• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 566
  • 154
  • 15
  • 14
  • 10
  • 10
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 830
  • 385
  • 223
  • 103
  • 98
  • 95
  • 75
  • 74
  • 70
  • 69
  • 69
  • 67
  • 64
  • 63
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Valores de referência para área de secção transversa do cordão e vasos umbilicais aferidos pela ultrassonografia em gestações gemelares dicoriônicas / Reference values for cross-sectional area of the umbilical cord and vessels measured by ultrasound in dichorionic twin pregnancies

Douglas Bandeira Fernandes 14 May 2014 (has links)
OBJETIVO: Determinar os valores de referência, e examinar a correlação da área de secção transversa do cordão umbilical, e de seus componentes, com a idade gestacional (IG), em gestações gemelares. Examinar a correlação da área de secção transversa do cordão umbilical com o peso fetal estimado (PFE). MATERIAIS E MÉTODOS: Estudo prospectivo longitudinal envolvendo gestações gemelares dicoriônicas, não complicadas. Medidas ultrassonográficas das áreas de secção transversa do cordão umbilical (ASTCU), da veia (AVU) e artérias umbilicais (AAU), e da geleia de Wharton (AGW) foram obtidas em plano adjacente, próximo ao abdômen fetal, a cada três semanas. A correlação entre os parâmetros avaliados e a idade gestacional foi investigada por meio de modelo de regressão polinomial hierárquica, levando-se em consideração a variância segundo a idade gestacional, entre medidas obtidas em fetos da mesma gestação e, entre diferentes gestações. Para cada parâmetro estudado, foram calculados os valores correspondentes aos percentis 5, 10, 50, 90 e 95, para cada semana gestacional. RESULTADOS: Foram realizadas 334 avaliações ultrassonográficas em 44 gestações gemelares, entre 18 e 33 semanas (média: 3,8 ± 0,7 exames/gestação; intervalo médio entre exames: 3,3 ± 0,9 semanas). Os valores log-transformados de todos os parâmetros avaliados apresentaram correlação significativa (p<0,001) com a idade gestacional: Log(ASTCU) = - 2,287498 + 0,149298 x IG - 0,002302 x IG2, desvio-padrão DP = 0,113, R2 = 0,65; Log (AVU) = - 2,721487 + 0,119853 x IG - 0,001507 x IG2, DP=0,165, R2 = 0,58; Log (AAU) = - 4,223546 + 0,195454 x IG - 0,003080 x IG2, DP=0,163, R2 = 0,57; Log (AGW) = - 2,511648 + 0,157737 x IG - 0,002564 x IG2, DP=0,123, R2 = 0,55. A área de secção transversa do cordão umbilical apresentou correlação significativa com o peso fetal estimado (Log (ASTCU) = -1,602447 + 0,554502 x Log (PFE), R2 = 0,65, p < 0,001). CONCLUSÃO: Em gestações gemelares dicoriônicas, a área de secção transversa do cordão umbilical, e de seus componentes, mostram correlação positiva e significativa com a idade gestacional. A área de secção transversa do cordão umbilical também correlaciona-se significativamente com o peso fetal estimado / OBJECTIVE: To determine reference values, and examine the correlation between the cross-sectional area of the umbilical cord, and its components, with gestational age (GA) in twin pregnancies. To examine the correlation between the cross-sectional area of the umbilical cord with the estimated fetal weight (EFW). MATERIALS AND METHODS: A prospective longitudinal study involving uncomplicated dichorionic twin pregnancies. Sonographic measurements of the cross-sectional areas of the umbilical cord (UCCSA), umbilical vein (UVA) and arteries (UAA) and Wharton\'s jelly (WGA) were obtained in a plane adjacent to the fetal abdomen, every three weeks. The correlation between these parameters and gestational age was examined with hierarchical polynomial regression analysis. This modeling took into account the variance according to gestational age, fetuses within the same pregnancy and changes across different pregnancies. For each parameter, 5th, 10th, 50th, 90th and 95th centiles were calculated for each gestational week. RESULTS: 334 ultrasound scans were performed in 44 twin pregnancies, between 18 and 33 weeks (mean: 3.8 ± 0.7 scans/pregnancy, mean interval between scans: 3.3 ± 0.9 weeks). All umbilical cord log-transformed values showed a significant correlation (p < 0.001) with gestational age: Log (UCCSA) = - 2.287498 + 0.149298 x GA - 0.002302 x IG2, SD = standard deviation 0.113, R2 = 0.65, Log (UVA) = - 2.721487 + 0.119853 x GA - 0.001507 x IG2, SD = 0.165, R2 = 0.58, Log (UAA) = - 4.223546 + IG x 0.195454 - 0.003080 x IG2, SD = 0.163, R2 = 0.57, Log (WGA) = - 2.511648 + 0.157737 x GA - 0.002564 x IG2 , SD = 0.123, R2 = 0.55. The cross-sectional area of the umbilical cord also correlated significantly with the estimated fetal weight (Log (UCCSA) = -1.602447 + 0.554502 x Log (EFW), R2 = 0.65, p < 0.001). CONCLUSION: In dichorionic twin pregnancies, the cross-sectional areas of the umbilical cord, and its components, show a positive and significant correlation with gestational age. The cross-sectional area of the umbilical cord also has correlates significantly with the estimated fetal weight
82

