• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 71
  • 37
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 121
  • 62
  • 51
  • 48
  • 27
  • 23
  • 15
  • 15
  • 15
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Effect of chlorhexidine and other antimicrobial agents on the formation and viability of oral bacterial biofilms

Pratten, Jonathan Richard January 1998 (has links)
No description available.
32

Efeito da escovação associada à dentifrício branqueador na degradação superficial e formação de biofilme em materiais cerâmicos /

Pereira, Sarina Maciel Braga. January 2007 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Marco Antonio Bottino / Banca: Karla Zanini Kantorski / Resumo: O objetivo desse trabalho foi avaliar o efeito da escovação associada a dentifrícios convencional e branqueador na rugosidade superficial, perda de massa e formação de biofilme in situ em diferentes materiais. Amostras das cerâmicas feldspáticas (VM7, VM13) e de esmalte humano foram confeccionadas em formato de disco (5mmx2mm) e submetidas às condições experimentais (n=12): a) sem escovação; b) escovação sem dentifrício; c) escovação com dentifrício convencional; d) escovação com dentifrício branqueador. A simulação da escovação foi feita em máquina simuladora. As amostras das condições b, c e d foram avaliadas, quanto à rugosidade e perda de massa, antes e após a escovação. Para o estudo in situ, 10 pacientes utilizaram um dispositivo bucal durante 8 horas. Uma amostra de cada material para cada condição foi fixada no dispositivo. Na avaliação da formação do biofilme, as amostras foram analisadas em MEV. Os dados de rugosidade, perda de massa e biofilme foram analisados estatisticamente com os testes ANOVA e Tukey. O teste de Kruskal-Wallis foi também utilizado para análise de biofilme. Os resultados demonstraram que o esmalte apresentou os maiores valores de perda de massa (1,58 mg) e rugosidade (2,39 'mü'm), independente das condições experimentais. O dentifrício branqueador causou efeito significativo na perda de massa nas cerâmicas (VM7=0,29 mg; VM13=0,35 mg). Foram observadas alterações significantes (p<0,05) na rugosidade das cerâmicas em algumas condições experimentais. Nenhuma correlação significante foi observada entre a rugosidade e biofilme. Concluiu-se que a formação de biofilme não foi influenciada pelas condições de escovação nos diferentes substratos. / Abstract: The aim of this study was to evaluate the toothbrushing effect with conventional and whitening dentifrice on the surface roughness, mass loss and early dental biofilm formation in situ in different materials. Feldspar ceramics (VM7, VM13) and human enamel samples were made in disk format (5mmx2mm) and submitted to experimental conditions (n=12): a) without toothbrushing, b) toothbrushing without dentifrice, c) toothbrushing with conventional dentifrice and d) toothbrushing with whitening dentifrice. The toothbrushing simulation was made in a simulator machine. The samples of the conditions b, c and d were evaluated by means of roughness and mass loss, before and after toothbrushing. In the in situ study, 10 patients used an oral device during 8 hours. One sample of each material for each condition was fixed in the device. For the evaluation of early dental biofilm formation, the samples were analyzed with SEM. Roughness, mass loss and biofilm data were statistically analyzed with ANOVA and Tukey tests. Kruskal-Wallis test was also used to analyze the biofilm. The enamel presented the highest mass loss (1,58 mg) and roughness (2,39'mü'm) values, independent of experimental conditions. The whitening dentifrice caused significant effect on mass loss in ceramics (VM7=0,29 mg; VM13=0,35 mg). It was observed significant (p<0,05) roughness differences in some experimental conditions. No significant correlation was observed between surface roughness and biofilm formation. It was concluded that the biofilm formation wasn't influenced by the experimental toothbrushing conditions in the differents materials. / Mestre
33

The effectiveness of the orbital motion automatic toothbrush and powered interdental stimulator as compared to the manual toothbrush & interdental stimulator a thesis submitted in partial fulfillment ... periodontics ... /

Kanouse, M. C. January 1966 (has links)
Thesis (M.S.)--University of Michigan, 1966.
34

