Spelling suggestions: "subject:"tensile"" "subject:"ensile""
371 |
Análise das imagens de ruptura de corpos de prova de polipropileno em ensaio de tração obtidas através de câmera de alta velocidade / High-speed camera analysis of rupture of polypropylene specimens in tensile testsBacchi, Renato Vieira 19 August 2018 (has links)
Orientadores: Edvaldo Sabadini, Marco-Aurelio De Paoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-19T06:55:08Z (GMT). No. of bitstreams: 1
Bacchi_RenatoVieira_M.pdf: 13069240 bytes, checksum: 33b4fb8f5e4184296681a0de7210799c (MD5)
Previous issue date: 2011 / Resumo: Peças de polipropileno isotático, iPP, moldadas por injeção podem apresentar variação de propriedades em função dos parâmetros de injeção. Uma dessas propriedades é a propagação de ruptura, que foi estudada neste trabalho com o uso de imagens obtidas com câmera de alta velocidade ajustada para velocidades de captura entre 18.000 e 45.000 fotos por segundo. Os parâmetros modificados no processo de moldagem por injeção foram o tempo de resfriamento e a temperatura do molde. Foram formados seis grupos de corpos de prova (CP) a serem submetidos aos ensaios de tração. As imagens dos rompimentos nos ensaios de tração foram capturadas com a câmera de alta velocidade. Os CP dos grupos 1, 2 e 3 foram resfriados em molde a 22 °C durante 8, 25 e 55 s, respectivamente. Os CP dos grupos 4, 5 e 6 foram resfriados em molde a 80 °C por 8, 25 e 55 s, respectivamente. Foram observados três padrões de rompimento associados aos diferentes grupos. O primeiro padrão correspondente aos CP dos grupos 1 e 4, com tempos de ruptura entre 0,04 e 0,09 ms. O segundo padrão, apresentado pelos grupos 2 e 3, apresenta formação de pescoço e alto alongamento, porém sem tempo de ruptura definido. O terceiro padrão, observado nos grupos 5 e 6, apresenta ruptura com tempo de propagação médio de 1,5 ms e propagação elipsóide da fissura. Foram realizadas medidas de difração de raios-X e calorimetria diferencial exploratória, mas não foram observadas variações significativas dos graus de cristalinidade para os diferentes grupos. Foram obtidas micrografias por microscopia eletrônica de varredura para amostras dos seis grupos, que mostraram maior uniformidade na superfície de ruptura para os grupos 1 e 4. Para os grupos 2 e 3 foi observada presença de fibrilas. Para os grupos 5 e 6 foram observadas diferenças significativas entre as superfícies do centro do e das extremidades do CP. Para observar os efeitos do envelhecimento nos padrões de ruptura, foram armazenados alguns CP de cada um dos grupos durante 12 semanas. O enrijecimento do material tende a causar ruptura mais rápida em todos os grupos e os grupos 2 e 3 foram os mais afetados. Os resultados deste trabalho mostram que, não apenas as propriedades mecânicas do iPP são afetadas pelas variáveis na moldagem por injeção como também os mecanismos de rompimento variam consideravelmente, e estes são claramente observados com imagens em alta velocidade / Abstract: Injection-molded isotactic polypropylene, iPP, samples present different properties variation as a function of the injection parameters. One of these properties is the rupture propagation on the material, which was studied with the use a high-speed camera adjusted to capture from 18,000 to 45,000 frames per second. The injection molding parameters modified were: cooling time and temperature of the mold. Six groups of specimens were molded and submitted to tensile tests until failure. The rupture images were capture with the high-speed camera. The specimens of the groups 1, 2 and 3 were cooled in the mold at 22 °C during 8, 25 and 55 seconds, respectively. Groups 4, 5 and 6 were cooled in the mold at 80 °C during 8, 25 and 55 s, respectively. Three major rupture patterns associated with the groups were observed. The first pattern, presented by groups 1 and 4, consists in a rapid rupture, with time of propagation between 0.04 and 0.09 ms. A second pattern, observed in groups 2 and 3, presents necking and high elongation, but without a precise time for complete rupture. The third pattern, observed for groups 5 and 6, shows an ellipsoid crack propagation, with an average time for rupture of 1.5 ms. X-Ray diffraction and differential scanning calorimetry measurements were made, but no considerable differences in the degree of crystallinity among the groups was observed. Scanning electron microscopy images of the rupture surface of the specimens showed that there is considerable uniformity in groups 1 and 4. In groups 2 and 3 the appearance of fibrils was observed, whilst for groups 5 and 6 considerable differences between the skin and the core of the specimen was observed. Physical ageing effects on the rupture patterns were studied after the storage of few specimens during 12 weeks. Hardening of the material, due to physical ageing, affected all the groups, but it was most apparent in groups 2 and 3, which started to behave more like the other groups after this time. The result in this work showed that not only the mechanical properties of iPP are affected by the modification in the mold injection parameters, but also the rupture mechanisms can considerably vary. This is observed clearly in the high-speed images / Mestrado / Físico-Química / Mestre em Química
|
372 |
