Spelling suggestions: "subject:"ultrasonography"" "subject:"ltrasonography""
311 |
Estudo comparativo entre radiologia convencional e ultrassonografia modo B e Doppler na avaliação de doenças torácicas extracardíacas em cães e gatos / Comparative study between conventional radiology and B-mode and Doppler ultrasonography in the evaluation of non-cardiac thoracic diseases in dogs and catsPires, Sâmara Turbay 17 February 2011 (has links)
Made available in DSpace on 2015-03-26T13:46:57Z (GMT). No. of bitstreams: 1
texto completo.pdf: 4087144 bytes, checksum: 301891873f86d06986fcdaf367d00350 (MD5)
Previous issue date: 2011-02-17 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / This study compared the radiographic and B-mode and Doppler ultrasonographic findings of the thorax, excluding the heart, of dogs (27) and cats (2) whose thoracic radiographys revealed an potential acoustic window. The aim of this study was to identify advantages and limitations of each technique, besides to determine if these additional informations had impact on differential diagnoses and outcomes. The B-mode ultrasonographic examination showed the following advantages: better estimative of the amount of pleural effusion, qualitative informations regarding its nature, identification of submerged structures, differentiation between solid and cystic nodules, as well as definition of its location in the lung parenchyma or other thoracic compartments. The Power Doppler ultrasonography allowed to assess the blood pattern supply of nodules and masses, and differentiate between vessels and fluid bronchograms. Ultrasonographic limitations were based in the impossibility of evaluation of the lung parenchyma in the absence of an acoustic window and requirement to be guided by previous radiographic examination. The radiographic advantages were the possibility of location of pulmonary lesions in any depth in the absence of pleural effusion and mainly because provided a panoramic view of the thoracic cavity involvement. Informations obtained by the ultrasonographic examination provided impact on the differential diagnosis in 62.06% of the cases. In 27.5% of the cases, additional informations also influenced the outcome. / Este estudo comparou os achados radiográficos e ultrassonográficos modo B e Doppler da cavidade torácica, excluindo o coração, em animais das espécies canina (27) e felina (2), nos casos onde as radiografias torácicas revelaram formação de janela acústica em potencial. O intuito do projeto foi apontar vantagens e limitações de cada uma das técnicas, além de determinar se as informações adicionais tiveram impacto nos diagnósticos diferenciais e nos desfechos. O exame ultrassonográfico modo B apresentou as seguintes vantagens: melhor estimativa da quantidade de efusão pleural, informações qualitativas quanto a sua natureza e identificação de estruturas imersas, além da determinação da natureza sólida ou cística de nódulos, bem como a definição de sua localização no parênquima pulmonar ou em outros compartimentos torácicos. A ultrassonografia Doppler de Amplitude permitiu a avaliação do padrão de irrigação sanguínea de nódulos e massas e a diferenciação entre vasos e broncogramas fluidos. As limitações da técnica ultrassonográfica recaíram na impossibilidade de avaliação do parênquima pulmonar na ausência de janela acústica e, portanto, da necessidade de ser guiada pelo exame radiográfico prévio. As vantagens do exame radiográfico evidenciaram-se na possibilidade de localização de lesões pulmonares em qualquer profundidade na ausência de efusão pleural e principalmente pelo fato de proporcionar uma visão panorâmica da cavidade torácica. As informações obtidaspor meio do exame ultrassonográfico proporcionaram impacto no diagnóstico diferencial de 62,06% dos casos. Em 27,5% dos casos, as informações adicionais influenciaram também o desfecho.
|
312 |
Uso da análise computacional de imagens ultra-sonográficas na avaliação da função luteal em bovinos / Use of computer-assisted ultrasound image analysis to evaluate bovine luteal functionSiqueira, Luiz Gustavo Bruno 27 February 2007 (has links)
Made available in DSpace on 2015-03-26T13:55:29Z (GMT). No. of bitstreams: 1
texto completo.pdf: 2231606 bytes, checksum: b29196071c5e84791111ab5a3acb8e50 (MD5)
Previous issue date: 2007-02-27 / Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Ultrasound image attributes, quantified by computer-assisted analysis, are a good indication of corpora lutea (CL) physiological and functional status. However, a standard method to capture and processing images has not been established for bovine. The purposes of this research were to establish a methodology for capture, processing and computer-assisted analysis; to evaluate CL morphological and echotexture changes throughout a natural estrous cycle or a luteolysis induced estrous cycle; and to determine whether computer-assisted analysis is efficient or not for embryo recipient selection. In the first study, evaluations were made of methods to capture images, systems of capture and the minimum representative sample area. For transrectal (TR) images, the minimum established area was 0.25 cm² (4.42% of the major area). A correlation was found in mean pixel values (r = 0.9930; P<0.001) and heterogeneity (r = 0.9861; P<0.001) between images videotaped or direct digitized. In a second study, two experiments were developed: natural estrous cycle and induced luteolysis (day 10) estrous cycle. Echotexture parameters of the CL, in the expt. 1, were analyzed after data adjustment to the onset of luteolysis. In both experiments, mean pixel values did not differ throughout the days of the cycle (P>0.10) and there was no correlation between plasma progesterone and mean pixel value (r = -0.39 and r = -0.28; P>0.10). Pixel heterogeneity varied through the days in a cycle with natural luteolysis (P<0.01), but did not in a luteolysis induced cycle (P>0.10). Correlations were observed between pixel heterogeneity and plasma P4 in both of the experiments (r = - 0.69 and r = -0.48; P<0.05). In a third study, embryo recipients (n=259) were examined by transrectal ultrasonography on the embryo transfer day (ET). The same type of analysis was done to assess image attributes, as previously tested in the 1st and 2nd studies. Good quality embryos (grades 1 and 2) collected after conventional superovulatory treatment (MOET; n=94) or in vitro produced (IVP; 88) were transferred to the recipients. Pregnancy rates were 56.4% and 30.2% for MOET and IVP, respectively. Plasma progesterone concentration values were greater in the recipients later diagnosed as pregnant, than in non-pregnant (5.88±0.77 vs 3.98±0.48 ng/mL, respectively; P<0.05). There was no difference in plasma P4 between pregnant and non pregnant IVP recipients (3.97±0.57 vs 3.52±0.23; P>0.10). Corpus luteum and luteal tissue area did not differ between pregnant and non-pregnant animals. In addition, no difference in mean pixel values (71.80±1.29 vs 71.19±1.14; P>0.10; scale of 0 to 255) and heterogeneity (14.80 vs 14.52; P>0.10) was observed, between pregnant and non pregnant MOET or IVP recipients. Echotexture parameters (mean pixel value and heterogeneity) showed correlations with plasma P4 (0.17 and 0.18, respectively; P<0.01). In conclusion, differences between capture, processing and image analysis methods should be considered in luteal echotexture evaluation; if on one hand, pixel heterogeneity in ultrasound images is a strong indicative of functional status and steroidogenic capacity of luteal gland, on the other hand, mean pixel values are a poor indicator of these characteristics. Finally, in this approach computer-assisted analysis of ultrasound images was not efficient on embryo recipient selection, probably due to other variables which strongly influence overall pregnancy rate. / Atributos de imagens de ultra-som, quantificados por análise computacional, têm o potencial de indicar o status fisiológico e funcional de corpos lúteos (CL). Ainda não foi estabelecido, contudo, um padrão de captura e processamento das imagens para bovinos. Os objetivos desta pesquisa foram estabelecer uma metodologia para aquisição, processamento e análise computacional de imagens; avaliar as mudanças morfológicas e de ecotextura do CL ao longo do ciclo estral natural ou após indução da luteólise; e verificar a eficiência da técnica de análise computacional na seleção e triagem de receptoras de embrião. No primeiro estudo, foram avaliados métodos de geração de imagens, sistemas de captura e área de amostragem mínima representativa. Para imagens geradas por via transretal (TR), a área mínima estabelecida foi de 0,25 cm² (4,42% de variação em relação à maior área). Foi constatada uma correlação nos valores médios de pixel (r=0,99; P<0,001) e heterogeneidade (r=0,99; P<0,001) entre imagens gravadas em fitas VHS e com digitalização direta. No segundo estudo, foram realizados dois experimentos: avaliação do ciclo natural ou após luteólise induzida no 10º dia do ciclo. No experimento 1, os parâmetros de ecotextura do CL foram analisados após o ajuste dos dados para o momento da luteólise. Em ambos os experimentos, o valor médio dos pixels não variou em função dos dias (P>0,10) e não foi observada relação entre a concentração de progesterona [P4] plasmática e este parâmetro (r = -0,39 e r = -0,28; P>0,10). A heterogeneidade variou em função dos dias na luteólise natural (P<0,01), mas não na induzida (P>0,10). Ainda, foram observadas relações entre heterogeneidade e a [P4] plasmática nos dois experimentos (r = -0,69 e r = -0,48; P<0,05). No terceiro estudo, receptoras de embrião (n=259) foram examinadas por ultra-sonografia no dia da transferência de embriões (TE). Foi feito o mesmo tipo de análise dos atributos das imagens previamente testado nos estudos 1 e 2. Foram transferidos embriões de boa qualidade (1 e 2) obtidos por superovulação convencional (TE; n=94) ou produzidos in vitro (PIV; n=88). As taxas de gestação foram de 56,4% e 30,2% para embriões TE e PIV, respectivamente. Nas receptoras TE, os valores de [P4] plasmática foram maiores nos animais posteriormente diagnosticados como gestantes que nos não gestantes (5,88±0,77 vs 3,98±0,48 ng/mL, respectivamente; P<0,05). No entanto, nas receptoras PIV não houve diferenças entre gestantes ou não (3,97±0,57 vs 3,52±0,23; P>0,10). A área do CL e área de tecido luteal entre gestantes e não gestantes não diferiu. Não foram observadas diferenças nos valores médios (71,80±1,29 vs 71,19±1,14; P>0,10; escala de 0 a 255) e na heterogeneidade (14,80 vs 14,52; P>0,10) dos pixels, em receptoras gestantes ou não gestantes, que receberam embriões TE ou PIV. Os parâmetros de ecotextura (média dos pixels e heterogeneidade) apresentaram baixas relações com a [P4] plasmática (0,17 e 0,18; respectivamente; P<0,01). Conclui-se que as diferenças nos métodos de captura, processamento e análise de imagens devem ser consideradas quando se avalia a ecotextura luteal; a heterogeneidade, ao contrário do valor médio, de pixels em imagens ultrasonográficas é indicativo de funcionalidade e capacidade esteroidogênica da glândula luteal; e a análise computacional de imagens não foi eficiente no auxílio à seleção e triagem de receptoras de embriões, possivelmente pela forte influência que outras variáveis exercem sobre a taxa de gestação final.
