• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • Tagged with
  • 56
  • 56
  • 50
  • 43
  • 17
  • 16
  • 15
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da estabilidade, por meio da análise da frequência de ressonância (RFA), de implantes colocados na maxila posterior variando somente o tratamento de superfície: ensaio clínico randomizado / Stability evaluation, through resonance frequency analysis (RFA), of implants placed in the posterior maxilla varying only the surface treatments: randomized clinical trial

Novellino, Marcelo Michele 03 May 2018 (has links)
Contexto: Modificações químicas da superfície dos implantes dentários com o objetivo de aumentar a molhabilidade resultam em uma osseointegração mais rápida e melhor. Objetivo: O objetivo deste estudo foi avaliar o quociente de estabilidade do implante (ISQ) (implant stability quotient) de implantes com geometria idêntica, mas com tratamentos de superfície diferentes: jateamento de areia e ataque ácido (SAE) e a mesma superfície com uma modificação química para aumento da hidrofilia, dentro das primeiras 16 semanas de cicatrização. Materiais e Método: neste estudo clínico randomizado um total de 64 implantes (32 SAE - Grupo Controle e 32 SAE modificado - Grupo Teste) com o mesmo desenho geométrico, comprimento e diâmetro (cônico e compressivo, 4,3x10 mm) foram colocados na maxila posterior de 21 pacientes parcialmente desdentados. Os valores de ISQ foram coletados no pós - cirúrgico imediato (T0), com 1 semana (T1), 2 (T2), 3 (T3), 5 ( T4), 8 (T5), 12 (T6) e 16 semanas (T7). Os resultados foram comparados por meio do ANOVA de medidas repetidas. Resultados: O grupo teste apresentou valores de ISQ mais altos que o grupo controle (ANOVA - p<0,01) a partir da 5a semana. Quando comparados os grupos em relação ao tempo necessário para se atingir o ISQ >= 70 como uma referência, houve uma diferença estatisticamente significante (p<0,01) e um Hazard Ratio de 2,24 (IC 1,62-3,11). No acompanhamento de um ano um paciente com 2 implantes abandonou a pesquisa, e estes não puderam mais ser avaliados. A taxa de sobrevida de ambos grupos foi de 100% após um ano de acompanhamento. Conclusão: O presente estudo sugere que implantes com superfície hidrofílica osseointegram mais rápido que implantes com superfície SAE convencional. O ganho de estabilidade do grupo teste foi 2,24 vezes mais rápido que do grupo controle após 5 semanas de avaliação em leitos na maxila posterior. / Background: Chemical modifications of dental implant surface, to improve the wettability, results in a faster and better osseointegration. Purpose: The aim of this study was to evaluate the implant stability quotient (ISQ) of implants with the same design, treated with two different surfaces: Sandblasted Acid-Etched (SAE) and hydrophilic SAE, within the initial 16 weeks of healing. Materials and Method: For this RCT a total of 64 implants (32 SAE - Control Group and 32 modified SAE - Test Group) with the same design, length and diameter (conical and compressive, 4.3x10 mm) were inserted in the posterior maxillae of 21 patients partially edentulous. The ISQ values were collected at the post-surgery (T0), 1-week (T1), 2-weeks (T2), 3- weeks (T3), 5-weeks (T4), 8-weeks (T5), 12-weeks (T6) and 16-weeks (T7). The statistic test was ANOVA. Results: Test group presented ISQ values higher than the Control group (ANOVA - p<0.01) from 5th week. When comparing groups regarding the amount of time required to achieve ISQ >= 70 as a reference, there was a statistically significant difference (p <0.01), and a HR (Hazard Ratio) of 2.24 (CI 1.62- 3.11). At the one-year follow up, there was a drop out of one patient and two implants were no longer evaluated. Survival rate for both groups was of 100% after one year of follow up. Conclusion: The current study suggests that implants with hydrophilic surface (modified SAE) integrates faster than implants with SAE surface. Stability gain of the tested group was 2.24 times faster than the control group after five weeks of evaluation at the posterior region of maxillae.
42

Osteogênese in vitro sobre vitrocerâmica 100% cristalina e altamente bioativa (Biosilicato®): efeitos do condicionamento de superfície e dos produtos de dissolução iônica / In vitro osteogenesis on a highly bioactive glass ceramic (Biosilicate®): effects of surface conditioning and of its ionic dissolution products