Estudo do comportamento da resina base na formulação de compósitos de politetrafluoretileno com bronze / Study of the behavior of the base resin in the formulation of polytetrafluoroethylene composites with bronzeBento, Ronaldo Euzébio 19 August 2018 (has links)
Orientador: João Sinézio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-19T08:39:45Z (GMT). No. of bitstreams: 1
Bento_RonaldoEuzebio_M.pdf: 1080016 bytes, checksum: c783e50a51346a7d89eb82f52976eb49 (MD5)
Previous issue date: 2011 / Resumo: Esse trabalho concentra os estudos na investigação das propriedades de resistência a tração e alongamento do compósito de Politetrafluoretileno (PTFE) com 60% de bronze após a substituição do tipo de PTFE utilizado na formulação desse compósito. Atualmente esse compósito utiliza PTFE convencional na formulação e o objetivo é alterar para PTFE modificado. A motivação para essa alteração deveu-se ao fato que o PTFE convencional apresenta disponibilidade limitada dificultando o desenvolvimento dos segmentos que utilizam os compósitos de PTFE com 60% de bronze. A escolha do PTFE modificado para a substituição do PTFE convencional na formulação do compósito de PTFE com 60% de bronze deveu-se ao fato que polímero puro de PTFE modificado apresenta propriedades mecânicas e químicas superiores ao polímero puro de PTFE convencional, além de não apresentar limitações de disponibilidade, possibilitando a continuidade do crescimento dos segmentos industriais. A escolha do compósito de PTFE com 60% de bronze deveu-se ao fato que essa formulação é a mais empregada no segmento automobilístico para a fabricação de anéis para amortecedores e retentores. Após a substituição da resina de PTFE, os resultados demonstraram que o compósito de PTFE modificado com 60% de bronze apresentou propriedades inferiores ao compósito fabricado com PTFE convencional. A queda dessas propriedades pode estar relacionada com possíveis micros fissuras na estrutura do compósito em virtude de ar preso durante o processo de fabricação / Abstract: This work focuses on research studies of the properties of tensile strength and elongation of the composite of Polytetrafluoroethylene (PTFE) with 60% bronze after replacing the type of PTFE used in the formulation of this compound. Currently, this composite uses conventional PTFE in the formulation and the objective is to change to modified PTFE. The motivation for this change was due to the fact that the conventional PTFE has limited availability hindering the development of the segments that use the PTFE composite with 60% bronze. The choice of PTFE modified PTFE to replace the conventional formulation of the composite with 60% PTFE bronze was due to the fact that pure polymer modified PTFE has superior mechanical and chemical properties of the pure polymer PTFE conventional, and not present availability limitations, enabling the continued growth of industries. The choice of the composite with 60% PTFE bronze due to the fact that this formulation is the most used in the automotive sector for the manufacture of rings and seals for shock absorbers / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
|
373 |
Use of fluorescence in the performance evaluation of adhesive systems = Uso da fluorescência na avaliação do comportamento de sistemas adesivos / Uso da fluorescência na avaliação do comportamento de sistemas adesivosAraújo, Cíntia Tereza Pimenta de, 1968- 21 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartinni Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:09:59Z (GMT). No. of bitstreams: 1
Araujo_CintiaTerezaPimentade_D.pdf: 9367664 bytes, checksum: 6c7161dae0f158a143f829e530249b20 (MD5)
Previous issue date: 2013 / Resumo: A microscopia confocal de varredura a laser (MCVL) é um recurso de visualização microscópica que permite a análise de materiais ou estruturas com requisitos mínimos de preparação de amostras de modo não destrutivo. Assim, os objetivos deste estudo foram: avaliar a influência da incorporação do corante fluorescente Rodamina B (R) nas propriedades mecânicas resistência coesiva (RC), módulo de elasticidade (ME) e resistência à flexão (RF) de 2 sistemas adesivos, o autocondicionante Clearfil SE Bond e o convencional Scotchbond Multi-Purpose (estudo 1); validar o método modificado de microtração (?TBS), em que micro-amostras de secção transversal de 0,09 mm2 foram testadas e verificar a influência da R na resistência à união a dentina e integridade interfacial através de microscopia confocal (estudo 2). Para avaliar a influência do corante, 0,16 mg/ml de R foram incorporados aos adesivos constituindo assim dois grupos para cada adesivo: grupos dos adesivos corados e não corados totalizando 4 grupos experimentais. Para a análise da RC, E e RF, os corpos de prova foram confeccionados a partir de uma matriz de silicone por adição. Sobre a matriz, foram dispensados 10 ?L de adesivo variando de acordo com cada grupo de adesivos corados e não corados. RC (n= 10), E e RF (n= 5) foram avaliadas em máquina de ensaio universal a 0,5 mm/min, até a ruptura da amostra. Para visualização em microscopia confocal e análise da resistência à união os adesivos foram aplicados à superfície plana da dentina oclusal de 32 pré-molares humanos. Após a realização dos procedimentos adesivos, realizaram-se as restaurações (blocos de 16 mm2) com Charisma Opal (Kulzer - cor A3). Em seguida, para a realização do teste modificado de microtração, micro-amostras em forma de palito (secção transversal 0,09 mm2) foram confeccionadas. Previamente ao ensaio mecânico, foi realizada através de MVCL a análise micromorfológica das microamostras dos grupos de adesivos corados. Posteriormente a resistência à união foi mensurada através do ensaio modificado de microtração a velocidade de 0,5 mm/min em máquina de ensaio universal. Os dados de todos os testes avaliados foram submetidos à análise de variância dois fatores. Os resultados mostraram que o comportamento dos sistemas adesivos investigados não se modificou, independente da presença do corante, pois não foram observadas diferenças significativas nas propriedades mecânicas estudadas: resistência à união, resistência coesiva, resistência flexural, módulo de elasticidade, bem como a integridade interfacial. A preparação de micro-amostras não comprometeu os resultados do ensaio de resistência adesiva. De acordo com os resultados obtidos e análise dos parâmetros: coeficiente de variação, porcentagem de padrão de fratura e incidência de falhas prematuras, concluiu-se que o teste modificado de microtração foi considerado um método confiável para a avaliação da resistência à união de sistemas adesivos. A técnica de visualização microscópica confocal produziu informações detalhadas da interface adesiva e pode ser bem indicada para a avaliação da efetividade de união de sistemas adesivos. Desta forma, é possível associar ambas as metodologias obtendo-se uma avaliação mais realista e confiável dos materiais restauradores / Abstract: The confocal laser scanning microscopic (CLSM) is a tool of visualization that allows microscopic analysis of materials or structures labeled with fluorescent dyes with minimal requirements of specimen's preparation nondestructively. The aims of this study were: to evaluate the influence of incorporation of fluorescent dye Rhodamine B (R) in the properties mechanical: cohesive strength (CS), elastic modulus (E) and flexural strength (FS) of the selfetching Clearfil SE Bond and etch-and-rinse Scotchbond Multi-Purpose (Study 1); validating the modified microtensile method using micro-specimens cross section of 0.09 mm2 (?TBS) and evaluate the influence of R in bond strength in dentin and interfacial integrity by confocal microscopy (study 2). To evaluate the influence of the dye, 0.16 mg/ml of R were incorporated into adhesives thus forming two groups for each adhesive: groups of labeled adhesives and no-labeled totaling 4 experimental groups. For the analysis of CS, E and FS the specimens were made from a silicone matrix. About the matrix were 10 ?L dispensed adhesive varying according to each group of adhesives stained or not. CS (n = 10), E and FS (n = 5) were evaluated in a universal testing machine at 0.5 mm/min until failure of the specimen. For visualization in confocal microscopy and bond strength analysis (n = 8), the adhesives were applied to the occlusal dentine surface 32 of human premolars. After procedures adhesives, composite crowns approximately (16 mm2) were built up with Charisma Opal (Kulzer - color A3). Then for testing modified microtensile, micro-specimens beam-shaped were prepared. Prior to mechanical testing micromorphological analysis of micro-sticks of the groups of labeled adhesives was performed using CLSM. Subsequently bond strength was measured using the modified microtensile test in a universal testing machine speed of 0.5 mm/min. The results showed that the behavior of the adhesive systems investigated did not change regardless of the presence of the dye, as there were no significant differences in mechanical properties studied: bond strength, tensile strength, flexural strength, modulus of elasticity, as well as interfacial integrity. The preparation of micro-specimens did not affect the results of the bond strength test. According to the analysis results and parameters: coefficient of variation percentage of fracture pattern and incidence of early failures, it is concluded that the modified microtensile test was considered a reliable method for evaluating the bond strength of adhesive systems. The confocal microscopic visualization technique yielded detailed information of the adhesive interface and can be well suited for evaluating the effectiveness of adhesive systems. Thus, it is possible to associate both methods give a more realistic and reliable adhesive restoration on the presence of fluorescent dye / Doutorado / Dentística / Doutora em Clínica Odontológica
|
374 |
Effect of pre-etching to enamel and dentin on bond strength and interfacial morphology of different adhesives systems = Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivos / Efeito do pré-condicionamento ácido do esmalte da dentina na resistência de união e morfologia de interface de diferentes sistemas adesivosFreitas, Marcela Santiago, 1987- 21 August 2018 (has links)
Orientadores: Mirela Sanae Shinohara, Mário Fernando de Góes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:51:52Z (GMT). No. of bitstreams: 1
Freitas_MarcelaSantiago_M.pdf: 38797129 bytes, checksum: 16869befa66eba198d1cb13ad5c9ac1d (MD5)
