Spelling suggestions: "subject:"humidade relativa doo Ar"" "subject:"humidade relativa ddo Ar""
1 |
Sensor de umidade capacitivo de óxido de alumínio anodizadoFaria, José Ângelo de 06 February 1995 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-07-26T16:45:45Z
No. of bitstreams: 1
texto completo.pdf: 10591056 bytes, checksum: 2fdf989c8c30ecf7cc07670697108251 (MD5) / Made available in DSpace on 2017-07-26T16:45:45Z (GMT). No. of bitstreams: 1
texto completo.pdf: 10591056 bytes, checksum: 2fdf989c8c30ecf7cc07670697108251 (MD5)
Previous issue date: 1995-02-06 / O sensor foi desenvolvido no Laboratório de Instrumentação do Departamento de Física da Universidade Federal de Viçosa. Basicamente, consiste de um capacitor plano em forma de disco, contendo uma placa de alumínio e outra de delgado filme de ouro, obtido por deposição de evaporação a vácuo. O dielétrico é o óxido de alumínio formado por eletrodeposição sobre a própria placa de alumínio e por anodização, cujo eletrólito foi uma solução de H2SO4 a 10%, com densidade de corrente elétrica controlada. Para a realização dos testes utilizou-se uma câmara de controle de umidade, efetuando-se sucessivas medidas da umidade relativa do ar no interior da câmara do valor correspondente à capacitância do sensor. Os testes mostraram que a capacitância do sensor varia, exponencialmente, com a umidade relativa do ar. Embora a maioria dos sensores tenha apresentado resistência elétrica muito elevada, não tendo sido possível medi-los, verificou-se, por meio de um dos sensores, que a resistência elétrica é outra grandeza do sensor que também varia com a umidade relativa do ar, sendo a relação entre resistência do sensor e umidade relativa do ar uma função logarítmica. Verificou-se também que, apesar de a capacitância variar exponencialmente com a umidade e de a resistência variar loogaritmicamente com a umidade, pode-se obter uma grandeza derivada da frequência, que, por meio de um circuito oscilador adequado, varie linearmente com a umidade relativa do ar. Isto vem facilitar a utilização desse sensor na construção de um higrômetro. Mediante resultados obtidos, concluiu-se que o sensor que apresentou melhor desempenho foi aquele obtido com anodização, cuja densidade de corrente foi de 0,10 mA/cm² e tempo de anodização de 30 minutos.
|
2 |
Microclima do cerrado: características higrotérmicas em Jataí e Caçu (GO) / Microclimate of closed: hygrothermal characteristics in Jataí and Caçu (GO)Rocha, José Ricardo Rodrigues 27 March 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-02-04T14:20:25Z
No. of bitstreams: 2
Dissertação - José Ricardo Rodrigues Rocha - 2015.pdf: 9032071 bytes, checksum: f7c5b727e8a6360824bc8a509326ab74 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-11T11:36:32Z (GMT) No. of bitstreams: 2
Dissertação - José Ricardo Rodrigues Rocha - 2015.pdf: 9032071 bytes, checksum: f7c5b727e8a6360824bc8a509326ab74 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-11T11:36:32Z (GMT). No. of bitstreams: 2
Dissertação - José Ricardo Rodrigues Rocha - 2015.pdf: 9032071 bytes, checksum: f7c5b727e8a6360824bc8a509326ab74 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-03-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The man has caused changes in the middle through the transformations, occupation and mode-tion of space, which generates the urban climate. Thus, urban studies are neces-sary is because the sums of these changes cause a hydrothermal discomfort and the dif- ferentiation of heat in the urban network, as shown in many studies. Thus, the study of obje-tive was to determine the variation of temperature and relative humidity (maximum and mí-nima) in two small cities in the Brazilian cerrado, Jataí and Caçu (GO). Thus pro-cured to identify the relationships between the physical aspects of the environment (hipsometria, exhibition sheds and land use) with vari-ations in climate issues, in fixed collection points in cities. Both cities are in the middle region South Goiás, Jataí in the micro region of the Southwest of Goias and Caçu in micro-Quirino-polis. It had as methodological basis the theory of urban climate proposed by Monteiro (1976) and Monteiro e Sezarino (1990), abor-giving the thermodynamic subsystem. To collect tempe-rature data and relati-va humidity were used termohigrômetros (HT-4000 and HT-500 model) distributed at 5 points in Caçu and 09 in Jataí, in which were collected every 30 minutes. For producing the maps as hipsometria, exposure of slopes, land use were used GIS Arcgis 10.1. It was found that the absolute maximum operating temperature (44.6 ° C) was recorded in P3 in Caçu at 14h39m, and Jataí showed 43.1°C in P1, at 13h25m, where land use influenced the values between the collection points, and the elevation for the difference between the ci-ties (range of 1.5°C). The lowest values of minimum temperatures also occurred in August, on 28 and 29, rises the performance of a stationary front, where Jataí was 4.9 ° C in P6, with very low rate of construction (1.1%) and high rate of vegetation (81.5%), and is located in valley bottom. In Caçu was recorded 6.4 ° C in P3, this building has a low rate, average grazing rate (11.5%) and vacant land with soil exposure (34.6%). The maximum relative