it is also essential to control the structural and optical properties of the semiconductors employed. In these devices, the titanium dioxide is used as a semiconductor presenting a wide band-gap which absorbs light at wavelengths capable of genertaing electron-hole pairs. Zinc oxide is applied as a transparent conductor oxide which has high optical transmittance. Thin films of TiO2 and ZnO were synthesized by sol-gel route and deposited by spin-coating technique on glassy substrate in order to study the deposition conditions and investigate their structural and optical properties. The specimes were characterized by X-ray diffraction, scanning electron microscopy, confocal optical microscopy, atomic force microscopy and spectroscopyin the UV-Vis. Structural analysis showed that the surfactant concentration, the parameters of the film deposition and the heat treament temperatures employed had a major influence on the adhesion of the films at the glassy substrate, on the crystal phase formed, on the particle size and on the homegeneity of the film surface. The optical studies of ZnO showed a band gap value consistent with the literature (3.3 eV) and transmittance above 80%. TiO2 films exchibited absorption around 400 nm a high gap for the anatase crystalline phase of 4.1 eV, due to the presence of brookite phase. TiO2-ZnO films presented the same values for TiO2 films of 4.1 eV
263

Avaliação in vitro da adesão de fibroblastos NIH3T3 estimulados por bFGF em discos de titânio

Thaddeu, Camilo Santos January 2008 (has links)
Made available in DSpace on 2013-08-07T18:42:01Z (GMT). No. of bitstreams: 1 000399015-Texto+Parcial-0.pdf: 142110 bytes, checksum: c5ffb33c81a7c9cbade03c8428376c8e (MD5) Previous issue date: 2008 / A estable connection between the titanium surface and the surrounding tissue is the most important prerequisites for the long-term success of implants. Therefore, a strong adhesion of the cells on biomaterial surface is required. The objective of this study was to evaluate fibroblast adhesion stimulated by basic Fibrobast Growth Factor (bFGF) on titanium discs. For this study 30 titanium discs with smooth surface were produced. These discs were placed on culture plates with NIH3T3 fibroblasts, stimulated by bFGF, on test group and without the growth factor on control group. The samples were obtained after 3 hours, 24 hours and 48 hours. Using SEM, 10 images were obtained from each disc, totalizing 300 micrografies. The test showed that there are more fibroblasts attached to titanium discs, with a significative difference, at all experimental analysed periods of this experiment, when bFGF was administrated. / Uma conexão estável entre a superfície de titânio e os tecidos a sua volta é um dos mais importantes pré-requisitos para o sucesso a longo prazo dos implantes. Para isso, uma forte e efetiva adesão das células na superfície do biomaterial é requerida. O objetivo desse estudo foi o de avaliar a adesão de fibroblastos estimulados por Fator de Crescimento de Fibroblastos básico (bFGF) em discos de titânio. Para esse estudo foram produzidos 30 discos de titânio com superfície lisa. Esses discos foram colocados em placas de cultura e sobre eles foi inserido meio com fibroblastos NIH3T3, estimulados por bFGF, no grupo teste e sem este fator de crescimento no controle. As amostras foram obtidas em 3 horas, 24 horas e 48 horas. Foram feitas 10 imagens com Microscópio Eletrônico de Varredura em cada disco, totalizando 300 micrografias. Como resultado foi encontrado que existe uma diferença significativa no crescimento de fibroblastos nos três tempos deste experimento, do grupo onde o bFGF foi administrado.
264

Análise in vivo da modulação óssea em implantes de titânio com superfície em nanoescala / Analysis in vivo of bone modulation in titanium implants with nanoscale surface

