• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 16
  • 4
  • Tagged with
  • 65
  • 65
  • 24
  • 23
  • 22
  • 22
  • 21
  • 19
  • 15
  • 12
  • 11
  • 11
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Identification des descripteurs macroscopiques de la dérive pour sa modélisation / Identification of macroscop descriptors of drift for spray drift modeling

Alheidary, Majid 07 March 2016 (has links)
La dérive de pulvérisation peut être mesurée au champ ou en soufflerie. Paradoxalement, les tests au champ sont sujets à de grandes variations dues aux conditions atmosphériques mais peuvent être plus facilement réalisés contrairement aux tests en soufflerie. Ainsi les principaux modèles de dérive sont basés sur des mesures au champ alors que peu de modèles s’inspirent de mesures en soufflerie. L’objectif de ce travail a été de définir un ou des descripteurs de la dérive sur la base de l’analyse de courbes de dépôts obtenues dans la soufflerie d’IRSTEA Montpellier. Par rapport aux souffleries existantes, un protocole d’exposition de longue durée a été utilisé avec une forte densité d’échantillonnage. Un plan expérimental comprenant 99 modalités a été réalisé en tenant compte de différents types de buses (FF, AI, AI Twin jet), différente hauteurs de rampe de 40 à 80cm, différentes positions de la rampe (frontale, latérale et angles intermédiaires) et différentes vitesses de vent entre 2 et 7.5m s-1. Les résultats ont montré que le taux de dérive à 5m sous le vent (DR5) correspond au descripteur le plus robuste si l’on tient compte du large spectre de paramètres et de réglages. Des modèles de premier ordre ont été définis pour l’expression de l’effet de la vitesse du vent ainsi que de la hauteur de rampe selon le temps de vol des gouttes (ToF). Ainsi il est possible de comparer des résultats issus de conditions expérimentales différentes et de simuler l’effet de la vitesse du vent et la hauteur de la rampe pour un type donné de buse. Des mesures in situ de taille de gouttes ont confirmé la pertinence du temps de vol comme base de l’expression des résultats. / Spray drift might be measured either infield or in a wind tunnel through specific sampling strategies. Paradoxically field tests are subjected to a high variability due to the atmospheric conditions but can be more easily conducted in the absence of a wind tunnel. The result is that most of spray drift models are based on infield measurements. Conversely very few models were developed on the basis of wind tunnel measurements. The objective of this work was to define spray drift descriptors from the analysis of drift curves in IRSTEA wind tunnel. Compared to the majority of existing wind tunnels, a long duration exposure protocol was applied with a high sampling density. A large experimental plan of 99 modalities were conducted including nozzle types (FF, AI, AI Twin jet), boom heights from 40 to 80cm, boom positions (frontal, lateral, and intermediate angles) and wind velocities from 2 to 7.5ms-1. Results showed that the drift ratio at 5m (DR5) was the most robust drift indicator considering the wide range of parameters and operations conditions (wind velocity, boom height). First order models were drawn for the expression of the effect of the wind velocity and the boom height according to the droplet time of flight (ToF). As a result it was possible to compare data from different experimental conditions and to simulate the effect of the wind velocity and the boom height for a given type of nozzle. In situ droplet size measurements confirmed the relevance of the time of flight expression.
22

Etude de l’influence de différents modes de synthèse sur la nature de la phase active de catalyseurs à base de molybdène : Caractérisation par couplage de spectroscopies XPS/LEIS/ToF-SIMS / Study of the influence of the different preparation methods on the active phase nature of Mo-based catalysts : Combined XPS/LEIS/ToF-SIMS spectroscopies characterization

