• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 103
  • 2
  • Tagged with
  • 106
  • 66
  • 21
  • 13
  • 11
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeitos da dermotonia no processo de cicatrização da ferida após colecistectomia laparotômica / EFFECT OF DERMOTONY IN THE PROCESS OF SURGICAL WOUND CICATRIZATION AFTER LAPAROTOMY CHOLECISTECTOMY.

Machado, Andrea Vasconcelos 01 July 2011 (has links)
The surgical wound is a factor of great interest for health field professionals, due to the complexity of cicatricial process. Dermotony is a noninvasive painless technique applied in a continual or pulsed way in order to decongest tissues by stimulating dermalgical zones. However, there are few scientific works which relate to its technical use. This study has aimed at evaluate edema in abdominal area; verify cicatricial retraction; evaluate dermotony in post-operative pain; verify inflammatory process. It is an experimental study of a clinical randomized trial character, in which 20 female patients have been submitted to laparotomy cholecistectomy surgery in the University Hospital of the Federal University of Sergipe, from June to November, 2010. Patients have been randomly separated in group A (treatment) and group B (control). Edema, cicatricial retraction, pain and inflammatory process have been the researched variables. In between-group comparison, for all variables, the treatment has not differentiated them eventually. Although, within-group comparison has showed a reduction from 0,77 to 1,36% in cirtometry, 5,22% in perimetry, and concerning pain perception, its reduction has reached 82,98%, being more evident within 4th and 5th administration. Nevertheless, it has not been verified within-group differences in prostaglandin measurement. At the end of the study, it has been concluded that in between-group comparison, dermotony has not differentiated them, though in within-group correlation, the results have been satisfactory for all variables, except for prostaglandin dosage. / A ferida cirúrgica é um fator de grande interesse para os profissionais da saúde, devido à complexidade que é o processo cicatricial. A dermotonia é uma técnica indolor e não invasiva aplicada de forma contínua ou pulsada para descongestionar os tecidos estimulando as zonas dermálgicas. No entanto, existem poucos trabalhos científicos que relatem a utilização da técnica. Os objetivos deste estudo foram avaliar o edema na região abdominal; verificar a retração cicatricial; avaliar a aplicação da dermotonia na dor pós-operatória; verificar o processo inflamatório. Trata-se de um estudo experimental, de caráter ensaio clínico randomizado, em que 20 pacientes foram submetidas à cirurgia de colecistectomia laparotômica no Hospital Universitário, da Universidade Federal de Sergipe, no período de junho a novembro de 2010. As mesmas foram divididas aleatoriamente em grupo A (tratamento) e grupo B (controle). As variáveis pesquisadas foram edema, retração cicatricial, dor e processo inflamatório. Na comparação entre os grupos, para todas as variáveis, o tratamento não os diferenciou no final da pesquisa. Já comparação intragrupo mostrou que houve uma redução entre 0,77 e 1,36% na cirtometria, na perimetria a diminuição foi de 5,22%, enquanto na percepção dolorosa a redução atingiu 82,98%, sendo mais evidente entre a 4ª e 5ª aplicação. No entanto, nas medidas de prostaglandinas não foi verificada diferença intragrupos. No final do estudo pode-se concluir que na comparação intergrupos, a dermotonia não os diferenciou, porém na correlação intragrupos os resultados foram satisfatórios para todas as variáveis, exceto na dosagem de prostaglandinas.
22

Remoção de Pb e Bi em liga de níquel por refino a vácuo. / Removal of lead and bismuth in nickel alloy by vacuum refining.