Raucci, Larissa Moreira Spinola de Castro 29 May 2009 (has links)
O objetivo deste estudo foi avaliar o efeito do condicionamento de superfície de uma vitrocerâmica 100% cristalina e altamente bioativa (Biosilicato®) e de seus produtos de dissolução iônica sobre diferentes parâmetros do desenvolvimento do fenótipo osteogênico in vitro. Previamente ao plaqueamento de células osteogênicas de calvárias de ratos, discos de Biosilicato® foram condicionados, por 3 dias, em meio de cultura suplementado, com ou sem soro fetal bovino a 10%. Células osteogênicas expostas aos produtos de dissolução iônica do Biosilicato® foram também cultivadas sobre lamínulas de vidro bioinerte. Discos de Biosilicato e lamínulas de vidro foram utilizados como controles. Os resultados mostraram que o tratamento de superfície de Biosilicato® aumenta expressivamente a concentração de silício e cálcio no meio de cultura. Em 1, 3 e 7 dias, foram determinados os maiores valores de viabilidade celular em superfícies de Biosilicato® condicionado, enquanto que entre os grupos de lamínulas de vidro, observou-se menor viabilidade em culturas expostas aos produtos de dissolução iônica do Biosilicato®. Em 3 dias, células sobre todas as superfícies de Biosilicato® apresentavam-se menos espraiadas quando comparadas àquelas sobre lamínulas de vidro; neste período, a topografia das superfícies dos grupos de Biosilicato® caracterizava-se por rede de cavidades na submicro e nanoescala, enquanto que a lamínula apresentava superfície plana. Alterações no padrão de marcação das proteínas citoesqueléticas actina, vimentina, tubulina e vinculina, da subunidade de integrina &alpha;5 e da fibronectina eram observadas apenas em células crescidas sobre as superfícies de Biosilicato®. Ao final da fase proliferativa (7 dias), foram observados maiores níveis relativos de expressão de RNA mensageiro para Runx2, sialoproteína óssea (BSP) e fosfatase alcalina (ALP) em culturas crescidas sobre superfícies condicionadas de Biosilicato®; a exposição aos produtos de dissolução iônica aumentou a expressão de Runx2 e ALP nos grupos de lamínula de vidro. Em 14 dias, culturas sobre Biosilicato® condicionado em meio de cultura com soro exibiam áreas mais extensas de mineralização. Os resultados deste estudo mostraram que o condicionamento de superfícies de Biosilicato® previamente ao plaqueamento celular favorece aspectos da interação célula-substrato, promovendo maior viabilidade celular e aumentando e/ou acelerando o desenvolvimento do fenótipo osteogênico in vitro. A exposição aos produtos de dissolução iônica do Biosilicato® inibe a progressão de culturas osteogênicas sobre lamínulas de vidro bioinerte, apesar de aumentar a expressão de marcadores osteoblásticos. / The aim of the present study was to evaluate the effect of surface conditioning of a highly bioactive, fully crystalline glass-ceramic in the Na2O-CaO-SiO2-P2O5 system (Biosilicate®) and of its ionic dissolution products on key parameters of the development of the osteogenic phenotype in vitro. Rat calvaria-derived osteogenic cells were plated on Biosilicate® discs that were pre-conditioned either with supplemented culture medium or serum-free medium for 3 days. In addition, osteogenic cells grown on bioinert glass coverslips were exposed to the ionic dissolution products of the Biosilicate®. The results showed that the supplemented culture medium used for the Biosilicate® surface conditioning exhibited a high concentration silicium and calcium. At 1, 3, and 7 days, cell viability was significantly higher for the conditioned Biosilicate® sufaces, whereas reduced cell viability was observed for cultures grown on glass coverslips and exposed to the ionic dissolution products of Biosilicate®. At day 3, cells grown on Biosilicate® groups were less spread compared with those on glass coverslips. At the same time point, whereas the surface topography of glass coverslips was smooth, Biosilicate® discs exhibited a network of submicron and nanoscale pits. Changes in the labeling pattern of the cytoskeleton proteins actin, vimentin, tubulin and vinculin, and of &alpha;5 integrin and fibronectin were only observed for cells grown on Biosilicate® surfaces. At the end of the proliferative phase (day 7), expression levels of Runx2, alkaline phosphatase (ALP) and bone sialoprotein (BSP) mRNAs were significantly higher for cultures grown on conditioned Biosilicate® surfaces; the exposure of cells to the ionic dissolution products increased Runx2 and ALP mRNA levels. At day 14, significantly more extensive areas of matrix mineralization were detected for cultures grown on Biosilicate® discs that were pre-conditioned with supplemented culture medium. The results showed that the conditioning of Biosilicate® surfaces with culture medium prior to cell plating supports key aspects of cell-substrate interactions, increasing and/or accelerating expression of the osteoblastic cell phenotype. Furthermore, the exposure of cells to the ionic dissolution products of Biosilicate® inhibits the progression of osteogenic cell cultures on bioinert glass coverslips, despite its positive effect on expression of osteoblastic markers.
43

Osteogênese in vitro sobre vitrocerâmica 100% cristalina e altamente bioativa (Biosilicato®): efeitos do condicionamento de superfície e dos produtos de dissolução iônica / In vitro osteogenesis on a highly bioactive glass ceramic (Biosilicate®): effects of surface conditioning and of its ionic dissolution products

Larissa Moreira Spinola de Castro Raucci 29 May 2009 (has links)
O objetivo deste estudo foi avaliar o efeito do condicionamento de superfície de uma vitrocerâmica 100% cristalina e altamente bioativa (Biosilicato®) e de seus produtos de dissolução iônica sobre diferentes parâmetros do desenvolvimento do fenótipo osteogênico in vitro. Previamente ao plaqueamento de células osteogênicas de calvárias de ratos, discos de Biosilicato® foram condicionados, por 3 dias, em meio de cultura suplementado, com ou sem soro fetal bovino a 10%. Células osteogênicas expostas aos produtos de dissolução iônica do Biosilicato® foram também cultivadas sobre lamínulas de vidro bioinerte. Discos de Biosilicato e lamínulas de vidro foram utilizados como controles. Os resultados mostraram que o tratamento de superfície de Biosilicato® aumenta expressivamente a concentração de silício e cálcio no meio de cultura. Em 1, 3 e 7 dias, foram determinados os maiores valores de viabilidade celular em superfícies de Biosilicato® condicionado, enquanto que entre os grupos de lamínulas de vidro, observou-se menor viabilidade em culturas expostas aos produtos de dissolução iônica do Biosilicato®. Em 3 dias, células sobre todas as superfícies de Biosilicato® apresentavam-se menos espraiadas quando comparadas àquelas sobre lamínulas de vidro; neste período, a topografia das superfícies dos grupos de Biosilicato® caracterizava-se por rede de cavidades na submicro e nanoescala, enquanto que a lamínula apresentava superfície plana. Alterações no padrão de marcação das proteínas citoesqueléticas actina, vimentina, tubulina e vinculina, da subunidade de integrina &alpha;5 e da fibronectina eram observadas apenas em células crescidas sobre as superfícies de Biosilicato®. Ao final da fase proliferativa (7 dias), foram observados maiores níveis relativos de expressão de RNA mensageiro para Runx2, sialoproteína óssea (BSP) e fosfatase alcalina (ALP) em culturas crescidas sobre superfícies condicionadas de Biosilicato®; a exposição aos produtos de dissolução iônica aumentou a expressão de Runx2 e ALP nos grupos de lamínula de vidro. Em 14 dias, culturas sobre Biosilicato® condicionado em meio de cultura com soro exibiam áreas mais extensas de mineralização. Os resultados deste estudo mostraram que o condicionamento de superfícies de Biosilicato® previamente ao plaqueamento celular favorece aspectos da interação célula-substrato, promovendo maior viabilidade celular e aumentando e/ou acelerando o desenvolvimento do fenótipo osteogênico in vitro. A exposição aos produtos de dissolução iônica do Biosilicato® inibe a progressão de culturas osteogênicas sobre lamínulas de vidro bioinerte, apesar de aumentar a expressão de marcadores osteoblásticos. / The aim of the present study was to evaluate the effect of surface conditioning of a highly bioactive, fully crystalline glass-ceramic in the Na2O-CaO-SiO2-P2O5 system (Biosilicate®) and of its ionic dissolution products on key parameters of the development of the osteogenic phenotype in vitro. Rat calvaria-derived osteogenic cells were plated on Biosilicate® discs that were pre-conditioned either with supplemented culture medium or serum-free medium for 3 days. In addition, osteogenic cells grown on bioinert glass coverslips were exposed to the ionic dissolution products of the Biosilicate®. The results showed that the supplemented culture medium used for the Biosilicate® surface conditioning exhibited a high concentration silicium and calcium. At 1, 3, and 7 days, cell viability was significantly higher for the conditioned Biosilicate® sufaces, whereas reduced cell viability was observed for cultures grown on glass coverslips and exposed to the ionic dissolution products of Biosilicate®. At day 3, cells grown on Biosilicate® groups were less spread compared with those on glass coverslips. At the same time point, whereas the surface topography of glass coverslips was smooth, Biosilicate® discs exhibited a network of submicron and nanoscale pits. Changes in the labeling pattern of the cytoskeleton proteins actin, vimentin, tubulin and vinculin, and of &alpha;5 integrin and fibronectin were only observed for cells grown on Biosilicate® surfaces. At the end of the proliferative phase (day 7), expression levels of Runx2, alkaline phosphatase (ALP) and bone sialoprotein (BSP) mRNAs were significantly higher for cultures grown on conditioned Biosilicate® surfaces; the exposure of cells to the ionic dissolution products increased Runx2 and ALP mRNA levels. At day 14, significantly more extensive areas of matrix mineralization were detected for cultures grown on Biosilicate® discs that were pre-conditioned with supplemented culture medium. The results showed that the conditioning of Biosilicate® surfaces with culture medium prior to cell plating supports key aspects of cell-substrate interactions, increasing and/or accelerating expression of the osteoblastic cell phenotype. Furthermore, the exposure of cells to the ionic dissolution products of Biosilicate® inhibits the progression of osteogenic cell cultures on bioinert glass coverslips, despite its positive effect on expression of osteoblastic markers.
44

