• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 188
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 1
  • 1
  • Tagged with
  • 201
  • 115
  • 47
  • 35
  • 31
  • 21
  • 21
  • 19
  • 17
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Parâmetros para o desenvolvimento de sapatilhas femininas de uso diário com ênfase no conforto térmico e percepção da usuária / Parameters for the Development of Daily Use Women Sneakers with emphasis in the Thermal Comfort and Wearer s Perception

Anselmo, Taiza Kalinowski 31 July 2014 (has links)
Made available in DSpace on 2016-12-12T20:17:55Z (GMT). No. of bitstreams: 1 118616.pdf: 3322963 bytes, checksum: 8c90d7f36cbfba744957ccedd7c6749a (MD5) Previous issue date: 2014-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Research related to the thermal comfort in shoes has been bringing substantial technological advancements to the shoe sector. The present study aims to contribute the evaluation of the thermal comfort attribute of materials used in shoe manufacturing. During this development, qualitative and quantitative techniques were applied which contributed to the evaluation of the materials studied. Two volunteers participated in the present study where they tested five similar sneakers, manufactured with different types of lining materials being laminated synthetic polyurethane with viscose substrate, polyester, viscose and polyester mix, cacharrel and leather. Evaluated points: a) volunteers perception of heat and humidity thermal evaluation and easiness of wearing in a 1 to 10 scale; b) their perception in regards to the areas which present higher variation in thermal comfort; c) feet temperature variation from thermopairs readings (Digital Thermometer TD 890 with 4 channels); d) feet thermal radiation variation using thermographic camera (Eletrophysics PV 320 model). The measurement procedures were taken during a 30 min walk at 4km/h speed. The perception, the temperature and radiation evaluation were measured before and after the 30 min. walk. The qualitative research has appointed leather as the best performance material throughout the tests. The region, which presented the highest perception in heating and humidity increase perception, was the toes region. The highest increase in temperature occurred in the Viscose lined sneaker, with a general mean percentage of 13.16% for the thermo-pairs and of 14.03% for the thermographics. Leather had the best performance with a mean percentage of approximately 1%. Despite this difference, none of the materials was considered uncomfortable according to the ABNT/NBR 14837 table of the Level of Internal Shoe Temperature Comfort. All the materials used was considered comfortable with the exception of Viscose, which was considered normal/acceptable according to the table. / A pesquisa do conforto em calçados vem proporcionando avanços tecnológicos significativos para o setor calçadista. Este estudo procurou contribuir com a avaliação de materiais usados na confecção de calçados, que promovam conforto térmico. Ao longo do desenvolvimento, foram aplicadas técnicas qualitativas e quantitativas que contribuíram na avaliação destes materiais. Participaram do estudo duas voluntárias, que testaram cinco pares de sapatilhas similares, confeccionadas com diferentes materiais no forro, laminado sintético de poliuretano com substrato em viscose, poliéster, misto (viscose e poliéster), o cacharrel e o couro. Foram avaliados: a) a percepção das voluntárias quanto à avaliação térmica de aquecimento e umidade, e calce através de uma escala com pontuação de 1 a 10; b) a percepção das regiões que apresentaram maior alteração do conforto térmico; c) registro da variação de temperatura dos pés a partir de medidas com termopares (Termômetro Digital TD 890 com 4 canais); d) registro da variação da radiação térmica do pé utilizando câmera termográfica (Eletrophysics modelo PV 320). Os procedimentos de medidas, foram conduzidos ao longo de uma caminhada de 30 min a 4 km/h. A avaliação da percepção, temperatura e radiação foram medidas antes e depois da caminhada. A pesquisa qualitativa apontou, o couro como o material que apresentou maior desempenho ao longo dos testes. A região dos pés com maior percepção de aquecimento e umidade foram os dedos. O incremento de temperatura ocorreu principalmente na sapatilha com forro viscose, com uma média percentual geral de 13,16% para os termopares e 14,03% para a termografia. O couro teve o maior desempenho, com uma média percentual aproximadamente 1%. Apesar desta diferença, nenhum material foi considerado desconfortável, de acordo com a tabela do Nível de conforto da temperatura interna do calçado ABNT/NBR 14837. Todos os materiais foram considerados confortáveis, com exceção da viscose considerada de acordo com a tabela normal.
172

Método de avaliação de conforto térmico em órteses esportivas de joelho / Thermal Comfort Evaluation Method in Sports Knee Orthosis

