• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 391
  • 337
  • 86
  • 52
  • 37
  • 21
  • 18
  • 14
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • Tagged with
  • 1175
  • 507
  • 236
  • 225
  • 224
  • 181
  • 176
  • 157
  • 153
  • 120
  • 109
  • 101
  • 98
  • 94
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
561

Aderência de revestimentos externos de argamassa em substratos de concreto : influência das condições de temperatura e ventilação na cura do chapisco / External mortar rendering bond in concrete substrates : influence of temperature and ventilation conditions during the slurry layer curing

Moura, Cristiane Borges January 2007 (has links)
A prevenção de manifestações patológicas em revestimentos de argamassa, em especial os descolamentos, é refletida no interesse das empresas construtoras e pesquisadores por um maior conhecimento das propriedades dos elementos constituintes do sistema, bem como dos fatores externos. Destes pode-se citar as variáveis que intervêm nos mecanismos de aderência, porém que não são controláveis, como a temperatura, umidade e ventilação. Neste contexto, o presente trabalho objetiva analisar a influência da ação do vento e da temperatura elevada durante a cura da argamassa de chapisco na aderência dos revestimentos externos de argamassa aplicados em substratos de concreto. Foram moldados prismas nas dimensões 40x45x10cm, com resistência aos 28 dias de 37MPa. Utilizou-se 3 argamassas de chapisco, uma dosada em obra com traço 1:5,67 (em massa com areia seca) e outras duas industrializadas de diferentes fabricantes. Também foram utilizadas 3 argamassas de revestimento, uma dosada em obra com traço 1:0,78:6,5 (em massa com areia seca), e outras duas industrializadas de diferentes fabricantes, sendo os mesmos das argamassas de chapisco. Combinou-se os tipos de argamassa de chapisco e revestimento juntamente com o modo de preparo de cada para a composição de diferentes sistemas de revestimento, num total de 90 combinações aplicadas em 45 prismas. Em todos eles, uma das faces recebia a ação do vento durante a cura de três dias da argamassa de chapisco e em 18 deles ambas as faces recebiam também a ação da temperatura de 40°C (os demais eram curados a 23°C). As argamassas de revestimento eram curadas durante 28 dias a uma temperatura de 23±2°C, sem a ação do vento. A umidade relativa do ar foi fixada em 60±5%. Foram realizados ensaios de resistência de aderência à tração do revestimento pela NBR 13528/95 e ensaios e de caracterização do concreto do substrato e das argamassas, estes últimos conforme prescrições da NBR 13281/05. Corpos-de-prova das argamassas de chapisco também foram curadas sob as mesmas condições a que os primas foram submetidas. As resistências médias de aderência obtidas variaram de 0,01 a 0,32MPa para chapiscos convencionais, 0,03 a 0,36MPa para os industrializados 1 e 0,06 a 0,33MPa para os industrizados 2. Com os dados obtidos fez-se análise estatística de variância (ANOVA). Os resultados demonstraram que a ação da ventilação e do calor influenciaram de forma significativa a resistência de aderência, sendo responsáveis por uma queda de 0,014MPa e 0,085MPa, respectivamente. Também se mostraram significativas as variáveis tipo de argamassa de chapisco e de revestimento. / The prevention of pathological manifestations in mortar renderings, in special case the detachment, reflected a concern of researches and construction companies aiming the knowledge of materials and rendering systems properties, as well as any other external factors. In this case, some variables that intervene (however not-controllable) in the bond strength mechanisms can be cited, as the temperature, humidity and ventilation. In this context, this work objective to analyze the influence of wind and high temperature during the slurry mortar cure and this relationship with the bond of external mortar renderings in concrete substrates. Concrete prisms of 40x45x10cm had been molded, with strength at 28 days of 37MPa. Three mixes of slurry mortars had been used, one proportioned in situ with a cement/aggregate proportion of 1:5,67(in mass) and two other different pre-mixed slurry mortars. Also three mixes of rendering mortars had been used, one proportioned in situ with a cement/limestone/aggregate proportion of 1:0,78: 6,5 (in mass), and two other different premixed mortars. A total of 45 prisms with 90 combinations (with the different slurry and rendering mortars, as well as different sample preparations) had been produced. For each prism, one of the rendered faces had been assayed simulating the wind action during the three days cure of the slurry mortar and in 18 from both them the faces covered also had been assayed with the action of 40ºC temperature (the others were cured at 23°C). Rendering mortars were cured at 23±2°C during 28 days, without wind influence. The humidity was fixed in 60±5%. The mortars (according NBR 13281/05) and concrete substrata characterization, as well as assays of tensile bond strength of the rendering (according NBR 13528/95) had been carried through. Samples of slurry mortars were also cured over the same conditions the prisms were submited. All data obtained had been statistically analyzed trough variance analysis (ANOVA). The results had demonstrated that the wind effect and the heat condition had influenced significantly the bond strength. The type of slurry or rendering mortar had also revealed significant effect in the bond strength.
562

Influência da umidade e temperatura intrabucais na resistência de união de sistemas adesivos convencionais de dois passos à dentina : estudo in situ.