Previous issue date: 2013 / Resumo: Estudos mostram que a resistência de união (RU) alcançada pelos sistemas adesivos autocondicionantes em superfície de esmalte pré-condicionado é significativamente maior se comparada aos valores obtidos em esmalte não condicionado. A partir destas evidências, este estudo teve como objetivo avaliar a RU e a morfologia da interface adesiva (MI) em esmalte e dentina de um adesivo autocondicionante de passo único multi-mode e um adesivo autocondicionante de dois passos com e sem pré-condicionamento ácido da superfície comparado a dois sistemas adesivos de condicionamento total, de dois e três passos. Terceiros molares humanos recém-extraídos foram seccionados para obtenção de superfícies planas em esmalte e dentina, as quais foram desgastadas com lixa SiC #600 para padronização da smear layer. Estas amostras foram divididas aleatoriamente em 6 grupos: (SBU) Scotchbond Universal; (SBUcond) SBU précondicionado; (CSE) Clearfil SE Bond; (CSEcond) CSE pré-condicionado; (SBMP) Scotchbond Multi-Purpose; e (EX) Excite F. Os grupos de condicionamento total e os autocondicionantes a serem avaliados com pré-condicionamento receberam a aplicação do ácido fosfórico por 15s em dentina e 30s em esmalte. Todos os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Em seguida, um bloco de resina composta (Filtek Supreme Plus) foi construído incrementalmente sobre cada superfície preparada para o teste de RU, e para a MI, as superfícies foram restauradas com resina flow (Filtek Z-350 Flowable Restorative) formando um "sanduíche", de esmalte ou dentina. Após 24h, para avaliação da RU, as amostras foram seccionadas em palitos com área transversal de 0,8mm2 e submetidos ao teste de microtração com velocidade de 1,0mm/min. Os resultados foram analisados estatisticamente pelos testes one-way ANOVA e Fisher's PLSD (?=0.05) e os padrões de fratura analisados em Microscopia Eletrônica de Varredura (MEV). Para análise da MI, duas amostras de cada grupo foram incluídas em resina epóxica, polidas e observadas em MEV. Para esmalte, os resultados de RU mostraram que o SBUcond e CSEcond obtiveram os maiores valores, seguidos dos grupos SBMP, SBU e CSE que não apresentaram diferenças entre si. O grupo EX obteve os menores valores comparados aos outros grupos. Na análise da MI, os grupos SBUcond e CSEcond apresentaram nítidas extensões do adesivo penetrado no esmalte desmineralizado, semelhante aos sistemas de condicionamento total. Já para dentina, os resultados de RU mostraram que o condicionamento ácido prévio diminuiu significativamente os valores de RU dos sistemas autocondicionantes. Os maiores valores foram obtidos pelo SBU, CSE e SBMP, com valores de RU estatisticamente equivalentes entre si. Como em esmalte, o sistema adesivo EX obteve os menores valores. A análise em MEV da MI mostrou que o condicionamento prévio da dentina com adesivos autocondicionantes forma uma camada híbrida mais espessa com formação de tags resinosos, semelhantes aos sistemas adesivos de condicionamento total. Pode-se concluir que em esmalte, o condicionamento prévio aumentou significativamente os valores de RU para os sistemas autocondicionantes. Contudo, estes sistemas adesivos não apresentaram diferença estatística do adesivo convencional SBMP. E para dentina, o pré-condicionamento dos adesivos autocondicionantes diminuiu significativamente os valores de RU, entretanto, os valores de SBUcond não foram diferentes significativamente dos obtidos pelo sistema adesivo convencional SBMP / Abstract: Studies show that the bond strength (BS) achieved by self-etching adhesive systems on pre-etched enamel surface is significantly higher compared with the values obtained on unetched enamel. From this evidence, this study aimed to assess the BS and morphology of the adhesive interface (AI) on enamel and dentin of a one-step self-etching adhesive multi-mode and a two-step selfetching adhesive with and without pre-etching of surface compared with two totaletching adhesive systems, two and three steps. Recently extracted human third molars were sectioned to obtain flat surfaces in enamel and dentin, which were ground with #600 SiC sandpaper to standardize the smear layer. These samples were randomly assigned into 6 groups: (SBU) Scotchbond Universal; (SBU-et) SBU pre-etched; (CSE), Clearfil SE Bond, (CSE-et) CSE pre-etched; (SBMP) Scotchbond Multi-Purpose, and (EX) Excite F. The groups total-etching and selfetching to be evaluated with pre-etching received the application of phosphoric acid for 15s in dentin and 30s in enamel. All adhesive systems were applied according to manufacturers' recommendations. Then, a block of composite resin (Filtek Supreme Plus) was constructed incrementally on each surface prepared for BS testing. For AI, the areas were filled with flowable resin (Filtek Flowable Restorative Z-350) forming a "sandwich" of enamel or dentin. After 24 hours, to review the BS, the specimens were sectioned into sticks with cross-sectional area of 0.8mm² and submitted to microtensile test at a speed of 1.0mm/min. The results were statistically analyzed by one-way ANOVA test and Fisher's PLSD (?