• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 566
  • 154
  • 15
  • 14
  • 10
  • 10
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 830
  • 385
  • 223
  • 103
  • 98
  • 95
  • 75
  • 74
  • 70
  • 69
  • 69
  • 67
  • 64
  • 63
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

The use of routine ultrasound in pregnancy with special reference to normal and abnormal foetal growth, information and informed choice and the womens' experiences of the prenatal diagnostic aspects /

Crang-Svalenius, Elizabeth. January 1997 (has links)
Thesis (doctoral)--Lund University, 1997. / Added t.p. with thesis statement inserted.
62

Doppler ultrasound is a useful investigatory tool in the field of obstetrics & gynaecology

Chan, Fung-yee. January 1995 (has links)
Thesis (M.D.)--University of Hong Kong, 1995. / Includes bibliographical references (leaf 208-230). Also available in print.
63

Ultrasound plethysmography : signal processing and application /

Huang, Lingyun. January 2006 (has links)
Thesis (Ph. D.)--University of Washington, 2006. / Vita. Includes bibliographical references (leaves 153-157).
64

Ultrassonografia do bulbo do olho de cães, com diferentes conformações cranianas

Toni, Maria Carolina [UNESP] 20 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-20Bitstream added on 2014-06-13T18:19:51Z : No. of bitstreams: 1 toni_mc_me_jabo.pdf: 258996 bytes, checksum: 041759d510733c85331d9b8673133b75 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Com o presente estudo pretendeu-se conhecer os valores médios para as estruturas intraoculares e compará-los entre cães com diferentes conformações cranianas por meio da ultrassonografia ocular com transdutor de 20 MHz. Foram selecionados 30 cães, adultos, peso corpóreo até 10 kg, machos ou fêmeas, hígidos, atendidos no Hospital Veterinário Governador Laudo Natel - Faculdade de Ciências Agrárias e Veterinárias – UNESP – Câmpus de Jaboticabal. Os cães foram distribuidos em três grupos: G1 – 10 braquicefálicos, G2 - 10 mesocefálicos e G3 - 10 dolicocefálicos. Na análise estatística realizada pelo teste t Student com nível de significância de 5%, não houve diferença entre os olhos direito e esquerdo dos cães do mesmo grupo (p > 0,05). Valores médios e desvios padrão foram obtidos para profundidade da câmara anterior (D1), espessura da lente (D2), profundidade da câmara vítrea (D3) e comprimento axial do bulbo do olho (D4) nos três grupos. G1: D1 2,92mm (± 0,37), D2 7,03mm (± 0,61), D3 9,48mm (± 0,74) e D4 19,43mm (± 0,60). G2: D1 3,08mm (± 0,67), D2 7,02mm (± 0,87), D3 8,76mm (± 1,23) e D4 18,86mm (± 1,45). G3: D1 3,07mm (± 0,65), D2 7mm (± 0,81), D3 9,75mm (± 0,98) e D4 19,82mm (± 0,95). Para comparação dos valores médios de D1, D2, D3 e D4 entre os grupos, foi utilizado o teste de Tukey, com nível de significância de 5%. Na análise de D3, foi observada diferença (p < 0,05) na comparação entre G2 e G3. Na análise de D4, foi observada diferença (p < 0,05) na comparação entre G2 e G3 / The present study aimed to know the average values of the intraocular structures and compare among different skulls’ conformations in dogs using ocular ultrasonography with 20 MHz probe. They were selected 30 healthy adult dogs, body weight 10 kg, male or female, assisted at Governador Laudo Natel Veterinary Teaching Hospital - Faculdade de Ciências Agrárias e Veterinárias – UNESP – Campus of Jaboticabal. Animals were divided into three groups: G1 - 10 brachycephalic dogs, G2 – 10 mesocephalic dogs and G3 - 10 dolicocephalic dogs. The Student t test at 5% significance level was used to compare difference between right and left eyes of the dogs in the same group and no difference was found (p > 0.05). Mean and standard deviations were obtained for anterior chamber depth (D1), lens thickness (D2), vitreous chamber depth (D3) and axial length of the eye globe (D4) in the three groups. G1: D1 2.92mm (± 0.37), D2 7.03mm (± 0.61), D3 9.48mm (± 0.74) and D4 19.43mm (± 0.60). G2: D1 3.08mm (± 0.67), D2 7.02mm (± 0.87), D3 8.76mm (± 1.23) and D4 18.86mm (± 1.45). G3: D1 3.07mm (± 0.65), D2 7mm (± 0.81), D3 9.75mm (± 0.98) and D4 19.82mm (± 0.95). The Tukey test at 5% significance level was used to compare the average of D1, D2, D3 and D4 among groups. Differences between G2 and G3 were found (p <0.05) when comparing D3 and D4
65

Ecobiometria nos modos A e B em cães da raça cocker spaniel inglês, com e sem catarata