humidity of air occurred in November 2013, and ranged 100-81% between cities, on 5, 8:26 in the performance of the SACZ and ZCOU. The minimum relative humidity values of the air occurred in August, on days 02, 03, 04, 05 09, 18, 28, 29 and 02 days in September, 09, 11 and 13, where the values varied 6-52 % between 13:00 the 17h00mm. From our analysis, we consider that there was influence of urban structure and the physical aspects of hygrothermal behavior between cities. This is because the local densely built and devoid of vegetation showed higher temperatures and lower humidity of the air, while the places with the highest afforestation rate and smaller buildings had lower rates of temperature and relative humidity of the larger air. / O homem vem provocando alterações no meio através das transformações, ocupação e mode-lação do espaço, o qual gera o clima urbano. Desta forma, os estudos urbanos fazem-se neces-sários, pois as somas destas transformações acarretam um desconforto hidrotérmico e a dife-renciação de calor na malha urbana, como já evidenciado em muitos estudos. Com isso, o ob-jetivo do estudo foi verificar a variação da temperatura e umidade relativa do ar (máxima e mínima) em duas cidades de pequeno porte do cerrado brasileiro, Jataí e Caçu (GO). Assim procurou-se identificar as relações entre os aspectos físicos do ambiente (hipsometria, exposi-ção de vertentes e uso do solo) com a variação dos aspectos climáticos, em pontos de coleta fixos nas cidades. Ambas as cidades situam-se na mesorregião Sul Goiano, Jataí na microrre-gião do Sudoeste de Goiás e Caçu na microrregião de Quirinópolis. Teve-se como base meto-dológica a teoria do clima urbano proposta por Monteiro (1976) e de Monteiro e Sezarino (1990), abordando o subsistema termodinâmico. Para a coleta dos dados de temperatura e umi-dade relativa do ar foram utilizados termohigrômetros (modelo HT-4000 e HT-500) distribuí-dos em 5 pontos em Caçu e 09 em Jataí, em que foram coletados a cada 30 minutos. Para a confecção dos mapas como: hipsometria, exposição das vertentes, uso da terra foram utilizados SIG Arcgis 10.1. Constatou-se que o valor máximo absoluto de temperatura (44,6°C) foi regis-trado no P3, em Caçu, às 14h39m, e Jataí apresentou 43,1°C no P1, às 13h25m, em que o uso do solo influenciou os valores entre os pontos de coleta, e a altitude para a diferença entre as cidades (amplitude de 1,5°C). Os menores valores de temperaturas mínimas também ocorreram em agosto, nos dias 28 e 29, sobe a atuação de uma frente estacionária, em que Jataí teve 4,9°C no P6, com muito baixa taxa de construção (1,1%) e alta taxa de vegetação (81,5%), além de ser localizado em fundo de vale. Em Caçu foi registrado 6,4°C, no P3, este possui baixa taxa de construção, média taxa de pastagem (11,5%) e terrenos vagos com exposição do solo (34,6%). A umidade relativa do ar máxima ocorreu em novembro de 2013, sendo que oscilou de 100 a 81% entre as cidades, nos dias 5, 8 e 26 sob a atuação das ZCAS e ZCOU. Os valores mínimos de umidade relativa do ar ocorreram em agosto, nos dias 02, 03, 04, 05 09, 18, 28 e 29 e em setembro nos dias 02, 09, 11 e 13, em que os valores oscilaram de 6 a 52%, entre 13h00m as 17h00mm. A partir das análises, consideramos que houve influência da estrutura urbana e os aspectos físicos no comportamento higrotérmico entre as cidades. Isso devido os locais densamente construído e desprovidos de vegetação apresentaram maiores temperaturas e menores umidades relativa do ar, enquanto que, os locais com maior taxa de arborização e menores taxas de construções tiveram temperatura menores e umidade relativa do ar maiores.
|
3 |
Relação clima e vegetação na área das bacias das usinas hidrelétricas de Barra dos Coqueiros e Caçu-GO / Climate and vegetation in area of hydropower plants of Barra dos Coqueiros and Caçu-GOLima, Andreia Medeiros de 14 March 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-09-23T16:55:23Z
No. of bitstreams: 2
Dissertação -Andreia Medeiros de Lima.pdf: 5430810 bytes, checksum: 357ae214fb5b84c650b1d337efdb073c (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-09-23T18:30:49Z (GMT) No. of bitstreams: 2
Dissertação -Andreia Medeiros de Lima.pdf: 5430810 bytes, checksum: 357ae214fb5b84c650b1d337efdb073c (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-09-23T18:30:49Z (GMT). No. of bitstreams: 2
Dissertação -Andreia Medeiros de Lima.pdf: 5430810 bytes, checksum: 357ae214fb5b84c650b1d337efdb073c (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2013-03-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective of the research was to analyze the rainfall on a the regional scale and compare
the temperature, air relative humidity and rain at local scale at points outside of
semideciduous seasonal forests (FES) and inside the FES, on the area of Barra dos Coqueiros
and Caçu hydropower plants (UHEs), in the lower course of the Rio Claro river e, in the cities
of Cachoeira Alta and Caçu, in the state of Goiás. The rainfall data were obtained from four
rainfall stations of the National Water Agency (ANA), (Cachoeira Alta, Itarumã, Quirinópolis
and Pombal) between 1977-2011 and experiment points out of semideciduous seasonal forests
(FES), with measurement of temperature and relative humidity and rainfall and inside the FES