Herbin, Morgane 25 September 2014 (has links)
Le couplage de techniques d’analyse de surface (XPS, LEIS et ToF-SIMS) a permis de caractériser la nature de la phase active sur des catalyseurs à base de Mo en fonction de différents modes de synthèse. Afin d’imiter le mode par voie chimique par imprégnation, des catalyseurs modèles ont été préparés par spin coating. En outre, une nouvelle voie physique, par pulvérisation magnétron, a été explorée pour la synthèse de catalyseurs. Des corrélations entre les données spectroscopiques XPS et LEIS sur les systèmes modèles permettent de déterminer le taux de recouvrement et l’épaisseur des espèces MoOx déposées. L’étude ToF-SIMS permet de confirmer la structure de la phase active : des entités monomériques à faible teneur et polymériques à plus haute teneur en Mo. Enfin, les performances catalytiques des différents systèmes pour l’oxydation ménagée du méthanol sont discutées au regard des caractérisations spectroscopiques. Ce travail a été réalisé dans le cadre du projet CATARR INTERREG IV (Materia Nova, Université de Mons et Université Lille1). / The coupling of surface analysis techniques (XPS, LEIS et ToF-SIMS) allowed to characterize the nature of the active phase on Mo-based catalysts according to different modes of synthesis. To imitate chemical means by impregnation mode, model catalysts we prepared by spin-coating. In addition, a new physical path, by magnetron sputtering, has been explored for the synthesis of catalysts. Correlations between spectroscopic data XPS and LEIS on model systems determine the recovery rate and the structure of the active phase : Mo low content monomeric and high content polymeric entities. Finally, the catalytic performances of the different catalytic systems for the controlled oxidation of methanol are discussed under spectroscopic characterizations. This work has been performed within INTERREG IV CATARR network (Materia Nova, Mons University and Lille1 University).
23

Spectres en énergie des neutrons prompts de fission : optimisation du dispositif expérimental et application à l'²³⁸U / Prompt fission neutron energy spectra : optimisation of the experimental setup and application to ²³⁸U

Sardet, Alix 02 October 2015 (has links)
La fission nucléaire est un phénomène complexe dont tous les mécanismes ne sont pas entièrement compris. Dans le cadre d'une coopération internationale, le CEA/DAM/DIF étudie les spectres en énergie des neutrons prompts émis lors de la fission induite par des neutrons rapides, et plus particulièrement la zone à basse énergie de ces spectres (<1 MeV). Ce travail de thèse a consisté à optimiser un dispositif expérimental de mesure de neutrons prompts de fission. Dans un premier temps, de nouveaux détecteurs de fission ont été développés. Nous en rapportons ici la conception et étudions leurs performances en termes de discrimination alpha-fission, de résolution en temps et de distorsion sur le spectre mesuré. Le second axe de développement abordé au cours de cette thèse est celui de la détection des neutrons. Plusieurs types de détecteurs ont été comparés (discrimination neutron-gamma, efficacité de détection), en vue d'optimiser la détection des neutrons de basse énergie (<1 MeV). Ce mémoire présente les résultats de ces études. Enfin, le dispositif expérimental ainsi optimisé est utilisé pour mesurer le spectre en énergie des neutrons prompts émis lors de la fission induite par neutrons de l' ²³⁸UU. Après avoir présenté la méthode utilisée pour l'analyse des données, les résultats obtenus sont interprétés en termes de modèles et d'évaluations. / The nuclear fission is a complex phenomenon whose mechanisms are not fully understood. Within the framework of an international cooperation, the CEA/DAM/DIF is taking part in the study of prompt fission neutron energy spectra from fast neutron induced fission, focusing on the low energy domain of these spectra (<1 MeV). This PhD was dedicated to the optimization of the experimental setup. New fission detectors were developed. We report on their conception and their performances in terms of alpha-fission discrimination, timing resolution and distortion on the measured spectrum. In a second step, several neutron detectors were studied (neutron-gamma discrimination, detection efficiency), so as to optimize the detection of low energy neutrons (<1 MeV). In the present document, we report on the results of this comparative study. Finally, the optimized experimental setup was used to measure prompt fission neutron energy spectra for the fast-neutron induced fission of ²³⁸U. After detailing the data analysis method, the results are interpreted in terms of models and evaluations.
24

