• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 18
  • 18
  • 11
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Grade 300 Prestressing Strand and the Effect of Vertical Casting Position

Carroll, James Christopher 01 September 2009 (has links)
The purpose of this study was to investigate the influence an increase in strand strength and the effect the as-cast vertical location had on transfer length, development length, and flexural strength and to resolve the discrepancies regarding the definition of the top-bar/strand effect. Two types of test specimens were fabricated and tested investigating each respective item. The increase in strand strength was found to influence transfer length, development length, and flexural strength, while the as-cast vertical location was only found to influence transfer length, and in turn development length. Contrary to the historical definition, the top-bar/strand effect was found to be more dependent on the amount of concrete cast above the strand than the amount below it, with transfer lengths showing a steady increase with a decrease in the amount of concrete cast above the strand. As a result of the findings of this study, a new transfer length equation was proposed and a previously proposed flexural bond length equation was recommended for use in lieu of the current code provisions. The current equations for flexural strength were found to give adequate estimates for flexural strength, although a decrease in ductility was noted. / Ph. D.
12

Investigation of Transfer Length, Development Length, Flexural Strength and Prestress Loss Trend in Fully Bonded High Strength Lightweight Prestressed Girders

Nassar, Adil J. 26 June 2002 (has links)
Encouraged by the performance of high performance normal weight composite girders, Virginia Department of Transportation has sought to exploit the use of high strength lightweight composite concrete (HSLWC) girders to achieve economies brought about by the reduction of dead loads in bridges. Transfer Length measurements conducted on two AASHTO Type IV HSLWC prestressed girders, resulted in an average transfer length of 17 inches, well below the AASHTO and ACI guidance. Two girders composed of HSLWC AASHTO Type II girders and a 48" x 8" normal weight 4000-psi concrete deck were produced. The HSLWC Type II girders were cast of concretes with a compressive strength of 6380 psi and unit weight of 114 pcf. Full scale testing of the girders was conducted to evaluate development length and flexural strength in HSLWC composite girders. Embedment lengths of five, six and eight feet were evaluated. Tests indicated a development length of about 72 inches, marginally below the ACI and AASHTO stipulation. Four of eight strands in the girders showed general bond failure nevertheless, the tested girders exceeded their theoretical flexural capacity by 24 to 30 percent. A third composite girder was cast of a high strength normal weight concrete (HSNWC) Type II girder, and topped with a 48" x 8" normal weight 4000-psi concrete deck. This girder was intended as a control specimen to contrast its test results with the HSLWC composite girders. The targeted compressive strength of both the HSLWC and HSNWC AASHTO beams was 8000 psi. The compressive strength of the HSNWC mixture, however, was about 8990 psi compared to 6380 psi for the HSLWC mixture. Prestress losses in HSLWC AASHTO Type IV girders monitored over a nine-month period were found to be less than those calculated using the ACI and PCI models. Furthermore, the ACI model indicated that the effective prestressess retained in the HSLWC girders in 30 year's time are greater than 50% of the specified tensile strength of the strands. / Master of Science
13

Concrete fluidity effects on bond of prestressed tendons for lightweight bridge girders

Perkins, Jake January 1900 (has links)
Master of Science / Department of Civil Engineering / Robert J. Peterman / With limited research being conducted solely on lightweight concrete prestressed bond and current development-length equations based on tests performed on normal-weight members, more investigation on lightweight concrete prestress bond is necessary. Additionally, the effects of water-reducing agents on normal-weight and lightweight concrete need further exploration. The aim of this study was to examine these areas using two locally available lightweight aggregates from Kansas and one from North Carolina to determine if lightweight prestressed concrete bridge girders are a useful alternative for the Kansas Department of Transportation. The lightweight concrete mixes developed were capable of attaining 5000 psi compressive strength in 16 hours and 7000 psi in 28 days. During the large block pull-out test, the average maximum force at pull-out and first observable slip was higher for the block cast with a three inch slump then the companion specimen poured at a nine-inch slump. During flexural testing, the two beams not reaching nominal moment capacity, KC-9 and STA-9, failed in compression without strand end slip. The moment capacity was considerably greater for three-inch slump members than the companion specimen placed with nine-inch slump concrete.
14

