• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 566
  • 154
  • 15
  • 14
  • 10
  • 10
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 830
  • 385
  • 223
  • 103
  • 98
  • 95
  • 75
  • 74
  • 70
  • 69
  • 69
  • 67
  • 64
  • 63
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Padronização e comparação dos valores ecobiométricos e eletrorretinográficos em cães hígidos das raças Terrier Brasileiro e Beagle

Guimarães, Patrícia Jordão [UNESP] 28 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-28Bitstream added on 2014-06-13T18:51:08Z : No. of bitstreams: 1 guimaraes_pj_me_jabo.pdf: 341115 bytes, checksum: 109770fb0b798c5964a07df11b13e7d8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Com a pesquisa, objetivou-se padronizar e comparar valores ecobiométricos e eletrorretinográficos em cães das raças terrier brasileiro e beagle. Utilizaram-se vinte cães, sendo dez da raça terrier brasileiro e dez da beagle, machos e fêmeas hígidos. A ecobiometria foi realizada por ultrassonografia em modos A e B sob contenção física. Avaliaram-se o diâmetro axial do olho, a espessura da lente e os comprimentos das câmaras anterior e vítrea. A eletrorretinografia foi realizada de acordo com o protocolo Dog Diagnostic Protocol sob anestesia com propofol. Os dados foram analizados em software HMsERG, onde mensuraram-se as amplitudes e os seus respectivos tempos implícitos. Em ambas as raças estudadas, não se observaram diferenças significativas entre os olhos direito e esquerdo, quanto aos valores mensurados à ecobiometria ocular (p>0,05). Todavia, os valores relativos ao comprimento axial (p=0,023) e a câmara anterior (p=0,01) de cães da raça beagle foram significativamente maiores que os da raça terrier brasileiro. Nos períodos de resposta de adaptação dos bastonetes, não houve diferença estatística entre as raças (p>0,05). Relativamente à resposta mista, embora sem diferença estatística, observou-se que as amplitudes das ondas A (p=0,24) e B (p=0,23) na raça terrier brasileiro, foram respectivamente, 51,78% e 17,30% maiores que na raça beagle. Não houve significância para valores de onda B nas fases fotópticas, entretanto, o tempo implícito na raça beagle foi significativamente maior (p=0,03) na fase clara com luz estroboscópica. Conclui-se que a câmara anterior e o diâmetro axial do bulbo dos olhos de beagles apresentam comprimentos significativamente maiores que os de terrier braileiros. Embora os parâmetros eletrorretinográficos não tenham diferido significativamente entre as... / The aim of the present study were to standardize and compare echobiometric and eletrorretinographic values in the brazilian terrier and beagle breeds. Twenty healthy dogs, being ten brazilians terrier and ten beagles, of both gender, were employed in this study. The echobiometry was accomplished by means of A and B mode ultrassonography under physical restrain. Axial globe length, lens thickness, anterior and vitreous chamber depth were evaluated. Electroretinography was performed using the Dog Diagnostic Protocol under anesthesia with propofol. Eletroretinographic recordings were evaluated with specific software, where the A and B wave amplitudes and their implicit times were measured. Echobiometric values did not change significantly between right and left eyes in both breeds (P>0.05). During rod response data did not change significantly between breeds (P>0.05). On mixed response, statistical difference was not observed, however, A (P=0.24) and B (P=0.23) wave amplitudes were, respectively, 51.78% and 17.30% higher in brazilian terrier breed. During the photoptic period, B wave amplitudes did not change significantly, however the implicit time seen with stroboscopic light was significantly higher (P=0.03) in beagles. It is concluded that anterior chamber depth and axial globe length were significantly higher in beagles than in brasilian terriers. Though, eletroretinographic values did not change significantly between breeds, higher amplitudes and shorter implicit time were seen in brazilian terriers, suggesting that such findings may be related to its smaller eyes
142

Avaliação estrutural da próstata de cães: comparação entre punção aspirativa com agulha fina guiada por ultra-som e biópsia por videolaparoscopia