|
313 |
Dopplervelocimetria da artéria oftálmica em gestantes pré-eclâmpticas com recém-nascidos portadores de restrição de crescimentoFreitas, Marta Alves de [UNESP] 25 February 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:06Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-25. Added 1 bitstream(s) on 2016-06-07T17:16:38Z : No. of bitstreams: 1
000860332.pdf: 691560 bytes, checksum: dbeaf85cedbc67660b6f5be6096672ed (MD5) / Introdução: Dentre as síndromes hipertensivas que acometem a gestação, a pré-eclâmpsia (PE) é a principal causa de mortalidade e morbidade materna a curto e longo prazo, e de complicações perinatais como prematuridade, restrição do crescimento e óbito. O exame de fundo de olho reflete as alterações decorrentes do vasoespasmo sistêmico, alteração básica na fisiopatologia da doença. O Doppler das artérias oftálmicas é um exame reprodutível e não invasivo, constituindo-se em um método objetivo que diferencia as formas de manifestação da hipertensão entre si, aprimora a compreensão da fisiopatologia da pré-eclâmpsia e identifica a gravidade da doença, diretamente relacionada com o comprometimento do sistema nervoso central. Objetivo: Identificar se existe relação entre as alterações verificadas no Doppler da artéria oftálmica de gestantes portadoras de PE e a ocorrência de restrição de crescimento fetal. Sujeitos e métodos: Realizou-se estudo de corte transversal em uma população de 75 gestantes com diagnóstico de PE, que tiveram a resolução da gestação no Hospital Regional do Gama - Distrito Federal e cujos recém-nascidos foram classificados de acordo com a adequação do peso para a idade gestacional (PIG - pequeno para a idade gestacional e não PIG), segundo a tabela de Lubchenco. O exame dopplervelocimétrico da artéria oftálmica foi realizado em equipamento Toshiba Nemio 17, com transdutor linear na frequência de 10 MHz, determinando-se os seguintes parâmetros: índice de resistência (IR), índice de pulsatilidade (IP), pico de velocidade sistólica (PVS), velocidade diastólica final (VDF) e razão entre picos de velocidade (RPV). A análise estatística foi realizada utilizando os métodos ANOVA e Qui-quadrado. Os resultados foram considerados estatisticamente significativos quando apresentaram valores de p <0,05. Resultados: A análise das características clínicas maternas, segundo... / Introduction: Among hypertensive disorders that affect pregnancy, preeclampsia (PE) is the leading cause of mortality in short and long-term maternal morbidity and also perinatal complications such as premature birth, growth restriction and death. The examination of eye reflects changes arising from systemic vasospasm, a basic change in the disease pathophysiology. The Doppler of ophthalmic arteries is a reproducible and noninvasive, thus becoming an objective method that sets the manifestations of hypertension among themselves, enhances the understanding of the preeclampsia pathophysiology and identifies the severity of the disease, directly related to the central nervous system compromising. Objective: To identify if there is a relationship between changes in the Doppler of the ophthalmic artery of pregnant women with PE and the occurrence of fetal growth restriction. Subjects and Methods: Across sectional study in a population of 75 pregnant women with a diagnosis of PE, who had pregnancy resolution at Regional Hospital of Gama - Federal District and whose newborns were classified according to their weight for gestational age (SGA - small for gestational age and not SGA) according to Lubchenco table. The dopplervelocimetry of the ophthalmic artery was performed in 17 Nemio Toshiba equipment with linear transducer in the frequency of 10 MHz and, the following parameters were determined: resistance index (RI), pulsatility index (PI), systolic velocity peak(SVP), end-diastolic velocity (EDV) and velocity ratio peak (VRP). Statistical analyses were performed using ANOVA and Chi-square test. The results were considered statistically significant with p values <0.05. Results: Analysis of maternal clinical characteristics, according to the newborns classification (Not SGA and SGA), showed no significant difference in maternal age (27.7+6.8 years vs 29.5+7, 4 years), parity (48.2% vs 50%) and the rate of cesarean delivery (84.7% vs 100%). ...