Mesure de la section efficace de production de paires de photons isolés dans l'expérience ATLAS au LHC et étude des couplages à quatre photons / Measurement of the isolated di-photon cross section with the ATLAS detector at the LHC and study of four photon couplings

Saimpert, Matthias 27 June 2016 (has links)
Le LHC, qui est le collisionneur proton-proton le plus puissant du monde situé au CERN (Suisse), donne une occasion unique de pouvoir tester nos connaissances des interactions fondamentales à l'échelle du TeV. Au cours de cette thèse, deux projets ont été accomplis dans ce but. Tout d'abord, la mesure de la section efficace de production d'au moins deux photons dans l'état final (pp→γγ+X) a été réalisée à l'aide des données prises avec une énergie dans le centre de masse de 8 TeV par le détecteur ATLAS, qui est l'un des détecteurs polyvalents installé autour du LHC. Les photons sont des particules intéressantes pour tester la théorie de l'interaction forte (chromodynamique quantique ou QCD) car ils sont couplés aux quarks et aux gluons sans pour autant s'hadroniser, ce qui permet de pouvoir les mesurer avec une très bonne résolution. La mesure de leur taux de production au LHC permet de tester la QCD à la fois dans le domaine perturbatif et non-perturbatif. Elle est également sensible à l'émission de particules à basse énergie dans l'état initial, qui est un phénomène délicat à décrire d'un point de vue théorique à cause des divergences molles et collinéaires découlant de la QCD. Les incertitudes expérimentales ont été divisées par un facteur 2 ou plus comparé aux mesures réalisées précédemment au LHC ou au Tevatron (Fermilab, États-Unis) et la très bonne statistique des données d'ATLAS à 8 TeV a permis une augmentation significative à la fois de la résolution et de la portée de la mesure. En général, un bon accord est observé avec les prédictions théoriques. Le second projet réalisé au cours de la thèse est consacré à l'évaluation du potentiel de découverte relié à la mesure de la diffusion γγ au LHC (γγ→γγ). La diffusion γγ est un processus singulier car prédit uniquement via des fluctuations quantiques qui n'a jamais été observé directement. Il implique un terme de couplage à quatre photons, qui montre une sensibilité significative à une large gamme de modèles d'extension du modèle standard à haute énergie, tels que ceux prédisant l'existence de dimensions supplémentaires de l'espace pour résoudre le problème de hiérarchie. En tirant profit du flux important de photons venant des protons au LHC, je montre qu'il est possible de découvrir des couplages anomaux à quatre photons avec une sensibilité permettant de rivaliser avec certaines recherches directes. Enfin, j'ai eu l'occasion de tester la nouvelle puce SAMPIC qui vise à réaliser des mesures de temps de vol avec une précision de l'ordre de quelques picosecondes grâce à un échantillonnage rapide des signaux de détecteur. Les performances de SAMPIC ont été testées à partir de signaux gaussiens produits par un générateur et par des détecteurs soumis à des impulsions infrarouges. Dans ces conditions idéales, SAMPIC permet de réaliser des mesures de temps de vol avec une résolution de l'ordre de 4 (40) ps pour les signaux générés (de détecteurs). / The LHC, which is the most powerful proton-proton collider in the world located at CERN (Switzerland), brings unprecedented opportunities to test our knowledge of the fundamental interactions at the TeV scale. In this work, two main projects have been achieved for this purpose. First, the production cross section measurement of at least two photons in the final state (pp→γγ+X) is performed with data taken at a center-of-mass energy of 8 TeV by the ATLAS detector, which is one of the multipurpose detector installed around the LHC ring. Photons are interesting probes to test the theory of strong interactions (Quantum chromodynamics or QCD) since they couple significantly to quarks and gluons but do not hadronize and thus still allow to perform high resolution measurements. The measurement of their production rate at the LHC allows to test QCD in both the perturbative and the non-perturbative domain. It is also sensitive to the emission of soft particles in the initial-state, which is tricky to handle on the theory side due to the collinear and soft divergences arising in QCD. Experimental uncertainties have been reduced by a factor 2 or more with respect to the measurements performed previously at the LHC or at the Tevatron (Fermilab, USA) and the high statistics of the ATLAS data sample at 8 TeV allows to increase significantly both the reach and the resolution of the measurement. In general, a good agreement is observed with theoretical predictions. The second project achieved in this work is dedicated to the evaluation of the light-by-light scattering potential (LbyL, γγ→γγ) for new physics searches. LbyL is an intriguing process arising from quantum fluctuations only that has never been observed directly. It involves four-photon couplings, which are shown to be highly sensitive to a broad range of new physics models at high energy such as the ones predicting the existence of extra spatial dimensions to solve the hierarchy problem currently affecting the standard model of particle physics. By taking benefit of the photon flux from the protons at the LHC, I show that one may discover anomalous four photon couplings with a sensitivity allowing to compete with several direct new physics searches. Finally, I had the opportunity to test the new SAMPIC chip which aims to perform time-of-flight measurements with a few picoseconds precision from fast samplings of detector signals. SAMPIC timing capabilities have been tested using Gaussian signals generated by a signal generator or by silicon detectors pulsed with an infrared laser. Under these ideal conditions, the SAMPIC chip has proven to be capable of timing resolutions down to 4 (40) ps with synthesized (silicon detector) signals.
25

