• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 588
  • 10
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 607
  • 297
  • 202
  • 134
  • 84
  • 78
  • 74
  • 73
  • 68
  • 65
  • 63
  • 61
  • 58
  • 57
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Ventilação natural em edifícios de escritórios na cidade de São Paulo: limites e possibilidades do ponto de vista do conforto térmico / Natural ventilation in São Paulo office buildings: thermal comfort limits and possibilities

Figueiredo, Cíntia Mara de 10 April 2007 (has links)
Esta pesquisa avalia o potencial de utilização da ventilação natural em edifícios de escritórios na cidade de São Paulo do ponto de vista do conforto térmico. Como parte do trabalho, foi elaborado um modelo de um edifício de escritórios com características arquitetônicas e de ocupação semelhantes às existentes nestes edifícios atualmente em São Paulo. A pesquisa foi feita com simulações computacionais deste modelo. Primeiramente foram avaliadas as temperaturas internas. Uma área do modelo foi simulada no software EnergyPlus para as oito orientações solares principais, com objetivo de se estimar as temperaturas operativas médias horárias para todos os meses do ano. Os resultados foram analisados sob o enfoque da teoria adaptativa de conforto térmico, de acordo com o índice para ambientes ventilados naturalmente proposto pela norma Ashrae 55, 2004. Esta análise gerou o mapeamento dos períodos do ano onde o ambiente estaria confortável se forem considerados 90% ou 80% de usuários satisfeitos e quanto não estaria confortável, tanto por calor quanto por frio. Também foi feita uma avaliação do modelo, de caráter exploratório, com simulações em um software de dinâmica dos fluidos, o CFX. Estas simulações objetivaram estimar se a estratificação da temperatura ou as velocidades internas do ar poderiam gerar áreas localizadas de desconforto no ambiente. / This research evaluates the potential for the use of natural ventilation in São Paulo city office buildings from a thermal comfort viewpoint. As part of the work, a model was developed with architectural and occupational characteristics similar to the those of office buildings in São Paulo city. The research was carried out using computational simulations of this model. First internal temperatures were evaluated. An area of the model was simulated in EnergyPlus software for the eight main solar orientations, with the object of estimating the average operative temperature for all months of the year. The results were analyzed under the focus of the adaptive thermal comfort theory, according the index proposed in Ashrae Standard 55, 2004 for naturally ventilated environments. This analysis generated a mapping of the annual periods where this space would be comfortable for 90% or 80% satisfied users and when it would not be comfortable, either for warmth or for cold. An exploratory study of that model was done, using computational fluid dynamics with CFX software. The objective was to estimate if the temperature stratification and the internal air velocities could cause local areas of discomfort within this environment.
202

Análise experimental da influência do sistema de ventilação e distribuição de ar no conforto térmico e na dispersão e remoção de partí­culas expiratórias em cabine de aeronave. / Experimental analysis of the influence of the ventilation and air distribution system in the thermal comfort and in the dispersion and removal of expiratory particles in the aircraft cabin.