Paula, Thaís Melo de [UNESP] 25 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-25Bitstream added on 2014-06-13T20:30:36Z : No. of bitstreams: 1 paula_tm_me_jabo.pdf: 308035 bytes, checksum: d1c2ccf37b7850b81976527f8cf43033 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A próstata é o único órgão sexual acessório no cão e as afecções prostáticas são comuns em cães adultos a idosos. A história clínica, anamnese, sinais clínicos e exames complementares, como a radiografia, ultra-sonografia, citologia e a histopatologia auxiliam no diagnóstico, embora o diagnóstico definitivo se fundamenta no exame histopatológico da próstata. Neste estudo, 11 animais da espécie canina, machos, adultos, não castrados e hígidos foram submetidos à punção aspirativa com agulha fina guiada por ultra-som para avaliação citológica e, após, um mínimo sete dias, utilizou-se da videolaparoscopia para obtenção de fragmento prostático para avaliação histopatológica. Nos exames citológicos, dois animais apresentaram alterações celulares compatíveis com hiperplasia prostática benigna. Durante as videolaparoscopias, a colheita do fragmento prostático foi realizada de maneira rápida, não sendo observada hemorragia significativa após o procedimento. Os animais não apresentaram nenhuma complicação no período pós-operatório. Verificou-se, aos exames histopatológicos, morfologia e estrutura celulares e teciduais nos padrões normais do parênquima prostático, em nove animais; os dois restantes apresentaram alterações celulares e teciduais sugestivas de hiperplasia prostática benigna. / The prostate is the only sexual accessory gland in the male dog. The prostate diseases are common in adult and geriatric dogs. The clinical history, anamnesis, clinical signs and complementary exams, as radiography, ultrasonography, cytology and histopathology are helpful for the diagnosis, despite the definitive diagnosis is based on prostate histopathologic exams. In this study, 11 healthy intact male dogs were submitted to ultrasound fine needle aspirative puncture for cytologic exam and after, at least 7 days later, by videolaparoscopic fragment collection for further histopathologic evaluation. On cytologic exams, two animals presented changes which correlates with benign prostatic hyperplasia. During the videolaparoscopic proceedings, the prostate fragment collections were made in a quick way and no important hemorrhagic lost has been seen after the collection. The animals presented no complication after the surgeries. The histopathologic exams showed normal prostate parenchyma based on the cellular and tissue morphology and structure in 9 dogs, and the others 2 presented cellular and tissue changes suggesting benign prostatic hyperplasia.
143

Obtenção de pós nanométricos de hidroxiapatita sintetizados com magnésio utilizando ultra-som / Obtention of hydroxyapatite nanometric powders synthesized with magnesium using ultrasound

GOUVEIA, DEIBY S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:22Z (GMT). No. of bitstreams: 1 12759.pdf: 23849900 bytes, checksum: e0631f64bab4ba1dda3b9a8d5760ae19 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
144

Doppervelocimetria da artéria oftálmica nas formas precoce e tardia da pré-eclâmpsia / The ophthalmic astery doppervelocimetry in the early and late forms of preeclampsia