Carvalho, Lais Morandini 20 November 2017 (has links)
Submitted by LAÍS MORANDINI CARVALHO null (lais_morandini@yahoo.com.br) on 2018-01-03T14:22:11Z No. of bitstreams: 1 Lais Morandini Carvalho.pdf: 3515290 bytes, checksum: b29a2f58afa414dd9e9f4df531340ca2 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-04T18:53:50Z (GMT) No. of bitstreams: 1 Carvalho_lm_dr_sjc.pdf: 3515290 bytes, checksum: b29a2f58afa414dd9e9f4df531340ca2 (MD5) / Made available in DSpace on 2018-01-04T18:53:50Z (GMT). No. of bitstreams: 1 Carvalho_lm_dr_sjc.pdf: 3515290 bytes, checksum: b29a2f58afa414dd9e9f4df531340ca2 (MD5) Previous issue date: 2017-11-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nas últimas décadas houve um aumento considerável na utilização dos implantes metálicos para aplicações na área da ortopedia e odontologia, por isso as pesquisas têm como foco estudar os mecanismos biológicos de interação osso-implante. A nanotopografia de superfície de implantes osseointegráveis apresenta efeito direto sobre a resposta biológica óssea. No entanto a maneira como afeta a osseointegração in vivo ainda não está totalmente elucidada. O objetivo neste estudo foi comparar in vivo a influência da superfície em nanoescala (nano) confeccionada em implantes de titânio comercialmente puro (Ticp), comparado-a a superfície lisa (controle) em modelo experimental de camundongos osterix-mcherry (Osx-mcherry), os quais expressam proteína fluorescente concomitante com a expressão do gene osterix (Osx). Os animais receberam implantes de superfície lisa no fêmur direito e com nanoescala no fêmur esquerdo. Após diferentes períodos de eutanásia baseados na metodologia empregada foram realizados nas peças e nas células os seguintes testes biológicos: microscopia eletrônica de varredura (MEV) para avaliação da adesão celular e da superfície do implante; histologia e nanotomografia (nanoCT) para observação e quantificação de osso neoformado na interface osso/implante; citometria de fluxo para quantificação de células marcadas pelo gene osterix; PCR em tempo real (qPCR) para avaliação da expressão gênica; coloração fosfatase ácida resistente ao tartarato (TRAP) para contagem de osteoclastos. Nossos resultados mostraram que a maioria dos genes estudados estavam superexpressos nas amostras com superfície em nanoescala sendo que alguns deles apresentaram diferenças estatísticas (Teste t, p < 0.05), tais como: Osx (osterix), Alp (fosfatase alcalina), Prx1(homeobox relacionado emparelhado -1), Dmp1 (Dolicol-fosfatase mannosiltransferase subunidade 1), Bsp (sialoproteína óssea) e Ocn (osteocalcina). Os testes estatísticos ANOVA two way seguido do Teste de Tukey quando necessário, foram utilizados para os demais experimentos e o nível de significância foi estabelecido em p < 0.05. Diferenças estatísticas foram encontradas para o nanoCT e histologia entre as superfícies e períodos avaliados e os melhores resultados foram observados para a nanoescala. A coloração TRAP também mostrou diferenças estatísticas entre as superfícies e períodos estudados, com a superfície lisa mostrando melhores resultados aos 3 dias e a nano aos 5 e 7 dias. Não houve diferença estatística para a citometria de fluxo, porém a superfície em nanoescala mostrou melhores resultados que a lisa em todos os períodos analisados. Concluímos que a superfície em nanoescala possui propriedades osteocondutivas e favorece os eventos biológicos que ocorrem na superfície do implante melhorando o processo de osseointegração.
265

Caracterização térmica e mecânica de cerâmicas porosas com camadas de TiO2 e Al2O3

Costa, David Julio da [UNESP] 04 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-04Bitstream added on 2014-06-13T20:37:38Z : No. of bitstreams: 1 costa_dj_me_guara.pdf: 959258 bytes, checksum: 07963064751da13bd2ff1173cba566ee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo a obtenção de pastilhas cerâmicas Al2O3/TiO2 e as caracterizações térmica e mecânica das camadas destas pastilhas. As pastilhas foram obtidas pelos processos de conformação direta com amido comercial e por prensagem. Nesta dissertação são apresentados os moldes metálicos e de polímeros para confecção dos corpos de prova para o ensaio mecânico de resistência à flexão, e para o ensaio térmico à flexão seguiram a norma ASTM C1161. Na caracterização térmica, é analisado o coeficiente de expansão térmica. na caracterização mecânica, são analisados a reistência mecânica à flexão e o valor da flecha de deformação do corpo de prova. Verificou-se que a aplicação de um gradiente de porosidade reduz as tensões residuais térmicas na pastilha. / This work aimed the acquisition of Al2O2/TiO2 ceramic wafers and their thermal and mechanical characterization. The wafers have been obtained by starch consolidation process and pressing. In this dissertation are presented metallic and polymeric moulds to obtain the samples for mechanical and thermal tests. Mechanical tests of flexural mechanical strength and thermal tests of dilation have been achieved. The measurements of the samples for flexural mechanical strenth testing followed the ASTM C1161 standard. The thermal dilation coefficient is analyzed in the thermal characterization. In the mechanical characterization are analysed the flexural mechanical strenght and the maximum deformation arrow of the samples. A reduction of the residual thermal stresses by aplication of a gradient of porous has been verified.
266