ESTUDO DA ADESÃO ENTRE PAPEL CARTÃO E POLIETILENO EM EMBALAGENS LONGA VIDA: INFLUÊNCIA DE ASPECTOS QUÍMICOS E FÍSICOS

Madeira, Danielle Müller Ferreira 27 February 2013 (has links)
Made available in DSpace on 2017-07-21T20:42:46Z (GMT). No. of bitstreams: 1 Danielle M Ferreira Madeira.pdf: 2830948 bytes, checksum: b0683133449a7aa9574bf79758c203d4 (MD5) Previous issue date: 2013-02-27 / The objective of this work was to study the surface adhesion of polyethylene on the liquid paper board. By using surface characterization, the chemical and physical interactions between the paper board and polyethylene were studied. Paper board samples were laminated with low density polyethylene with an extruder, in order to evaluate the adhesion forces of the following samples: 1) Paper board coating with different latex composition; 2) paper board bottom layer (brown side) with surface sizing (starch) and, 3) paper board bottom layer (brown side) without surface sizing (starch). It was also evaluated in the extruded samples treated with flame the polyethylene adhesion. The following analyses were used in other to characterize the paper board surface: 1) Contact angle analysis for surface energy determination, 2) Confocal laser scanning microscopy for surface roughness analysis and, 3) FTIR spectroscopy Attenuated Total Reflectance (ATR) to evaluate differences in the functional groups. The characterization results were correlated with the increase of polyethylene adhesion forces on the paper board surface. It was observed that flame treatment on the paper board surface increased the surface tension, thus increasing the adhesion forces of the polyethylene. In comparison to the styrene-butadiene latex, the styrene acrylic latex, which contains polar groups in its composition, improved the adhesion forces of the polyethylene with the paper board top layer (white side). For the paper board bottom layer (brown side) with no surface sizing, the polyethylene adhesion was superior when compared to the sized paper board. It can be explained by the increase on the surface smoothness of the paper which may interfere on the polyethylene adhesion. The flame treatment may have caused the oxidation of functional groups on the surface of the paper board, resulting in the surface tension increase and, consequently, increasing the polyethylene adhesion. The surface tension has shown to be an excellent indicator for polyethylene adhesion due to its linear correlation with polyethylene adhesion forces. On the other hand, it has not been observed difference on surface roughness on the studied samples. The FTIR-ATR technique has not been sensitive for the detection of chemical differences among the samples treated with and without flame. However, this technique can be used to verify the latex composition in the paper board coating. The Peel Test Method (180º) which is used to evaluate the adhesion force, presents more reliable results than the manual delamination test that depends on the analyst. / O objetivo deste trabalho foi estudar a adesão de polietileno à superfície do papel cartão utilizado na produção da embalagem Longa Vida. Através de técnicas de caracterização de superfície foram verificadas as interações químicas e físicas existentes entre o papel cartão e o polietileno. Amostras de papel cartão foram laminadas com polietileno de baixa densidade em uma extrusora para avaliar a força de adesão nas seguintes amostras: 1) “coating” do papel cartão com diferentes látex na composição da tinta de revestimento. 2) base do papel cartão (lado marrom) com colagem superficial com amido. 3) base do papel cartão (lado marrom) sem colagem superficial com amido. Nas amostras extrusadas também foi avaliada a adesão de polietileno quando a superfície do papel cartão foi tratada com chama. Análise do ângulo de contato para obtenção da energia superficial, microscopia confocal a laser, para verificar efeitos na rugosidade superficial, e análise de infravermelho (ATR – reflectância total atenuada), para avaliar diferenças dos grupos funcionais, foram também utilizadas para a caracterização da superfície do papel cartão. O resultado da caracterização foi correlacionado com aumento das forças de adesão de polietileno à superfície do papel cartão. Para os casos estudados, observou-se que o tratamento de superfície feito com chama no papel cartão aumentou a energia superficial, elevando assim a força de adesão ao polietileno. O uso de látex estireno-acrílico, que apresenta grupos polares na composição, também propiciou melhor adesão de polietileno na cobertura (lado branco do papel cartão) comparado ao látex estireno-butadieno. Para a base do papel cartão (lado marrom) sem a colagem superficial, a adesão de polietileno se mostrou superior à condição com colagem, pois esta gera maior nivelamento da superfície, deixando a base do papel cartão mais lisa, dificultando assim a adesão de polietileno. Os tratamentos de superfície com chama podem ter causado a oxidação da superfície do papel cartão, gerando assim um aumento de grupos polares na superfície, aumentando a energia superficial da mesma e, consequentemente, melhorado a adesão de polietileno. A energia superficial pode ser vista como um excelente indicativo para adesão de polietileno, pois se verificou uma correlação linear onde quanto maior a energia superficial do papel cartão, maior a força de adesão ao polietileno. Por outro lado, a rugosidade superficial não mostrou diferenças entre as amostras estudadas. A técnica de infravermelho (ATR) não foi sensível para detectar diferenças químicas entre os tratamentos com e sem chama. No entanto, esta técnica pode ser utilizada para verificar a composição, quanto ao tipo de látex, usado na tinta de revestimento do papel cartão. O método Peel Test em 1800, usado para avaliar a força de adesão, apresenta resultados mais confiáveis do que somente a avaliação através da delaminação manual, que depende muito do analista e sua percepção.
45

