121

Estudo da codisposição de resíduos de fossas e tanques sépticos, com e sem a remoção prévia de gordura, no desempenho de tratamento de esgoto com reatores UASB / Codisposição study of waste and seotic tanks e repair, with and without prior removal of fat in the performance of sewage treatment with UASB reactors

Peixoto, Aline Vieira 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-08T18:01:37Z No. of bitstreams: 1 Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-08T20:24:04Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:33:30Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:22:47Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Made available in DSpace on 2014-12-16T09:22:49Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) Previous issue date: 2013-07-15 / In Brazil, according to a national survey conducted by the Brazilian Institute of Geography and Statistics (IBGE, 2010), 44.8% of the municipalities use simplified domestic waste treatment systems such as septic tanks, rudimentary cesspools and dry pits. Such systems lead to the production of potentially polluting waste which requires suitable co-treatment. Several co-treatment alternatives have been proposed. The present study, which is part of the Program on Basic Sanitation Research (PROSAB), aimed to evaluate the interference caused by septage disposal from cesspools and septic tanks on the performance of the Upflow Anaerobic Sludge Blanket Reactor (UASB) in the city of Itumbiara- Goiás. The study took nine months and was divided into three distinct phases, in which the volumetric flow rate of wastewater from cesspools and septic tanks into the reactor ranged from 0.17% to 0.51%, displaying an intermediate phase of 0.34%.In the third phase, another fat flotation phase was added to the pre-treatment prior to discharge. During the study, we utilized all the waste volume from cesspools and septic tanks produced by the municipality and discharged into the Itumbiara Wastewater Treatment Plant (WWTP), already working at its full capacity. Statistical tests have proved that wastes from cesspool and septic tanks disposed into UASB reactors showed no significant difference in the final effluent quality. It was not evidenced also significant differences in the operation and maintenance of the reactors. The biological sludge from the UASB reactors got stable after being added the wastes (ratio VS/TS between 0.53 and 0.58 average). The receiving reactor’s begs had a worse efficiency but statistical tests showed that the difference was not significant when compared to the control reactors. It was observed in this study, there is no need for the pre-flotation of waste before being released at WWTP with UASB system. Thus the UASB is a viable alternative, but it is necessary to follow a protocol to establish criteria such as the waste application rate, the WWTP site for waste discharge, physical structure and people, as well as to choose for relevant parameters for the waste monitoring before co-treatment. / No Brasil, segundo Pesquisa Nacional de Saneamento Básico do Instituto Brasileiro de Geografia e Estatística (IBGE, 2010), 44,8% dos municípios utilizam sistemas simplificados para tratamento dos esgotos domésticos como: tanques sépticos, fossas rudimentares, fossas secas. Estes sistemas têm como consequência a produção de resíduos com potencial poluidor que necessitam de codisposição adequada. Diferentes alternativas de codisposição têm sido propostas. O presente trabalho, inserido na rede de pesquisa do Programa de Pesquisas em Saneamento Básico (PROSAB), tem como objetivos avaliar as interferências da disposição de resíduos de fossas e tanques sépticos no desempenho do Reator Anaeróbio de Manta de Lodo de fluxo ascendente ou Upflow Anaerobic Sludge Blanket (UASB), na cidade de Itumbiara-Goiás. O estudo teve duração de nove meses e foi dividido em três fases distintas, alterando a taxa de aplicações volumétrica dos resíduos de fossas e tanques sépticos no reator que variou de 0,17% a 0,51%, tendo uma fase intermediária de 0,34%, além de, na terceira fase, acrescentar mais uma etapa de flotação da gordura no tratamento preliminar, antes do lançamento dos resíduos. Durante a pesquisa, foi utilizado todo o volume de resíduos de fossas e tanques sépticos gerados pelo município e dispostos na ETE de Itumbiara que já trabalha com a carga máxima. Testes estatísticos comprovaram que a disposição de resíduos de fossas e tanques sépticos nos reatores UASB não apresentou diferença significativa na qualidade do efluente. Também não foram comprovadas alterações significativas na operação e manutenção dos reatores. O lodo biológico dos reatores UASB apresentou estabilidade após a disposição dos resíduos (relação SV/ST entre 0,53 a 0,58 em média). Os leitos do reator receptor apresentaram pior eficiência, porém testes estatísticos comprovaram que a diferença não foi significativa quando comparado com reatores testemunhos. Foi observou neste estudo, que não há necessidade da flotação prévia dos resíduos antes de serem lançados nas ETEs com sistema UASB. Portanto o UASB é uma alternativa viável, porém é necessário seguir um protocolo com critérios que estabelecerá a taxa de aplicação dos resíduos, o local na ETE onde será lançado o resíduo, estrutura física e de pessoal da ETE e determinar parâmetros de relevância para o monitoramento dos resíduos antes da codisposição.
122

Tratamento AnaerÃbio do LÃquido da Casca de Coco Verde / Anaerobic treatment of Coconut Husk Liquor (CHL)utilizing UASB reactor.