with temperature and relative humidity of September 2011 to September 2012.The
methodological procedures were performed at regional, local and microclimate, with
calculation of standard years, statistical calculations, analysis of land use, exposure of the
slopes and comparison of climatic elements between points outside and inside the FES,
starting from a point reference. On a regional scale, in 35 years of averages of the four
seasons, we identified that 66% were standard years rainy, tending to rainy and habitual; the
spatial variability of rainfall shows higher concentration northwest and southwest basins and
climate trends indicated a trends of increase in stations and Cachoeira Alta Pombal and
decrease in Itarumã and Quirinópolis. On a local scale, in relation to land use, the total area of
965 km2 of the two basins, it was found that the greatest change occurred by increasing the
area occupied by water in 2009 was 0.6% and in 2011 becomes occupy 7.4%, which
represented an increase of 1200%, with loss of native vegetation and habitat. Regarding
climatic elements, temperature and relative humidity, on the reference point outside the FES
(P1) differences occurred in the absolute maximum temperature of 10.6 °C and the absolute
minimum of 7.8 °C, relative humidity was maximum absolute differences less than 1% and
the minimum absolute difference of 8%, relative to rainfall, the largest difference was 927
mm. At the point of reference within the FES (P15), the largest difference in maximum air
temperature was 10.5 °C and minimum 2.4 °C, the relative humidity was 3% absolute
maximum and minimum of 8%. In microclimatic scale, points out the FES, mainly focused on
the areas: north, east, west, northwest and southwest, which receive greater insolation showed
higher maximum temperatures between 52.7 to 46.9 °C, while the points located within the
FES, independent of the exposure of the strands had the absolute maximum temperature
between 36.7 to 47.2 ° C and absolute minimum between 3.8 and 6.5 °C. Therefore, the points
inside the FES showed dampening effect on the microclimate, and the absolute maximum
temperatures and temperature were lower and the minimum absolute and relative humidity
were high. / O objetivo da pesquisa foi analisar as chuvas em escala regional e comparar a temperatura, a
umidade relativa do ar e a chuva em escala local em pontos fora das Florestas Estacionais
Semideciduais (FES) e no interior das FES, na área das bacias das Usinas Hidrelétricas
(UHEs) de Barra dos Coqueiros e Caçu, no baixo curso do rio Claro, nos municípios de
Cachoeira Alta e Caçu no Estado de Goiás. Os dados de chuva foram obtidos de quatro
estações pluviométricas da Agência Nacional das Águas (ANA), (Cachoeira Alta, Itarumã,
Quirinópolis e Pombal) entre 1977 a 2011 e do experimento em pontos fora das Florestas
Estacionais Semideciduais (FES), com mensuração de temperatura e umidade relativa do ar e
chuvas e no interior das FES com temperatura e umidade relativa do ar de setembro de 2011 a
setembro de 2012. Os procedimentos metodológicos foram realizados nas escalas regional,
local e microclimática, com cálculo dos anos padrão, cálculos estatísticos, análise do uso da
terra, exposição das vertentes e comparação dos elementos climáticos entre os pontos fora e
interior das FES, partindo de um ponto de referência. Na escala regional, em 35 anos das
médias das quatro estações, identificaram-se que 66% foram anos padrão chuvosos, tendentes
a chuvosos e habituais; a variabilidade espacial das chuvas apresentou maior concentração a
noroeste e sudoeste das bacias e a tendência climática indicou tendência de acréscimo nas
estações de Cachoeira Alta e Pombal e decréscimo em Itarumã e Quirinópolis. Na escala
local, em relação ao uso do solo, da área total de 965 km2 das duas bacias, verificou-se que a
maior mudança ocorreu pelo aumento da área ocupada por água, em 2009 era de 0,6% e em
2011 passa a ocupar 7,4%, o que representou um aumento de 1200%, com perda de vegetação
nativa e habitat. Em relação a temperatura e umidade relativa do ar, no ponto de referência
fora da FES (P1) ocorreram diferenças na temperatura máxima absoluta de 10,6 °C e na
mínima absoluta de 7,8 °C; a umidade relativa máxima absoluta teve diferenças menores de
1% e na mínima absoluta diferenças de 8%; em relação às chuvas, a maior diferença foi de
927 mm. No ponto de referência no interior da FES (P15), a maior diferença na temperatura
máxima absoluta foi de 10,5 °C e a mínima 2,4 °C; a umidade relativa do ar máxima absoluta
foi 3% e a mínima de 8%. Na escala microclimática, os pontos fora das FES, principalmente
os voltados para as vertentes: norte, nordeste, oeste, noroeste e sudoeste, as quais recebem
maior insolação, apresentaram temperaturas máximas maiores entre 52,7 a 46,9 °C, enquanto
os pontos localizados no interior das FES, independente da exposição das vertentes, tiveram a
temperatura máxima absoluta entre 36,7 a 47,2 °C e a mínima absoluta entre 3,8 a 6,5 °C.
Assim, os pontos no interior das FES apresentaram efeito atenuador no microclima, sendo que
as temperaturas máximas absolutas e a amplitude térmica foram menores e as mínimas
absolutas e umidade relativa do ar foram elevadas.