The effectiveness of the orbital motion automatic toothbrush and powered interdental stimulator as compared to the manual toothbrush & interdental stimulator a thesis submitted in partial fulfillment ... periodontics ... /

Kanouse, M. C. January 1966 (has links)
Thesis (M.S.)--University of Michigan, 1966.
35

Efeito da escovação associada à dentifrício branqueador na degradação superficial e formação de biofilme em materiais cerâmicos

Pereira, Sarina Maciel Braga [UNESP] 11 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-11Bitstream added on 2014-06-13T18:35:16Z : No. of bitstreams: 1 pereira_smb_me_sjc.pdf: 5240229 bytes, checksum: e1ef7d2527f4ae44734b9b6873101134 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse trabalho foi avaliar o efeito da escovação associada a dentifrícios convencional e branqueador na rugosidade superficial, perda de massa e formação de biofilme in situ em diferentes materiais. Amostras das cerâmicas feldspáticas (VM7, VM13) e de esmalte humano foram confeccionadas em formato de disco (5mmx2mm) e submetidas às condições experimentais (n=12): a) sem escovação; b) escovação sem dentifrício; c) escovação com dentifrício convencional; d) escovação com dentifrício branqueador. A simulação da escovação foi feita em máquina simuladora. As amostras das condições b, c e d foram avaliadas, quanto à rugosidade e perda de massa, antes e após a escovação. Para o estudo in situ, 10 pacientes utilizaram um dispositivo bucal durante 8 horas. Uma amostra de cada material para cada condição foi fixada no dispositivo. Na avaliação da formação do biofilme, as amostras foram analisadas em MEV. Os dados de rugosidade, perda de massa e biofilme foram analisados estatisticamente com os testes ANOVA e Tukey. O teste de Kruskal-Wallis foi também utilizado para análise de biofilme. Os resultados demonstraram que o esmalte apresentou os maiores valores de perda de massa (1,58 mg) e rugosidade (2,39 'mü'm), independente das condições experimentais. O dentifrício branqueador causou efeito significativo na perda de massa nas cerâmicas (VM7=0,29 mg; VM13=0,35 mg). Foram observadas alterações significantes (p<0,05) na rugosidade das cerâmicas em algumas condições experimentais. Nenhuma correlação significante foi observada entre a rugosidade e biofilme. Concluiu-se que a formação de biofilme não foi influenciada pelas condições de escovação nos diferentes substratos. / The aim of this study was to evaluate the toothbrushing effect with conventional and whitening dentifrice on the surface roughness, mass loss and early dental biofilm formation in situ in different materials. Feldspar ceramics (VM7, VM13) and human enamel samples were made in disk format (5mmx2mm) and submitted to experimental conditions (n=12): a) without toothbrushing, b) toothbrushing without dentifrice, c) toothbrushing with conventional dentifrice and d) toothbrushing with whitening dentifrice. The toothbrushing simulation was made in a simulator machine. The samples of the conditions b, c and d were evaluated by means of roughness and mass loss, before and after toothbrushing. In the in situ study, 10 patients used an oral device during 8 hours. One sample of each material for each condition was fixed in the device. For the evaluation of early dental biofilm formation, the samples were analyzed with SEM. Roughness, mass loss and biofilm data were statistically analyzed with ANOVA and Tukey tests. Kruskal-Wallis test was also used to analyze the biofilm. The enamel presented the highest mass loss (1,58 mg) and roughness (2,39'mü'm) values, independent of experimental conditions. The whitening dentifrice caused significant effect on mass loss in ceramics (VM7=0,29 mg; VM13=0,35 mg). It was observed significant (p<0,05) roughness differences in some experimental conditions. No significant correlation was observed between surface roughness and biofilm formation. It was concluded that the biofilm formation wasn't influenced by the experimental toothbrushing conditions in the differents materials.
36

AvaliaÃÃo in vitro do efeito da escovaÃÃo com dentifrÃcios clareadores sobre a superfÃcie dentinÃria / In vitro evaluation of the toothbrushing effect with whitening toothpaste abrasion on root dentine