Alex Miranda de AraÃjo 21 February 2008 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Para promover o reuso de resÃduos da agroindÃstria e agregar valor à cadeia produtiva do coco verde, a Embrapa agroindÃstria tropical desenvolveu uma tecnologia capaz de aproveitar cascas deste produto. Atualmente, as cascas do coco verde compÃem a maior parte dos resÃduos sÃlidos depositados nas praias. A tecnologia converte as cascas em pà e fibra que possuem grandes aplicaÃÃes comerciais e ambientais. Durante a etapa de prensagem, ocorre a geraÃÃo do LÃquido da Casca de Coco Verde (LCCV), que apresenta elevada concentraÃÃo de matÃria orgÃnica, cuja Demanda QuÃmica de OxigÃnio (DQO) varia de 60 a 80 gO2/L, incluindo compostos fenÃlicos e aÃucares. Neste trabalho, avaliou-se a performance de um reator anaerÃbio de fluxo ascendente e manta de lodo (Upflow Anaerobic Sludge Blanket â UASB) para tratamento do LCCV. O reator UASB em escala de laboratÃrio (16,8 L) foi operado por 222 dias tendo sua carga orgÃnica volumÃtrica (COV) aumentada gradativamente de 2,2 atà 10 Kg DQO/ m3 d. A performance do UASB foi avaliada atravÃs de determinaÃÃes de DQO, compostos fenÃlicos totais (taninos) do afluente e efluente; atividade metanogÃnica especÃfica (AME) e toxicidade anaerÃbia do lodo; composiÃÃo e produÃÃo de biogÃs; pH, alcalinidade e Ãcidos graxos volÃteis (AGV). Os resultados demonstraram que o UASB pode ser usado para prÃ-tratamento do LCCV, mantendo-se estÃvel durante toda a operaÃÃo do sistema com remoÃÃo de DQO superior a 80% e de taninos em torno de 48%. A razÃo AGV/alcalinidade bicarbonato ficou sempre inferior a 0,40. O biogÃs apresentou composiÃÃo de 75% de metano. Os ensaios de toxicidade demonstraram que o LCCV nÃo foi tÃxico à biomassa metanogÃnica presente no UASB. / With the aim of reusing the agroindustry waste and aggregating value to the productive chain of immature coconut, Embrapa AgroindÃstria Tropical (Brazilian Agricultural Research Corporation, Tropical Agroindustry National Centre) has developed a system for processing this raw material. During the pressing stage, the Coconut Husk Liquor (CHL) is generated. It contains high concentration of organic matter, with Chemical Oxygen Demand (COD) varying from 60 to 80 g/L, including phenolic compounds and sugars. In this work, the performance of an Upflow Anaerobic Sludge Blanket Reactor (UASB) was evaluated for CHL treatment. The lab-scale UASB reactor (16.8 L) was operated during 222 days increasing the organic loading rate (OLR) from 2.2 kgCOD/m3.d to 10 kgCOD/m3.d. The UASB reactor performance was evaluated based on influent and effluent COD and total phenolic compounds (tannin); sludge specific methanogenic activity (SMA) and anaerobic toxicity; biogas production and composition; pH, alkalinity and volatile fatty acids (VFA). Results showed that UASB reactor can be used for pre-treatment of CHL, showing stability during the operation period, with COD removal efficiency higher than 80%, phenolics compounds removal efficiency of around 48%. The ratio AGV/alkalinity was always lower than 0,30. Biogas presented 75% of methane on its composition. Toxicity tests demonstrated that CHL was not toxic to the methanogenic consortia.
123

Coagulação, floculação e flotação do efluente de reatores anaeróbios, tratando esgoto sanitário, com aplicação de diferentes dosagens de coagulante em função da variação da turbidez do esgoto afluente ao longo do dia / Coagulation, flocculation and flotation of anaerobic reactor effluents, treating sewage with the employment of different amounts of coagulant, according to the variation in sewage turbidity throughout the day