Oxidação fotoeletrocatalítica de glicose a compostos orgânicos com maior valor agregado empregando fotoeletrodos de nanotubos de dióxido de titânio /

Fabrão, Rodrigo Monteiro. January 2016 (has links)
Orientador: Maria Valnice Boldrin Zanoni / Banca: Maria Aparecida Zaghete Bertochi / Banca: Germano Tremiliosi Filho / Resumo: A produção de etanol e açúcar a partir de cana-de-açúcar é um atividade de grande importância no Brasil, mas também fonte de grande preocupação ambiental devido ao grande acúmulo de biomassa na forma de bagaço e vinhaça gerados como rejeitos. A biomassa lignocelulósica é constituída de celulose, com estrutura formada de unidades de glicose polimerizadas, deste modo estudos voltados para a conversão de glicose em compostos químicos com maior valor agregado seria relevante para buscar novas formas de aproveitamento destes rejeitos. O objetivo do presente trabalho é investigar a aplicabilidade da técnica de fotoeletrocatálise para promover a oxidação de glicose em meio aquoso utilizando nanotubos de dióxido de titânio (NT-Ti/TiO2) como fotoanodos com vistas a obtenção de compostos com maior valor agregado. Os eletrodos de nanotubos de dióxido de titânio (NT-Ti/TiO2) foram preparados por oxidação eletroquímica de Ti em solução 1,0 mol L-1 de NaH2PO4 + 0,3% (m/m) HF como eletrólito de suporte sob potencial de 20V por 2 h e calcinado a 450 °C. Um método analitico baseado em cromatografia de troca iônica com detecção amperométrica foi desenvolvido para análise de glicose, acido glicônico, acido glicárico, arabitol e arabinose e curvas analíticas foram construídas em concentrações de 1,00 a 20,0x10-6 mol L-1, r = 0,9995, e o método alcançou limites de detecção e determinação ao redor de LD = 0,03x10-6 mol L-1 e LQ = 0,08x10-6 mol L-1 para a determinação de glicose. O ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The production of sugar and ethanol from sugarcane is an activity very important in Brazil, but it is also a source of great environmental concern due to the large accumulation of biomass in form of bagasse and vinasse generated as waste of this process. The lignocellulosic biomass is made up of cellulose, wich structure is made of polymerized glucose units. Thereby studies focused on the conversion of glucose into added value chemical compounds would be relevant to seek new ways to use these waste. This work describes the construction electrodes of titanium dioxide nanotubes (NT-Ti / TiO2) and its application in photoeletrocatalytic oxidation of glucose in aqueous media aimed at converting glucose into compounds with higher added value. The electrodes were prepared by electrochemical oxidation of Ti in solution of 1.0 mol L-1 NaH2PO4 + 0.3% (m/m) HF as supporting electrolyte under a potential of 20V for 2 h and calcined at 450 ° C. An analytical method based on ion exchange chromatography with amperometric detection was developed for glucose, gluconic acid, glucarico acid, arabitol and Arabinose analysis and analytical curves were constructed at concentrations of 1.00 to 20,0x10-5 mol L-1, r = 0.9995, and the method achieved detection limits and determination around 0,03x10-6 mol L-1 and 0,08x10-6 mol L-1 for glucose determination, respectively. The method was used for monitoring the generated products due the oxidation photoeletrocatalytic 10.0 mmol L-1 glucose solution und... (Complete abstract click electronic access below) / Mestre
267