Silva, Miguel Ladino [UNESP] 26 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-26Bitstream added on 2014-06-13T19:09:50Z : No. of bitstreams: 1 silva_ml_me_jabo.pdf: 215535 bytes, checksum: cd0cb8025e24b157abddf88c5cead9f9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A pesquisa foi desenvolvida visando-se a se avaliarem alterações nas dimensões de estruturas do bulbo de olho de cães da raça cocker spaniel inglês, machos e fêmeas, com e sem catarata, à ultrasonografia transcorneal nos modos A e B. Dezesseis pacientes (n = 16, 32 olhos, 10 machos, 6 fêmeas) com catarata e idade superior a 8 anos e um grupo controle sem catarata (n =7, 14 olhos, 2 manchos, 5 fêmeas) foram avaliados. Realizou-se ultrasonografia transcorneal nos modos A e B com transdutor de 10 MHz. Os dados referentes à ecobiometria, foram avaliados estatisticamente ao teste ANOVA de via única e os resultados expressos em média e desvio padrão (±DP). A incidência de catarata entre gênero foi avaliada estatisticamente ao teste de Fisher’s. O comprimento axial do bulbo do olho dos pacientes com catarata e dos do grupo controle respectivamente, foi de 19.909 ± 1,103 mm; 19,958 ± 1,050mm. Para a câmara anterior, encontraram-se 3,041 ± 0,828 mm; 3,373 ± 1,040mm, respectivamente. Para o diâmetro lenticular foram de 6,817 ± 1,117 mm; 7,062 ± 0,477mm, respectivamente, e para o segmento posterior foram 10,056 ± 0,754mm; 9,523 ± 0,705mm. Não se encontraram diferenças significativas entre olhos com catarata e os controles, tampouco entre machos e fêmeas com e sem catarata. Tampouco foi encontrada diferença em quanto à incidência das cataratas entre ambos os sexos (P > 0.05). / The present study was conceived to evaluate A- and B-mode ultrasonographic changes in the thickness of various structures of the eyeball in male and female English Cocker Spaniel dogs with and without cataracts. Sixteen dogs with cataracts (36 eyes, 10 males, 6 females), and seven normal dogs (14 eyes, 2 males, 5 females) older than eight years were selected. A- and B-mode ultrasonography was performed with a 10 MHz transducer. Echobiometry values were evaluated statistically by one way ANOVA. Incidence of cataract among gender was assessed by Fisher’s excat test. Mean and standard deviations of various ocular structures for dogs with and without cataracts were, respectively, anterior chamber: 3.041 ± 0.828 mm, 3.373 ± 1.040 mm; lens: 6.817 ± 1.117 mm, 7.062 ± 0.477 mm; vitreous: 10.056 ± 0.754 mm, 9.523 ± 0.705 mm; and axial length: 19.909 ± 1.103 mm; 19.958 ± 1.050 mm. Ocular measurements between right and left eyes, males and females, as well as in eyes with and without cataract were not significantly different. Incidence between gender were not significantly (P > 0.05).
66

Ultrassonografia transcraniana em cães adultos hígidos: padronização da técnica, aspectos anatômicos e biométricos

Cintra, Thassila Caccia Feragi [UNESP] 01 April 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-01Bitstream added on 2014-06-13T20:11:27Z : No. of bitstreams: 1 cintra_tcf_me_jabo.pdf: 1118712 bytes, checksum: 9ed4c1a0250026e0fd2cbccd8b8c5e84 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Com este trabalho objetivou-se correlacionar a ultrassonografia transcraniana com a anatomia encefálica, confeccionar um atlas com cortes anatômicos do encéfalo, à similitude dos planos de varredura ultrassonográficos, identificando e mensurando nas imagens as estruturas encefálicas visibilizadas, para padronizar dimensões em cães mesaticéfalos. Foram utilizados 37 cães adultos, hígidos, sem raça definida, sendo 30 in vivo e sete cadáveres. Nos cadáveres, após varredura, as cabeças foram removidas e seccionadas em planos anatômicos à similitude dos planos ultrassonográficos. Nos animais in vivo a identificação e as mensurações das estruturas encefálicas foram comparadas entre si para avaliar a repetibilidade da varredura eletrônica. No encefálo foram realizados cortes ultrassonográficos em planos dorsais e dorsais oblíquos pela janelas temporal e occipital, sendo passível visibilizar regiões dos lobos frontal, temporal e occipital, ventrículos laterais, septo pelúcido, fissura longitudinal do cérebro, sulcos suprasilviano, marginal e coronal, cerebelo, tentório ósseo do cerebelo, vermes do cerebelo, e medula oblonga. As médias e os desvios padrão das estruturas encefálicas nos 30 cães in vivo não variaram (p>0,05) em função das janelas temporais e foram 0,277cm ± 0,030 e 0,281cm ± 0,024; 1,643cm ± 0,115; 0,161 ± 0,021 e 0,157 ± 0,016; 2,248 ± 0,166 e 2,368 ± 0,212, respectivamente para largura dos ventrículos laterais direito e esquerdo; manto encefálico; espessura dos sulcos marginal e coronal; diâmetros ventro-lateral e crânio-caudal da região cerebelar / The goals o this study were to correlate transcranial ultrasonography with brain anatomy, to make an atlas with anatomical cuts of the brain that were similar to the ultrasound plane images, to identify and to measure the brain structures visualized, in order to standardize their dimensions in mesaticephalic dogs. In this experiment, 37 adult, healthy mongrel dogs were used – 30 alive and 7 corpses. After the ultrasound procedure the head of the corpse was removed and cut in anatomical planes as the ultrasound plane images. In the live animals, the brain structures identification and measurements were compared to each other to assess the reprodutibility of the ultrasound procedure. Ultrasound scans in dorsal and dorsal oblique planes were performed in the brain through the temporal and occipital window, with visualization of the frontal, temporal and occipital lobe, lateral ventricles, septum pellucidum, the longitudinal fissure of the brain, suprasylvian, marginal and coronal sulcus, cerebellum, the osseous tentorium of the cerebellum, the vermis of the cerebellum and the medulla oblongata. The average and the standard deviation of the brain structures of the 30 live dogs did not vary (p>0,05) in both temporal window and were 0,277cm ± 0,030 e 0,281cm ± 0,024; 1,643cm ± 0,115; 0,161 ± 0,021 e 0,157 ± 0,016; 2,248 ± 0,166 e 2,368 ± 0,212, respectively for width of the right and left lateral ventricles and cerebral mantle, thickness of the marginal and coronal sulcus, and ventrolateral and canio-caudal cerebellar diameter
67