Fabichak Junior, Douglas 21 September 2018 (has links)
O conforto térmico e a dispersão e remoção de partículas em cabine de aeronave são função, fundamentalmente, do seu sistema de ventilação e distribuição de ar. Juntamente com a análise da influência do sistema de ventilação por mistura (MV), atualmente utilizado em aviões comerciais, no presente trabalho são propostos e analisados dois novos sistemas, o sistema de distribuição de ar pelo piso (UFAD) e o sistema de ventilação por deslocamento (DV). A análise experimental de condições de desconforto térmico local e de dispersão e remoção de partículas expiratórias foi realizada em um mock-up de uma aeronave comercial com 12 assentos, com 4 assentos por fileira. Os resultados mostram forte influência da temperatura do ar insuflado na cabine, de 18 °C e 22 °C, do ponto de geração de partículas na cabine, em assento junto à fuselagem e junto ao corredor, e da faixa de tamanhos de partículas, principalmente nas faixas de 2,0 a 3,0 µm e de 3,0 a 5,0 µm, de maior interesse no presente trabalho. Por fim, os resultados mostram que o sistema UFAD apresentou o melhor desempenho, tanto quanto ao desconforto térmico devido a correntes de ar, com valores abaixo de 20 % preconizado pelas normas ISO 7730 (2005) e ASHRAE 55 (2013), quanto à menor dispersão de partículas e maior eficiência na remoção de partículas na região de respiração, com eficiência na remoção de partículas maior em até 18,8 % em relação ao sistema DV e em até 41,6 % em relação ao sistema MV. O sistema DV apresentou resultados intermediários com relação ao desconforto térmico local, com pior resultado na região dos pés com média do desconforto térmico local de 22,7 % e muito boa eficiência na remoção de partículas em relação ao sistema convencional MV maior em até 32,0 %. O sistema MV apresentou as piores condições com relação ao desconforto térmico para a região da cabeça e dos pés, com média de pessoas insatisfeitas de até 25,7 %. O sistema MV também apresentou as piores condições com relação à eficiência de remoção de partículas com a maior quantidade total de partículas na região de respiração ao longo da aeronave. / Thermal comfort and particles dispersion and removal in an aircraft cabin depend, essentially, on its ventilation and air distribution system. Together with the analysis of the influence of the mixing ventilation system (MV), used in commercial aircrafts, in the present work two new systems are proposed and analyzed, the underfloor air distribution system (UFAD) and the displacement ventilation system (DV). Experimental analysis of local thermal discomfort conditions and dispersion and removal of expiratory particles was performed in a mock-up of a commercial 12 seat aircraft with 4 seats per row. The results show a strong influence of the temperature ot the air inflated into the cabin, of 18°C and 22°C, of the point of generation of particles in the cabin, at the seat next to the fuselage and near the corridor, and of the particle size range, mainly in the bands of 2.0 to 3.0 µm and 3.0 to 5.0 µm, of greater interest in the present study. Finally, the results show that the UFAD system presented the best performance, as well as the thermal discomfort due to drafts, with values below 20% recommended by ISO 7730 (2005) and ASHRAE 55 (2013), as well as the lower dispersion of particles and greater efficiency in the removal of particles in the respiratory region, with particle removal 18.8% in relation to the DV system and by up to 41.6% in relation to the MV system. The DV system presented intermediate results in relation to the local thermal discomfort, with worse results in the feet region with a mean of the local thermal discomfort of 22.7% and very good particle removal efficiency in relation to the conventional MV system of up to 32, 0%. The MV system presented the worst conditions in relation to the thermal discomfort for the head and feet region, with an unsatisfied average of up to 25.7%. The MV system also presented the worst conditions with respect to the removal efficiency of particles with the highest total amount of particles in the breathing region along the aircraft.
203

Análise numérica da influência de configurações de aberturas da fachada e do mobiliário na ventilação natural em ambientes de escritórios. / Numerical analysis of the influence of facade openings and furniture configurations on natural ventilation in office environments.

Mariana, Flávio Bomfim 19 April 2013 (has links)
Com a disseminação do conceito de desenvolvimento sustentável tem sido verificado um aumento no interesse por sistemas de baixo ou nenhum consumo de energia. Uma forma de diminuir o consumo e propiciar condições de qualidade do ar e conforto térmico é utilizar a ventilação natural. No presente trabalho analisa-se a influência de diferentes tipos de janelas e mobiliário sobre as condições de ventilação natural em ambientes de escritório utilizando simulação numérica. O modelo é composto por um edifício de cinco pavimentos, sendo analisadas as condições térmicas do pavimento mais alto. A mudança do mobiliário apresentou tendência de piora das condições de conforto com o aumento das partições, sendo significativa com partições de 1,50m de altura e as demais condições menos propícias para a ventilação natural. Não foi observada mudança significativa entre as partições de 0,90m e 1,10m, sendo preferível então a última pela melhor privacidade dos ocupantes. A modificação do layout não resultou em mudanças significativas de temperatura do ar no ambiente ocupado, salvo na configuração que reuniu as piores condições de ventilação. Já a geometria das janelas apresentou resultados significativamente diferentes, pois a janela maxim-ar permitiu a entrada de um volume maior de ar e o distribuiu melhor dentro dos ambientes de escritório simulados, em comparação com a janela de correr vertical. Verificou-se que a escolha adequada das janelas influencia o ambiente térmico de maneira semelhante à redução da iluminação e dos equipamentos que dissipam calor. Concluiu-se que com a implantação adequada da edificação, escolha correta das aberturas, da configuração do mobiliário e das cargas térmicas internas é possível utilizar sistemas de ventilação natural em ambientes de escritórios com bons resultados. Por fim, é importante destacar que a aplicação da dinâmica dos fluidos computacional (CFD) para ventilação natural é complexa, pois este fenômeno é naturalmente instável, com necessidade de bastante cuidado na definição dos modelos para representar o problema e no processo de simulação numérica. / Among the spread of the sustainability concept it has been found a rising interest on low or zero energy consumption systems. One approach to reduce energy consumption and also provide acceptable levels of indoor air quality and thermal comfort is using natural ventilation. On the present report it is analyzed the influence of different types of windows and furniture on natural ventilation conditions of office environments using numerical simulation. The model is a five storey building, being the thermal conditions evaluated in the highest floor. Furniture change presented a worsen tendency of the comfort conditions as the partitions height increased. This worsen was significant when 1.50m height partitions were combined with other features less propitious for natural ventilation. No significant change was found between the 0.90m and 1.10m height partitions, being the last preferable due to occupants privacy enhance. Layout modification did not result on significant changes of occupied zone air temperature, except on the set up that gathered the worse ventilation conditions. However, the different window geometries presented results significantly different, since the maxim-air window allowed the entrance of more wind and has distributed it better inside the simulated office environments. Therefore, thermal comfort conditions became better than in comparison with the vertical sliding windows. It was verified that the adequate choice of windows influences the thermal environment in a similar way to the reduction of lighting and equipments that dissipate heat. It was concluded that with the proper building implementation, correct choice of openings, furniture configuration and internal heat gains it is possible to use natural ventilation in office environments with good results. Finally, it is noteworthy the complexity in applying the computational fluid dynamics (CFD) for natural ventilation, since it is an inherently unstable phenomenon, requiring considerable care in defining the models to represent the problem and in the numerical simulation process.
204