Gustavo Carneiro Ariano 11 September 2009 (has links)
Este trabalho avaliou a técnica de dosagem variável de coagulante em função da variação da turbidez do esgoto afluente a sistema de pós-tratamento por flotação do efluente de reatores UASB, localizado em Campinas, SP. Utilizou-se equipamento do tipo Flotateste para a flotação em escala de laboratório, sendo fixados os parâmetros: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Foram estudadas quatro velocidades de flotação (Vf), entre 8 à 20 cm/min. Na fase 1 da pesquisa estudou-se os coagulantes \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'Cl IND.3\', sendo determinadas as melhores dosagens para o horário das 12:00 horas. Posteriormente, na segunda fase, foram fixadas as melhores dosagens de cada coagulante e associada dosagens variadas de polímeros catiônico, aniônico e não iônico. Em seguida, na fase 3, foi realizada avaliação temporal, com ensaios realizados em seis diferentes horários do dia, estabelecendo uma razão entre a variação da turbidez afluente com a dosagem de coagulante. Finalmente, na quarta fase, foram aplicados quatro cenários de dosagens em doze horários diferentes ao longo de 24 horas. Para fase 1, verificou-se remoção de SST, DQO e fósforo para as dosagens de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77mg \'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% e 63,9%; PAC (8,45 mg \'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% e 82,7%; e \'FE\'CL IND.3\' (24,38 mg\'FE\'/L), 60,0%; 55,9% e 90,3%, respectivamente, para Vf = 16 cm/min. Na fase 2, determinou-se como melhor polímero, para ambos coagulantes, o polímero catiônico (PC), sendo associado às melhores dosagens definidas na fase1. Desta maneira na fase 2 verificou-se remoção de SST, DQO e fósforo para as dosagens associadas de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% e 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% e 88,8%; e \'FE\'CL IND.3\' + PC (24,38 mg\'FE\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectivamente. O cloreto férrico foi escolhido para ser utilizado nas fases seguintes devido a capacidade de precipitação de sulfeto o qual atingiu concentrações de até 15 mg/L no efluente anaeróbio. Em adição, foram fixadas as dosagens de polímero catiônico em 1,00 mg/L. Assim, para fase 3, a aplicação de dosagem variada entre 12,07 a 25,51 mg\'FE\'/L, para seis diferentes horários resultou em DQO < 50 mg/L e Fósforo < 0,50 mg/L para Vf = 16 cm/min. A aplicação de razão entre a dosagem de \'FE POT.+3\' e a turbidez afluente (RDmT) de 0,463 mg\'FE POT.+3\'/L.UNT (para turbidez < 50 UNT) e 0,244 mg\'FE POT.+3\'/L.UNT (para turbidez >50 UNT) na fase 4, garantiu para todas as velocidades de flotação estudadas turbidez < 15 UNT em 100% dos ensaios. Em adição, ao se realizar correlação entre a concentração de SST no efluente da FAD e a turbidez, chegou-se a conclusão de que este cenário atingiu remoção de lodo próxima a dosagem de \'FE\'CL IND.3\' máxima definidas na fase 3 (74 mg\'FE\'CL IND.3\'/L), com economia de 27,8% no consumo do coagulante. / This study evaluated the variable coagulant dosage technique according to the variation in turbidity of the influent sewage of the post-treatment flotation system of the UASB reactor effluents, located in Campinas, SP. Laboratory scale flotation equipment was used, with fixed parameters: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Four flotation velocities (Vf), between 8 a 20 cm/min, were studied. Phase 1 of the research studied the coagulants \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'CL IND.3\', being determined the best dosages for 12:00 pm. In phase 2 the best dosages of each coagulant were fixed and the associated cationic, anionic and nonionic polymer dosages were varied. In phase 3 experiments were taken at six different periods of the day, establishing a ratio between the variation in influent turbidity and coagulant dosage. In the fourth phase, four different dosage scenarios were applied at twelve different periods during a 24 hour day, to verify the best dosage scenario. In phase 1, the removal of TSS, COD and phosphorus was verified to the dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77 mg\'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% and 63,9%; PAC (8,45 mg\'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% and 82,7%; and \'FE\'CL IND.3\' (24,38 mg\'FE POT.+3\'/L), 60,0%; 55,9% e 90,3%, respectively, for Vf = 16 cm/min. In phase 2 the cationic polymer (PC) was determined to be the best polymer for both coagulants, when applied to the best dosages determined in phase 1. This way, in phase 2 the removal of TSS, COD and phosphorus was verified to the associated dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% and 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% and 88,8%; and \'FE\'CL IND.3\' + PC (24,38 mg\'FE POT.+3\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectively. Ferric chloride was chosen in the following phases due to its sulfide precipitation ability, reaching concentrations of up to 15 mg/L in the anaerobic effluent. In addition, the cationic polymer dosages were fixed to 1,00 mg/L. Thus, in phase 3, the dosage, varying between 12,07 to 25,51 mg\'FE POT.+3\'/L, applied to six different periods resulted, to Vf = 16 cm/min, in COD < 50 mg/L and phosphorus < 0,50 mg/L. The ratio between the dosage of \'FE POT.+3\' and the influent turbidity (RDmT) of 0,463 mg\'FE POT.+3\'/L.UNT (for turbidities < 50 NTU) and 0,244 mg\'FE POT.+3\'/L.UNT (for turbidities \'< OU =\' 50 NTU) when applied in phase 4, ensured, in 100% of the experiments, turbidity < 15 NTU for the studied flotation velocities. In addition, when correlating the concentration of TSS in FAD effluents with the turbidity, the conclusion was that this scenario reached a sludge removal close to that obtained by the maximum \'FE\'CL IND.3\' dosage defined in phase 3 (74 mg\'FE\'CL IND.3\'/L), with an economy of 27,8% in coagulant consumption.
124

Resposta dinâmica dos reatores UASB (Upflow Anaerobic Sludge Blanket) submetidos a cargas orgânicas e hidráulicas cíclicas: modelação matemática simplificada / Dynamic behavior of the UASB (Upflow Anaerobic Sludge Blanket) reactors submitted to organic and hydraulic cyclical loads: mathematical modeling simplified

