• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 124
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 130
  • 130
  • 128
  • 61
  • 60
  • 38
  • 32
  • 28
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da resposta tecidual às pastas Guedes Pinto e de hidróxido de cálcio: análise edemogênica e ao microscópio óptico, em ratos

Takahashi, Karine [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:56:35Z : No. of bitstreams: 1 takahashi_k_me_araca.pdf: 875822 bytes, checksum: 94db31f595fb3801a8720b0bff61bce2 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Com o propósito de avaliar a resposta biológica imediata e tardia das pastas Guedes Pinto e de hidróxido de cálcio, materiais obturadores de canais de dentes decíduos, foram empregados o Teste Edemogênico e implantes em alvéolos. Para o teste edemogênico, foram utilizados 20 ratos machos, que após anestesia geral, receberam injeção intravenosa de Azul de Evans 1%. Decorridos 30 minutos, foi injetado 0,2ml de uma das pastas na região subcutânea dorsal do animal. Os animais foram sacrificados, nos períodos pós-operatórios de 3 e 6 horas, e as peças obtidas colocadas em formamida por 72 horas. Então realizada as leituras de absobância em espectrofotômetro com comprimento de onda de 630 nm. Para a análise morfológica, 48 ratos sofreram exodontia do incisivo central superior direito. Um implante de tubo de polietileno contendo uma das pastas foi posicionado no alvéolo, para análise após 7 e 28 dias. A pasta de hidróxido de cálcio causou maior edema que a Pasta Guedes Pinto. Na análise microscópica aos 7 dias, ambos materiais evidenciaram a formação de tecido conjuntivo rico em fibroblastos e vasos sangüíneos, com alguns macrófagos e linfócitos. Aos 28 dias, a Pasta de hidróxido de cálcio apresentou, nas áreas próximas ao material, tecido conjuntivo com elevado número de macrófagos e linfócitos, enquanto que nas áreas mais distantes havia trabéculas ósseas neoformadas. Para a Pasta Guedes Pinto verificou-se presença de trabéculas ósseas neoformadas junto à superfície do material, e número maior destas em áreas mais distantes. Pode-se concluir que a Pasta Guedes Pinto causou menor edema, e proporcionou menor interferência no processo de reparo. / In order to evaluate the biological response of two filling materials of deciduous teeth, Calcium Hydroxide and Guedes Pinto pastes, were used the Edemogenic Test and the implantation in rat socket. For the Edemogenic test, 20 male rats were anesthetized and received a intravenous injection of Evans Blue 1%. After 30 minutes, the animals received 0,2 ml of one of the pastes in the subcutaneous region. In the periods of 3 and 6 hours, the rats were killed and the reactions were evaluated by spectrophotometric determination of the spread of the stain. For the morphological analysis, made after 7 and 28 days, 48 rats had their upper right central incisor removed and, in the socket, placed tubes containing one of the pastes. Calcium Hydroxide paste caused more edema than Guedes Pinto paste. In the 7-day microscopical analysis, both materials showed connective tissue with lots of fibroblasts and vases, and some macrophages and lymphocytes. At 28 days, Calcium Hydroxide paste showed, in the areas nearest to the implantation, connective tissue with high level of macrophages and lymphocytes. In the distant areas, it showed neoformed osteal trabeculas. For Guedes Pinto paste, it was verified the presence of neoformed osteal trabeculas in the nearest areas, and a large number of them in the distant areas. We conclude that Guedes Pinto paste caused less edema and provide less interference in the repair process.
122

Avaliação da citotoxicidade de cimentos endodônticos quanto a liberação de peróxido de hidrogênio e óxido nítrico em culturas de macrófagos peritoneais de camundongos /

Silva, Paulo Tadeu da. January 2002 (has links)
Orientador: Iracilda Zeppone Carlos / Banca: Renato de Toledo Leonardo / Banca: Celso Kenji Nishiyama / Resumo: Avaliou-se a citotoxicidade dos cimentos Topseal, EndoRez, Tubli-Seal e Kerr Pulp Canal Sealer E.W.T. quanto a liberação de derivados do oxigênio no contato cimento/cultura de macrófagos peritoneais de camundongos. Respectivamente os cimentos que mais liberaram H2O2 na concentração de 9 mg/ml foi o Topseal > Zimosan > EndoRez > Tubli-Seal = Kerr Pulp E.W.T. e na concentração de 18 mg/ml foi o Topseal > Zimosan = EndoRez > Tubli-Seal > Kerr Pulp E.W.T. Os que mais liberaram NO na concentração de 9 mg/ml foi o LPS > Topseal > Kerr Pulp E.W.T. > Tubli-Seal = EndoRez e na concentração de 18 mg/ml foi o LPS > Topseal = Kerr Pulp E.W.T. > Tubli-Seal > EndoRez. / Abstract: It was evaluated the citotoxicity of the sealers Topseal, EndoRez, Tubli-Seal and Kerr Pulp Canal Sealer after exposure to rat peritoneal macrophage culture, due to oxigen derivate liberation. Respectively, the sealer that, liberated more H2O2 at 9 mg/ml concentration were Topseal > Zimosan > EndoRez > Tubli-Seal = Kerr Pulp E.W.T. and in concentration of 18 mg/ml were Topseal > Zimosan = EndoRez > Tubli-Seal > Kerr Pulp E.W.T. The greatest liberation of in NO concentration of 9 mg/ml were LPS > Topseal > Kerr Pulp E.W.T. > Tubli-Seal = EndoRez and in concentration of 18 mg/ml were LPS > Topseal = Kerr Pulp E.W.T. > Tubli-Seal > EndoRez. / Mestre
123

Avaliação histopatológica do reparo apical e periapical em dentes de cães com vitalidade pulpar, após tratamento de canais radiculares utilizando dois cimentos obturadores à base de resina epóxica. Análise do pH e concentração de cálcio total /