Arquiteturas de distribuição de ar em cabines de aeronaves: análise experimental da dispersão de partículas expiratórias. / Air distribution architectures in aircraft cabins: experimental analysis of expiratory particles dispersion.

Fabichak Junior, Douglas 13 December 2013 (has links)
O sistema de distribuição de ar comumente utilizado em cabines de aeronaves consiste no insuflamento de ar na parte superior e retorno na parte inferior, com mistura do ar na cabine. Devido à sua característica de mistura, este sistema pode dispersar doenças infecciosas pelo ar na cabine. A eclosão mundial do vírus SARS (Severe Acute Respiratory Syndrome) em 2003 demonstrou que a disseminação de contaminantes aéreos ainda é um evento não controlável, uma vez que foi rapidamente difundido mundo afora, principalmente porque pessoas infectadas viajaram de avião para cidades distantes. Fatos como esses têm motivado governos, empresas e instituições de pesquisa a investirem fortemente em pesquisa e desenvolvimento. Novos sistemas de ventilação e distribuição de ar em aeronaves, baseados em sistemas de ventilação por deslocamento e de distribuição de ar pelo piso, estão começando a ser testados. Neste contexto, no presente trabalho foi realizada análise experimental da dispersão de partículas expiratórias em cabine de aeronave, considerando diferentes arquiteturas de distribuição de ar, em mock-up de 12 lugares, utilizando gerador e contadores de partículas. Os ensaios foram realizados para três arquiteturas de distribuição de ar: sistema de ventilação por mistura (MV), sistema de distribuição de ar pelo piso (UFAD) e sistema pelo piso modificado (UFAD modificado), com a mesma vazão de ar de insuflamento em duas condições de temperatura do ar insuflado na cabine: 18 e 22°C. E com geração de partículas em dois pontos da cabine: perto da fuselagem e perto do corredor. As partículas foram geradas e medidas na altura da zona de respiração, a 1,10 m do piso. Os resultados mostram que o ponto de geração de partículas, bem como a temperatura do ar insuflado na cabine, tem grande influência na dispersão e na concentração de partículas ao longo da cabine. Uma menor temperatura do ar na cabine favorece a formação de plumas térmicas junto aos passageiros, aumentando a eficiência na remoção de partículas da cabine. O sistema UFAD apresentou a menor dispersão e a maior eficiência na remoção de partículas expiratórias da cabine, mostrando-se promissor para utilização também em cabines de aeronaves. O aumento na remoção de partículas expiratórias de 3 a 5 m, do sistema UFAD com relação ao sistema convencional MV, foi de até 63,4%. / The air distribution system commonly used in aircraft cabins consists the air insufflations at the top of the cabin with return of the air at the bottom, with mixing air within the cabin. Due to this mixing characteristic, this system can disperse infectious diseases through the cabin air. The global outbreak of SARS virus (Severe Acute Respiratory Syndrome) in 2003 showed that the spread of airborne contaminants is still an uncontrollable event, since it was quickly spread around the world, mainly because infected people who traveled by plane to distant cities. Facts like these have motivated governments, companies and research institutions to invest heavily in research and development. New ventilation systems and air distribution aircraft based on displacement ventilation systems and underfloor air distribution are beginning to be tested. In this context, the present work was made an experimental analysis of the expiratory particles dispersion in aircraft cabins considering different air distribution architectures in a mock- up containing 12 seats, using a generator and a particle counter. The experiments were performed in three architectures air distribution: mixing ventilation system (MV), underfloor air distribution (UFAD) and the underfloor air distribution modified (UFAD modified), all of them with the same air supply rate, considering two air supply temperature conditions: 18 and 22°C. And particle generation at two points of the cabin: near the fuselage and near the aisle. The particles were generated and measured in the breathing zone, 1,10 m from the floor. The results show that the point of generation of particles, and the air supply temperature, have great influence on the dispersion and particle concentration throughout the cabin. A lower air temperature in the cab favors the formation of thermal plumes within the passengers, increasing the efficiency in removing particles from the cabin. The UFAD system had the lowest dispersion and greater efficiency in removing expiratory particles from the cabin, being promising also for its use in aircraft cabins. The increase in expiratory removal of particles from 3 to 5 microns UFAD system with respect to conventional MV was up to 63.4%.
205