Relação do Color Doppler e Power Doppler com densidade micro vascular intra tumoral corada com o anticorpo CD34 no câncer de mama /

Komatsu, Moisés Yoshifumi. January 2004 (has links)
Orientador: José Ricardo P. Rodrigues / Resumo: O aumento progressivo nas últimas décadas na incidência do câncer de mama é um fato que assola a humanidade, entretanto, as taxas de mortalidade tendem ao decréscimo em virtude da detecção precoce através de métodos de rastreio não invasivos, e do conhecimento cada vez maior do comportamento biológico do tumor. A maior adesão aos meios de rastreamento existentes hoje, deve-se não apenas ao medo que o câncer provoca nas mulheres, mas também ao fato dos exames utilizados para este rastreio não serem invasivos. Infelizmente, ainda não existem métodos capazes de dar indícios do comportamento biológico do tumor de forma instantânea, sem que haja a necessidade de submeter as pacientes portadoras de tumores malignos da mama a procedimentos cirúrgicos. Desde o início da última década do século XX, tem-se estudado a angiogênese do tumor através da ultra-sonografia, utilizando-se dos recursos de Color Doppler e Power Doppler. Neste trabalho, realizado no Hospital Santa Marcelina de Itaquaquecetuba, em conjunto com a Disciplina de Mastologia da Faculdade de Medicina de Botucatu - UNESP, foram estudadas trinta e cinco pacientes com tumores malignos da mama, onde os parâmetros hemodinâmicos (Índice de Resistência, Índice de Pulsatibilidade e a Velocidade Máxima no Pico Sistólico) através do Color Doppler... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although a progressive increase in the incidence of breast cancer is a fact that plagues mankind, mortality rates tend to decrease given precocious detection using non-invasive tracking methods and an ever-growing knowledge of tumoral biological behaviour. The current large adhesion to tracking methods is explained not only by the fear cancer raises in women but also to the use of non-invasive exams. Unfortunately, there are no methods capable of giving instantaneous indication of tumoral biological behaviour without submitting patients with malignant tumors to surgical procedure. Since the early nineties and now at the dawn of the 21st Century, the angiogenesis of the tumor is being studied with the help of Color Doppler and Power Doppler ultrasonography. In this research - carried out at Santa Marcelina Hospital in Itaquaquecetuba in cooperation with the Department of Mastology of the Botucatu Medical School, São Paulo State University, thirty five patientes with mammary malignat tumors were... (Complete abstract click electronic access below) / Mestre
68

Definition of Anatomical Planes for Use in Transvaginal Sonography

Dodson, Melvin G., Deter, Russell L. 01 January 1990 (has links)
Planes frequently used to identify radiologic and abdominal ultrasono‐graphic images such as transverse, coronal, and sagittal are generally not anatomically correct when applied to transvaginal ultrasonographic planes and images. More appropriate terminology specific for the planes imaged during transvaginal ultra‐sonography, such as TRANS‐pelvic and AP‐pelvic planes, are suggested. A TRANS‐pelvic plane refers to a plane imaged when the sound beam is directed across or from side to side in the pelvis. An AP‐pelvic plane refers to an image obtained when the sound beam is directed anteriorly and posteriorly.
69

Impact of Ultrasonography on use of Biologics in Patients with Rheumatoid Arthritis

Atzinger, Christopher B. 22 May 2018 (has links)
No description available.
70

The Use of Ultrasonography in Differentiating Cellulitis and Fluctuant Odontogenic Swellings

Poweski, Lisa M. 29 August 2012 (has links)
No description available.

Page generated in 0.1783 seconds