• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 14
  • 10
  • 9
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

MENSURAÇÃO DE ÁREA DE ÚLCERAS VENOSAS POR MEIO DOS SOFTWARES AUTOCAD® E IMAGE TOOL: REPRODUTIBILIDADE DE MÉTODOS / MEASUREMENT OF VENOUS ULCERS AREA USING THE SOFTWARES AUTOCAD® AND IMAGE TOOL: REPRODUCIBILITY OF METHODS

Eberhardt, Thaís Dresch 21 January 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The wounds measurement is an important factor in the evaluation healing because it provides parameters that indicate the progress of wound healing. The objective is to compare the area measured of venous ulcers through AutoCAD® and Image Tool software. The assessment of wound measurement methods is constituted as a gap in the knowledge produced by Brazilian nursing and as one of the fundamental aspects of the wounds evaluation. It is an evaluative analysis of reproducibility tests with a quantitative approach. The study included patients with venous ulcers treated at an outpatient clinic during the data collection period (March-July 2015), higher the age of 18 years with cognitive and verbal skills preserved, which had ulcers covering one side of the lower limb (n=21). For the data collection procedure, nurses that participated of the Skin Injury Study Group were contributors of research, being called evaluators. Each patient had his ulcer photographed by the researcher and by an evaluator with Cam Fujufilm Finepix S 14 Mega pixels. The photographs were transferred to the personal researcher's notebook, both the evaluator and the researcher carried out the measurements of the two photographs, with the two softwares. For the analysis of data mean and standard error, Wilcoxon test, intraclass correlation coefficient and concordance correlation coefficient were used, in addition to Bland and Altman procedure. The ethical precepts were based on Resolution No. 466/2012. 21 individuals participated in the study, who presented a total of 36 venous ulcers (72 photos). The average age of participants was 60.9, the majority of subjects were male, had one venous ulcer, with 3,0 years median time of existence of injury. The size of the ulcers had great amplitude. There was difference between the measurements of the researcher and the evaluators in AutoCAD® software, with no difference in the Image tool. However, the values of the correlation coefficients were strong in both cases. There was no significant difference between the measurements in both softwares, there is strong intraclass correlation and agreement between both, which seem to be more accurate in measuring wounds with an area> 10 cm². Measurements in AutoCAD and Image Tool softwares feature intraclass correlation and strong concordance, so they are reproducible. Still they appears to be more accurate when used to measure wound area> 10 cm². Therefore, the use of both is suitable for the measurement of venous ulcers with an area> 10 cm². / A mensuração de feridas é um dado importante no processo de avaliação da cicatrização porque fornece parâmetros que indicam a evolução da cicatrização da ferida. O objetivo é comparar a mensuração de área de úlceras venosas por meio dos softwares AutoCAD® e Image Tool. A avaliação de métodos de mensuração de feridas constitui-se como uma lacuna no conhecimento produzido pela enfermagem brasileira e como um dos aspectos fundamentais da avaliação de feridas. Trata-se de uma pesquisa de avaliação de reprodutibilidade de testes, com abordagem quantitativa. Participaram do estudo os pacientes portadores de úlceras venosas, atendidos em um ambulatório no período de coleta de dados (março a julho de 2015), com idade superior a 18 anos, com capacidade cognitiva e verbal preservadas, que possuíam úlceras cobrindo uma face do membro inferior (n=21). Para o procedimento de coleta de dados, os enfermeiros participantes do Grupo de Estudos de Lesões de Pele foram colaboradores da pesquisa, sendo denominados de avaliadores. Cada paciente teve sua úlcera fotografada pelo pesquisador e por um avaliador com Câmera Fujufilm Finepix S 14 Mega pixels. As fotografias foram transferidas para o notebook pessoal do pesquisador, tanto o avaliador quanto o pesquisador realizaram as mensurações das duas fotografias, com os dois softwares. Para a análise dos dados foram utilizados média e erro padrão, teste de Wilcoxon, Coeficiente de Correlação Intraclasse e Coeficiente de Correlação de Concordância, além do procedimento de Bland e Altman. Os preceitos éticos foram baseados na Resolução nº 466/2012. Participaram do estudo 21 indivíduos, que apresentaram, no total, 36 úlceras venosas (72 fotografias). A idade média dos participantes foi de 60,9, a maioria dos indivíduos era do sexo masculino, apresentava uma úlcera venosa, com tempo mediano de existência da lesão de 3,0 anos. Os tamanhos das úlceras apresentaram grande amplitude. Observou-se diferença entre as mensurações da pesquisadora e dos avaliadores no software AutoCAD®, sem diferença no Image tool. Apesar disso, os valores dos coeficientes de correlação foram fortes em ambos os casos. Não foi observada diferença significativa entre as mensurações nos dois softwares, existe forte correlação intraclasse e de concordância entre os ambos, os quais parecem ser mais precisos na mensuração de feridas com área > 10 cm². As mensurações nos softwares AutoCAD® e Image Tool apresentam correlação intraclasse e concordância fortes, ou seja, são reprodutíveis. Ainda, parecem ser mais precisos quando utilizados para mensurar feridas com área > 10 cm². Portanto, o uso de ambos é indicado para a mensuração de úlceras venosas com área > 10 cm².
12