Porto, Maetê da Costa 28 November 2014 (has links)
Made available in DSpace on 2016-12-12T20:17:56Z (GMT). No. of bitstreams: 1 120540.pdf: 27415901 bytes, checksum: e03c3666fff42b314d4f3ee99e734fb3 (MD5) Previous issue date: 2014-11-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The present study aims to evaluate the temporal evolution of the temperature and humidity provided by different materials used in the lining of sports orthotics neoprene knee with the interface. This is a study of exploratory and descriptive and experimental nature, combined with quantitative and qualitative data collection methods and analysis of thermographic images approach. Measurements occurred in six alternate days in the morning. Identical orthoses made with smooth, neoprene lined on the outside with black polyamide fabric, with different liners (100 % polyester, 100 % polyamide, Emana® 270g, double frontura, Emana® 350g) and identical orthoses made from perforated neoprene lined were evaluated on the outside with black polyamide fabric and various lining (100 % polyester, 100 % polyamide, Emana® 270g, double frontura, Emana® 350g). Volunteers (men) were selected according to age, sex, BMI, duration of practice, hours of weekly practice, to have a physical integrity. For the tests used the same garments clo value. The instruments used were: a thermographic camera Eletrophysics model PV 320 and a precision scale BEL Engenering - Mark 160 - Class II. Temperature data were analyzed by thermography knees and moisture with the mass difference of bracing before and after the test. Of the materials tested, the combination of double polyester lining, perforated neoprene and nylon on the outside of the orthosis showed the best performance in knee - brace interaction. / O presente estudo tem por objetivo desenvolver um método para avaliar a evolução temporal da temperatura e umidade proporcionado por diferentes materiais utilizados no forro das órteses esportivas de neoprene com a interface do joelho. Trata-se de um estudo de cunho exploratório-descritivo e experimental, com abordagem combinada de métodos quantitativos e qualitativos de coleta e análise de imagens termográficas. As medições ocorreram em seis dias alternados no período da manhã. Foram avaliadas órteses idênticas confeccionadas com neoprene liso, forrado na parte externa com tecido poliamida preto, com diferentes forros: 100% poliéster, 100% poliamida, Emana® 270g, dupla frontura e Emana® 350g. Órteses idênticas confeccionadas com neoprene perfurado, também foram avaliadas, forradas na parte externa com tecido poliamida preto e diferentes forros:100% poliéster, 100% poliamida, Emana® 270g, dupla frontura e Emana® 350g. Os voluntários (homens) foram selecionados segundo a idade, sexo, IMC, tempo de prática, horas de treinos semanais, para ter uma integridade física. Para os testes utilizaram vestimentas com o mesmo valor em clo que é a unidade utilizada para medir o isolamento térmico das roupas. Os instrumentos de medida utilizados foram: uma Câmera Termografica Eletrophysics modelo PV 320 e uma balança de precisão BEL Engenering - Mark 160 - Classe ll. Foram analisados dados de temperatura através da termografia dos joelhos e a umidade com a diferença de massa da órtese antes e depois do ensaio. Dos materiais testados, a combinação forro de duplo poliéster, neoprene perfurado e a poliamida na parte externa da órtese apresentou o melhor desempenho na interação joelho-órtese.
173

Análise e extração de características de imagens termográficas utilizando componentes principais /

Santos, Gilnete Leite dos. January 2010 (has links)
Orientador: João Antonio Pereira / Banca: Amarildo Tabone Paschoalini / Banca: Renê Pegoraro / Resumo: As técnicas de termografia vêm atualmente ganhando espaço como técnicas de manutenção preditiva, principalmente, por seu caráter não invasivo (ferramenta de não contato) que possibilita o monitoramento do aquecimento de máquinas e equipamentos em operação ou mesmo energizados. A utilização de câmeras termográficas hoje é uma realidade em vários setores industriais para monitoramento e detecção de falhas com base na temperatura. Entretanto, a utilização de câmaras termográficas na manutenção não deve se restringir apenas à avaliação da temperatura, uma vez que as imagens termográficas são sinais que apresentam padrões complexos que podem captar as diferentes características e condição de operação do equipamento. Outras informações além da temperatura poderiam ser observadas para uma avaliação mais consistente do estado de operação do equipamento. Este trabalho discute a utilização da técnica da estatística multivariada, Análise de Componentes Principais (ACP) para o processamento e análise de um conjunto de imagens termográficas. Essa proposta visa à identificação de padrões associados às variações térmicas das imagens, bem como, a interpretação desses dados em termos da sua variabilidade espacial/temporal para aplicação na manutenção preditiva com base na termografia. Num primeiro momento a técnica foi aplicada para a avaliação de um conjunto de dados (imagens térmicas) obtidos a partir da simulação do aquecimento de um dado componente (chave elétrica), cujo objetivo foi testar e verificar a validade da proposta e do programa desenvolvido. Posteriormente a técnica foi aplicada para o acompanhamento e avaliação do aquecimento de componentes de um modelo simplificado de um painel de telefonia, formado por blocos de alumínio fixados em uma placa de acrílico. A análise no modo espacial e no modo temporal do conjunto de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Thermography techniques are currently gaining ground as predictive maintenance techniques, mainly due to its non-invasive character (non-contact tool) that allows the monitoring of heating condition of machines and equipment also in operation and even energized. The use of thermographic cameras is now a reality in many industrial and electrical sectors for monitoring and fault detection based on temperature. However, the use of thermal imagers in the maintenance should not be restricted to only the evaluation of temperature, since the thermographic images are signs that show complex patterns and they can capture the different characteristics of the actual condition of the monitored equipment. Information other than temperature could be observed for a more consistent evaluation of its state of operation. This paper discusses the propose of use of the multivariate analysis technique, Principal Component Analysis (PCA) for the processing and analysis of a series of thermographic images in order to identify patterns associated with temperature variations of the images, as well as, the interpretation of these data in terms of their spatial/temporal variability. Initially the technique was used to the analysis of data (thermal images) obtained from the simulation of heating conditions of a component (electric switch) aiming at to test and verify the validity of the proposal and program development. Later the technique was applied to the monitoring and evaluation of the heating condition of components of a simplified model of a telephone panel, formed by aluminum blocks fixed in a plate of acrylic. The analysis in the spatial and temporal mode of the set of thermograms obtained for different heating conditions of the blocks, it showed that it is possible to verify and establish correlations between the Principal Components and the thermal profile of the system / Mestre
174