Análise de corrosão, dureza e fratura de conjuntos implantes / componentes protético de Titânio c.p., após serem submetidos a ciclos de fadiga em um meio fluoretado com diferentes PH /

Vaz, Luis Geraldo. January 2007 (has links)
Resumo: Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas. / Abstract: Titanium has been widely used as biomaterial owing to its excellent corrosion resistance, mechanical properties and biocompatibility. However, it has been reported that fluoride-containing environments can attack titanium. The aim of this study was evaluated fluoride environments influence with different pH values in the implant/abutment sets. The implants were separated into 3 groups containing 7 implants/brand: one was submerged in acid fluoride environment (NaF 1500ppm 184h pH 5.3), one in neutral fluoride environment (NaF 1500ppm 184h pH 7.4), and other group in distillated water, simulating five years of dental hygiene. Hardness and surface texture were evaluated before and after fluoride exposition by Vickers method (500gf/30s) and scanning electron microscopy (SEM), respectively. The fatigue test was performed with 100.000 load cycles, 15 Hz and 150 N. There was decrease in hardness in implants submitted to the fluoride environment. SEM and EDS evaluation showed dark stains in all implants, irrespective of fluoride pH, resulting from pitting corrosion process. All sets supported the fatigue test until 100.000 load cycles. The results demonstrated that fluoride environment there was no influence in mechanical properties of the implant/abutment sets.
268

Estudo in vitro da interação de titânio irradiado por feixe de laser Yb:YAG com e sem recobrimento de apatitas, empregando-se cultura de células estaminais humanas /

Tavares, Hewerson Santos. January 2009 (has links)
Resumo: Superfícies de titânio apresentam importantes propriedades físico-químicas e morfológicas com aplicações em muitos dispositivos que requerem interação com o tecido ósseo. O objetivo do presente estudo foi avaliar in vitro utilizando-se cultura de células estaminais a interação da superfície de titânio irradiado com laser em menor fluência (L1); laser com maior fluência (L2) e superfície L2 com recobrimento de apatitas, (HA). A irradiação laser Yb:YAG em diferentes parâmetros ocasionou a formação de óxidos de titânio nas superfícies irradiadas, que podem influenciar diretamente a integração biológica. As superfícies obtidas foram caracterizadas por Microscopia Eletrônica de Varredura (MEV) e Difração de raios X (DRX) e a camada de hidroxiapatita foi avaliada por espectroscopia no infra vermelho transformada de Fourier (FTIR) e medidas de ângulo de contato. As avaliações in vitro foram realizadas utilizando as superfícies L1, L2 e HA diretamente em contato com células humanas indiferenciadas. Os parâmetros biológicos avaliados foram: adesão, proliferação, e metabolismo celular. Foi determinada a concentração de fosfatase alcalina (ALP) e conteúdo total de proteína, produção de osteocalcina e diferenciação osteogênica pela associação das análises. A morfologia celular foi avaliada por MEV, e a micro análise por espectroscopia por energia dispersiva de raios X (EDS) e microscopia de fluorescência. Os resultados indicaram que todos os grupos experimentais apresentaram menor adesão e proliferação celulares nos estágios iniciais em relação ao grupo controle, com aumento da proliferação após 14 dias. Também aos 14 dias houve aumento na taxa de metabolismo celular em todos os grupos experimentais. Os níveis de ALP/Proteína associados aos dados sobre metabolismo celular indicaram sinais bioatividade do grupo HA aos 21 dias. Conclusão:.. (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium surfaces have important physical-chemistry and morphological properties with many applications on biomedical devices whose have bone tissue interaction. The laser beam irradiation on titanium surfaces presented in this study was evaluated by the osseointegration of human mesenchymal stem cells. In this study was performed laser irradiation (Low fluency L1; high fluency L2; high fluency associated apatite treatment HA; and the control group machined surface). The laser irradiated structures were initially characterized by Scanning Electronic Microscopy (SEM) and x ray diffraction (DRX) the HA group was subjected apatites treatment following the characterization by DRX, contact angle measurements and Infra red spectroscopy. The biological evaluations were performed by primary culture and differentiation of human stem cell. The parameters of in vitro evaluations were: Cell adhesion and proliferation by DNA quantification, cell metabolism, and cell morphology by SEM and fluorescence microscopy. The osteogenic differentiation was determined by ALP/Osteocalcin levels associated with SEM-EDS comparison. Results: All the experimental groups show less cell adhesion and proliferation at the initial stage of experiments than control group between 1 - 7 days. After 7 days the proliferation and cell metabolism increase on all experimental groups. The SEM micrographies associated with ALP/osteocalcin levels showed significant osteogenic differentiation on L1 group with significance differences of ALP/protein levels at day 7 (P<0.05), in addition, the HA group shows high levels ALP/Protein at 21 days. Conclusion: The laser beam irradiation process presented is clean, rapid and easy way to obtain a layer of oxides with micro and nanostructures. The best performance was found for L1 group with significant levels of osteocalcin and associated with morphological comparison, all experimental groups... (Complete abstract click electronic access below) / Orientador: Antonio Carlos Guastaldi / Coorientador: Helena Maria Pires Gaspar Tomas / Banca: Rogério Margonar / Banca: Roberto Henrique Barbeiro / Banca: Francisco Jose Correa Braga / Banca: Paulo Tambasco de Oliveira / Doutor
269