|
314 |
Avaliação da da reprodutibilidade da mobilidade diafragmática pelo método ultrassonográfico indireto / Reproducibility assessment of the diaphragmatic mobility by indirect ultrasonographic methodGrams, Samantha Torres 11 March 2011 (has links)
Made available in DSpace on 2016-12-06T17:07:30Z (GMT). No. of bitstreams: 1
SAMANTHA.pdf: 876616 bytes, checksum: c74d2b2ad0681e7f9b3ceacfe3783d11 (MD5)
Previous issue date: 2011-03-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objetive: Assessing the reproducibility of the ultrasonographic measurement of craniocaudal displacement of the left branches of the portal vein as a method to evaluate the right hemidiaphragm mobility in healthy young adults. Methods: Forty-one healthy subjects were selected, with age range between 20 and 30 years. The participants of the study were underwent physical examination to measure the cardiorespiratory parameters and anthropometric variables, pulmonary function test, respiratory muscle strength assessment and ultrasonographic evaluation of the the right hemidiaphragm mobility. The implementation and interpretation of ultrasound imaging were performed by two observers (A and B), independently, at two different times (1st and 2nd test). The intra-observer and inter-observer reproducibility and the repeatability of ultrasound measurements were determined by intraclass correlation coefficient (ICC[2,1]) with 95% confidence interval (CI). The Bland & Altman plot was also used, because it allows better visualization of agreement between measures. The level of significance for statistical treatment was 5% (p0,05). Results: From the forty-one subjects participated in study, 27 were females (66%) and 14 males (34%), with means age of 24,8 ± 2,7 years. In the analysis of inter-observer reproducibility, the ICC[2,1] indicated "high correlation" for both the 1st and the 2nd test (ICC[2,1] = 0.83, 95% CI = 0.70 to 0.91 and ICC[2,1] = 0.79, 95% CI = 0.61 to 0.89, respectively). In the analysis of intra-observer reproducibility, the ICC[2,1] indicated "moderate correlation" for observer A (ICC[2,1] = 0,69, 95% CI = 0.45 to 0.84) and for observer B (ICC[2,1] = 0.65, 95% CI = 0.39 to 0.81). In analyzing the repeatability of ultrasound measurements, the ICC[2,1] indicated a "high correlation" for all tests performed (ICC[2,1] = 0.86, 0.80, 0.71, 0.79, p<0.001). Conclusion: The ultrasonographic measurement of craniocaudal displacement of the left branches of the portal vein is a reproducible method for indirect assessment of the right hemidiaphragm mobility in healthy young adults. / Objetivo: Analisar a reprodutibilidade da medida ultrassonográfica do deslocamento crânio-caudal do ramo esquerdo da veia porta como método de avaliação da mobilidade do hemidiafragma direito de adultos jovens saudáveis. Métodos: Foram avaliados 41 indivíduos saudáveis, com idade entre 20 e 30 anos. Os participantes do estudo foram submetidos a exame físico para mensuração dos parâmetros cardiorrespiratórios e das variáveis antropométricas, prova de função pulmonar, avaliação da força muscular respiratória e avaliação ultrassonográfica da mobilidade do hemidiafragma direito. A execução e interpretação dos exames de ultrassom foram realizadas por dois observadores (A e B), de forma independente, em dois momentos distintos (1º e 2º exame). A reprodutibilidade intra e interobservadores e a repetibilidade das medidas ultrassonográficas foram determinadas pelo coeficiente de correlação intraclasse (ICC[2,1]) e pelo intervalo de confiança (IC) de 95%. A disposição gráfica de Bland & Altman também foi utilizada por permitir melhor visualização da concordância entre as medidas. O nível de significância adotado para o tratamento estatístico foi de 5% (p0,05). Resultados: Dos 41 sujeitos, 27 pertenciam ao sexo feminino (66%) e 14 ao sexo masculino (34%); com média de idade de 24,8 ± 2,7 anos. Na análise da reprodutibilidade interobservadores, o ICC[2,1] indicou alta correlação tanto para o 1º quanto para o 2º exame ultrassonográfico (ICC[2,1] = 0,83, IC 95% de 0,70 a 0,91 e ICC[2,1] = 0,79, IC 95% de 0,61 a 0,89, respectivamente). Na análise da reprodutibilidade intra-observador, o ICC[2,1] indicou moderada correlação para o observador A (ICC[2,1] = 0,69, IC 95% de 0,45 a 0,84) e para o observador B (ICC[2,1] = 0,65, IC 95% de 0,39 a 0,81). Na análise da repetibilidade das medidas ultrassonográficas, o coeficiente de correlação intraclasse indicou alta correlação para todos os exames realizados (ICC[2,1] = 0,86; 0,80; 0,71; 0,79, p<0,001). Conclusão: A medida ultrassonográfica do deslocamento crânio-caudal do ramo esquerdo da veia porta demonstrou ser um método reprodutível para avaliação indireta da mobilidade do hemidiafragma direito de adultos jovens saudáveis.