|
4 |
Influência e correlação de variáveis meteorológicas com infarto agudo do miocárdio e diabetes mellitus.PEREIRA, Heronides dos Santos. 17 September 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-09-17T12:44:51Z
No. of bitstreams: 1
HERONIDES DOS SANTOS PEREIRA - TESE (PPGRN) 2012.pdf: 2978004 bytes, checksum: 87298fe36a826d21fc333216def2bb79 (MD5) / Made available in DSpace on 2018-09-17T12:44:51Z (GMT). No. of bitstreams: 1
HERONIDES DOS SANTOS PEREIRA - TESE (PPGRN) 2012.pdf: 2978004 bytes, checksum: 87298fe36a826d21fc333216def2bb79 (MD5)
Previous issue date: 2012-02-29 / As modificações no processo de urbanização das cidades e as mudanças que ocorrem com as variáveis meteorológicas sobre uma região contribuem para maior ocorrência de morbidades. Este trabalho teve o objetivo de estudar a influência e correlação de elementos meteorológicos nos casos de infarto agudo do miocárdio e diabetes mellitus em Campina Grande-PB nos anos de 2000 a 2009, visando entender o comportamento habitual e melhorar o controle sobre essas doenças, mediante as médias mensais de pressão atmosférica, temperatura média do ar, temperaturas máxima e mínima do ar, amplitude térmica, umidade relativa do ar, precipitação pluvial, velocidade do vento, insolação e evaporação. Utilizando-se de dados meteorológicos coletados na estação climatológica principal do Instituto Nacional de Meteorologia localizada na Empresa Brasileira de Pesquisa Agropecuária em Campina Grande (07º13’ Sul, 35º53’ Oeste). Altitude de 543 m e de informações sobre morbidades fornecidas pela Secretaria Municipal de Saúde da Prefeitura Municipal de Campina Grande-PB, este trabalho apresenta correlações que envolvem essas variáveis. Possíveis relações entre as variáveis dependentes e independentes, comprovando a influência do clima nas morbidades estudadas, foram demonstradas, neste estudo, utilizando-se Análise de Componentes Principais. Verificou-se que os elementos meteorológicos influenciam diretamente na incidência do infarto agudo do miocárdio e do diabetes mellitus e que os elementos que mais contribuíram para o aumento do número de casos de infarto agudo do miocárdio são a temperatura máxima do ar e a velocidade do vento. Os casos de diabetes mellitus teve melhor correlação com a precipitação e insolação, contudo, as temperaturas máximas e mínimas do ar também foram grandes responsáveis pelas referidas incidências. Foi verificado também que a insolação foi o principal elemento meteorológico na incidência das morbidades estudadas. / The changes in the cities urbanization process and the changes that occur with meteorological variables over a region contribute to higher incidence of morbidity. This work aimed to study the influence of meteorological elements and its correlation in cases of acute myocardial infarction and diabetes mellitus in Campina Grande-PB in the years 2000 to 2009, in order to understand the normal behavior and improve control of these diseases, by the monthly averages of atmospheric pressure, mean temperature, maximum and minimum temperatures of air, temperature range, relative humidity, rainfall, wind speed, solar radiation and evaporation. Using weather data collected at the main meteorological station of the National Institute of Meteorology located at the Brazilian Enterprise for Agricultural Research in Campina Grande (07 º 13 'South, 35 ° 53' W). Altitude 543 m and information about morbidity provided by the Municipal Health Department of Campina Grande-PB city, this study presents correlations involving these variables. Possible relationships between the dependent and independent variables, showing the influence of climate on the morbidities studied were demonstrated in this study using Principal Component Analysis. It was found that the weather elements directly influence the incidence of acute myocardial infarction and diabetes mellitus and the factors that contributed most to the increase in the number of cases of acute myocardial infarction are the maximum air temperature and wind speed. The cases of diabetes mellitus had better correlation with rainfall and sunshine, however, the maximum and minimum temperatures of air were also largely responsible for these incidents. It was also noticed that sunlight was the main weather element in the incidence of morbidities studied.
|
5 |
Análise da utilização de abrigos termo-higrométricos alternativos para pontos fixosValin Jr, Marcos de Oliveira 04 December 2015 (has links)
Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-05-18T16:24:10Z (GMT) No. of bitstreams: 1
DISS_2015_Marcos de Oliveira Valin Jr.pdf: 4219819 bytes, checksum: 4066786345f69d5358483ff03782449f (MD5) / Made available in DSpace on 2017-05-18T16:24:10Z (GMT). No. of bitstreams: 1
DISS_2015_Marcos de Oliveira Valin Jr.pdf: 4219819 bytes, checksum: 4066786345f69d5358483ff03782449f (MD5)
Previous issue date: 2015-12-04 / A padronização dos instrumentos de coleta de dados é fundamental para a qualidade dos estudos microclimáticos. Devido a limitações financeiras e necessidades especificas, muitos sensores, abrigos e sistemas alternativos aos padrões são desenvolvidos, baseados na experiência e criatividade dos pesquisadores. O objetivo geral deste trabalho é analisar o desempenho termo-higrométrico de abrigos micrometeorológicos de diferentes materiais alternativos em coletas de dados em pontos fixos. Para tanto, a metodologia consistiu em construir cinco tipos de abrigos, instalados em campo aberto para garantir o mesmo ambiente para o estudo, e avaliados quanto ao desempenho das variáveis termo-higrométricas, a facilidade de execução, os materiais e ferramentas utilizados, e os custos envolvidos. Os resultados apontaram que os abrigos do tipo vertical e o com pote de sorvete não se demonstram eficientes para a coleta de dados em pontos fixos, principalmente se utilizados durante o dia. Quanto aos demais tipos, com pratos plásticos, tubo de pvc na horizontal e casa de madeira, se mostraram alternativas viáveis quanto ao desempenho, cabendo analisar o local onde será utilizado para definir qual deles melhor se adapta, pois o horizontal depende de já conhecer o sentido da direção do vento, o de madeira do espaço disponível devido ao seu tamanho e peso e o de pratos depende da disponibilidade de pratos plásticos na cor branca. É possível também concluir que o desempenho termo-higrométrico não está associado apenas ao material empregado, mas também à sua forma. / The standardization of data collection instruments is critical to the quality of the microclimate studies. Due to financial constraints and specific needs, many sensors, shelters and alternative systems the standards are developed, based on experience and creativity of researchers. The aim of this study is to analyse the thermo-hygrometric performance Micrometeorological shelters of different alternative materials for data collection at fixed points.There fore, the methodology is to build five types of shelters, installed in the open to ensure the same environment for the study, and evaluated the performance of variable term-hygrometric, ease of execution, materials and tools used, and costs involved.. The results showed that the shelters of the vertical type and the ice cream pot does not demonstrate efficient to collect data at fixed points, especially if used during the day. As for the other types, with plastic plates, pvc pipe horizontally and wooden house, proved to be viable alternatives for performance, fitting analyse where will be used to determine which one best fits because the horizontal depends on already know sense of wind direction, the wood of the available space due to its size and weight and the dishes depends on the availability of plastic plates in white. It is possible to also conclude that the term-hygrometric performance is not only associated to the material used, but also to its form.