Real-time three-dimensional ultrasound in obstetric application. / CUHK electronic theses & dissertations collection

January 2010 (has links)
Conotruncal anomalies are the leading causes of cyanotic congenital heart disease. We attempted to use live xPlane imaging of ductal arch view and in-plane view of IVS to screen the fetal conotruncal anomalies in 200 fetuses. There were 152 normal cases, 25 conotruncal anomalies and 23 other types of fetal CHDs were involved in this study. The visualization rate of the normal ductal arch view and in-plane view of IVS with live xPlane imaging was 100% (152/152), 100% (152/152) in normal cases, 8% (2/25), 12% (3/25) in conotruncal anomalies and 69.7% (16/23), 73.9% (17/23) in non-conotruncal CHDs, respectively. The visualization rate of abnormal ductal arch and in-plane view in conotruncal anomalies was much higher than that in non-conotruncal anomalies (P&lt;0.001). Therefore, it may be a useful tool for the assessment and diagnosis of fetal conotruncal anomalies. / In conclusion, real-time 3DE is a novel and promising technique to perform the prenatal examination, both the fetal heart and other system. It represents the future of 3D ultrasound and will become a useful tool for prenatal screening and diagnosis. / This thesis summarized real-time 3D ultrasound in obstetric application. With the introduction of matrix transducer, 3D scanning the fetus in real time became available. / We attempted to use real-time 3D ultrasound in obstetrics outside the fetal heart. We evaluated the feasibility of using real-time 3D ultrasound to assist in obtaining a true midsagittal view in first trimester. Eight sonographers, including FMF-certified and non FMF-certified operators, were asked to perform ultrasound examinations on five patients and forty patients were examined in total. It showed that the deviation from true midsagittal view was reduced greatly with the guidance of live xPlane imaging. Real-time 3D ultrasound can improve the accuracy of acquisition of a defined sonographic plane, and reduce the difference in performance between operators who are formally certified or not. / We demonstrated a novel method to visualize the aortic and ductal arch with live xPlane imaging. The visualization rate is 100%. Ductal arch view can be visualized by placing the reference line through pulmonary artery and descending aorta and aortic arch view can be acquired by putting the reference line along the transverse view of aortic arch and descending aorta on the 3VT view with live xPlane imaging. Therefore, live xPlane imaging is an easy and feasible method for real-time imaging of the ductal and aortic arch. / We explored the feasibility to perform the fetal heart screening using real-time 3DE with live xPlane imaging. We developed and reported the methodology of acquiring and examining the screening planes of the fetal heart with live xPlane imaging. The procedure was simple and straight. When performing the fetal heart screening with live xPlane imaging, we just need display the apical four-chamber view and mid-sagittal view of fetal upper thorax and other thing could be done by moving the reference line. The overall detection of four cardiac screen planes can reach 100%. / We explored to evaluate the entire fetal IVS with both live xPlane imaging and live 3D imaging. We can successfully assess the entire IVS in most fetuses (153/154). We also compared the images acquired by real-time 3DE and STIC in this thesis. It showed that less motion artifact encounters with real-time 3DE and the image quality of real-time 3DE is similar to STIC volume acquired from the sagittal view (P>0.05) and superior to STIC volume from the four-chamber view (P&lt;0.05). Therefore, real-time 3DE can be used to display the lateral view of the fetal IVS, and potentially may be a useful tool for the assessment and diagnosis of fetal VSDs. / Xiong, Yi. / Adviser: Tzekin Lau. / Source: Dissertation Abstracts International, Volume: 73-02, Section: B, page: . / Thesis (Ph.D.)--Chinese University of Hong Kong, 2010. / Includes bibliographical references (leaves 116-138). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Electronic reproduction. [Ann Arbor, MI] : ProQuest Information and Learning, [201-] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
83