|
315 |
Efeitos da estimulação ultra-sônica pulsada e contínua no processo cicatricial de ratos submetidos à celiotomia / Pulsed and continuos ultrasound stimulation in rats healing celiotomyOlsson, Débora Cristina 23 February 2005 (has links)
Made available in DSpace on 2016-12-08T16:24:03Z (GMT). No. of bitstreams: 1
PGCV05MA002.pdf: 1691913 bytes, checksum: 713d1f5baaea9131f22eecaf7a6e63bc (MD5)
Previous issue date: 2005-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work two protocols of ultrasound therapy were used, in way continuous
and pulsed, to evaluate the cicatrization of surgical wounds in mice submitted the
celiotomy. Forty five female mice were used, rantomized in 3 experimental groups
with 15 animals each group. The evaluation healing was accomplished by
morphometry being evaluated the proportion size of the representatives tissue and
cellular of samples of obtained tissues of the abdominal wall in time zero, 48, 96 and
144 hours after celiotomy. Twenty-four hours after the surgical intervention, the
ultrasound application began on the surgical wound. The application of US in the
pulsed way resulted larger proportion polymorphonuclear size, fibroblasts and
angiogenesis at the 48 hours when compared with the group control and the group
that it received ultrasound application in the continuous way (p 0,05). T hose resul ts
suggest that the application of US in the pulsed way can be recommended in the
treatment of surgical wounds in the abdominal cavity / Neste trabalho foram utilizados dois protocolos de ultra-som terapia, nos
modos contínuo e pulsado, para avaliar a cicatrização de feridas cirúrgicas em ratos
submetidos a celiotomia. Foram utilizados 45 ratos, fêmeas, separados aleatoriamente
em 3 grupos experimentais com 15 animais por grupo. A avaliação da cicatrização foi
realizada por esteriometria avaliando-se a proporção volumétrica dos constituintes
tissulares e celulares de amostras de tecidos obtidos da parede abdominal às zero, 48,
96 e 144 horas após celiotomia. Vinte e quatro horas após a intervenção cirúrgica
iniciou-se a aplicação de ultra-som sobre a ferida cirúrgica. A aplicação de US no
modo pulsado determinou maior proporção volumétrica de polimorfonucleares,
fibroblastos e angiogênese às 48 horas quando comparado com o grupo controle e o
grupo que recebeu aplicação de ultra-som no modo contínuo (p 0,05). Esses
resultados sugerem que aplicação de US, no modo pulsado pode ser recomendado
como adjuvante no tratamento de feridas cirúrgicas na parede abdominal
|
316 |
Anestesia peridural lombossacral em cães guiada em tempo real pela ultrassonografia / Real-time ultrasound-guided lumbosacral epidural anesthesia in dogsCredie, Leonardo de Freitas Guimarães Arcoverde [UNESP] 27 March 2018 (has links)
Submitted by Leonardo de Freitas Guimarães Arcoverde Credie (leo_credie@yahoo.com.br) on 2018-05-14T22:08:59Z
No. of bitstreams: 1
Tese completa.pdf: 11151658 bytes, checksum: de6b02496163d822cbea198d463ac878 (MD5) / Approved for entry into archive by Sulamita Selma C Colnago null (sulamita@btu.unesp.br) on 2018-05-15T14:14:48Z (GMT) No. of bitstreams: 1
credie_lfga_dr_bot.pdf: 11151658 bytes, checksum: de6b02496163d822cbea198d463ac878 (MD5) / Made available in DSpace on 2018-05-15T14:14:48Z (GMT). No. of bitstreams: 1
credie_lfga_dr_bot.pdf: 11151658 bytes, checksum: de6b02496163d822cbea198d463ac878 (MD5)
Previous issue date: 2018-03-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo clínico prospectivo e aleatório objetivou descrever a sonoanatomia do espaço peridural lombossacral (LS) e avaliar e comparar a técnica guiada em tempo real com auxílio da ultrassonografia (US), em relação à palpação das referências anatômicas, para anestesia peridural em cães normais (escore de condição corporal – ECC ≤ 5) ou obesos (ECC ≥ 6). Para tal 72 animais provenientes de tutores, foram subdivididos igualmente em quatro grupos: PG1 e PG2 (Grupo Palpação 1 em animais normais e Grupo Palpação 2 em animais obesos, respectivamente), nos quais a técnica de anestesia peridural baseou-se nas referências anatômicas e perda de resistência à administração do fármaco e grupos USG1 e USG2 (Punção Guiada por US1 em animais normais e Punção Guiada por US2 em animais obesos, respectivamente), nos quais a técnica de anestesia peridural foi guiada exclusivamente pelo US. Para identificação das estruturas, utilizaram-se os cortes sagital, parassagital oblíquo e transversal. Aferiu-se a distância entre a pele e o ligamentum flavum (LF) nos grupos USG1 e USG2. Para confirmação exata da punção guiada por US, observaram-se a movimentação da agulha no momento da punção do LF e o fluxo de anestésico administrado, através da migração pelo canal peridural. Após a punção, confirmou-se a eficácia do bloqueio locorregional no período perioperatório. A utilização da ultrassonografia possibilitou a visualização das estruturas do espaço peridural LS, bem como o momento exato da punção e o fluxo do anestésico local nos espaços intervertebrais entre a 6ª (L6) e 7ª vértebras (L7), ou entre a 5a (L5) e 6a vértebras (L6) em todos os pacientes dos grupos USG1 e USG2, em ambos os cortes. As medidas entre pele e LF foram iguais nos cortes sagital e transversal, sendo 2,45 0,48 cm e 2,42 0,49 cm respectivamente para USG1 e 3,07 0,74 cm e 3,06 0,73 cm respectivamente para USG2. Nos grupos guiados por US, o número de contato entre agulha e tecido ósseo (USG1= 0,16 0,38 e USG2= 0,88 1,67) e refluxo de sangue na agulha (USG1= 5,5% e USG2= 0%) foram menores do que nos grupos guiados por palpação (contato agulha/osso: PG1= 0,88 1,67 e PG2= 2,72 2,02; refluxo de sangue: PG1= 11,1% e PG2= 22,2%). Concluiu-se que a anestesia peridural LS guiada por US possibilitou observar a sonoanatomia da região, acompanhar a introdução da agulha até o correto posicionamento no espaço peridural e visualizar a administração do anestésico local em tempo real, de forma independente de palpação de estruturas anatômicas, tanto em animais normais como em obesos, o que é uma vantagem ao se realizar anestesia peridural em animais com ECC ≥ 6. / This prospective and randomized clinical study aimed to describe the sonoanatomy of the lumbosacral epidural space and to evaluate and compare the real time guided ultrassonography (US) technique in comparison to palpation of anatomical references, to perform epidural anesthesia in normal (body condition score ≤ 5) or obese (body condition score ≥ 6). Seventy two client dogs were equally distributed in four groups, PG1 and PG2 (Palpation group 1 in normal animals and Palpation group 2 in obese animals, respectively), in which epidural anesthesia technique was based on palpation of anatomical references and loss of resistance to injection, and groups USG1 e USG2 (Ultrasound guided group 1 in normal animals and ultrasound guided group 2 in obese animals, respectively), in which the technique was guided only by US. Structures were identified in the sagittal, parasagittal oblique and transverse sections. The distance between skin and ligamentum flavum (LF) was measured in groups USG1 and USG2. Correct introduction and position of the needle in the epidural space and the flow of local anesthetic through the epidural canal was confirmed by US. The effectiveness of epidural anesthesia was confirmed in the perioperative period. With the use of US it was possible to define the sonoanatomy and to observe both the correct placement of the needle in the lumbosacral epidural space and the local anesthetic flowing between the sixth (L6) and seventh (L7) or fifth (L5) and sixth lumbar vertebrae in all dogs of the USG1 and USG2 groups, both in parasagittal oblique and in transversal approaches. The distances between skin and LF at the sagittal and transversal approaches were 2.45 0.48 cm and 2.42 0.49 cm respectively for USG1 and 3.07 0.74 cm and 3.06 0.73 cm respectively for USG2. The needle to bone contact events (USG1= 0.16 0.38 and USG2= 0.88 1.67) and presence of blood in the syringe (USG1= 5.5% e USG2= 0%) were lower than the palpation guided epidural anesthesia (needle to bone contacts: PG1= 0.88 1.67 and PG2= 2.72 2.02; blood in the syringe: PG1= 11.1% and PG2= 22.2%). The use of US provided accurate information about sonoanatomy of the LS epidural space in dogs, guided the positioning for the introduction of the needle without palpation of the anatomical structures, enabled to observe the correct injection of local anesthetic into the epidural space even in obese patients, and reduced the number of attempts to perform epidural anesthesia when compared to palpation of anatomical landmarks and loss of resistance technique. / 049/2015
|
317 |
Elastografia acoustic radiation force impulse (ARFI), doppler e ultrassonografia contrastada do baço canino /Maronezi, Marjury Cristina. January 2016 (has links)
Orientador: Marcus Antônio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Coorientador: Júlio Carlos Canola / Banca: Leandro Zuccolotto Crivellenti / Banca: Eliandra Antônia Pires Buttler / Resumo: O baço é um órgão que desenvolve inúmeras funções importantes no organismo e é um dos principais locais para o desenvolvimento de tumores primários, metastáticos e afecções do sistema hematopoiético, por isso realizar uma avaliação apurada neste órgão é de suma importância, em Medicina veterinária, particularmente em cães devido à importância econômica, afetiva e de similaridade cientifica para o homem. Todavia, a maioria dos métodos utilizados para o diagnóstico conclusivo de enfermidades esplênicas são métodos invasivos, sendo que os nãos invasivos perdem em sensibilidade e especificidade, dificultando que se proceda a um correto diagnóstico. Sendo assim, este estudo prospectivo visou avaliar a aplicabilidade das novas técnicas ultrassonográficas para avaliação esplênica de caninos, utilizando a elastografia ARFI (qualitativa e quantitativa), Doppler e ultrassonografia por contraste com microbolhas, com o intuito de determinar valores ainda não descritos na veterinária, as quais forneçam subsídios suficientes para se obter um diagnóstico conclusivo sobre a condição esplênica, nesta espécie. Os resultados obtidos nos cães saudáveis, por meio da ultrassonografia modo B apresentaram-se normais, sendo que na elastografia qualitativa, as porções esplênicas avaliadas apresentaram-se não deformáveis, com parênquima homogêneo de cor cinza escuro (hard). Na elastografia quantitativa os valores médios da velocidade de cisalhamento foram de 2,32 m/s para a cabeça, 2,16 m/s para o corp... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The spleen is an organ develops much important functions in the body and the spleen is one of the main organs prone to the development of primary tumors, metastasis and a broad range of diseases of the hematopoietic system perform assessment of spleen is important. In veterinary medicine, principally in dogs because of economic importance, affective and scientific similarity to humans. However, the most of the methods used for conclusive diagnosis of splenic diseases are invasive methods, noninvasive lose in sensitivity and specificity difficulting proceed to a correct diagnosis. Thus, this study aimed to perform the ultrasound scan of dogs spleen using the elastographic (qualitative and quantitative) Doppler and contrast enhanced ultrasonography. Determining values not described in veterinary, which provide sufficient subsidies to get a conclusive diagnosis of the splenic condition in this species. The results in healthy dogs showed, all splenic segments visualized with the B-mode ultrasonography appeared normal. Different splenic segments examined with qualitative elastography were free of any detectable malformations and the images appeared as homogeneous dark areas. The mean shear velocity values were 2.32 m/s for head, 2.16 m/s for body and 2.25 m/s for tail of the spleen, and they did not vary between the different age groups (P>0.05). In dogs with ehrlichiosis in subclinical phase showed, by B-mode examination, observed splenomegaly with presence of rounded borders and... (Complete abstract click electronic access below) / Mestre
|
318 |
Ultrassonografia convencional e elastografia ARFI (Acoustic Radiation Force Impulse) na avaliação renal de gatos adultos hígidos /Garcia, Paulo Henrique de Souza. January 2016 (has links)
Orientador: Marcus Antônio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Coorientador: Ciblele Figueira de Carvalho / Banca: Eliandra Antonia Pires Buttler / Banca: Leandro Zuccolotto Crivellenti / Resumo: O exame ultrassonográfico convencional tem baixa especificidade para detecção de alterações difusas, no entanto, o aumento da ecogenicidade renal é um dos achados mais comuns em cães e gatos com nefropatia. O objetivo deste estudo foi descrever a técnica de elastografia por irradiação da força de impulso acústico (ARFI) na avaliação dos rins de gatos adultos hígidos, e determinar os valores de referência. Foram incluídos neste trabalho dez gatos de pelo curto, adultos e saudáveis. Após sedação, foi realizada uma ampla tricotomia abdominal, para a realização do exame ultrassonográfico. O exame convencional, em Modo B foi realizado com um transdutor linear de 9,0 MHz usando equipamento de ultrassom ACUSON S2000 / SIEMENS (Siemens, Munique, Alemanha). A ecogenicidade, ecotextura, o tamanho e contornos renais foram avaliados. Com o mesmo transdutor, a elastografia foi realizada utilizando software para comparação das análises qualitativa e quantitativa do método. A elastografia qualitativa detectou a presença de deformidades e as velocidades de cisalhamento em diferentes locais (cranial, média e caudal) das regiões cortical e medular em ambos os rins. Os achados ultrassonográficos foram considerados normais em todos os gatos, sem alterações em arquitetura ou ecogenicidade renal. A elastografia qualitativa demonstrou que o córtex renal era deformável e apresentou áreas cinza escuro homogêneas; pelve renal tinha pouca rigidez (branca); e da medula mostrou um padrão de mosaico. Os r... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Conventional ultrasonography has low specificity to detect diffuse changes, however, increased renal echogenicity is one of the most common findings in dogs and cats with nephropathy. The objective of this study was to describe elastography by acoustic radiation force impulse (ARFI) in the assessment of adult cats' kidneys and determine reference values. Ten healthy adults short hair cats were included. After sedation, abdominal hair was clipped in order to perform ultrasound exams. The conventional examination (B-mode) was performed with a 9.0 MHz linear array transducer ultrasound equipment using ACUSON S2000/Siemens (Siemens, Munich, Germany). Echogenicity, echotexture, size and contours of each kidney were evaluated. With the same transducer, elastography was performed using a software that compares qualitative and quantitative analysis. Qualitative elastography detected deformities and shear wave velocity rates in different portions (cortical and medulla' cranial, media and caudal regions). The sonographic findings were normal in all cats, with no changes in renal architecture or echogenicity. Qualitative elastography showed that renal cortex was softer with dark gray homogeneous areas; renal pelvis presented lower stiffness (white); and medulla showed a mosaic pattern. Shear wave velocities were obtained in cranial, medial, and caudal regions of the cortex and medulla: 2.46 m/s ± 0.45m/s; 2,46m/s ± 0.48 m/ s 2,37 m/s ± 0, 42 m/s (P = 0.795) in the cortex and 1.61 m/s ± ... (Complete abstract click electronic access below) / Mestre
|
319 |
Dinâmica de corpos lúteos em protocolos com redução da dose de FSH na superovulação em ovelhas /Rodriguez, Mariana Garcia Kako. January 2016 (has links)
Orientador: Maria Emilia Franco Oliveira / Banca: Erika da Silva Carvalho Morani / Banca: Wilter Ricardo Russiano Vicente / Resumo: Um dos grandes entraves da MOTE é a ocorrência de falhas no tratamento superovulatório, sendo que uma das causas pode ser a alta dose de FSH, podendo promover regressão prematura dos corpos lúteos e consequentemente uma resposta ineficaz ao tratamento superovulatório. O objetivo deste estudo foi avaliar o efeito da dose de FSH exógeno no tratamento superestimulatório sobre a dinâmica de desenvolvimento e funcionalidade de corpos lúteos em fêmeas ovinas doadoras de embrião. Foram utilizadas 29 ovelhas Santa Inês, as quais foram submetidas à sincronização do estro com um dispositivo intravaginal de progesterona (CIDR®), inserido no Dia 0, permanecendo até o Dia 8. Concomitantemente ao início do protocolo e retirada do dispositivo intravaginal foi administrado um análogo da PGF2α. O tratamento gonadotrófico teve início 48 horas antes da retirada da progesterona (D6), quando as fêmeas foram aleatoriamente divididas em três grupos experimentais de acordo com a dose total de FSH suíno exógeno: G200 (controle, n=8) - 200 mg de FSH; G133 (n=8) - 133 mg de FSH; e G100 (n=8) - 100 mg de FSH. No D6 (1ª aplicação de FSH), as fêmeas receberam também 300 UI de eCG. As avaliações ultrassonográficas Modo-B e Doppler foram realizadas durante o período de luteogênese (D11) até o dia correspondente a videolaparoscopia (D15), com o propósito de acompanhar o desenvolvimento das estruturas lúteas (dimensões), avaliar os índices do fluxo sanguíneo da artéria ovariana (VPS,VDF,IR e IP) e, de avalia... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: One of the major obstacles of MOTE is occurrence of failures in superovulation, and one reason may be the high dose of FSH, which can promote premature regression of the corpus luteum and therefore ineffective response to superovulation. The aim of the present study was to evaluate the effect of exogenous FSH dose in superstimulatory treatment on development dynamic and function of corpora lutea in embryo donor ewes. Twenty-nine Santa Inês ewes were submitted to estrus synchronization with an intravaginal progesterone device (CIDR®), which was inserted on Day 0 and was remain until the Day 8. At the same time the beginning of the protocol and intravaginal device withdrawal was administered an analog of PGF2α. The gonadotropin treatment was commenced 48 hours before the CIDR withdrawal (D6), when females are randomly divided into three groups according to the total dose of exogenous porcine FSH: G200 (control, n = 9) - 200 mg of FSH ; G133 (n = 10) - 133 mg FSH; and G100 (n = 10) - 100 mg of FSH. The total doses were administered in 8 to applications at 12 hour intervals (20, 20, 15, 15, 10, 10, 5 and 5% FSHp). In D6 (1st application FSH), females also received 300 IU of eCG. Evaluations ultrasound mode-B and Doppler were performed during the luteogênese period (D11) until the corresponding day of videolaparoscopy (D15), in order to follow the development of luteal structures (dimensions), evaluate the contents of the artery blood flow ovarian (VPS, EDV, RI and PI), and macros... (Complete abstract click electronic access below) / Mestre
|
320 |
Biometria ocular ultrassonográfica e dopplerfluxometria das artérias oftálmica interna e central da retina em macaco-prego (Sapajus spp) /Rodas, Natália Rodrigues. January 2014 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Banca: Maria Jaqueline Mamprim / Banca: Zara Bortolini / Resumo: O trabalho teve por objetivo avaliar as variáveis biométricas do bulbo ocular utilizando a ultrassonografia ocular modos A e B, bem como realizar a dopplerfluxometria das artérias oftálmica interna e central da retina em macacos-prego. Foram avaliados 18 animais (36 olhos) de macacos-prego (Sapajus spp.) mantidos em cativeiro, sendo 10 fêmeas e 8 machos, clinicamente sadios. As mensurações (em mm) da câmara anterior (D1), espessura da lente (D2), câmara vítrea (D3) e comprimento axial do bulbo ocular (D4) foram feitas, bem como a dopplerfluxometria das artérias oftálmica interna e central da retina, representada por velocidade de pico sistólico (VPS), diastólica final (VDF), ambas em cm/s, índice de resistividade (IR) e de pulsatilidade (IR). As mensurações biométricas médias encontradas no exame ocular ultrassonográfico modo B e modo A foram; Modo B: D1= 2,79 ± 0,19; D2= 3,25 ± 0,22; D3= 10,17 ± 0,48; D4=16,23 ± 0,50; Modo A: D1= 2,16 ± 0,16; D2=3,12 ± 0,14; D3=11,12 ± 0,27; D4= 16,38 ± 0,34. Na dopplerfluxometria da artéria oftálmica interna, os seguintes valores médios das variáveis dopplerfluxométricas foram obtidos: IR=0,71± 0,03; IP=1,30 ± 0,15; VPS=36,89 ± 10,57; VDF=10,52 ± 3,21; e para a artéria central da retina: IR=0,56 ± 0,04; IP=0,81 ± 0,09; VPS= 21,47 ± 7,23; VDF= 9,95 ± 3,31. Os valores de referência de normalidade obtidos poderão auxiliar no diagnóstico de doenças oculares em macacos-prego, bem como poderão ser utilizados em estudos futuros com a presente espécie / Abstract: This study aimed to evaluate the ocular biometric variables using ocular ultrasound A mode and B mode and dopplerfluxometry of the the internal ophthalmic and central retinal arteries. Were evaluated 18 animals (36 eyes) of capuchin monkeys in captivity, 10 females and 8 males, clinically healthy. Measurements of the anterior chamber (D1), lens thickness (D2), vitreous chamber (D3) and axial length of the eyeball (D4) were performed, as well as the dopplerfluxometry of the internal ophthalmic and central retinal arteries, represented by peak systolic velocity (PSV), end diastolic velocity (EDV), resistivity index (RI) and pulsatility index (PI). The biometric measurements averages found in ocular ultrasonography B mode and A mode were : B mode: D1= 2,79 ± 0,19; D2= 3,25 ± 0,22; D3= 10,17 ± 0,48; D4=16,23 ± 0,50; A mode: D1= 2,16 ± 0,16; D2=3,12 ± 0,14; D3=11,12 ± 0,27; D4= 16,38 ± 0,34. In the dopplerfluxometry of the internal ophthalmic, average values of the variables obtained were: RI=0,71± 0,03; PI=1,30 ± 0,15; PSV=36,89 ± 10,57; EDV=10,52 ± 3,21; and the central retina artery were: RI=0,56 ± 0,04; PI=0,81 ± 0,09; PSV= 21,47 ± 7,23; EDV= 9,95 ± 3,31. Reference values obtained may aid in the diagnosis of eye diseases in capuchin monkeys, and may be used in future studies with this species / Mestre
|
Page generated in 0.0602 seconds