Gustavo Henrique Apolinario Vieira 30 March 2012 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / A escovaÃÃo tem um papel importante na etiologia da hipersensibilidade dentinÃria. AbrasÃo pode estar relacionada a abrasivos contidos nos dentifrÃcios. O objetivo deste estudo foi comparar por perfilometria mecÃnica o efeito da abrasÃo da escovaÃÃo com dentifrÃcios clareadores e convencionais na dentina radicular. Noventa espÃcimes de dentina (4 x 4 x 2mm) foram aleatoriamente divididos em cinco grupos experimentais (n=18) de acordo com os dentifrÃcios: trÃs clareadores (W1, W2, e W3) e dois convencionais (C1 e C2), produzidos por dois fabricantes distintos. Utilizando uma mÃquina de escovaÃÃo, cada espÃcime foi escovado com carga constante de 300g por 2500 ciclos (4,5 ciclos por segundo). Os dentifrÃcios foram diluÃdos na proporÃÃo de 1:3 em peso (dentifrÃcio/saliva artificial). A ponta diamantada do perfilÃmetro moveu-se em velocidade constante de 0,05mm/s com forca de 0,7mN. O valor mÃdio das leituras da abrasÃo da escovaÃÃo (&#956;m; mÃdia  desvio padrÃo) foi obtido de cinco leituras consecutivas em cada espÃcime: W1 = 8,86  1,58, W2 = 8,27  2,39, W3 = 7,59  1,04, C1 = 2,94  1,29 C2 = 2,89  1,05. Houve diferenÃa estatisticamente significante entre os grupos (ANOVA - p<0.0001). O teste de Tukey para mÃltiplas comparaÃÃes mostrou diferenÃas entre todos os dentÃfricios clareadores e os convencionais, mas nÃo entre os clareadores e os convencionais entre si. DentifrÃcios clareadores podem causar mais abrasÃo na dentina do que os convencionais. / Toothbrushing abrasion has an important role in the etiology of dentine hypersensitivity. The abrasion may be related to the abrasivity of the toothpaste. The aim of this study was to compare by mechanical profilometry the effect of toothbrushing abrasion with whitening and regular toothpastes on root dentine. Ninety dentine specimens (4x4x2 mm) were randomly divided into five experimental groups (n=18) according to the toothpaste: three whitening (W1, W2 and W3) and two regular toothpastes (C1 and C2), produced by two different manufacturers. Using a brushing machine, each specimen was brushed with constant load of 300g for 2500 cycles (4.5 cycles/second). The toothpastes were diluted at a ratio of 1:3 w/w (dentifrice/distilled water). The brush diamond tip of the profilometer moved at a constant speed of 0.05 mm/s with a force of 0.7 mN. The average reading value of brushing abrasion (&#956;m; mean  standard deviation) was obtained from five consecutive measurements of each specimen: W1 = 8.86  1.58, W2 = 8.27  2.39, W3 = 7.59  1.04, R1 = 2.94  1.29 and R2 = 2.89  1.05. There was a significant difference between groups (ANOVA - p<0.0001). Post-hoc Tukey test for multiple comparison showed differences between all the whitening toothpastes and the regular ones, but not among the whitening or the regular against each other. Whitening toothpastes can cause more dentine abrasion than the regular ones.
37

Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing test

Marques, Vinícius Rizzo 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (&#x3B1;=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((&#x3B1;= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.
38

Efeito de diferentes métodos de higienização sobre a rugosidade superficial de materiais restauradores CAD/CAM /