Saraiva, Letícia Oliveira January 2008 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:30:00Z No. of bitstreams: 2 Dissertacao Leticia Saraiva2.pdf: 1296302 bytes, checksum: 1e07502c1e338a38db482de4808d32f7 (MD5) Dissertacao Leticia Saraiva1.pdf: 179952 bytes, checksum: cf1d7c8753ea10452ef96eb6607fddad (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:04:08Z (GMT) No. of bitstreams: 2 Dissertacao Leticia Saraiva2.pdf: 1296302 bytes, checksum: 1e07502c1e338a38db482de4808d32f7 (MD5) Dissertacao Leticia Saraiva1.pdf: 179952 bytes, checksum: cf1d7c8753ea10452ef96eb6607fddad (MD5) / Made available in DSpace on 2013-05-16T18:04:08Z (GMT). No. of bitstreams: 2 Dissertacao Leticia Saraiva2.pdf: 1296302 bytes, checksum: 1e07502c1e338a38db482de4808d32f7 (MD5) Dissertacao Leticia Saraiva1.pdf: 179952 bytes, checksum: cf1d7c8753ea10452ef96eb6607fddad (MD5) Previous issue date: 2008 / O presente estudo teve como objetivos avaliar o efeito das condições de temperatura e umidade relativa intrabucais na resistência de união à dentina de dois sistemas adesivos convencionais de dois passos (Single Bond 2/SB2 e One Step Plus/OSP), e avaliar a umidade e a temperatura presentes nas regiões de incisivos e molares superiores. Sessenta fragmentos dentários foram esterilizados, fixados em moldeiras de acetato individualizadas, e posicionados in situ em um voluntário para serem restaurados com resina composta, sendo aleatoriamente divididos em seis grupos, de acordo com o sistema adesivo e com a condição de temperatura e umidade: G1 – SB2 na condição ambiental de um consultório odontológico; G2 – SB2 na condição da região de incisivos; G3 – SB2 na condição da região de molares; G4 – OSP na condição ambiental de um consultório odontológico; G5 – OSP na condição da região de incisivos e G6 – OSP na condição da região de molares. Em todas as condições, foram obtidas e registradas a temperatura e a umidade relativa do ar no momento e no local em que as restaurações foram produzidas, usando um termo-higrômetro digital. Após ensaio de microtração, os dados do teste de resistência de união foram submetidos à análise estatística (ANOVA - 2 fatores/ Teste de Tukey, α=5%) e os valores médios em MPa foram: G1 = 20,2 (7,6); G2 = 23,0 (6,5); G3 = 22,7 (6,0); G4 = 29,0 (5,8); G5 = 29,7 (4,9) e G6 = 27,7 (4,8). Os resultados demonstraram que os grupos que utilizaram o OSP (G4, G5 e G6) apresentaram médias semelhantes entre si (p=0,67) e maiores do que os grupos que utilizaram o SB2 (G1, G2 e G3) (p=0,001), também semelhantes entre si (p=0,67). Foi observado que as condições de temperatura presentes nas regiões intrabucais (incisivos e molares) foram semelhantes entre si, e maiores que a condição ambiental do consultório odontológico. A condição de umidade na região de molares foi superior à condição na região de incisivos, e esta foi maior do que a condição presente no ambiente do consultório odontológico. As condições de temperatura e umidade intrabucais não influenciaram a resistência de união dos sistemas adesivos simplificados à dentina. O sistema adesivo One Step Plus apresentou melhores resultados que o sistema Single Bond 2, independentemente das condições de umidade e temperatura. / Salvador
563

Calibração de modelo numérico para simulação do comportamento mecânico de cabos poliméricos reforçados por fibra de carbono