Silva Netto, José Paulo da [UNESP] 25 February 2015 (has links) (PDF)
Made available in DSpace on 2016-08-12T18:48:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-25. Added 1 bitstream(s) on 2016-08-12T18:50:54Z : No. of bitstreams: 1 000865086.pdf: 934928 bytes, checksum: eb6038cce39a9a5888e0b2a6ce4c0de4 (MD5) / Introdução: A pré-eclâmpsia contribui consideravelmente para o aumento da morbimortalidade materna e perinatal. Pode ser classificada em precoce e tardia, de acordo com a época de seu aparecimento. O Doppler da artéria oftálmica é um método objetivo que pode facilitar o diagnóstico da hipertensão durante a gestação, identificando suas diferentes formas de manifestação. Objetivo: Diferenciar, por meio do Doppler da artéria oftálmica, o padrão hemodinâmico da artéria oftálmica das gestantes portadoras de pré-eclâmpsia precoce daquelas portadoras de pré-eclâmpsia tardia. Metodologia: Estudo transversal de 67 gestantes com pré-eclâmpsia precoce e 93 gestantes com pré-eclâmpsia tardia realizado no terceiro trimestre de gestação. Todas as gestantes realizaram Doppler da artéria oftálmica direita, que avaliou os seguintes parâmetros, para quantificação da onda de velocidade de fluxo: índice de resistência (IR), índice de pulsatilidade (IP), pico de velocidade sistólica (PVS), pico de velocidade diastólica (PVD), velocidade diastólica final (VDF) e razão entre picos de velocidade (RPV). Os resultados foram submetidos à análise estatística, considerando-se significativos quando p<0,05. Resultados: As médias dos índices dopplervelocimétricos das gestantes com pré-eclâmpsia precoce e pré-eclâmpsia tardia foram respectivamente: IR= 0,7 ± 0,1; 0,7 ± 0,1, IP= 1,3 ± 0,4; 1,4 ± 1,1, PVS: 33,2 ± 8,2; 34,3 ± 10,0, PVD: 26,5 ± 8,1; 25,5 ± 9,4, VDF: 11,2 ± 3,8; 11,7 ± 4,6 e RPV: 0,8 ± 0,2; 0,7 ± 0,2. A razão de pico de velocidade foi significativamente maior nas gestantes com pré-eclâmpsia precoce. Não houve diferença significativa em relação aos valores de índice de resistência, índice de pulsatilidade, pico de velocidade sistólica, pico de velocidade diastólica e velocidade diastólica final. Conclusão: O Doppler da artéria oftálmica é um exame que pode ser usado na avaliação de... / Introduction: Preeclampsia contributes considerably to increased maternal and perinatal morbidity and mortality. This disease can be classified into early and late onset preeclampsia, according to the timing of their clinical manifestations appearance. The ophthalmic artery Doppler is an objective method that can facilitate the diagnosis of hypertension during pregnancy, identifying its different manifestations. Objective: Differentiate through the Doppler of the ophthalmic artery the hemodynamic pattern of the ophthalmic artery of early and late onset preeclampsia. Methods: Cross-sectional study of 67 pregnant women with early preeclampsia and 93 pregnant women with late preeclampsia performed in the third trimester of pregnancy. All women had performed the right ophthalmic artery Doppler that evaluated the following parameters for the quantification wave flow rate: resistance index (RI), pulsatility index (PI), peak systolic velocity (PSV), peak diastolic velocity (PVD), end-diastolic velocity (EDV) and peak velocity ratio (RPV). The results were subjected to statistical analysis, considering significant when p <0.05. Results: The mean Doppler indices of early and late onset preeclampsia were: RI = 0.7 ± 0.1 vs 0.7 ± 0.1, IP= 1.3 ± 0.4 vs 1.4 ± 1.1, PVS: 33.2 ± 8.2 vs 34.3 ± 10.0, PVD: 26.5 ± 8.1 vs 25.5 ± 9.4, VDF: 11.2 ± 3.8 vs 11.7 ± 4.6 and RPV: 0.8 ± 0.2 vs 0.7 ± 0.2. The speed of peak ratio was significantly higher in patients with early preeclampsia. There was no significant difference in terms of resistance index values, pulsatility index, peak systolic velocity, peak diastolic velocity and end diastolic velocity. Conclusion: The Doppler of the ophthalmic artery is a test that can be used in the evaluation of pregnant women with preeclampsia, showing difference in quantitative indices such as peak velocity ratio when comparing women with early and late onset preeclampsia
145

Ultrassonografia modo B de alta resolução modo Doppler e uso de contraste de microbolhas na avaliação testicular de gatos domésticos /