Farelo de girassol na alimentação de aves Isa Label em fase de postura em ambiente equatorial / Sunflower meal for feeding of Isa Label laying hens in an equatorial environment

Oliveira, Vanessa Raquel de Morais 28 February 2014 (has links)
Made available in DSpace on 2016-08-15T20:31:23Z (GMT). No. of bitstreams: 1 VanessaRMO_DISSERT.pdf: 1127022 bytes, checksum: 07a116e7740f17e848fd3a76785ea47b (MD5) Previous issue date: 2014-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / ABSTRACT - The objective of this study was to evaluate production and egg quality of laying hens Isa Label fed different levels of sunflower meal, the infrared thermography and productive characteristics of laying hens in semi-intensive production system in tropical conditions. One hundred and twenty-eight laying hens with early age of 28 weeks, during 16 weeks of evaluation, distributed in a completely randomized design in 16 boxes with 8 birds per experimental unit were used. The treatments consisted in a control diet (RCO) and three diets containing sunflower meal in substitution for soybean meal, based on the crude protein levels of 10, 20 and 30% (FG10, FG20, FG30) , being all diets based on the nutritional requirements of the laying hens. During the total period of review there was no difference (p> 0.05) between the levels of substitution of crude protein of soybean meal by sunflower meal on productive performance and egg quality of laying hens. The economic analysis of dietary treatments decreased the price per kilogram of feed (1.49, 1.46, 1.44, 1.41 reais, respectively) as replaced by 0, 10, 20 and 30% levels crude protein soybean meal by sunflower meal. The FG30 treatment compared with other treatments was better, it showed better Average Cost Index (ACI) and Economic Efficiency Index (EEI). The egg production was not influenced with the temperature increase over the weeks, obtaining higher production values between the 39th and 42nd weeks of age, which is due to genetic effects of Isa label. In the evaluation of the surface temperature by infrared thermography, laying hens showed higher average temperature in the neck region (39.35° C), followed by face (38.47° C), feet (37.15° C) and feathered area (31.56° C). Therefore, taking into consideration the viability was observed, the replacement of soybean meal by sunflower meal in balanced diets for broilers Isa label in laying phase can be used / Objetivou-se com este estudo avaliar produção e qualidade dos ovos de poedeiras da linhagem Isa Label alimentadas com diferentes níveis de farelo de girassol, termografia infravermelha e características produtivas de aves em sistema de produção semi-intensivo em condições tropicais. Foram utilizadas 128 aves poedeiras com idade inicial de 28 semanas, durante 16 semanas de avaliação, distribuídas em delineamento inteiramente casualizado, em 16 boxes, com 8 aves por unidade experimental. Os tratamentos constituíram-se em uma ração controle (RCO) e três rações contendo farelo de girassol em substituição ao farelo de soja, com base no teor de proteína bruta, nos níveis de 10, 20 e 30 % (FG10, FG20, FG30), sendo todas as rações formuladas com base nas exigências nutricionais das aves. Durante o período total de avaliação não observou-se diferença (p>0,05) entre os níveis de substituição da proteína bruta do farelo de soja pelo farelo de girassol para o desempenho produtivo e qualidade de ovos das aves. A análise econômica dos tratamentos dietéticos apresentou redução no preço por quilograma de ração (1,49, 1,46, 1,44, 1,41 reais, respectivamente) à medida que substituiu em 0, 10, 20 30% os níveis de proteína bruta do farelo de soja pelo farelo de girassol. O tratamento FG30 em comparação com os demais tratamentos foi melhor, pois apresentou melhor Índice de Custo Médio (ICM) e Índice de Eficiência Econômica (IEE). A produção de ovos não teve influencia do aumento da temperatura ao longo das semanas, obtendo maiores valores de produção entre a 39ª e 42ª semanas de idade o que se deve ao efeito genético da linhagem Isa label. Na avaliação da temperatura superficial das aves através da termografia infravermelha a maior média foi encontrada no pescoço (39,35 °C) seguida da face (38,47 °C) e patas (37,15 °C), onde a área com penas apresentou a menor média (31,56 °C) entre as regiões estudadas. Portanto, levando em consideração a viabilidade econômica das rações, a substituição do farelo de soja pelo farelo de girassol em rações balanceadas para aves Isa label em fase de postura podem ser utilizadas
175

Estudo termográfico de auxílio à detecção de falhas por desgaste mecânico em rolamento autocompensador de esferas. / Thermographic study for detection of faults by mechanical wear in self-aligning bearings.