Rasquin, Luis Cardoso. January 2001 (has links)
Resumo: O objetivo do presente estudo foi o de avaliar comparativamente, dois cimentos obturadores de canal radicular à base de resina epóxica, AH Plus e Sealer Plus, através de duas diferentes metodologias. 1. Teste in vivo - Avaliação histopatológica em dentes de cães. Foram utilizados 36 canais radiculares de dentes pré-molares superiores e inferiores de 2 cães, com vitalidade pulpar, os quais, após o preparo biomecânico coadjuvado pela irrigação/aspiração e inundação com solução de hipoclorito de sódio a 1% (Líquido de Dakin), foram obturados pela técnica clássica complementada pela condensação lateral ativa, empregando os cimentos Sealer Plus (Grupo I) e AH Plus (Grupo II). Decorridos 90 dias após a obturação, os animais foram sacrificados por sobredose anestésica, as maxilas e mandíbulas removidas e fixadas em formol a 10%, durante 48 horas. Após processamento histológico de rotina, os cortes foram corados pela hematoxilina e eosina, pelo tricrômico de Mallory e Brown e Brenn. A análise histopatológica evidenciou que o cimento AH Plus, quanto à compatibilidade biológica, mostrou-se superior ao Sealer Plus, sendo o cimento que melhor permitiu a deposição de tecido mineralizado à nível apical, oferecendo um selamento quase completo na maioria dos casos, com infiltrado inflamatório ausente e quando presente era suave no tecido intersticial e/ou junto ao material obturador, assim como na região periapical. Já, com o cimento Sealer Plus, ocorreu predominantemente, selamento parcial, porém sempre acompanhado de infiltrado inflamatório de grau suave, no tecido intersticial, porém, mais concentrado, junto ao cimento obturador. Quando o material obturador era observado na região periapical, o infiltrado inflamatório apresentava-se, classificado como de grau moderado, concentrado próximo ao... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The scope of the present study was to evaluate comparativily, two root canal resin - based sealers - AH Plus and Sealer Plus through two different methodologies. 1. In vivo study - Histopathological evaluation in teeth of dogs. 36 root canals of lower and upper bicuspide teeth of 2 dogs with vital pulp, which after biomechanic preparation utilizing sodium hypochloride solution at 1% (Milton solution) were filling by classical technique complemented by active lateral condensation, using Sealer Plus (Group I) and AH Plus (Group II). 90 days after treatment, the animals were sacrificed by overdose anesthetical. After histopathological processing of routine, the sections were stained with hematoxiline and eosine, Mallory Trichromic and Brown and Brenn. The histopathological analysis had evidenced that the AH Plus sealer shows more biological compatibility in relation to the Sealer Plus being the sealer that shows more good deposition of mineralized tissue to the apical level, offering an almost full apical sealing in the majority of the cases, with infiltrated inflammatory absent and when present was mild in the interstitial tissue and/or together to the material sealer, as well as in the periapical region. With the Sealer Plus, partial apical sealing occurred, however always followed by infiltrated inflammatory of mild degree in the intersticial tissue, however, more concentrated, together to the filling material when in the periapical region, the inflammatory infiltrated was presented, classified as of moderate degree. 2. In vitro study - With the objective to analyze pH and clearing of total calcium by periods that had varied from 0 to the 5 days, the filling materials. AH Plus and Sealer Plus had been manipulated according to the manufacturers instructions. Samples of each sealer were... (Complete abstract, click electronic address below). / Orientador: Mario Roberto Leonardo / Coorientador: Léa Assed B. da Silva / Banca: Idomeo Bonetti Filho / Banca: Francisco José de Souza Filho / Banca: Jesus Djalma Pécora / Doutor
124

Influência do hidróxido de cálcio na penetração do cimento Epiphany TM nos túbulos dentinários e na adaptação às paredes do canal radicular: avaliação pela microscopia confocal de varredura a laser / Influence of calcium hydroxide dressing on Epiphany TM sealer depth of dentinal tubules and interface dentine-sealer: a confocal study

Éricson Janolio de Camargo 25 May 2009 (has links)
Avaliou-se a influência do curativo intra-canal com pasta de hidróxido de cálcio na penetração do cimento EpiphanyTM no interior dos túbulos dentinários e na adaptação do cimento às paredes dos canais radiculares utilizando-se a microscopia confocal de varredura a laser (MCVL). Foram utilizados 30 incisivos centrais inferiores humanos, extraídos, com apenas um canal radicular. O acesso ao canal foi realizado de forma convencional utilizando-se pontas diamantadas montadas em alta rotação, sob refrigeração. Os canais foram preparados pela técnica progressiva empregando-se instrumentos manuais e rotatórios de níquel-titânio, Protaper e Profile (conicidade 0.4). A irrigação foi realizada usando solução de hipoclorito de sódio a 1% e, ao final do preparo, o soro fisiológico. Após o preparo, os canais radiculares de todos os dentes receberam aplicação de EDTA a 17% por 3 minutos e irrigação final com soro fisiológico. A seguir, os dentes foram divididos em 3 grupos como segue: grupo 1 sem tratamento adicional (controle); grupo 2 curativo de Ca (OH)2 e grupo 3 - curativo de Ca (OH)2 e nova aplicação de EDTA. O curativo de Ca (OH)2 foi empregado na forma de pasta viscosa com propilenoglicol que foi inserida no canal com espiral de Lentulo. Após o curativo, os dentes foram armazenados a ± 37 °C por 14 dias. A remoção do curativo foi feita com irrigação com soro fisiológico e com instrumento manual. A seguir, os canais radiculares de todos os 30 espécimes foram obturados com o Sistema EpiphanyTM utilizando-se o primer, o cimento EpiphanyTM, cones principais de Resilon 40/0.4 e cones auxiliares fino-médio pela técnica da condensação lateral ativa. Antes da obturação, o cimento foi corado com Rodamina B. Foram feitas secções transversais a 3, 7 e 10 milímetros distantes do forame apical (terços apical, médio e cervical), cujas imagens foram analisadas em microscopia confocal por varredura a laser (MCVL). Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA) e teste Tukey, ambos com 5% de significância. Os resultados indicaram que a maior penetração de cimento no interior dos túbulos dentinários foi verificada nas secções dos terços cervical e médio do grupo II comparado aos grupos I e III. A penetração do cimento em todas as secções foi maior e estatisticamente significante nas faces vestibular e lingual. Em relação à adaptação do cimento às paredes dos canais radiculares, a fluorescência do cimento, considerando o perímetro total do canal mostrou regiões com falhas na interface dentina-cimento. A menor porcentagem de adaptação foi observada no grupo I (78%) comparado com os grupos II (93%) e III (86%) (p<0,05). Em canais obturados com o Sistema EpiphanyTM pela técnica da condensação lateral, o hidróxido de cálcio influenciou positivamente na profundidade de penetração do cimento no interior dos túbulos dentinários e na sua adaptação às paredes dos canais. / The aim of this study was to evaluate the influence of calcium hydroxide on the depth of dentinal tubule sealer penetration and the percentage of sealer-dentin interface in the coronal, middle and apical thirds teeth obturated with the EpiphanyTM Obturation System using 5 x and 40x confocal laser scanning microscopy. Thirty extracted single-rooted mandibular incisor human teeth were instrumented using 1.0 % NaOCl. The smear layer was removed using 17% EDTA for 3 minutes. The teeth were randomly assigned to 3 groups (n=10), according to the presence or absence of intracanal dressing and its removal: GI= non Ca(OH)2 dressing (control); G II= Ca(OH)2 + removal using saline solution and kfile # 40; and G3= Ca(OH)2 + removal using saline solution + kfile # 40 and 17% EDTA. One tooth from groups II and III were ramdomly selected for calcium hydroxide analysis. The calcium hidroxyde was labeled with fluorescent fluorescein and after 14 days of storage in 100% humidity at 37 degrees C, the dressings were removed from experimental groups. All root canals (control and experimental groups) were obturated with Resilon master points 40/0.4, Resilon points fine-medium and EpiphanyTM sealer labeled with fluorescent Rhodamine B dye. The sections cut from the coronal, middle and apical thirds of each root were viewed using 5x and 40x confocal laser scanning microscopy. Twoway ANOVA and Tukey test found significantly lower average depth of sealer penetration in apical sections than middle or coronal sections (p<0,05). The deepest sealer penetration was observed in the coronal and middle secctions of group II compared to the groups I and III. The sealer penetration in all sections was deeper and statistically different in the vestibular and lingual faces. A fluorescent sealer ring was seen around the canal wall in all sections presenting some gaps in the sealerdentin interface. Two-way ANOVA and Tukey tests showed significantly less percentage of sealer-dentin interface in the group I (78%) compared to groups II (93%) and III (86%) (p<0,05). Calcium hydroxide dressing affected positively the deep of sealer penetration and percentagem of sealer dentin interface in the root canals filled with EpiphanyTM resin based sealer.
125