=0.05) and fracture patterns were analyzed through Scanning Electron Microscopy (SEM). For analysis of AI, two samples from each group were embedded in epoxy resin, polished and observed through SEM. For enamel, the results of BS showed that SBU-et and CSE-et obtained the highest values, followed by SBMP groups, SBU and CSE with no differences among them. The EX group obtained the lowest values of all other groups. In the analysis of AI, and CSE-et and SBU-et groups showed sharp tag extensions of the adhesive penetrated in the demineralized enamel, similar to total-etching systems. As for dentin, BS results showed that acid etching significantly reduced the BS values of self-etching systems. The highest values were obtained by the SBU, CSE and SBMP with BS values statistically equivalent to each other. As in enamel, the adhesive system EX obtained the lowest values. SEM analysis showed that BS for pre-etched dentin with selfetching adhesive forms a thicker hybrid layer with resin tags formation, similar to total-etching adhesive systems. It can be concluded that on enamel, the preetching significantly increased BS for self-etching systems. However, these adhesive systems showed no statistical difference from conventional adhesive SBMP. And to dentin, pre-etching of sel-etching adhesives significantly reduced BS, however, SBU-et values were not significantly different from those obtained by the conventional adhesive system SBMP / Mestrado / Dentística / Mestra em Materiais Dentários
|
375 |
Avaliação da resistencia ao cisalhamento da resina composta e do cimento de ionomero de vidro na fixação de braquetes metalicosValdrighi, Heloisa Cristina 06 October 2002 (has links)
Orientador: Darcy Flavio Nouer, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T02:37:45Z (GMT). No. of bitstreams: 1
Valdrighi_HeloisaCristina_D.pdf: 2776014 bytes, checksum: e51a23872c56c05e6ae98411da802807 (MD5)
Previous issue date: 2002 / Resumo: O objetivo desta pesquisa foi avaliar a resistência ao cisalhamento da resina composta e do cimento de ionômero de vidro na fixação de diferentes tipos - de bráquetes metálicos (Morelli, Abzil-Lancer, Dentaurum e GAC). Foram utilizados 120 pré-molares humanos. As faces vestibulares de 80 prémolares receberam condicionamento ácido e os bráquetes foram fixados utilizando Concise Ortodôntico e Transbond XT, enquanto em outros 40 prémolares, os bráquetes foram fixados com Fuji Ortho LC. As amostras foram armazenadas em solução de soro fisiológico a 0,9% a 37°C por 24 horas. Em seguida, foram submetidas ao teste de resistência ao cisalhamento em uma máquina Instron, com velocidade de 0,5mm/min. Os resultados foram submetidos à análise de variância e ao teste de Tukey (p<0,05). Associando sistemas adesivos aos respectivos bráquetes, os resultados mostraram que: a) com o Concise ortodôntico, a resistência (kgf/mm 'POT. 2¿)do bráquete GAC (1,698) foi significantemente maior que os bráquetes Abzil-Lancer (1,353), Dentaurum (1,293) e Morelli (0,828), que apresentou a menor média; b) com o Transbond XT, observou-se que os bráquetes Dentaurum (1,082) e GAC (1,225) apresentaram médias significantemente maiores do que os bráquetes Morelli (0,583) e Abzil-Lancer (0,621); e, c) com o Fuji Ortho LC, não foram observadas diferenças entre as médias dos diferentes bráquetes testados (Morelli=0,301, Abzil-Lancer=0,309, Dentaurum 0,230 e GAC=0,338). Os autores concluíram que o Concise Ortodôntico apresentou maiores valores de resistência ao cisalhamento, seguidos do Transbond XT e Fuji Ortho LC. O bráquete GAC apresentou maior resistência em todos os materiais e o bráquete Morelli a menor resistência / Abstract: The aim of this study was to evaluate the shear bond strength of composites and glass ionomer cement of different metallic brackets bonding (Morelli, Abzil-Lancer, Dentaurum e GAC). One hundred and twenty human premolars were used. For eighty premolars, the vestibular faces were etched and were bonded to enamel surface using Concise Ortho and Transbond XT, whereas in others forty premolars the brackets were bonded with Fuji Ortho LC in the vestibular faces without acid etching. All samples were stored in fisiologic solution 0,9% at 37°C for 24 hours. Afier the sample were submitted to shear bond strength in an Instron at a crosshead speed of 0.5 mm/min. The results were submitted to ANOVA and Tukey's test (p<0.05). Associating adhesives systems to respective brackets, the data indicated that: a) with Concise Ortho, the strengths (kgt/mm¿POT. 2¿) of GAC bracket (1.698) was significant1y higher than Abzil-Lancer (1.353), Dentaurum (1.293) and Morelli (0.828) brackets; b) with Transbond XT, Dentaurum (1.082) and GAC (1.225) brackets showed average higher than Morelli (0.583) and Abzil-Lancer (0.621); and, c) with Fuji Ortho LC, it wasn't showed difference between the average of different brackets tested (Morelli=0.301, Abzil-Lancer=0.309, Dentaurum 0.230 and GAC=0.338). The authors concluded that the Concise Ortho showed highest shear bond strength values followed by Transbond XT and Fuji Ortho LC. The GAC bracket showed higher strength in alI adhesives systems and the Morelli bracket the lowest strength / Doutorado / Doutor em Ortodontia
|
376 |
Influencia do grau de mineralização do substrato dentinario na resistencia a microtração de tres sistemas adesivosErhardt, Maria Carolina Guilherme 31 January 2003 (has links)
Orientador: Luiz Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T17:59:19Z (GMT). No. of bitstreams: 1
