• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 69
  • 12
  • 9
  • 6
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 302
  • 302
  • 302
  • 113
  • 81
  • 69
  • 57
  • 47
  • 39
  • 35
  • 34
  • 33
  • 30
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Characterization of Quarry By-Products as a Partial Replacement of Cement in Cementitious Composites

Nguyen, Tu-Nam N. 21 August 2023 (has links)
Concrete is the most widely used man-made material in the world. Its versatility, strength, and relative ease of construction allow it to be used in the majority of civil infrastructure. However, concrete production plays a significant role in greenhouse gas emissions, accounting for around 8% of CO2 emissions worldwide. This thesis aims to reduce the demand for cement in concrete construction, thus reducing the carbon footprint of the concrete, by focusing on classifying and determining the effectiveness of seven different quarry by-products as partial replacements of cement. Several methods were utilized in this study to characterize the quarry by-products: particle size distribution, helium pycnometry, X-Ray diffraction, X-Ray fluorescence, scanning electron microscopy, and a modified ASTM C1897 Method A that utilizes isothermal calorimetry and thermogravimetric analysis. These various methods allowed for the determination of the physical properties (e.g., gradation, specific gravity, and morphology) and the chemical properties (e.g., mineralogy and reactivity in a cementitious system). The quarry by-products were classified as four granites, two limestones, and one greenstone. These quarry by-products were found to be non-pozzolanic and non-hydraulic. However, there are indications that there may be reactions with the various clays and feldspars in the quarry by-products with calcium hydroxide, which suggests a degree of reactivity that is not necessarily pozzolanic or hydraulic. / Master of Science / Concrete is the most widely used man-made material in the world. Its versatility, strength, and relative ease of construction allow it to be used in the majority of civil infrastructure. However, concrete production plays a significant role in greenhouse gas emissions, accounting for around 8% of CO2 emissions worldwide. This thesis aims to reduce the demand for cement in concrete construction, thus reducing the carbon footprint of the concrete, by focusing on classifying and determining the effectiveness of seven different quarry by-products as partial replacements of cement. Several methods were utilized in this study to determine the physical properties (e.g., gradation, specific gravity, and morphology) and the chemical properties (e.g., mineralogy and reactivity in a cementitious solution) of the materials. The quarry by-products were classified as four granites, two limestones, and one greenstone. In general, these quarry by-products were not found to be reactive as a supplementary cementitious material, although the data may suggest some degree of reactivity between calcium hydroxide and the clays and/or feldspars in the quarry by-products.
252

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
253

Determinação de metais na bacia do rio Piracicaba usando as técnicas de Difusão em Filmes Finos por Gradiente de Concentração (DGT) e Fluorescência de Raios X Dispersiva em Energia (EDXRF) e por Reflexão Total (TXRF) / Determination of metals in Piracicaba river basin using Diffusive Gradients in Thin Films, and Energy Dispersive X-ray Fluorescence (EDXRF) and Total Reflection (TXRF) techniques