Estudo da influência das manobras de recrutamento alveolar sobre a mecânica, a ventilação e o parênquima pulmonar durante lesão aguda promovida pela instilação de ácido clorídrico: estudo experimental em porcos / Influence of alveolar recruitment maneuvers on respiratory mechanics, ventilation and pulmonar parenchyma during acute lung injury caused by hydrocloric acid: experimental study in pigs

Aline Magalhães Ambrósio 28 January 2005 (has links)
Diversas estratégias de ventilação mecânica que estabelecem limites na pressão e volume intratorácicas têm sido propostas para pacientes com síndrome de angustia respiratória aguda (SARA). Estas recomendações são baseadas na observação de que a ventilação mecânica com volume corrente excessivo ou pressão positiva expiratória final (PEEP) insuficiente pode ocasionar lesões pulmonares graves, decorrentes de superdistensão de unidades alveolares. O objetivo do atual estudo foi aplicar manobras de recrutamento alveolar e PEEP em pulmões submetidos à lesão pulmonar aguda (LPA) através da administração de HCl . Foram utilizados 24 suínos Landrace - Largewhite, do sexo feminino, pesando entre 25 e 35 Kg. Após a anestesia os animais foram submetidos à ventilação com volume controlado (6 a 8 ml/Kg) e foram randomizados em 4 grupos: GI (6 animais não submetidos a LPA e tratados com PEEP progressivo de 5, 10, 15 e 20 cmH2O e regressivo de 20 a 5 cmH2O); GII (6 animais não submetidos a LPA e tratados com PEEP progressivo de 5, 10, 15 e 20 cmH2O e regressivo de 20 a 5 cmH2O associado a 3 manobras de recrutamento consecutivas, com pressão de 30 cmH2O antes de cada alteração do PEEP); GIII (6 animais submetidos a 1 hora de LPA por HCl e tratados como GI) e GIV (6 animais submetidos a 1 hora de LPA por HCl e tratados como GII). A mecânica respiratória e oxigenação foram avaliadas a cada 20 minutos, acompanhando cada alteração do PEEP. A LPA foi observada através de severas alterações na oxigenação e mecânica respiratória. A administração de MR associada a PEEP foi capaz de restaurar os valores controle, porém, os elevados valores de PEEP e CPAP foram acompanhados de significantes alterações hemodinâmicas quando comparadas com os animais que não foram submetidos a LPA. O derrecrutamento alveolar ocorreu provavelmente quando os valores de PEEP foram retornados para 5cmH2O. As lesões pulmonares foram uniformes nos animais que foram submetidos ao HCl, evidenciadas pela presença de necrose, hemorragia, congestão e infiltrado de células inflamatórias no interstício e nos alvéolos. O modelo experimental de lesão pulmonar aguda foi adequado para estudar MR seguidas por PEEP, pois apresentou importantes alterações dos valores de oxigenação e complacência, observado 1 hora após a instilação do HCl.Os valores de PEEP de 5cmH2O foram incapazes de manter o recrutamento no momento final do estudo, enquanto que os valores de PEEP de 10cmH2O foram suficientes para restabelecer a oxigenação com mínima alteração hemodinâmica. A complacência não melhorou após as manobras. Futuros estudos são necessários para confirmar os resultados obtidos, especialmente para mostrar que a manutenção do PEEP de 10cmH2O é suficientes para manter o recrutamento após as MR / Different mechanical ventilation strategies which define limits of intrathoracic pressures and volumes are being proposed for patients with acute respiratory distress syndrome (ARDS). These recommendations are based on observations that mechanical ventilation with excessive tidal volumes or insufficient values of positive end expiratory pressure (PEEP) can cause severe lung injury due to overinflation. The aim of the present study was to apply recruitment maneuvers (RM) and PEEP in lungs submitted to acute lung injury (ALI) due to the administration of hydrochloride acid. Twenty four female Landrace – Largewhite pigs, weighing 25 to 35 Kg were used. After anesthesia, animals were submitted to volume controlled mechanical ventilation (6 to 8ml/kg) and were randomly allocated in four groups of 6 animals each: GI animals without ALI and treated with progressive values of PEEP (5, 10, 15 and 20 cmH2O) or regressive (20 to 5 cm H2O); GII animals without ALI and treated with progressive values of PEEP (5, 10, 15 and 20 cmH2O) or regressive (20 to 5 cm H2O) plus 3 consecutive recruitment maneuvers with 30 cmH2O; GIII animals submitted to 1 hour of ALI and treated as GI; GIV animals submitted to 1 hour of ALI and treated as GII. Parameters of respiratory mechanics, ventilation and oxygenation were measured each 20 minutes according to the change of the PEEP values. ALI could be observed by the severe changes of oxygenation and respiratory mechanics noted. The use of RM and PEEP were able to restore control values. Nevertheless, application of high values of PEEP and CPAP were accompanied by significant hemodynamic changes which could be evidenced in animals without ALI. Derecruitment probably occurred when PEEP value reached 5 cmH2O. The lung lesions were uniform in the HCL-injured animals and consisted of necrosis, hemorrhage, congestion, and inflammatory cells infiltration that involved both the interstitium and the alveoli. The experimental model of lung injury was adequate to the study of RM followed by PEEP since significant changes of the oxygenation and compliance values could be observed 1 hour after acid instillation. PEEP values of 5cmH2O were incapable to maintain recruitment at the end of the observation period, while 10 cmH2O were sufficient to promote the reestablishment of oxygenation index with minimal hemodynamic changes. Compliance did not improve during the maneuvers. Further studies are necessary to confirm the results obtained, especially to show that the maintenance of a PEEP value of 10 cmH2O are sufficient to maintain recruitment after the RM
206