Karina Querne de Carvalho 10 June 2002 (has links)
Em países com condições ambientais, sócio-culturais e econômicas favoráveis à aplicação de processos anaeróbios para tratamento de esgotos sanitários, o reator UASB (Upflow Anaerobic Sludge Blanket) possui muitas vantagens, dentre os reatores anaeróbios, por permitir instalação, operação e manutenção a baixos custos, apresentar baixa geração de lodo, ser capaz de suportar sobrecargas hidráulicas e orgânicas e possuir eficiência de remoção de demanda química de oxigênio entre 70% e 80%. Contudo poucos estudos são reportados na literatura quando o reator é submetido a variações cíclicas diárias, de cargas orgânicas e hidráulicas, em períodos curtos de duração - iguais ou menores que 24 h. Para compreender os prováveis amortecimentos e atrasos nas respostas de reatores UASB quando submetidos a essas variações, desenvolveu-se um modelo matemático simplificado baseado no regime de escoamento contínuo de um tanque de mistura completa, no modelo cinético tipo Monod para remoção de DQO (Demanda Química de Oxigênio) e equacionamentos empíricos reportados na literatura. Esse modelo indicou que, mesmo apresentando baixa eficiência na remoção de demanda química de oxigênio, o reator possui capacidade de amortecer as variações impostas de vazão e respondeu com grande sensibilidade à variação de velocidade específica máxima de degradação de substrato, indicando que esse parâmetro cinético deve ser o parâmetro de calibração do modelo matemático. / In countries with favorable environmental, social, cultural and economical conditions, the use of anaerobic processes in treatment of domestic sewage. The UASB reactor (Upflow Anaerobic Sludge Blanket) has many advantages, among the anaerobic reactors, allows the installation, operation and maintenance with low costs; presents low sludge generation; is capable to support organic and hydraulic overloads and has COD removal efficiencies between 70% and 80%. However few studies are reported in the literature about reactors submitted to cyclical daily variations of organic and hydraulic loads in short periods of time - equal to or shorter than 24 hours. Aiming to understand the probable dampening and the delays in the response of the UASB reactors when submitted to these variations, it was developed a simplified mathematical model based on the continuous flow pattern of a completed stirred tank and in the Monod kinetic model for COD (Chemical Oxygen Demand) removal and empirical kinetic equations reported in the literature. The model indicated that, even when presenting low efficiency in the removal of COD, the reactor has a capacity to dampen the forced flow variations, and responded with great sensivity to the variation of qmáx., indicating that this kinetic parameter may be the calibration parameter of the mathematical model.
125

Resposta dinâmica de reator UASB em escala piloto submetido a cargas orgânicas e hidráulicas cíclicas: modelos matemáticos e resultados experimentais / Dynamic response of a UASB reactor submitted to organic and hydraulic cyclical loads: mathematical models and experimental results

Karina Querne de Carvalho 14 December 2006 (has links)
Poucos estudos são reportados na literatura sobre o comportamento dinâmico do reator UASB submetido a variações cíclicas diárias, de cargas orgânicas e hidráulicas, em períodos curtos de duração - iguais ou menores que 24h, com os quais verifica-se queda na eficiência do reator, causada pela provável flotação dos grânulos, problemas com geração de odor e alta concentração de sólidos suspensos no efluente. Para melhor compreender a resposta dinâmica desses reatores submetidos a essas variações, foi desenvolvido o modelo MMS baseado no modelo hidrodinâmico de mistura completa em reatores em série, modelo cinético de primeira ordem para consumo de substrato e para crescimento da biomassa e equacionamentos empíricos reportados na literatura. Esse modelo indicou a capacidade do reator de amortecer as variações impostas e a influência da cinética na eficiência de remoção da matéria orgânica. Para calibrar e validar o MMS, foi avaliado o desempenho de um reator UASB (160 L) no tratamento de esgoto sanitário municipal da cidade de São Carlos. Durante o período de operação, o reator foi submetido a variações senoidais cíclicas, de cargas orgânica e hidráulica, em valores inferiores e superiores a 40% e 60% da vazão afluente de 16,0 L/h. A produção média de gás metano e a eficiência média de remoção de DQO alcançadas pelo reator foram de aproximadamente: 1,83 L/h e 61% para vazão afluente de 16 L/h, TDH de 10 h e velocidade ascensional de 0,23 m/h; 2,24 L/h e 48% para variação cíclica de 40% e 2,97 L/h e 40% para variação cíclica de 60%. O MMS indicou faixa de valores para a DQO efluente com diferença em relação aos resultados observados experimentalmente - de 37% para vazão afluente constante de 16 L/h e 59% e 56% para variações senoidais cíclicas de 40% e 60% da vazão afluente, respectivamente – devido à limitação do modelo em considerar o arraste de sólidos no efluente que ocorreu ao longo de toda a operação do reator e mais acentuadamente quando foram aplicadas variações da vazão afluente. O modelo ADM1 proposto por Batstone et al.(2002a,b)apresentou menor similaridade com os resultados observados experimentalmente por não contemplar a variação horária e diária de alguns parâmetros de entrada, mas apenas a média aritmética dos valores. / There are no extensive reports on the dynamic behaviour of UASB reactor submitted to cyclical daily variations of organic and hydraulic loads of short periods of time - equal to or shorter than 24 hours - that can damage the reactor efficiency due to probable granule flotation, odor generation and high concentration of suspended solids in the effluent. Aiming to understand the dynamic response of these reactors when submitted to these variations, it was developed the MMS model based on the N-continuous flow stirred tank reactors (CSTR) in series model, first order kinetics model for substrate consumption and biomass growth and empirical equations reported in the literature. The model indicated the reactor capacity on dampening the imposed flow rate variations and the influence of the kinetics in the organic matter removal efficiency. It was evaluated the response of a UASB in bench scale (160 L) treating sanitary sewage of São Carlos city in order to calibrate and validate the MMS. During the operation, the reactor was submitted to cyclical sinusoidal variations of organic and hydraulic loads in lesser and higher values of 40% and 60% of the influent flow rate of 16 L/h. The reactor achieved mean methane production and mean COD removal efficiency of: 1,83 L/h and 61% to influent flow rate of 16 L/h, HRT of 10 h and upflow velocity of 0,23 m/h; 2,24 L/h and 48% to sinusoidal variation of 40%; 2,97 L/h and 40% to sinusoidal variation of 60%. The MMS model results indicated a range of effluent COD values with a difference of 37% to influent flow rate of 16 L/h, 59% and 56% to sinusoidal variations of 40% and 60%, respectively, in comparison with the experimental observed data. This probably occurred due to the model limitation in considering and predicting the solids washout in the effluent that was verified during all the operation, and also more significant when the sinusoidal variations were applied. The ADM1 reported by Batstone et al. (2002a,b) presented lesser similarity with the experimental observed results due to the fact that it does not consider hourly and daily variations of some input parameters, but only the arithmetical mean of the values.
126