Almeida, Eduardo de 06 September 2011 (has links)
O desenvolvimento e aplicação de métodos analíticos na avaliação das concentrações de metais nas frações dissolvida e lábil na bacia do rio Piracicaba são de relevante importância para o estudo do comportamento químico-ambiental desses metais e para seu monitoramento, devido ao impacto das atividades antropogênicas nessa bacia. A técnica de difusão em filmes finos por gradiente de concentração (DGT, do inglês diffusive gradients in thin-films), é uma promissora ferramenta analítica de amostragem, pois permite pré-concentração, análise temporal, remoção de interferentes, avaliação lábil e amostragem in situ. A quantificação dos metais pelas técnicas de fluorescência de raios X dispersiva em energia por reflexão total (TXRF, total reflection X-ray fluorescence analysis) para amostras líquidas e da fluorescência de raios X dispersiva em energia (EDXRF, energy dispersive X-ray fluorescence) para amostras sólidas, mostram-se interessantes devido ao caráter multielementar, simultâneo e não destrutivo da análise. Neste trabalho avaliou-se a DGT para a determinação de Cr, Mn, Co, Ni, Cu, Zn e Pb em águas naturais, utilizando-se como agente ligante a membrana de celulose P 81 e como meio difusivo, o papel cromatográfico 3 MM. Calcularam-se os fatores de eluição e coeficientes de difusão para estes metais. Estudou-se o efeito da substância húmica, em diferentes concentrações, no desempenho da DGT para esses metais, e os resultados foram comparados e concordantes com as frações livre e a ligada à matéria orgânica, calculadas pelo programa Visual MINTEQ. Compararam-se o agente ligante e o meio difusivo à base de celulose, utilizados neste trabalho, com os à base de gel de poliacrilamida, empregando-se o complexante Chelex-100. Avaliou-se a homogeneidade da retenção dos analitos e do grupo ligante fosfato sobre a superfície do agente ligante. Nesses ensaios utilizaram-se soluções sintéticas contendo os analitos em pH 5,5 e força iônica 0,05 mol L-1 (ajustados com NaNO3). As determinações foram realizadas por TXRF e EDXRF. Avaliaram-se os acoplamentos DGT-SRTXRF e da DGT-EDXRF para a determinação da fração lábil de Cr, Mn, Co, Ni, Cu, Zn e Pb em amostras de água da bacia do rio Piracicaba, através de imersão em laboratório e in situ. Esses resultados foram comparados com as concentrações dissolvidas desses metais determinados pela técnica de fluorescência de raios X por reflexão total com excitação por luz síncrotron (SRTXRF, synchrotron radiation total reflection X-ray analysis). Os valores de concentrações de Mn, Cu e Zn nas frações dissolvida e lábil foram comparados com os valores máximos estabelecidos pela legislação brasileira Nas amostragens in situ, nos cinco pontos de coleta, as concentrações de Mn dissolvido e lábil foram maiores que a concentração total máxima permitida para esse elemento. Os elmentos Cr, Co, Ni e Pb, nas amostras coletadas, apresentaram-se abaixo do limite de detecção das técnicas SRTXRF (dissolvido), DGT-SRTXRF (lábil) e DGT-EDXRF (lábil). Os limites de detecção para o Cr, Mn, Co, Ni, Cu, Zn e Pb foram de 2,2 a 10 \'mü\'g L-1 na SRTXRF, de 0,21 a 3,6 \'mü\'g L-1 e de 7,2 a 24 \'mü\'g L-1 na DGT-SRTXRF e DGT-EDXRF, respectivamente / Analytical methods evaluation for metal dissolved and labile fractions determination in Piracicaba river basin is notable for metal-behavior studies in this environment as well as their monitoring due to anthropogenic activities. The diffusive gradients in thin films (DGT) is a promising sampling technique because of its pre-concentration, time-integrated, matrix interference removal, labile evaluation and in situ analytical features. The analytical techniques total reflection X-ray fluorescence (TXRF) for liquid samples and energy dispersive X-ray fluorescence (EDXRF) for solid samples analysis are advantageous due to simultaneous, multielemental and non-destructive characteristics. In this work, it was evaluated the DGT technique for Cr, Mn, Co, Ni, Cu, Zn and Pb determination in freshwater, using P 81 cellulose membrane as bind agent and 3 MM chromatographic paper as diffusive layer. Elution factors and diffusion coefficients were calculated for these metals. The humic acids effect on DGT performance was assessed and compared to free and humic acid bound metal fractions estimated by Visual MINTEQ software, in which agreement results were found. The paper-based DGT and gel-based one with Chelex-100 as bind agent were compared. The metal retention and phosphate group homogenization on P 81 membrane bind agent surface was studied. For these tests it was utilized a synthetic solution these metals containing with pH and ionic strength adjust to 5.5 and 0.05 mol L-1 (NaNO3), respectively. It was used the TXRF and EDXRF techniques for these metal quantifications. The DGT-SRTXRF and DGT-EDXRF were assessed in order to determine Cr, Mn, Co, Ni, Cu, Zn and Pb labile fractions in batch and in situ in Piracicaba river basin freshwater samples. These results were compared to their dissolved fractions by synchrotron radiation total reflection X-ray analysis, SRTXRF. The dissolved and labile Mn, Cu and Zn concentrations levels were compared to maximum allowed set by Brazilian legislation. The dissolved and labile Mn concentrations were higher than the maximum allowed in all five samples in situ sampling. Cr, Co, Ni, and Pb concentrations were lower than their limits of detection for dissolved fractions (SRTXRF) and labile ones (DGT-SRTXRF and DGT-EDXRF). The detection limits for Cr, Mn, Co, Ni, Cu, Zn and Pb were from 2.2 to 10 \'mü\'g L-1 for SRTXRF, from 0.21 to 3.6 \'mü\'g L-1 and from 7.2 to 24 \'mü\'g L-1 for DGT-SRTXRF and DGT-EDXRF, respectively
254