Simplified engine/nacelle heat transfer case analysis via CFD modeling for supporting the preliminary design of nacelle cooling/ventilation system.

Ricardo Pereira das Neves 06 November 2009 (has links)
An aeronautical engine is a complex machine composed of different components operating at different temperatures that in conjunction with the nacelle creates a crowded region with the coupled heat transfer mechanisms to be covered by the nacelle cooling/ventilation system. The final configuration of this system is defined through a demanding refinement of the preliminary design. For this reason the preliminary design is considered the key point and as a rule it can be based on the use of similar design scaling or by the use of numerical approaches. The numerical approaches available are the use of a one-dimensional heat transfer analysis or a complete heat transfer analysis via Computational Fluid Dynamics, or CFD. The short lead time usually available to get the nacelle ready leads the using of a more simplified analysis. Even though this simplified analysis is a lesser laborious activity than a more complete heat transfer analysis, it is still a relatively complicated task. Thus this work aims at presenting a simple methodology for supporting the preliminary design of nacelle cooling/ventilation which is basically relies on confirming if such system is really necessary taking into consideration the temperature distribution in the region between the engine/nacelle and the specified limits. In this case, the proposed methodology presented in this work is concerning to the natural convection analysis in a bidimensional engine/nacelle model by the use of CFD. In view of the fact that there is no specific literature reference available about such methodology or the natural convection analysis in an analogous model configuration or even experimental tests results, it was decided to utilize the studies about natural convection in concentric cylinders in the model validation process and to show the suitability of the proposed methodology, it was directly compared to the natural convection analysis in a simplified tridimensional engine/nacelle model by the use of CFD tool which would be performed by the manufacturer.
207

Análise de circuitos de descarga de ar pressurizado para ventilação de equipamentos em vôo.

