• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • 1
  • Tagged with
  • 10
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Récupération et valorisation d'énergie thermique sur gaz chauds- Approche expérimentale et numérique / Contribution to Waste Thermal Energy Recovery on Hot Gases by Heat Pipe Heat Exchanger - Expeirmental Approach and Modeling

Hoang, Thanh Tung 30 November 2018 (has links)
L’objectif de la thèse porte sur l’analyse de la récupération de l’énergie thermique sur gaz chauds à température élevée(250°C - 450°C). Pour cela, la technologie de récupérateur à caloduc de type thermosiphon a été retenue. L’un des points cruciaux porte sur le choix d’un fluide de travail adapté à ces niveaux de température. Une analyse bibliographique a permis d’identifier le naphtalène comme élément de fluide potentiel pour cette gamme de température. Cependant le manque d’informations sur son comportement et ses capacités de transport a nécessité le développement d’un montage fondamental spécifique.Un caloduc thermosiphon chargé en naphtalène et de la forme d’un tube inox lisse de diamètre 23,9 mm, de longueur 1m (zone évaporateur : 20 cm ; zone condenseur : 20 cm) a été réalisé et testé. Les résultats expérimentaux obtenus démontrent tout d’abord la faisabilité d’un tel système dans cette gamme de température et pour les puissances thermiques envisagées. Ils révèlent un comportement inhabituel du thermosiphon lors des phases de démarrage (régime transitoire). En régime permanent, l’analyse a porté sur l’influence de la température de saturation, la puissance transférée ainsi que l’inclinaison. En termes de performances, les conductances thermiques (évaporateur, condenseur, système) augmentent avec la température vapeur et diminuent avec la puissance apportée à l’évaporateur. La puissance transférée peut s’échelonner de 0,2 kW à 1,5 kW, soit 1 à 8 W/cm² à l’évaporateur. Une faible sensibilité à l’inclinaison a été constatée lors des tests (0°-78°), un peu plus marqué pour 84°. Enfin pour une orientation à l’horizontale (90°), le caloduc fonctionne malgré tout et sa capacité de transfert reste élevée bien qu’éloignée du mode thermosiphon. En parallèle, un modèle de thermosiphon a été développé dans lequel les coefficients d’échanges locaux (évaporateur et condenseur) sont calculés par différentes corrélations issues de la littérature. La comparaison avec les résultats expérimentaux a permis de valider les modèles physiques retenus avec un bon accord, et de prédire le fonctionnement du caloduc pour d’autres sollicitations.Ainsi et enfin, un premier prototype récupérateur à thermosiphon au naphtalène a été conçu, fabriqué et couplé sur la veine « gaz chauds » conçue et développée aussi au sein du laboratoire. Les premiers résultats obtenus du système complet permettent de développer des stratégies de récupération et de valorisation de l’énergie thermique sur la ligne d’échappement, dans un contexte d’application automobile. / The aim of the thesis is to analyze the heat recovery on hot gases at intermediate temperature range (250°C - 450°C). For this purpose, the thermosyphon heat exchanger recuperation technology has been chosen. The choice of a working fluid adapted to these temperature levels is one of the crucial points. A literature review identified naphthalene as a potentialfluid for this temperature range. However, because of the lack of information about naphthalene heat pipes, the development of a fundamental test-rig was necessary to fully characterize the thermal behavior and transport capacities of this fluid.A thermosyphon heat-pipe charged with naphthalene in the shape of a smooth stainless steel tube with a diameter of 23.9mm, a length of 1 m (evaporator zone: 20 cm, condenser zone: 20 cm) has been manufactured and tested. The experimental results obtained demonstrate the feasibility of such system in this temperature range and for the thermal powers required.They reveal an unusual behavior of the thermosyphon during the start-up process. In steady state, the analysis deals with the influence of the saturation temperatures, the transferred heat power and the thermosyphon inclination. In terms of performances, the thermal conductance (evaporator, condenser, system) increases with the vapor temperature and decreases with the heat power supplied to the evaporator. The heat flow rate can be applied from 0.2 to 1.5 kW, or 1 to 8W/cm² at the evaporator. During the tests, the system is found to be less sensitive to inclination (0° to 78°), but more important for 84°. In the horizontal position, the thermosyphon operates, but its heat transfer remains high even far away from the thermosyphon mode. A theoretical model has been developed in which the local heat transfer coefficients(evaporator and condenser) are evaluated by different correlations from literature. The comparison with the experimental results allowed to validate the models retained with good agreement, and to make it possible to predict the heat pipe operation for other solicitations.Thus, and finally, a first thermosyphon charged naphthalene recuperator prototype was designed, manufactured and coupled to the "hot gas" line designed and performed in the laboratory. The first results obtained from the complete system allowed us to develop a strategy for heat recovery system on the exhaust line of an automotive application.
2