CABRAL, Adriano de Sousa. 20 August 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-08-20T12:32:16Z No. of bitstreams: 1 ADRIANO DE SOUSA CABRAL - DISSERTAÇÃO (PPGEM) 2017.pdf: 4297640 bytes, checksum: 947cc1f3c800182da45417aaab2b3861 (MD5) / Made available in DSpace on 2018-08-20T12:32:16Z (GMT). No. of bitstreams: 1 ADRIANO DE SOUSA CABRAL - DISSERTAÇÃO (PPGEM) 2017.pdf: 4297640 bytes, checksum: 947cc1f3c800182da45417aaab2b3861 (MD5) Previous issue date: 2017-07-26 / O objetivo desta pesquisa foi analisar se a Termografia pode auxiliar na detecção de falhas em elementos de máquinas, notadamente rolamentos autocompensadores com 2 carreiras de esferas. A motivação surgiu da necessidade de verificar os pontos de falhas existentes nestes elementos mecânicos visando minimizar e/ou eliminar paradas inesperadas que possam comprometer o bom funcionamento dos mesmos e consequentemente das máquinas às quais estão inseridos. A pesquisa é classificada como investigativa, documental, prescritiva, qualitativa e quantitativa. A metodologia utilizada fez uso de bancada de testes composta por elementos mecânicos diversos a citar: motor elétrico controlado por inversor de frequência, amortecedores de vibração (vibra-stop), polias e correias, mancais de rolamentos, carga em eixo, câmera térmica e rolamentos autocompensadores modificados com defeitos nas pistas interna e externa em cenário com condições de controle e não-controle de temperatura ambiente, umidade relativa, rotação do motor, velocidade do ar, temperatura refletida e emissividade. Como resultado, observou-se que houve alteração significativa de temperatura nas pistas interna e externa dos rolamentos com falha do tipo sulco. Por outro lado, não foram percebidas alterações significativas nas pistas interna e externa do rolamento com falha por desgaste por abrasão. Por fim, conclui-se, neste trabalho, que a hipótese inicial foi parcialmente confirmada, isto é, a Termografia pode sim auxiliar a detectar as falhas mecânicas, mas falhas do tipo sulco e não as falhas do tipo desgaste abrasivo. / The aim of this study was to verify if Thermography can help in the diagnosis of failures in machine elements, notably self-aligning bearings with 2 rows of balls. The motivation arose from the need to verify the fault points existing in these mechanical elements to minimize and / or eliminate unexpected stops that could compromise the proper functioning of themselves and consequently of the machines of which they are part of. This study is classified as investigative, documentary, prescriptive, qualitative and quantitative. The methodology made use of test bench composed of several mechanical elements: electric motor controlled by frequency inverter, vibration-stop buffers, pulleys and belts, house bearings, radial load, thermal camera and self-aligning bearings with inner and outer race fault in a scenario with control conditions and non-control of ambient temperature, relative humidity, engine speed, air velocity, reflected temperature and emissivity. It was confirmed that there was a significant temperature change in the inner and outer races of groove-type failure bearings. On the other hand, no significant changes were observed in the inner and outer races of the bearing with abrasion wear failure. Finally, it was concluded in this work that the initial hypothesis was partially confirmed, that is, the Thermography can help to detect mechanical failures in groove type failures but not abrasive wear type failures.
176

Variáveis nutricionais e fisiológicas de ovinos da raça Morada Nova de diferentes classes sexuais submetidos à restrição alimentar / Nutritional and physiological measurements of Morada Nova sheep breed of different sexual classes subjected to feed restriction