Ronaldo Queiroz Macedo 31 October 2006 (has links)
Sistemas que operam com dissipação de calor e estão instalados na região pressurizada de uma aeronave podem requerer ventilação forçada, sendo necessário rejeitar este calor para fora da aeronave. A rejeição deste calor ée feita por sistema dedicado de ventilação, descarregando ar pressurizado através de alguma válvula controlada pelo sistema de pressurização, ou por uma tubulação com restrição de vazão, como venturi ou placa de orifício. Neste caso, a vazão deve ser limitada de tal forma que não prejudique a operação do sistema de pressurização, mas deve ser suficiente para ventilar os componentes que dissipam calor. Simulações de escoamento de ar pressurizado de aeronaves em estrangulamentos devem ser feitos considerando compressibilidade e a possibilidade de ocorrência de ondas de choque (escoamento sônico). Neste trabalho ée apresentado um modelo para cálculo de perda de carga em venturi e placa de orifícios, incluindo em condições de formação de onda de choque. O principal objetivo ée simular o sistema de ventilação de um Chiller, que ée composto por dutos, curvas, venturi e placa de orifícios, e estimar a vazão do sistema de ventilação em vôo, considerando compressibilidade e ondas de choque. Os resultados do modelo são próximos de resultados de ensaios em vôo, comparações feitas para diversas altitudes.
208

Fortaleza: terra do vento: a influência da mudança nos padrões de ocupação do solo sobre a ventilação natural em cidade de clima tropical úmido / Fortaleza, land of the wind: the influence of changing patterns of land occupation on natural ventilation in a tropical humid climate

Leite, Renan Cid Varela 03 December 2010 (has links)
A pesquisa propõe estudar a influência da alteração nos padrões de ocupação do solo sobre a ventilação natural, com estudo de caso em parte dos bairros Parque Iracema e Cambeba, na cidade de Fortaleza, Ceará. O vento é elemento chave à qualidade do ar no ambiente urbano e conforto térmico em localidades de clima quente úmido. Entretanto, este elemento do clima urbano é estruturalmente modificado pelo processo de urbanização. A morfologia urbana é resultado de prescrições edilícias tais como gabarito, taxa de ocupação do lote e recuos, modificando a permeabilidade do vento no espaço urbano. O estudo da alteração no escoamento do ar sobre o tecido urbano aborda, especificamente, o setor sudeste da capital cearense, que experimenta um processo de expansão urbana vinculado ao mercado imobiliário, intensificando a sua ocupação e alterando os padrões de uso do solo através da verticalização e do adensamento construtivo permitidos pela legislação urbana. O estudo reproduziu modelos virtuais representando a situação atual, a ocupação máxima permitida e uma proposta intermediária como crítica à permissividade prevista em lei. Os cenários foram simulados em ambiente de mecânica dos fluidos computadorizada. Os resultados indicaram o comprometimento das condições de ventilação na região posterior do cenário de máxima ocupação permitida pela elevação no gradiente de vento. No nível local a maioria dos pontos de comparação inseridos no modelo de máxima ocupação indicou melhores condições de ventilação na altura das edificações em relação ao modelo intermediário, resultado da diminuição da taxa de ocupação. / The research aims to study the influence of changing patterns of land use on natural ventilation, with a case study in a part of Parque Iracema and Cambeba neighborhood, in the city of Fortaleza, Ceará. The wind is a key element to air quality in the urban environment and thermal comfort in hot, humid climate locations. However, this urban climate element is structurally modified by the urbanization process. The urban morphology is the result of urban standards such building height, occupancy rate and space between buildings, changing the permeability of the wind in the urban space. The study of air flow changing over the urban area covers, specifically, the southeast sector of Fortaleza, which is experiencing an urban expansion process caused by the housing market, intensifying its occupation and changing patterns of land use through tall buildings and constructive densification allowed by law. The study reproduced virtual models representing the present situation, the maximum occupancy allowed and an intermediate proposal as a criticism of the permissiveness provided by law. These scenarios were simulated using fluid dynamics software. The results indicated that the natural ventilation was prejudiced in the posterior region of the scenario of maximum occupancy. At the local level most of the points of comparison within the maximum occupancy model indicated better ventilation conditions about buildings height comparing to the intermediate model, attesting the influence of a lower occupancy rate.
209

Avaliação de dois protocolos de desmame da ventilação mecânica em equinos / Evaluation of two protocols of weaning from mechanical ventilation in horses