|
6 |
As interações espaciais e clima: o clima urbano de Iporá-GO / The spatial intaractions and climate: the urban climate of Iporá-GOAlves, Washington Silva 15 April 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-31T12:28:45Z
No. of bitstreams: 2
Dissertação - Washington Silva Alves - 2014.pdf: 6222035 bytes, checksum: e0cff4be2cc095e87ba7959924344c2a (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-31T12:30:57Z (GMT) No. of bitstreams: 2
Dissertação - Washington Silva Alves - 2014.pdf: 6222035 bytes, checksum: e0cff4be2cc095e87ba7959924344c2a (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-05-31T12:30:57Z (GMT). No. of bitstreams: 2
Dissertação - Washington Silva Alves - 2014.pdf: 6222035 bytes, checksum: e0cff4be2cc095e87ba7959924344c2a (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2014-04-15 / The city is located in the middle region Iporá the west Goiás, State of Goiás, 220 km from the capital, Goiânia. Its population, according to the IBGE (2010), of 31.274 inhabitants; of these, 28,545 live in the urban area, divided into 66 districts and 2,729 in rural areas. The objective of this research was to analyze the variation of temperature and relative humidity, maximum and absolute minimum, in a small town in the Brazilian cerrado, identifying the relationships with the physical aspects of the environment, urban morphology and function. The data of temperature and relative humidity were collected from October 2012 to October 2013, with termohigrômetros (HT-500 model) and automatic weather stations, over five points of the urban area and the rural area. The points of the urban area were differentiated as to building density, vegetation, and hypsometry, exposure of the slopes and the use and occupation of land. For the analysis of climatic factors - temperature and relative humidity - the local scale proposed by Andrade (2005), who defined it as a climate area with a characteristic combination of elements was used, which may correspond to a type of land use differentiated (neighborhood, city park), are the specific topography (valleys, hill, etc..). The methodology was based on the urban climate of Monteiro (1976) system, with emphasis on thermodynamic subsystem that addresses the behavior of temperature and relative humidity in urban environments. The ArcGIS 9.0, Spring 5.2 and Surfer 9.0 software for cartographic and spatial distribution of temperature and humidity values were used. It was found that the absolute maximum temperature (46,2°C) value was recorded in P2, in October 2012, at 14:30 hours and the absolute minimum occurred in P1 (8,3°C) in July 2013, the 07h . The absolute maximum relative humidity occurred in P2 (99%), in January 2013, and the minimum absolute humidity in P2 (8%), in September 2013. Was used linear regression to determine the correlation coefficient (r) and determination (R²), through electronic calculation sheets. The results showed that exposure of the slopes, vegetation density, construction, hypsometry, and patterns of use and occupation influenced the registry and variation the maximum and minimum absolute values of temperature and relative humidity in Iporá. / A cidade de Iporá está localizada na mesorregião do oeste goiano, no Estado de Goiás, a 220 km da capital, Goiânia. Possui uma população, segundo informações do IBGE (2010), de 31.274 habitantes; destes, 28.545 residem na área urbana, distribuídos em 66 bairros, e 2.729 na área rural. O objetivo desta pesquisa foi analisar a variação da temperatura e umidade relativa do ar, máximas e mínimas absolutas, em uma cidade de pequeno porte do cerrado brasileiro, identificando as relações com os aspectos físicos do ambiente, função e morfologia urbana. Os dados de temperatura e umidade relativa do ar foram coletados no período de outubro de 2012 a outubro de 2013, com termohigrômetros (modelo HT-500) e estações meteorológicas automáticas, distribuídos em cinco pontos da área urbana e um da área rural. Os pontos da área urbana foram diferenciados quanto à densidade de construção, vegetação, hipsometria, exposição das vertentes e uso e ocupação do solo. Para a análise dos fatores climáticos - temperatura e umidade relativa do ar – foi utilizada a escala local proposta por Andrade (2005), que a definiu como clima de uma área com uma combinação característica de elementos, podendo corresponder a um tipo de ocupação do solo diferenciado (bairro, parque urbano), sejam as condições topográficas específicas (vales, colina, etc.). A metodologia pautou-se no sistema clima urbano de Monteiro (1976), com ênfase no subsistema termodinâmico que aborda o comportamento da temperatura e umidade relativa do ar nos ambientes urbanos. Foram utilizados os softwares ArcGis 9.0, Spring 5.2 e o Surfer 9.0 para os levantamentos cartográficos e na espacialização dos valores de temperatura e umidade. Constatou-se que o valor máximo absoluto de temperatura (46,2°C) foi registrado no P2, em outubro de 2012, às 14h30m e o mínimo absoluto ocorreu no P1 (8,3°C), em julho de 2013, às 07h. O máximo absoluto de umidade relativa do ar ocorreu no P2 (99%), em janeiro de 2013, e o mínimo absoluto de umidade no P2 (8%), em setembro de 2013. Utilizou-se da regressão linear para determinar o coeficiente de correlação (r) e de determinação (R²), por meio de planilhas de cálculo eletrônico. Os resultados revelaram que a exposição das vertentes, a densidade de vegetação, construção, a hipsometria, e os padrões de uso e ocupação do solo influenciaram no registro e na variação dos valores máximos e mínimos absolutos da temperatura e umidade relativa do ar em Iporá.