Heinzen, Eduardo Luiz January 2016 (has links)
HEINZEN, Eduardo Luiz. Variáveis nutricionais e fisiológicas de ovinos da raça Morada Nova de diferentes classes sexuais submetidos à restrição alimentar. 2016. 50 f. : Dissertação (Mestrado) - Universidade Federal do Ceará, Centro de Ciências, Departamento de Zootecnia, Programa de Pós-Graduação em Zootecnia. Fortaleza-CE, 2016. / Submitted by Eric Santiago (erichhcl@gmail.com) on 2016-08-03T13:37:27Z No. of bitstreams: 1 2016_dis_elheinzen.pdf: 1285825 bytes, checksum: 32955795d549452fb81768336e0dfffc (MD5) / Approved for entry into archive by Nádja Goes (nmoraissoares@gmail.com) on 2016-08-03T13:51:24Z (GMT) No. of bitstreams: 1 2016_dis_elheinzen.pdf: 1285825 bytes, checksum: 32955795d549452fb81768336e0dfffc (MD5) / Made available in DSpace on 2016-08-03T13:51:24Z (GMT). No. of bitstreams: 1 2016_dis_elheinzen.pdf: 1285825 bytes, checksum: 32955795d549452fb81768336e0dfffc (MD5) Previous issue date: 2016 / This study was accomplished with the objective of determining the effects of sexual class and feed restriction on nutrient intake, digestibility, purine derivatives, nitrogen balance, feeding behavior and physiological parameters in hair sheep Morada Nova. Thirty-five animals (11 intact males, 12 castrated and 12 females) with an initial average weight of 14.5 ± 0,89kg were used in a completely randomized design in a 3x3 factorial design with three sexual classes (intact males, castrated and females) and three levels of feed restriction (ad libitum, 30 and 60%). Sexual class and feed restriction influenced (P<0.05) the intake of dry matter (DM), organic matter (OM), crude protein (CP), ether extract (EE), neutral detergent fiber corrected for ash and protein (NDFap), total carbohydrates (TC), non-fibrous carbohydrates (NFC), total digestible nutrients (TDN) and metabolied energy (ME) and the balance of nitrogen compounds. The digestibility coefficient of DM, CP and EE were influenced (P<0.05) by feed restriction, however there was no effect (P>0.05) the sexual class on the digestibility coefficients of CP, EE and NFC. There was interaction between sexual class and feed restriction (P<0.05) in digestibility of OM, NDFap and CT. Eating times (ET) and rumination times (RUT) were affected by feed restriction (P<0.05), however they were not affected by sexual class (P>0.05). The urinary volume, excretions of creatinine, allantoin, xanthine and hypoxanthine, absorption of purine derivatives (absPD), total purine derivatives (PD) and microbial protein synthesis (micCP) were not influenced (P>0.05) by sexual class. Urine output, creatinine excretion, xanthine and hypoxanthine were not influenced by feed restriction (P>0.05), however, this factor influenced the excretion of allantoin, uric acid, absPD and PD. Physiological parameters, surficial temperature (ST) on the left of pectoral region and rectal temperature (RT), were not affected by sexual class (P>0.05). Feed restriction and the period of collect of physiological variables influenced (P<0.05) ST the left side, chest and RT. There was interaction (P<0.05) between sexual class and feed restriction ST to the right side. Intake and digestibility of nutrients are influenced by more severe dietary restrictions. Sexual class does not influence the excretion of purine derivatives and microbial protein synthesis. Feed restriction reduces heat losses by body surface of lambs. / Este estudo foi realizado com o objetivo de determinar os efeitos da classe sexual e restrição alimentar sobre o consumo de nutrientes, digestibilidade, derivados de purina, balanço de nitrogênio, comportamento ingestivo e parâmetros fisiológicos de cordeiros da raça Morada Nova. Trinta e cinco animais (11 machos inteiros, 12 castrados e 12 fêmeas), com peso médio inicial de 14,5 ± 0,89kg, foram usados em delineamento inteiramente casualizado, em esquema fatorial 3x3, sendo três classes sexuais (machos inteiros, castrados e fêmeas) e três níveis de restrição alimentar (ad libitum, 30 e 60%). A classe sexual e a restrição alimentar influenciaram (P<0,05) o consumo de matéria seca (MS), matéria orgânica (MO), proteína bruta (PB), extrato etéreo (EE), fibra em detergente neutro corrigida para cinzas e proteína (FDNcp), carboidratos totais (CT), carboidratos não fibrosos (CNF), nutrientes digestíveis totais (NDT) e de energia metabolizável (EM) e o balanço dos compostos nitrogenados. O coeficiente de digestibilidade da MS, PB e EE foram influenciados (P<0,05) pela restrição alimentar, no entanto, não houve efeito (P>0,05) da classe sexual sobre os coeficientes de digestibilidade da PB, EE e CNF. Houve interação entre a classe sexual e a restrição alimentar (P<0,05) na digestibilidade da MO, FDNcp e CT. Os tempos de alimentação (TAL) e ruminação (TRU) foram influenciados pela restrição alimentar (P<0,05), no entanto, não foram influenciados pela classe sexual (P>0,05). O volume urinário, excreções de creatinina, alantoína, xantina e hipoxantina, absorção de derivados de purina (absDP), derivados de purinas totais (DP) e síntese de proteína microbiana (PBmic) não foram influenciados (P>0,05) pela classe sexual. Volume urinário, excreções de creatinina, xantina e hipoxantina não foram influenciados pela restrição alimentar (P>0,05), no entanto, este fator influenciou as excreções de alantoína, ácido úrico, absDP e DP. Os parâmetros fisiológicos temperatura superficial (TS) do lado esquerdo, região peitoral e temperatura retal (TR) não foram influenciados pela classe sexual (P>0,05). A restrição alimentar e o período de coleta das variáveis fisiológicas influenciaram (P<0,05) a TS do lado esquerdo, peito e TR. Houve interação (P<0,05) entre classe sexual e restrição alimentar para TS do lado direito. Consumo e digestibilidade de nutrientes são influenciados por restrições alimentares mais severas. Classe sexual não influencia a excreção de derivados de purina e síntese de proteína microbiana. A restrição alimentar diminui as perdas de calor pela superfície corporal de cordeiros.
177