Uso de informações de saúde para suporte à decisão: uma metodologia focada no consumidor da informação / Use of health information for decision support: a methodology focused on consumer information

Azevedo, Luiz Fernando de Aguiar January 2009 (has links)
Made available in DSpace on 2011-05-04T12:36:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2009 / O objetivo deste trabalho é apresentar os passos necessários para a construção de data marts /data warehouses como uma solução para um ambiente de suporte à decisão. Seu foco não é, entretanto, o aprofundamento de cada uma das etapas deste método (uma vez que existe uma ampla literatura sobre o assunto), mas realçar a importância do envolvimento do usuário aqui denominado consumidor da informação durante o processo de criação e manutenção destes data marts / data warehouses. O consumidor da informação é chamado a participar de um plano integrado com os membros das áreas detentoras do conhecimento necessário para a construção destas soluções de suporte à decisão, incluindo a área de tecnologia da informação. A disseminação das informações contidas nestes bancos de dados para os diversos tipos de consumidores da informação(com diferentes recursos de hardware, software e humanos disponíveis), e sua aplicação no controle social, também são discutidas aqui. / The purpose of this work is to present the required steps for the construction of data marts / data warehouses as a solution for a decision support environment. However, its focus is not to go deeper in each of the steps of this method (since there is a broad literature about the subject), but to highlight the importance of the user – here called information consumer – engagement during the process of creating and maintaining these data marts / data warehouses. The information consumer is called to take part in an integrated plan together with the members of the areas who own the necessary knowledge to build these decision support solutions, including the information technology (IT) area. The spread of the informations contained in these databases to the different types of information consumers (with different hardware, software and human resources available), and its application in social control, is also discussed here.
13

Desenvolvimento de software para aplicação de escala de avaliação funcional de pessoas com distrofia muscular de Duchenne e testagem de usabilidade / Development of software for application of functional assessment scale for people with Duchenne muscular dystrophy and usability testing

Albuquerque, Priscila Santos 24 February 2014 (has links)
Devido à carência de avaliações para Distrofia Muscular de Duchenne (DMD), fisioterapeutas desenvolveram e testaram a confiabilidade da Functional Evaluation Duchenne Muscular Dystrophy (FES-DMD). Visando otimizar sua aplicação foi necessário um software. O objetivo deste estudo foi desenvolver e testar a usabilidade de software para aplicação da FES-DMD. Para desenvolver o software foi necessário um engenheiro, um programador e uma fisioterapeuta. Após finalização foi realizada avaliação técnica por cinco pareceristas e aplicado teste de usabilidade com quinze fisioterapeutas especialistas, para avaliar o uso do software na prática clínica e coletar o tempo de aplicação da FES-DMD. De acordo com as características exigidas o software foi desenvolvido com especificações: linguagem Visual Basic. Net, base de dados SQL Compact Server, Plataforma Windows XP sp3 ou superiores, Hardware de suporte, tela com resolução 1024X768 e formato do vídeo WMV/MP4. Estas permitem que o software tenha banco de dados seguro, cadastro de usuários, visualização de filmes, preenchimento da escala, cálculo do escore e geração de relatório. Como resultados, a avaliação técnica contribuiu com Layout e o teste de usabilidade mostrou que dez de quinze fisioterapeutas concordam fortemente que o software é usável na prática clínica, três concordam, enquanto que um discorda e outro discorda fortemente. Com relação ao tempo de aplicação, a FESDMD no software se mostrou mais rápida (p < 0.001). Foi possível desenvolver software para aplicação da FES-DMD. O instrumento promove ganho de tempo do fisioterapeuta, armazena dados e imagens de forma segura, gera relatórios e é usável na prática clínica / Due to the lack of reviews for Duchenne Muscular Dystrophy (DMD), physiotherapists have developed and tested a confiabiliade Functional Evaluation of Duchenne Muscular Dystrophy (FES-DMD). In order to optimize your application was necessary software. The aim of this study was to develop and test the usability of software for application of FES-DMD. To develop the necessary software was an engineer, a programmer and a physiotherapist. After finalizing technical evaluation was carried out for five referees and applied usability testing with fifteen physiotherapists experts to evaluate the use of software in clinical practice and collect the time of application of FES-DMD. According to the characteristics required software has been developed with specifications: Visual Basic language.Net, database SQL Server Compact Platform, Windows XP sp3 or higher, Hardware Support, 1024X768 screen resolution and video format WMV/MP4. These allow the software to be secure database, user registration, inhouse movies, completing the scale score calculation and reporting. As a result, the technical evaluation contributed Layout and usability test showed that ten fifteen physiotherapists strongly agree that the software is usable in clinical practice, three agree, while one disagreed and one strongly disagrees. Regarding the time of application, the FES- DMD in software is faster (p < 0.001). It was possible to develop software for the application of FES- DMD. The instrument promotes gain time physiotherapist, stores images and data securely, generate reports, and is usable in clinical practice
14