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
255

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
256

Determinação de metais na bacia do rio Piracicaba usando as técnicas de Difusão em Filmes Finos por Gradiente de Concentração (DGT) e Fluorescência de Raios X Dispersiva em Energia (EDXRF) e por Reflexão Total (TXRF) / Determination of metals in Piracicaba river basin using Diffusive Gradients in Thin Films, and Energy Dispersive X-ray Fluorescence (EDXRF) and Total Reflection (TXRF) techniques

Eduardo de Almeida 06 September 2011 (has links)
O desenvolvimento e aplicação de métodos analíticos na avaliação das concentrações de metais nas frações dissolvida e lábil na bacia do rio Piracicaba são de relevante importância para o estudo do comportamento químico-ambiental desses metais e para seu monitoramento, devido ao impacto das atividades antropogênicas nessa bacia. A técnica de difusão em filmes finos por gradiente de concentração (DGT, do inglês diffusive gradients in thin-films), é uma promissora ferramenta analítica de amostragem, pois permite pré-concentração, análise temporal, remoção de interferentes, avaliação lábil e amostragem in situ. A quantificação dos metais pelas técnicas de fluorescência de raios X dispersiva em energia por reflexão total (TXRF, total reflection X-ray fluorescence analysis) para amostras líquidas e da fluorescência de raios X dispersiva em energia (EDXRF, energy dispersive X-ray fluorescence) para amostras sólidas, mostram-se interessantes devido ao caráter multielementar, simultâneo e não destrutivo da análise. Neste trabalho avaliou-se a DGT para a determinação de Cr, Mn, Co, Ni, Cu, Zn e Pb em águas naturais, utilizando-se como agente ligante a membrana de celulose P 81 e como meio difusivo, o papel cromatográfico 3 MM. Calcularam-se os fatores de eluição e coeficientes de difusão para estes metais. Estudou-se o efeito da substância húmica, em diferentes concentrações, no desempenho da DGT para esses metais, e os resultados foram comparados e concordantes com as frações livre e a ligada à matéria orgânica, calculadas pelo programa Visual MINTEQ. Compararam-se o agente ligante e o meio difusivo à base de celulose, utilizados neste trabalho, com os à base de gel de poliacrilamida, empregando-se o complexante Chelex-100. Avaliou-se a homogeneidade da retenção dos analitos e do grupo ligante fosfato sobre a superfície do agente ligante. Nesses ensaios utilizaram-se soluções sintéticas contendo os analitos em pH 5,5 e força iônica 0,05 mol L-1 (ajustados com NaNO3). As determinações foram realizadas por TXRF e EDXRF. Avaliaram-se os acoplamentos DGT-SRTXRF e da DGT-EDXRF para a determinação da fração lábil de Cr, Mn, Co, Ni, Cu, Zn e Pb em amostras de água da bacia do rio Piracicaba, através de imersão em laboratório e in situ. Esses resultados foram comparados com as concentrações dissolvidas desses metais determinados pela técnica de fluorescência de raios X por reflexão total com excitação por luz síncrotron (SRTXRF, synchrotron radiation total reflection X-ray analysis). Os valores de concentrações de Mn, Cu e Zn nas frações dissolvida e lábil foram comparados com os valores máximos estabelecidos