Incidência de fratura radicular em dentes submetidos à terapia endodôntica e restaurados com pinos de fibra ou pinos metálicos : revisão sistemática e metanálise

Figueiredo, Fabricio Eneas Diniz de 26 January 2015 (has links)
Endodontically treated teeth have commonly lost most of their coronal structure. In order to restore them, an intrarradicular retainer is required to improve the restorations retention. Event though they have a proper clinical performance, their use has been related to failures such as root fractures. The aim of this systematic review was to analyze the outcome of clinical trials and cohort studies evaluating the post-retained restorations regarding the incidence rate of root fractures. The tested hypothesis was that the incidence rate related to the use of metal posts is higher than that of fiber posts. A search for clinical studies reporting the incidence of root fractures of restorations retained with fiber-reinforced composite posts or metal posts of endodontically treated teeth with more than 5-year of follow-up was conducted from inception to January 2014. Seven randomized clinical trials and 7 cohort studies were included. The overall incidence rate of root fractures was 5.13 (95% CI, 4.05-6.21) per 1000 posts-year. An almost 2-fold increase in the incidence rate of root fractures for prefabricated metal posts and carbon fiber posts compared with cast metal posts and glass fiber posts was observed, respectively. The pooled survival rate was 90% (95% CI, 85.5-93.3) for metal-based posts and 83.9% (95%, CI 67.6-92.8) for fiber-reinforced posts. The results of this study do not support the indication of fiber-reinforced posts based on a reduction of catastrophic failures. However, this review demonstrated the need for further well-designed clinical studies evaluating intra-radicular retainers. / Dentes submetidos à tratamento endodôntico geralmente apresentam grande destruição coronária. Para restaurá-los, o uso de retentor intrarradicular se faz necessário para melhorar a retenção da restauração. Apesar do sucesso clínico, falhas catastróficas têm sido atribuídas ao seu uso. O objetivo desta revisão sistemática foi analisar o resultado de ensaios clínicos e estudos de coorte que reportam a taxa de incidência de fraturas radiculares associadas ao uso de pinos intrarradiculares. A hipótese foi que dentes restaurados com uso de pinos metálicos apresentam maior incidência de fraturas radiculares que aqueles restaurados com de pino de fibra. Até Janeiro de 2014, buscou-se por estudos clínicos que avaliaram o índice de fraturas radiculares relacionadas ao uso de retentores intrarradiculares metálicos ou de fibra de vidro em dentes submetidos à tratamento endodôntico com tempo de acompanhamento superior a cinco anos. Sete ensaios clínicos randomizados e sete estudos de coorte foram incluídos. A taxa de sobrevivência estimada foi de 90% (95% intervalo de confiança {IC} 85,5 – 93,3) para pinos metálicos e 83,9% (IC 95%, 67,6 – 92,8) para pinos de fibra. A taxa de incidência total de fraturas radiculares (falhas catastróficas) foi similar entre pinos metálicos e de fibra. Pinos metálicos pré-fabricados e pinos de fibra de carbono apresentaram taxa de incidência de fraturas radiculares duas vezes maior quando comparadas com núcleos metálicos fundidos e pinos de fibra de vidro respectivamente. Os resultados deste estudo não demonstraram diferenças significantes na taxa de incidência de fraturas radiculares entre pinos metálicos e de fibra. Entretanto, os estudos incluídos nesta revisão apresentaram alto risco de viés, portanto, há necessidade de se realizarem estudos clínicos bem delineados para confirmar estes achados.
126

Estudos da composição quimica, comportamento termico e degradação do polimero guta-percha / Analysis of chemical composition, thermal properties and degradation of gutta-percha polymer