Passive thermal management of distribution grid assets

Hesse, Danielle 07 January 2016 (has links)
This thesis presents a comprehensive study into the passive thermal management of high-voltage power electronics converters for use in augmented grid assets capable of performing power routing on the electricity grid. The work has focused on the thermal transport of single-phase closed thermosiphon systems incorporating a secondary parallel flow path for cooling an additional, typically smaller, thermal load associated with the power electronics converters. Dual-loop thermosiphon passive thermal management systems were incorporated into a grounded compact dynamic phase angle regulator (GCD-PAR) that aimed to facilitate power routing and reduce line losses on the power grid. The power router utilizes power electronics that reject heat to a planar area, or cold plate, which must be cooled by an entirely passive system to comply with the minimum 30 year mean time between failures (MTBF) consistent with grid reliability requirements. This design includes a secondary-loop cooling path that utilizes the cooling oil already present in the transformer to also cool the power router. An analytical multi-physics thermosiphon model is developed that couples existing fluid dynamic and heat transfer correlations to create a description of the steady state operation of a specific cylindrical 50 kVA transformer augmented with a thermosiphon. The model is validated experimentally and found to solve for steady state baseplate temperatures under maximum load within 2°C in 0.1 seconds. The model is then modified for a specific rectilinear 1 MVA transformer augmented with three thermosiphons. The 1 MVA model is validated experimentally and found to solve for steady state baseplate temperatures under maximum load within 4 °C in 0.2 seconds. The analytical model proves to be accurate and solve quickly with various geometric configurations and thermal loads.
3

Numerical and Experimental Study of Heat Pipes Used in Solar Applications / Étude numérique, par la méthode de Boltzmann sur réseau, et expérimentale des caloducs utilisés dans les applications solaires

Grissa, Kods 18 December 2018 (has links)
En raison de la tendance positives pour le développement durable, les systèmes solaires(capteurs solaires, concentrateur solaire, etc.) Intègrent (et demandent d'intégrer encore plus)intensivement les résidences et les industries. Dans ce contexte, les systèmes diphasiques comme le caloduc semblent être très efficaces en raison de leurs capacités élevées de transport de chaleur et de leur fonctionnement passif appliqués aux capteurs. Compte-tenu de la complexité des caloducs à structure poreuse dans ce type d'application, la plupart des systèmes existants sur le marché utilisent des thermosiphons. Ainsi, le besoin croissant de solutions de contrôle thermique fiables et plus efficaces croit rapidement pour de tels systèmes.Ce travail de thèse porte sur la caractérisation des performances des caloducs à structure poreuse utilisés dans les applications solaires. Une étude numérique a été réalisée pour modéliser et simuler le comportement d'un caloduc typique à l'aide de la méthode Lattice Boltzmann. Une étude expérimentale a également été réalisée pour caractériser les performances de trois prototypes testes dans différentes conditions (température du condenseur, puissance introduite et angle d'inclinaison). Les effets induits par plusieurs paramètres incluant le taux de remplissage, le fluide de travail et la symétrie de la puissance appliquée sur les performances de ces dispositifs ont également été étudiés. En particulier, l'asymétrie du chauffage induit un assèchement plus précoce, toutes choses étant égales par ailleurs. L'inclinaison optimale est également déterminée là où est équilibrée la chaleur solaire maximale disponible et reçue par le caloduc et l'écoulement de liquide assisté par gravité à l'intérieur de ce dispositif. / Owing to the trend to development sustainability, solar systems (solar collector, solar concentrator, etc.) Are integrating (and asked to integrate even more) intensively residences and industries. In this context, two-phase systems like heat pipe seem highly effective because of their high heat transport capabilities and their passive operation in collectors’ technology. In view of the complexity of the heat pipes with a porous structure in this kind of application,most of the existing systems on the market use thermosyphons. Thus, the growing need of reliable and more efficient thermal control solutions is increasing for such systems. This thesis work focuses on the performance characterization of heat pipes with porous structure used in solar applications. A numerical study has been performed to model and simulate the behavior of a typical heat pipe using the Lattice Boltzmann method. An experimental study has also been done to characterize the performance of three prototypes tested under different conditions (condenser temperature, heat input and inclination angle). The effects induced by several parameters including the filling rate, working fluid and symmetry of the applied heat on the performance of these devices has also been investigated. In particular, heating asymmetry is found to induce dry-out earlier, all other things being equal. Optimal inclination is also determined where is balanced the maximum solar heat available and received by the heat pipe and the gravity-assisted liquid flow inside that device.
4