Bond and Material Properties of Grade 270 and Grade 300 Prestressing Strands

Loflin, Bryan 28 July 2008 (has links)
The first objective of this thesis was to determine the material properties of grade 270 and grade 300 prestressing strand of various sizes. Tension tests were performed on each type of strand. The data from these tests was used to determine modulus of elasticity, yield stress, ultimate stress, and ultimate elongation for each strand. The yield stresses and ultimate stresses for many of the strands did not meet the requirements found in ASTM A416. The ultimate elongation results far exceeded the requirements and the measured elastic moduli were near the modulus recommended by AASHTO LRFD. A secondary objective from the tension tests was to evaluate a gripping method which used aluminum tubing to cushion the strands against notching. The grips performed very well. Most of the strand breaks did not occur in the grips and when a strand did break in the grips, the failure occurred after significant post-yield elongation. The second objective was to evaluate the bond properties of grade 270 and grade 300 prestressing strands. The North American Strand Producers (NASP) Bond Test and Large Block Pullout Test (LBPT) were performed on six different strand grade and strand size combinations. Both of the tests are simple pullout tests on untensioned strand. The results for each strand type were compared to one another as well as to measured transfer and development lengths from beams using the strand from the same reel. All of the strands showed sufficient bond in the beams, but one strand type did fail both the NASP Test and the LBPT. Both pullout tests were acceptable methods to evaluate strand surface condition and the benchmarks set for 0.5 in. diameter regular strand were conservative for the strands used in this thesis. Little difference was evident in the bond performance of grade 270 and grade 300 prestressing strand. / Master of Science
15

Niobium Ohmic Contacts for Cryogenic Indium Phosphide High-Electron-Mobility Transistors / Niob-baserade Ohmska Kontakter för Kryogena Indiumfosfid Högelektronmobilitetstransistorer

Bendrot, Linnéa January 2022 (has links)
Ohmic contacts are crucial components in semiconductor devices such as transistors and diodes, and lowering their contact resistance is an important factor in device performance enhancement. This is especially important for low-noise amplifiers (LNAs) where device noise temperature decreases both directly and indirectly with decreasing contact resistance. This becomes relevant in quantum computers operated at cryogenic temperatures as LNAs constitutes the 4 K quantum bit (qubit) readout signal amplification chain. The goal of this project is to investigated the superconducting element niobium (Nb) as contact material for indium phosphide (InP) high-electron-mobility transistors (HEMTs), being the active component in cryogenic high-frequency LNAs. For contact and barrier resistance determination, test structures were fabricated and utilized according to the transfer length method(TLM) and the recess TLM respectively. Measurements were performed in room temperature as well as in cryogenic temperatures below and above Nb’s bulk transition temperature of 9.25 K. The results show low-resistance Nb-based ohmic contacts for n-In0.65Ga0.35As, with the non-alloyed Nb(50 nm)/Au(100 nm) stack yielding a room temperature contact resistivity of (9.4 ± 0.5) × 10−8 Ωcm2. For all contacts the contact resistivity increased moving to cryogenic temperatures, as expected when electron occupation of high-energy states decreases. At cryogenic temperatures nosuperconducting transition was observed, attributed to the Nb layer thickness being roughly equal to its coherence length. Considering the effective barrier resistance, the Ni/Ge/Au/Nb/Au alloyed contact had the lowest room temperature resistance, reporting 143 Ω µm. In cryogenic temperatures the effective barrier resistance unexpectedly decreased in all contacts. The Nb/Au contact showed the best cryogenic performance, with a barrier resistance of 28 − 37 Ω µm. This indicates great potential for non-alloyed Nb/Au contacts in cryogenic InP HEMTs. / Alla halvledarkomponenter, som dioder och transistorer, har ohmska kontakter. Att sänka kontaktresistansen hos de ohmska kontakterna är ett sätt att höja prestandan hos en komponent. Särskilt gäller detta för lågbrusförstärkare, som har en brustemperatur som minskar både direkt och indirekt med avtagande kontaktresistans. För kvantdatorer som måste kylas till kryogena temperaturer för att fungera är detta relevant eftersom förstärkningen av utläsningssignalen från kvantbitar sker via lågbrusförstärkare vid 4 K. Målet för detta examensprojekt är att undersöka ohmska kontakter baserade på det supraledande materialet niobium (Nb) i indiumfosfidbaserade högelektronmobilitetstransistorer, som är den aktivakomponenten i kryogena högfrekvens-lågbrusförstärkare. För bestämning av kontaktoch barriärresistans producerades teststrukturer enligt Transfer Length-metoden (TLM) respektive etsad TLM. Mätningar genomfördes i rumstemperatur samt vid kryogena temperaturer både över och under niobiumets kritiska temperatur på 9.25 K. Resultatet visar låg kontaktresistans för Nb-baserade ohmska kontakter på n-In0.65Ga0.35As. Den icke-legerade Nb(50 nm)/Au(100 nm)-kontakten hade en kontaktresistivitet på (9.4 ± 0.5) × 10−8 Ωcm2 . Vid kryogena temperaturer ökade kontaktresistansen för samtliga Nb-baserade kontakter, vilket är förväntat då färre elektroner fyller högenergitillstånd. Inget supraledande tillstånd observerades vid kryogena temperaturer, vilket kan förklaras av att tjockleken på niobiumlagret var ungefär lika med dess koherenslängd. Lägst barriärresistans vid rumstemperatur hade den legerade Ni/Ge/Au/Nb/Au-kontakten, med ett värde på 143 Ω µm. Vid kryogena temperaturer skedde en oväntad minskning hos barriärsresistansen hos samtliga kontakter, där den lägst barriärsresistans uppmättes på den icke-legerade Nb/Au-kontakten, 28 − 37 Ω µm. Slutsatsen som dras är att det finns stor potential för användning av icke-legerade Nb/Au-kontakter för kryogena lågbrusförstärkare baserade på indiumfosfid.
16