Erhardt_MariaCarolinaGuilherme_M.pdf: 5117640 bytes, checksum: d255d8edb48804d7128e30ab7907508a (MD5)
Previous issue date: 2003 / Resumo: O objetivo deste estudo in vitro foi determinar a influência de superfícies dentinárias desmineralizadas, normais e hipermineralizadas na resistência adesiva (RA) dos sistemas adesivos Clearfil Liner Bond 2V / Kuraray Co. (CLB), Single Bond /3M (SB) e OptiBond Solo P/us / Kerr (OSP). Noventa incisivos bovinos foram selecionados, tendo suas superfícies vestibulares desgastadas com lixas de carbeto de silício em granulação decrescente. Os dentes foram aleatoriamente separados em três grupos, sendo submetidos a diferentes padrões de ciclagem de pH: G1 - dentina desmineralizada (DD)i G2 - dentina hipermineralizada (DH) e G3 - dentina normal (DN). Cada grupo, com seus respectivos padrões de superfície, foi novamente dividido por aleatorização em três subgrupos, para que recebessem a aplicação de um dos três sistemas adesivos, de acordo com a recomendação dos fabricantes. Blocos de compósito Filtek Z250 / 3M com altura de 5 mm foram incrementalmente confeccionados, e após 24 h de armazenagem em água destilada a 37 °C, os dentes foram preparados para serem submetidos ao teste de microtração. Dispostos em cortadeira metalográfica de precisão, os dentes foram seriadamente seccionados em fatias de 1,0 mm de espessura paralelamente ao longo eixo dental. Em seguida, dispositivos hour glass foram manualmente confeccionados com o auxílio de pontas diamantadas de granulação fina em alta rotação, com área adesiva final de 0,8 mm2. Os espécimes foram afixados individualmente em um dispositivo de microtração (MT Jig), acoplada em máquina de ensaio universal / EMIC, com velocidade de 0,5 mm/min. Após o teste, as duas porções fraturadas foram avaliadas em microscópio óptico (40x). Os valores de RA foram submetidos aos testes de análise de variância (ANOVA 2 fatores) e Tukey, com nível de significância de 5%. Os valores médios, expressos em MPa, foram: DN;SB= 31,05; DN/OSP= 24,49; DH;SB= 23,97; DH/CLB= 19,32; DN/CLB= 19,00; DH/OSP= 17,84; DD/CLB= 15,81; DD;SB= 13,62i DD/OSP= 5,22. Houve interação estatística entre os sistemas adesivos e os tipos de dentina avaliados. Em DN, os sistemas adesivos SB e OSP foram significativamente mais efetivos que o adesivo CLB. Em DD, os adesivos SB e CLB apresentaram os maiores valores de RA. Em DH, todos os sistemas adesivos se comportaram de maneira semelhante. Não foi possível observar um benefício claro advindo da utilização de um único sistema adesivo em todos os níveis de mineralização dentinária / Abstract: The purpose of this in vitro study was to investigate the effect of dentin mineralization level: demineralized, normal or hypermineralized, on microtensile bond strength of the adhesive systems Clearfil Liner Bond 2V / Kuraray Co. (CLB), Single Bond / 3M (SB) and OptiBond Solo Plus / Kerr (OSP). 90 freshly extracted incisive bovine teeth were selected, thoroughly cleaned and mechanically polished with wet silicon carbide papers. Teeth were randomly assigned into three groups, which were submitted to different pH-cycling models: Group I - demineralized dentin (DD); Group II - hypermineralized dentin (HD) and Group III normal dentin (ND). Each group, with its specific mineralization pattern, was randomly reassigned into three subgroups, in order to receive one of each adhesive application, according to manufacturers' instructions. Resin "crowns" with 5 mm high were incrementally constructed with Filtek Z250 /3M composite resin, and after 24 h of storage in distilled water at 37°C, teeth were prepared to micro-tensile testing. Samples were serially sectioned on a precision cutter in 1 mm slices, parallel to the dental long axis; and with diamond points, the hour glass devices were trimmed resulting in a cross-sectional area of 0.8 mm2. Each specimen was indMdual1y tested on a microtensile device (MT Jig) attached to a universal testing machine / EMIC with a crosshead speed of 0.5 mm/min. After testing, each specimen was visually evaluated. The bond strengths were statistically evaluated with two-way ANOVA and Tukey's test (p<0.05). The mean values obtained, recorded in MPa, were: ND;SB= 31.05; ND/OSP= 24.49; HD;SB= 23.97; HD/CLB= 19.32; ND/CLB= 19.00; HD/OSP= 17.84; DD/CLB= 15.81; DD;SB= 13.62; DD/OSP= 5.22. The statistical analysis showed a significant (p<0.05) interaction between the adhesive systems and the dentin substrates evaluated. SB and OSP presented the higher tensile bond strength values on ND. In terms of tensile bond strengths to DD, the highest mean values originated from SB and CLB. Regarding the HD, no differences were found among the adhesive systems evaluated. It could not be observed a real benefit from a unique adhesive system in all dentin mineralization levels / Mestrado / Dentística / Mestre em Clínica Odontológica
|
377 |
Effet du confinement plastique sur la stabilité mécanique des défauts dans les gazoducs : vers l'utilisation des éprouvettes SENT pour la caractérisation de la résistance à la fissuration des défauts dans les gazoducs / impact of the plastic constraint on the mechanical stability of defects in pipelinesBurlot, Philippe 16 January 2015 (has links)