Reator anaeróbio híbrido para tratamento de esgoto sanitário / Hybrid anaerobic reactor for domestic sewage treatment

Fernando Hermes Passig 11 March 2005 (has links)
Este trabalho de investigação refere-se ao uso do reator anaeróbio híbrido para tratamento de esgoto sanitário, com configuração baseada no reator anaeróbio de manta de lodo (UASB) com inclusão de: meio suporte sobre as calhas de coleta de gás (denominado reator anaeróbio híbrido - UAHB) e, também, meio suporte na zona de reação (denominado reator anaeróbio híbrido modificado - UAHBmod). Para o desenvolvimento desta pesquisa, no Campus I da USP de São Carlos-SP foram construídos dois reatores experimentais de 18,8 m3 cada: um reator UASB, com função de controle, e um reator UAHB. Primeiramente os reatores foram operados por período de 200 dias, com tempo de detenção hidráulica (TDH) de 6 h. Após serem inoculados, com 80 dias de operação, os reatores atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média de DQO, de 84% e 85% e de DBO de 87% e 91%, respectivamente para o UASB e o UAHB. Após esse período, os reatores foram submetidos a aumento da velocidade ascensional (Vasc) (mediante recirculação do efluente) de 0,78 m.h-1; 1,17 m.h-1; 1,56 m.h-1 e de 1,96 m.h-1. O UAHB mostrou ser menos susceptível ao aumento da Vasc do que o UASB. Além da análise da operação dos reatores, foram realizados os ensaios hidrodinâmicos e avaliada a estrutura da comunidade microbiana, por microscopia ótica, epifluorescência e pela técnica do DGGE. Após esse período preliminar, os reatores UAHB e UAHBmod, operados com TDH de 6h e Vasc de 0,78 m.h-1, atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média da matéria orgânica, de 71% e 76% em DQO, e de 72% e 87% em DBO, respectivamente para o UAHB e UAHBmod. Após este período, o reator UAHBmod, submetido a Vasc de 1,56 m.h-1, promoveu remoção de 74% de DQO, e de 87% de DBO. / This research refers to the use of a hybrid anaerobic reactor (UAHB) for domestic wastewater treatment. The configuration of this reactor is based on a sludge bed anaerobic reactor (UASB); in the first instance, a media support above the gas collection apparatus (also known as hybrid anaerobic reactor) was provided and later, a media support on the reaction zone (also known as hybrid modified anaerobic reactor - UAHBmod) was provided. Two reactors, with a volume of 18.8 m3, each, were built for this research at Campus I, USP in São Carlos - SP-Brazil. One UASB reactor acted as a control, and the other as a UAHB reactor. In the preliminary essays, the reactors were operated with 6h of hydraulic detention time (HDT) for 200 days. After inoculation, the reactors attained the apparent dynamic equilibrium state after 80 days of operation, with alkalinity generation, low volatile acids concentration and mean organic matter removal of 84% and 85% in terms of COD, and 87% and 91% in terms of BOD, for UASB and UAHB reactors, respectively. After this period, the reactors were submitted to an increasing in up velocity (Vup) of 0.78 m.h-1; 1.17 m.h-1; 1.56 m.h-1 and 1.96 m.h-1. The UAHB reactor showed lesser susceptibility for Vup increase than the UASB reactor. Hydrodynamic tests were also done on the reactors, in addition to routine operational analysis. The structure of the microbial community was evaluated by optical and epifluorescence microscopy, and the DGGE technique. After this step, the UAHB and the UAHBmod reactors were operated out 6h of HDT and Vup of 0.78 m.h-1. The reactors attained the apparent dynamic equilibrium state with alkalinity generation, low volatile acids concentration and mean organic matter removal of 71% and 76% in terms of COD, and 72% and 87% in terms of BOD for the UASB and UAHBmod reactors, respectively. After this period, the UAHBmod reactor was subjected to a Vup of 1.56 m.h-1 and achieved removal efficiencies of 74% COD and 87% BOD.
127