|
7 |
Estudo microclimático do ambiente de cavernas, Parque Estadual Intervales, SP / Microclimate study of caves enviroment, Parque Estadual Intervales, SPRocha, Bárbara Nazaré 31 August 2010 (has links)
A proteção ambiental dos recursos geológicos é uma questão com crescente interesse. A exploração de cavernas é uma das formas de turismo associada a recursos geológicos mais difundida. Por isso, deve-se conhecer suas características ambientais, tais como os climáticas, para definir estratégias de gestão e conservação ambiental associadas a seu uso turístico. Assim, o objetivo geral da pesquisa é detectar as principais alterações microclimáticas ocorridas no ambiente cavernícola em decorrência das visitas turísticas no interior das grutas do PEI, SP. Como objetivos específicos, definiu-se: caracterizar o microclima do ambiente de caverna em condições naturais e elencar características físicas da cavidade que influenciem em seu microclima. A metodologia consistiu na coleta de dados de temperatura e umidade relativa do ar de nove cavidades com registradores autônomos. Também foram registrados os valores de CO2. A variação dos atributos do clima foi analisada em situação natural e na presença de visitantes. Os resultados mostram que o microclima das cavernas tende à estabilidade dos valores de temperatura do ar e apresentam umidade relativa do ar e concentração de gás carbônico elevada. Cavernas com rios caudalosos e claraboias não apresentam impacto em sua atmosfera decorrente do turismo, pois as trocas gasosas com o meio externo são facilitadas. Nas grutas secas e afóticas, com entradas e corredores estreitos, o microclima tende à estabilidade, estando mais sujeito a impactos, especialmente elevações na temperatura do ar. O uso de carbureteira também gera acréscimos significativos nas concentrações de gás carbônico. / The ambient protection of the geologic resources is a question with increasing interest. The caves exploration is one of the geological tourism forms more spread out. Therefore, the characteristics of its ambient must be known, such as the climatic ones, to define strategies of management and ambient conservation associates with its tourist use. Thus, the general objective of this research is to detect the main microclimatic alterations in the cave environment in result of the tourist visits in the interior of grottos of PEI, SP. As specific objective, it was purposed to characterize the cave microclimate in natural conditions and to detect the physics characteristics of the caves that influence in its microclimate. The methodology consisted in collect data of temperature and relative humidity of the air of nine caves with automatic sensors. Also the values of carbonic gas had been registered. The variation of the climatic attributes was analyzed in natural situation and in presence of visitors. The results show that the caves microclimate tends to have stability values of air temperature and present high values of air relative humidity and carbonic gas concentration. Caves with rivers of great volume and skylights do not present impact in its atmosphere, even in the presence or tourists, because the gaseous exchanges with the external way are facilitated. In dry and dark grottos, with narrow entrances and corridors, the microclimate tends to stability, being subject to impacts, especially rises in the air temperature.
|
8 |
ATIVIDADE FÍSICA NO CALOR: ANÁLISE DA VARIAÇÃO DO PERCENTUAL DE GORDURA EM ATLETAS DE FUTEBOL DURANTE UM CAMPEONATORamalho, Roberto Mendes 21 June 2012 (has links)
Made available in DSpace on 2016-08-10T10:53:32Z (GMT). No. of bitstreams: 1
ROBERTO MENDES RAMALHO.pdf: 8922799 bytes, checksum: 527c28b11b6605a54382f1d802a94a54 (MD5)
Previous issue date: 2012-06-21 / Soccer is a sport characterized by the alternation of short duration and intense
motor actions, indicating the importance of physical preparation for the game's
performance. The physical training is associated with the control of the variation of
fat percentage, which can affect the athlete's performance. Several studies
demonstrate the incompatibility between the competitive excellence and high
levels of subcutaneous fat. Another important point is the practice of soccer in hot
and humid environments, because is needed a systematic care with the liquids
intake, which should be observed like a strategy to minimize heat-related
problems. The general objective of this study were to determine the variations of
the fat percentage of soccer players in a certain team during a championship. Also
the specific objectives are: a) compare the fat percentage found in the different
positions of the players; b) verify if there are other studies about this subject and
compare the fat percentage; c) examine whether and climatic conditions such as
heat and high humidity can affect the range of the results during the tournament;
compared to other data collections and other published studies related of fat
percentage in different conditions of heat and humidity. Four data collection were
made to evaluate the fat percentage by Jackson and Pollock 7 skinfold protocol. It
was analyzed Twenty-five professional soccer players from Marabá s Eagle Team
(Brazil), who competed in the 2011 C Series Brazilian Soccer Championship. In
the average, participant athletes were 27.53 ± 4.96 years old, 1.76 ± 0.07 of height
and initial weight of 73.81 ± 8.35. Analyzing the data collection for months, there
was no significant statistical difference in body mass and body fat percentage
between assessments. A significant difference was detected only in body mass
and body fat percentage among goalies and wide midfielders during all researched
months. In September there was also a difference in body mass between
defenders and wide midfielders. Thus, this study observed that the weather
conditions had no significant influence in the variation in the fat percentage in this
studied group of soccer athletes. / O futebol é um desporto caracterizado pela alternância de ações motoras intensas
e de curta duração, evidenciando a importância da preparação física para o
desempenho do jogo. Aliado à preparação física está o controle da variável
percentual de gordura, variável esta que pode afetar no desempenho do atleta.