pela legislação brasileira Nas amostragens in situ, nos cinco pontos de coleta, as concentrações de Mn dissolvido e lábil foram maiores que a concentração total máxima permitida para esse elemento. Os elmentos Cr, Co, Ni e Pb, nas amostras coletadas, apresentaram-se abaixo do limite de detecção das técnicas SRTXRF (dissolvido), DGT-SRTXRF (lábil) e DGT-EDXRF (lábil). Os limites de detecção para o Cr, Mn, Co, Ni, Cu, Zn e Pb foram de 2,2 a 10 \'mü\'g L-1 na SRTXRF, de 0,21 a 3,6 \'mü\'g L-1 e de 7,2 a 24 \'mü\'g L-1 na DGT-SRTXRF e DGT-EDXRF, respectivamente / Analytical methods evaluation for metal dissolved and labile fractions determination in Piracicaba river basin is notable for metal-behavior studies in this environment as well as their monitoring due to anthropogenic activities. The diffusive gradients in thin films (DGT) is a promising sampling technique because of its pre-concentration, time-integrated, matrix interference removal, labile evaluation and in situ analytical features. The analytical techniques total reflection X-ray fluorescence (TXRF) for liquid samples and energy dispersive X-ray fluorescence (EDXRF) for solid samples analysis are advantageous due to simultaneous, multielemental and non-destructive characteristics. In this work, it was evaluated the DGT technique for Cr, Mn, Co, Ni, Cu, Zn and Pb determination in freshwater, using P 81 cellulose membrane as bind agent and 3 MM chromatographic paper as diffusive layer. Elution factors and diffusion coefficients were calculated for these metals. The humic acids effect on DGT performance was assessed and compared to free and humic acid bound metal fractions estimated by Visual MINTEQ software, in which agreement results were found. The paper-based DGT and gel-based one with Chelex-100 as bind agent were compared. The metal retention and phosphate group homogenization on P 81 membrane bind agent surface was studied. For these tests it was utilized a synthetic solution these metals containing with pH and ionic strength adjust to 5.5 and 0.05 mol L-1 (NaNO3), respectively. It was used the TXRF and EDXRF techniques for these metal quantifications. The DGT-SRTXRF and DGT-EDXRF were assessed in order to determine Cr, Mn, Co, Ni, Cu, Zn and Pb labile fractions in batch and in situ in Piracicaba river basin freshwater samples. These results were compared to their dissolved fractions by synchrotron radiation total reflection X-ray analysis, SRTXRF. The dissolved and labile Mn, Cu and Zn concentrations levels were compared to maximum allowed set by Brazilian legislation. The dissolved and labile Mn concentrations were higher than the maximum allowed in all five samples in situ sampling. Cr, Co, Ni, and Pb concentrations were lower than their limits of detection for dissolved fractions (SRTXRF) and labile ones (DGT-SRTXRF and DGT-EDXRF). The detection limits for Cr, Mn, Co, Ni, Cu, Zn and Pb were from 2.2 to 10 \'mü\'g L-1 for SRTXRF, from 0.21 to 3.6 \'mü\'g L-1 and from 7.2 to 24 \'mü\'g L-1 for DGT-SRTXRF and DGT-EDXRF, respectively
257

Preliminary Assessment: Identification of Chinese Drywall and Exposure to Particulate Matter and Metals during Cutting and Installation of Drywall