Efeito da largura temporal de pulso do Laser de Er:YAG em zircônia pré-sinterizada / Effect of Er:YAG laser pulse widths on pre-sintered zirconia

Silva, Beatriz Togoro Ferreira da 19 October 2015 (has links)
Este estudo se propôs a analisar os efeitos das diferentes larguras temporais de pulso do laser de Er:YAG na rugosidade superficial, na perda de volume do material e na altura do degrau formado em uma Y-TZP (Yttrium-stabilized Tetragonal Zirconia Polycrystal) pré-sinterizada. Foram utilizados 5 blocos de Y-TZP pré-sinterizados destinados ao uso CAD/CAM que foram seccionados, obtendo-se 63 espécimes padronizados. Em seguida, esses espécimes foram lixados com uma sequência decrescente de lixas para padronização da superfície. Os grupos experimentais foram compostos a partir de 1 fator de variação - o tratamento de superfície. Os espécimes foram irradiados com o laser de Er:YAG (Fidelis III Fotona, Eslovênia) - 2,94 ?m, 100 mJ, 15,87J/cm2, 10 Hz, 1W, 7 mm, 60% água/40% ar. Assim formaram-se 7 grupos experimentais (n=9): G1 (50 ?s); G2 (100 ?s); G3 (300 ?s); G4 (600 ?s); G5 (1000 ?s); G6 (Abrasão triboquímica com partículas de 30 ?m); G7 (Sem tratamento). Após os tratamentos de superfície, os espécimes foram sinterizados em forno específico, de acordo com as recomendações do fabricante. Foram capturadas imagens em Microscópio Confocal a Laser 3D de cada espécime e avaliadas por meio de um software. A análise dos grupos irradiados revelou um aumento da rugosidade nos grupos G1, G2, G3 e G4 quando comparados aos grupos G6 e G7. O grupo G5 apresentou superfície totalmente plana e desfavorável para retenção. No que se refere à perda de volume e formação de degrau, os grupos G1, G2 e G3 demonstraram grande perda de volume e grande altura de degrau formado, o que pode levar a uma desadaptação da peça protética. No grupo G4 foram observados valores de rugosidade satisfatórios com pouca perda de volume e pequena altura de degrau formado, semelhante ao que foi notado para a abrasão trioboquímica (G6), podendo ser indicada para tratamento de superfície de Y-TZP pré-sinterizada. A irradiação com o laser de Er:YAG promoveu um padrão morfológico com muitas irregularidades, característico de ablação para os grupos G1, G2, G3 e G4 e, para todos os protocolos utilizados, não foi observada a presença de trincas ou carbonização. Sugere-se que a largura temporal de 600 ?s (G4) seja a mais indicada como alternativa para tratamento de superfície, objetivando a criação de micro-retenções superficiais, com pouca perda de volume de material e que, ao mesmo tempo, não provoque danos à estrutura da cerâmica policristalina. / This study evaluated the effects of different Er:YAG laser pulse width protocols on surface roughness, loss of volume of the material and the step height formed of pre-sintered Yttrium-stabilized tetragonal Zirconia Polycrystal (Y-TZP) by three-dimensional profilometric assessment. Blocks of pre-sintered Y-TZP were cut providing 63 standard 5mm thick samples which were divided by surface treatment, as follows (n=9): G1 (50?s); G2 (100?s); G3 (300?s); G4 (600?s); G5 (1000?s); G6 (tribochemical silica coating); G7 (Untreated). Laser settings: The Er:YAG laser (Fidelis III; Fotona, Ljubljana, Slovenia) 100mJ, 15,87J/cm2, 10Hz, 1W, (60%) and air (40%) cooling. After treated or not, samples were sintered according to the manufacturer\'s recommendations. Roughness, volume loss and step and were analyzed by 3D profilometric assessment with confocal laser microscopy. Irradiated groups showed an increased roughness in the groups G1, G2, G3 and G4 when compared to G6 and G7 groups. The G5 group showed a completely flat and unfavorable surface for retention. The groups G1, G2 and G3 shown great loss of volume and the step height formed, which can lead to a gap on the crowns. In G4 were observed satisfactory roughness with little loss of volume and the step height formed similar to G6. Irrespective of laser protocol, any of the specimens showed presence of cracks and carbonization. It is suggested that the pulse width 600?s (G4) is the most suitable pulse width protocol as an alternative surface treatment, promoting micro-retention, with little loss of volume of material, comparable to gold standard treatment.
46

EFEITO DE DIFERENTES TRATAMENTOS DE SUPERFÍCIE NA RESISTÊNCIA À FLEXÃO BIAXIAL E RESISTÊNCIA DE UNIÃO ENTRE CIMENTO RESINOSO E UMA CERÂMICA Y-TZP / EFFECTS OS DIFFERENTS SURFACE TREATMENT ON BIAXIAL FLEXURE STRENGTH AND BOND STRENGTH OF A RESIN CEMENT AND CERAMIC Y-TZP.