Development of a detector for the simultaneous measurement and for the study of uranium-233 capture and fission yields at the CERN n_TOF neutron source / Développement d'un détecteur pour la mesure simultanée et l’étude des rendements de capture et de fission de l’uranium-233 auprès de la source de neutrons n_TOF au CERN

Bacak, Michael 25 October 2019 (has links)
Des perspectives énergétiques sobres en carbone pour atténuer le changement climatique nécessitent le remplacement des combustibles fossiles par des sources produisant peu de CO2, par exemple l’énergie nucléaire. L'une des options discutées par le Forum international Gen-IV pour la prochaine génération de réacteurs nucléaires consiste à utiliser le cycle du thorium. L'isotope fissile 233U est l'un des isotopes les plus importants du cycle du thorium et est directement responsable du bilan neutronique. L'une des particularités de ce noyau est d'avoir une section efficace de capture qui est inférieure d'un ordre de grandeur à celle de fission. Cette circonstance rend très difficile la mesure de sa section efficace de capture, comme l'atteste seulement deux jeux de données à haute résolution disponibles depuis les années 1960. Dans cette thèse, une nouvelle mesure auprès de la source de neutrons n_TOF est décrite utilisant une nouvelle chambre à fission compacte insérée au centre d'un détecteur de rayons gamma, le calorimètre à absorption totale. La chambre à fission permet d’identifier et de soustraire les rayons gamma de la réaction de fission dans le but d’améliorer la précision de la section efficace de capture de 233U. La chambre à fission est conçue dans cet objectif. Son excellente performance est décrite en détail et permet d'extraire des informations sur les rayons gamma de fission. Une discussion détaillée du processus de réduction des données et des éléments clés de l’analyse, est présentée et aboutit au calcul du rapport alpha de 233U, le rapport entre la section efficace de capture et celle de fission. / A low-carbon energy outlook to mitigate the climate change requires the replacement of fossil fuel by sources with low CO2 emissions, like nuclear energy.. One of the options discussed in the Gen-IV International Forum for the the next generation of nuclear reactors is to use the thorium cycle. The fissile isotope 233U is among the most important isotopes in the thorium cycle and directly responsible for the neutron economy. One of the particularities of this nucleus is to have a capture cross section which is one order of magnitude lower than fission, making the measurement of the 233U capture cross section very challenging as indicated by only two high resolution data sets available since the 1960s. In this thesis, a new measurement at the n_TOF neutron source is described employing a novel compact fission chamber inserted in the center of the Total Absorption Calorimeter g-ray detector. The fission chamber allows to tag and subsequently subtract the gamma rays from the fission reaction aiming to improve the accuracy of the 233U capture cross section.The performance of the custom tailored fission chamber is described in detail and allows to extract information about the prompt fission g-rays. A detailed discussion of the data reduction process and the key elements in the analysis is given resulting in the calculation of the 233U-alpha-ratio, the ratio between the capture and fission cross-section.
26