Ferreira, Claudio Maniglia 22 May 2007 (has links)
Orientador: Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T18:40:56Z (GMT). No. of bitstreams: 1 Ferreira_ClaudioManiglia_D.pdf: 2708039 bytes, checksum: d64f980c6dab5075c81d4c63643a7fe9 (MD5) Previous issue date: 2007 / Resumo: Este estudo teve como objetivo analisar o material obturador guta-percha (polímero trans 1,4- poliisopreno), através de: i) composição química e comportamento térmico de cinco marcas de cones de guta-percha nacionais; ii) degradação da guta-percha após uso de diferentes técnicas de obturação que utilizam o calor para sua plastificação e após diferentes períodos de tratamento. No estudo químico foram feitas a separação e a quantificação dos componentes orgânicos e inorgânicos pela dissolução em clorofórmio, associada às análises por Difração de raios-X, Microanálise Elementar e Microanálise de Raios-X por Espectrometria de Energia Dispersiva. Os comportamentos térmicos foram estudados por meio de Calorimetria Diferencial de Varredura (DSC) e Análise Termogravimétrica (TGA), os quais forneceram os efeitos do aquecimento sobre a guta-percha, bem como a ocorrência de picos endotérmicos, os quais correspondem às transformações cristalinas da polímero guta-percha, o que é traduzido em transições de fases (fase ß para a e fase a para amorfa). A degradação da guta-percha foi analisada através de Cromatografia de Permeação em Gel (GPC) e Espectroscopia em Infra-Vermelho (FT-IR), utilizando-se materiais obturadores colhidos de canais obturados após diferentes períodos (entre 2 e 30 anos) de tempo, e após uso de diferentes técnicas termoplastificadas de obturação do sistema de canais radiculares. Com base nos protocolos experimentais estudados, pode-se concluir que: i) foram quantificados os componentes químicos (guta-percha, ceras, resinas, óxido de zinco e sulfato de bário) de todas as marcas estudadas, sendo que foram notadas oscilações entre as porcentagens dos componentes de acordo com as marcas estudadas; ii) a maioria dos produtos analisados demonstrou comportamento típico de gutapercha em fase ß, apresentando dois picos endotérmicos, com exceção dos cones Dentsply 0.04 e 0.06, que demonstraram comportamento térmico de polímero tipo cis; iii) as técnicas da termocompactação (10 segundos) e a compressão vertical causaram degradações na guta-percha, gerando perda de massa molar; iv) aquecimentos excessivos do polímero guta-percha causam sua degradação, gerando a formação de produtos voláteis e perda de massa molar; v) A gutapercha (trans 1,4-poliisopreno) degrada-se lentamente no interior do canal radicular, sendo notada após 15 anos, porém este processo pode ser influenciado por fatores externos como a infecção endodôntica / Abstract: The main purpose of this study was to analyze the filling material gutta-percha on the following standards: i) chemical composition and thermal behaviour of five brands of Brazilian cones; ii) trans 1,4 polyisoprene polymer degradation after the use of different heating obturation techniques and after different periods of treatment. In the chemical analyzes separation and quantification of organic compounds were made through chloroform dissolution associated with XR diffraction analyzes, elemental microanalyses and X-ray microanalyses by Spectrometry of dispersive energy. Differential Scanning Calorimetry (DSC) and Thermogravimetry Analysis (TGA) were used to study the thermal behavior of gutta-percha cones, determining the temperature at which endothermic peaks occur, causing a transformation from the ß- to the a-form, and from the a- to amorphous phase. Polymer degradation was analyzed through chromatography of gel permeation (GPC) and infrared spectroscopy (FT-IR) using filling materials collected from root canals obturated after different periods of time (between 2 and 30 years) and after the use of different thermoplastic obturation techniques of root canal systems. Based on the studied experimental protocols, it can be concluded that: i) the quantification of chemical compounds (gutta-percha, wax, resin, zinc oxide and barium sulphate) showed variations in the percentages of compounds according to the studied brands; ii) most of the analyzed products showed characteristic behavior of phase ß in gutta-percha with two endothermic peaks, except for Dentsply cones 0.04 and 0.06 which demonstrated thermo behavior of polymer cis type; iii) thermomechanical compaction and vertical compression techniques promoted gutta-percha degradation causing loss of molar mass; iv) excessive polymer heating causes its degradation, forming volatile products and loss of molar mass, damaging its dimensional stability properties; v) trans 1,4 polyisoprene degrades itself slowly in the root canal which can be clearly seen after a period of 15 years and it can be influenced by external factors such as endodontic infection / Doutorado / Endodontia / Doutor em Clínica Odontológica
127

Performance de diferentes métodos de instrumentação radicular em dentes decíduos humanos e artificiais avaliado pela tomografia computadorizada por feixe cônico / Performance of different methods of root canal instrumentation in natural and artificial primary teeth evaluated by cone beam computed tomography

Anna Carolina Volpi Mello-Moura 10 August 2011 (has links)
No intuito de avaliar novas possibilidades de instrumentação radicular em dentes decíduos, o objetivo do presente estudo foi avaliar a performance de três diferentes métodos, manual e mecanizados, utilizando tomografia computadorizada por feixe cônico (TCFC). As técnicas utilizadas foram manual (MAN), rotatória com o sistema Protaper (ROT) e oscilatória com o sistema EndoEZE (OSC). Para o segundo objetivo, as técnicas foram testadas em dentes decíduos naturais e artificiais, para que também se pudesse avaliar a diferença entre a performance dos métodos nesses dois tipos de dentes. Após o acesso endodôntico inicial, imagens padronizadas foram realizadas em aparelho de TCFC (sistema iCat), com cortes sagital, coronal e axial. Após a instrumentação dos dentes pelos diferentes métodos, novas imagens foram realizadas. Avaliações quantitativas foram feitas medindo-se nas imagens axiais dos canais radiculares, a espessura das paredes e área do canal, em três diferentes regiões: terços cervical, médio e apical. Três desfechos foram considerados após instrumentação: desvio para a parede de risco, descentralização do canal e diferença na área do canal antes e após a instrumentação. Os valores foram comparados com análise de variância e teste de Tukey, ou com testes não paramétricos. Não houve diferença no desvio entre os métodos para os dentes anteriores artificiais e naturais. Nos posteriores naturais, entretanto, a técnica MAN apresentou maior desvio no terço cervical (p<0,05). Com relação as áreas do canal, para os dentes anteriores, o método ROT e OSC apresentaram maior desgaste que o MAN nos terços cervical e médio, mas no terço apical o OSC e o MAN foram semelhantes (p > 0,05). Para os posteriores, o método ROT apresentou um desgaste estatisticamente maior do que os demais apenas no terço apical (p<0,05). Análises qualitativas do padrão de desgaste de cada método de instrumentação radicular foram realizadas e representadas em gráficos e imagens obtidas pela TCFC. Avaliando as imagens, o padrão anatômico de todos os canais mostrou uma área maior da cervical e menor na apical. O método MAN apresentou uma tendência de preservar a anatomia inicial do canal em todos os terços. Já o ROT apresentou expressiva alteração no perfil anatômico em todos os terços e o método OSC atuou com maior expressão nas regiões cervical e média, comparado à região apical. Os dentes artificiais apresentaram similaridade de forma e radiopacidade com os dentes naturais, mas apresentaram resultados diferentes nos diversos desfechos, limitando seu uso como substitutos dos dentes naturais em pesquisas. Em conclusão, o método MAN apresenta boa performance na instrumentação radicular de dentes decíduos, mas o sistema oscilatório seria a melhor opção para obter as vantagens da instrumentação mecanizada. Em relação aos modelos de dentes artificiais utilizados, ainda necessitam ser aperfeiçoados para substituírem os dentes naturais nas pesquisas. / In order to appraise new options of root canal instrumentation in primary teeth, the aim of the present study was to evaluate the performance of three different methods, manual and mechanical, using cone beam computed tomography (CBCT). The techniques tested were manual (MAN), rotatory with Protaper system (ROT) and oscillatory with EndoEZE system (OSC). For the second objective, the techniques were assessed in natural and artificial primary teeth, in order to evaluate the difference in the performance of the methods in these types of teeth. After initial endodontic access, standardized scans were obtained by CBTC (iCat system), with sagittal, coronal and axial planes. After the root canal instrumentation of teeth with different methods, new images were achieved. Quantitative evaluations were performed measuring the thickness of root canal wall and canal area in the axial images of root canals, at three different places: coronal, middle and apical thirds. Three outcomes were considered after the instrumentation: canal transportation towards the side of root resorption, centering ability and difference in canal area before and after the instrumentation. The values were compared using ANOVA and Tukey test, or with non-parametric tests. There were no differences among the methods used in both natural and artificial anterior teeth concerning the canal transportation. In the natural posterior teeth, however, the MAN technique showed greater canal transportation towards the size of root resorption in the coronal third (p < 0.05). With regard to the canal area, for the anterior teeth, the ROT and OSC methods presented higher increase in canal area than the MAN in coronal and middle thirds, but in the apical third, OSC and MAN were similar (p > 0.05). In posterior teeth, the ROT method showed statistically higher increase in canal area than the other methods only in the apical third. Qualitative analysis of the shaping patterns of each root canal instrumentation method were carried out and presented in graphics and images obtained with CBCT. After evaluating the images, the shaping pattern of all root canals showed a larger area in the coronal and smaller in apical third. The MAN method tended to preserve the baseline anatomy of the root canal in all areas. The ROT method, on the other hand, presented more significant changes in the anatomical shaping in all thirds, and the OSC method showed higher increase in canal area in the coronal and middle thirds, compared to the apical third. The artificial teeth are very similar to natural teeth in their anatomical shape and radiopacity, but they yielded different results in several of the outcomes, which limits their use as substitute of natural teeth for research purpose. In conclusion, the MAN method presents good performance for root canal instrumentation in primary teeth, but the OSC system would be the best option to achieve the advantages of mechanical instrumentation. Concerning the artificial teeth used, some properties still need to be improved in order to substitute natural teeth for research purposes.
128