Dans le cadre de cette étude, l'influence du confinement de la plasticité en pointe de fissure sur la ténacité mesurée du matériau a été abordée. Après une étude de la microstructure du matériau, une étude expérimentale approfondie de son comportement mécanique a été mise en oeuvre. Un modèle complexe combinant un écrouissage anisotrope avec un endommagement lui aussi anisotrope comprenant une prise en compte de l'éffet de géométrie par le paramètre de Lode a été mis en place. L'ensemble des travaux se termine par une étude d'un cas concret de gazoduc entaillé soumis à une pression interne jusqu'à éclatement duquel on peut conclure que l'éprouvette de type SENT est plus adaptée que les autres pour l'étude du comportement de structures tubulaires minces. / In this thesis the influence of plastic constraint at a crack tip on the mesured tough-ness of a material has been evaluated. After a study of the microstructure of the material, an ex-perimental study of its mechanical behaviour was made. A complex model combining an anisotrope hardening with an anisotrope damage law including a geometry contridution by means of the Lode parameter was then used. The porject ends with a study of the bursting test of a precracked line pipe. We can conclude from this test that the SENT specimen is more suitable for the study of thin tubes.
|
378 |
Modifying kraft pulping to produce a softwood pulp requiring less energy in tissue paper productionRahman, Hafizur January 2018 (has links)
Modification of softwood kraft pulp by the addition of either polysulfide (PS) or sodium borohydride (NaBH4) has been shown to increase the pulp yield due to a higher retention of glucomannan. The pulps with higher yield gave a paper with higher tensile index than reference pulp, especially at lower degrees of refining. The higher yield pulps also showed a greater porosity of the fibre wall, indicating an increase in the swelling potential of the fibres. This can lead to increased fibre flexibility and increased joint strength between the fibres and to the higher handsheet tensile index. However, the swelling increase associated with the higher hemicellulose content could also make dewatering more challenging because of the higher water retention of the pulp. The results of this study show however that the positive influence of the increase in yield (fewer fibres and a more open sheet structure) dominates over the negative influence of the higher hemicellulose content on the dewatering properties, especially at lower refining energy levels. Studies simulating full-scale tissue machine dewatering conditions showed that pulps with a higher yield and a higher hemicellulose content had a higher tensile index at the same dryness. Moreover, the same dryness level was achieved in a shorter dwell-time. A given tensile index was also achieved with less refining energy. Increasing the yield and hemicellulose content by the addition of either an oxidizing or a reducing agent in the softwood kraft pulping process thus has a potential for giving high quality fibres for tissue paper production with less refining energy and lower drying energy costs. / <p>Vid tidpunkten för framläggningen av avhandlingen var följande delarbeten opublicerade: delarbete 2 inskickat.</p><p>At the time of the defence the following papers were unpublished: paper 2 submitted.</p>
|
379 |
LONGEVIDADE DA UNIÃO DE SISTEMAS ADESIVOS UNIVERSAIS EM DENTINA HÍGIDA E AFETADA / BONDING LONGEVITY OF UNIVERSAL ADHESIVE SYSTEMS ON SOUND AND CARIES-AFFECTED DENTINFollak, Andressa Cargnelutti 29 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A new generation of adhesive systems are currently available on market. They were reported on the literature as universal adhesives or multimode adhesives . These adhesives are versatile, as they can be use in either etch-and-rinse or self-etch strategy. However, only a few data is available about long-term bonding behavior of universal adhesive systems. Then, the aim of this study is to evaluate immediate and six months bond strength of different universal adhesive systems on sound and caries-affected dentin, either on etch-and-rinse or self-etch strategies. The adhesive systems tested were: Scotchbond Universal (3M ESPE), All-Bond Universal (Bisco), Prime & Bond Elect (Denstply Caulk), Adper Single Bond 2 (3M ESPE) and Clearfil SE Bond (Kuraray Noritake Dental). All adhesive systems were applied under manufacturer s instructions and a composite block was build up on dentin surfaces. Caries-affected dentin was artificially induced by pH-cycling (8h immersed on demineralizing solution and 16h on remineralizing solution, for 14 days). Stick shaped specimens (0,8 mm²) were obtained to be submitted to microtensile test at immediate time or after 6 months of storage. Bond strength data (MPa) were analyzed by three-way repeated measures ANOVA and post-hoc Tukey test (α= 5%). Analysis were performed for each substrate separately. On sound dentin, the etching strategy did not influence bond strength of universal adhesives and no significant statistical differences were found for bond strength values after 6 months of water storage. On caries-affected dentin, adhesive systems also showed similar results regardless etching strategies. However, significant reduction in bond strength values was found after six months. The etching strategy did not influence bond strength performance of universal adhesives on dentin