Conception d'un circuit d'étouffement de photodiodes avalanches monophotoniques pour une intégration matricielle dans un module de comptage monophotonique

Nolet, Frédéric January 2016 (has links)
De nombreuses applications en sciences nucléaires bénéficieraient d’un détecteur possédant une précision temporelle de 10 ps largeur à mi-hauteur à la mesure d’un photon unique. Par exemple, le projet de Time-Imaging Calorimeter en cours de conception au CERN requiert un détecteur possédant une telle précision temporelle afin de mesurer le temps de vol (TDV) et la trajectoire des particules émises lors des collisions dans les expériences du Large Hadron Collider (LHC), ce qui permet d’identifier ces dites particules. De plus, un détecteur possédant une précision temporelle de l’ordre de 10 ps permettra la mitigation de l’empilement des événements. Un second exemple est la tomographie d’émission par positrons (TEP), une modalité d’imagerie médicale non-invasive qui mesure la distribution d’un traceur radioactif afin d’étudier et détecter le cancer. Dans le but de développer un scanner TEP temps réel, le groupe de recherche en appareillage médical de Sherbrooke (GRAMS) travaille sur l’intégration de la mesure du TDV de l’interaction TEP. Les meilleures performances actuelles des détecteurs TEP se situent aux alentours de 150 ps, ce qui n’est pas suffisant pour intégrer le TDV dans un scanner TEP préclinique. Cette mesure exige une résolution temporelle TEP de l’ordre de 10 ps. La solution proposée par le GRAMS est de développer un module de comptage monophotonique (MCMP) 3D qui est composé d’une matrice de photodiodes avalanches monophotoniques (PAMP) reliée par des interconnexions verticales (TSV) à une matrice de circuits de lecture composée d’un circuit d’étouffement et d’un convertisseur temps-numérique. Ce détecteur permet donc de mesurer précisément le temps d’arrivée de chaque photon détecté. Ce document présente la conception du circuit d’étouffement réalisé en technologie CMOS 65 nm de TSMC (Taiwan Semiconductor Manufacturing Company) intégré à chaque pixel de 50 × 50 µm2 dans un MCMP 3D. Afin de répondre au besoin de précision temporelle de 10 ps dans un détecteur 3D, le circuit proposé est un circuit d’étouffement passif avec une recharge active possédant un amplificateur opérationnel en boucle ouverte à titre de comparateur de tension. L’amplificateur opérationnel utilisé possède un seuil ajustable de 0 à 2,5 V afin d’être en mesure d’évaluer le seuil optimal pour la mesure de gigue temporelle avec une PAMP. La taille finale du circuit d’étouffement est de 18 × 30 µm2 incluant l’amplificateur qui est d’une taille de 13 × 8 µm2, ce qui représente respectivement environ 22% et 4% de la taille totale du pixel. Le circuit d’étouffement possède une gigue temporelle de 4 ps largeur à mi-hauteur (LMH). Les résultats obtenus prouvent qu’il est possible d’intégrer de l’électronique de lecture de PAMP dans un MCMP 3D possédant des performances temporelles sous les 10 ps.
27

Conception, caractérisation et optimisation de SPAD en technologie Dalsa HV CMOS 0.8 μm pour intégration dans un 3D-SiPM