Karap, Vandana 20 May 2011 (has links)
Drywall, a popular building material made of gypsum based plaster sandwiched between two thick sheets of paper is used for building interior walls, is speedier alternative to traditional plaster, decreasing time and labor for construction. Importance of drywall increased with the demand for drywall after nine hurricanes hit Florida in 2004-05 and widespread damage caused in the Gulf Coast after Katrina in 2005. This study has two parts. First part presents an analysis of metals like strontium for the identification of Chinese drywall, and a comparison of strontium concentrations of American drywall and Chinese drywall using XRF (X-Ray Fluorescence) analysis with the Innov-X XRF analyzer. The second part presents an analysis of metal exposure during cutting and installation of drywall using 8stage Cascade impactor. The work space concentration of, different metals is analyzed using XRF analysis and particulate matter within various size ranges, were calculated and their effects are studied.
258

Recycling of Passenger Vehicles: A framework for upcycling and required enabling technologies

Kelly, Sean Michael 25 April 2018 (has links)
The automotive industry is expected to transition from a net-consumer to a net-producer of aluminum scrap as aluminum-intensive vehicles (AIVs, i.e., Ford’s aluminum-bodied F-150) begin to reach end-of-life (EOL). In the past, the industry has downcycled aluminum scrap to meet the consumption demands of the automotive sector. With the shift to having a large supply of this scrap in the near future, the industry needs to recover and reuse EOL Al by utilizing a circular economic model, create value via an upcycling paradigm (vs downcycling). This work establishes a platform as to how the recycling industry can be restructured to create value in our waste streams and is organized in three segments: First, an analysis of the flow of automobiles at EOL was carried out from the perspective of recovery and reuse; a recycling rate for Al has been determined, and the factors that go into the dynamics of the recycling rate have been identified. Secondly, the current state of the market was surveyed to evaluate where improvements could be made to affect material collection and recovery. The latter led to compositional characterization of aluminum auto-shred to identify the alloys in the mixture, and thereby the needed intelligent sorting systems for upcycling. Thirdly, these results were used in a dynamic material flow model to predict how the composition of auto-shred will change due to increased aluminum usage and as a function of various end-of-life processing scenarios. The outcome and impact of this work is that we have established a platform that enables the ELV recycling industry to upcycle the large amount of Al that will be available in the near future. These results will be discussed and reviewed during this presentation.
259

Caracterização de pinturas do artista Alfredo Volpi por meio de métodos não destrutivos: espectrofotômetro, EDXRF, MEV e imageamento multiespectral / Characterization of the artist Alfredo Volpi\'s paintings by non-destructiva methods: spectrophotometer, EDXRF, SEM and multispectral imaging