Brito, Marina Botelho Soares de. January 2015 (has links)
Orientador: Marcus Antonio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Banca: Pedro Paulo Maia Teixeira / Banca: Anelise Carvalho Nepomuceno / Resumo: As pesquisas envolvendo a reprodução de gatos domésticos comumente baseiam-se em análise macroscópica e andrológica do sistema reprodutor desses animais, não havendo nenhum estudo até o momento sobre a avaliação ultrassonográfica dos testículos nesta espécie. Sendo assim, este estudo prospectivo visou realizar a varredura ultrassonográfica dos testículos de 45 gatos adultos domésticos, utilizando as técnicas Modo B, Doppler e Ultrassonografia por Contraste com Microbolhas. Os resultados obtidos ao exame ultrassonográfico modo B demonstraram as estruturas testiculares com ecotextura homogênea e com ecogenicidade dentro da normalidade (semelhante à ecogenicidade do tecido esplênico), com presença de linha mediastinal evidente. Ao Doppler colorido testicular, foi possível verificar artéria testicular com padrão de ondas arterial e monofásico, em região de cordão espermático. Utilizando o Doppler Espectral, obtiveram-se os índices vasculares dos testículos direito e esquerdo, respectivamente: VS = 6.23 cm/s, VD = 2.77 cm/s e IR = 0.53; VS = 6.73 cm/s, VD = 2.8 cm/s e IR = 0.54. A avaliação ultrassonográfica contrastada por microbolhas não resultou em efeitos colaterais aos animais, apresentando-se de aplicação confiável e gerando imagens de qualidade. O contraste preencheu as estruturas vasculares subcapsulares, com moderado realce homogêneo do parênquima, além de rápida redução da ecogenicidade após o pico de realce. Os valores de tempo para o contraste de microbolhas, considerando tempo de entrada, pico de realce e tempo de saída para os testículos direito e esquerdo foram, respectivamente: tempo de entrada = 10.76 s, pico de realce = 21.50 s e pico de saída = 81.81; tempo de entrada = 8.78 s, pico de realce = 21.62 s e tempo de saída = 75.36. Esses exames foram facilmente aplicados em gatos domésticos e devem ser utilizados como técnicas auxiliares no diagnóstico de anormalidades testiculares... / Abstract: Research involving breeding of domestic cats are commonly based on macroscopic and andrologic analysis, there is no study to date with sonographic evaluation of domestic cats testicle. Thus, this study aimed to perform the ultrasound scan of 45 adult domestic cats testicles, using the techniques of B mode, Triplex Doppler ultrasound and contrast-enhanced. The results showed homogeneous testicles, with normal echogenicity and echotexture, with evident mediastinal line. Testicular artery was observed in the spermatic cord with tortuous patter and showed monophasic-patterned waves and low vascular resistance and with systolic peak evident. Values of indices vascular were as follows: SV = 6.73 cm/s, DV = 2.8 cm/s and RI = 0.54 for left testicles; and SV = 6.23 cm/s, DV = 2.77 cm/s and RI = 0.53 for right testicles. The contrast-enhanced resulted in no side effects, being reliable and generating quality images. Contrast filled the subcapsular vascular structures and after a few seconds, a homogeneous moderate enhancement of the parenchyma, with parenchymal vessels still distinguishable and after the peak phase, a rapid homogeneous decrease in echogenicity. Values of time for contrast-enhanced ultrasonography were as follows: wash-in = 8.78 s, peak enhancement = 21.62 s and wash-out = 75.36 for left testicles; and wash-in = 10.76 s, peak enhancement = 21.50 s and washout = 81.81 for right testicles. The examination in Doppler mode showed testicular artery with monophasic-patterned waves in spermatic cord. These tests were easily applied in domestic cats and should be used as auxiliary techniques in the diagnosis of testicular abnormalities in this species / Mestre
146

Ultrassonografia transcraniana em cães adultos hígidos : padronização da técnica, aspectos anatômicos e biométricos /

Cintra, Thassila Caccia Feragi. January 2011 (has links)
Resumo: Com este trabalho objetivou-se correlacionar a ultrassonografia transcraniana com a anatomia encefálica, confeccionar um atlas com cortes anatômicos do encéfalo, à similitude dos planos de varredura ultrassonográficos, identificando e mensurando nas imagens as estruturas encefálicas visibilizadas, para padronizar dimensões em cães mesaticéfalos. Foram utilizados 37 cães adultos, hígidos, sem raça definida, sendo 30 in vivo e sete cadáveres. Nos cadáveres, após varredura, as cabeças foram removidas e seccionadas em planos anatômicos à similitude dos planos ultrassonográficos. Nos animais in vivo a identificação e as mensurações das estruturas encefálicas foram comparadas entre si para avaliar a repetibilidade da varredura eletrônica. No encefálo foram realizados cortes ultrassonográficos em planos dorsais e dorsais oblíquos pela janelas temporal e occipital, sendo passível visibilizar regiões dos lobos frontal, temporal e occipital, ventrículos laterais, septo pelúcido, fissura longitudinal do cérebro, sulcos suprasilviano, marginal e coronal, cerebelo, tentório ósseo do cerebelo, vermes do cerebelo, e medula oblonga. As médias e os desvios padrão das estruturas encefálicas nos 30 cães in vivo não variaram (p>0,05) em função das janelas temporais e foram 0,277cm ± 0,030 e 0,281cm ± 0,024; 1,643cm ± 0,115; 0,161 ± 0,021 e 0,157 ± 0,016; 2,248 ± 0,166 e 2,368 ± 0,212, respectivamente para largura dos ventrículos laterais direito e esquerdo; manto encefálico; espessura dos sulcos marginal e coronal; diâmetros ventro-lateral e crânio-caudal da região cerebelar / Abstract: The goals o this study were to correlate transcranial ultrasonography with brain anatomy, to make an atlas with anatomical cuts of the brain that were similar to the ultrasound plane images, to identify and to measure the brain structures visualized, in order to standardize their dimensions in mesaticephalic dogs. In this experiment, 37 adult, healthy mongrel dogs were used - 30 alive and 7 corpses. After the ultrasound procedure the head of the corpse was removed and cut in anatomical planes as the ultrasound plane images. In the live animals, the brain structures identification and measurements were compared to each other to assess the reprodutibility of the ultrasound procedure. Ultrasound scans in dorsal and dorsal oblique planes were performed in the brain through the temporal and occipital window, with visualization of the frontal, temporal and occipital lobe, lateral ventricles, septum pellucidum, the longitudinal fissure of the brain, suprasylvian, marginal and coronal sulcus, cerebellum, the osseous tentorium of the cerebellum, the vermis of the cerebellum and the medulla oblongata. The average and the standard deviation of the brain structures of the 30 live dogs did not vary (p>0,05) in both temporal window and were 0,277cm ± 0,030 e 0,281cm ± 0,024; 1,643cm ± 0,115; 0,161 ± 0,021 e 0,157 ± 0,016; 2,248 ± 0,166 e 2,368 ± 0,212, respectively for width of the right and left lateral ventricles and cerebral mantle, thickness of the marginal and coronal sulcus, and ventrolateral and canio-caudal cerebellar diameter / Orientador: Júlio Carlos Canola / Coorientador: Cibele Figueira Carvalho / Banca: Márcia Rita Fernandes Machado / Banca: Tilde Rodrigues Froes / Mestre
147