Termografia computadorizada na identificação de trigger points miofasciais / Identification of myofascial trigger points by computerized thermography

Balbinot, Luciane Fachin 24 November 2006 (has links)
Made available in DSpace on 2016-12-06T17:07:11Z (GMT). No. of bitstreams: 1 dissertacao mestrado Luciane Balbinot.pdf: 3627256 bytes, checksum: a36fd0300702dcd6a0c22c892c0255a9 (MD5) Previous issue date: 2006-11-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Computerized thermography, system with ability to capture the infrared light emissivity of any reflexive surface, is part of the current arsenal of instrumentation in biomechanics. Using this methodology, it is possible to evaluate the physiology of thermical maintenance through its skin surface representation. The aim of this work is to evaluate the thermography as the identification method of myofascial trigger points, been chosen the trapezius muscle as study focus since it is one of most affected body regions concerning myofascial syndrome. This syndrome is highly prevalent and historically sub-diagnosticated as it requires expert professionals to establish its diagnostic, through physical examination. The articipants of this study were gathered as a sample of thirty persons, fifteen men and fifteen woman, ages between twenty three and seventy years (32,5 years in average). The algometry by pressure, highly validated method on previous works, has been used as part of physical examination to confirm the thermography events. The equipment used to collect the thermograms was an infrared camera with digital image processing, with thermical sensitivity for spectral ranges from 7 to 12 micrometers, appropriate for medical diagnostic utilization; the error index for measurement on this equipment is either 2% or 2oC. It has been used a dynamometer, clock type, for the algometry, commercially available for clinical use, which makes possible to evaluate the applied pressure to the focal point. The trigger point identification was based in a pain diagram filled by the own subject using previously validated parameters. The imaging evaluation was done using a descriptive analysis, having been taking in consideration the thermographic event corresponding to the trigger point, the hot spot or a discoid shaped surface, with one or more degrees Celsius hotter if compared to the neighbor reference point. Algometry was used in this work as reference method It was applied descriptive statistics for evaluate sensibility and specificity in trapezius Myofascial Syndrome diagnoses. A totality of 250 trigger points had been founded: 198 (79.20%) identified by algometry and thermography; 41 points (16.40%) by thermography only; 11(4.40%) identified by algometry only. It was concluded that the thermograpy is an appropriated method for Myofascial Syndrome diagnostic on trapezius muscle. / A termografia, sistema com capacidade de captar a emissividade de luz infravermelha de qualquer superfície reflexiva, faz parte do arsenal atual de instrumentação em biomecânica. Com esta metodologia pode-se avaliar a fisiologia da manutenção térmica através de sua representação cutânea. O presente trabalho teve por objetivo avaliar a termografia comptadorizada na identificação de trigger points miofasciais, tendo sido escolhido o músculo trapézio como foco de estudo, por esta ser uma das regiões corporais mais acometidas pela Síndrome Miofascial. Esta síndrome é altamente prevalente na população adulta ativa e, historicamente, sub-diagnosticada por requerer profissional especializado e treinado para estabelecer seu diagnóstico, que é através de exame físico. Os participantes deste estudo compunham uma amostra de trinta sujeitos, quinze homens e 15 mulheres, com idade entre 23 e 70 anos (média de 32,5 anos). A algometria de pressão, método validado amplamente em estudos prévios, foi utilizada como parte do exame físico para confirmação ou não dos eventos da termografia. O equipamento utilizado para coleta dos termogramas foi uma câmara de infravermelho com processamento digital de imagens, com sensibilidade térmica em faixa espectral de 7 a 12 micrômetros, adequada à sua aplicação no diagnóstico médico; o índice de incerteza de medição deste equipamento é de 2% ou 2ºC. Para a algometria, utilizou-se um dinamômetro tipo relógio, disponível comercialmente para uso clínico, que permitiu avaliar a pressão aplicada aos pontos de interesse. A identificação dos trigger points foi baseada em diagrama de dor preenchido pelo próprio sujeito e utilizando-se parâmetros previamente validados em publicações cientificas. A avaliação das imagens foi realizada através de análise descritiva, valorizando-se o evento termográfico correspondente ao trigger point, que é um hot spot ou, área em formato discóide, com hipertermia de um ou mais graus Celsius em relação a um ponto de referência circunvizinho. A algometria foi usada como método de referência neste estudo. Utilizou-se análise estatística descritiva dos dados para avaliar a sensibilidade e a especificidade da termografia no diagnóstico de Síndrome Miofascial de músculo trapézio. Foram identificados um total de 250 trigger points; destes, 198 (79,20%) foram identificados pela algometria e termografia simultaneamente; 41 pontos (16,40%) identificados apenas pela termografia e 11 pontos (4,40%) identificados apenas pela algometria. Concluiu-se que a termografia é eficaz na identificação de trigger points miofasciais de músculo trapézio.
178

Estudo da viabilidade da termografia na detecção de falha por desalinhamento paralelo vertical em acoplamento flexível. / Study of the thermography feasibility in the detection of the vertical parallel misalignment failure in flexible coupling.

