• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 178
  • 22
  • 19
  • 15
  • 8
  • 6
  • 6
  • 5
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 299
  • 299
  • 137
  • 123
  • 55
  • 38
  • 37
  • 36
  • 32
  • 31
  • 31
  • 30
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

3D imaging using time-correlated single photon counting

Neimert-Andersson, Thomas January 2010 (has links)
<p>This project investigates a laser radar system. The system is based on the principles of time-correlated single photon counting, and by measuring the times-of-flight of reflected photons it can find range profiles and perform three-dimensional imaging of scenes. Because of the photon counting technique the resolution and precision that the system can achieve is very high compared to analog systems. These properties make the system interesting for many military applications. For example, the system can be used to interrogate non-cooperative targets at a safe distance in order to gather intelligence. However, signal processing is needed in order to extract the information from the data acquired by the system. This project focuses on the analysis of different signal processing methods.</p><p>The Wiener filter and the Richardson-Lucy algorithm are used to deconvolve the data acquired by the photon counting system. In order to find the positions of potential targets different approaches of non-linear least squares methods are tested, as well as a more unconventional method called ESPRIT. The methods are evaluated based on their ability to resolve two targets separated by some known distance and the accuracy with which they calculate the position of a single target, as well as their robustness to noise and their computational burden.</p><p>Results show that fitting a curve made of a linear combination of asymmetric super-Gaussians to the data by a method of non-linear least squares manages to accurately resolve targets separated by 1.75 cm, which is the best result of all the methods tested. The accuracy for finding the position of a single target is similar between the methods but ESPRIT has a much faster computation time.</p>
242

Characterisation of the Neutron Wall and of Neutron Interactions in Germanium-Detector Systems

Ljungvall, Joa January 2005 (has links)
<p>A Monte Carlo simulation of the Neutron Wall detector system has been performed using Geant4, in order to define optimum conditions for the detection and identification of multiple neutrons. Emphasis was put on studying the scattering of neutrons between different detectors, which is the main source of the apparent increase of the number of detected neutrons. The simulation has been compared with experimental data. The quality of neutron gated γ-ray spectra was improved for both two- and three-neutron evaporation channels. The influence of small amounts of γ rays mis-interpreted as neutrons was investigated. It was found that such γ rays dramatically reduce the quality of neutron gated γ-ray spectra.</p><p>The interaction properties of fast neutrons in a closed-end coaxial and a planar high-purity germanium detector (HPGe) were studied. Digitised waveforms of HPGe preamplifier signals were recorded for time-of-flight separated neutrons and γ rays, emitted by a <sup>252</sup>Cf source. The experimental waveforms from the detectors were compared to simulated pulse shapes. In the analysis, special emphasis was given to the detection of elastically scattered neutrons, which may be an important effect to take into account in future spectrometers based on γ-ray tracking. No differences between neutron and γ-ray induced pulse shapes were found in this work.</p><p>A Monte Carlo simulation of the interactions of fast neutrons in the future 4π γ-ray spectrometer AGATA was also performed, in order to study the influence of neutrons on γ-ray tracking. It was shown that although there is a large probability of detecting neutrons in AGATA, the neutrons decrease the photo-peak efficiency of AGATA by only about 1% for each neutron emitted in coincidence with γ rays. The peak-to-background ratios in γ-ray spectra are, however, reduced to a much larger extent. The possibility of using AGATA as a neutron detector system was also investigated.</p>
243

Characterisation of the Neutron Wall and of Neutron Interactions in Germanium-Detector Systems