Clayton Paspardelli 25 February 2011 (has links)
As origens dos elementos residuais (trace element) nas ligas à base de Ni provém basicamente de duas fontes: (1) minérios e (2) sucatas. O controle da concentração destes elementos residuais é muito importante, pois afetam as propriedades mecânicas dessas ligas. Alguns estudos mostram que os elementos Pb e Bi têm um sério impacto negativo nos resultados dos ensaios de fluência das ligas a base de Ni. A presença dessas impurezas causa o aumento da quantidade de cavidades nos contornos de grão que resultam em fracasso prematuro na vida útil desse material. Dessa forma, este trabalho tem como objetivo estudar a cinética da remoção de elementos residuais, tais como Pb e Bi da liga VAT32 através da aplicação de vácuo durante a elaboração da liga. Os resultados obtidos demonstraram que a taxa de remoção dos residuais Pb e Bi no refino a vácuo atingiram percentuais de 99,6% e 96,1% respectivamente. Fatores como volume do cadinho, elevação de temperatura, níveis de vácuo abaixo de 10-4 mbar, limpeza do sistema que compreende câmara e cadinho (residuais de corridas anteriores), contribuem significativamente para as taxas acima descritas. Por outro lado, quanto maior o volume de liga fundida, diminuição de temperatura, vácuo deficiente ou contaminação do sistema, a taxa de remoção de Pb e Bi são prejudicadas. / The origins of trace elements in Ni-based alloys come basically from two sources: (1) minerals and (2) scrap. Control of the concentration of trace elements is very important because they affect the mechanical properties of these alloys. Some studies show that the elements Pb and Bi have a serious negative impact on the results of creep tests of Ni based alloys. The presences of these impurities cause the increase of the number of cavities at grain boundaries that result in premature failure of this material. Thus, this work aims to study the kinetics of removal of trace elements such as Pb and Bi in alloy VAT32 by applying vacuum during the preparation of the alloy. The results showed that the rate of removal of residual Pb and Bi in the vacuum refining reached 99.6% and 96.1% respectively. Parameters such as the crucible volume, high temperature, vacuum levels below 10-4 mbar, cleaning of the system which comprises chamber and crucible (residual from previous races), contribute significantly to the rates described above. Moreover, the higher the volume of molten alloy, low temperature, vacuum system contamination and low vacuum pressure decrease, refining degree of Pb and Bi.
23

Remoção de Pb e Bi em liga de níquel por refino a vácuo. / Removal of lead and bismuth in nickel alloy by vacuum refining.

Paspardelli, Clayton 25 February 2011 (has links)
As origens dos elementos residuais (trace element) nas ligas à base de Ni provém basicamente de duas fontes: (1) minérios e (2) sucatas. O controle da concentração destes elementos residuais é muito importante, pois afetam as propriedades mecânicas dessas ligas. Alguns estudos mostram que os elementos Pb e Bi têm um sério impacto negativo nos resultados dos ensaios de fluência das ligas a base de Ni. A presença dessas impurezas causa o aumento da quantidade de cavidades nos contornos de grão que resultam em fracasso prematuro na vida útil desse material. Dessa forma, este trabalho tem como objetivo estudar a cinética da remoção de elementos residuais, tais como Pb e Bi da liga VAT32 através da aplicação de vácuo durante a elaboração da liga. Os resultados obtidos demonstraram que a taxa de remoção dos residuais Pb e Bi no refino a vácuo atingiram percentuais de 99,6% e 96,1% respectivamente. Fatores como volume do cadinho, elevação de temperatura, níveis de vácuo abaixo de 10-4 mbar, limpeza do sistema que compreende câmara e cadinho (residuais de corridas anteriores), contribuem significativamente para as taxas acima descritas. Por outro lado, quanto maior o volume de liga fundida, diminuição de temperatura, vácuo deficiente ou contaminação do sistema, a taxa de remoção de Pb e Bi são prejudicadas. / The origins of trace elements in Ni-based alloys come basically from two sources: (1) minerals and (2) scrap. Control of the concentration of trace elements is very important because they affect the mechanical properties of these alloys. Some studies show that the elements Pb and Bi have a serious negative impact on the results of creep tests of Ni based alloys. The presences of these impurities cause the increase of the number of cavities at grain boundaries that result in premature failure of this material. Thus, this work aims to study the kinetics of removal of trace elements such as Pb and Bi in alloy VAT32 by applying vacuum during the preparation of the alloy. The results showed that the rate of removal of residual Pb and Bi in the vacuum refining reached 99.6% and 96.1% respectively. Parameters such as the crucible volume, high temperature, vacuum levels below 10-4 mbar, cleaning of the system which comprises chamber and crucible (residual from previous races), contribute significantly to the rates described above. Moreover, the higher the volume of molten alloy, low temperature, vacuum system contamination and low vacuum pressure decrease, refining degree of Pb and Bi.
24