Ocorrência e remoção dos protozoários patogênicos Giardia spp. e Cryptosporidium spp. em sistemas de tratamento de esgoto sanitário / Occurrence and removal of patogenic protozoa Giardia spp. and Cryptosporidium spp. in sanitary sewage treatment systems

Priscila Ribeiro dos Santos 03 July 2015 (has links)
O propósito do presente estudo foi investigar e monitorar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. por diferentes processos de uma estação de tratamento de esgoto (ETE) em escala plena, composta basicamente por tratamento preliminar, reator UASB e flotador por ar dissolvido, e verificar a ocorrência desses protozoários no lodo do reator UASB e do flotador. Além disso, avaliou-se a remoção desses parasitos pelo processo de flotação por ar dissolvido em escala de bancada (equipamento Flotateste). Analisou-se a qualidade das amostras a partir de variáveis físicas e químicas, e pela detecção de microrganismos indicadores - E. coli, coliformes totais e Clostridium perfringens. Os métodos de detecção de protozoários se basearam nas etapas de concentração (tripla centrifugação ou filtração em membrana seguida de tripla centrifugação); purificação por separação imunomagnética (IMS); detecção por reação de imunofluorescência direta (RID). As recuperações de cistos variaram de 32,6 a 67,0 &#37; dependendo do método adotado, já para os oocistos as recuperações estiveram na faixa de 5,6 a 12,0 &#37;. Na ETE-Monjolinho foram detectadas significativas quantidades de cistos de Giardia spp. em 100% das amostras de esgoto analisadas, com concentração média de 1,89 x 104 e 2,35 x 102 cistos.L-1 no esgoto bruto e tratado, respectivamente. Já os oocistos de Cryptosporidium spp. foram detectados em 39,0 &#37; das amostras de esgoto, com concentração média de 1,35 x 102 oocistos.L-1 no esgoto bruto e 5,87 oocistos.L-1 em esgoto tratado (após flotador). A remoção global da ETE para remoção de Giardia spp. foi em média 2,03 log. O lodo do reator UASB e lodo do flotador apresentaram altas quantidade de (oo)cistos, constatando-se a tendência desses sistemas em concentrar os (oo)cistos por seus processos físicos. Algumas correlações significativas foram encontradas, como correlação entre a concentração de cistos no lodo e a variável sólidos totais, a concentração de cistos no esgoto bruto e as variáveis cor aparente, DQO total e particulada, e a concentração de cistos no efluente UASB e o microrganismo Clostridium perfringens. Diferentemente do flotador em escala plena, o processo do flotação por ar dissolvido em escala de bancada alcançou elevadas remoções médias de cistos de Giardia spp., entre 2,5 e 2,7 log nas diferentes condições de floculação estudadas. / The aim of this study was to investigate and monitor the removal of Giardia spp. cysts and Cryptosporidium spp. oocysts through different processes of a sewage treatment plant (STP) in full scale, consisted of preliminary treatment, UASB reactor, dissolved air flotator, and to verify the occurrence of the protozoa in the sludge derived from UASB reactor and flotator. Besides that, it was evaluated the removal of these parasites through the dissolved air flotation process in bench scale. It was analyzed the quality of the samples through physical and chemical variables, and detection of indicator microorganisms &#8211; E. coli, total coliforms and Clostridium perfringens. The detection methods of protozoa were based on steps of concentration (triple concentration or membrane filtration followed by triple concentration); purification by immunomagnetic separation (IMS); immunofluorescence assay (IFA). The recovery of cysts ranged from 32,6 to 67,0 &#37; according to the adopted method, while the recovery for the oocysts ranged from 5,6 to 12,0 &#37;. It was detected significant quantities of Giardia spp. cysts in 100 &#37; of the analyzed sewage samples at the STP-Monjolinho, with mean concentration of 1,89 x 104 e 2,35 x 102 cysts.L-1in raw sewage and treated sewage, respectively. The oocysts of Cryptosporidium spp. were detected in 39,0 &#37; of the sewage samples, with mean concentration of 1,35 x 102 oocysts.L-1 in raw sewage and 5,87 oocysts.L-1 in treated sewage (after flotator). The overall removal for Giardia spp. was on average of 2,03 log. The sludge from UASB reactor and flotator presented high quantities of (oo)cysts, implying the tendency of these systems to concentrate (oo)cysts through its physical processes. Some correlations were obtained, such as correlation between the concentration of cysts in the sludge and total solids, the concentration of cysts in the raw sewage and apparent color, total and particulate COD (chemical oxygen demand), and the concentration of cysts in the UASB effluent and the microorganism Clostridium perfringens. Unlike the full flotator, the dissolved air flotation in bench scale reached significant mean removal of Giardia spp. cysts, between 2,5 and 2,7 log according to the different flocculation conditions.
128

Tratamento de águas residuárias simuladas de indústrias de pasta celulósica não branqueada e branqueada / Bleached and unbleached cellulose pulp plant synthetic wastewater treatment