OLINDA, Paulo Victor da Silva. 12 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-12T17:33:48Z No. of bitstreams: 1 PAULO VICTOR DA SILVA OLINDA – DISSERTAÇÃO (PPGEM) 2018.pdf: 4406932 bytes, checksum: 3015875e87b33898358c6dc22f3c9e3a (MD5) / Made available in DSpace on 2018-04-12T17:33:48Z (GMT). No. of bitstreams: 1 PAULO VICTOR DA SILVA OLINDA – DISSERTAÇÃO (PPGEM) 2018.pdf: 4406932 bytes, checksum: 3015875e87b33898358c6dc22f3c9e3a (MD5) Previous issue date: 2018-02-21 / Capes / O objetivo deste trabalho foi realizar um estudo termográfico visando constatar falha de montagem por desalinhamento em acoplamento flexível do tipo garra, modelo GR 50. A metodologia da pesquisa pode ser caracterizada como do tipo aplicada, quantitativa, explicativa, bibliográfica e experimental. Para tanto, montou-se uma bancada experimental contendo um motor trifásico, eixos, rolamentos e o acoplamento flexível, sem a presença de cargas, destinado a solidarizar dois eixos contendo desalinhamentos entre eles de 0,5; 0,74 e 1,18 mm. Como resultado dos testes efetuados, foi possível perceber que a temperatura do acoplamento aumenta à mesma proporção dos desalinhamentos inseridos, ou seja, quanto maior o desalinhamento, maior a temperatura registrada. Este fato é melhor observado nos primeiros 20 minutos dos testes. Diante destes resultados é possível afirmar que a Termografia pode ser utilizada como técnica de detecção de falhas de montagem por desalinhamento nos primeiros minutos de funcionamento do sistema. / The aim of this work is to perform a thermographic study aiming to verify assembly failure by mounting in flexible claw type coupling, model GR 50. A research methodology can be characterized as applied, quantitative, explanatory, bibliographic and experimental type. For this, an experimental bench was built, containing a three-phase motor, shafts, bearings and the flexible coupling, without a load presence, to join two shafts with misalignments between them; 0.5, 0.74 and 1.18 mm. As a result of the tests performed, it was possible to notice that the temperature of the coupling increases the same proportion of the misalignments inserted, that is, the greater the misalignment, the higher the temperature recorded. This fact is best observed in the first 20 minutes of the tests. In view of these results, it is possible to affirm that the thermography can be used as a technique for detecting mounting faults by misalignment in the first minutes of the system operation.
179

Sobreposição de imagens de termografia e ressonância magnética: uma nova modalidade de imagem médica tridimensional

Sanches, Ionildo José 2010 October 1914 (has links)
A termografia por imagem infravermelha é uma técnica para diagnóstico não-invasivo que permite a avaliação e quantificação de mudanças de temperatura na superfície da pele. Uma vez que as variações de temperatura na superfície do corpo humano são contínuas, é difícil a associação de detalhes anatômicos bem como, associar as variações de temperatura da pele com as estruturas ou órgãos internos. Apesar de fornecer informações significativas para o diagnóstico médico, esta técnica não permite avaliar detalhes anatômicos da região estudada. Este trabalho apresenta uma nova metodologia para fusão de imagens de ressonância magnética 3D (ou tomografia computadorizada) e imagens infravermelhas (2D). O resultado é uma imagem termográfica 3D que pode auxiliar no diagnóstico médico de certas doenças, tais como insuficiência vascular periférica, pé-diabético, tumores de mama e tireóide, sinusite, cefaléia, doenças reumáticas e outros processos inflamatórios, isto é, doenças que podem ser diagnosticadas pelo mapeamento térmico da superfície do corpo. No desenvolvimento deste trabalho pluridisciplinar de Engenharia Biomédica, foram utilizados conhecimentos de Processamento Digital de Imagens, Computação Gráfica, Visão Computacional, Programação de Computadores, Radiologia, Imageamento Médico e Termografia, interagindo com áreas da Medicina, da Ciência da Computação e da Engenharia Elétrica. Em um primeiro experimento, são adquiridas as imagens por ressonância magnética (MRI) da região de interesse. Em um segundo experimento, adquire-se um conjunto de imagens térmicas. Gera-se projeções 2D a partir dos planos tomográficos na mesma direção/orientação do conjunto de imagens tomográficas. Em seguida realiza-se o registro desses dois conjuntos de imagens. Após o registro, as imagens térmicas são combinadas e projetadas sobre o modelo 3D das imagens de MRI ou CT. O resultado é uma imagem que combina informação de duas modalidades de imagens médicas diferentes. Os excelentes resultados obtidos com essa nova metodologia demonstram que ela pode auxiliar no diagnóstico médico. / Infrared (IR) imaging is a noninvasive diagnostic technique that allows the examiner to evaluate and quantify changes on skin surface temperature. Since changes over the human body surface temperature are continuous, it is difficult to associate anatomical details, as well to associate skin temperature with internal structures or organs. Though providing significant information to clinical diagnosis, this technique does not allow evaluating anatomical details of the imaged region. In this work it is presented a new image fusion method for combining 3D Magnetic Resonance Images (or Computed Tomography) and 2D thermal images. The result is a 3D thermographic imaging that can improve medical diagnosis of certain human diseases, such as peripheral vascular disease, diabetic foot, breast and thyroid tumors,sinusitis, cephalalgia, rheumatic disorder and others inflammations process, i.e., diseases that can be diagnosis through the body surface thermal mapping. In the development of this interdisciplinary work of Biomedical Engineering, the knowledge of Digital Image Processing, Computer Graphics, Machine Vision, Computer Programming, Radiology, Medical Imaging and Thermography, was necessary, interacting with areas of Medicine,Computer Science and Electrical Engineering. First, magnetic resonance images (MRI) or computed tomography (CT) from region of interest are acquired. In a second experiment, a set of IR images is acquired. From the MRI or CT data, 2D projections are generated in the same direction/orientation of the tomographic planes. Then, the generated projections and the IR images are registered. Next, the registered IR images set is combined and projected over the 3D-MRI or 3D-CT. The result is a fused image that combines the information contents from two different medical images modalities. The excellent results obtained with the new methodology demonstrate that it can aid medical diagnosis.
180