Caracterização microestrutural e mecânica da liga NiTi com EMF produzida em forno de indução a vácuo.

Galeno Côrtes Martins de Oliveira 21 October 2010 (has links)
Este trabalho consistiu da caracterização das propriedades mecânicas, temperaturas de transformação martensítica e aspectos microestruturais da liga Ti 50,67(%at) Ni com efeito de memória de forma previamente produzida via fusão em forno de indução a vácuo denominada VIM 51. Foram analisados três formatos de materiais : tiras de NiTi de 0,82 mm de espessura, chapas de 1,7 mm de espessura e fios de 3,5 mm de diâmetro. Verificou-se que o processo de conformação mecânica da liga VIM 51 foi perfeitamente viável. Análises de MEV/EDS mostraram e semi quantificaram a presença dos precipitados TiC, Ti2Ni e Ti3Ni4. Os ensaios de calorimetria diferencial de varredura mostram que os picos de transformação martensítica surgem em função do tempo de envelhecimento e da temperatura a que a liga é submetida. Amostras solubilizadas e envelhecidas a 450oC por 30 e 150 minutos apresentam dois picos de transformação no resfriamento e dois picos no aquecimento. Isto é atribuído a precipitação de Ti3Ni4 que ocorre preferencialmente nos contornos de grão, provocando heterogeneidade de composição no material. Os ensaios de tração mostraram que amostras simplesmente laminadas apresentam uma curva característica de material convencional enquanto as amostras solubilizadas, solubilizadas e envelhecidas apresentam platô característico de materiais que apresentam o efeito de memória de forma.Verificou-se que amostras envelhecidas a 350C e 600C apresentam comportamentos próximos das amostras simplesmente solubilizadas com valores de tensões de escoamento altos. Já as envelhecidas entre 400 e 500C apresentam baixos valores de tensão de escoamento, possivelmente devido a precipitação de Ti3Ni4, que em média deixa a matriz empobrecida em níquel aumentando, consequentemente, a temperatura de transformação martensítica.
25

Otimização das câmeras astronômicas do instrumento Brazilian Tunable Filter Imager. / Astronomical cameras optimization for the Brazilian Tunable Filter Imager instrument.