Andréa Paula Buzzini 01 September 2000 (has links)
Este estudo teve como objetivo avaliar o desempenho de 2 reatores anaeróbios de fluxo ascendente e manta de lodo (UASB), em escala de bancada, tratando licor negro diluído, durante 635 dias de operação contínua. Durante a Fase I os reatores foram alimentados com licor negro diluído, enriquecido com nutrientes essenciais, simulando os efluentes de uma indústria de pasta celulósica não branqueada. Durante a Fase II, um dos reatores foi alimentado com o mesmo substrato mais uma mistura de cinco compostos organoclorados, simulando os efluentes de uma indústria de pasta celulósica branqueada. O aumento da taxa de carregamento orgânico, na Fase I, de 0,40 kg DQO/dia m3 para 0,70 kg DQO/dia m3 não provocou diminuição da eficiência de remoção de DQO. Por outro lado, o aumento da taxa de carregamento hidráulico de 0,50 m3/dia m3 para 1,00 m3/dia m3 provocou diminuição de aproximadamente 10% na eficiência média de remoção de DQO no reator 1 e em torno de 12% no reator 2. A adição de 15,00 mg/L dos compostos organoclorados, não influenciou significativamente o desempenho do reator. A eficiência média de remoção de DQO na Fase II foi de 82% no reator de controle e de 79% no reator de tratamento. As eficiências médias de remoção dos compostos organoclorados foram de: 99,9% para o 2-clorofenol, 97,5% para o 2,4- diclorofenol, 95,8% para o 2,6-diclorofenol, 98,9% para o 2,4,6-triclorofenol e 92,8% para o tetraclorocatecol. / This research was conducted to assess the performance of two bench scale upflow anaerobic sludge blanket (UASB) reactors used for the treatment of diluted black liquor, over 635 days of continuous operation. During Phase I of the study both reactors were fed with the diluted black liquor enriched with essential nutrients. This substrate simulated the wastewater from unbleached cellulose pulp plant. Progressing in the research, during Phase II, one of the reactors was fed with the same substrate plus a mixture of five chlorinated organic compounds to simulate the wastewater from a bleached pulp plant. The increase in the organic loading rate, during Phase I, from 0.40 kg COD/m3.day to 0.70 kg COD/m3.day did not result in a decrease in the COD removal efficiency. On the other hand, the increase in the hydraulic loading rate from 0.50 m3/day.m3 to 1.00 m3/day.m3 resulted in a decrease of approximately 12 percent points in the average COD removal efficiency in the reactor 1 and approximately 12 percent points in the reactor 2. The addition of 15 mg/L of chlorinated organic compounds did not have a significant influence in the reactor performance in this research. The removal efficiency of COD during the second phase reached 82% in the control reactor and 79% in the treatment reactor. The average removal efficiencies for the chlorinated organic compounds were: 99.9% for 2-chlorophenol; 97.5% for the 2,4-dichlorophenol; 95.8% for the 2,6- dichlorophenol; 98.9% for the 2,4,6-trichlorophenol and 92.9% for the tetrachlorocatechol.
129

Resposta dinâmica dos reatores UASB (Upflow Anaerobic Sludge Blanket) submetidos a cargas senoidais / not available

Kátia Bakker Batista 16 November 2000 (has links)
Esta pesquisa consistiu na verificação do comportamento do reator UASB de bancada (volume igual a 10,5 litros), quando submetido a variações senoidais de vazão afluente, comparando-se com a eficiência no seu funcionamento com vazão constante, através de análises de amostras de afluentes e efluentes. O reator UASB utilizado foi montado no Laboratório de Processos Biológicos da EESC-USP dentro de uma câmara com temperatura constante de 30 ± 3°C, e alimentado com esgoto sintético, com DQO de 500 mg/l, 750 mg/l e 1000 mg/l. O reator foi inoculado em abril de 1999, com 3,5 litros de lodo anaeróbio proveniente de um reator compartimentado, também situado na EESC-USP. Devido à dificuldade de atingir um valor esperado para a eficiência de remoção de Matéria orgânica, foi dada nova partida no reator, em julho de 1999, desta vez com lodo proveniente de outro UASB. Após a segunda partida, o reator operou com vazão constante e DQO afluente em torno de 500 mg/l até setembro de 1999, com média de remoção de DQO bruta de 75% no período, passando-se, então, à fase de variação senoidal de vazão de forma que o máximo e o mínimo fossem de ±30%, ±45% e ±60% da vazão média. Para este regime, obteve-se 80% de eficiência média de remoção de DQO bruta. Os valores de pH, alcalinidade e ácidos voláteis foram praticamente constantes durante a operação. Os perfis de remoção de DQO ao longo do dia mostraram uma pequena queda na eficiência do reator, aproximadamente 1,5 vezes o tempo de detenção hidráulica médio (8 horas), após os máximos de vazão para o regime de variação de vazão de ±30% e ±45% e 2,5 vezes o tempo de detenção hidráulica médio, para variação e ±60%. O mesmo experimento foi repetido para DQO afluente de 1000 mg/l e obteve-se, em média, eficiências de 65% de remoção de DQO. / This research consisted in the UASB reactor performance verification when it was submitted to sine-based variations of loading rate, in comparison to its normal operation. The UASB reactor used was set up at the Biological Process Laboratory of EESC-USP, inside a camera with temperature of 30°C ± 3°C. It was fed with synthetic sewage (COD = 500, 750 and 1000 mg/l). After start-up, the reactor was operated with constant loading rate (COD = 500 mg/l) until September 1999. The organic matter removal average in this period was 75%. Then, it was initiated the phase of sine-based variation loading rate (±30%, ±45% and ±60%). In this regime, it was obtained a medium gross COD removal efficiency of 80%. The pH values, alkalinity and volatile acids were practically constant during the operation. The COD removal profiles during the day showed a subtle fall in the reactor efficiency after 1.5 times the medium hydraulic detection time, for the loading rate variation of ±30% and ±45%. For ±60% variation, the answer time was approximately 2.5 times the medium hydraulic detection time. The efficiency of gross COD removal stay however over 78,53% until the experiment 9, witch showed that the reactor can stand the loading rate variations. The efficiency of filtered COD removal decreased on the second experiment, came back to the initial values and decreased again. The values of variation didn\'t surpass 6,6% for gross COD and 8,43% for filtered COD.
130