Pozzobon, Joao Luiz 26 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study evaluated the effect of different surface treatments on the biaxial flexure strength and reliability of a ceramic Y-TZP by using Weibull analysis. In addition, the influence of these methods on the bond strength of a resin cement and ceramic Y-TZP were studied. The surface treatments analyzed were the following: air-borne particle abrasion with silica-coated aluminum oxide particles for 10 s with 10 mm distance (TBS); application of a ceramic overglaze on the surface and etching with 10% hydrofluoric acid gel (HF) for 1 min (GLZ1), 5 min (GLZ5), 10 min (GLZ10), and 15 min (GLZ15); and deposition of 5 nm thick SiO2 nanofilm by physical vapor deposition (PVD) (SNF). This last treatment was performed only to study the biaxial flexural strength. Regarding the biaxial flexural strength and reliability of the material, 210 discs (15mm × 1.2mm) of Y-TZP were made following the ISO 6872-1999 and then sintered according to the manufacturer`s instructions. The discs (n=30) were divided according to the different surface treatments applied (6 groups), apart from the control group which did not receive any treatment. Using the flexural strength data, a Weibull statistical analysis was performed to describe the reliability of the ceramic material. To evaluate the bond strength, 75 Y-TZP (In-Ceram YZ, Vita) blocks (5×5×4 mm) were assigned into five groups (n=15) according to the different surface treatments. Specimens of composite resin (diameter=3.25mm; height=3mm) were cemented to the Y-TZP blocks using resin cement (Relyx ARC). All the specimens were subjected to aging (10,000 thermal cycles and storage for 90 days), tested in shear, analyzed under a stereomicroscope and under a scanning electron microscope (SEM), and measured by phase transformation analysis (XRD). In relation to the biaxial flexure, the TBS group statistically presented the highest strength values, and the groups with glaze application followed by etching with hydrofluoric acid (GLZx) showed the lowest values, independent of the HF treatment time. However, no surface treatment negatively influenced the reliability of the material when compared with the control group with no surface treatment, according to the Weibull analysis results. With respect to adhesion, the TBS groups showed the highest bond strength values. It may be concluded that treatment with blasting (TBS group) confers the best bond strength to ceramics out of all the tested methods, without negatively influencing the strength of the material. / Este estudo avaliou o efeito de diferentes tratamentos de superfície na resistência à flexão biaxial e confiabilidade da cerâmica Y-TZP usando a análise de Weibull. Além disso, a influência desses métodos na resistência de união entre um cimento resinoso e a cerâmica Y-TZP foi estuda. Os tratamentos de superfície analisados foram: jateamento com partículas de óxido de alumínio revestidas por Sílica por 10 segundos e com 10 mm de distância (TBS); aplicação de glaze na superfície da cerâmica e condicionamento com ácido fluorídrico gel 10% (HF) por 1 min (GLZ1), 5 min (GLZ5), 10 min (GLZ10) e 15 min (GLZ15) e deposição de nanofilme de SiO2 com 5 nm de espessura através da deposição física de vapor (PVD) (SNF). Este último tratamento foi utilizado apenas no trabalho referente a resistência à flexão biaxial. Para a resistência à flexão biaxial e confiabilidade do material 210 discos (15mm x 1.2mm) de Y-TZP foram confeccionados seguindo a ISO 6872-1999 e sinterizados de acordo com instruções do fabricante. Os discos foram divididos (n=30) de acordo com o tratamento de superfície aplicado (6 grupos) além do grupo controle o qual não recebeu tratamento. Através dos dados de resistência à flexão, foi realizada também a análise estatística de Weibull, a qual é utilizada para descrever a confiabilidade de materiais cerâmicos. Para avaliar a resistência de união, 75 blocos de Y-TZP (In-Ceram YZ, Vita) (5×5×4 mm) foram divididos em cinco grupos (n=15) de acordo com o tratamento de superfície. Espécimes de resina composta (diâmetro=3.25mm; altura=3mm) foram cimentados nos blocos de Y-TZP usando um cimento resinoso (Relyx ARC). Todos os espécimes foram submetidos ao envelhecimento (10,000 ciclos e armazenamento por 90 dias), ao teste de cisalhamento, analisados no estereomicroscópio, no microscópio eletrônico de varredura (MEV) e submetidos a análise de transformação de fase (XRD). Com relação à flexão biaxial, pode-se notar que o grupo TBS apresentou o maior valor de resistência e os grupos com aplicação do glaze seguido de condicionamento com ácido fluorídrico mostraram os menores valores independente do tempo de condicionamento. Entretanto nenhum tratamento influenciou de maneira negativa a confiabilidade do material quando comparado com o grupo controle. Para os resultados de adesão, o grupo TBS obteve os maiores valores de resistência de união. É possível concluir que o tratamento com jateamento (grupo TBS) confere uma melhor resistência de união na cerâmica não influenciando de forma negativa na resistência flexural desse material.
47

AVALIAÇÃO DE TRATAMENTOS DE SUPERFÍCIE DA CERÂMICA YTZP SOBRE A RESISTÊNCIA DE UNIÃO A UM CIMENTO RESINOSO / EVALUATION OF Y-TZP SURFACE TREATMENTS ON BOND STRENGTH TO A RESIN CEMENT