Ultrassonografia do bulbo do olho de cães, com diferentes conformações cranianas /

Toni, Maria Carolina. January 2011 (has links)
Orientador: Júlio Carlos Canola / Banca: José Luiz Laus / Banca: Fabrício Singaretti de Oliveira / Resumo: Com o presente estudo pretendeu-se conhecer os valores médios para as estruturas intraoculares e compará-los entre cães com diferentes conformações cranianas por meio da ultrassonografia ocular com transdutor de 20 MHz. Foram selecionados 30 cães, adultos, peso corpóreo até 10 kg, machos ou fêmeas, hígidos, atendidos no Hospital Veterinário "Governador Laudo Natel" - Faculdade de Ciências Agrárias e Veterinárias - UNESP - Câmpus de Jaboticabal. Os cães foram distribuidos em três grupos: G1 - 10 braquicefálicos, G2 - 10 mesocefálicos e G3 - 10 dolicocefálicos. Na análise estatística realizada pelo teste t Student com nível de significância de 5%, não houve diferença entre os olhos direito e esquerdo dos cães do mesmo grupo (p > 0,05). Valores médios e desvios padrão foram obtidos para profundidade da câmara anterior (D1), espessura da lente (D2), profundidade da câmara vítrea (D3) e comprimento axial do bulbo do olho (D4) nos três grupos. G1: D1 2,92mm (± 0,37), D2 7,03mm (± 0,61), D3 9,48mm (± 0,74) e D4 19,43mm (± 0,60). G2: D1 3,08mm (± 0,67), D2 7,02mm (± 0,87), D3 8,76mm (± 1,23) e D4 18,86mm (± 1,45). G3: D1 3,07mm (± 0,65), D2 7mm (± 0,81), D3 9,75mm (± 0,98) e D4 19,82mm (± 0,95). Para comparação dos valores médios de D1, D2, D3 e D4 entre os grupos, foi utilizado o teste de Tukey, com nível de significância de 5%. Na análise de D3, foi observada diferença (p < 0,05) na comparação entre G2 e G3. Na análise de D4, foi observada diferença (p < 0,05) na comparação entre G2 e G3 / Abstract: The present study aimed to know the average values of the intraocular structures and compare among different skulls' conformations in dogs using ocular ultrasonography with 20 MHz probe. They were selected 30 healthy adult dogs, body weight 10 kg, male or female, assisted at "Governador Laudo Natel" Veterinary Teaching Hospital - Faculdade de Ciências Agrárias e Veterinárias - UNESP - Campus of Jaboticabal. Animals were divided into three groups: G1 - 10 brachycephalic dogs, G2 - 10 mesocephalic dogs and G3 - 10 dolicocephalic dogs. The Student t test at 5% significance level was used to compare difference between right and left eyes of the dogs in the same group and no difference was found (p > 0.05). Mean and standard deviations were obtained for anterior chamber depth (D1), lens thickness (D2), vitreous chamber depth (D3) and axial length of the eye globe (D4) in the three groups. G1: D1 2.92mm (± 0.37), D2 7.03mm (± 0.61), D3 9.48mm (± 0.74) and D4 19.43mm (± 0.60). G2: D1 3.08mm (± 0.67), D2 7.02mm (± 0.87), D3 8.76mm (± 1.23) and D4 18.86mm (± 1.45). G3: D1 3.07mm (± 0.65), D2 7mm (± 0.81), D3 9.75mm (± 0.98) and D4 19.82mm (± 0.95). The Tukey test at 5% significance level was used to compare the average of D1, D2, D3 and D4 among groups. Differences between G2 and G3 were found (p <0.05) when comparing D3 and D4 / Mestre
148