Menezes, Eduardo Antonio Wink January 2015 (has links)
Cabos são componentes estruturais utilizados desde a antiguidade, principalmente em aplicações onde o carregamento axial é elevado, enquanto a flexão e torção são relativamente baixos. Exemplos de aplicação atuais incluem sustentação de pontes, ancoragem de plataformas offshore, elevadores, transporte em minas, guindastes, entre outros. O estudo de seu comportamento mecânico envolve fatores que agregam considerável complexidade na elaboração de modelos numéricos ou analíticos que representem seu comportamento. Dentre esses fatores se destacam as tensões de contato que surgem entre as pernas do cabo à medida que deslizam em relação às outras, a geometria helicoidal, a rotação das pernas em torno da alma do cabo ao ser estendido (i.e., variação do ângulo da hélice do cabo) além de, no caso de cabos compósitos, um comportamento anisotrópico. Tendo em vista a indisponibilidade de uma solução analítica completa para cabos compósitos, buscou-se através do presente trabalho calibrar um modelo numérico elaborado em software comercial de elementos finitos, contemplando fatores comumente desprezados pelos modelos analíticos simplificados. Foram executados ensaios de tração na alma de cabos de compósitos com fibras de carbono de geometria 1×10 (nove fios envolvendo a alma) para determinar o módulo de elasticidade longitudinal e utilizada a teoria da micromecânica para avaliar as demais constantes de engenharia. O cabo foi modelado em tração, onde uma extremidade foi engastada e a outra teve rotação restrita e deslocamento longitudinal livre, e também em flexão em quatro pontos, deixando uma das extremidades com rotação livre e a outra com rotação e deslocamento longitudinal livre, com os demais graus de liberdade restritos. Em seguida foi conduzida uma análise de sensibilidade das principais variáveis que governam o problema, de onde se concluiu que o passo do cabo, o diâmetro de seus fios e o módulo de elasticidade longitudinal são as mais relevantes. O desvio da deformação de ruptura em tração e do deslocamento em flexão obtidos numericamente em relação aos dados experimentais obtidos foi de 10,8 % e 14,6 %, respectivamente. Após o processo de calibração, que fez uso do método de Programação Linear Sequencial para buscar o valor das variáveis de projeto que minimizassem o erro entre os dados experimentais e numéricos, o desvio encontrado reduziu para 2,4 % e 0,1 %, respectivamente. / Wire ropes have been used since ancient times, especially in applications were the axial stress is high and flexural and torsional stresses are relatively low. Current application include bridges, offshore platforms, elevators, mine hoisting, cranes, among others. Study of their mechanical behavior encompasses many factors, bringing considerable complexity in the construction of numerical or analytical models that represent their behavior, including contact stresses between rods as they slide past one another, helical geometry, rotation of wires around the core when in extension (i.e. variation in helix angle) and also, for composite cables, the anisotropic behavior. In view of the unavailability of a comprehensive analytical solution, this work focuses on the calibration of a numerical model built on a finite element software incorporating factors commonly neglected by simplified analytical approaches. Tensile tests were performed on the core of carbon fiber composite cables, 1×10 geometry (nine rods surrounding the core), to evaluate its longitudinal elastic modulus and employed micromechanics theory to obtain the remaining engineering constants. The cable was then modeled under tensile stress, where one end was fully constrained and the other could not rotate but was free to move in the longitudinal direction. Under 4-point bending, where one end was free only to rotate, while the other was free to move in longitudinal direction and to rotate, whereas the remaining degrees of freedom were constrained. After that, sensitivity analysis of the main variables governing the problem was conducted, concluding that cable pitch, rod diameter and longitudinal elastic modulus of the rods are the most relevant parameters. Deviation between ultimate strain under tensile stress and displacement under bending numerically obtained with those from experiments were 10.8 % and 14.6 %, respectively. After the calibration process, which used Sequential Linear Programing to search for the design variables values that minimized error between numerical and experimental data, the finite element model could reproduce the tensile stress and bending behavior with deviations of 2.4 % and 0.1 %, respectively.
564

Estudo do comportamento mecânico de juntas soldadas de um aço de alta resistência mecânica

Carlesso, Rodrigo January 2017 (has links)
A aplicação de aços de alta resistência está fortemente difundida na indústria mecânica, principalmente em aplicações onde a redução de peso é importante, como por exemplo, a indústria de implementos rodoviários e maquinários agrícolas. Esta dissertação visa analisar a influência de diferentes aportes térmicos no comportamento microestrutural e mecânico de juntas soldadas através do processo MAG de modo a obter juntas com propriedades otimizadas. Para este estudo foram utilizadas chapas metálicas com espessura de 3 mm do aço de alta resistência e baixa liga USI LNE700. Os parâmetros nominais de energia de soldagem foram variados de acordo com os valores descritos pelo fornecedor SSAB. O processo de soldagem foi realizado com o auxílio de um sistema robotizado para manter a homogeneidade ao longo da junta, distância e posicionamento correto no comprimento total da junta soldada. Os ensaios para verificação do comportamento microestrutural e mecânico foram realizados com auxílio de microscopia ótica, perfis de microdureza e ensaios de tração. Buscaram-se utilizar aportes térmicos reduzidos para minimizar os efeitos de revenimento da martensita presente no metal de base, um dos principais responsáveis pela redução das propriedades mecânicas da junta soldada. Os resultados não mostraram significativa variações na microestrutura e propriedades de tração do material, porém o preenchimento da junta soldada formada apresenta um comportamento diretamente proporcional à energia de soldagem. / The application of high strength steels is strongly diffused in the engineering industry, especially in applications where weight reduction is important, such as the industry of agricultural machines and trailers industry. This investigation aims to analyze the influence of different heat inputs on microstructural and mechanical behavior of joint welded by GMAW in order to obtain joints with optimized properties. Sheet metal with a thickness of 3 mm high strength low alloy steel LNE700 (supplier Usiminas) were used. The welding energy was varied around the nominal value informed by the steel supplier SSAB for this study. The welding process was made using robotic system to maintain homogeneity along the joint, right distance and position during the total weld joint length. The microstructural and mechanical behaviors were performed with the optical microscope, microhardness profile and traction test. We attempted to use lower heat inputs to minimize the effects of tempering of martensite present in the base metal, a major contributor to the reduction of the mechanical properties of the welded joint. The results did not show significant microestructural and tensile properties variation, however, when the welding energy is increased, the welded joint penetration formed was increased as well.
565