Carbon based nanomaterials as transparent conductive electrodes

Reiter, Fernando 19 May 2011 (has links)
Optically transparent carbon based nanomaterials including graphene and carbon nanotubes(CNTs) are promising candidates as transparent conductive electrodes due to their high electrical conductivity coupled with high optical transparency, can be flexed several times with minimal deterioration in their electronic properties, and do not require costly high vacuum processing conditions. CNTs are easily solution processed through the use of surfactants sodium dodecyl sulfate(SDS) and sodium cholate(SC). Allowing CNTs to be deposited onto transparent substrates through vacuum filtration, ultrasonic spray coating, dip coating, spin coating, and inkjet printing. However, surfactants are electrically insulating, limit chemical doping, and increase optical absorption thereby decreasing overall performance of electrodes. Surfactants can be removed through nitric acid treatment and annealing in an inert environment (e.g. argon). In this thesis, the impact of surfactant removal on electrode performance was investigated. Nitric acid treatment has been shown to p-dope CNTs and remove the surfactant SDS. However, nitric acid p-doping is naturally dedoped with exposure to air, does not completely remove the surfactant SC, and has been shown to damage CNTs by creating defect sites. Annealing at temperatures up to 1000°C is advantageous in that it removes insulating surfactants. However, annealing may also remove surface functional groups that dope CNTs. Therefore, there are competing effects when annealing CNT electrodes. The impacts on electrode performance were investigated through the use of conductive-tip atomic force microscopy, sheet resistance, and transmittance measurements. In this thesis, the potential of graphene CNT composite electrodes as high performing transparent electrodes was investigated. As-made and annealed graphene oxide CNT composites electrodes were studied. Finally, a chemical vapor deposition grown graphene CNT composite electrode was also studied.
17