Andrade, Denis Furtado de 17 May 2016 (has links)
Este trabalho apresenta os resultados obtidos no processo de otimização realizado nas câmeras astronômicas do instrumento BTFI (Brazilan Tunable Filter Imager) instalado no telescópio SOAR, no Chile, para reduzir o ruído nos sinais. O instrumento BTFI opera com duas câmeras astronômicas de alto desempenho que utilizam detectores de imagens denominados EMCCDs. Esses detectores são sensores de imagem baseados em dispositivos de carga acoplada (CCDs) otimizados por um estágio integrado de multiplicação de elétrons por avalanche. Essa característica permite atingir ao mesmo tempo altas taxas de leitura (10 MHz) e níveis de ruído muito baixos (<1 elétron/pixel). Detectores CCD exigem temperaturas de operação da ordem de -100oC para operar com baixo ruído, o que demanda uma série de especificações técnicas quanto ao projeto da câmera. O trabalho aqui exposto fundamentou-se na otimização de aspectos mecânicos e eletrônicos de câmeras astronômicas com o intuito de se obter a melhor relação sinal-ruído, mostrando a importância do correto desenho mecânico (do ponto de vista térmico) e sua influência no comportamento eletrônico da câmera. São expostos os resultados obtidos com as duas câmeras em laboratório, os métodos e processos de caracterização utilizados, bem como as simulações térmicas e experimentos realizados em laboratório. Com as técnicas empregadas alcançou-se níveis de ruído total menores que 0,18 elétrons/pixel/segundo para exposições de 10 segundos. Os resultados atingidos foram observados nas duas câmeras do instrumento BTFI e foram validados em laboratório, onde demonstraram estabilidade durante 71 dias consecutivos. Por fim, é mostrada uma caracterização comparativa entre as duas câmeras quanto aos níveis de ruídos, ganho, estabilidade, eficiência quântica, linearidade e relação sinal-ruído. / This work presents results of the optimization performed in the astronomical cameras from the Brazilian Tunable Filter Imager (BTFI), instrument for the SOAR Telescope in Chile, in order to reduce the signals noise. The BTFI instrument has two highperformance cameras equipped with detectors named EMCCDs, which are image sensors based on charge-coupled devices (CCDs) optimized by an electron multiplication integrated stage. This feature enables to achieve high readout rates (10 MHz) and very low noise levels (<1 electron/pixel) at the same time. CCD detectors demand running temperatures of about -100,sup>oC for very low noise operation, which requires a series of technical specifications for the camera design. The work shown here is based in the optimization of the mechanical and electronic aspects for the astronomical cameras, in order to obtain the best signal to noise ratio, showing the importance of the correct mechanical design (from the thermal point of view) and its influence on the camera electronic behavior. The laboratory results obtained with the two cameras, the characterization procedures, as well as the thermal simulations and laboratory ratification experiments that allowed achieve the results presented are exposed. Using such techniques it was possible to achieve total noise levels lower than 0.18 electron/pixel/second for 10 seconds of exposure time. The results achieved were observed in both BTFI cameras and were validated in laboratory showing 71 consecutive days of stability. Finally it is shown a comparative characterization between both cameras in: noise and gain levels, stability, quantum efficiency, linearity and signal to noise ratio.
26

Estudo da eletrooxidação de monóxido de carbono em RuO2(110), e visualização morfológica e atômica de fases ricas em oxigênio na oxidação de Ru(0001) através da microscopia de varredura por tunelamento / Study of the electrooxidation of carbon monoxide on RuO2(110), and morphological and atomic visualization of oxygen-rich Ru(0001) surfaces by means of Scanning Tunneling Microscopy