Parastomal hernia : investigation and treatment

Näsvall, Pia January 2015 (has links)
Background Parastomal hernia is a common stoma complication causing the patient considerable inconvenience. The patient becomes aware of a bulge around the stoma, but a bulge is not always a parastomal hernia and diagnostics must be performed to enable differential treatment. It is difficult to distinguish between a bulge and a hernia. Results based on clinical examination and computerised tomography (CT) in the supine position, have not been convincing. Three-dimensional intrastomal ultrasonography (3D US) is a novel technique shown to be promising in the assessment of stoma complaints. Two studies were performed to determine inter- and intra-observer reliability as well as the validity of 3D US as an alternative to CT when assessing stoma complaints. There are numerous options for the treatment of parastomal hernia, but none has been shown superior. In the recent decades the use of mesh in the repair of incisional and inguinal hernia has become routine. New materials must be evaluated as there are potential morbidity and even mortality risks with mesh repair. As recurrence of a parastomal hernia is an even greater challenge, the method of choice should have a low risk for recurrence. A prospective multicenter study was performed to evaluate safety and recurrence rate when using Parastomal Hernia Patch BARDTM (PHP), a mesh specially designed for parastomal hernia repair. A stoma has a profound impact on the patient´s daily life, both physical and psychological. A parastomal hernia with its associated risk for leakage and incarceration worsens the situation. Patient driven assessment of healthcare outcome is important if we are to improve medical care. A quality of life (QoL) survey was performed to assess the impact of parastomal bulging and hernia on the patient´s daily life. Methods Forty patients were investigated and the 3D US images were twice evaluated by two or three physicians to assess inter- and intra-observer reliability. Totally 20 patients with stoma complaints requiring surgery were examined with CT and 3D US prior to surgery. The findings were compared with the intraoperative findings – regarded as the true outcome. Fifty patients with parastomal hernia requiring surgery were enrolled from three hospitals. Patients were followed up one month and one year after repair using PHP. Patients still alive in 2008 who had been operated between1996 and 2004 for rectal cancer in Uppsala/Örebro-, Stockholm/Gotland-, and Northern Regions (986 patients) and registered in the Swedish Rectal Cancer Registry (SRCR) were invited to fill in four QoL questionnaires. Results Inter-observer agreement using 3D US reached 80% for the last 10 patients examined, with a kappa value of 0.70. Intra-observer agreement for two examiners was 80% and 95%. The learning curve levelled out at 30 patients. Both CT and 3D US showed high sensitivity and specificity when compared with intraoperative findings. After surgery for parastomal hernia with a PHP, the complication rate at one month was 30% and recurrence rate at one year was 22%. Twelve patients were reoperated within one year. In the QoL study, 31.5% of the patients with a stoma reported a bulging or a hernia. 11.7% had been operated for parastomal hernia. A hernia or a bulge gave rise to significantly more pain and impaired stoma function. Overall QoL was inferior in patients with a permanent stoma compared to a group without a stoma.
84

Avaliação da traqueostomia percutânea guiada por ultrassonografia quando comparada à  traqueostomia percutânea guiada por broncoscopia / Ultrasound-guided percutaneous dilational tracheostomy compared to bronchoscopy-guided percutaneous dilational tracheostomy

Gobatto, Andre Luiz Nunes 08 December 2017 (has links)
A traqueostomia percutânea é um procedimento realizado rotineiramente na Unidade de Terapia Intensiva (UTI), guiada por broncoscopia. Recentemente, a ultrassonografia tem surgido como uma ferramenta potencialmente útil para assistir à traqueostomia percutânea e reduzir as complicações relacionadas ao procedimento. Um ensaio clínico randomizado, aberto, paralelo, de não inferioridade, foi conduzido comparando a traqueostomia percutânea guiada por ultrassonografia com a traqueostomia percutânea guiada por broncoscopia, em pacientes sob ventilação mecânica na UTI. O desfecho primário, a falência do procedimento, foi definido como um desfecho composto, incluindo (1) a conversão para traqueostomia cirúrgica, (2) o uso associado e não planejado da broncoscopia ou da ultrassonografia, ou (3) a ocorrência de uma complicação maior. Um total de 4.965 pacientes foram avaliados quanto a elegibilidade. Desses, 171 pacientes foram elegíveis e 118 foram submetidos ao procedimento, com 60 pacientes randomizados para o grupo ultrassonografia e 58 pacientes randomizados para o grupo broncoscopia. A falência do procedimento ocorreu em um (1,7%) paciente no grupo ultrassonografia e um (1,7%) paciente no grupo broncoscopia, sem diferença no risco absoluto entre os grupos (intervalo de confiança de 90%, -5,57 a 5,85), na análise \"conforme tratados\", não incluindo a margem de não inferioridade pré-especificada de 6%. Nenhum outro paciente apresentou uma complicação maior em ambos os grupos. As complicações menores relacionadas ao procedimento ocorreram em 20 (33,3%) pacientes no grupo ultrassonografia e em 12 (20,7%) pacientes no grupo broncoscopia, (P = 0,122). A duração do procedimento foi de 11 [7-19] vs. 13 [8-20] minutos (P = 0,468), respectivamente, e os desfechos clínicos também não foram diferentes entre os grupos. Em conclusão, a traqueostomia percutânea guiada por ultrassonografia é eficiente, segura e associada com taxas de complicações semelhantes à traqueostomia percutânea guiada por broncoscopia, em pacientes sob ventilação mecânica na UTI / Percutaneous Dilational Tracheostomy (PDT) is routinely performed in the intensive care unit (ICU) with bronchoscopy guidance. Recently, ultrasound has emerged as a potentially useful tool in order to assist PDT and reduce procedure-related complications. An open-label, parallel, non-inferiority, randomized controlled trial was conducted comparing the ultrasound-guided PDT with the bronchoscopy-guided PDT in mechanically ventilated critically ill patients. The primary outcome was procedure failure, defined as a composite end-point of conversion to a surgical tracheostomy; unplanned associated use of bronchoscopy or ultrasound during PDT; or the occurrence of a major complication. A total of 4,965 patients were assessed for eligibility. Of these, 171 patients were eligible and 118 underwent the procedure, with 60 patients randomly assigned to the ultrasound group and 58 patients to the bronchoscopy group. Procedure failure occurred in one (1.7%) patient in the ultrasound group and one (1.7%) patient in the bronchoscopy group, with no absolute risk difference between the groups (90% confidence interval, -5.57 to 5.85), in the \'as treated\' analysis, not including the pre-specified margin of 6% for noninferiority. No other patient had any major complication in both of the groups. Procedure-related minor complications occurred in 20 (33.3%) patients in the ultrasound group and in 12 (20.7%) patients in the bronchoscopy group, (P=0.122). The median procedure length was 11 [7-19] vs. 13 [8-20] minutes (P=0.468), respectively, and the clinical outcomes were also not different between the groups. In conclusion, ultrasound-guided PDT is effective, safe and associated with similar complication rates and clinical outcomes compared with bronchoscopy-guided tracheostomy in mechanically ventilated critically ill patients
85