Relação entre resistência à tração e à compressão de um solo fino artificialmente cimentado

Rosa, Daniela Aliati January 2013 (has links)
O melhoramento de solos com cimento Portland para utilização em camadas de base de fundações rasas, liners de proteção ambiental ou proteção contra erosão em barragens de terra entre outros mostra grandes vantagens econômicas, evitando a necessidade de substituição do solo natural bem como, a necessidade de uma área de despejo. A presente pesquisa tem por objetivo quantificar a relação entre resistência à tração e a compressão de um solo fino (caulim) artificialmente cimentado bem como, quantificar a influência da porosidade, teor de cimento e teor de umidade na resistência à tração das misturas caulim-cimento. Um programa experimental foi delineado com esse objetivo. Dentro da faixa de valores estudados, os resultados mostram que o teor de umidade (w) tem uma influência linear sobre a resistência à tração (qt), ou seja, quanto maior o teor de umidade maior a resistência à tração da mistura estudada. Por fim, a relação vazios/cimento (h/Civ) demonstrou ser válida no dimensionamento de misturas caulim-cimento à tração. A relação resistência à tração/resistência à compressão (qt/qu) não é única para o solo estudado. qt/qu varia em função do teor de umidade de modo não-linear. / The addition of Portland cement to soil in order to base layers for shallow foundations, liners for environmental protection or protection against erosion in earth damns has shown great economic advantages, avoiding the need of soil substitution as well as waste area. This research aim to quantify the relation between tensile and compressive strength for fine grained, artificially cemented soils as well as, quantify the influence of porosity, water content and cement content on tensile strength of kaolin-cement mixtures. An experimental program was designed with this objective. For the range of values studied, results show that water content (w) affects linearly tensile strength (qt) of specimens, bigger the water content bigger the tensile strength of the mixture studied. Besides that, the relation porosity/cement content (h/Civ) has demonstrated to be valid for designing kaolin-cement mixtures under tensile strength. The relation between tensile and compressive strength (qt/qu) is not unique for the soil studied. qt/qu seems to be a function of water content in a non-linear function.
566

Avaliação da resistência de união à dentina de restaurações estéticas indiretas: efeito da contaminação e limpeza dentinária

Freitas, Cláudia Regina Buainain de [UNESP] 27 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-27Bitstream added on 2014-06-13T19:20:26Z : No. of bitstreams: 1 freitas_crb_dr_arafo.pdf: 227207 bytes, checksum: 5b30a90b1e585db9913701192fdf3161 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de cimentos provisórios e de métodos de limpeza dentinária na resistência de união de restaurações indiretas em resina à dentina. Foram selecionados 21 terceiros molares recém extraídos e isentos de cárie. A parte da coroa dental correspondente ao esmalte foi removida expondo-se toda superfície dentinária. Os dentes foram divididos aleatoriamente em sete grupos experimentais de acordo com o cimento provisório e o método de limpeza dentinária utilizado: (G1-controle) não recebeu restauração provisória nem limpeza dentinária; (G2) cimentação provisória com Life e limpeza com pasta de pedra-pomes; (G3) cimentação provisória com Life (Kerr) e limpeza com jato abrasivo; (G4) nenhum procedimento de limpeza foi executado após cimentação com Life; (G5) cimentação provisória com Temp Bond e limpeza com pasta de pedra-pomes; (G6) cimentação provisória com Temp Bond (Kerr) e limpeza com jato abrasivo e (G7) nenhum procedimento de limpeza foi executado após cimentação com Temp Bond. Após uma semana de armazenamento em água, restaurações de Solidex (Shofu) foram cimentadas com adesivo Single Bond (3M ESPE) e cimento Rely X ARC (3M ESPE). Todos os produtos foram manipulados de acordo com as instruções do fabricante. Os dentes foram seccionados obtendo-se espécimes de 1,0 mm2 para realização de teste de microtração. Os valores obtidos foram submetidos à análise de variância e teste de Tukey. Os resultados indicaram que o grupo contaminado com hidróxido de cálcio sem realização da limpeza dentinária apresentou os menores valores de resistência e foi estatisticamente diferente do grupo onde não houve contaminação. Qualquer dos cimentos e métodos de limpeza utilizados obteve as maiores médias de resistência, porém sem diferenças significativas entre elas. / The purpose of this study was to evaluate the effect of provisional cements and dentin cleaning methods on the adhesion of resin bonded indirect restorations. Flat dentin surfaces were produced cutting extracted human molars. The teeth were divided randomly in seven experimental groups according with the provisional cement and the used dentin cleaning method: (G1- control) no provisional restoration and no dentin cleaning; (G2) pumice-water slurry cleaning after cementation with Life (Kerr); (G3) aluminum oxide sandblasting after cementation with Life; (G4) no cleaning procedure after Life cementation; (G5) pumice-water slurry cleaning after cementation with Temp Bond (Kerr); (G6) aluminum oxide sandblasting after cementation with Temp Bond and (G7) no cleaning procedure after Temp Bond cementation. After one week of storing in water, Solidex indirect restorations (Shofu) were cemented with Single Bond adhesive system (3M ESPE) and Rely X ARC cement (3M ESPE). All products were handled according with manufacturer’s instructions. The teeth were sectioned resulting in adhesion area of 1,0 mm2 specimens for microtencile tests. The resulted values were submitted to variance analysis and Tukey’s test. These values indicated the group which was contaminated with calcium hydroxide cement and had no dentin cleaning presented the lowest bond strength and was statistically different from the group with no contamination. Any of the used cements and cleaning methods got the highest means of bond strength, but with no relevant differences among them. With these results can be concluded that, after the treatment with provisional cements, the absence of dentin cleaning implies in lower bond strength values.
567