Mori, Eva Kaiser 02 September 2015 (has links)
Alfredo Volpi (1896 - 1988) é um dos mais importantes pintores brasileiros contemporâneos. Sua extensa obra foi marcada, principalmente, por composições cromáticas e abstrações geométricas. Foi um artista que dava importância muito grande à técnica e aos materiais, tendo desenvolvido uma maneira própria e sistemática de trabalhar: confeccionava suas próprias telas, tintas e até pigmentos, com terras naturais. Analisou-se ao todo 11 pinturas a têmpera em diversos suportes (tela, aglomerado de madeira e mural), 10 delas realizadas na década de 1950, período em que a obra do artista passou por uma grande transformação, do figurativismo ao abstracionismo e do uso de tintas industriais à base de óleo para a técnica medieval da têmpera. As características de opacidade, saturação cromática e presença material do pigmento sobre a superfície da tela, inerentes a esta técnica pictórica, tornam-se elementos tão importantes em sua obra, quanto o uso da cor na formação do espaço. Foram realizados estudos de cor e composição química dos materiais e levantamentos de informações sobre seus procedimentos técnico-artísticos a partir de métodos analíticos complementares não destrutivos e pesquisa em diversas fontes, pois entende-se que estes elementos são chaves importantes para o entendimento mais profundo de sua obra. O espectrofotômetro foi utilizado para medição da cor com base em curvas espectrais e coordenadas numéricas de referência dentro de um espaço de cor uniforme. Técnicas de imageamento por luz visível, fluorescência visível por radiação ultravioleta e reflectografia de infravermelho próximo foram utilizadas para levantar informações sobre o processo criativo do artista, detectar locais de intervenções de restauro e observar o grau de fluorescência de cada área cromática das pinturas como auxiliar na identificação de pigmentos. A técnica de EDXRF (Espectroscopia de Fluorescência de Raios X por Energia Dispersiva) foi importante para caracterização química dos materiais. O MEV-EDS (Microscópio Eletrônico de Varredura com Espectroscopia por Dispersão de Energia de Raios X) forneceu informações sobre composição química e imagens da superfície dos materiais presentes nas pinturas murais. A partir da integração destas informações pôde-se identificar uma parte da rica paleta deste pintor, documentar as cores das pinturas no presente, identificar ou dar indicações da composição dos pigmentos e da base de preparação das pinturas e iluminar partes da história de cada uma das obras, como presença de esboços feitos à grafite, pinturas anteriores encobertas, pinceladas e maneiras de misturar a tinta e documentar seu estado atual de conservação. As ferramentas utilizadas se mostraram úteis na caracterização das pinturas, revelaram informações inéditas sobre a obra deste artista e levantaram novas indagações. As informações obtidas podem ser o início de um banco de dados sobre sua obra. / Painter Alfredo Volpi (1896 - 1988) is one of the most important contemporary Brazilian artists. His extensive work, mostly characterised by chromatic compositions and geometric abstractions, is technically unique. The artist attributed great importance to craft and materials, developing his own systematic way of working. Among the paintings analysed were 11 temperasin various supports (canvas, hardboard panel and mortar). Of the selection, 10 paintings were made around 1950, when the artist\'s work underwent a major transformation, from figuration to abstraction, from the use of industrial oil-based paints to the medieval technique of tempera. This technique, known for its opacity, colour saturation and material presence of pigments on the canvas,became as important as the colour itself in the shaping of the artist\'s new spatial relation. It is understood that these elements are important keys to a deeper understanding of his work, both technically and artistically. The present investigation was carried out making use of non-destructive complementary analytical techniques. The aim was to study the chromatic and chemical composition characteristics of his paintings and gather information on the technical procedures the artist may have used. The spectrophotometer was used to measure the colour based on the spectral curves and numerical reference coordinates within a uniform colour space. Techniques of visual examination with visible light, visible fluorescence by ultraviolet radiation and near-infrared reflectography were used to gather information about the artist\'s creative process. These techniques also helped detect restoration patches and identify pigments. The EDXRF (Energy Dispersive X-Ray Fluorescence) technique was important for chemical characterization of materials, while the SEM-EDS (Scanning Electron Microscope with Energy Dispersive X-Ray Spectroscopy) provided surface images and information on the chemical composition of the material present in the murals. From the integration of these techniques it was possible to identify a part of the rich palette of Volpi´s paintings; to document the present aspects of the colours; to recognize or give indications of pigment and ground compositions and to shed light on parts of each of the works background, such as the presence of graphite sketches, covered earlier paintings and brushstrokes as well as to document the current condition of the works under study. The tools used have proven useful in characterizing the paintings, revealing new information about the work of the artist and raising new questions. The information obtained may be the beginning of a database on his oeuvre.
260

Determinação da concentração de elementos químicos potencialmente tóxicos em aerossóis presentes no interior de uma pequena indústria de fundição de metais, utilizando amostrador temporal e a técnica de fluorescência de raios X / Toxic inorganic elements content in suspended particulate matter inside a small foundry plant by streaker sampler and energy dispersive X-ray fluorescence technique