Tratamento endodôntico em sessão única utilizando diferentes sistemas de irrigação de canais radiculares: avaliação radiográfica e imunohistoquímica / Endodontic treatment in single session using different irrigation systems of root canals: radiographic and immunohistochemistry evaluation

Jesus, Sidineia Feitoza de 06 December 2018 (has links)
O objetivo deste estudo in vivo foi avaliar o reparo periapical e a expressão de mediadores inflamatórios após tratamento endodôntico em sessão única, dentes de cães com lesão periapical, utilizando protocolos de Irrigação por Pressão Apical Negativa, Irrigação Ultrassônica Passiva e Irrigação Convencional por Pressão Positiva. Um total de 80 canais radiculares de pré-molares de cães, com lesões periapicais experimentalmente induzidas, foram submetidos ao tratamento endodôntico em sessão única ou mantidas sem tratamento. Os dentes foram aleatoriamente divididos em 4 grupos: Grupo 1 - Irrigação por Pressão Apical Negativa (n=20 canais radiculares); Grupo 2 - Irrigação Ultrassônica Passiva (n=20 canais radiculares), Grupo 3 - Irrigação por Pressão Positiva (n=20 canais radiculares) e Grupo IV - Lesão periapical sem tratamento (n = 20 canais radiculares). Foi realizado os protocolos de irrigação com NaOCL 5,25% e instrumentação, utilizando limas Protaper rotatória F3-F4, em seguida os canais foram obturados com cimento AH Plus&reg;. Após 180 dias, os animais foram eutanasiados, as peças removidas e submetidas ao processamento histotécnico para análise imunohistoquímica para osteopontina, fator de necrose tumoral-&alpha; e interleucina 1-&alpha;. A análise radiográfica do reparo das lesões periapicais foi realizada por meio do Índice Periapical, obtido antes e 180 dias após o tratamento endodôntico. Os resultados obtidos foram submetidos à análise estatística por meio do teste de Exato de Fisher ou Kruskal-Wallis seguido pelo pós-teste de Dunn. O nível de significância adotado foi de 5%. Aos 180 dias após o tratamento endodôntico, o exame radiográfico mostrou a persistência de áreas radiolúcidas periapicais e descontinuidade da lâmina dura em 35% dos espécimes do Grupo pressão apical negativa, 40% dos espécimes do Grupo ultrassônica passiva e 40% dos espécimes do Grupo pressão positiva. Porém, quando comparado às radiografias previamente ao tratamento, em todos os grupos, pôde-se observar uma redução no tamanho das lesões periapicais. Não houve diferença entre os grupos, independente do protocolo de irrigação utilizado (p > 0,05). O tratamento endodôntico realizado em sessão única, resultou na menor síntese do fator de necrose tumoral-&alpha; e de osteopontina na região periapical, comparativamente à lesão periapical sem tratamento (p < 0,05), independente do protocolo de irrigação utilizado (p > 0,05). A produção de interleucina-1&alpha; não foi modulada pelo tratamento endodôntico (p > 0,05). Com base nas metodologias empregadas e nos resultados obtidos no presente estudo in vivo, pôde-se concluir que houve reparo da lesão periapical em cerca de 60% dos casos após tratamento endodôntico realizado em sessão única e menor síntese do fator de necrose tumoral-&alpha; e de osteopontina na região periapical, comparativamente à lesão periapical sem tratamento, independente do protocolo de irrigação utilizado (pressão apical negativa, ultrassônica passiva e por pressão positiva) / The aim of this in vivo study was to evaluate the periapical repair and the expression of inflammatory mediators after endodontic treatment in dogs with periapical lesions using Negative Apical Pressure Irrigation, Passive Ultrasonic Irrigation and Conventional Positive Pressure Irrigation protocols. A total of 80 root canals of premolars of dogs with periapical lesions experimentally induced, were submitted to endodontic treatment in a single session, or maintained without treatment. The teeth were randomly divided into 4 groups: Group 1 - Irrigation by Pressure, Apical Negative (n=20 root canals); Group 2 - Irrigation, Ultrasonic, Passive (n=20 root canals), Group 3 - Irrigation by Positive Pressure (n=20 root canals), and Group IV - Lesion periapical without treatment (n = 20 root canals). Was done the protocols of irrigation with NaOCL 5.25% and instrumentation, using files Protaper rotatory F3- F4, then the channels were obturados with cement AH Plus&reg;. After 180 days, the animals were euthanized, the pieces removed and submitted to histotechnical processing for immunohistochemical analysis for osteopontin, tumor necrosis factor-&alpha; and interleukin 1-&alpha;. Radiographic analysis of the repair of the periapical lesions was performed using the Periapical Index, obtained before and 180 days after the endodontic treatment. The results were submitted to statistical analysis using Fisher\'s exact test or Kruskal-Wallis test followed by Dunn\'s post-test. The level of significance was 5%. At 180 days after the endodontic treatment, the radiographic examination showed the persistence of periapical radiolucent areas and discontinuity of the lamina dura in 35% of the negative apical pressure group, 40% of the passive Ultrasonic Group specimens and 40% of the positive pressure Group specimens. However, when compared to radiographs prior to treatment, in all groups, a reduction in the size of periapical lesions was observed. There was no difference between the groups, regardless of the irrigation protocol used (p> 0.05). Endodontic treatment performed in a single session resulted in the lower synthesis of tumor necrosis factor-&alpha; and osteopontin in the periapical region, compared to untreated periapical lesion (p 0.05). The production of interleukin-1&alpha; was not modulated by endodontic treatment (p> 0.05). Based on the methodologies used and the results obtained in the present in vivo study, it was concluded that the periapical lesion was repaired in about 60% of cases after endodontic treatment performed in a single session and lower synthesis of tumor necrosis factor-&alpha; and osteopontin in the periapical region, compared to the untreated periapical lesion, regardless of the irrigation protocol used (negative apical pressure, passive ultrasonic and positive pressure)
129