Parent, Samuel January 2016 (has links)
Résumé : Les photodiodes à avalanche monophotonique (SPAD) sont d'intérêts pour les applications requérant la détection de photons uniques avec une grande résolution temporelle, comme en physique des hautes énergies et en imagerie médicale. En fait, les matrices de SPAD, souvent appelés photomultiplicateurs sur silicium (SiPM), remplacent graduellement les tubes photomultiplicateurs (PMT) et les photodiodes à avalanche (APD). De plus, il y a une tendance à utiliser les matrices de SPAD en technologie CMOS afin d'obtenir des pixels intelligents optimisés pour la résolution temporelle. La fabrication de SPAD en technologie CMOS commerciale apporte plusieurs avantages par rapport aux procédés optoélectroniques comme le faible coût, la capacité de production, l'intégration d'électronique et la miniaturisation des systèmes. Cependant, le défaut principal du CMOS est le manque de flexibilité de conception au niveau de l'architecture du SPAD, causé par le caractère fixe et standardisé des étapes de fabrication en technologie CMOS. Un autre inconvénient des matrices de SPAD CMOS est la perte de surface photosensible amenée par la présence de circuits CMOS. Ce document présente la conception, la caractérisation et l'optimisation de SPAD fabriqués dans une technologie CMOS commerciale (Teledyne DALSA 0.8µm HV CMOS - TDSI CMOSP8G). Des modifications de procédé sur mesure ont été introduites en collaboration avec l'entreprise CMOS pour optimiser les SPAD tout en gardant la compatibilité CMOS. Les matrices de SPAD produites sont dédiées à être intégrées en 3D avec de l'électronique CMOS économique (TDSI) ou avec de l'électronique CMOS submicronique avancée, produisant ainsi un SiPM 3D numérique. Ce SiPM 3D innovateur vise à remplacer les PMT, les APD et les SiPM commerciaux dans les applications à haute résolution temporelle. L'objectif principal du groupe de recherche est de développer un SiPM 3D avec une résolution temporelle de 10 ps pour usage en physique des hautes énergies et en imagerie médicale. Ces applications demandent des procédés fiables avec une capacité de production certifiée, ce qui justifie la volonté de produire le SiPM 3D avec des technologies CMOS commerciales. Ce mémoire étudie la conception, la caractérisation et l'optimisation de SPAD fabriqués en technologie TDSI-CMOSP8G. / Abstract : Single Photon Avalanche Diodes (SPAD) generate much interest in applications which require single photon detection and excellent timing resolution, such as high energy physics and medical imaging. In fact, SPAD arrays such as Silicon PhotoMultipliers (SiPM) are gradually replacing PhotoMultiplier Tubes (PMT) and Avalanche PhotoDiodes (APD). There is now a trend moving towards SPAD arrays in CMOS technologies with smart pixels control for high timing demanding applications. Making SPAD in commercial CMOS technologies provides several advantages over optoelectronic processes such as lower costs, higher production capabilities, easier electronics integration and system miniaturization. However, the major drawback is the lack of flexibility when designing the SPAD architecture because all fabrication steps are fixed by the CMOS technology used. Another drawback of CMOS SPAD arrays is the loss of photosensitive areas caused by the CMOS circuits integration. This document presents SPAD design, characterization and optimization made in a commercial CMOS technology (Teledyne DALSA 0.8 µm HV CMOS - TDSI CMOSP8G). Custom process variations have been performed in partnership with the CMOS foundry to optimize the SPAD while keeping the CMOS line compatibility. The realized SPAD and SPAD arrays are dedicated to 3D integration with either low-cost TDSI CMOS electronics or advanced deep sub-micron CMOS electronics to perform a 3D digital SiPM (3D-SiPM). The novel 3D-SiPM is intended to replace PMT, APD and commercially available SiPM in timing demanding applications. The group main objective is to develop a 10 ps timing resolution 3D-SiPM for use in high energy physics and medical imaging applications. Those applications require reliable technologies with a certified production capability, which justifies the actual effort to use commercial CMOS line to develop our 3D-SiPM. This dissertation focuses on SPAD design, characterization and optimization made in the TDSI-CMOSP8G technology.
28