Avaliação do uso da ultrassonografia modo B para exploração através de tecido ósseo de costelas bovinas / Evaluation of the use of ultrasound B-mode exploration through bone beef ribs

Marcos Petto Nunes de Abreu 30 July 2012 (has links)
O uso da ultrassonografia, para diagnóstico, como forma de exame complementar na área da Saúde é cotidiano e consagrado, principalmente no estudo e avaliação das doenças em tecidos moles. Com a consolidação e o desenvolvimento deste método, novos usos vem sendo descritos. Existem relatos científicos da possibilidade do uso do ultrassom para avaliação de lesões no interior do tecido ósseo. Frente a esta alternativa, o presente estudo avaliou o uso da ultrassonografia para exploração através de tecido ósseo, de diferentes espessuras, com a utilização de um modelo laboratorial em costelas bovinas, definindo a espessura óssea cortical que permite a passagem do ultrassom. Primeiramente realizamos um ensaio experimental para definir a melhor metodologia para o estudo. O modelo laboratorial usado era constituído por uma costela bovina, macerada, desgastada em diferentes espessuras. A amostra do estudo foi constituída em 180 leituras de ultrassom provenientes de 20 costelas bovinas maceradas; onde cada uma delas foi examinada em 9 áreas que se diferenciavam na espessura do remanescente ósseo; assim definidas 4,0mm, 3,0mm, 2,5mm, 2,0mm, 1,5mm, 1,0mm, 0,5mm, 0,2mm e sem desgaste. Para os exames de ultrassom foi utilizado o aparelho de ultrassom portátil Terason t3000 (Terason, divisão da Teratech Corporation, USA). Os exames foram realizados pela técnica da imersão, onde se mergulhava os espécimes e o transdutor do ultrassom em um recipiente com água. Para avaliar se havia ou não passagem da onda de ultrassom pelo tecido ósseo, em uma determinada espessura, era observada a formação de imagem de um objeto metálico posicionado atrás do osso. Conforme observado pela tabulação dos resultados ocorreu a passagem das ondas de ultrassom através do osso de espessuras 2,0mm, 1,5mm, 1,0mm, 0,5mm e 0,2mm diferentemente do ocorrido nas espessuras 4,0mm, 3,0mm, 2,5mm e sem desgaste. Houve diferença estatisticamente significante (P<0,001) entre as espessuras menores ou iguais a 2,0mm e as espessuras maiores ou iguais a 2,5mm, quanto a formação de imagem ultrassonográfica de um objeto metálico posicionado atrás do tecido ósseo. Concluímos que houve possibilidade de utilização do exame de ultrassom na avaliação através do tecido ósseo de espessuras menores ou iguais a 2,0mm. / The use of ultrasound as a complementary examination in health diagnoses is something usual and well established, mainly in the study and evaluation of diseases in soft tissue. As the consolidation and development of this method ocourred, new uses for it has been described. There are scientific reports with the possibility of the use of ultrasound for the evaluation of lesions within the bone tissue. Faced with this alternative, the aim of the present study was to evaluate the use of ultrasound for exploration through the bone tissue of different thicknesses, using a laboratory model of beef ribs, so thath would be defined the minimum required thicknesses of cortical bone for passage of the ultrasound. First we conducted an experimental trial to determine the best methodology for the study. The laboratory model used consisted of beef ribs prepared in different thicknesses. The study sample consisted of 180 ultrasound readings from 20 macerated beef ribs, each of which was examined in 9 different areas defined as, no wear, 4.0 mm, 3.0 mm, 2.5 mm, 2.0 mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm in thicknesses of the remaining bone. For ultrasound scanning was used a portable ultrasound device, Terason t3000 (Terason, a division of Teratech Corporation, USA). The examinations were performed by the technique of immersion, where the specimens and the ultrasound transductor were immersed in a water tank. To assess whether there was passage of ultrasound waves by the bone tissue in a certain thickness, it was observed the occurrence of a image formation from a metallic object that was positioned behind the bone. As noted by tabulating the results, there was passage of ultrasound waves through the bone thickness 2.0mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm different from those occurred in thickness of 4.0mm, 3.0mm, 2.5mm and no wear. There was significant difference (P<0.001) between the thicknesses less than or equal to 2.0 mm and thickness greater than or equal to 2.5 mm, in the ultrasound imaging of a metallic object positioned behind the bone. We conclude that there was possibility of using the ultrasound examination in the evaluation through the bone thickness less than or equal to 2.0mm.
149