Alves, Otavio Brandão 20 July 2007 (has links)
Nos últimos 30 anos o crescimento paralelo das Ciências de Superfície tradicionais, em ambiente de ultra-alto vácuo (UHV), com a Eletroquímica levou ao nascimento de um novo campo interdisciplinar: Física de Superfície e Eletroquímica. Técnicas de ambas as áreas dão informações complementares e assim, quando realizadas em conjunto podem fornecer muitas respostas em nível atômico, estrutural e eletrônico quando o eletrodo está em contato com a solução eletrolítica. A intenção primordial dessa Dissertação foi o estudo fundamental das fases ricas em oxigênio presentes na superfície de Ru(0001) através de caracterizações eletroquímicas e morfológicas utilizando um sistema que permitiu o acoplamento de uma célula eletroquímica miniatura de fluxo a câmaras de UHV. Inicialmente exibi-se a modificação e a construção de equipamentos necessários para a preparação do sistema binário Au-Pt(111) e do óxido monocristalino Ru2O(110). Imagens de STM em escala morfológica mostraram o crescimento anisotrópico do filme de RuO2(110) sobre um substrato monocristalino de Ru(0001). Resultados obtidos através da técnica de Voltametria Cíclica na eletrooxidação de CO em RuO2(110) corroboraram cálculos teóricos sobre a estrutura da superfície quando esta em ambiente úmido. Superfícies modelos baseadas em ouro, crescido epitaxialmente sobre um substrato de Pt(111), foram preparadas no sistema de UHV. Dados eletroquímicos foram correlacionados às composições superficiais destas, mostrando o efeito do substrato prevalecendo sobre o efeito eletrônico. / In the last 30 years the parallel growth of the traditional Surface Science, under UHV environment, and Electrochemistry gave rise to a new interdisciplinary field: Surface Science and Electrochemistry. Techniques from both sciences give complementary information. Thus, in tandem, they are able to elucidate many atomic, structural and electronic phenomena, of an electrode in contact with a solution. The main goal of this Dissertation was the fundamental study of the Oxygen-rich Ru(0001) surface through electrochemical and morphologic characterizations using a coupled system which allowed the attachment of a miniature flow cell to UVH-chambers. Initially it is shown the construction and modifications of required equipments for the preparation of the binary system Au-Pt(111) and single crystal RuO2(110) oxide. Attainable morphological STM images demonstrated the anisotropic growth of the RuO2(110) over a Ru(0001) substrate. Results of the electrooxidation of CO on RuO2(110), obtained by means of Cyclic Voltammetry, corroborated theoretical calculations concerning the oxide superficial structure in a humid environment. Model surfaces based on Au, epitaxialy grown on a Pt(111) substrate, were prepared under UHV conditions. Electrochemical data and superficial composition were correlated, confirming that the substrate effect overcomes electronic strain effects.
27

Construção de um acelerador de elétrons de 20KeV: aplicação ao estudo dos polímeros. / Development of a 20KeV electron gun for the study pf polymers.

Sandonato, Gilberto Marrega 05 August 1983 (has links)
Construiu-se um acelerador de elétrons de baixa energia (Máximo de 20 KeV). Como fonte de elétrons utilizou-se um canhão de elétrons de cinescópio preto e branco, ou seja, com um único emissor termiônico. A energia do feixe eletrônico pode ser continuamente variada desde 0 a 20 KeV. A corrente eletrônica pode ser variada desde um valor mínimo de 10-12A a 3&#956A, permanecendo constante no tempo uma vez fixado o seu valor. Através da focalização ou desfocalização da imagem do feixe de elétrons, é possível variar-se a área irradiada desde um diâmetro mínimo de 1 milímetro a um máximo de 6 cm. A pressão final atingida nas câmaras de vácuo foi da ordem de 10-7Torr. Durante o funcionamento do canhão de elétrons, o cátodo do mesmo é danificado devido ao bombardeamento de íons em sua superfície. Para examinarmos o grau de danificação causado por este bombardeamento iônico, basta focalizarmos e examinarmos a imagem de feixe eletrônico sobre uma tela luminescente. Deve-se ressaltar que todo o acelerador de elétrons foi construído a partir de materiais e componentes totalmente nacionais. O acelerador de elétrons foi aplicado para estudar efeitos de irradiação de elétrons em Teflon usando-se o método do Split Faraday Cup. Foram medidas correntes transitórias de carga e descarga e determinaram-se o alcance médio dos elétrons e o valor da condutividade induzida pela radiação. / We have constructed a low energy electron accelerator (maximum energy 20 KeV). A black and white kinescope electron gun, with a single thermionic emitter was used as an electron source. The energy of electron beam can be changed continuously from 0 to 20 KeV. The intensity of the current can be changed from a minimum of 10-12A to a maximum of 3&#956A, and can be maintained constant in time after its value has been fixed. The irradiated area can be changed from a diameter of 1 millimeter to a maximum of 6 centimeter, by focalizing or defocalizing the image of electron beam. The final pressure reached in vacuum chambers was 10-7Torr. During operation the surface of cathode of electron gun is damaged by ion bombardment. The degree of damage can be checked if the cathode image is focalized and examined on a luminescent screen. The accelerator was used to study electron irradiation effects in Teflon, employing the method of the Split Faraday Cup. Transient charging and discharging currents were measured. The average range of electrons of the electrons and induced conductivity were determined.
28

