• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • 5
  • 5
  • 5
  • 5
  • 4
  • 1
  • Tagged with
  • 63
  • 63
  • 37
  • 16
  • 15
  • 15
  • 12
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo

Martins Júnior, José Roberto Severino [UNESP] 23 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-23Bitstream added on 2014-06-13T19:18:57Z : No. of bitstreams: 1 martinsjunior_jrs_me_bauru.pdf: 3438842 bytes, checksum: c98511273a55e7af07b24dd5b19c844f (MD5) / Desde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatível / Since 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatible
62

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo /

Martins Júnior, José Roberto Severino. January 2010 (has links)
Orientador: Carlos Roberto Grandini / Banca: Marize Varella de Oliveira / Banca: Nilson Tadeu Camarinho de Oliveira / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Desde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatível / Abstract: Since 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatible / Mestre
63

[pt] ESTUDO DA INFLUÊNCIA DE TRATAMENTOS TÉRMICOS E DE ADITIVOS NAS PROPRIEDADES ÓPTICAS DE POLÍMEROS CONJUGADOS UTILIZADOS PARA CÉLULAS SOLARES ORGÂNICAS / [en] STUDY OF THE INFLUENCE OF THERMAL TREATMENTS AND ADDITIVES ON THE OPTICAL PROPERTIES OF CONJUGATED POLYMERS USED FOR ORGANIC SOLAR CELLS

LEONARDO GARCIA FERNANDEZ 12 August 2021 (has links)
[pt] Este trabalho teve como objetivo comparar as diferentes influências que aditivos e tratamentos térmicos têm sobre as propriedades ópticas e elétricas de filmes finos semicondutores formados por polímeros contendo principalmente bitiofenos e fluorenos. Os polímeros contendo tiofenos em sequência, como o poli[(9,9-dioctilfluorenil-2,7-diil)co-bitiofeno] (F8T2), apresentam conformações cis e trans dependente da posição relativa dos átomos de enxofre, tendo suas propriedades alteradas de acordo com a proporção entre os domínios de ambas as conformações em um mesmo filme. Os átomos de iodo presentes no aditivo 1,8- diiodooctano são tidos como uma possível forma de alterar os agregados nesse polímero e, consequentemente, alterar as propriedades físicas do filme formado. Para aumentar o entendimento sobre os átomos diferentes de carbono e hidrogênio nos aditivos foram estudados os efeitos dos aditivos 1,8-diiodooctano, 1,8- octanoditiol e octano, que contém dois iodos, dois enxofres e não contém heteroátomos, respectivamente, em sua composição. Além disso, foi estudada a introdução do polímero PMMA (polimetilmetacrilato) de forma que alterasse a estrutura interna do filme fino e também foram estudados tratamentos térmicos em diferentes temperaturas, uma vez que parâmetros como tempo de evaporação do solvente também influenciam a formação e as propriedades do filme após seu crescimento. Outro ponto de interesse foi justamente a composição dos polímeros, para tal, foram estudados, além do F8T2, os polímeros poli(9,9-dioctilfloureno) (PFO), poli(9,9-dioctilfluoreno-cobenzotiadiazol) (F8BT) e poli(3-hexiltiofeno-2,5-diil) regiorregular (rrP3HT). Eles são formados, respectivamente, por bitiofenos e fluorenos, apenas fluorenos, fluorenos e benzotiadiazol e apenas politiofenos. Dessa forma, seria possível isolar as contribuições de cada grupo isolado e combinados com grupos que permitem ou não a mudança entre conformações. Os filmes foram depositados em substratos de vidro pela técnica de spin-coating e a caracterização foi feita com medidas de absorção, fotoluminescência e FTIR. Quando possível, foram realizadas medidas CELIV e corrente-tensão de dispositivos fotovoltaicos usando os polímeros como camada doadora de elétrons. Com este trabalho foi possível variar as intensidades dos picos de absorção e alterar o gap de energia dos polímeros. Destacando a ação do DIO, observou-se que a conformação cis do F8T2 é maximizada quando se utiliza 1 por cento do aditivo. Além disso, o DIO também aumenta a porcentagem de fase beta do PFO. Já para o P3HT, foi constatado um aumento no ordenamento do filme. / [en] This work aimed to compare the different influences that additives and heat treatments have on the properties of semiconductor thin films formed by polymers containing mainly bitiophenes and fluorenes. Polymers containing thiophenes in sequence, such as poly[(9,9-dioctylfluorene-2,7-diyl)co-bithiophene] (F8T2), have cis and trans conformations depending on the relative position of the sulfur atoms, having their optical and electrical properties altered according to the proportion between the domains of both conformations in the same film. The iodine atoms present in the additive 1,8-diiodooctane are considered as a possible way to change the aggregates in this polymer and, consequently, change the physical properties of the formed film. To increase the understanding of the atoms other than carbon and hydrogen in the additives, the effects of the additives 1,8-diiodooctane, 1,8- octanodithiol and octane, which contain two iodines, two sulfur and do not contain heteroatoms, respectively, were studied. In addition, the introduction of the PMMA (polymethylmethacrylate) polymer was studied in order to alter the internal structure of the thin film and, also, heat treatments at different temperatures were studied, since parameters such as solvent evaporation time and the available thermal energy also influence the formation and properties of the film after its growth. Another point of interest was precisely the composition of the polymers. For this purpose, in addition to F8T2, the polymers poly(9,9-dioctylflourene) (PFO), poly(9,9-dioctylfluorene-cobenzothiadiazole) (F8BT) and regioregular poly(3- hexylthiophene-2,5-diyl) (rrP3HT) were studied. They are formed, respectively, by bitiophenes and fluorenes, only fluorenes, fluorenes and benzothiadiazole and only polythiophenes. In this way, it would be possible to isolate the contributions of each isolated and combined groups that allow or not to change between conformations. The films were deposited on glass substrates using the spin-coating technique and the characterization was done via absorption, photoluminescence and FTIR measurements. When possible, CELIV and current-voltage measurements of photovoltaic devices were performed using the polymers as an electron donor layer. With this work it was possible to vary the intensities of the absorption peaks and to change the energy gap of the polymers. Highlighting the action of DIO, it was observed that the cis conformation of F8T2 is maximized when 1 percent of the additive is used. In addition, DIO also increases the percentage of beta phase of PFO. For P3HT, on the other hand, there was an increase in the ordering of the film.

Page generated in 0.3486 seconds