Ljungvall, Joa January 2005 (has links)
A Monte Carlo simulation of the Neutron Wall detector system has been performed using Geant4, in order to define optimum conditions for the detection and identification of multiple neutrons. Emphasis was put on studying the scattering of neutrons between different detectors, which is the main source of the apparent increase of the number of detected neutrons. The simulation has been compared with experimental data. The quality of neutron gated γ-ray spectra was improved for both two- and three-neutron evaporation channels. The influence of small amounts of γ rays mis-interpreted as neutrons was investigated. It was found that such γ rays dramatically reduce the quality of neutron gated γ-ray spectra. The interaction properties of fast neutrons in a closed-end coaxial and a planar high-purity germanium detector (HPGe) were studied. Digitised waveforms of HPGe preamplifier signals were recorded for time-of-flight separated neutrons and γ rays, emitted by a 252Cf source. The experimental waveforms from the detectors were compared to simulated pulse shapes. In the analysis, special emphasis was given to the detection of elastically scattered neutrons, which may be an important effect to take into account in future spectrometers based on γ-ray tracking. No differences between neutron and γ-ray induced pulse shapes were found in this work. A Monte Carlo simulation of the interactions of fast neutrons in the future 4π γ-ray spectrometer AGATA was also performed, in order to study the influence of neutrons on γ-ray tracking. It was shown that although there is a large probability of detecting neutrons in AGATA, the neutrons decrease the photo-peak efficiency of AGATA by only about 1% for each neutron emitted in coincidence with γ rays. The peak-to-background ratios in γ-ray spectra are, however, reduced to a much larger extent. The possibility of using AGATA as a neutron detector system was also investigated.
244

Upgrading the Control and Monitoring system for the TOFOR neutron time-of-flight spectrometer at JET

Valldor-Blücher, Johan January 2013 (has links)
This report describes the development and testing of the upgraded Control and Monitoring (C&amp;Mu) system for the TOFOR neutron spectrometer. TOFOR is currently performing plasma diagnostics for the JET experimental fusion reactor. The purpose of the C&amp;Mu system is to enable monitoring of the amplitude dependent time delays of TOFOR. In order to perform this monitoring function the C&amp;Mu system must comprise a pulsed light source with variable intensity and a reference time signal. In this work a reference time signal has been retrieved from a laser comprising a motorized polarizer. This has been accomplished by installing a photomultiplier tube and a beamsplitter cube. The beamsplitter cube splits the laser light into two parts and directs one part into the photomultiplier tube. The photomultiplier tube converts the light into an electrical reference time signal. A control program has been developed for the motorized polarizer, enabling the user to vary the intensity of the light over the interval from 0% to 100%. The C&amp;Mu system has been performance tested and it was found that the time resolution of the system is about 0.1ns and the time stability of the system is about 0.12ns over 27 hours. The system is more than adequate to monitor variations in time delays at TOFOR of several nanoseconds, over a full JET day. The C&amp;Mu system is ready to be installed on TOFOR.
245

3D imaging using time-correlated single photon counting

Neimert-Andersson, Thomas January 2010 (has links)
This project investigates a laser radar system. The system is based on the principles of time-correlated single photon counting, and by measuring the times-of-flight of reflected photons it can find range profiles and perform three-dimensional imaging of scenes. Because of the photon counting technique the resolution and precision that the system can achieve is very high compared to analog systems. These properties make the system interesting for many military applications. For example, the system can be used to interrogate non-cooperative targets at a safe distance in order to gather intelligence. However, signal processing is needed in order to extract the information from the data acquired by the system. This project focuses on the analysis of different signal processing methods. The Wiener filter and the Richardson-Lucy algorithm are used to deconvolve the data acquired by the photon counting system. In order to find the positions of potential targets different approaches of non-linear least squares methods are tested, as well as a more unconventional method called ESPRIT. The methods are evaluated based on their ability to resolve two targets separated by some known distance and the accuracy with which they calculate the position of a single target, as well as their robustness to noise and their computational burden. Results show that fitting a curve made of a linear combination of asymmetric super-Gaussians to the data by a method of non-linear least squares manages to accurately resolve targets separated by 1.75 cm, which is the best result of all the methods tested. The accuracy for finding the position of a single target is similar between the methods but ESPRIT has a much faster computation time.
246

Vanadium Oxide Anions Clusters: Their Abundances, Structures and Reactions with SO₂

Wyrwas, Richard Ben, Jr. 22 November 2004 (has links)
Early transition metal oxide clusters have been a focus of study for several years. The production of vanadium oxide cluster anions in a pulsed helium flow reactor provides a relatively precise way of introducing defect sites and controlling the oxidation state of the vanadium atoms. The composition of the clusters can be changed from the V2O5 stoichiometry, where the vanadium atom is in a +5 oxidation state, to more reduced stoichiometries yielding a mixture of oxidation states containing atoms in the +2 oxidation state. The subsequent addition of reactant gases such as H2O and SO2 yields very intense adsorption reactions as well as a demonstration of the robustness of particular defect free clusters. For example, the cluster has been identified as a defect free cluster where all vanadium atoms are in the +5 oxidation state and all oxygen atoms are predicted to be in the 2- state. The cluster has been shown to not adsorb SO2- while clusters in a reduced oxidation state, such as and readily adsorb one or more SO2 molecules. The adsorption process has been shown to be size dependent, with the smallest monovanadium oxide anions being the most reactive.
247