Elektrische Charakterisierung PLD-gewachsener Zinkoxid-Nanodrähte

Zimmermann, Gregor 14 October 2010 (has links) (PDF)
Die vorliegende Arbeit beschäftigt sich mit der elektrischen Charakterisierung von Zinkoxid-Nanodrähten, die mittels gepulster Laserablation (PLD) hergestellt wurden. Ausgehend von den so generierten ZnO-Nanodraht-Ensembles werden Methoden zu deren elektrischer Untersuchung diskutiert und auf praktische Anwendbarkeit hin verglichen. Die entwickelten Methoden werden auf Ensembles von auf n-leitenden ZnO- und ZnO:Ga-Dünnschichten aufgewachsenen Phosphor-dotierten ZnO-Nanodrähten angewendet. Deren reproduzierbares, in Strom–Spannungs- (I–U-) Kennlinien beobachtetes diodenartiges Verhalten wird genauer beleuchtet. Im Zusammenhang mit der elektrischen Charakterisierung einzelner ZnO-Nano-drähte werden experimentelle Methoden zur Vereinzelung und zur Kontaktierung der vereinzelten ZnO-Nanodrähte diskutiert. Dabei werden sowohl etablierte Methoden wie Elektronenstrahllithographie (EBL) als auch neue Techniken wie elektronen- und ionenstrahlinduzierte Deposition (EBID/IBID) und Strom–Spannungs-Rastersondenmikroskopie (I-AFM) behandelt und ihre Eignung für eingehende elektrische Untersuchungen und reproduzierbare Messungen analysiert. Die geeignetsten Methoden werden schließlich eingesetzt, um spezifischen Widerstand sowie Ladungsträgermobilität und -dichte sowohl in nominell undotierten als auch in Aluminium-dotierten ZnO-Nanodrähten zu untersuchen und zu vergleichen. In der Ableitung der physikalischen Materialparameter aus den Messdaten wird dabei besonderes Augenmerk auf die Einbeziehung der geometrischen Besonderheiten der Nanodrähte gegenüber Volumenmaterial- und Dünnschichtproben gelegt. Im Zuge dessen wird unter anderem ein Modell für den elektrischen Widerstand in Nanodrähten mit ihrer Länge nach veränderlichem Querschnitt abgeleitet.
18

Elektrische Charakterisierung PLD-gewachsener Zinkoxid-Nanodrähte

Zimmermann, Gregor 17 August 2010 (has links)
Die vorliegende Arbeit beschäftigt sich mit der elektrischen Charakterisierung von Zinkoxid-Nanodrähten, die mittels gepulster Laserablation (PLD) hergestellt wurden. Ausgehend von den so generierten ZnO-Nanodraht-Ensembles werden Methoden zu deren elektrischer Untersuchung diskutiert und auf praktische Anwendbarkeit hin verglichen. Die entwickelten Methoden werden auf Ensembles von auf n-leitenden ZnO- und ZnO:Ga-Dünnschichten aufgewachsenen Phosphor-dotierten ZnO-Nanodrähten angewendet. Deren reproduzierbares, in Strom–Spannungs- (I–U-) Kennlinien beobachtetes diodenartiges Verhalten wird genauer beleuchtet. Im Zusammenhang mit der elektrischen Charakterisierung einzelner ZnO-Nano-drähte werden experimentelle Methoden zur Vereinzelung und zur Kontaktierung der vereinzelten ZnO-Nanodrähte diskutiert. Dabei werden sowohl etablierte Methoden wie Elektronenstrahllithographie (EBL) als auch neue Techniken wie elektronen- und ionenstrahlinduzierte Deposition (EBID/IBID) und Strom–Spannungs-Rastersondenmikroskopie (I-AFM) behandelt und ihre Eignung für eingehende elektrische Untersuchungen und reproduzierbare Messungen analysiert. Die geeignetsten Methoden werden schließlich eingesetzt, um spezifischen Widerstand sowie Ladungsträgermobilität und -dichte sowohl in nominell undotierten als auch in Aluminium-dotierten ZnO-Nanodrähten zu untersuchen und zu vergleichen. In der Ableitung der physikalischen Materialparameter aus den Messdaten wird dabei besonderes Augenmerk auf die Einbeziehung der geometrischen Besonderheiten der Nanodrähte gegenüber Volumenmaterial- und Dünnschichtproben gelegt. Im Zuge dessen wird unter anderem ein Modell für den elektrischen Widerstand in Nanodrähten mit ihrer Länge nach veränderlichem Querschnitt abgeleitet.

Page generated in 1.76 seconds