Étude de l'interaction entre ions multichargés et systèmes complexes d'intérêt biologique : effets de l'environnement à l'échelle moléculaire

Capron, Michael 05 December 2011 (has links) (PDF)
Cette thèse présente l'étude de l'interaction d'ions multichargés de basse énergie (quelques 10 keV) avec des systèmes complexes d'intérêt biologique (acides aminés et base azotée). Dans ce cadre, l'objectif de travail se situe dans la compréhension et la mise en évidence d'effets de l'environnement moléculaire. Afin d'étudier ce phénomène, les spectres en temps de vol des produits cationiques issus de la collision ont été comparés dans le cas de molécules isolées ou au sein d'agrégats purs ou mixtes. Il est apparu que l'environnement moléculaire permettait d'une part de protéger la molécule en autorisant la répartition de l'énergie et de la charge après la collision (se traduisant par une diminution de la fragmentation globale, la fermeture de certaines voies, ...). D'autre part, l'environnement semble susceptible de fragiliser certaines liaisons intramoléculaires comme l'illustre l'apparition de nouvelles voies de fragmentions dans les agrégats d'adénine. Enfin, l'agrégat constitue également un premier environnement chimique avec lequel la molécule va pouvoir interagir. Les spectres obtenus avec des agrégats hydratés d'adénine signent par exemple le transfert d'un proton depuis les molécules d'eau vers la base azotée. Plus surprenant encore, les ions multichargés semblent induire la formation de liaisons peptidiques au sein d'agrégats de beta-alanine. Ce dernier résultat a été étudié plus en détails en fonction de la taille des agrégats ou de l'ion projectile utilisé. Un certains nombre de critères (flexibilité et géométrie de la molécule, testées en utilisant d'autres acides aminés) ont été avancés pour prédire la formation de liaisons peptidiques.
29

Segmentation et extraction de caractéristiques des vaisseaux sanguins cérébraux à l'aide de l'IRM / Segmenting and characteristic extraction of cerebral blood vessels in MRI

Bizeau, Alexandre January 2017 (has links)
Le couplage neuro-vasculaire est un domaine grandissant. Ce dernier étudie les effets de l’activité cérébrale sur le comportement du flux sanguin cérébral (cerebral blood flow, CBF) et sur le flux des vaisseaux sanguins. Avec l’aide de l’imagerie par résonance magnétique (IRM), il est possible d’obtenir des images comme les images pondérées par susceptibilité (susceptibility weighted imaging, SWI) pour voir les veines ou bien avec des images de temps de vol par angiographie (time-of-flight magnetic resonance angiography, TOF MRA) pour imager les artères. Ces images permettent d’avoir une représentation structurelle des vaisseaux dans le cerveau. Ce mémoire présente une méthode permettant la segmentation des vaisseaux sanguins à partir d’images structurelles afin d’en extraire les caractéristiques. En utilisant le masque de segmentation, il est possible de calculer le diamètre des vaisseaux ainsi que leur longueur. Avec l’aide de tels outils de segmentation automatique, nous avons conduit une étude permettant d’analyser le comportement des vaisseaux sanguins lors d’activités neuronales. Grâce à une stimulation visuelle, nous avons fait l’acquisition de deux images; la première dite au repos et la seconde avec stimulation. Nous avons pu comparer le diamètre dans chacune des images et ainsi obtenir la vasodilatation en millimètre, mais également en pourcentage, et cela pour chaque voxel. Nous avons également calculé la distance entre le site d’activation et un voxel pour observer l’amplitude de la vasodilatation en fonction de la distance. Tout ceci permet d’avoir une meilleure compréhension du système vasculaire du cerveau humain. / Abstract : The neurovascular coupling is a growing field; it studies the effects of cerebral activity on the behaviour of cerebral blood flow (CBF) and the blood vessels themselves. With the help of magnetic resonance imaging (MRI), it is possible to obtain images such as susceptibility weighted imaging (SWI) to see the veins or time-of-flight magnetic resonance angiography (TOF MRA) to visualize the arteries. These images allow having a structural representation of vessels in the brain. This thesis presents a method to segment blood vessels from structural images and extract their features. Using the segmentation mask, it is possible to calculate the diameter of the vessels as well as their length. With the help of such automatic segmentation tools, we conducted a study to analyze the behaviour of blood vessels during neuronal activities. Due to visual stimulation, we have acquired two images; one at rest and the other with stimulation. We compare the diameter in each of the images and obtain vasodilation in millimeters, but also as a percentage in each voxel. We also calculated the distance between the activation site and each voxel to see the magnitude of the vasodilation function of the distance. All this provides a better understanding of the vascular system of the human brain.
30