Ida, Keila Kazue 11 June 2010 (has links)
O desmame é a transição da ventilação mecânica para a espontânea ao final da assistência ventilatória artificial. Não existem estudos específicos sobre esta fase de transição na espécie equina porém, os elevados valores na tensão de dióxido de carbono arterial (PaCO2) ao desmame e os baixos valores na tensão de oxigênio arterial (PaO2) na recuperação pós-anestésica (RPA) refletem a necessidade do estudo de modalidades mais seguras de desmame. Sendo assim, este estudo objetivou comparar dois diferentes protocolos de desmame da ventilação mecânica em equinos hígidos. Para tanto, foram utilizados 20 equinos, de 5±2 anos de idade e pesando 456±90 kg, submetidos a procedimento cirúrgico em decúbito dorsal. Os animais foram divididos aleatoriamente em 2 grupos de acordo com o protocolo de desmame, sendo considerado Grupo Controle os animais que foram submetidos a diminuição gradual da frequência respiratória (FR) isoladamente e Grupo PSV os animais que foram submetidos à redução da FR associada à administração de pressão de suporte ventilatório (PSV). Avaliou-se os parâmetros cardiovasculares, de ventilação, de oxigenação e metabólicos durante o desmame, a desconexão da ventilação mecânica e a RPA. Ao final do desmame, o Vexp (12,49±1,93 L) e o VT (28,10±6,17 mL/kg) do Grupo PSV foram superiores aos do Grupo Controle (Vexp de 7,66±2,66 L e VT de 16,88±4,30 mL/kg). Durante o desmame, a PaCO2 aumentou 29% (de 44±3 mmHg para 57±6 mmHg) e houve diminuição de 28% da relação PaO2/FiO2 (de 391±68 mmHg para 280±28) e de 9% da SaO2 (de 100±1% para 91±3%) apenas no Grupo Controle. Na RPA houve hipoxemia transitória no Grupo Controle após 15 (PaO2 de 48±5 mmHg) e 35 minutos (PaO2 de 57±7 mmHg) da desconexão do ventilador, e no Grupo PSV obteve-ve relação PaO2/FiO2 e SaO2 superior à do Grupo Controle durante a RPA. Concluiu-se que o uso da PSV no desmame foi capaz de manter os parâmetros ventilatórios e de oxigenação adequados durante todos os momentos de avaliação, e o desmame por redução gradativa da FR não impediu a ocorrência de hipercapnia transitória ao final do desmame e hipoxemia transitória na RPA. Considerando-se a higidez dos animais, estas alterações foram revertidas sem intervenção clínica, mas devem ser consideradas em animais debilitados. / Weaning from mechanical ventilation is the transition from mechanical to spontaneous ventilation at the end of the ventilatory support. There are no specific studies about this transition phase in horses. However, high tension of carbon dioxide pressure (PaCO2) at weaning and low values of arterial oxygen tension (PaO2) during recovery from anaesthesia suggest the need to study safer modalities of weaning. The scope of this study was to compare two weaning protocols from mechanical ventilation in healthy horses. With this purpose we studied 20 horses with a mean age of 5±2 years and a mean weight of 456±90 kg, scheduled to surgery in dorsal recumbency. Animals were randomly assigned one of the 2 weaning protocols, considering from Control Group those animals submitted to gradual decrease in respiratory rate (RR) set alone and from PSV Group those animals submitted to gradual decrease in RR associated with pressure support ventilation (PSV) administration. We evaluated cardiovascular, ventilatory, oxygenation and metabolic parameters during weaning, ventilator disconnection and recovery from anaesthesia. At the end of weaning, Vexp (12,49±1,93 L) and VT (28,10±6,17 mL/kg) of PSV Group were superior to the Control Group (Vexp of 7.66±2.66 L and VT of 16.88±4.30 mL/kg). During weaning PaCO2 increased by 29% (44±3 mmHg to 57±6 mmHg) and there was increasing PaO2/FiO2 ratio by 28% (391±68 mmHg to 280±28) and SaO2 by 9% (100±1% to 91±3%) only in Control Group. In the recovery phase there was transient hypoxemia in Control Group after 15 (PaO2 of 48±5 mmHg) and 35 minutes (PaO2 of 57±7 mmHg) of ventilator disconnection, and PaO2/FiO2 ratio and SaO2 in PSV Group were superior to the Control Group in the recovery phase. We conclude that the use of PSV in the weaning from mechanical ventilation phase was capable to remain ventilatory and oxygenation parameters appropriate in all evaluations, and weaning only by gradual decrease of RR did not prevent the occurrence of transient hypercapnia at the end of weaning and transient hypoxemia in the recovery from anaesthesia. Considering the healthiness of the animals, these changes were reversed without clinical intervention, but should be considered important recovery events in critical horses.
210

Estudo de um sistema de análise de preferências climáticas para animais convencionais de laboratório por tecnologia de ventilação microambiental e avaliações biológicas. I. Avaliação da eficiência de um protótipo, para o estudo de parâmetros ambientais, resultados parciais verificados em ratos (Rattus norvegicus) / A climatic chamber employing Intracage Ventilation System to evaluated house condition of laboraroty animals and to biological assays in thermoregulation studies. Partial evaluation in rats (Rattus norvegicus)