Proposta de mapeamento da vascularização normal da face por meio da ultrassonografia modo B e Doppler / Mapping proposition of the normal vasculature of the face though ultrasound B-mode and Doppler

Maria José Albuquerque Pereira de Sousa e Tucunduva 31 July 2012 (has links)
O estudo do aporte sanguíneo da face é importante em função da cirurgia como para as cirurgias que fazem uso de retalhos. O bom restabelecimento da área depende da perfusão obtida. Os métodos de aquisição de imagem que investigam a vascularização da face muitas vezes são caros e acrescentam risco à condição do paciente. A ultrassonografia é um método de imagem que não oferece risco ao paciente, sendo acessível e realizado em tempo real. A intensidade do fluxo sanguíneo de uma determinada estrutura pode ser medida pelo modo Doppler e alterações do padrão de normalidade indicam uma possível deficiência na nutrição dos tecidos compreendidos, podendo mesmo levar o clínico a prever futuras afecções. O objetivo neste estudo foi captar a vascularização normal da face, por meio da ultrassonografia modo B e Doppler de modo a se propor um mapeamento dos principais vasos arteriais. Foi possível, utilizando-se transdutores linear e endocavitário proceder-se ao estudo da vascularização da face. Foram obtidos dados referentes à vascularização da face que permitissem a análise da hemodinâmica dos tecidos. Foram estudados três vasos de diâmetro reduzido (0,60mm a. angular; 0,55mm a. palatina maior; 0,45mm a. infraorbital), sendo que nestes foi possível adquirir gráficos de onda de velocidade de fluxo e, consequentemente, obter-se a velocidade de pico sistólico (VPS) e o índice de resistividade (IR). / The study of the blood supply of the facial tissues is important due to oral and maxillofacial surgery as for operations that make use of flaps. The proper restoration of the perfusion is essential to the success of these procedures. The image methods that investigate the vasculature of the face are often costly and add risk to the patients condition. Ultrasound is an imaging method that offers no risk, is affordable and is performed in real time. The intensity of blood flow of a given structure can be measured by Doppler mode and changes in the normal range can indicate a deficiency in the nutrition of tissues end even influence the clinician to predict future conditions. The aim of this study was to access the normal vasculature of the face through ultrasound B-mode and Doppler in order to propose a mapping of the arterial vessels. It was possible, using the linear and endocavitary probes to study the vascularity of the face. Data was obtained allowing the analysis of the tissue hemodynamics. It was possible to access three arteries of small diameter (0,60mm angular artery; 0,55mm greater palatine artery; 0,45mm infraorbital artery) and in all cases graphics of wave flow velocity. Therefore, the resistivity index (RI) and systolic peak velocity (SPV) could also be computed.
150

Avaliação morfologica e funcional dos musculos mastigatorios em crianças com mordida cruzada posterior / Evaluation morphological and functional of masticatory muscles in children with posterior crossbite