Utilização da ultra-sonografia em cães com suspeitas de neoplasias do sistema digestório (fígado, intestinos e pâncreas) / The use of ultrasonography in the diagnostic approach of dogs with suspected of digestive neoplasm (liver, intestines and pancreas)

Froes, Tilde Rodrigues 04 June 2004 (has links)
Os objetivos do presente trabalho foram avaliar a acurácia do exame ultra-sonográfico para indicar o órgão abdominal afetado pelo processo neoplásico, determinar as características ultra-sonográficas dos diferentes tipos neoplásicos que acometem o fígado, os intestinos e o pâncreas, bem como analisar a eficácia da ultra-sonografia bidimensional em apontar a malignidade desses processos neoplásicos. A amostra foi constituída por 114 cães com suspeita de processo neoplásico, e a observação compreendeu um período de 12 meses consecutivos. Em 88 desses animais, a presença de neoplasia abdominal foi confirmada. Em 84 (95,4%) cães, a origem da massa foi corretamente classificada, em 3 (3,5%) foi erroneamente classificada e em 1 (1,1%), a massa não foi identificada pelo exame sonográfico. Os tipos cito-histológicos diagnosticados no fígado foram: colangiocarcinoma 6(50%), carcinoma hepatocelular 3(25,1%), tumor de células mesenquimais?hemangiossarcoma 1(8,3%), linfoma de pequenas células 1(8,3%) e cistoadenoma de vias biliares 1(8,3%). No intestino foram identificados adenocarcinoma 2(25%), linfoma 2(25%), leiomiossarcoma 2(25%), tumor de células mesenquimais 1(12,5%) e adenoma de cólon 1(12,5%). No pâncreas foram diagnosticados: adenocarcinoma pancreático 3(75%) e insulinoma 1(25%). Com relação à diferenciação entre tumores hepáticos malignos e benignos pela ultra-sonografia convencional, 11 casos (100%) foram suspeitos de malignidade e confirmados com o padrão-ouro; contudo, parâmetros suspeitos para malignidade também foram observados em um caso de tumor benigno. Ao analisar a ultra-sonografia na suspeita de tumores nos segmentos intestinais para a diferenciação entre tumores e processo inflamatório, 8 (100%) casos suspeitos para processo neoplásico foram confirmados; todavia, parâmetros suspeitos para processos neoplásicos intestinais também foram observados em 3 casos de enterite inflamatória granulomatosa. Ao analisar a ultra-sonografia na suspeita de tumores pancreáticos exócrinos, foi possível identificar e localizar a massa em sua maioria, mas a diferenciação segura entre processo neoplásico e pancreatite crônica não foi possível. Conclui-se que: o exame sonográfico é um bom método de detecção da origem do processo neoplásico abdominal, e que embora não específicos, o achado sonográfico auxilia na determinação da malignidade do processo. / The purposes of the present study were to evaluate the diagnostic accuracy of ultrasonography in the assessment of abdominal organs due to neoplastic process, to determine the ultrasonographic findings of each tumor type found in the liver, intestines and pancreas, and thereby study the potential contribution of ultrasonography to distinguish benign from malignant lesions. One hundred and fourteen dogs with suspected neoplastic disease were enrolled in this prospective study during 12 consecutive months. 88 dogs were diagnosed as having abdominal neoplasm. In 84(95,4%) dogs the affected organ was correctedly identified, in 3(3,5%) dogs the affected organ was incorrectedly identified and in 1 dog the affected organ wasn?t identified. The tumors types in the liver were: cholangiocarcinoma 6(50%), hepatocellular carcinoma 3(25,1%), mesenchymal hepatic tumor ? hemangiosarcoma 1(8,3%), small cell lymphoma 1(8,3%) and bile duct cystadenoma 1(8,3%). Tumor types in the intestines were: adenocarcinoma 2(25%), lymphoma in alimentary tract 2(25%), leiomyosarcoma 2(25%), mesenchymal cell tumor 1 (12,5%) and colon adenoma 1 (12,5%). In the pancreas were: pancreatic adenocarcinoma 3(75%) and insulinoma 1(25%). Considering ultrasonographic findings alone we could predict malignant lesion in 11(100%) cases, and all cases had proven malignant liver neoplasm. However, one case of benign liver neoplasia was erroneuosly consireded as being malignant . Ultrasonographic findings alone were of important diagnostic value in differentiating intestinal neoplasia from enteritis. Eight (100%) dogs showing ultrasonographic signs of malignancy were confirmed as having malignant intestinal neoplasia, however, the same signs were seen in 3 cases of inflamatory granulomatous enteritis. Pancreatic masses were correctedly identified, but it was not possible to confidently differentiate between pancreatitis and pancreatic neoplasia. We conclude that use ultrasonography is of great value in determining the affected abdominal organ for neoplasic process, and that the sonography findings although not specific, may help in the assessment of malignancy.
86