Aderência de revestimentos externos de argamassa em substratos de concreto : influência das condições de temperatura e ventilação na cura do chapisco / External mortar rendering bond in concrete substrates : influence of temperature and ventilation conditions during the slurry layer curing

Moura, Cristiane Borges January 2007 (has links)
A prevenção de manifestações patológicas em revestimentos de argamassa, em especial os descolamentos, é refletida no interesse das empresas construtoras e pesquisadores por um maior conhecimento das propriedades dos elementos constituintes do sistema, bem como dos fatores externos. Destes pode-se citar as variáveis que intervêm nos mecanismos de aderência, porém que não são controláveis, como a temperatura, umidade e ventilação. Neste contexto, o presente trabalho objetiva analisar a influência da ação do vento e da temperatura elevada durante a cura da argamassa de chapisco na aderência dos revestimentos externos de argamassa aplicados em substratos de concreto. Foram moldados prismas nas dimensões 40x45x10cm, com resistência aos 28 dias de 37MPa. Utilizou-se 3 argamassas de chapisco, uma dosada em obra com traço 1:5,67 (em massa com areia seca) e outras duas industrializadas de diferentes fabricantes. Também foram utilizadas 3 argamassas de revestimento, uma dosada em obra com traço 1:0,78:6,5 (em massa com areia seca), e outras duas industrializadas de diferentes fabricantes, sendo os mesmos das argamassas de chapisco. Combinou-se os tipos de argamassa de chapisco e revestimento juntamente com o modo de preparo de cada para a composição de diferentes sistemas de revestimento, num total de 90 combinações aplicadas em 45 prismas. Em todos eles, uma das faces recebia a ação do vento durante a cura de três dias da argamassa de chapisco e em 18 deles ambas as faces recebiam também a ação da temperatura de 40°C (os demais eram curados a 23°C). As argamassas de revestimento eram curadas durante 28 dias a uma temperatura de 23±2°C, sem a ação do vento. A umidade relativa do ar foi fixada em 60±5%. Foram realizados ensaios de resistência de aderência à tração do revestimento pela NBR 13528/95 e ensaios e de caracterização do concreto do substrato e das argamassas, estes últimos conforme prescrições da NBR 13281/05. Corpos-de-prova das argamassas de chapisco também foram curadas sob as mesmas condições a que os primas foram submetidas. As resistências médias de aderência obtidas variaram de 0,01 a 0,32MPa para chapiscos convencionais, 0,03 a 0,36MPa para os industrializados 1 e 0,06 a 0,33MPa para os industrizados 2. Com os dados obtidos fez-se análise estatística de variância (ANOVA). Os resultados demonstraram que a ação da ventilação e do calor influenciaram de forma significativa a resistência de aderência, sendo responsáveis por uma queda de 0,014MPa e 0,085MPa, respectivamente. Também se mostraram significativas as variáveis tipo de argamassa de chapisco e de revestimento. / The prevention of pathological manifestations in mortar renderings, in special case the detachment, reflected a concern of researches and construction companies aiming the knowledge of materials and rendering systems properties, as well as any other external factors. In this case, some variables that intervene (however not-controllable) in the bond strength mechanisms can be cited, as the temperature, humidity and ventilation. In this context, this work objective to analyze the influence of wind and high temperature during the slurry mortar cure and this relationship with the bond of external mortar renderings in concrete substrates. Concrete prisms of 40x45x10cm had been molded, with strength at 28 days of 37MPa. Three mixes of slurry mortars had been used, one proportioned in situ with a cement/aggregate proportion of 1:5,67(in mass) and two other different pre-mixed slurry mortars. Also three mixes of rendering mortars had been used, one proportioned in situ with a cement/limestone/aggregate proportion of 1:0,78: 6,5 (in mass), and two other different premixed mortars. A total of 45 prisms with 90 combinations (with the different slurry and rendering mortars, as well as different sample preparations) had been produced. For each prism, one of the rendered faces had been assayed simulating the wind action during the three days cure of the slurry mortar and in 18 from both them the faces covered also had been assayed with the action of 40ºC temperature (the others were cured at 23°C). Rendering mortars were cured at 23±2°C during 28 days, without wind influence. The humidity was fixed in 60±5%. The mortars (according NBR 13281/05) and concrete substrata characterization, as well as assays of tensile bond strength of the rendering (according NBR 13528/95) had been carried through. Samples of slurry mortars were also cured over the same conditions the prisms were submited. All data obtained had been statistically analyzed trough variance analysis (ANOVA). The results had demonstrated that the wind effect and the heat condition had influenced significantly the bond strength. The type of slurry or rendering mortar had also revealed significant effect in the bond strength.
568