Evaluation of sealed storage silos for grain fumigation

Cook, Samuel A.L. January 1900 (has links)
Master of Science / Department of Grain Science and Industry / Dirk E. Maier / Fumigation of stored grain is a common way to kill stored-grain insect pests. However, fumigating in unsealed structures is the leading cause of control failures and subsequent development of insect resistance. Sealing the storage structure is the only practical way to ensure a complete kill of all insects at all life stages. The cost, effort, and feasibility of sealing a U.S. corrugated steel silo during construction was evaluated and compared against an Australian sealed silo designed for fumigation. Gas monitoring and thermosiphon recirculation equipment was installed on both silos. Fumigation efficacy was evaluated using pressure half-life decay times, fumigant concentrations, insect bioassays, and grain quality data. Three fumigations with phosphine (PH₃) pellets or tablets and two with VAPORPH₃OS® cylinderized PH₃ and ProFume® cylinderized sulfuryl fluoride (SF) were performed in each silo for a total of ten experimental treatments. The Australian silo required 266 man-hours to construct and cost $180 for additional sealing, compared to 359 man-hours and $3,284 for constructing and sealing the U.S. silo. The Australian silo had a maximum pressure half-life decay time of 163 s versus 50 s for the U.S. silo. At application rates of 1.5 g/mᶟ of PH₃ both silos maintained an average concentration of approximately 0.28 g/mᶟ for 14 days. With thermosiphon recirculation the average minimum-to-maximum PH₃ concentration ratio in the U.S. silo was 0.52, compared to a ratio of 0.17 when fumigating without thermosiphon recirculation. Greater than 99% adult mortality was observed in all insect bioassays which included PH₃ resistant strains of R. dominica and T. castaneum. The average emergence from fumigated bioassays was 7 adult insects, compared to an average of 383 adults for the non-fumigated controls. Grain stored for 10 months in the sealed silos increased from approximately 11.5% to 17% m.c. in the top 0.3 m of grain, and decreased in test weight from approximately 77 to 65 kg/hL. Although the Australian silo retained higher fumigant concentrations than the U.S. silo, fumigations were successful in both. Long-term storage in sealed silos is a concern because grain quality can deteriorate due to condensation and mold in the top grain layer.
5