Vários estudos demonstram a incompatibilidade entre a excelência competitiva e
altos índices de adiposidade subcutânea. Outro ponto que deve ser observado é a
prática do futebol em ambientes considerados quentes e úmidos, pois cuidados
com a ingestão sistemática de líquidos devem ser observados com vistas a
minimizar problemas relacionados ao calor. Os objetivos deste estudo foram
verificar a variação do percentual de gordura de jogadores de futebol de uma
determinada equipe durante um campeonato; comparar o percentual de gordura
nas diferentes posições dos jogadores; verificar se existem outros estudos nesse
âmbito e comparar o percentual de gordura; analisar se existe influência das
condições climáticas de calor e umidade elevados, na variação do percentual de
gordura encontrados durante o campeonato, comparado a outras coletas de
dados e outros estudos existentes relacionados à percentual de gordura em
jogadores de futebol em diferentes condições de calor e umidade. Foram feitas
quatro coletas de dados para avaliar o percentual de gordura que foi determinado
através do protocolo de Jackson e Pollock (7 dobras).Foram avaliados vinte e
cinco jogadores de futebol profissional da equipe do Águia de Marabá que
disputaram o campeonato brasileiro da série C de 2011. Os atletas apresentaram
média de idade de 27,53 ± 4,96; média de estatura de 1,76 ± 0,07 e média de
massa corporal inicial de 73,81 ± 8,35. Analisando as quatro coletas de dados por
meses, não houve diferença estatisticamente significante de massa corporal e
percentual de gordura entre as avaliações. Detectou-se diferença significativa
apenas na massa corporal e percentual de gordura entre goleiros e laterais em
todos os meses avaliados e na massa corporal entre zagueiros e laterais na
coleta do mês de setembro. Dessa forma, observou-se nesse estudo que as
condições climáticas a que foram submetidos, não influenciou significativamente
na variação do percentual de gordura desse grupo de atletas.
|
9 |
Influência de lagos artificiais no clima local e no clima urbano: estudo de caso em Presidente Epitácio (SP) / Influence of artificial lakes in local climate and urban climate: a case study in Presidente Epitácio (SP)Souza, Marcos Barros de 02 September 2010 (has links)
Nas últimas décadas tem sido temática de estudos as alterações realizadas no meio ambiente urbano e as variabilidades climáticas que ocorrem a partir das intervenções, principalmente no que se refere à formação de lagos artificiais para construção de usinas hidrelétricas. As transformações antrópicas de um determinado espaço físico podem ocasionar variações nos atributos climáticos, como a umidade relativa do ar e a temperatura do ar, dentre outros. O objetivo geral desta pesquisa foi verificar as possíveis alterações no clima local e do clima urbano da cidade de Presidente Epitácio, localizada no extremo oeste do Estado de São Paulo, devido à formação do lago artificial para a construção da Usina Hidrelétrica Engenheiro Sérgio Motta (Porto Primavera), utilizando registros da temperatura do ar e da umidade relativa do ar em um transecto da margem do lago passando pela área urbana até o ambiente rural circunvizinho, analisando as variáveis temporal, espacial e horária em diferentes períodos do ano (primavera, verão, outono e inverno), bem como a análise dos desvios da temperatura do ar e da umidade relativa do ar, entre os postos localizados próximos ao lago, na área intra-urbana e na área rural. A área de estudo constitui o município de Presidente Epitácio (SP) e o lago artificial foi formado pelo represamento das áreas do rio Paraná, na divisa entre os Estados de São Paulo e de Mato Grosso do Sul. A região possui clima tropical com verão úmido e inverno seco, registrando temperaturas máximas de 40°C e mínimas de 10°C, tendo os meses chuvosos de novembro a março com pluviosidade média anual de 1.200mm a 1.400mm e umidade relativa do ar de cerca de 80%. Para a coleta de dados realizada entre setembro de 2008 e setembro de 2009, sendo trinta dias em cada estação (primavera, verão, outono e inverno), foram utilizados sensores digitais de temperatura do ar e de umidade relativa do ar da marca StowAway, instalados em sete postos. Na variação da temperatura do ar entre os postos da área intra-urbana, da área de influência do lago e da área rural foi possível verificar que nos horários de maior produção de energia, ou seja, durante o período diurno as diferenças das amplitudes diminuem e no período noturno aumentam, devido ao volume de energia produzida no período diurno e dissipação desta energia no período noturno. Na variação da umidade relativa do ar entre os postos da área intra-urbana, da área de influência do lago e da área rural verificou-se que as amplitudes são maiores durante o período noturno, sendo menores durante o período diurno, ou seja, as amplitudes higrométricas são menores na área de influência do lago e na área rural do que na área intra-urbana. Conclui-se que, apesar de não haver valores significativos entre os postos, a presença do lago não contribui para o aumento da temperatura do ar e da umidade relativa do ar, porém funciona como um maior equilíbrio térmico e higrométrico. / In the last decades it has been subject of studies the changes urban environment and the climate variability that occur from interventions, especially as regards the formation of artificial lakes for hydroelectric plants. The anthropogenic transformation of a given physical space can cause variations in climatic attributes such as relative humidity and air temperature, among others. The objective of this research was to investigate the possible changes in local weather and climate in the city of Presidente Epitácio, located in the extreme west of São Paulo, due to the formation of an artificial lake to build the hydroelectric plant Engenheiro Sérgio Motta (Porto Primavera), using records of air temperature and relative humidity in a transect from the shore through the urban area to the surrounding rural environment, analyzing the temporal, spatial and hourly variables at different times of year (spring, summer, autumn and winter), as well as analysis of the deviations of air temperature and relative humidity between stations located near the lake in the intra-urban and rural areas. The study area is the city of Presidente Epitácio (SP) and the artificial lake was formed by damming the areas of the Paraná river on the border between the states of São Paulo and Mato Grosso do Sul. The region has tropical climate with wet summer and dry winter, recording maximum temperatures of 40°C and minimum 10°C in the rainy months from November to March with average annual rainfall of 1,200mm to 1,400mm and relative humidity of about 80%. For data collection conducted between September 2008 and September 2009, with thirty days in each season (spring, summer, autumn and winter), digital sensors for air temperature and relative humidity of the StowAway brand were used and installed in seven stations. The variation of air temperature between the positions of intra-urban area, of near de lake area and of the rural area it was verified that at times of increased energy production. During daytime differences of amplitudes decrease and increase at night due to the volume of energy produced during the day and dissipation of energy at night. Regarding the variation of relative humidity between the positions of intra-urban area, of near the lake and the rural area it was found that the amplitudes are larger during the night, being low during daytime. The the amplitudes are smaller hygrometric in the influence area of the lake and the rural area than in intra-urban area. We conclude that, although no significant values among the sites, the presence of the lake does not contribute to the increase of air temperature and relative humidity, but contributes to a better thermal and hygrometric balance.