Efeito da incorporação de agentes antifúngicos na resistência à tração e porosidade de materiais resilientes temporários para base de próteses / Effect of incorporation of antifungal agents on the ultimate tensile strength and porosity of temporary soft denture liners

Jozely Francisca Mello Lima 10 February 2017 (has links)
Este estudo investigou a resistência à tração (ou limite de resistência à tração- LRT) e a porosidade de reembasadores resilientes temporários modificados por concentrações inibitórias mínimas (CIMs) de agentes antifúngicos para o biofilme Candida albicans (SC5314). Para os testes de LRT, corpos de prova em forma de halteres (n=7) com uma área transversal de 33 mm x 6 mm x 3 mm foram produzidos para os materiais resilientes (Trusoft e Softone) sem (controle) ou com incorporação de cinco fármacos em suas CIMs: nistatina- 0,032 g; diacetato de clorexidina- 0,064; cetoconazol- 0,128 g; miconazol- 0,256 g; itraconazol-0,256 g (grama de fármaco por grama de pó de material resiliente). Após a plastificação, as amostras foram imersas em água destilada a 37°C durante 24 h, 7 e 14 dias e, então, testadas em tensão em uma máquina universal de ensaios (EMIC DL-500 MF) a 40 mm/min. A porosidade foi mensurada por absorção de água, com base na exclusão do efeito plastificante. Inicialmente, determinou-se por isotermas de sorção, que a solução de armazenagem adequada para os corpos de prova (65 mm x 10 mm x 3,3 mm) de ambos os materiais foi o cloreto de cálcio anidro a 50% (S50). Assim, o fator de porosidade (FP) foi calculado para os grupos de estudo (n=10) formados por espécimes sem (controle) ou com incorporação de fármaco em suas CIMs (nistatina, clorexidina ou cetoconazol) após a armazenagem em água destilada ou S50 por 24 h, 7 e 14 dias. Os dados de resistência à tração (MPa) e percentagem de alongamento (%) foram submetidos à ANOVA de 3 fatores seguida pelo teste de Tukey (=0,05). Os dados de porosidade foram analisados estatisticamente por ANOVA de medidas repetidas para 4 fatores e teste de Tukey (=0,05). Ao final de 14 dias, a resistência à tração para ambos os materiais foi significativamente menor nos grupos modificados pelo miconazol e itraconazol em relação aos outros grupos (P<0,0001), que não mostraram diferenças significativas entre si (P>0,05). Após 7 e 14 dias em água, o miconazol e itraconazol adicionados a ambos os materiais resultaram em percentagens significativamente menores de alongamento em comparação com os outros fármacos e ao controle (P<0,0001), que foram semelhantes entre si (P>0,05). O cetoconazol não resultou em alterações significativas no FP para ambos os materiais resilientes em água ao longo de 14 dias (P>0,05). Em comparação aos controles, houve aumento dos FPs do Softone e Trusoft aos 14 dias de imersão em água somente após a adição de nistatina e clorexidina e de clorexidina, respectivamente (P<0,05). Ambos os materiais não apresentaram alterações significativas no FP em até 14 dias de imersão na S50, em comparação aos controles (P>0,05). Em todas as condições experimentais, os FPs do Softone e Trusoft foram significativamente menores quando imersos em S50 em comparação com a água destilada (P<0,05). Concluiu-se que a adição de nistatina, clorexidina e cetoconazol nas CIMs para o biofilme de C. albicans não resultou em efeitos deletérios na resistência à tração e na percentagem de alongamento dos materiais resilientes temporários para base de prótese até o período de 14 dias. A adição de antifúngicos nas CIMs não resultou em efeitos adversos à porosidade de ambos os materiais resilientes temporários em diferentes períodos de imersão em água, com exceção da clorexidina e nistatina no Softone e clorexidina no Trusoft aos 14 dias. Não foram observados efeitos deletérios para a porosidade de ambos os materiais resilientes modificados com as CIMs dos fármacos durante os 14 dias de imersão na S50. / This study investigated the tensile strength (ultimate tensile strength- UTS) and porosity of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314). For UTS tests, dumbbell-shaped specimens (n=7) with a central cross-sectional area of 33 mm x 6 mm x 3 mm were produced by resilient materials (Trusoft and Softone) without (control) or with incorporation of five drugs at MICs: nystatin- 0.032 g; chlorhexidine diacetate-0.064 g; ketoconazole- 0.128 g; miconazole- 0.256 g; itraconazole- 0.256 g (each per gram of soft liner powder). After plasticization, specimens were immersed in distilled water at 37°C for 24 h, 7 and 14 days, and then tested in tension in a universal testing machine (EMIC DL-500 MF) at 40 mm/min. The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65 mm x 10 mm x 3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin, chlorhexidine or ketoconazole) after storage in distilled water or S50 for 24 h, 7 and 14 days. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA followed by Tukey\'s test (=0.05). Data of porosity were statistically analyzed by 4-way repeated measures ANOVA and Tukeys test (=0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (P<0.0001), which showed no significant difference between them (P>0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials result in significant lower elongation percentages compared to the other drugs and control (P<.0001), which were similar to each other (P>0.05). Ketoconazole resulted in no significant changes in PF for both liners in water over 14 days (P>0.05). Compared to the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of nystatin and chlorhexidine, and chlorhexidine, respectively (P<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared to the controls (P>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared to distilled water (P<0.05). It was concluded that the addition of the nystatin, chlorhexidine and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the ultimate tensile strength and elongation percentage of the temporary soft denture liners up to 14-day period. The addition of antifungals at MICs resulted in no detrimental effects for the porosity of both temporary soft liners in different periods of water immersion, except for chlorhexidine and nystatin in Softone and chlorhexidine in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion.
569