Castro, Camila Lebre de January 2019 (has links)
Orientador: Edson Alves de Campos / Resumo: A cerâmica é uma opção que preenche as exigências estéticas, biológicas, mecânicas e funcionais de um material restaurador. O sistema CAD/CAM empregado na Odontologia permite confeccionar restaurações indiretas, em um curto período de tempo, cimentá-las na mesma sessão clínica, sem a intermediação do laboratório de prótese. Qualquer material restaurador está sujeito a desgastes por ação da mastigação e a escovação diária. Protocolos de higienização profissional devem ser estabelecidos de maneira a não afetarem a rugosidade superficial das restaurações. O objetivo deste estudo foi avaliar a rugosidade superficial (Ra) de materiais restauradores CAD/CAM após diferentes métodos de higienização. Trata-se de um estudo in vitro que utilizou espécimes (n=144) dos seguintes materiais: Cerâmica Feldspática (Cerec Blocs, Dentsply Sirona); Cerâmica Feldspática reforçada por Leucita (IPS Empress CAD, Ivoclar Vivadent); Cerâmica Di-silicato de lítio (IPS e-max CAD, Ivoclar Vivadent) e Compósito nano híbrido (Grandio Blocs, Voco), sendo que dois materiais, Cerâmica Feldspática e Cerâmica Feldspática reforçada por Leucita foram avaliados com e sem glaze. Os espécimes foram submetidos a três diferentes métodos de higienização (escovação simulada; jato de bicarbonato de sódio e profilaxia com taça de borracha e pasta profilática). A rugosidade superficial foi mensurada antes e após os diferentes métodos de higienização por meio do rugosímetro de contato. A análise de variância foi feita para ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dental ceramic has been a restorative material option that may provide the aesthetic, biological, mechanical and functional requirements. CAD/CAM (computer aided design/computer aided manufacturing) system used in Dentistry allows to perform indirect restorations in a short period of time and proceed the cementation in the same clinical session without the intermediation of prosthesis laboratory. However, any restorative material can wear due to chewing and daily toothbrushing action. Thus, hygiene protocols should be stated in order to not affect the surface roughness of restorations. This study aimed to evaluate the surface roughness (Ra) of CAD/CAM restorative materials after different hygiene protocols. This in vitro study used the following materials (n=144): Feldspathic ceramic (Cerec Blocs, Dentsply Sirona); Leucite-reinforced feldspathic ceramic (IPS Empress CAD, Ivoclar Vivadent); Lithium disilicate ceramic (IPS e-max CAD, Ivoclar Vivadent) and Nanohybrid resin-based composite (Grandio Blocs, Voco). For Feldspathic ceramic and Leucite-reinforced feldspathic ceramic it was performed the evaluations with and without glaze. The samples were submitted to three different hygiene protocols (simulated brushing, sodium bicarbonate jet and prophylaxis with rubber cup and prophylactic paste). Surface roughness was measured before and after the hygiene protocols by a contact rugosimeter. ANOVA test was applied to evaluate the initial roughness among materials, followed by Games... (Complete abstract click electronic access below) / Mestre
39

AvaliaÃÃo da alteraÃÃo estrutural do esmalte dentÃrio promovida por erosÃo/abrasÃo / Assessment of structural alteration on dental enamel promoted by erosion / abrasion