Evaluation de l'impact des isolants minces réfléchissants dans le bâtiment

Chami, Nada 19 October 2009 (has links) (PDF)
Ce travail met la lumière sur les performances d'une technique d'isolation de l'enveloppe du bâtiment par produits minces réfléchissants (PMR). Cette technique regroupe la performance isolante d'un matériau ainsi que celle d'une lame d'air fermée à la réduction des transferts radiatifs en utilisant une barrière à faible émissivité thermique. Le marché de ces produits s'est développé rapidement alors qu'ils ne sont pas certifiés et qu'il existe une controverse sur les performances effectives qu'ils peuvent atteindre une fois intégrés dans le bâtiment. L'objectif principal a donc été de réaliser une caractérisation complète de ces produits intégrés dans les parois verticales du bâtiment et les combles, par modélisation et par étude expérimentale, pour obtenir une meilleure connaissance des phénomènes physiques induits par ce type de produits d'isolation. Un modèle thermique de paroi complexe intégrant un PMR a été réalisé. Une étude numérique préliminaire a permis de caractériser l'échange convectif à l'intérieur des lames d'air non ventilées. Les résultats de performances thermiques ont été validés par une étude expérimentale basée sur le principe de la boîte chaude. Un modèle de rampant de toiture intégrant un PMR a été également réalisé. Pour la période estivale, la lame d'air ventilée conçue entre les tuiles et le produit réfléchissant a été étudiée par une modélisation numérique et des mesures par PIV. Le facteur de transmission solaire du complexe de rampant a été déterminé en variant plusieurs paramètres. Pour la période hivernale, les performances thermiques ont été calculées en prenant en compte l'effet du vent et la perméabilité des tuiles sur la lame d'air ventilée. Les résultats ont montré que ces produits, utilisés comme isolation unique, ne répondent pas aux exigences règlementaires. Installés en complément, ils ont l'avantage d'augmenter le confort d'été au niveau des combles aménagés en période ensoleillée.
6

Modeling and optimization of a thermosiphon for passive thermal management systems

Loeffler, Benjamin Haile 15 November 2012 (has links)
An optimally designed thermosiphon for power electronics cooling is developed. There exists a need for augmented grid assets to facilitate power routing and decrease line losses. Power converter augmented transformers (PCATs) are critically limited thermally. Conventional active cooling system pumps and fans will not meet the 30 year life and 99.9% reliability required for grid scale implementation. This approach seeks to develop a single-phase closed-loop thermosiphon to remove heat from power electronics at fluxes on the order of 10 - 15 W/cm2. The passive thermosiphon is inherently a coupled thermal-fluid system. A parametric model and multi-physics design optimization code will be constructed to simulate thermosiphon steady state performance. The model will utilize heat transfer and fluid dynamic correlations from literature. A particle swarm optimization technique will be implemented for its performance with discrete domain problems. Several thermosiphons will be constructed, instrumented, and tested to verify the model and reach an optimal design.
7

Experimental and Numerical Investigation of Solar Airflow Windows

Friedrich, Kelton E. 10 1900 (has links)
<p>Solar thermosiphons integrated into the thermal envelop of buildings has been studied for their potential to take advantage of solar energy in heating buildings. The annual performance of solar thermosiphons cannot currently be predicted with the correlations from previous research. Also, no work has been done on the supply mode of a solar thermosiphon even though it has the potential to provide heating and fresh ventilation air. An investigation was done with the goal of developing a numerical model that could predict the performance of the supply mode of a solar thermosiphon. The numerical model included infrared thermal radiation and conduction through the glass, phenomenon which had not been used in previous numerical models. To validate the numerical model a novel steady state experiment was developed. This experiment included radiation as the heat source and the ability to vary geometric lengths. The performance parameters of mass flow rate and thermal efficiency were comparable between the numerical predictions and experimental results. However, due to uncertainties in the current experimental setup, full validation of the numerical model was not possible. These uncertainties would have to be addressed before the numerical model that was developed can be fully validated and used for generating correlations. After consideration of practical implementation constrains, it was shown that it was easier to implement the indoor air curtain mode of a solar thermosiphon than the supply mode. The indoor air curtain mode provides the same amount of energy from solar radiation to heat a building as the supply mode of a solar thermosiphon.</p> / Master of Applied Science (MASc)
8

Contribution à l'étude des propriétés thermiques et hydrodynamiques d'un écoulement d'hélium normal (5HeI) diphasique en circulation naturelle pour le refroidissement des aimants supraconducteurs / Contribution to the study of thermal and hydrodynamical properties of HeI two phase natural circulation flow for cooling superconducting magnets