Efficacy evaluation, through micro-CT, of reciprocating and rotary instruments followed by supplementary irrigant-agitation procedures in the retreatment of curved root canals / Avaliação, por meio da micro-CT, da eficácia de instrumentos reciprocantes e rotatórios seguidos por procedimentos suplementares de agitação de irrigantes no retratamento de canais radiculares curvos

Fruchi, Lincoln de Campos 15 August 2018 (has links)
Endodontic retreatments are time-consuming and difficult to perform. Removing the root canal filling material of the original treatment with maximum efficiency and safety is a complex task that requires a good technique, patience and perseverance. This filling material is often contaminated and prevents access to areas of the canal harboring bacteria and remnants of necrotic tissue, especially in the isthmus region and in dentinal tubules. The aim of this study was to use micro-computed tomography to evaluate two protocols for the removal of root canal filling material from curved root canals of the mesial roots of mandibular molars using a reciprocating instrument followed by two different rotary instruments manufactured with different nickel-titanium alloys. The reduction in the volume of the filling material inside the root canals was evaluated. Assessments were also made of the influence of the glide path extension on root canal obturation, the extrusion of filling material after the use of the reciprocating instrument, the volume of filling material after retreatment and its presence in isthmus areas. In addition, the use of a solvent and the agitation of a 2% sodium hypochlorite solution using either passive ultrasonic irrigation (PUI) or a plastic instrument in reciprocating motion were evaluated. A total of 40 mesial roots of mandibular molars with a mean curvature of 25 degrees were selected. The teeth were radiographed digitally in the buccolingual and mesiodistal directions, with a digital Xray system (Schick CDR; Schick Technologies, Long Island, NY), using an exposure time of 0.16 s. This was done in order to select the teeth and then compose two groups with similar characteristics to ensure their anatomic homogeneity. Group homogeneity in terms of anatomy, root canal length, curvature angle, and Vertucci classification type II and IV were confirmed and showed that the study groups were well balanced. Two groups were defined according to the retreatment protocol adopted, namely RHPui (Reciproc + Hyflex + PUI) and RMEasy (Reciproc + Mtwo + EasyClean). The teeth were instrumented with the Reciproc R25 instrument and filled using the single-cone technique and AHPlus cement. Prior to the use of this instrument, canal patency was achieved by creating a glide path with PathFile instruments, throughout the entire extension of the canal in Group RHPui, and up to 1 mm short of the total canal length in Group RMEasy. In both groups, the original filling material was removed with the Reciproc R25 instrument. Xylene was used as a solvent in Group RHPui up to the middle third, but not in the apical area, in the later steps of instrumentation with Reciproc R25. In Group RHPui, the Hyflex 40.04 instrument, made with a CM nickeltitanium alloy, was used. After that, xylene solvent was applied for one minute in the pulp chamber, followed by passive ultrasonic irrigation (PUI) with 2% sodium hypochlorite using an irrisonic instrument, applied up to 2 mm short of the working length. In Group RMEasy, the Mtwo 40.04 instrument, made with a conventional nickeltitanium alloy, was used. Xylene solvent was also used in the pulp chamber for one minute, followed by application of a 2% sodium hypochlorite solution agitated mechanically with an EasyClean plastic instrument in reciprocating motion up to the full working length. The two groups were re-obturated using the warm vertical condensation technique, with a gutta-percha cone corresponding to the final instrument, and with AHPus cement. Micro-CT scans were performed after each procedure to evaluate the volume of the remaining material, the extrusion after the use of the reciprocating instruments, the final volume of the obturation at the end of the retreatment and the filling material volume in the isthmus area, both after the original obturation and after re-obturation. The results showed that the initial filling was significantly closer to the apical foramen in Group RHPui than in Group RMEasy, after the initial treatment. After performing the retreatment protocols, the complete removal of filling material from inside the root canals was not achieved in either study group, with no statistically significant difference (P > 0.05) between groups regarding this variable. In the intra-group evaluation, a statistically significant difference (P < 0.05) was found between the procedural steps regarding the reduction in filling material volume, both in the total canal length and at its different levels, except for the middle third after HyFlex, the cervical third after Mtwo, and the middle third after EasyClean. The volume of the final filling material was significantly higher (P < 0.05) than the volume of the original filling material in both study groups. The volume of filling material in the isthmus region was significantly higher after re-obturation in both groups (P < 0.05), and this increase was greater in the RMEasy Group. There was no statistically significant difference (P > 0.05) between groups regarding the total amount of time expended in the removal of filling material (P > 0.05), namely 209.40 s for the RHPui Group and 227.40 s for the RMEasy Group. There was also no statistically significant difference (P > 0.05) between groups regarding the volume of extruded filling material, namely 0.0258 mm3 (0 0.954) in the RHPui Group and 0.0037 mm3 (0 0.565) in the RMEasy Group. The Shapiro-Wilks, Mann-Whitney, Wilcoxon, Friedman and Dunn tests were used in the data analysis. / Os retratamentos endodônticos demandam tempo e são difíceis de serem executados. Remover o material de obturação do tratamento original com a máxima eficiência e segurança é uma tarefa complexa que necessita de técnica, paciência e perseverança. Esse material de obturação muitas vezes está contaminado, e impede o acesso às áreas do canal onde permaneceram restos de tecido necrótico e microrganismos, especialmente na região do istmo e nos túbulos dentinários. O objetivo deste trabalho foi avaliar, por meio da microtomografia computadorizada, dois protocolos de desobturação de canais radiculares curvos de raízes mesiais de molares inferiores utilizando um instrumento reciprocante seguido de dois diferentes instrumentos rotatórios fabricados com diferentes ligas metálicas de níquel-titânio. Além da redução dos volumes de material obturador no interior dos canais, foram avaliados a influência do comprimento da patência do canal radicular (glide path) na obturação, extrusão de material obturador após o uso do instrumento reciprocante Reciproc R25, o volume do material de obturação após o retratamento e a presença deste em áreas de istmo. Também foi avaliado o uso de um solvente seguido da agitação do hipoclorito de sódio a 2% com ultrassom (PUI) e com um instrumento plástico acionado em movimento reciprocante. Foram selecionadas 40 raízes mesiais de molares inferiores com curvatura média de 25 graus que foram divididos em dois grupos de forma homogênea quanto ao comprimento, à curvatura e à anatomia (classes II e IV de acordo com a classificação de Vertucci) dos canais radiculares. Os dentes foram instrumentados com o instrumento Reciproc R25 e obturados com a técnica do cone único e com cimento AHPlus. Previamente ao uso do instrumento Reciproc R25, obteve-se a patência inicial do canal, ou seja, criou-se um glide path, com os instrumentos PathFile em toda a extensão do canal no Grupo RHPui e 1 mm aquém do comprimento total do canal no Grupo RMEasy. Os dois grupos foram definidos de acordo com o protocolo de retratamento adotado, a saber, RHPui (Reciproc + Hyflex + PUI) e RMEasy (Reciproc + Mtwo + EasyClean). Nos dois grupos, a remoção do material obturador original foi realizada com o instrumento Reciproc R25, sendo que no grupo RHPui foi utilizado o solvente xilol até a proximidade do terço médio, não sendo utilizado solvente no terço apical. No Grupo RHPui, utilizouse, então, o instrumento Hyflex 40.04 feito com liga de niquel-titânio CM (control memory ou de memória controlada) e, por último, utilizou-se o solvente xilol por um minuto na câmara pulpar, seguido de irrigação ultrassônica passiva (PUI) com solução de hipoclorito de sódio a 2% utilizando o instrumento Irrisonic, até o limite de 2 mm aquém do comprimento de trabalho. No Grupo RMEasy, foi utilizado o instrumento Mtwo 40.04 fabricado com liga de níquel-titânio convencional e, a seguir, também se utilizou o solvente xilol por um minuto na câmara pulpar seguido de uma agitação mecânica do hipoclorito de sódio a 2% com o instrumento plástico EasyClean em movimento reciprocante até o limite do comprimento total de trabalho. Os dois grupos foram re-obturados com a técnica de condensação vertical aquecida com cone de guta-percha correspondente ao instrumento final e com cimento AHPus. Foram realizadas microtomografias após cada procedimento para avaliar o volume de material remanescente, a extrusão após o uso dos instrumentos reciprocantes, o volume final da obturação ao final do retratamento e o volume na área de istmo, tanto após a obturação original quanto após a re-obturação. Os resultados obtidos mostraram que, no tratamento inicial, a patência do canal (ou glidepath) realizado com instrumentos Pathfile previamente ao uso dos instrumentos Reciproc R25 possibilitou que a obturação dos canais atingisse um limite significativamente (P < 0,05) mais próximo ao forame apical no grupo RHPui, onde o glidepath foi realizado em toda a extensão do canal. Em relação aos diferentes protocolos de retratamento, não houve remoção completa do material obturador do interior dos canais nos dois grupos estudados em todos os níveis avaliados, sem diferença estatisticamente significativa (P > 0,05) entre os grupos com relação a essa variável. Na avaliação intragrupo, houve uma diferença estatisticamente significativa (P < 0,05) entre os passos do procedimento em relação à redução do volume de material obturador, tanto na extensão total do canal, quanto nos seus diferentes níveis, com exceção do terço médio após o Hyflex, no terço cervical após o Mtwo e no terço médio após o EasyClean. O volume do material obturador final foi significativamente maior (P < 0,05) do que o volume do material obturador original, nos dois grupos estudados. O volume de material obturador na região do istmo foi significativamente maior (P < 0,05) após a re-obturação nos dois grupos, sendo significativamente maior (P < 0,05) no grupo RMEasy do que no grupo RHPui. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao tempo total despendido na remoção do material obturador (P > 0,05), sendo 209,40 s para o Grupo RHPui e 227,40 s para o Grupo RMEasy. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao volume da extrusão de material obturador, sendo 0,0258 mm3 (0 0,954) no Grupo RHPui e 0,0037 mm3 (0 0,565) no Grupo RMEasy. Os testes de Shapiro-Wilks, Mann- Whitney, Wilcoxon, Friedman e Dunn foram utilizados na análise dos dados.
130