May, Michele Mirian 03 August 2015 (has links)
This in vitro study was conducted to evaluate the influence of surface treatments on the bond strength between an yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic and resin cement. For this purpose, 120 Y-TZP blocks (IPS e.max® ZirCAD in inLab®) were randomly distributed into 12 experimental groups (n = 10), according to six surface treatment strategies and two storage conditions (24 hours post cementation and after 60 days in water and 10,000 thermocicles): AS (as sintered, no treatment); TBS (tribochemical silica coating followed by silanization); AAP (particle abrasion with 50 μm aluminum oxide followed by application of Monobond®Plus); FS (fusion sputtering); SN (5 nm SiO2 nanofilm deposition and silanization) and FSSN (FS + SN). The Y-TZP blocks were embedded in acrylic resin and cylinders of resin cement (Ø=0.96 mm x 1 mm in height) (RelyX ARC) were built up on the ceramic surface. After the storage, the specimens were submitted to microshear test (μSBS) (1 mm/min) in a universal testing machine. After testing, the surfaces were analyzed with a stereomicroscope and scanning electron microscope (SEM) in order to categorize the failure modes. One additional specimen per surface treatment strategy was analyzed by X-ray diffraction, for phases content, and by SEM for micromorphology observation. Bond strength values were statistically analyzed by Kruskal-Wallis and Mann Whitney tests for surface treatments (p <0.001) and aging factor (p <0.05). In both storage conditions, TBS and AAP provided higher bond strength values, followed by FSSN, FS and SN groups. The aging negatively influenced the results, with one exception for the FS. An increase in the amount of monoclinic phase was observed in the abraded groups. Sandblasting of alumina particles followed by application of a primer with MPA is as effective as the tribochemical treatment combined with silane for pretreatment of the Y-TZP surface, with respect to the bond strength to the composite. / No presente trabalho objetivou-se avaliar, in vitro, o efeito de diferentes tratamentos de superfície na resistência de união de uma cerâmica à base de zircônia policristalina tetragonal estabilizada por ítria (Y-TZP) a um cimento resinoso. Para tanto, 120 blocos de Y-TZP (IPS e.max® ZirCAD for inLab®, Ivoclar-Vivadent, Schaan, Liechtenstein) foram distribuídos randomicamente em 12 grupos experimentais (n=10), conforme 6 estratégias de tratamento de superfície e 2 condições de envelhecimento (24 horas e após o envelhecimento em água e termociclagem): AS (sem tratamento); TBS (jateamento de partículas de alumina revestidas por sílica e silanização); AAP (abrasão com partículas de alumina seguida da aplicação de primer universal); FS (pulverização de micropartículas de zircônia na superfície livre da Y-TZP e após, fusão por sinterização); SN (deposição de nanofilme de sílica com 5 nm) e FSSN (FS seguido de SN). Os blocos de Y-TZP foram embutidos em resina acrílica e microcilindros de cimento resinoso (0,96 mm de diâmetro; 1 mm de altura) (RelyX ARC) foram confeccionados na superfície cerâmica. Após o armazenamento, os testes de microcisalhamento foram conduzidos a uma velocidade de 1 mm/min, em máquina de ensaios universal. Após o teste, as superfícies foram analisadas com estereomicroscópio e microscópio eletrônico de varredura (MEV) para caracterização das falhas. Em um espécime adicional, também foi conduzida análise de fases do material por difração de raios-X e caracterização da micromorfologia de superfície em MEV. Os valores de resistência de união foram submetidos aos testes estatísticos Kruskal-Wallis e Mann Whitney para os tratamentos testados (p<0.001) e para o fator envelhecimento (p<0.05). Em ambas as condições de envelhecimento, TBS e AAP proporcionaram os maiores valores de resistência adesiva, seguidos dos grupos FSSN, FS e SN. O envelhecimento influenciou negativamente os resultados, com única exceção para o FS. A difractometria revelou aumento de conteúdo monoclínico nos grupos jateados. FS não alterou a percentagem de fase monoclínica. O jateamento de partículas de alumina seguido da aplicação de um primer com MPA apresentou-se tão efetivo quanto o tratamento triboquímico aliado ao silano, para o pré-tratamento da superfície da Y-TZP, no que diz respeito à resistência de união ao compósito.
48

Efeito da largura temporal de pulso do Laser de Er:YAG em zircônia pré-sinterizada / Effect of Er:YAG laser pulse widths on pre-sintered zirconia

Beatriz Togoro Ferreira da Silva 19 October 2015 (has links)
Este estudo se propôs a analisar os efeitos das diferentes larguras temporais de pulso do laser de Er:YAG na rugosidade superficial, na perda de volume do material e na altura do degrau formado em uma Y-TZP (Yttrium-stabilized Tetragonal Zirconia Polycrystal) pré-sinterizada. Foram utilizados 5 blocos de Y-TZP pré-sinterizados destinados ao uso CAD/CAM que foram seccionados, obtendo-se 63 espécimes padronizados. Em seguida, esses espécimes foram lixados com uma sequência decrescente de lixas para padronização da superfície. Os grupos experimentais foram compostos a partir de 1 fator de variação - o tratamento de superfície. Os espécimes foram irradiados com o laser de Er:YAG (Fidelis III Fotona, Eslovênia) - 2,94 ?m, 100 mJ, 15,87J/cm2, 10 Hz, 1W, 7 mm, 60% água/40% ar. Assim formaram-se 7 grupos experimentais (n=9): G1 (50 ?s); G2 (100 ?s); G3 (300 ?s); G4 (600 ?s); G5 (1000 ?s); G6 (Abrasão triboquímica com partículas de 30 ?m); G7 (Sem tratamento). Após os tratamentos de superfície, os espécimes foram sinterizados em forno específico, de acordo com as recomendações do fabricante. Foram capturadas imagens em Microscópio Confocal a Laser 3D de cada espécime e avaliadas por meio de um software. A análise dos grupos irradiados revelou um aumento da rugosidade nos grupos G1, G2, G3 e G4 quando comparados aos grupos G6 e G7. O grupo G5 apresentou superfície totalmente plana e desfavorável para retenção. No que se refere à perda de volume e formação de degrau, os grupos G1, G2 e G3 demonstraram grande perda de volume e grande altura de degrau formado, o que pode levar a uma desadaptação da peça protética. No grupo G4 foram observados valores de rugosidade satisfatórios com pouca perda de volume e pequena altura de degrau formado, semelhante ao que foi notado para a abrasão trioboquímica (G6), podendo ser indicada para tratamento de superfície de Y-TZP pré-sinterizada. A irradiação com o laser de Er:YAG promoveu um padrão morfológico com muitas irregularidades, característico de ablação para os grupos G1, G2, G3 e G4 e, para todos os protocolos utilizados, não foi observada a presença de trincas ou carbonização. Sugere-se que a largura temporal de 600 ?s (G4) seja a mais indicada como alternativa para tratamento de superfície, objetivando a criação de micro-retenções superficiais, com pouca perda de volume de material e que, ao mesmo tempo, não provoque danos à estrutura da cerâmica policristalina. / This study evaluated the effects of different Er:YAG laser pulse width protocols on surface roughness, loss of volume of the material and the step height formed of pre-sintered Yttrium-stabilized tetragonal Zirconia Polycrystal (Y-TZP) by three-dimensional profilometric assessment. Blocks of pre-sintered Y-TZP were cut providing 63 standard 5mm thick samples which were divided by surface treatment, as follows (n=9): G1 (50?s); G2 (100?s); G3 (300?s); G4 (600?s); G5 (1000?s); G6 (tribochemical silica coating); G7 (Untreated). Laser settings: The Er:YAG laser (Fidelis III; Fotona, Ljubljana, Slovenia) 100mJ, 15,87J/cm2, 10Hz, 1W, (60%) and air (40%) cooling. After treated or not, samples were sintered according to the manufacturer\'s recommendations. Roughness, volume loss and step and were analyzed by 3D profilometric assessment with confocal laser microscopy. Irradiated groups showed an increased roughness in the groups G1, G2, G3 and G4 when compared to G6 and G7 groups. The G5 group showed a completely flat and unfavorable surface for retention. The groups G1, G2 and G3 shown great loss of volume and the step height formed, which can lead to a gap on the crowns. In G4 were observed satisfactory roughness with little loss of volume and the step height formed similar to G6. Irrespective of laser protocol, any of the specimens showed presence of cracks and carbonization. It is suggested that the pulse width 600?s (G4) is the most suitable pulse width protocol as an alternative surface treatment, promoting micro-retention, with little loss of volume of material, comparable to gold standard treatment.
49