Benkheira, Lahcène 29 June 2007 (has links)
La méthode de refroidissement basée sur le principe thermosiphon présente un grand intérêt en raison de sa simplicité, de sa nature passive et de son coût faible. Elle est adoptée pour le refroidissement à 4,5 K de l’aimant supraconducteur du détecteur de particules CMS auprès du LHC en construction au CERN à Genève. Le travail présenté dans cette thèse étudie expérimentalement les propriétés thermiques et hydrodynamiques d’un écoulement d’He I diphasique en circulation naturelle. Le dispositif expérimental utilisé consiste en une boucle thermosiphon monobranche composée principalement d’un séparateur de phases, d’un tube descendant et d’une section d’essai. Les expériences ont été réalisées en faisant varier plusieurs paramètres tels que le diamètre des sections d’essai (10 mm ou 14 mm) et le flux de chaleur allant jusqu’à l’apparition de la crise d’ébullition. Ces expériences ont permis de déterminer les lois d’évolution des différentes grandeurs caractérisant l’écoulement (le débit massique de circulation, le débit massique vapeur, le titre massique, le coefficient de friction et le coefficient d’échange thermique) en fonction de la densité du flux de chaleur appliquée. Au regard des résultats obtenus, nous discutons la validité des différents modèles classiques existants dans la littérature. Nous montrons que le modèle homogène est le modèle le mieux adapté pour prédire les propriétés hydrodynamiques de ce type d’écoulement dans la gamme de titre massique 0?x?30%. De plus, nous proposons deux modèles pour la prédiction du coefficient de transfert de chaleur diphasique et la densité de flux de chaleur critique. Le premier considère que les effets de la convection forcée et de l’ébullition nucléée agissent simultanément et contribuent au transfert de chaleur. Le deuxième corrèle la densité de flux de chaleur critique mesurée en fonction du rapport altitude sur diamètre / The method of cooling based on the thermosiphon principle is of great interest because of its simplicity, its passivity and its low cost. It is adopted to cool down to 4,5 K the superconducting magnet of the CMS particles detector of the Large Hadron Collider (LHC) experiment under construction at CERN, Geneva. This work studies heat and mass transfer characteristics of two phase He I in a natural circulation loop. The experimental set-up consists of a thermosiphon single branch loop mainly composed of a phase separator, a downward tube, and a test section. The experiments were conducted with varying several parameters such as the diameter of the test section (10 mm or 14 mm) and the applied heat flux up to the appearance of the boiling crisis. These experiments have permitted to determine the laws of evolution of the various parameters characterizing the flow (circulation mass flow rate, vapour mass flow rate, vapour quality, friction coefficient, two phase heat transfer coefficient and the critical heat flux) as a function of the applied heat flux. On the base of the obtained results, we discuss the validity of the various existing models in the literature. We show that the homogeneous model is the best model to predict the hydrodynamical properties of this type of flow in the vapour quality range 0?x?30%. Moreover, we propose two models for the prediction of the two phase heat transfer coefficient and the density of the critical heat flux. The first one considers that the effects of the forced convection and nucleate boiling act simultaneously and contribute to heat transfer. The second one correlates the measured critical heat flux density with the ratio altitude to diameter
9

Refroidissement d'une armoire de Télécommunication avec Bouche Diphasique Thermosyphon