Chaguri, Luziane do Carmo Andrade Guinski 10 September 2009 (has links)
Projetos desenvolvidos para instalações de animais de laboratório adotam limites estreitos de ventilação e de climatização de ambientes a fim de assegurar um ambiente definido na sala de animais, denominada de macroambiente. Entretanto o tratamento do ar de uma sala não atinge, de forma eficiente, a gaiola em que o animal se encontra alojado (microambiente). O desenvolvimento de sistemas de ventilação microambiental (VMA), que possibilita um fluxo unidirecional de ar forçado para o interior das gaiolas dos animais; associado à modernas tecnologias de termoeletricidade, termosensores e termocontroladores permitem um acurado controle de variáveis climáticas em sistemas microambientais para roedores. No entanto, nota-se carência de dados no que se refere ao binômio temperatura e velocidade do ar para estes sistemas. O objetivo deste estudo foi o desenvolvimento de uma Câmera de Preferencia Climática (CPC) do tipo labiritno que permitisse analise da escolha de ambientes (binômio temperatura e velocidade do ar) para roedores de laboratório. O sistema de Ventilação Microambiental (VMA), possibilitou a climatização da CPC, que foi dividida em quatro sub-camaras, em temperaturas pré-determinadas de 22, 26, 30 e 34oC, todas à uma velocidade de ar de 0,3m/s. A CPC foi mantida numa sala climatizada a 18 ± 2 Co, por um sistema convencional de compressão do freon® para conforto humano. A massa de ar destinada a cada uma das sub-camaras era aquecida via resistência elétrica, controlada eletronicamente, para cada uma das temperaturas pré-determinadas. O comportamento exploratório dos ratos na CPC foi registrado pelo sistema de analise comportamental Ethovision Color-Pro 2.3® e analisado pelos parâmetros de tempo de permanência (Tp) (min.), freqüência de entrada (N) dos animais em cada sub-câmara climatizada e distancia percorrida (cm) dentro da CPC, em um período de 48 horas. Os testes físicos realizados com o equipamento mostraram que este foi capaz de manter as temperaturas pré-determinadas na faixa de &pludmn; 0,1 oC e velocidade de ar constante. Os resultados parciais da analise estatística do comportamento exploratório de ratos demonstraram que, no grupo controle, ou seja, onde as quatro sub-camaras estavam climatizadas em 22 Co, o Tp dos animais em cada uma das sub-camaras foi igual, evidenciando que as condições climáticas eram idênticas e portanto não houve preferência. No grupo experimental, ou seja, com as quatro camaras climatizadas em 22, 26, 30 e 34oC, aleatoriamente, o ratos demonstraram o maior Tp, ou seja, sua preferencia pelas menores temperaturas, 22 e 26oC; à despeito da velocidade de ar de 0,3 m/s, no interior das camaras.A CPC mostrou-se eficiente para estabelecer simulações do microambiente, em termos de preferência climática de roedores mantidos em laboratório. A CPC se mostra como um sistema eficiente também para estudos sobre a termoregulação em ensaios biológicos com animais, como os estudos de neurotoxinas do veneno de aranha Phoneutria nigriventer / Projects concerned with laboratory animals facilities usually adopt narrow range of ventilation and climatization variables to assure the define ambient. Such projects are concerned to the animal room (macro-environmental ambient) and this technology have a limitated operation to reach the micro-environmental (animal cages) ambients. The development of the intracage ventilation systems (ICV), which operating by an air influx inside the cages, beside the new technology on thermoelectric modules, thermosensitive and thermocontrolers materials, allows an accurate control of the microclimatic variables for animal enclosure. For this purpose we developed an experimental prototype, a climatic preference chamber (CPC) that allows to laboratory animal (e.g. rats) choose their preferred ambient under a different temperature conditionated chambers by the ICV thecnology, simulating the animal cage enclosure condition. That technology is characterized by delivery of air insufflation of 0.3 m/s, and regulated with differents temperatures in each chamber (22, 26, 30 and 34oC). The exploratory behavior of the rat at multiplechoise preference test was registered by Ethovision Color-Pro 2.3® system. This system allowed to the analysis of the climatic preference defined by the parameter time spent in different microclimates conditions. The analyses of the exploratory behavior demonstrated that rats spent much time in smaller temperature microclimates, as a 22 and 26 oC, indicating a preference for cooler ambients, in spite of the ICV air speed of 0,3m/s. The aim of this work is simulate laboratory animal housing condition to study the microclimate preference and also in termoregulation studies with laboratory rodents assays, like neurotoxins of the the spider Phoneutria nigriventer venom, that is an important tool to biochemical studies

Page generated in 0.038 seconds