Avaliação da atividade fotocatalítica de filmes multicamadas SnO2 / Ag / TiO2 /

Kisen, Carla Yuri. January 2017 (has links)
Orientador: Leinig Antonio Perazolli / Banca: Elias de Souza Monteiro Filho / Banca: Elaine Cristina Paris / Resumo: Neste trabalho foi realizado um estudo das propriedades fotocatalíticas de filmes multicamadas SnO2/Ag/TiO2 e SnO2/Ag/TiO2 dopado com Ag. A camada de TiO2 (sem e com dopagem de Ag) foi obtida pelo método Pechini. Os catalisadores foram preparados com diferentes percentagens de prata (0,0, 0,5 e 1,0%) e diferentes temperaturas de calcinação (500, 600 e 700°C). Foram caracterizados por microscopia eletrônica de varredura (FEG - SEM) com espectroscopia de dispersão de energia (EDS), difração de Raios X (DRX), espectroscopia de reflexão difusa (ERD), microscopia eletrônica de transmissão de alta resolução (HRTEM), área de superfície específica baseado no método BET, espectroscopia de fotoluminescência (PL) e espectroscopia de fotoelétrons de Raios X (XPS). A atividade fotocatalítica dos pós foi determinada por testes de descoloração do corante Rodamina-B. A solução contendo o corante e o catalisador, na concentração de 0,01 mmol L-1 e 0,1 g L-1, respectivamente, foi submetida a radiação com lâmpada germicida de 11 W por 120 minutos. Os testes de controle, para efeito de comparação, foram realizados com TiO2 anatase (marca Synth) e testes de fotólise. Nas imagens, obtidas por MEV, todas as composições de prata empregadas apresentaram morfologias semelhantes, a elevação da temperatura de calcinação leva a uma diminuição da porosidade e a geração de agregados de partículas (coalescência). Os difratogramas de Raios X indicam a influência da prata na geração de fases distintas de T... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work, a study of photocatalytic properties of multi-layer films consisting of SnO2/Ag/TiO2 and SnO2/Ag/TiO2 doped with silver. The TiO2 layer (without and with Ag doping) was obtained by the Pechini method. The catalysts were prepared with different percentage of silver (0, 0,5 and 1,0 %) and different calcination temperatures (500, 600 and 700°C), characterized by field emission gun - scanning electron microscopy (FEG-SEM) with spectroscopy energy dispersive (EDS), X-ray diffraction (XRD), diffuse reflectance spectroscopy (ERD), high resolution transmission electron microscopy (HRTEM), specific surface area based on the BET method, Photoluminescence spectroscopy (PL) and X-ray photoelectron spectroscopy (XPS).The powders' photocatalytic activity was defined by Rhodamine-B discoloration test. The solution containing the dye and the catalyst, in the concentration of 0,01 mmol L-1 e 0,1 g L-1 respectively, were submitted to radiation with 11 W germicidal lamp for 120 minutes. The control tests, for comparison effects, were made with TiO2 anatase (Synth brand) and photolysis tests. In the images, obtained by SEM, all the silver compositions employed presented similar morphologies, the calcination temperature rise leads to a decreased porosity and the generation of particles clusters. The X-ray diffractograms indicates the doping influence in the generation of distinct TiO2 phases during the catalysts synthesis, stabilizing the anatase phase. The BET, HRTEM, ERD analysis... (Complete abstract click electronic access below) / Mestre
270