Élaboration et caractérisation de matériaux hybrides "nanoparticules Zn0 - cristaux liquides" pour applications aux cellules photovoltaïques / Elaboration and characterization of hybrid materials "nanoparticles ZnO - Liquid crystals" for photovoltaic cells applications

Halaby Macary, Mikhael 09 January 2019 (has links)
Ce travail de thèse s'inscrit dans l'essor important que connaît actuellement le domaine des énergies renouvelables en terme de recherche et de nouvelles technologies de l'énergie. Il est consacré à l'étude de nouveaux matériaux hybrides "nanoparticules ZnO - cristaux liquides" en vue d'applications aux cellules solaires de type hétérojonctions en volume. La motivation est d'utiliser les propriétés d'auto-organisation et de transport de charges des cristaux liquides et d'augmenter les interfaces donneur-accepteur afin d'améliorer leurs performances. Pour la mesures des mobilités des porteurs de charge, un banc de mesure "temps de vol" entièrement automatisé a été développé. Deux cristaux liquides calamitiques ont été caractérisés (DSC, microscopie optique polarisée, UV et "temps de vol"). Deux types de transports de charge, l'un ionique, l'autre électronique sont mis en évidence pour des charges positives et négatives avec des mobilités indépendantes du champ électrique et des comportements différents en fonction de la température. Un procédé d'élaboration des matériaux hybrides a été mis au point. Les caractérisations de ces matériaux montrent l'influence de la concentration en nanoparticules (0,05 à 38% en volume). La taille des domaines dans les phases cristal liquide augmente avec la concentration alors que la température de transition isotrope-SmA diminue fortement. Un résultat important est que les phénomènes de transport sont conservés pour des concentrations importantes (jusque 12% en volume). Le transport électronique est même amélioré. Les propriétés des matériaux élaborés apparaissent intéressantes pour des applications aux cellules photovoltaïques. / This thesis work is a part of the significant growth that is currently taking place in the field of the renewable energy in terms of research and new energy technologies. It is dedicated to the study of new hybrid material "zno particles - liquid crystals" for the applications in "bulk heterojunction" solar cells. The motivation is to increase the donor-acceptor interfaces in hybrid material and to combine the self-organizing and charge transport properties of liquid crystals, in order to improve their performance. A completely automated "time of flight" measuring set-up is developed, for the measurement of the charge carriers mobility in the aforementioned hybrid material. Using the dsc, polarized optical microscopy, uv-visible spectroscopy and "time of flight", we have characterized two calamitic liquid crystals. Two types of charge transport, one ionic, and the other electronic, are highlighted for positive and negative charges with electric field independent mobility and different behaviors with temperature. A process for the elaboration of hybrid materials is developed. The characterization of these materials show the influence of nanoparticles concentrations (0,05 to 38% by volume). The size of the domains in the liquid crystal phases increases with the concentration whereas the isotropic-sma phase transition temperature decreases monotically. Under controlled dispersion of zno nanoparticles in host liquid crystal up to 12% by volume, we have conserved the transport phenomena in hybrid material and study has shown that electronic transport is improved. The characterized hybrid materials have shown their potential application in organic photovoltaic.

Page generated in 0.0312 seconds