Efficacy evaluation, through micro-CT, of reciprocating and rotary instruments followed by supplementary irrigant-agitation procedures in the retreatment of curved root canals / Avaliação, por meio da micro-CT, da eficácia de instrumentos reciprocantes e rotatórios seguidos por procedimentos suplementares de agitação de irrigantes no retratamento de canais radiculares curvos

Lincoln de Campos Fruchi 15 August 2018 (has links)
Endodontic retreatments are time-consuming and difficult to perform. Removing the root canal filling material of the original treatment with maximum efficiency and safety is a complex task that requires a good technique, patience and perseverance. This filling material is often contaminated and prevents access to areas of the canal harboring bacteria and remnants of necrotic tissue, especially in the isthmus region and in dentinal tubules. The aim of this study was to use micro-computed tomography to evaluate two protocols for the removal of root canal filling material from curved root canals of the mesial roots of mandibular molars using a reciprocating instrument followed by two different rotary instruments manufactured with different nickel-titanium alloys. The reduction in the volume of the filling material inside the root canals was evaluated. Assessments were also made of the influence of the glide path extension on root canal obturation, the extrusion of filling material after the use of the reciprocating instrument, the volume of filling material after retreatment and its presence in isthmus areas. In addition, the use of a solvent and the agitation of a 2% sodium hypochlorite solution using either passive ultrasonic irrigation (PUI) or a plastic instrument in reciprocating motion were evaluated. A total of 40 mesial roots of mandibular molars with a mean curvature of 25 degrees were selected. The teeth were radiographed digitally in the buccolingual and mesiodistal directions, with a digital Xray system (Schick CDR; Schick Technologies, Long Island, NY), using an exposure time of 0.16 s. This was done in order to select the teeth and then compose two groups with similar characteristics to ensure their anatomic homogeneity. Group homogeneity in terms of anatomy, root canal length, curvature angle, and Vertucci classification type II and IV were confirmed and showed that the study groups were well balanced. Two groups were defined according to the retreatment protocol adopted, namely RHPui (Reciproc + Hyflex + PUI) and RMEasy (Reciproc + Mtwo + EasyClean). The teeth were instrumented with the Reciproc R25 instrument and filled using the single-cone technique and AHPlus cement. Prior to the use of this instrument, canal patency was achieved by creating a glide path with PathFile instruments, throughout the entire extension of the canal in Group RHPui, and up to 1 mm short of the total canal length in Group RMEasy. In both groups, the original filling material was removed with the Reciproc R25 instrument. Xylene was used as a solvent in Group RHPui up to the middle third, but not in the apical area, in the later steps of instrumentation with Reciproc R25. In Group RHPui, the Hyflex 40.04 instrument, made with a CM nickeltitanium alloy, was used. After that, xylene solvent was applied for one minute in the pulp chamber, followed by passive ultrasonic irrigation (PUI) with 2% sodium hypochlorite using an irrisonic instrument, applied up to 2 mm short of the working length. In Group RMEasy, the Mtwo 40.04 instrument, made with a conventional nickeltitanium alloy, was used. Xylene solvent was also used in the pulp chamber for one minute, followed by application of a 2% sodium hypochlorite solution agitated mechanically with an EasyClean plastic instrument in reciprocating motion up to the full working length. The two groups were re-obturated using the warm vertical condensation technique, with a gutta-percha cone corresponding to the final instrument, and with AHPus cement. Micro-CT scans were performed after each procedure to evaluate the volume of the remaining material, the extrusion after the use of the reciprocating instruments, the final volume of the obturation at the end of the retreatment and the filling material volume in the isthmus area, both after the original obturation and after re-obturation. The results showed that the initial filling was significantly closer to the apical foramen in Group RHPui than in Group RMEasy, after the initial treatment. After performing the retreatment protocols, the complete removal of filling material from inside the root canals was not achieved in either study group, with no statistically significant difference (P > 0.05) between groups regarding this variable. In the intra-group evaluation, a statistically significant difference (P < 0.05) was found between the procedural steps regarding the reduction in filling material volume, both in the total canal length and at its different levels, except for the middle third after HyFlex, the cervical third after Mtwo, and the middle third after EasyClean. The volume of the final filling material was significantly higher (P < 0.05) than the volume of the original filling material in both study groups. The volume of filling material in the isthmus region was significantly higher after re-obturation in both groups (P < 0.05), and this increase was greater in the RMEasy Group. There was no statistically significant difference (P > 0.05) between groups regarding the total amount of time expended in the removal of filling material (P > 0.05), namely 209.40 s for the RHPui Group and 227.40 s for the RMEasy Group. There was also no statistically significant difference (P > 0.05) between groups regarding the volume