Bose-Einstein Condensation: Building the Testbeds to Study Superfluidity

Naik, Devang S. 11 September 2006 (has links)
Since Feynman's realization of using quantum systems to investigate quantum dynamics, interest in creating controllable quantum systems to simulate condensed matter phenomenon has been high. With the realization of BECs in 1995, the realization of a relatively clean testbed for simulating some of these phenomenon became a reality. My PhD research has been an exploration of the production and use of Bose-Einstein Condensates for the study of superfluidity. The first 3 years have been spent in the actual building of a Na BEC apparatus. During this time, we’ve implemented a distinct technique to trap ultra cold Na atoms, i.e. the Optically Plugged Trap. In the process, we have shown how atoms in a linear trap can show spin metastability and thus maintain a nonequilibrium state for long periods of time. In studying the interaction of ultra-cold atoms with light, we have developed a technique to measure the velocity distribution of atoms using a standing optical wave (Bragg Spectroscopy). Alongside this, we have also created optical traps for atoms in which we can change to shape of the trap itself to probe different condensed matter systems. The eventual goal being the investigation of condensed matter physics, specifically superfluidity, using ultra-cold atoms.
248

Characterization of Molecular Glycerophospholipids by Quadrupole Time-of-Flight Mass Spectrometry

Ekroos, Kim 10 November 2003 (has links) (PDF)
The physical properties of glycerophospholipids (GPLs) are not only determined by the head group (HG), but also by their fatty acid (FA) chains, which affect their distribution and function within membranes in the cell. Understanding the microheterogenity of lipid membranes on a molecular level requires qualitative and quantitative characterization of individual lipids and identification of their FA moieties. The aim of my study was to introduce the new technology of multiple precursor ion scanning (MPIS) on a QSTAR Pulsar time-of-flight mass spectrometer (QqTOF) to analyze lipids. Detailed information on fatty acid composition of individual GPL molecules could be obtained in parallel with conventional profiling of lipid classes, and this could be done by direct analysis of total lipid extracts. This method was termed Fatty Acid Scanning (FAS) and Head Group Scanning HGS, respectively. In this way the molecular GPL composition of total lipid extracts could be charted in a single analysis accurately and rapidly at a low picomole concentration level. Furthermore, combining FAS and HGS together with ion trap MS3 analysis allowed complete charting of the molecular composition of PCs, including quantification of their positional isomers, thus providing a detailed and comprehensive characterization of molecular composition of the pool of PCs. Development of the Lipid Profiler software allowed full automation and rapid processing of complex data, including identification and quantification of molecular GPLs. This approach was evaluated by preliminary applications. First, the molecular composition of PCs of total lipid extracts of MDCK cells and of human red blood cells (RBC) could accurately be charted. Significant presence of positional isomers was observed increasing the total number of individual PC species close to one hundred. Secondly, the molecular PC and SM species distribution in detergent resistant membranes (DRMs) prepared by Triton X-100 DRMs were analyzed and were found to be enriched in distinct GPLs. The distribution in PCs and SMs of Triton X-100 DRMs of RBC were compared with those of the DRMs of MDCK cells. Finally, combining the use of a 96 well plate and a robotic system demonstrated that these analyses can be automated and analyzed with high throughput. This system we termed Shotgun Lipidomics. Taken together, this mass spectrometric methodology provides rapid and detailed insight into the distribution of the molecular GPLs of membranes and membrane sub-fractions.
249