Mecheri, Boubakeur 17 February 2011 (has links) (PDF)
France Télécom possède des armoires de télécommunication dont la puissance est limitée à cause de la dissipation thermique des équipements actifs qui entraîne une augmentation de leur température interne. La puissance des équipements limite le nombre de clients qu'il est possible de connecter aux services des réseaux à hauts débits. En plus de cette contrainte, les armoires sont soumises à des effets liés au climat (ensoleillement) qui peuvent être sévères et difficiles à maîtriser. Ceci nécessite l'intégration de systèmes de refroidissement permettant de maintenir la température des composants en dessous de la limite imposée (55°C). C'est dans cet objectif que ce travail de thèse a été mené au sein du laboratoire FEMTO-ST en collaboration avec le service R&D de France Télécom à Lannion. Le refroidissement par changement de phase est favorisé pour maintenir la température de fonctionnement du système stable et pour être utilisé dans les systèmes à haute densité de puissance. Les boucles diphasiques sont des systèmes de refroidissement pour le contrôle thermique et fonctionnent passivement sans pompage mécanique du fluide caloporteur. Après une étude bibliographique sur les boucles de refroidissement diphasiques et leurs applications, on a constaté que les boucles thermosiphons sont particulièrement adaptées aux applications où le faible coût, l'efficacité énergétique et la fiabilité d'entretien sont souhaités. Cette étude a été conduite en suivant un cahier de charge proposé par France Télécom qui consiste à : (i) développer un modèle numérique permettant de modéliser les transferts échangés entre l'armoire de télécommunication et le milieu ambiant, (ii) mener une étude expérimentale en vue de concevoir une boucle thermosiphon pour le refroidissement d'armoires de télécommunication.Le mémoire de cette thèse montre la limitation des systèmes de refroidissement classiques utilisant des écoulements d'air en convection forcée ou autre fluides sans changement de phase. Un modèle numérique est développé afin de permettre la prédiction des températures à l'entrée des boitiers chauffants pour différentes conditions climatiques. Le choix est porté sur l'utilisation d'une modélisation par réseau nodal. La modélisation est effectuée en tridimensionnel et en régime transitoire. Nous avons également modélisé le rayonnement solaire auquel est soumise l'armoire de télécommunication. Le modèle développé a été validé en effectuant une comparaison entre les résultats issus de la modélisation et ceux obtenus à partir des expériences menées au laboratoire et à la plateforme CLIMA chez France Télécom. Les essais sont effectués en régime transitoire en imposant une puissance électrique et en faisant varier la température ambiante ou la densité de flux thermique solaire. L'ensemble des résultats obtenus ont permis de constituer une base de données. Le deuxième objectif fixé dans le cadre de ce travail de thèse est la conception d'un système de refroidissement sous forme d'une boucle thermosiphon. La contrainte principale qui a guidée cette conception était le fait que la boucle doit refroidir l'armoire et assurer une température d'air à l'entrée des équipements inférieure à la limite imposée par la norme ETSI. Ceci nous a mené à concevoir un prototype de boucle thermosiphon dont la puissance thermique qu'il doit dissiper est imposée. On a montré que ce prototype permet de dissiper des puissances thermiques allant jusqu'à 470 W en utilisant une petite charge de npentane. Nous avons effectué des essais sur le refroidissement du prototype d'armoire de télécommunication en utilisant la boucle thermosiphon légèrement modifiée. On montre que les performances thermiques obtenues en utilisant un mode de refroidissement en boucle thermosiphon sont meilleures. Les boucles thermosiphons semblent intéressantes pour un refroidissement passif de matériels déployés dans un réseau de télécommunication...
10

Refroidissement d'une armoire de Télécommunication avec Bouche Diphasique Thermosyphon / Two-phase cooling of a telecomunication cabinet