of extruded filling material, namely 0.0258 mm3 (0 0.954) in the RHPui Group and 0.0037 mm3 (0 0.565) in the RMEasy Group. The Shapiro-Wilks, Mann-Whitney, Wilcoxon, Friedman and Dunn tests were used in the data analysis. / Os retratamentos endodônticos demandam tempo e são difíceis de serem executados. Remover o material de obturação do tratamento original com a máxima eficiência e segurança é uma tarefa complexa que necessita de técnica, paciência e perseverança. Esse material de obturação muitas vezes está contaminado, e impede o acesso às áreas do canal onde permaneceram restos de tecido necrótico e microrganismos, especialmente na região do istmo e nos túbulos dentinários. O objetivo deste trabalho foi avaliar, por meio da microtomografia computadorizada, dois protocolos de desobturação de canais radiculares curvos de raízes mesiais de molares inferiores utilizando um instrumento reciprocante seguido de dois diferentes instrumentos rotatórios fabricados com diferentes ligas metálicas de níquel-titânio. Além da redução dos volumes de material obturador no interior dos canais, foram avaliados a influência do comprimento da patência do canal radicular (glide path) na obturação, extrusão de material obturador após o uso do instrumento reciprocante Reciproc R25, o volume do material de obturação após o retratamento e a presença deste em áreas de istmo. Também foi avaliado o uso de um solvente seguido da agitação do hipoclorito de sódio a 2% com ultrassom (PUI) e com um instrumento plástico acionado em movimento reciprocante. Foram selecionadas 40 raízes mesiais de molares inferiores com curvatura média de 25 graus que foram divididos em dois grupos de forma homogênea quanto ao comprimento, à curvatura e à anatomia (classes II e IV de acordo com a classificação de Vertucci) dos canais radiculares. Os dentes foram instrumentados com o instrumento Reciproc R25 e obturados com a técnica do cone único e com cimento AHPlus. Previamente ao uso do instrumento Reciproc R25, obteve-se a patência inicial do canal, ou seja, criou-se um glide path, com os instrumentos PathFile em toda a extensão do canal no Grupo RHPui e 1 mm aquém do comprimento total do canal no Grupo RMEasy. Os dois grupos foram definidos de acordo com o protocolo de retratamento adotado, a saber, RHPui (Reciproc + Hyflex + PUI) e RMEasy (Reciproc + Mtwo + EasyClean). Nos dois grupos, a remoção do material obturador original foi realizada com o instrumento Reciproc R25, sendo que no grupo RHPui foi utilizado o solvente xilol até a proximidade do terço médio, não sendo utilizado solvente no terço apical. No Grupo RHPui, utilizouse, então, o instrumento Hyflex 40.04 feito com liga de niquel-titânio CM (control memory ou de memória controlada) e, por último, utilizou-se o solvente xilol por um minuto na câmara pulpar, seguido de irrigação ultrassônica passiva (PUI) com solução de hipoclorito de sódio a 2% utilizando o instrumento Irrisonic, até o limite de 2 mm aquém do comprimento de trabalho. No Grupo RMEasy, foi utilizado o instrumento Mtwo 40.04 fabricado com liga de níquel-titânio convencional e, a seguir, também se utilizou o solvente xilol por um minuto na câmara pulpar seguido de uma agitação mecânica do hipoclorito de sódio a 2% com o instrumento plástico EasyClean em movimento reciprocante até o limite do comprimento total de trabalho. Os dois grupos foram re-obturados com a técnica de condensação vertical aquecida com cone de guta-percha correspondente ao instrumento final e com cimento AHPus. Foram realizadas microtomografias após cada procedimento para avaliar o volume de material remanescente, a extrusão após o uso dos instrumentos reciprocantes, o volume final da obturação ao final do retratamento e o volume na área de istmo, tanto após a obturação original quanto após a re-obturação. Os resultados obtidos mostraram que, no tratamento inicial, a patência do canal (ou glidepath) realizado com instrumentos Pathfile previamente ao uso dos instrumentos Reciproc R25 possibilitou que a obturação dos canais atingisse um limite significativamente (P < 0,05) mais próximo ao forame apical no grupo RHPui, onde o glidepath foi realizado em toda a extensão do canal. Em relação aos diferentes protocolos de retratamento, não houve remoção completa do material obturador do interior dos canais nos dois grupos estudados em todos os níveis avaliados, sem diferença estatisticamente significativa (P > 0,05) entre os grupos com relação a essa variável. Na avaliação intragrupo, houve uma diferença estatisticamente significativa (P < 0,05) entre os passos do procedimento em relação à redução do volume de material obturador, tanto na extensão total do canal, quanto nos seus diferentes níveis, com exceção do terço médio após o Hyflex, no terço cervical após o Mtwo e no terço médio após o EasyClean. O volume do material obturador final foi significativamente maior (P < 0,05) do que o volume do material obturador original, nos dois grupos estudados. O volume de material obturador na região do istmo foi significativamente maior (P < 0,05) após a re-obturação nos dois grupos, sendo significativamente maior (P < 0,05) no grupo RMEasy do que no grupo RHPui. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao tempo total despendido na remoção do material obturador (P > 0,05), sendo 209,40 s para o Grupo RHPui e 227,40 s para o Grupo RMEasy. Não houve diferença estatística (P > 0,05) entre os grupos com relação ao volume da extrusão de material obturador, sendo 0,0258 mm3 (0 0,954) no Grupo RHPui e 0,0037 mm3 (0 0,565) no Grupo RMEasy. Os testes de Shapiro-Wilks, Mann- Whitney, Wilcoxon, Friedman e Dunn foram utilizados na análise dos dados.

Page generated in 0.1365 seconds