Molecular and epidemiological studies on eyes with pseudoexfoliation syndrome

Botling Taube, Amelie January 2015 (has links)
Pseudoexfoliation (PEX) syndrome is an age-related condition characterized by the production and accumulation of extracellular fibrillary material in the anterior segment of the eye. PEX predisposes for several pathological conditions, such as glaucoma and complications during and after cataract surgery. The pathogenesis of PEX is not yet fully understood. It is multifactorial with genetics and ageing as contributing factors. We aimed to study the proteome in aqueous humor (AH) in PEX in order to increase the knowledge about its pathophysiology. Therefore, we developed sampling techniques and evaluated separation methods necessary for analyzing small sample volumes. Other objectives were to study the lens capsule in eyes with PEX regarding small molecules, and to investigate the association between PEX and cataract surgery in a population-based 30-year follow-up study. Samples of AH from eyes with PEX and control eyes were collected during cataract surgery. In pooled, and individual samples, various liquid based separation techniques and high resolution mass spectrometry were utilized. For quantitation, various methods for labeling, and label free techniques were applied. Lens capsules were collected from some of the patients, and analysed by imaging mass spectrometry. A cohort of 1,471 elderly individuals underwent a comprehensive ophthalmological examination at baseline. Medical information was obtained by questionnaires, and from medical records. Incident cases of cataract surgery were identified by review of medical records. In the initial study, several techniques were explored for protein detection, and a number of proteins were identified as differentially expressed. In the individually labelled samples, changes in the proteome were observed. Eyes with PEX contained higher levels of proteins involved in inflammation, oxidative stress, and coagulation, suggesting that these mechanisms are involved in the pathogenesis in PEX. The levels of β/γ-crystallins were significantly increased in PEX, which is a novel finding. In the lens capsules from individuals with PEX, changes in the lipid composition was observed with time-of-flight secondary ion mass spectrometry. These changes remain to be elucidated. By multivariate analysis, lens opacities were the first, and PEX the second most important predictor for cataract surgery, the later accounting for a 2.38-fold increased risk for cataract surgery.
250

Entwicklung zweier Spektrometer für laserbeschleunigte Protonenstrahlen

Richter, Tom 10 October 2013 (has links) (PDF)
Durch die Fokussierung eines ultrakurzen und hochintensiven Laserpulses auf ein Festkörpertarget können Pulse von Protonen und anderen positiv geladenen Ionen mit Teilchenenergien von einigen MeV pro Nukleon erzeugt werden. Die Charakterisierung dieser Teilchenstrahlung erfordert die Identifizierung der Ionenspezies und die Bestimmung ihrer spektralen Verteilung möglichst nach jedem Puls. Im Rahmen dieser Diplomarbeit wurden zwei Spektrometer entwickelt und am DRACO-Lasersystem des Forschungszentrums Dresden implementiert. Neben der Inbetriebnahme eines Thomson-Spektrometers mit einer Mikrokanalplatte und einem Fluoreszenzschirm als Auslese erfolgte die Entwicklung eines Flugzeitspektrometers. Die Verwendung einer Mikrokanalplatte mit nur 180ps Anstiegszeit als Signalverstärker sorgt darin für eine verbesserte Energieauflösung und einen flexibleren Einsatz im Experimentierbetrieb. Ein dem Flugzeitsignal überlagertes Störsignal, welches durch die Einstreuungen eines elektromagnetischen Impulses in den Aufbau verursacht wurde, konnte erfolgreich durch die Anwendung verschiedener Filter unterdrückt werden. Als Ergebnis dieser Arbeit steht eine anwendungsbereite Diagnostik für laserbeschleunigte Protonen und Ionen zur Verfügung. / By focusing an ultra-short high-intensity laser pulse on a solid target, pulses of protons and other positive charged ions with energies of several MeV per nucleon are generated. It is necessary to identify the species of those particles and obtain their energy spectra in a single-shot regime. Within this diploma thesis two spectrometers have been developed and implemented in the DRACO-laboratory of the Forschungszentrum Dresden. Besides a Thomson spectrometer with read-out via microchannel plate and phosphor screen, a time-of-flight spectrometer was developed. The usage of a microchannel plate with 180ps rise time as a signal amplifier leads therein to a better energy resolution and a more flexible handling in experimental operation. A noise signal generated by stray pick-up of an electromagnetic pulse and superimposing the time-of-flight signal was considerably reduced by the application of different filters. As a result of this work a ready-to-use diagnostic for laser accelerated protons and ions is available.

Page generated in 0.052 seconds