Remoção de cistos de Giardia spp. e de Cryptosporidium spp. em sistema de tratamento de esgoto sanitário: quantificação em fases líquida e sólida / Removal of Giardia spp. cysts and Cryptosporidium spp. oocists in wastewater treatment systems: quantification in liquid and solid fases

Eraldo Kobayashi dos Santos 25 September 2015 (has links)
No atual cenário de saneamento, há uma escassez de estudos na temática de retenção de microrganismos patogênicos em estações de tratamento de esgotos, onde os principais tratamentos se baseiam na remoção de parâmetros físico-químicos. Uma abordagem mais ampla na remoção destes microrganismos em estações de tratamento e sua quantificação no lodo retido é um passo importante para o aumento do debate acerca da eficiência dos atuais tratamentos utilizados na retenção de patógenos, diminuindo assim a contaminação de corpos d\'água com posteriores problemáticas no âmbito de saúde pública. Desta forma, a proposta do projeto foi avaliar e quantificar a remoção de cistos de Giardia spp., oocistos de Cryptosporidium spp. e Escherichia Coli em sistema de tratamento de esgoto sanitário constituído de tratamento anaeróbio (reator UASB), utilizando dois valores de TDH - 8 horas (Etapa 1) e 12 horas (Etapa 2) - seguido de tratamento em sistema de lodo ativado. O projeto utilizou uma estação de tratamento piloto junto a estação de tratamento da USP São Carlos. Para análises de E. coli e coliformes totais foi utilizada a técnica de pour plate e para detecção de cistos e oocistos de Giardia spp. e Cryptosporidium spp., a técnica de separação imunomagnética (IMS) e técnica de Reação de Imunoflorescência Direta (RID) foi escolhida como método de detecção e quantificação. Para a remoção no reator UASB, a variação de TDH indicou influência na remoção de parâmetros físico-químicos e na retenção de microrganismos, sendo que a utilização de TDH de 12 horas obteve remoções de 0,21 log para cistos Giardia spp. e 0,48 log para oocistos de Cryptosporidium spp. Para o Sistema de Lodo ativado, as remoções foram de 0,48 log e 0,15 para ambos os microrganismos, respectivamente, não havendo influência significativa na retenção com a mudança de TDH do reator UASB. Nas análises em fase sólida, foram observados valores altos de contaminação no lodo, tanto para Giardia spp., quanto para Cryptosporidium spp., onde a viabilidade dos (oo)cistos detectados estiveram na faixa de 30% a 99% nas amostras analisadas. / Currently, the field of sanitation faces a lack of studies on retention of pathogenic microorganisms in wastewater treatment plants, where main treatments are based on the removal of physical and chemical parameters. A broader approach to the removal of pathogens in wastewater treatment systems and their quantification in retained sludge is an important step to increase the debate around the efficiency of prevailing treatments used to retain those microorganisms and to consequently reduce the contamination of water bodies. The present study was conducted to assess and quantify the removal of Giardia spp. cysts, Cryptosporidium spp. oocysts and E. coli in wastewater treatment systems. For the purpose of this research, the treatment consisted of a UASB reactor using two values of hydraulic retention time (HRT) - 8 hours (phase 1) and 12 hours (phase 2) - followed by an activated sludge system. The project was staged in a pilot wastewater treatment plant coupled to USP Sao Carlos\' wastewater treatment system. Pour plate technique was used for analysis of E.coli and total coliforms. IMS was used to detect cysts and oocysts of Giardia spp. and Cryptosporidium spp. DFA (direct immunofluorescence assay) method was chosen to detection and quantification. HRT variation for removal in UASB reactor indicated influence in removal of physical and chemical parameters and in retention of microorganisms. The 12 hours use of HRT obtained removals of 0.21 log for Giardia cysts and 0.48 log for Cryptosporidium oocysts. Activated sludge removals presented 0.48 log and 0.15 log respectively, without significative influence in retention with the HRT\'s change in UASB reactor. High values of contamination were observed during solid-phase analysis in activated sludge, both for Giardia and Cryptosporidium. Here, viability of the (oo)cysts detected was around 30% up to 99% of the analyzed samples.