Massoni, Paulo Rogério 09 March 2009 (has links)
Este trabalho foi desenvolvido objetivando a determinação e a avaliação dos perfis temporais da concentração de alguns elementos químicos potencialmente tóxicos presentes no material particulado em suspensão (MPS) no interior de uma pequena indústria de fundição de metais bronze, ferro e alumínio que, em concentrações elevadas, podem acarretar sérios riscos à saúde do trabalhador. Para isso foi utilizado um amostrador temporal de MPS, que coleta amostras de aerossóis em intervalo de tempo pré-programados, separando-os por tamanho: (a) fração fina ou respirável (partículas com diâmetro aerodinâmico menor que 2,5 m, MP2,5) e (b) fração grossa ou inalável (entre 2,5 a 10 m, MP10-2,5), durante todo o período do processo de fundição (da fusão à moldagem). As amostras coletadas, na forma de faixas (strips) sobre um filtro (fração fina) e sobre um impactador (fração grossa), foram analisadas pela técnica de fluorescência de raios X por dispersão de energia (EDXRF), utilizando na excitação um tubo de raios X com alvo de Mo e e na detecção dos raios X característicos um detector semicondutor de Si(Li) acoplado a um analisador de pulsos multicanal, interpretando-se posteriormente os espectros de raios X obtidos pelo aplicativo AXIL. Para algumas amostras também foi feita uma análise com microscópio eletrônico de varredura (SEM/EDS) para se conhecer a morfologia dos particulados. Deste modo foi possível determinar a concentração de elementos químicos potencialmente tóxicos presentes em um ambiente de uma pequena indústria de fundição de metais, mostrando que o momento mais crítico dessa atividade foi o da moldagem e também determinar a forma do MPS. Na fundição do bronze e ferro, as concentrações dos elementos Cr, Mn, Ni e Pb, principalmente na fração fina no momento de moldagem, mostraram-se muito superior aos limites recomendados pelas agências brasileira e norte-americana. Apesar de não haver limites recomendados para o elemento Zn, foi verificada uma alta concentração principalmente na concentração na fração fina, o mesmo sucedendo para o Cu. Com respeito a fundição de alumínio, foi observado altas concentrações principalmente de Zn e Cu, somente na fração fina, não ocorrendo na fração grossa. Pelos resultados obtidos pode-se concluir que os trabalhadores estão sujeitos a condições insalubres de trabalho nesse tipo de ambiente, aconselhando-se o uso permanente de equipamentos adequados de proteção visando de preferência a fração fina, assim como um monitoramento constante desses elementos químicos durante todas as etapas do processo de fundição, principalmente na de moldagem / The aim of this work was to evaluate the chemical concentration of some potentially toxic inorganic chemical elements and the time profiles in fine (PM2.5, particles up to 2.5 m) and coarse (PM2.5-10, particles from 2.5 to 10 m) suspended particulate matter (SPM) inside a small foundry plant - bronze, iron and aluminium -, in which at high concentrations turns a healthy concern. For these purpose, a rotating streaker airparticulate sampler for sampling during all day foundry activity was utilized. Fine SPM was collected on a filter and coarse SPM in turn by an impactor. The collected samples were analyzed by energy dispersive X-ray fluorescence (EDXRF) technique employing a Mo target tube in the excitation, and the detection was carried out through Si(Li) semiconductor detector coupled to multichannel analyser, deconvolutting the X-ray spectra with AXIL software help. It was also carried out particulated morphological analysis by scanning electron microscopy with energy dispersive X-ray spectrometer coupled (SEM/EDS). In this manner, the inorganic chemicals content were determined in the small foundry allowing concluding that the moulding step is the critical one taking into account the amount of pollutant released. During bronze and iron melting, the Cr, Mn, Ni and Pb contents in SPM were higher than allowed values by Brazilian and United States legislations. It was also verified a high Zn and Cu content, mainly in the fine suspended particulate matter, although these elements are not contemplated by national nor international laws. Thus, due to this unhealthy environmental working conditions inside the small foundry plant,a proper individual protection equipment is mandatory mainly for fine suspended particulate matter, and a constant air pollutant monitoring in foundry plants is demanded, mainly during the moulding step

Page generated in 0.0592 seconds