Avaliação ex vivo da resistência à tração, de pinos metálicos em raízes fragilizadas tratadas com laser Er:YAG e reforçadas com resina composta / Tensile bond strength of metal posts after the application of Er:YAG laser treatment to the weakened root canal reinforced with composite resin

Luciana Cavali Santello 07 February 2012 (has links)
O objetivo do estudo foi avaliar ex vivo a influência da aplicação do laser de Er:YAG na parede dentinária de raízes fragilizadas, reforçadas com resina composta. Cinquenta caninos superiores tiveram suas coroas removidas próximo da junção amelo-cementária e incluídas em bloco de resina acrílica. Após tratamento endodôntico foi realizada a fragilização das raízes. Os espécimes foram distribuídos aleatoriamente em 5 grupos (n=10),: Grupo I - não irradiado, tratado com ácido fosfórico 37%; Grupo II - irradiado com laser Er:YAG, 300mJ - 10 Hz; Grupo III - irradiado com laser Er:YAG, 300mJ - 10 Hz e tratado com ácido fosfórico 37% ;Grupo IV - irradiado com laser Er:YAG, 500mJ - 10 Hz; Grupo V - irradiado com laser Er:YAG, 500mJ - 10 Hz e tratado com ácido fosfórico 37%. Todos os espécimes receberem reforço intra-radicular com resina composta, foto-polimerizada por meio de pino foto-transmissor. No espaço promovido por este pino foi cimentado o pino metálico pré-fabricado, com cimento resinoso auto-adesivo de dupla polimerização. Os espécimes foram submetidos ao teste de Tração na Máquina Universal de Ensaios - INSTRON 4444. Os maiores valores para o deslocamento foram atribuídos ao Grupo I, estatisticamente semelhante ao Grupo III. Entretanto o Grupo III ocupa uma posição intermediária, podendo pertencer também aos GruposIV e V que foram estatisticamente semelhantes entre si e ao grupo II. / The aim of this study was to assess ex vivo the effects of Er:YAG laser as dentin treatment of weakened root canal reinforced with composite resin. Fifty upper canines were decoronated at cementoenamel junction and the roots were embedded in acrylic resin. After the endodontic treatment the roots were weakened and the specimens were randomly assigned to five groups (n=10): Group I - unirradiated, treated with phosphoric acid 37%; Group II - Er:YAG laser 300mJ - 10Hz; Group III - Er:YAG laser 300mJ - 10 Hz, treated with phosphoric acid 37%; Group IV - Er:YAG laser 500mJ - 10 Hz; Group V - Er:YAG laser 500mJ - 10 Hz, treated with phosphoric acid 37%. The intraradicular reinforcement was made in all specimens with composite resin using photo-transmitter post, which creates a space for the insertion of prefabricated metal post. The metal posts were inserted using a resin cement self-adhesive dual-cured. The tensile bond strength of specimens was tested in a universal testing machine - INSTRON 4444. The results showed that Group I was statistically similar to the Group III and presented the highest bond strength values. Group III also showed statistical similarity with Group IV and V, which were similar among them and the Group II.
570