Efeitos de diferentes tratamentos de superfície nas características superficiais, resistência adesiva, estabilidade da adesão e sobrevida de coroas/pilares de Y-TZP obtidos por CAD/CAM após ciclagem termomecânica e fadiga termomecânica acelerada / Effects of different surface treatments on the surface characteristics, adhesive strength, adhesive stability and survival of Y-TZP crowns/abutments obtained by CAD/CAM after thermomechanical cycling and accelerated thermomechanical fatigue

Danilo Flamini Oliveira 10 July 2017 (has links)
O estudo avaliou a efetividade de tratamentos de superfície na modificação superficial e adesão da zircônia ao cimento resinoso; a estabilidade de união após ciclagem termomecânica entre coroas metal free com copings em zircônia ou coroas monolíticas em zircônia e pilares personalizados do mesmo material, submetidos a tratamento superficial, e a influência destes na sobrevida dos sistemas protéticos após fadiga termomecânica acelerada. A pesquisa foi desenvolvida em 2 etapas. Na primeira, discos de zircônia foram distribuídos em sete grupos (n=6): G1 (Rocatec); G2 (ácido hidrofluorídrico 40%, 210 segundos); G3 (ácido hidrofluorídrico 40%, 210 segundos + Rocatec); G4 (nanopartícula ZrO2); G5 (nanopartícula SiO2); G6 (nanopartícula SiO2ZrO2); G7 (nanopartícula SiO2ZrO2 + silano). Uma amostra por grupo (n=1) foi analisada por espectroscopia infravermelho (FTIR), difração de raios-x (DRX) e microscopia eletrônica de varredura (MEV). As demais, submetidas a microscopia confocal a laser (n=5) para determinação da rugosidade superficial (Ra) e teste de cisalhamento. Molhabilidade e energia de superfície foram desenvolvidas em triplicata (n=3). G1, G3, G5 e G7 apresentaram valores de resistência ao cisalhamento superiores aos demais. Os melhores resultados definiram os tratamentos da etapa seguinte. Na segunda etapa, 162 análogos de implante conexão tipo Morse foram utilizados. Sobre eles, instaladas bases de titânio conectando pilar de zircônia ao análogo. Os 162 pilares foram distribuídos em 2 grupos de acordo com o ensaio: ciclagem termomecânica ou fadiga termomecânica acelerada. Para cada ensaio, duas modalidades restauradoras foram planejadas (Mono - coroa monolítica em zircônia, Pren - coping em zircônia + cobertura de vitrocerâmica fluorapatita). Pilares foram distribuídos a depender do tratamento recebido: MonoRo (Rocatec), MonoSi (nanopartícula SiO2), MonoSiZr (nanopartícula SiO2ZrO2 + silano). Grupo Pren recebeu os mesmos tratamentos. Sobre pilares, foram cimentadas coroas. Coroas monolíticas, copings e pilares foram obtidos via CAD/CAM. A adesão foi quantificada por teste de resistência à tração após ciclagem termomecânica (n=9) (2x106 ciclos, 2Hz, 120N e ciclos térmicos de 5º-55ºC). Valores de resistência à tração e padrões de falha obtidos foram registrados. Não foram encontradas diferenças significantes entre grupos para resistência à tração, mas o comportamento médio da força foi diferente nos grupos dependendo da falha. Sobrevida dos conjuntos foi analisada após fadiga termomecânica acelerada (n=18) (cargas progressivas a cada 2x104 ciclos de 80, 120, 160, 200, 240, 280 e 320N em 5Hz até 14x104 ou a falha, com ciclos térmicos de 5º- 55ºC). Resistência à fadiga foi comparada pela probabilidade de sobrevivência em cada intervalo. Padrões de falha foram classificados em ambos testes e amostras representativas de cada falha analisadas em MEV. MonoRo e MonoSiZr são semelhantes e têm maior probabilidade de sobrevivência que os demais. Pertencer a PrenSiZr, MonoSi, PrenRo ou PrenSi diminui a probabilidade de sobrevivência. / The study evaluated the effectiveness of surface treatments in surface modification and zirconia adhesion to resin cement; the bonding stability after thermomechanical cycling between free metal crowns with zirconia copings or monolithic zirconia crowns and customized abutments of the same material, subjected to surface treatments, and their influence in the survival of prosthetic systems after accelerated thermomechanical fatigue. The research was developed in 2 stages. In the first, zirconia discs were distributed in seven groups (n = 6): G1 (Rocatec); G2 (hydrofluoric acid 40%, 210 seconds); G3 (hydrofluoric acid 40%, 210 seconds + Rocatec); G4 (nanoparticle ZrO2); G5 (SiO2 nanoparticle); G6 (SiO2ZrO2 nanoparticle); G7 (SiO2ZrO2 nanoparticle + silane). One sample per group (n = 1) was analyzed by infrared spectroscopy (FTIR), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The others were submitted to laser confocal microscopy (n = 5) for determination of surface roughness (Ra) and shear test. Wettability and surface energy were developed in triplicate (n = 3). G1, G3, G5 and G7 presented higher values of shear strength than the others. The best results defined the treatments of the next stage. In the second stage, 162 Morse type implant analogues were used. On them, installed a titanium base, connecting zirconia abutment to analog. The 162 abutments were distributed in 2 groups according to the test: thermomechanical cycling or accelerated thermomechanical fatigue. For each test, two restorative modalities were planned (Mono - monolithic zirconia, Pren - zirconia coping + vitroceramic fluorapatite revestment). Abutments were distributed depending on the treatment received: MonoRo (Rocatec), MonoSi (nanoparticle SiO2), MonoSiZr (nanoparticle SiO2ZrO2 + silane). The Pren Group received the same treatments. Crowns were cemented on abutments. Monolithic crowns, copings and abutments were obtained by CAD/CAM. The adhesion was quantified by tensile strength test after thermomechanical cycling (n = 9) (2x106 cycles, 2Hz, 120N and thermal cycles of 5º-55ºC). Values of tensile strength and obtained failure patterns were recorded. No significant differences were found between groups for tensile strength, but mean force behavior was different in groups depending on failure. The survival of the sets was analyzed after accelerated thermomechanical fatigue (n = 18) (progressive loads every 2x104 cycles of 80, 120, 160, 200, 240, 280 and 320N in 5Hz up to 14x104 or failure, with thermal cycles of 5º- 55ºC). Fatigue resistance was compared by the probability of survival at each interval. Failure patterns were classified in both tests and representative samples of each failure analyzed in SEM. MonoRo and MonoSiZr are similar and more likely to survive than the others. Belonging to PrenSiZr, MonoSi, PrenRo or PrenSi reduces the probability of survival.
50