Repercussões dos exercícios de treinamento dos músculos do assoalho pélvico sobre os parâmetros hemodinâmicos uteroplacentários e fetais / Repercussions of pelvic floor muscle training on uteroplacental and fetal hemodynamic parameters

Okido, Marcos Masaru 15 April 2011 (has links)
O assoalho pélvico é anatomicamente dividido em fáscia endopélvica, diafragma pélvico e diafragma urogenital e o músculo levantador do ânus é considerada a estrutura mais importante na manutenção da estática dos órgãos pélvicos. Durante a gravidez, altos níveis de progesterona e relaxina associadas às alterações anatômicas promovidas pelo crescimento uterino são fatores que contribuem para o aumento da prevalência de incontinência urinária durante a gravidez e o puerpério. O treinamento dos músculos do assoalho pélvico (TMAP) durante a gravidez tem sido tema de vários estudos que tentam comprovar a sua eficácia na prevenção e tratamento da incontinência urinária e nos resultados do trabalho de parto e do parto. Na literatura, encontram-se trabalhos que avaliaram as repercussões fetais associadas à realização de exercício físico aeróbico, porém não existem estudos que realizaram essa investigação com exercícios específicos do assoalho pélvico. O objetivo deste estudo foi, portanto, avaliar os efeitos do TMAP sobre os parâmetros doplervelocimétricos da hemodinâmica uteroplacentária e fetal. Realizou-se um estudo do tipo experimental, prospectivo, randomizado e controlado com gestantes de baixo risco gestacional. Um grupo foi submetido aos exercícios de TMAP através de sessões semanais durante 16 semanas (grupo exercício) e outro grupo não foi submetido aos exercícios (grupo controle). Os exames ultrassonográficos foram realizados com 28, 32 e 36 semanas sendo avaliados os índices de resistência (IR) e pulsatilidade (IP) das artérias uterinas maternas e artérias umbilical e cerebral média fetal antes e após os exercícios. Na análise estatística foi utilizado o modelo de regressão linear com efeitos mistos (efeitos aleatórios e fixos). Este procedimento foi realizado através do software SAS® 9.0, utilizando a PROC MIXED. Foram incluídas 26 gestantes no grupo exercício e 11 no grupo controle. A análise da artéria uterina mostrou diferença na comparação do estudo Doppler com redução significativa de IP e IR após o exercício na avaliação com 36 semanas. Com este resultado, é possível concluir que a execução de exercícios desse tipo de TMAP, durante a gestação, não altera IP e IR na artéria umbilical e cerebral média com 28, 32 e 36 semanas de gravidez e nas artérias uterinas com 28 e 32 semanas, porém ocorre redução com 36 semanas de gravidez. / The pelvic floor is anatomically divided into endopelvic fascia, pelvic diaphragm and urogenital diaphragm, and the levator ani muscle is considered to be the most important structure for the static maintenance of the pelvic organs. During pregnancy, the high levels of progesterone and relaxin, together with the anatomical changes promoted by uterine growth, are factors that contribute to the increased prevalence of urinary incontinence during pregnancy and the puerperium. Pelvic floor muscle training (PFMT) during pregnancy has been investigated in several studies that have attempted to prove its efficacy in the prevention and treatment of urinary incontinence and in the results of labor and delivery. Studies evaluating the fetal repercussions associated with aerobic physical exercise are available in the literature, but there are no studies that perform this investigation with specific exercises for the pelvic floor. Thus, the objective of the present study was to assess the effects of PFMT on the Doppler velocimetry and uteroplacental and fetal hemodynamic parameters. An experimental, prospective, randomized and controlled study was conducted on pregnant women of low gestational risk. One group (N = 26) performed PFMT exercises once a week for 16 weeks (exercise group) and the other (N = 11) did not perform exercises (control group). Ultrasound exams were performed at 20, 32 and 36 weeks for the evaluation of resistance index (RI) and pulsatility index (PI) of the maternal uterine arteries and of the fetal umbilical and middle cerebral arteries before and after exercise. A mixed effects linear regression model (random and fixed effects) was employed for statistical analysis using the PROC MIXED method of the SAS® 9.0 software. Analysis of the uterine artery showed a difference in the comparison of the Doppler study, with a significant reduction of PI and RI after exercise at the 36 week evaluation. With this result, it is possible to conclude that the execution of this type of PFMT exercises during pregnancy does not alter the PI or RI of the umbilical and middle cerebral arteries at 28, 32 and 36 weeks of pregnancy or of the uterine arteries at 28 and 32 weeks, although there was a reduction at 36 weeks of pregnancy.
87