Influência do substrato, dentes decíduos e permanentes, e da aplicação de clorexidina na resistência de união de sistemas adesivos à dentina

Ricci, Hérica Adad [UNESP] 31 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-31Bitstream added on 2014-06-13T20:56:55Z : No. of bitstreams: 1 ricci_ha_me_arafo.pdf: 5754371 bytes, checksum: 74988ba41e6d82c0fe9ae7a66dd7310d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Proposição: O objetivo deste trabalho, dividido em três estudos, foi (1) investigar o efeito do substrato, dentina de dentes decíduos e permanentes, assim como (2) o efeito imediato e (3) em longo prazo, da aplicação de clorexidina pós-condicionamento ácido da dentina na resistência de união (RU) de sistemas adesivos. Materiais e Métodos: Nos estudos 1 e 2, realizados in vitro, foram utilizados molares decíduos e pré-molares, divididos em três grupos segundo a aplicação dos sistemas adesivos Prime & Bond NT, Adper Single Bond e Excite DSC. Sobre superfícies planas em dentina, foi realizado o condicionamento com ácido fosfórico a 35% por 15 s, o qual foi removido com lavagem abundante. Após remoção do excesso de umidade, os sistemas adesivos foram aplicados segundo a recomendação dos fabricantes. Apenas para o estudo 2, em 50% dos dentes para cada sistema adesivo foram aplicados 20 μL de clorexidina a 2% por 60 s sobre a dentina condicionada. Seguida à aplicação dos sistemas adesivos, as coroas foram reconstruídas em resina composta. Para o estudo 3, foram selecionados 13 voluntários que apresentavam no mínimo 2 molares decíduos contralaterais com lesão de cárie oclusal, sendo os dentes aleatoriamente designados aos grupos controle ou experimental. Após o preparo cavitário, no grupo controle, 5 μL de água destilada foram aplicados sobre a dentina condicionada com ácido fosfórico, enquanto no grupo experimental foi aplicado o mesmo volume de solução de clorexidina 2%. Os dentes foram restaurados com Prime&Bond NT e resina Z250 e recuperados quando da esfoliação, definindo os períodos de função na cavidade bucal como até 30 dias, de 1 a 5, de 10 a 12 e de 18 a 20 meses. Para todos os experimentos, os dentes foram cortados em espécimes com área transversal aproximada de 0,81mm² para realização do ensaio mecânico de microtração... / Purpose: The aim of this work, divided in three studies, was to investigate (1) the effect of the substrate, dentin of primary and permanent teeth, as well as, (2) the effect of chlorhexidine application after acid etching on the immediate and (3) long-term bond strength of adhesive systems to dentin. Materials and Methods: In studies 1 and 2, performed in vitro, primary molars and pre-molars were assigned to three groups according to the adhesive systems Prime & Bond NT, Adper Single Bond and Excite DSC. Flat dentin surfaces were etched with 35% phosphoric acid for 15 s, followed by abundant water rinse. After the removal of the excess of water, the adhesive systems were applied following the manufacturer´s instructions. Only in study 2, fifty percent of the teeth for each adhesive system received the application of 2% chlorhexidine for 60 s after acid etching. Following the application of the adhesive systems, the crowns were rebuilt in composite resin. In study 3, thirteen volunteers were included which had at least one pair of primary contralateral molars with occlusal caries lesions. The teeth were randomly assigned into the control or experimental group. After the class I cavity preparation, for the control group, five microliters of distilled water were applied on the phosphoric acid etched dentin, while for the experimental group the same volume of 2% chlorhexidine was used. The cavities were restored with Prime&Bond NT and Z250 resin and the teeth were retrieved after exfoliation defining the periods of function in the oral cavity as up to 30 days, 1-5, 10-12 and 18-20 months. In all studies, the teeth were cut to produce beams with 0.81 mm² cross-sectional area, which were subjected to the microtensile test. Bond strength (μTBS) data were submitted to ANOVA and Tukey statistical tests (α=0.05). Results: There was no statistically significant difference for μTBS values...(Complete abstract click electronic access below)

Page generated in 0.3462 seconds