Avaliação da estabilidade, por meio da análise da frequência de ressonância (RFA), de implantes colocados na maxila posterior variando somente o tratamento de superfície: ensaio clínico randomizado / Stability evaluation, through resonance frequency analysis (RFA), of implants placed in the posterior maxilla varying only the surface treatments: randomized clinical trial

Marcelo Michele Novellino 03 May 2018 (has links)
Contexto: Modificações químicas da superfície dos implantes dentários com o objetivo de aumentar a molhabilidade resultam em uma osseointegração mais rápida e melhor. Objetivo: O objetivo deste estudo foi avaliar o quociente de estabilidade do implante (ISQ) (implant stability quotient) de implantes com geometria idêntica, mas com tratamentos de superfície diferentes: jateamento de areia e ataque ácido (SAE) e a mesma superfície com uma modificação química para aumento da hidrofilia, dentro das primeiras 16 semanas de cicatrização. Materiais e Método: neste estudo clínico randomizado um total de 64 implantes (32 SAE - Grupo Controle e 32 SAE modificado - Grupo Teste) com o mesmo desenho geométrico, comprimento e diâmetro (cônico e compressivo, 4,3x10 mm) foram colocados na maxila posterior de 21 pacientes parcialmente desdentados. Os valores de ISQ foram coletados no pós - cirúrgico imediato (T0), com 1 semana (T1), 2 (T2), 3 (T3), 5 ( T4), 8 (T5), 12 (T6) e 16 semanas (T7). Os resultados foram comparados por meio do ANOVA de medidas repetidas. Resultados: O grupo teste apresentou valores de ISQ mais altos que o grupo controle (ANOVA - p<0,01) a partir da 5a semana. Quando comparados os grupos em relação ao tempo necessário para se atingir o ISQ >= 70 como uma referência, houve uma diferença estatisticamente significante (p<0,01) e um Hazard Ratio de 2,24 (IC 1,62-3,11). No acompanhamento de um ano um paciente com 2 implantes abandonou a pesquisa, e estes não puderam mais ser avaliados. A taxa de sobrevida de ambos grupos foi de 100% após um ano de acompanhamento. Conclusão: O presente estudo sugere que implantes com superfície hidrofílica osseointegram mais rápido que implantes com superfície SAE convencional. O ganho de estabilidade do grupo teste foi 2,24 vezes mais rápido que do grupo controle após 5 semanas de avaliação em leitos na maxila posterior. / Background: Chemical modifications of dental implant surface, to improve the wettability, results in a faster and better osseointegration. Purpose: The aim of this study was to evaluate the implant stability quotient (ISQ) of implants with the same design, treated with two different surfaces: Sandblasted Acid-Etched (SAE) and hydrophilic SAE, within the initial 16 weeks of healing. Materials and Method: For this RCT a total of 64 implants (32 SAE - Control Group and 32 modified SAE - Test Group) with the same design, length and diameter (conical and compressive, 4.3x10 mm) were inserted in the posterior maxillae of 21 patients partially edentulous. The ISQ values were collected at the post-surgery (T0), 1-week (T1), 2-weeks (T2), 3- weeks (T3), 5-weeks (T4), 8-weeks (T5), 12-weeks (T6) and 16-weeks (T7). The statistic test was ANOVA. Results: Test group presented ISQ values higher than the Control group (ANOVA - p<0.01) from 5th week. When comparing groups regarding the amount of time required to achieve ISQ >= 70 as a reference, there was a statistically significant difference (p <0.01), and a HR (Hazard Ratio) of 2.24 (CI 1.62- 3.11). At the one-year follow up, there was a drop out of one patient and two implants were no longer evaluated. Survival rate for both groups was of 100% after one year of follow up. Conclusion: The current study suggests that implants with hydrophilic surface (modified SAE) integrates faster than implants with SAE surface. Stability gain of the tested group was 2.24 times faster than the control group after five weeks of evaluation at the posterior region of maxillae.

Page generated in 0.1184 seconds