Andrade, Annicele da Silva 22 February 2008 (has links)
Orientador: Maria Beatriz Duarte Gavião / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T08:24:27Z (GMT). No. of bitstreams: 1 Andrade_AnniceledaSilva_M.pdf: 1217819 bytes, checksum: 40973029a7720e6b55051a0ee1c9e063 (MD5) Previous issue date: 2008 / Resumo: O objetivo da presente pesquisa foi realizar uma revisão sistemática sobre as principais alterações funcionais associadas à mordida cruzada posterior (MCP), bem como verificar parâmetros morfológicos e funcionais de crianças com MCP, por meio de avaliação do lado preferido da mastigação, espessura muscular e atividade eletromiográfica (EMG) dos músculos mastigatórios. Para a revisão sistemática foram utilizados os descritores ¿crossbite¿ and ¿bite force¿ or ¿surface EMG¿ or ¿TMD¿. A pesquisa resultou em 494 artigos, dos quais 8 foram selecionados após passar pelos os critérios de exclusão. A revisão demonstrou que crianças com MCP apresentam menor força de mordida, função muscular assimétrica durante a mastigação e máxima intercuspidação e maior prevalência de sinais e sintomas de disfunção temporomandibular (DTM). No capítulo 2, a espessura muscular e atividade EMG dos músculos masseter e temporal anterior na posição de repouso e máxima intercuspidação foram avaliadas em crianças, de ambos os gêneros (7-10 anos), divididas nos seguintes grupos: Grupo com MCP (n=20); e Grupo com oclusão normal (ON, n=16). Para avaliação da atividade EMG e espessura muscular foram utilizados eletrodos de superfície e equipamento de ultrasom, respectivamente, nas posições de repouso e máxima intercuspidação. Os dados dos exames foram comparados entre os grupos e entre os lados dentro de cada grupo. A correlação entre espessura muscular e atividade EMG também foi avaliada. Os resultados demonstraram uma maior atividade EMG no masseter do lado cruzado em relação ao lado não-cruzado no grupo com MCP durante a máxima intercuspidação. Na avaliação da espessura muscular, não houve diferença estatística entre os lados e nem entre os grupos. Houve correlação positiva entre a atividade EMG e espessura muscular somente no masseter esquerdo do grupo controle. No capítulo 3, o lado preferido, as características dos ciclos mastigatórios e a atividade EMG durante a mastigação foram avaliados em crianças com MCP (n=20) e com ON (n=14). O lado preferido da mastigação foi avaliado através do método visual ¿spot-checking¿ e a atividade EMG dos músculos mastigatórios foi registrada com eletrodos de superfície durante a mastigação habitual por 20s, período em que também foi quantificada a duração e a freqüência do ciclo mastigatório. Os dados foram comparados entre os lados e entre os grupos. A correlação entre a atividade EMG e duração dos ciclos também foi avaliada. Os resultados demonstraram que os 2 grupos, MCP e ON, não apresentaram um lado preferido da mastigação. A atividade EMG dos músculos mastigatórios, a velocidade e duração dos ciclos não diferiram entre os grupos. Houve correlação positiva significativa entre atividade EMG do masseter e a duração dos ciclos no grupo MCP. De acordo com os estudos, conclui-se que crianças com MCP apresentam atividade EMG assimétrica do masseter durante a máxima intercuspidação, porém esta assimetria não resultou em alterações na espessura muscular. Além disso, as características morfológicas e funcionais da mastigação avaliadas na presente pesquisa não diferiram entre crianças com e sem MCP / Abstract: The aim of the present research was to perform a systematic review about the major functional changes associated with posterior crossbite (PCB), as well as to verify morphological and functional parameters of children with PCB, through the evaluation of the preferred chewing side, muscle thickness and electromyographic (EMG) activity of masticatory muscles. For the systematic review the descriptors "crossbite" and "bite force" or "surface EMG" or "TMD" were used. The search resulted in 494 articles, in which 8 met the inclusion criteria. The review showed that children with posterior crossbite presented reduced bite force, asymmetrical muscle function during chewing or clenching, and more prevalence of signs and symptoms of temporomandibular disorders (TMD). In chapter 1, the thickness and EMG activity of the muscles masseter and anterior temporalis in rest position and maximum clenching were evaluated in children, of both sexes (7-10 years), divided into the following groups: Group with posterior crossbite (n=20); and group with normal occlusion (NOccl, n=16). In assessing the EMG activity and muscle thickness surface electrodes and ultrasound equipment were used, respectively, in rest position and maximum clenching. Data were compared between groups and between right and left sides within each group. The correlation between muscle thickness and EMG activity was also evaluated. The results showed a higher EMG activity in the masseter of the crossbite side in relation to the non-crossbite side in the group PCB during maximum clenching. In the evaluation of muscle thickness, there was no statistical difference between sides, nor between groups. There was a positive correlation between the EMG activity and muscle thickness only in the left masseter in the NOccl group. In chapter 2, the preferred chewing side, chewing rate and EMG activity during mastication were evaluated in children with PCB and with normal occlusion (NOccl, n=14). The preferred chewing side was evaluated using a visual spot-checking method and the EMG activity of masticatory muscles was recorded with bipolar surface electrodes during habitual mastication for 20s, period in which the duration and velocity of each masticatory cycle were quantified. Data were compared between sides and between groups. The correlation between EMG activity and cycle duration was also evaluated. The results demonstrated that both groups, PCB and NOccl, did not present a preferred chewing side. The EMG activity of masticatory muscles, the chewing rate and cycle duration did not differ between groups. The correlation between chewing rate and EMG activity of masseter was statistically significant in the PCB group. It was concluded that children with PCB present asymmetric muscle activity of the masseter muscle during maximal clenching, but this asymmetry did not result in alterations in the muscle thickness. Moreover, the morphological and functional characteristics of mastication evaluated in the present research did not differ between children with or without PCB / Mestrado / Odontopediatria / Mestre em Odontologia

Page generated in 0.0445 seconds