Âncora de titânio na sutura iliofemoral para tratamento de luxação coxofemoral traumática em cães : descrição da técnica e estudo de 12 casos /

Rocha, Artur Gouveia. January 2017 (has links)
Orientador: João Guilherme Padilha Filho / Banca: Gustavo Garkalns de Souza Oliveira / Banca: Elói dos Santos Portugal / Banca: Paola Castro Moraes / Banca: Márcia Rita Fernandes Machado / Resumo: As técnicas cirúrgicas extra-articulares para estabilização do qua-dril luxado têm sido mais estudadas, tendo em vista a manutenção da integridade da cartilagem articular e a redução da progressão da doença articular degenerativa. Den-tre estas técnicas, a sutura de fixação iliofemoral, tem se mostrado efetiva, com boa recuperação dos pacientes. O propósito deste trabalho foi avaliar a âncora de titânio como método de fixação do fio se sutura ao ílio, substituindo, assim, na técnica de fixação iliofemoral, a trabalhosa manobra de passagem do material de sutura através de um túnel no corpo ilíaco. Esta técnica foi realizada em 12 cães, de raças variadas, atendidos no Hospital Veterinário da UNESP - Jaboticabal. Os pacientes, em sua to-talidade, vítimas de atropelamento, se apresentaram com diferentes graus de claudi-cação e dor no quadril. Em alguns casos, ocorreram reluxações após tentativas de redução fechada e esses pacientes foram submetidos redução e fixação cirúrgica da luxação por meio da sutura iliofemoral modificada. Os pacientes foram acompanhados clínica e radiograficamente por períodos variados entre 30 a 90 dias de pós-operatório. Observou-se apoio com carga no membro em média de três dias após os procedi-mentos e aos 10 dias a maioria dos pacientes não claudicava. Não foram visibilizadas, no exame radiográfico osteólise perimplante. A sutura ílio femoral, modificada pela utilização de uma âncora fixada ao ílio, mostrou-se eficiente no tratamento da luxação coxofe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Extra-articular surgical techniques for stabilization of dislocated hip have been most studied, with a view to maintaining the integrity of articular cartilage and reducing the progression of degenerative joint disease. Among these techniques, the suture fixation iliofemoral, has proven effective, with good recovery of patients. The purpose of this study was to evaluate the anchor titanium as the wire clamping method suture the ileum, thus replacing, in the iliofemoral fixation technique, the laborious ma-neuvering passage of suture material through a tunnel in iliac body. This technique was performed in 10 dogs of various races attended at UNESP Veterinary Hospital - Jaboticabal. The patients, in its entirety, victims of trampling presented with varying degrees of lameness and pain in the hip. In some cases, attempts occurred after reluxações closed reduction and forami these patients undergoing surgical fixation and reduction of the dislocation by modified iliofemoral suture. The patients were followed clinically and radiographically for varying periods between 30 to 90 days postopera-tively. He observed the load support member on average 3 days after the procedure and 10 days most patients do not limping. There were visualized on radiographic ex-amination, perimplante osteolysis, or the appearance of osteophytes or joint sclerosis. The ilium femoral suture, modified by the use of an anchor attached to the ilium, was efficient in the treatment of hip dislocation, not being observed dislocation recurrence. Additionally, the use of titanium anchor greatly facilitating the fixing of the wire ilium, significantly reducing surgical time. / Doutor

Page generated in 0.0531 seconds