Efeito da utilização de película e de diferentes formas de acondicionamento na conservação pós-colheita e fritura de batatas minimamente processadas / Effect of edible coating and different forms of packaging on post-harvest storage and frying of minimally processed potatoes

Dias, Patrice Daniele Berbert 24 October 2011 (has links)
O objetivo do estudo foi avaliar o efeito da utilização de película de metilcelulose e das atmosferas de acondicionamento com ar atmosférico, vácuo e argônio sobre a conservação de batatas minimamente processadas (MP) e também sobre sua qualidade após fritura. Tubérculos foram selecionados, lavados, sanificados, cortados na forma de palitos e tratados com ácido cítrico. As batatas foram imersas em solução filmogênica contendo metilcelulose (1%) e sorbitol (0,75%) como plastificante, com posterior secagem, acondicionadas sob ar atmosférico, e modificada com argônio (20seg. e 230mmHg), além de vácuo (15seg. e 54mmHg). O produto MP armazenado a 8°C durante 12 dias foi avaliado em intervalos de 3 dias mediante análises microbiológicas, fisiológicas, físicoquímicas e físicas. A cada 3 dias as batatas MP foram também fritas e avaliadas quanto à perda de umidade, absorção de óleo, textura instrumental e avaliação sensorial. O acondicionamento sob ar atmosférico foi efetivo em reduzir a perda de massa das batatas MP. As embalagens sob vácuo foram mais efetivas para o produto MP sem película, pois mantiveram o pH, acidez titulável, teor de amido e de açúcares mais próximos do dia do início do experimento, como também mantiveram baixo o índice de escurecimento. O acondicionamento sob vácuo, entretanto, não seria indicado quando a finalidade fosse a fritura, pois foi o tratamento que apresentou maiores perdas de umidade e maior absorção de óleo. O acondicionamento sob atmosfera de argônio também foi mais efetivo nas batatas MP sem película, sendo fator determinante em reduzir os teores de CO2 no interior da embalagem, apresentou menor taxa respiratória, menor índice de escurecimento tanto antes como após a fritura, reduziu a perda de umidade durante a fritura, manteve mais a firmeza do produto frito e também minimizou a absorção de óleo a partir do 3° dia de armazename nto. A utilização de película foi efetiva em reduzir a respiração do produto MP até o 6° dia. Já no produto frito, foi fator determinante na retenção de umidade das batatas, como também na redução, ao longo do armazenamento, da absorção de óleo / The aim of this study was to evaluate the effect of methylcellulose as edible coating and packaging atmospheres with atmospheric air, vacuum and argon on the conservation of minimally processed (MP) potatoes as well as on their quality after frying. Tubers were selected, washed, sanitized, cut in the shape of sticks and treated with citric acid. Potatoes were immersed in a filmogenic solution of methylcellulose (1%) with sorbitol (0,75%) as a plasticizer, dehydrated, and then packaged under atmospheric air, and modified with argon (20seg. e 230mmHg), and vacuum (15seg. e 54mmHg). Stored MP product at 8°C for 12 days was assessed at intervals of 3 days by microbiological, physiological, physicochemical and physical analyses. Every 3 days the MP potatoes were fried and evaluated for moisture loss, oil absorption, instrumental texture and sensory evaluation. Packaging under atmospheric air was effective in reducing the mass loss of MP potatoes. The vacuum packaging was more effective for the MP product without edible coating, because they kept the pH, acidity, starch and sugar level more similar to the first day experiment, as well as low browning rate. The vacuum packaging, however, would not be appropriate when the purpose is frying, because this treatment showed the greatest loss of moisture and increased oil absorption. Packaging under argon atmosphere was also more effective for the MP product without edible coating, and it was an important factor to reduce CO2 levels inside the package, showed lower respiratory rate, lower browning index both before and after frying, reduced moisture loss during frying, kept fried product firmness better and also minimized oil absorption from the 3rd day of storage. The use of edible coating was effective in reducing the respiration of MP product until the 6rd day. For the fried product, the use of coating was a determining factor for moisture retention during frying of potatoes, and also to decrease oil absorption along the potato storage.
29

Corrosão de silício por jato de plasma em expansão no vácuo.