Avaliação de escore corporal em equinos através da ultrassonografia / Evaluation of body condition score in horses by ultrasonography

Martins, Roberto Alexandre Díaz Toledo 15 December 2011 (has links)
Atualmente, a avaliação do treinamento e da nutrição dos cavalos de esporte, vem sendo amplamente estudada , no intuito de atingir o máximo desempenho dos cavalos de esporte nas competições. A composição corpórea muscular e de deposição de gordura, assim como em humanos, é um dos melhores indicativos deste desempenho. O escore de condição corporal (ECC) é um indicador subjetivo do estado corpóreo em equinos, baseado exclusivamente no depósito de gordura .A ultrassonografia tem demonstrado ser uma ferramenta de grande valor nesta avaliação.Com o objetivo de estudar a relação do escore corporal com medidas de espessura de gordura e músculos obtidas através da ultrassonografia em três raças distintas , utilizou-se 14 equinos Puro Sangue Inglês(PSI), 7 equinos Quarto de Milha(QM) e 10 equinos Puro Sangue Árabe(PSA) , com idade média de 3,5± 0,5 anos e peso médio de 471 quilos. Os animais foram avaliados por ultrassonografia em três regiões paralelas a coluna vertebral: espessura da gordura lombar(EGL), espessura do músculo glúteo(EMG) e espessura da gordura na cauda(EGC).As mensurações foram realizadas a cada 30 dias ,durante 60 dias. Os resultados mostraram um comportamento diferente entre as raças, porém a correlação do escore corporal com a medida de espessura de gordura na base da cauda(EGC),teve uma maior correlação, comparada com as outras variáveis ultrassonográficas. A avaliação ultrassonográfica mostrou-se uma ferramenta confiável e prática de avaliação de condição corpórea nas raças de cavalos de esporte. / Currently, the evaluation of training and nutrition for sport horses, has been widely studied in order to achieve maximum performance of sport horses in competitions. The body composition of muscle and fat deposition, as well as in humans, is one of the best indicators of performance. The body condition score (BCS) is a subjective indicator of body condition in horses, based exclusively on fat deposition. Ultrasonography has proved to be a valuable tool in the evaluation. In order to study the relationship score with measures of body fat and muscle thickness obtained by ultrasonography in three distinct races, we used 14 Thoroughbred horses (PSI), 7 Quarter Horses (QM) and 10 Purebred Arabian horses (PSA) with a mean age of 3.5 ± 0.5 years and average weight of 471 kg. Os animals were evaluated by ultrasonography in three regions parallel to the spine, back fat thickness (EGL ), thickness of gluteal muscle (EMG) and fat thickness in tail (EGC). the measurements were performed every 30 days for 60 days. The results showed a different behavior between the races, but the correlation of scores with a measure of body fat thickness at the head of the tail (EGC), had a higher correlation, compared with the other variables Ultrasonographic evaluation proved to be a reliable and practical tool for assessing body condition of horses in sport horses.
88

Aplicação do ultrassom para avaliação de cavidades intra-ósseas, em mandíbulas de porco / Application of ultrasound for evaluation of intraosseous cavities in pig jaw