substrate, although the long-term bond strength is decreased on caries-affected dentin. / Recentemente foram introduzidos no mercado uma nova geração de adesivos, reportados pela literatura como adesivos universais ou multi-modo . Esses adesivos são materiais versáteis, podendo ser utilizados tanto na técnica autocondicionante como na técnica com condicionamento ácido prévio. No entanto, pouco sabe-se ainda sobre o comportamento desses adesivos universais em relação à longevidade da adesão. Então, o objetivo deste estudo foi avaliar a resistência de união imediata e após 6 meses de diferentes adesivos universais em dentina hígida e afetada, usando as estratégias de condicionamento ácido prévio e autocondicionante. Os sistemas adesivos testados foram: Scotchbond Universal (3M ESPE), All-Bond Universal (Bisco), Prime & Bond Elect (Denstply Caulk), Adper Single Bond 2 (3M ESPE) e Clearfil SE Bond (Kuraray Noritake Dental). Todos os adesivos foram aplicados seguindo as recomendações dos fabricantes e um bloco de resina composta foi construído sobre a dentina. A dentina afetada foi obtida artificialmente através de ciclagem de pH (8 horas em solução desmineralizante e 16 horas em solução remineralizante, por 14 dias). Espécimes em forma de palitos foram obtidos (0,8 mm²) para serem submetidos ao teste de microtração imediatamente ou após 6 meses de armazenamento. Os dados obtidos em MPa foram analisados por análise de variância de 3 fatores e teste de contraste de Tukey (α= 5%). A análise foi realizada separadamente para cada substrato. Em dentina hígida, a estratégia de condicionamento não teve influência na resistência de união dos adesivos universais e não houve diferença estatisticamente significante entre a resistência de união imediata e após 6 meses. Em dentina afetada, os sistemas adesivos apresentaram resultados similares, independente da estratégia de condicionamento. No entanto, houve uma significativa redução na resistência de união após 6 meses. Assim, a estratégia de condicionamento não influencia a resistência de união dos adesivos universais em dentina, porém a resistência de união a longo prazo é reduzida em dentina afetada.
|
380 |
Etude et optimisation de la réparation des composites stratifiés par collage des patchs externes / Study and optimization of the repair of composite laminates by bonding external patchesCheng, Pengcheng 15 December 2010 (has links)
L’étude réalisée dans le cadre de cette thèse représente une recherche sur la durabilité de la réparation par collage de patchs externes de structures composites endommagées. Le comportement des réparations sollicitées en traction a été étudié. Les approches expérimentale et numérique ont été réalisées. La qualité et la répétitivité des réparations dépendent fortement du savoir-faire employé durant leur mise en œuvre. A ce titre, un protocole de fabrication précis a été établi et validé. Ce protocole a ensuite été appliqué strictement dans l’ensemble de l’étude. L’effet de la géométrie des patchs sur la performance des réparations en traction a été discuté. De plus, deux séries de patchs présentant des rigidités de membranes et des séquences d’empilement différentes ont été testées. Pratiquement, plusieurs méthodes de contrôle ont été appliquées pour localiser l’initiation de l’endommagement et suivre son évolution jusqu’à la rupture final. L’observation des scénarios d’évolution de l’endommagement a conduit à proposer trois modèles phénoménologiques permettant l’élaboration et la validation d’un modèle numérique.Le modèle numérique proposé a été validé grâce à la corrélation avec les résultats expérimentaux. Ensuite, ce modèle a été appliqué pour réaliser une étude paramétrique. Les résultats obtenus ont permis de proposer un modèle d’aide à la conception et à l’optimisation des structures composites réparées. Ce modèle fournit des informations intéressantes sur la meilleure combinaison des paramètres de réparation à utiliser. / The study in this thesis represents research on the durability of the repair of damaged composite structures by bonding external patches. The behaviour of the remedies sought in tension was investigated. The experimental and numerical approaches have been made.The quality and repeatability of repairs depends heavily on skills used during their installation works. As such, a specific manufacturing protocol was established and validated. This protocol was then applied strictly throughout the study. The effect of patch geometry on the performance of repair in tension has been discussed. In addition, two sets of patches with the different membrane stiffness and stacking sequences were tested. Practically, several control methods were applied to locate damage initiation and follow its evolution until the final rupture. Observing damage evolution scenarios has led to propose three phenomenological models for the development and validation of a numerical model.The proposed numerical model has been validated through correlation with experimental results. Then, this model was applied to perform a parametric study. The results obtained allowed to propose a model to help design and optimization of repaired composite structures. This model provides interesting information on the best combination of repair settings.
|
Page generated in 0.0576 seconds