Desenvolvimento de software para aplicação de escala de avaliação funcional de pessoas com distrofia muscular de Duchenne e testagem de usabilidade / Development of software for application of functional assessment scale for people with Duchenne muscular dystrophy and usability testing

Priscila Santos Albuquerque 24 February 2014 (has links)
Devido à carência de avaliações para Distrofia Muscular de Duchenne (DMD), fisioterapeutas desenvolveram e testaram a confiabilidade da Functional Evaluation Duchenne Muscular Dystrophy (FES-DMD). Visando otimizar sua aplicação foi necessário um software. O objetivo deste estudo foi desenvolver e testar a usabilidade de software para aplicação da FES-DMD. Para desenvolver o software foi necessário um engenheiro, um programador e uma fisioterapeuta. Após finalização foi realizada avaliação técnica por cinco pareceristas e aplicado teste de usabilidade com quinze fisioterapeutas especialistas, para avaliar o uso do software na prática clínica e coletar o tempo de aplicação da FES-DMD. De acordo com as características exigidas o software foi desenvolvido com especificações: linguagem Visual Basic. Net, base de dados SQL Compact Server, Plataforma Windows XP sp3 ou superiores, Hardware de suporte, tela com resolução 1024X768 e formato do vídeo WMV/MP4. Estas permitem que o software tenha banco de dados seguro, cadastro de usuários, visualização de filmes, preenchimento da escala, cálculo do escore e geração de relatório. Como resultados, a avaliação técnica contribuiu com Layout e o teste de usabilidade mostrou que dez de quinze fisioterapeutas concordam fortemente que o software é usável na prática clínica, três concordam, enquanto que um discorda e outro discorda fortemente. Com relação ao tempo de aplicação, a FESDMD no software se mostrou mais rápida (p < 0.001). Foi possível desenvolver software para aplicação da FES-DMD. O instrumento promove ganho de tempo do fisioterapeuta, armazena dados e imagens de forma segura, gera relatórios e é usável na prática clínica / Due to the lack of reviews for Duchenne Muscular Dystrophy (DMD), physiotherapists have developed and tested a confiabiliade Functional Evaluation of Duchenne Muscular Dystrophy (FES-DMD). In order to optimize your application was necessary software. The aim of this study was to develop and test the usability of software for application of FES-DMD. To develop the necessary software was an engineer, a programmer and a physiotherapist. After finalizing technical evaluation was carried out for five referees and applied usability testing with fifteen physiotherapists experts to evaluate the use of software in clinical practice and collect the time of application of FES-DMD. According to the characteristics required software has been developed with specifications: Visual Basic language.Net, database SQL Server Compact Platform, Windows XP sp3 or higher, Hardware Support, 1024X768 screen resolution and video format WMV/MP4. These allow the software to be secure database, user registration, inhouse movies, completing the scale score calculation and reporting. As a result, the technical evaluation contributed Layout and usability test showed that ten fifteen physiotherapists strongly agree that the software is usable in clinical practice, three agree, while one disagreed and one strongly disagrees. Regarding the time of application, the FES- DMD in software is faster (p < 0.001). It was possible to develop software for the application of FES- DMD. The instrument promotes gain time physiotherapist, stores images and data securely, generate reports, and is usable in clinical practice

Page generated in 0.1292 seconds