Ferreira, Thásia Luiz Dias 23 March 2010 (has links)
O ultrassom é rotineiramente utilizado para avaliação de tecidos moles, contudo é um método que possui características importantes para avaliação não somente destes tecidos, mas dos ósseos também, além de possuir recursos diferenciais que auxiliariam muito no planejamento do tratamento e do prognóstico; embasados nessa premissa analisamos a possibilidade de avaliação de alterações intra-ósseas, por meio do ultrassom. A amostra foi constituída por cinco mandíbulas de porco, maceradas, e avaliadas nas regiões dos terceiros molares (tanto do lado direito quanto do esquerdo, totalizando 10 avaliações), por possuírem nessa região uma cripta óssea expressiva, o que simularia uma lesão intra-óssea. Para as avaliações ultrassonográficas dois grupos de três observadores foram formados, sendo um de CirurgiõesDentistas (Radiologistas) e outro de Médicos (Ultrassonografistas), os quais avaliaram, individualmente, a facilidade de visualização da imagem obtida por meio da ultrassonografia, bem como também o grau de translucidez do osso. Sendo que 46,6% das avaliações feitas pelos Cirurgiões-Dentistas foram ponderadas como de fácil visualização, 13,3% foram considerados de média dificuldade para avaliação, contra 23,3% que foram classificadas como de difícil localização, contudo 16,6% não foram possíveis de serem observadas. Os médicos classificaram como de fácil visualização 43,3% das ultrassonografias avaliadas, 23,3% como de média dificuldade, 20% de difícil observação e não conseguiram visualizar em 13,3% da amostra. Após avaliar os resultados encontrados e embasados na revisão da literatura foi possível concluir que: é possível se avaliar cavidades intraósseas por meio da ultrassonografia, contudo, para isso é necessário que a cortical óssea, por onde o feixe de ondas ultrassônicas vai penetrar, esteja adelgaçada; o US é um método imaginológico de fácil execução e interpretação, uma vez que os Cirurgiões- Dentistas que não tinham acesso, nem familiaridade, com este recurso imaginológico, conseguiram não só utilizá-lo, mas também compreender suas imagens, contudo em um grau discretamente menor em relação ao grupo formado por Médicos Ultrassonografistas, o que pode ser justificado por uma maior experiência por parte desses profissionais; mais estudos devem ser conduzido a fim de se explorar mais os benefícios e as vantagens que o US pode oferecer na área Odontológica. / Ultrasound (US) is routinely used for evaluation of soft tissues; however it is a method that has important features to evaluate not only these tissues, but also hard tissues that could help in the treatment planning and prognosis. This study analyzed the possibility of evaluation of intra-osseous changes, by means of US; grounded in this premise. The sample consisted of five macerated pig jaws, and the third molars areas (both the right and the left, totaling 10 ratings) were evaluated as these regions have a significant bone crypt, which simulate an intra-osseous lesion. For ultrasound images assessments two groups of three observers were trained, one of dentists (Radiology specialists) and other of physicians (US specialists), which evaluated individually, the visualization of the image obtained by US, and also the translucency degree of the bone. Dentists have been considered 46.6% of the assessments of easy viewing; 13.3% were considered of medium difficulty; 23.3% were classified as very difficult, although 16.6% were not found. Physicians considered 43.3% of images of easy viewing; 23.3% were considered of medium difficulty; 20% were classified as very difficult, although 13,3% were not found. Based on this results and the literature findings, it is possible to conclude that US is a useful tool for assessment of intraosseus cavities, but cortical bone should be thin so the sound waves can penetrate. US is an imaging method easy to perform and interpret, as the dentists, who had no access or familiarity with US, could interpret its images, at a slightly lower level than the US specialists, which can be explained by greater experience by these professionals. More studies should be conducted in order to explore the potential benefits and advantages of US utilization in Dentistry.
89

Avaliação do uso da ultrassonografia modo B para exploração através de tecido ósseo de costelas bovinas / Evaluation of the use of ultrasound B-mode exploration through bone beef ribs