Leandro Leite Tezani 02 June 2010 (has links)
Este trabalho explora a implementação, caracterização e aplicação de um reator constritivo para geração de um jato de plasma de hexafluoreto de enxofre (SF6) operado em alto vácuo para corrosão de silício. Este sistema possibilita uma alta fragmentação do gás de trabalho ocasionando em uma alta concentração de flúor atômico (F) no volume da descarga. Tal densidade de F foi medida com auxilio da técnica de espectroscopia ótica de emissão através do método de actinometria. As análises foram realizadas para diferentes fluxos de SF6 e suas misturas como os gases O2 e Ar e distâncias entre a fonte do jato de plasma e o porta substrato (1-10 cm), para valores fixos de pressão na câmara de expansão (3,2 mTorr), campo magnético (7,2 mT) e potência de radiofreqüência (150W). Estas análises visam o estabelecimento de condições ótimas de processo onde a concentração de F é máxima. Posteriormente as amostras de Si foram corroídas e caracterizadas quanto a taxa de corrosão, anisotropia, uniformidade e rugosidade através do uso das técnicas de microscopia eletrônica de varredura e perfilometria óptica. Os resultados obtidos pela espectroscopia óptica indicaram altas intensidade de flúor para os plasmas gerados com as misturas de gases SF6/O2 e SF6/Ar para distancia de 1 cm, sendo que a mistura SF6/O2 produziu valores mais elevados, da ordem de 1.4x103 u.a. Através do método de actinometria foi determinada a densidade de F que variou de (0,6 - 2,5) x 1019 m-3 (correspondente a 6-25% do volume total dos gases na descarga) para os parâmetros de plasma investigados. Este resultado é comparável com as tecnologias atuais de corrosão como o ICP. As análises de perfilometria indicaram altas taxas de corrosão, que variaram de (0,2-1,4) m/min. possibilitando uma profundidade de corrosão igual a 10 m para algumas condições em um tempo de aproximadamente 7 minutos, tempo bem abaixo dos registrado em corrosões de Si com reatores convencionais como o RIE. As análises também indicaram bons valores de anisotropia (>0,85), boa uniformidade (0,01-0,14) e baixa rugosidade (25-372) utilizando-se plasmas de SF6/O2. Tais características não foram alcançadas com a mistura de Ar no plasma de SF6.
30

Estudo experimental da expansão de vapor gerado pelo bombardeamento de um alvo sólido de urânio metálico por canhão de elétrons.

Getúlio de Vasconcelos 00 December 1997 (has links)
No processo atômico de separação isotópica via laseres, o vapor de urânio metálico é gerado pelo aquecimento de um alvo sólido por um feixe de elétrons e iluminado por feixes de laseres, de modo a promover a ionização seletiva do 235U. Posteriormente, estes íons são coletados usando-se um campo eletrostático. O objetivo desta dissertação de Mestrado é o estudo experimental dos processos de geração e expansão do vapor de urânio, visando ajudar a tornar mais eficiente o processo de separação isotópica. Evaporou-se urânio metálico e medidas de fluxos de vapor foram realizadas em função da temperatura da superfície emissora e do ângulo normal a esta superfície. Através de três diferentes técnicas (transmitância de luz, balança analítica e espectroscopia alfa), analisou-se a massa depositada nos coletores. Os resultados obtidos foram ajustados segundo uma função de distribuição e comparados a valores teoricamente previstos.

Page generated in 0.0416 seconds