Sobreposição de imagens de termografia e ressonância magnética: uma nova modalidade de imagem médica tridimensional

Sanches, Ionildo José 2010 October 1914 (has links)
A termografia por imagem infravermelha é uma técnica para diagnóstico não-invasivo que permite a avaliação e quantificação de mudanças de temperatura na superfície da pele. Uma vez que as variações de temperatura na superfície do corpo humano são contínuas, é difícil a associação de detalhes anatômicos bem como, associar as variações de temperatura da pele com as estruturas ou órgãos internos. Apesar de fornecer informações significativas para o diagnóstico médico, esta técnica não permite avaliar detalhes anatômicos da região estudada. Este trabalho apresenta uma nova metodologia para fusão de imagens de ressonância magnética 3D (ou tomografia computadorizada) e imagens infravermelhas (2D). O resultado é uma imagem termográfica 3D que pode auxiliar no diagnóstico médico de certas doenças, tais como insuficiência vascular periférica, pé-diabético, tumores de mama e tireóide, sinusite, cefaléia, doenças reumáticas e outros processos inflamatórios, isto é, doenças que podem ser diagnosticadas pelo mapeamento térmico da superfície do corpo. No desenvolvimento deste trabalho pluridisciplinar de Engenharia Biomédica, foram utilizados conhecimentos de Processamento Digital de Imagens, Computação Gráfica, Visão Computacional, Programação de Computadores, Radiologia, Imageamento Médico e Termografia, interagindo com áreas da Medicina, da Ciência da Computação e da Engenharia Elétrica. Em um primeiro experimento, são adquiridas as imagens por ressonância magnética (MRI) da região de interesse. Em um segundo experimento, adquire-se um conjunto de imagens térmicas. Gera-se projeções 2D a partir dos planos tomográficos na mesma direção/orientação do conjunto de imagens tomográficas. Em seguida realiza-se o registro desses dois conjuntos de imagens. Após o registro, as imagens térmicas são combinadas e projetadas sobre o modelo 3D das imagens de MRI ou CT. O resultado é uma imagem que combina informação de duas modalidades de imagens médicas diferentes. Os excelentes resultados obtidos com essa nova metodologia demonstram que ela pode auxiliar no diagnóstico médico. / Infrared (IR) imaging is a noninvasive diagnostic technique that allows the examiner to evaluate and quantify changes on skin surface temperature. Since changes over the human body surface temperature are continuous, it is difficult to associate anatomical details, as well to associate skin temperature with internal structures or organs. Though providing significant information to clinical diagnosis, this technique does not allow evaluating anatomical details of the imaged region. In this work it is presented a new image fusion method for combining 3D Magnetic Resonance Images (or Computed Tomography) and 2D thermal images. The result is a 3D thermographic imaging that can improve medical diagnosis of certain human diseases, such as peripheral vascular disease, diabetic foot, breast and thyroid tumors,sinusitis, cephalalgia, rheumatic disorder and others inflammations process, i.e., diseases that can be diagnosis through the body surface thermal mapping. In the development of this interdisciplinary work of Biomedical Engineering, the knowledge of Digital Image Processing, Computer Graphics, Machine Vision, Computer Programming, Radiology, Medical Imaging and Thermography, was necessary, interacting with areas of Medicine,Computer Science and Electrical Engineering. First, magnetic resonance images (MRI) or computed tomography (CT) from region of interest are acquired. In a second experiment, a set of IR images is acquired. From the MRI or CT data, 2D projections are generated in the same direction/orientation of the tomographic planes. Then, the generated projections and the IR images are registered. Next, the registered IR images set is combined and projected over the 3D-MRI or 3D-CT. The result is a fused image that combines the information contents from two different medical images modalities. The excellent results obtained with the new methodology demonstrate that it can aid medical diagnosis.

Page generated in 0.0842 seconds