Mecheri, Boubakeur 17 February 2011 (has links)
France Télécom possède des armoires de télécommunication dont la puissance est limitée à cause de la dissipation thermique des équipements actifs qui entraîne une augmentation de leur température interne. La puissance des équipements limite le nombre de clients qu'il est possible de connecter aux services des réseaux à hauts débits. En plus de cette contrainte, les armoires sont soumises à des effets liés au climat (ensoleillement) qui peuvent être sévères et difficiles à maîtriser. Ceci nécessite l’intégration de systèmes de refroidissement permettant de maintenir la température des composants en dessous de la limite imposée (55°C). C’est dans cet objectif que ce travail de thèse a été mené au sein du laboratoire FEMTO-ST en collaboration avec le service R&D de France Télécom à Lannion. Le refroidissement par changement de phase est favorisé pour maintenir la température de fonctionnement du système stable et pour être utilisé dans les systèmes à haute densité de puissance. Les boucles diphasiques sont des systèmes de refroidissement pour le contrôle thermique et fonctionnent passivement sans pompage mécanique du fluide caloporteur. Après une étude bibliographique sur les boucles de refroidissement diphasiques et leurs applications, on a constaté que les boucles thermosiphons sont particulièrement adaptées aux applications où le faible coût, l'efficacité énergétique et la fiabilité d’entretien sont souhaités. Cette étude a été conduite en suivant un cahier de charge proposé par France Télécom qui consiste à : (i) développer un modèle numérique permettant de modéliser les transferts échangés entre l’armoire de télécommunication et le milieu ambiant, (ii) mener une étude expérimentale en vue de concevoir une boucle thermosiphon pour le refroidissement d’armoires de télécommunication.Le mémoire de cette thèse montre la limitation des systèmes de refroidissement classiques utilisant des écoulements d’air en convection forcée ou autre fluides sans changement de phase. Un modèle numérique est développé afin de permettre la prédiction des températures à l’entrée des boitiers chauffants pour différentes conditions climatiques. Le choix est porté sur l’utilisation d’une modélisation par réseau nodal. La modélisation est effectuée en tridimensionnel et en régime transitoire. Nous avons également modélisé le rayonnement solaire auquel est soumise l’armoire de télécommunication. Le modèle développé a été validé en effectuant une comparaison entre les résultats issus de la modélisation et ceux obtenus à partir des expériences menées au laboratoire et à la plateforme CLIMA chez France Télécom. Les essais sont effectués en régime transitoire en imposant une puissance électrique et en faisant varier la température ambiante ou la densité de flux thermique solaire. L’ensemble des résultats obtenus ont permis de constituer une base de données. Le deuxième objectif fixé dans le cadre de ce travail de thèse est la conception d’un système de refroidissement sous forme d’une boucle thermosiphon. La contrainte principale qui a guidée cette conception était le fait que la boucle doit refroidir l’armoire et assurer une température d’air à l’entrée des équipements inférieure à la limite imposée par la norme ETSI. Ceci nous a mené à concevoir un prototype de boucle thermosiphon dont la puissance thermique qu’il doit dissiper est imposée. On a montré que ce prototype permet de dissiper des puissances thermiques allant jusqu’à 470 W en utilisant une petite charge de npentane. Nous avons effectué des essais sur le refroidissement du prototype d’armoire de télécommunication en utilisant la boucle thermosiphon légèrement modifiée. On montre que les performances thermiques obtenues en utilisant un mode de refroidissement en boucle thermosiphon sont meilleures. Les boucles thermosiphons semblent intéressantes pour un refroidissement passif de matériels déployés dans un réseau de télécommunication... / France Telecom owns telecommunication cabinets whose power is limited because of the heat dissipation of active devices which leads to increased internal temperature. Power equipment limits the number of clients that can connect to networks services with high data rates. In addition to this constraint, the cabinets are subject to climate-related impacts (sunlight) that can be severe and difficult to master. This requires the integration of cooling systems to maintain the temperature of components below the limit (55 ° C). It is with this aim that this work was conducted in the laboratory Femto-ST in collaboration with the R & D department of France Telecom in Lannion.Cooling the phase change is promoted to maintain the operating temperature of the stable and system for use in systems with high power density. The loops are two-phase cooling systems for thermal control and operate passively without mechanical pumping of the coolant.After a literature review on two-phase cooling loops and their applications, it was found that the thermosyphon loops are particularly suitable for applications where low cost, energy efficiency and reliability maintenance are desired. This study was conducted by following a set of specifications proposed by France Telecom which involves: (i) develop a numerical model to model transfers exchanged between the cabinet and the telecommunications environment, (ii) conduct an experimental study to design a thermosyphon loop for cooling telecommunication cabinets.The memory of this thesis shows the limitation of conventional cooling systems using air flow forced convection or other fluids without phase change. A numerical model is developed to enable the prediction of temperatures at the inlet of heated enclosures for different climatic conditions. The choice is focused on the use of a nodal network modeling. The modeling is done by three-dimensional and transient. We also modeled the solar radiation, which applies to the telecommunications closet. The developed model was validated by comparison between the results of modeling and those obtained from experiments in the laboratory and platform CLIMA at France Telecom. The tests are performed by imposing transient electrical power and varying the temperature or heat flux density solar. All the results obtained allowed to establish a database.The second goal as part of this thesis is the design of a cooling system as a thermosyphon loop. The main constraint has guided this design was that the loop needs to cool the cabinet and provide air temperature at the inlet of the equipment below the limit imposed by the ETSI. This led us to design a prototype of thermosyphon loop with a heat output that must be dissipated is imposed. We showed that this prototype is used to dissipate the heat ratings up to 470 W using a small load of npentane.We conducted tests on the prototype cooling telecommunication cabinet using slightly modified thermosyphon loop. We show that the thermal performance obtained by using a cooling mode loop thermosyphon are better. Thermosyphon loops seem interesting for passive cooling of equipment deployed in a telecommunications network. Indeed, being able to use an air conditioning system independent and requires no energy should be promoted in a reduction of overall energy consumption.

Page generated in 0.4883 seconds