Vanara FlorÃncio Passos 06 March 2009 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / O desgaste dentÃrio à a perda nÃo cariosa de tecido dentÃrio caracterizado por uma etiologia multifatorial tendo como principal fator a interaÃÃo entre erosÃo ocasionada por Ãcidos e forÃas abrasivas intra-orais. Essa dissertaÃÃo à constituÃda por dois artigos que objetivam, respectivamente: (1) revisar criticamente a literatura disponÃvel sobre as tÃcnicas de anÃlises de alteraÃÃes micromorfolÃgicas da estrutura dentÃria submetida a processos de erosÃo e/ou abrasÃo; (2) avaliar o efeito do NaF e MFP presentes em dentifrÃcios comercializados na prevenÃÃo da desmineralizaÃÃo da estrutura dentÃria por processos erosivos ou erosivos e abrasivos. No artigo 1, a literatura cientÃfica pertinente ao assunto foi obtida usando a base de dados nacionais e internacionais e busca manual de referÃncias citadas em artigos cientÃficos. No artigo 2, foi realizado um estudo in situ, randomizado, duplo-cego, cruzado, boca-dividida, em trÃs fases de 5 dias cada, com a participaÃÃo de 15 voluntÃrios, que utilizaram dispositivos palatinos, contendo 4 blocos de esmalte dental humano tratados com diferentes dentifrÃcios: controle (11,2 ppm F, silica), MFP (1450 ppm F, silica) e NaF (1450 ppm F, silica). Os blocos foram submetidos à erosÃo por imersÃo em bebida do tipo cola (Coca-ColaÂ) por 60 s, 4 vezes ao dia, em horÃrios prÃ-determinados. Em seguida, os voluntÃrios escovaram seus dentes por 25 segundos e, com o dispositivo na boca, bochecharam o dentifrÃcio/saliva por 60 segundos, sendo posteriormente um lado do dispositivo (2 blocos) escovado com uma pequena porÃÃo de dentifrÃcio por 40 movimentos de vai-e-vem. As alteraÃÃes no esmalte foram avaliadas por testes de microdureza e por microscopia eletrÃnica de varredura. Os dados obtidos foram testados usando ANOVA (p < 0,05). A anÃlise crÃtica do artigo 1 mostrou que a literatura apresenta diferentes mÃtodos para anÃlise de desgaste dentÃrio, variando de tÃcnicas bem estabelecidas a tÃcnicas de uso recente, sendo seus conhecimentos necessÃrios para o desenvolvimento de estudos futuros. Os resultados do artigo 2 demonstraram que nÃo houve diferenÃa no efeito da remineralizaÃÃo dos dentifrÃcios fluoretados nas condiÃÃes de erosÃo e erosÃo associada à abrasÃo em relaÃÃo ao grupo controle (p > 0,05). Contudo, os dados de dureza referentes à condiÃÃo (erosÃo ou erosÃo + abrasÃo) apresentaram-se diferentes estatisticamente (p < 0.0001). Conclui-se que o conhecimento sobre tÃcnicas de anÃlise acerca do desgaste dentÃrio à indispensÃvel para a sua determinaÃÃo e que à premente a realizaÃÃo de mais estudos para avaliaÃÃo do efeito do flÃor, na forma de NaF ou MFP, presente em dentifrÃcios comercializados utilizando tÃcnicas complementares que permitam a mediÃÃo do desgaste. / Dental wear is the non-carious loss of dental hard tissue, characterized by a multifactorial etiology with the main factor the interaction between erosion caused by acids from diet or endogenous and abrasives forces intra-oral. This dissertation consisting of two articles, which aim, respectively: (1) to critically review the available literature about the techniques of analysis of micromorphological changes in structure dental subject to erosion and/or abrasion, (2) to evaluate the effect of NaF and MFP in dentifrices available in market in the prevention of demineralization of tooth structure by erosive or erosive and abrasive process. In study 1, the scientific literature to the issue was searched using base of data nationals and internationals and manual tracing of references cited in scientific papers. In study 2, a in situ study, randomized, double-blind, crossover, slipt-mouth was conducted in three phases of 5 days each, with the participation of 15 volunteers who used palatal devices, containing 4 blocks of human tooth enamel treated with different dentifrices: control (11,2 ppm F, silica), MFP (1450 ppm F, silica) and NaF (1450 ppm F, silica). The slabs were subjected to erosion by immersion in a cola drink (Coca-ColaÂ) for 60 s, 4 times a day, at predetermined times. Then, the volunteers brushed their teeth, for 25 seconds and, with the device in the mouth, swished the dentifrice/saliva slurry for 60 seconds, after on side of appliance (2 blocks) was brushed with a small portion of the dentifrice by 40 brushing strokes. The enamel changes were evaluated for microhardness test and scanning electron microscopy. Data scores were submitted to ANOVA (p < 0,05). The critical review presented in study 1 showed which the literature presents different methods for analysis of dental wear, ranging from techniques well-established to techniques of recent use, therefore their expertise is needed for the development of future studies. The results of study 2 demonstrated that there was no differences in remineralization effect of fluoride dentifrices in the condition of erosion and erosion plus abrasion in relation of control group (p > 0,05). However, the harness data concerning to condition (erosion or erosion + abrasion) showed different statistically (p < 0.0001). The results of these studies indicate the knowledge about techniques of analysis of dental wear is essential for its determination. Moreover, it is imperative the realization of more studies to evaluate the fluoride effect in form of NaF or MFP, present in dentifrices available in the market using complementary techniques that allow the measurement of wear.
40

Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing test

Vinícius Rizzo Marques 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (&#x3B1;=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((&#x3B1;= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.

Page generated in 0.0631 seconds