|
10 |
DESENVOLVIMENTO E VALIDAÇÃO DE SISTEMAS DE MONITORAMENTO DE BAIXO CUSTO DE TEMPERATURA E UMIDADE RELATIVA DO AR / DEVELOPMENT AND DOWN MONITORING SYSTEMS VALIDATION COST OF TEMPERATURE AND HUMIDITY ON AIRRêgo, Márlison de Sá 11 January 2016 (has links)
From the perspective of optimizing the planning, management and management of water resources in the national context the hydrometeorological monitoring systems have gone through the process of technological innovation. Increased monitoring of potential for reduced costs and improved quality of monitored data motivate this field of research. Starting from the importance of the variables of temperature and relative humidity among the variables monitored, this paper proposes the development of three hardware systems and software based on an open platform, which measure these values accurately from three sensors low cost, RHT01, RHT02 and RHT03 available in the market from the year 2005. These sensors are part of the advancement of sensor lines, newly created, polymer and semiconductor oxides. The technological base of each system is the microcontroller "arduino rev. 3 ", which he managed an electronic circuit capable of collecting and storing data from hydro-meteorological variables, in a flash memory device (sd card). Then, in order to check the reliability on the operation, each system was subjected to three data collection tests, at three different sites operating simultaneously with conventional systems used by the Micrometeorology Laboratory of UFSM (LMMET/UFSM). Local tests are situated in the municipality of Santa Maria, in the state of Rio Grande do Sul, Brazil. The microclimate conditions were different among trials due to location. The first test was performed on the terrace of the INPE-UFSM facilities, the second test in micrometeorology Laboratory of UFSM and the third in a rural area of central campus of UFSM, characterized by the pampa biome, which is located a network monitoring tower micro-sulfux. The collections occurred during the months from April to June, representing the final step of the fall season and the beginning of winter in 2015. The first trial lasted eleven days, the second and third Thirteen Eleven. The time discretization of the collections was a minute. With the data collected was carried out comparative analysis of inexpensive and conventional systems by graphic systems for analysis, descriptive statistics, and statistics such as Pearson correlation coefficients, ANOVA and Tukey test. With determination coefficient values (R2) higher than 0.90 in all tests and no significant difference between low-cost sensors and analyzed conventional systems, with only one exception, the results indicated the feasibility of using these sensors to generate Data medium temperature and relative humidity for a minimum time interval from generation 1 minute, 15 minutes, 30 minutes and 1 hour. The results also indicated the possibility of further quantitative research on the influence of the sensors under the measured data. / Na perspectiva de otimizar o planejamento, manejo e gestão dos recursos hídricos no contexto nacional os sistemas de monitoramento hidrometeorológico tem passado pelo processo de inovação tecnológica. O aumento do potencial de monitoramento pela diminuição dos custos e a melhora na qualidade dos dados monitorados motivam esse campo de pesquisa. Partindo-se da relevância das variáveis de temperatura e umidade relativa do ar dentre as variáveis monitoradas, o presente trabalho propõe o desenvolvimento de três sistemas de hardware e software baseados em uma plataforma livre, que meçam essas grandezas com precisão a partir de três sensores de baixo custo, RHT01, RHT02 e RHT03, disponíveis no mercado a partir do ano de 2005. Estes sensores fazem parte do avanço das linhas de sensores, recém-criadas, de polímeros e óxidos semicondutores. A base tecnológica de cada sistema foi o microcontrolador arduino rev. 3 , o qual gerenciou um circuito eletrônico capaz de coletar e armazenar dados das variáveis hidrometeorológicas, em um dispositivo de memória flash ( sd card ). Em seguida, com o objetivo de verificar a confiabilidade quanto ao funcionamento, cada sistema foi submetido a três testes de coleta de dados, em três locais diferentes operando em simultâneo com sistemas convencionais utilizados pelo Laboratório de Micrometeorologia da UFSM (LMMET/UFSM). Os locais dos testes estão situados no município de Santa Maria, no Estado do Rio Grande do Sul, Brasil. As condições de microclima entre os testes eram diferentes em virtude do local. O primeiro teste foi realizado no terraço das instalações do INPE-UFSM, o segundo teste no laboratório de micrometeorologia da UFSM e o terceiro em uma área rural do campus central da UFSM, caracterizada pelo bioma pampa, onde fica localizada uma torre de monitoramento da rede micro-sulfux. As coletas ocorreram durante os meses de abril a junho, correspondendo a etapa final da estação de outono e início do inverno no ano de 2015. O primeiro teste durou onze dias, o segundo treze e o terceiro onze. A discretização temporal das coletas foi de um minuto. Com os dados coletados realizou-se análise comparativa dos sistemas de baixo custo e os sistemas convencionais mediante a análise de gráficos, medidas descritivas, e de estatísticas tais como a correlação linear de Pearson, análise de variância e teste Tukey. Com valores de coeficiente de determinação (R2) superiores a 0,90 em todos os testes e não havendo diferença significativa entre os sensores de baixo custo analisados e o sistemas convencional, com apenas uma única exceção, os resultados indicaram a viabilidade do uso destes sensores para geração de dados médios de temperatura e umidade relativa do ar para intervalo de tempo mínimo de geração de 1 minuto, 15 minutos, 30 minutos e 1 hora. Os resultados também indicaram a possibilidade de pesquisas quantitativas posteriores sobre a influência do abrigo dos sensores nos dados mensurados.
|
Page generated in 0.117 seconds