Abreu, Marcos Petto Nunes de 30 July 2012 (has links)
O uso da ultrassonografia, para diagnóstico, como forma de exame complementar na área da Saúde é cotidiano e consagrado, principalmente no estudo e avaliação das doenças em tecidos moles. Com a consolidação e o desenvolvimento deste método, novos usos vem sendo descritos. Existem relatos científicos da possibilidade do uso do ultrassom para avaliação de lesões no interior do tecido ósseo. Frente a esta alternativa, o presente estudo avaliou o uso da ultrassonografia para exploração através de tecido ósseo, de diferentes espessuras, com a utilização de um modelo laboratorial em costelas bovinas, definindo a espessura óssea cortical que permite a passagem do ultrassom. Primeiramente realizamos um ensaio experimental para definir a melhor metodologia para o estudo. O modelo laboratorial usado era constituído por uma costela bovina, macerada, desgastada em diferentes espessuras. A amostra do estudo foi constituída em 180 leituras de ultrassom provenientes de 20 costelas bovinas maceradas; onde cada uma delas foi examinada em 9 áreas que se diferenciavam na espessura do remanescente ósseo; assim definidas 4,0mm, 3,0mm, 2,5mm, 2,0mm, 1,5mm, 1,0mm, 0,5mm, 0,2mm e sem desgaste. Para os exames de ultrassom foi utilizado o aparelho de ultrassom portátil Terason t3000 (Terason, divisão da Teratech Corporation, USA). Os exames foram realizados pela técnica da imersão, onde se mergulhava os espécimes e o transdutor do ultrassom em um recipiente com água. Para avaliar se havia ou não passagem da onda de ultrassom pelo tecido ósseo, em uma determinada espessura, era observada a formação de imagem de um objeto metálico posicionado atrás do osso. Conforme observado pela tabulação dos resultados ocorreu a passagem das ondas de ultrassom através do osso de espessuras 2,0mm, 1,5mm, 1,0mm, 0,5mm e 0,2mm diferentemente do ocorrido nas espessuras 4,0mm, 3,0mm, 2,5mm e sem desgaste. Houve diferença estatisticamente significante (P<0,001) entre as espessuras menores ou iguais a 2,0mm e as espessuras maiores ou iguais a 2,5mm, quanto a formação de imagem ultrassonográfica de um objeto metálico posicionado atrás do tecido ósseo. Concluímos que houve possibilidade de utilização do exame de ultrassom na avaliação através do tecido ósseo de espessuras menores ou iguais a 2,0mm. / The use of ultrasound as a complementary examination in health diagnoses is something usual and well established, mainly in the study and evaluation of diseases in soft tissue. As the consolidation and development of this method ocourred, new uses for it has been described. There are scientific reports with the possibility of the use of ultrasound for the evaluation of lesions within the bone tissue. Faced with this alternative, the aim of the present study was to evaluate the use of ultrasound for exploration through the bone tissue of different thicknesses, using a laboratory model of beef ribs, so thath would be defined the minimum required thicknesses of cortical bone for passage of the ultrasound. First we conducted an experimental trial to determine the best methodology for the study. The laboratory model used consisted of beef ribs prepared in different thicknesses. The study sample consisted of 180 ultrasound readings from 20 macerated beef ribs, each of which was examined in 9 different areas defined as, no wear, 4.0 mm, 3.0 mm, 2.5 mm, 2.0 mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm in thicknesses of the remaining bone. For ultrasound scanning was used a portable ultrasound device, Terason t3000 (Terason, a division of Teratech Corporation, USA). The examinations were performed by the technique of immersion, where the specimens and the ultrasound transductor were immersed in a water tank. To assess whether there was passage of ultrasound waves by the bone tissue in a certain thickness, it was observed the occurrence of a image formation from a metallic object that was positioned behind the bone. As noted by tabulating the results, there was passage of ultrasound waves through the bone thickness 2.0mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm different from those occurred in thickness of 4.0mm, 3.0mm, 2.5mm and no wear. There was significant difference (P<0.001) between the thicknesses less than or equal to 2.0 mm and thickness greater than or equal to 2.5 mm, in the ultrasound imaging of a metallic object positioned behind the bone. We conclude that there was possibility of using the ultrasound examination in the evaluation through the bone thickness less than or equal to 2.0mm.
90

Proposta de mapeamento da vascularização normal da face por meio da ultrassonografia modo B e Doppler / Mapping proposition of the normal vasculature of the face though ultrasound B-mode and Doppler

Tucunduva, Maria José Albuquerque Pereira de Sousa e 31 July 2012 (has links)
O estudo do aporte sanguíneo da face é importante em função da cirurgia como para as cirurgias que fazem uso de retalhos. O bom restabelecimento da área depende da perfusão obtida. Os métodos de aquisição de imagem que investigam a vascularização da face muitas vezes são caros e acrescentam risco à condição do paciente. A ultrassonografia é um método de imagem que não oferece risco ao paciente, sendo acessível e realizado em tempo real. A intensidade do fluxo sanguíneo de uma determinada estrutura pode ser medida pelo modo Doppler e alterações do padrão de normalidade indicam uma possível deficiência na nutrição dos tecidos compreendidos, podendo mesmo levar o clínico a prever futuras afecções. O objetivo neste estudo foi captar a vascularização normal da face, por meio da ultrassonografia modo B e Doppler de modo a se propor um mapeamento dos principais vasos arteriais. Foi possível, utilizando-se transdutores linear e endocavitário proceder-se ao estudo da vascularização da face. Foram obtidos dados referentes à vascularização da face que permitissem a análise da hemodinâmica dos tecidos. Foram estudados três vasos de diâmetro reduzido (0,60mm a. angular; 0,55mm a. palatina maior; 0,45mm a. infraorbital), sendo que nestes foi possível adquirir gráficos de onda de velocidade de fluxo e, consequentemente, obter-se a velocidade de pico sistólico (VPS) e o índice de resistividade (IR). / The study of the blood supply of the facial tissues is important due to oral and maxillofacial surgery as for operations that make use of flaps. The proper restoration of the perfusion is essential to the success of these procedures. The image methods that investigate the vasculature of the face are often costly and add risk to the patients condition. Ultrasound is an imaging method that offers no risk, is affordable and is performed in real time. The intensity of blood flow of a given structure can be measured by Doppler mode and changes in the normal range can indicate a deficiency in the nutrition of tissues end even influence the clinician to predict future conditions. The aim of this study was to access the normal vasculature of the face through ultrasound B-mode and Doppler in order to propose a mapping of the arterial vessels. It was possible, using the linear and endocavitary probes to study the vascularity of the face. Data was obtained allowing the analysis of the tissue hemodynamics. It was possible to access three arteries of small diameter (0,60mm angular artery; 0,55mm greater palatine artery; 0,45mm infraorbital artery) and in all cases graphics of wave flow velocity. Therefore, the resistivity index (RI) and systolic peak velocity (SPV) could also be computed.

Page generated in 0.0663 seconds